Installation instruction3. Please fix remote controller upper part intothe setup board attached to the surface of thewall, as the picture below, and then, connectwith setup board by pressing lower part.- Please connect not to make a gap at the remote controllerand setup boardʼs upper and lower, right and left part.When separating remote controller fromsetup board, as the picture below, afterinserting into the lower separating hole usingscrew driver and then, spinning clockwise,remote controller is separated.- There are two separating holes. Please individuallyseparate one at a time.- Please be careful not to damage the insidecomponents when separating.WallSideWallSide4. Please connect indoor unit and remote controller using connection cable.Please check if connector is normally connected.WallSideWallSideGroup control1. When installing more than 2units of air conditioner to onewired remote controller, pleaseconnect as the right figure.• If it is not event communicationindoor unit, set the unit as slave.• Check for event communicationthrough the product manual.GNDSignal wire12VInstallation instructionGNDSignal wireWhen controlling multiple indoor units with event communication function with one remotecontroller, you must change the master/slave setting from the indoor unit.- Indoor units, the master/slave configuration of the product after completion of indoor unit powerʻOFFʼ and then ʻONʼ the power after 1 minutes elapsed sign up.- For ceiling type cassette and duct product group, change the switch setting of the indoor PCB.ON1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8#3 switch OFF: Master(Factory default setting)- For wall-mount type and stand type product, change the master/slave setting with the wirelessremote controller. (Refer to wireless remote controller manual for detail)❈ When installing 2 remote controllers to one indoor unit with event communication function, setthe master/slave of the remote controller. (Refer to remote controller master/slave selection)When controlling the group, some functions excluding basic operation setting, fan levelMin/Mid/Max, remote controller lock setting and time setting may be limited.ON#3 switch ON: SlaveENGLISH6 <strong>New</strong> <strong>Wide</strong> <strong>Wired</strong> <strong>Remote</strong> <strong>Controller</strong>Connecting cableIndoorUnit side5. Please use extension cable if the distance between wired remote controller andindoor unit is more than 10m.CAUTIONWhen installing the wired remote controller, do not bury it in the wall.(It can cause damage in the temperature sensor.)Do not install the cable to be 50m or above.(It can cause communication error.)• When installing the extension cable, check the connecting direction of the connector of the remote controllerside and the product side for correct installation.• If you install the extension cable in the opposite direction, the connector will not be connected.• Specification of extension cable: 2547 1007 22# 2 core 3 shield 5 or above.2. When installing more than 2 wiredremote controllers to one airconditioner, please connect as theright picture.• When installing more than 2 units of wiredremote controller to one air conditioner, setone wired remote controller as master andthe others all as slaves, as shown in theright picture.• You cannot control the group as shown inthe right for some products.• Refer to the product manual for more detail.GNDSignal wire12VB Y RMASTERB Y RSLAVE• When controlling in groups, set the master/slaver of the remote controller. Refer toInstaller setting section on how to set master/slave for more detail.GNDSignal wire12VOwnerʼs & Installation Manual 7
Installation instructionInstaller Setting -How to enter installer settingCAUTIONInstaller setting mode is to set the detail function of the remote controller.If the installer setting mode is not set correctly, it can cause problems to the product, user injury orproperty damage. This must be set by an certificated installer, and any installation or change that iscarried out by a non-certificated person should be responsible for the results. In this case, free servicecannot be provided.1If pressing button long for 3 seconds,it enters into remote controller settersetup mode.- If pressing once shortly, it enters intouser setup mode. Please press morethan 3 seconds for sure.When you enter the setting mode2 initially, Function code is displayed onthe bottom of the LCD screen.Function Code• Some categories of the menu may not be displayed according to the function of theproduct, or the menu name may be different.Value1) General air-conditioner productInstallation instructionNo. Function Code Value1 Test Run 01 01:Set2 Address Setting 02 00~FF : Address 01:VeryLow 0 ~ 25502:Low3 E.S.P. Value 0303:Med04:HighFunction Code ESP step05:Very High01:Remo45ThermistorCeiling Height040502:Indoor03:2TH01:Med02:Low03:High6 Static Pressure 0604:Very High01:V-H02:F-H03:V-L04:F-L7 Master Setting 0700:Slave01:Master8 Override Setting 0800:Slave01:Master9 Dry Contact 0900:Auto-Off01:Auto-On10Release 3 Min.Delay10 01:Set11 Zone State 1101:Variable02:Fixed12Celsius00:Celsius12Fahrenheit Switching01:Fahrenheit(Optimized only for U.S.A)13 Zone Type 1300:Zone <strong>Controller</strong>01:Damper <strong>Controller</strong>14 Zone Number 14 02~04(Zone number)15 Plasma 2016 Electric heater 2100: Not Installed17 Humidifier 2201: Installed18 Elevation Grill 2319 Ventilation Kit 24ESP valueENGLISH❊ Some contents may not be displayed depending on the product function8 <strong>New</strong> <strong>Wide</strong> <strong>Wired</strong> <strong>Remote</strong> <strong>Controller</strong>Ownerʼs & Installation Manual 9