SERIES <strong>GSJ</strong>OptionsELECTRICIn this type of diffuser the adjustment of the supply air jet iscontrolled by means of a integral electric motor.The motor is two position and as such, can move the aircontrol vanes from vertical to horizontal and back in a directoperation. Units are supplied with a 24v AC/DC Belimomotor.PNEUMATICA pneumatic cylinder is utilised in this model to control theoperation of the air control vanes from vertical to horizontaland back in a direct operation. Pneumatic cylinders have twocompressed air supply connection ports for operationin both directions. Units can therefore control the direction ofthe supply air jet via an external pneumatic control system.Compressed air pressure of 1 Bar required to operate unit.Maximum pressure 1.5 Bar.PerformanceDataSelectionProcedureThe performance tables that are illustrated in this brochuregive tabulated performance data for each listed size ofdiffuser, together with their design. The figures given relateto Cooling, Ventilation and Heating applications and aregiven for both horizontal and vertical distribution ofconditioned air.References UsedPRESSURE: All pressures are in Pa N/m2THROW: The horizontal and verticaldistances for air streams are givenat both 0.5 and 0.25 m/s terminalvelocities and are based upon aceiling effect for horizontaldistribution and free field for verticaldistribution.SOUND: The NC values are peak values onthe NC curvesThe performance data for all Gilberts products is derivedusing a Gilberts plenum design and specification.Performance cannot be guaranteed where alternativeplenum designs are used.1. <strong>Adjustable</strong> <strong>Swirl</strong> <strong>Diffusers</strong> are mainly used in high ceilingair distribution systems where vertical projection of supplyair is required during the heating cycle and horizontalprojection of supply air during cooling.2. Try if possible to construct in plan an imaginary squareceiling grid. This will enable the designer to position eachdiffuser at each square centre so that horizontal airdistribution is even in all directions.3. Establish the design maximum supply to room airtemperature differential. Together with the supply airvolume per diffuser select a suitable sized unit to verticallyproject the supply air into the occupied zone.4. As this range of diffuser will automatically ormanually adjust the supply air stream jet a check must beArea to be Area served to be servedRecommendedRecommendedMaximumMaximumNC NC Levels LevelsSound Broadcasting Sound Broadcasting 15 15 - 20 - 20Recording Recording Studios, Studios TV TV(Audience (Audience Studios) Studios) 20 20 - 25 - 25Lecture Theatres, Lecture Theatres, Cinemas, Cinemas,Concert Halls, Concert Boardroom/ExHalls, Boardroom/ExOffices Lounge, Offices Lounge, Conference Room,Court Room, Conference Churches, Room,Court Room, Private Churches, Bedrooms 25 - 30Private Bedrooms 25 - 30Operating Theatres,Operating Hospital Theatres, Wards, Staff Room,Hospital Wards, Class Rooms, Staff Room, Ballroom,Class Rooms, Banquet Room, Library, Bank,Museum, Ballroom, Offices 30 - 40Banquet Room, Library, Bank,Museum, Restaurants, Offices Department Stores, 30 - 40Computer Suite, Washroom Toilet 35 - 40Restaurants, Department Stores,Computer Laundries, Suite, Washroom Kitchens, Toilet 35 - 40Swimming Pools, Sports Arena 40 - 45Laundries, Garage, Kitchens, Light EngineeringSwimming Workshop Pools, Sports Arena 40 45 - 45 - 50Garage, Light Heavy EngineeringWorkshop 50 - 65Workshop 45 - 50Heavy Engineering Workshop 50 - 65made to establish the horizontal projection during thecooling isothermal cycle against the distribution grid for thatdiffuser. Since these units are used for high ceilingapplications an overblow situation can be acceptable.5. Check pressure loss and NC levels from design chartsto confirm acceptability. Where an NC level of

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!