12.07.2015 Views

Y-TG, R-410A ZJ/ZR/ZF Series 15-25 ton, 60 Hertz - Usair-eng.com

Y-TG, R-410A ZJ/ZR/ZF Series 15-25 ton, 60 Hertz - Usair-eng.com

Y-TG, R-410A ZJ/ZR/ZF Series 15-25 ton, 60 Hertz - Usair-eng.com

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>25</strong>1934-Y<strong>TG</strong>-I-1008<strong>ZF</strong>180-300 Side Duct Application<strong>ZF</strong>180 (<strong>15</strong> Ton) Side DuctAir Flow(CFM)Available External Static Pressure - IWG 10.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHPStandard 5 HP & FieldStandard 5 HP & DriveHigh Static 5 HP & DriveSupplied Drive4400 7<strong>60</strong> 1.56 798 1.90 835 2.20 878 2.47 950 2.81 1014 3.11 1069 3.38 11<strong>15</strong> 3.61 1<strong>15</strong>4 3.81 1184 3.97 1205 4.09 1218 4.184800 786 1.93 824 2.27 861 2.57 904 2.84 976 3.18 1040 3.48 1095 3.75 1142 3.98 1180 4.18 1210 4.34 1231 4.46 1244 4.555200 8<strong>15</strong> 2.34 853 2.68 890 2.98 933 3.<strong>25</strong> 1005 3.59 1068 3.89 1123 4.16 1170 4.39 1208 4.59 1238 4.75 12<strong>60</strong> 4.87 1273 4.965<strong>60</strong>0 845 2.79 883 3.13 920 3.43 963 3.70 1035 4.04 1099 4.34 1<strong>15</strong>4 4.61 1200 4.84 1239 5.04 1269 5.20 1290 5.32 1303 5.41<strong>60</strong>00 877 3.28 9<strong>15</strong> 3.62 952 3.92 995 4.19 1067 4.53 1131 4.83 1186 5.10 1232 5.33 1271 5.53 1301 - - - - -6400 911 3.81 949 4.<strong>15</strong> 986 4.45 1029 4.72 1101 5.06 1164 5.36 1219 5.63 - - - - - - - - - -6800 946 4.38 984 4.72 1021 5.02 1064 5.29 - - - - - - - - - - - - - - - -7200 982 4.98 1020 5.32 1057 5.62 - - - - - - - - - - - - - - - - - -5 HP & Field Supplied Drive1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.3. kW = BHP x 0.838.<strong>ZF</strong>210 (17.5 Ton) Side DuctAvailable External Static Pressure - IWG 1Air Flow0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6(CFM)RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHPStandard 5 HP & Field Supplied Drive Standard 5 HP & Drive High Static 7.5 HP & Drive4400 636 0.65 672 1.14 709 1.<strong>60</strong> 745 2.03 780 2.43 8<strong>15</strong> 2.78 849 3.09 882 3.35 914 3.55 944 3.70 973 3.78 999 3.794800 649 0.99 685 1.48 721 1.94 757 2.37 793 2.77 828 3.12 862 3.43 895 3.69 927 3.89 957 4.04 985 4.12 1012 4.135200 663 1.34 700 1.83 736 2.29 772 2.72 808 3.11 843 3.47 877 3.78 910 4.04 942 4.24 972 4.39 1000 4.47 1027 4.485<strong>60</strong>0 680 1.71 717 2.20 753 2.66 789 3.09 8<strong>25</strong> 3.48 8<strong>60</strong> 3.84 894 4.<strong>15</strong> 927 4.41 959 4.61 989 4.76 1017 4.84 1044 4.85<strong>60</strong>00 699 2.11 735 2.<strong>60</strong> 772 3.06 808 3.49 844 3.88 879 4.24 913 4.55 946 4.80 977 5.01 1007 5.<strong>15</strong> 1036 5.24 1062 5.<strong>25</strong>6400 719 2.55 756 3.03 792 3.49 828 3.92 864 4.32 899 4.67 933 4.98 966 5.24 998 5.45 1028 5.59 1056 5.67 1083 5.686800 742 3.02 778 3.51 814 3.97 850 4.40 886 4.79 921 5.<strong>15</strong> 955 5.46 988 5.72 1020 5.92 1050 6.07 1078 6.<strong>15</strong> 1105 6.167200 765 3.54 802 4.03 838 4.49 874 4.92 910 5.32 945 5.67 979 5.98 1012 6.24 1044 6.44 1074 6.59 1102 6.67 1129 6.687<strong>60</strong>0 790 4.11 827 4.<strong>60</strong> 863 5.06 899 5.49 935 5.88 970 6.24 1004 6.55 1037 6.81 1069 7.01 1099 7.16 1127 7.24 1<strong>15</strong>4 7.<strong>25</strong>8000 817 4.72 853 5.21 890 5.67 926 6.10 962 6.50 997 6.85 1031 7.16 1064 7.42 1095 7.62 11<strong>25</strong> 7.77 1<strong>15</strong>4 7.85 1180 7.868400 845 5.38 881 5.87 918 6.33 954 6.76 990 7.16 10<strong>25</strong> 7.51 1059 7.82 1092 8.08 1123 8.28 1<strong>15</strong>3 8.43 1182 8.51 1208 8.528800 874 6.09 911 6.58 947 7.04 983 7.47 1019 7.86 1054 8.22 1088 8.53 - - - - - - - - - -High Static 7.5 HP &Field Supplied Drive1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.3. kW = BHP x 0.838.Johnson Controls Unitary Products 59

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!