12.07.2015 Views

Mass flow meters - OPTIMASS 1000 - Forbes Marshall

Mass flow meters - OPTIMASS 1000 - Forbes Marshall

Mass flow meters - OPTIMASS 1000 - Forbes Marshall

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

2 TECHNICAL DATA<strong>OPTIMASS</strong> <strong>1000</strong>2.1 Technical data• The following data is provided for general applications. If you require data that is morerelevant to your specific application, please contact us or your local representative.• Additional information (certificates, special tools, software,...) and complete productdocumentation can be downloaded free of charge from the website (Download Center).Measuring systemMeasuring principleApplication rangeMeasured valuesCalculated valuesCoriolis mass <strong>flow</strong><strong>Mass</strong> <strong>flow</strong> and density measurement of fluids, gases and solids<strong>Mass</strong>, density, temperatureVolume, referred density, concentration, velocityDesignBasicFeaturesVariantsCompact versionRemote versionModbus versionSystem consists of a measuring sensor and a converter to process theoutput signalFully welded maintenance free sensor with twin straight measuring tubesIntegral converterAvailable with field, wall or 19" rack mount versions of the converterSensor with integral electronics providing Modbus output for connection to aPLCMeasuring accuracy<strong>Mass</strong>Liquid±0.15% of actual measured <strong>flow</strong> rate + zero stabilityGas±0.5% of actual measured <strong>flow</strong> rate + zero stabilityRepeatabilityBetter than 0.05% plus zero stability (includes the combined effects ofrepeatability, linearity and hysteresis)Zero stabilityStainless Steel±0.01% of maximum <strong>flow</strong> rate with respective sensor sizeReference conditionsProductWaterTemperature 20°C / 68°FOperating pressure1 barg / 14.5 psigEffect on sensor zero point caused by a shift in process temperatureStainless Steel 0.001% per 1°C / 0.00055% per 1°FEffect on sensor zero point caused by a shift in process pressureStainless Steel0.00012% of the max <strong>flow</strong> rate per 1 bar rel . / 0.0000083% of the max <strong>flow</strong> rateper 1 psigDensityMeasuring range 400...2500 kg/m 3 / 25...155 lbs/ft 3Accuracy ±2 kg/m 3 / ±0.13 lbs/ft 3 (S15: ±5 kg/m 3 / ±0.33 lbs/ft 3 )On site calibration ±0.5 kg/m 3 / ±0.033 lbs/ft 38www.krohne.com03/2011 - 4000040304 - TD <strong>OPTIMASS</strong> <strong>1000</strong> R05 en

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!