Engineering<br />

Dimensions & Data<br />

Models<br />

<strong>ICT</strong> 3-63 to 4-912<br />

WEIGHTS (LBS) DIMENSIONS CONNECTIONS<br />

Fan Air<br />

MODEL Heaviest Motor Flow Water Water Make Over-<br />

NO. Shipping Operating Section (HP) (CFM) H B T L In Out Up Drain Flow<br />

<strong>ICT</strong> 3-63 520 880 520* 1 4,900 6' 2" 2' 1/2" 4' 1 1/2" 3' 3" 3" 1" 2" 2"<br />

3-73 560 920 560* 1 4,800 7' 2" 2' 1/2" 5' 1 1/2" 3' 3" 3" 1" 2" 2"<br />

3-83 650 970 390 1 4,700 8' 2" 2' 1/2" 6' 1 1/2" 3' 3" 3" 1" 2" 2"<br />

3-93 670 990 410 1 1/2 5,400 8' 2" 2' 1/2" 6' 1 1/2" 3' 3" 3" 1" 2" 2"<br />

<strong>ICT</strong> 4-54 710 1,510 710* 2 9,200 7' 7" 4' 3 1/4" 3' 3 3/4" 3' 11 7/8" 4" 4" 1" 2" 2"<br />

4-64 820 1,570 500 2 9,100 8' 7" 5' 3 1/4" 3' 3 3/4" 3' 11 7/8" 4" 4" 1" 2" 2"<br />

4-74 840 1,590 530 2 9,000 8' 7" 5' 3 1/4" 3' 3 3/4" 3' 11 7/8" 4" 4" 1" 2" 2"<br />

4-84<br />

4-94<br />

920<br />

970<br />

1,670<br />

1,720<br />

600<br />

600<br />

2<br />

3<br />

8,900<br />

10,100<br />

9' 7"<br />

9' 7"<br />

6' 3 1/4"<br />

6' 3 1/4"<br />

3' 3 3/4"<br />

3' 3 3/4"<br />

3' 11 7/8"<br />

3' 11 7/8"<br />

4"<br />

4"<br />

4"<br />

4"<br />

1"<br />

1"<br />

2"<br />

2"<br />

2"<br />

2"<br />

<strong>ICT</strong> 4-66 1,270 2,390 770 3 13,400 8' 7" 5' 3 1/4" 3' 3 3/4" 5' 11 7/8" 4" 4" 1" 2" 2"<br />

4-76 1,380 2,500 880 3 13,200 9' 7" 6' 3 1/4" 3' 3 3/4" 5' 11 7/8" 4" 4" 1" 2" 2"<br />

4-86<br />

4-96<br />

1,310<br />

1,420<br />

2,430<br />

2,550<br />

770<br />

880<br />

5<br />

5<br />

15,800<br />

15,500<br />

8' 7"<br />

9' 7"<br />

5' 3 1/4"<br />

6' 3 1/4"<br />

3' 3 3/4"<br />

3' 3 3/4"<br />

5' 11 7/8"<br />

5' 11 7/8"<br />

4"<br />

4"<br />

4"<br />

4"<br />

1"<br />

1"<br />

2"<br />

2"<br />

2"<br />

2"<br />

<strong>ICT</strong> 4-59 1,880 3,510 1,090 (2)2 19,700 8' 7" 5' 3 1/4" 3' 3 3/4" 8' 11 1/2" 4" 4" 1" 2" 2"<br />

4-69 1,990 3,620 1,200 (2)2 19,600 9' 7" 6' 3 1/4" 3' 3 3/4" 8' 11 1/2" 4" 4" 1" 2" 2"<br />

4-79 1,930 3,560 1,090 (2)3 22,300 8' 7" 5' 3 1/4" 3' 3 3/4" 8' 11 1/2" 4" 4" 1" 2" 2"<br />

4-89 2,040 3,670 1,200 (2)3 22,100 9' 7" 6' 3 1/4" 3' 3 3/4" 8' 11 1/2" 4" 4" 1" 2" 2"<br />

4-99 2,090 3,720 1,250 (2)3 21,900 9' 7" 6' 3 1/4" 3' 3 3/4" 8' 11 1/2" 4" 4" 1" 2" 2"<br />

<strong>ICT</strong>4-612 2,490 4,630 1,470 (2)3 27,000 8' 7" 5' 3 1/4" 3' 3 3/4" 11' 11 3/4" 6" 6" 1" 2" 2"<br />

4-712 2,590 4,730 1,570 (2)3 26,600 9' 7" 6' 3 1/4" 3' 3 3/4" 11' 11 3/4" 6" 6" 1" 2" 2"<br />

4-812 2,640 4,780 1,550 (2)5 31,600 9' 7" 6' 3 1/4" 3' 3 3/4" 11' 11 3/4" 6" 6" 1" 2" 2"<br />

4-912 2,770 4,910 1,670 (2)5 31,300 9' 7" 6' 3 1/4" 3' 3 3/4" 11' 11 3/4" 6" 6" 1" 2" 2"<br />

NOTE: (1) An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.<br />

(2) Overall unit height and connection locations may change slightly on units with FRP construction – See EVAPCO certified prints for exact dimensions.<br />

(3) Do not use catalog drawings for certified prints, dimensions subject to change.<br />