Installation instructionInstaller Setting -Ceiling Height SelectionThis function is to adjust FAN Airflow rate according to ceiling height (For ceiling type product)If pressing button long for 31 seconds, it enters into remotecontroller setter setup mode.- If pressing once shortly, it entersinto user setup mode. Please pressmore than 3 seconds for sure.2If moving to ceiling height selection menu bypressing button, it indicates as picturebelow.Installer Setting -Static Pressure Setting12Press button for 4 secondsto enter the installer settingmode until timer segmentdisplays “01:01”.Installation instructionThis function is applied to only duct type. Setting this in other cases will cause malfunction.If pressing button repeatedly, it moves tostatic pressure selection menu as picturebelow.ENGLISHSelect ceiling height value by pressing3 button. (01:Low, 02:Standard,03:High,3Select static pressure by pressingbutton.(01:V-H, 02:F-H, 03:V-L, 04:F-L)16 <strong>New</strong> <strong>Wide</strong> <strong>Wired</strong> <strong>Remote</strong> <strong>Controller</strong>45Function CodePressThermistor settingbutton to save.Pressing button will exit settings mode.❈ After setup, it automatically gets out ofsetup mode if there is no button input for25 seconds.❈ When exiting without pressing set button,the manipulated value is not reflected.Ceiling Height LevelDescription01 Low Decrease the indoor airflow rate 1 step from standard level02 Standard Set the indoor airflow rate as standard level03 High Increase indoor airflow rate 1 step from standard level04 Very high Increase indoor airflow rate 2 steps from standard level• Ceiling height setting is available only for some products.• Ceiling height of ʻVery highʼ function may not exist depending on the indoor unit.• Refer to the product manual for more details.45Function CodePressPressurebutton to save.Pressing button will exit settings mode.❈ After setup, it automatically gets out ofsetup mode if there is no button input for25 seconds.❈ When exiting without pressing set button,the manipulated value is not reflected.Pressure selectionFunctionZone stateESP standard value01 V-H Variable High02 F-H Fixed High03 V-L Variable Low04 F-L Fixed LowOwnerʼs & Installation Manual 17

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!