Type 526Orifice TPressure temperature ratingsMetric UnitsTValve size 8 T 10 8 T 10 8 T 10Flange rating class Inlet x Outlet 150 x 150 300L x 150 300 x 150Actual Orifice diameter d 0 [mm] 161,5 161,5 161,5Actual Orifice area A 0 [mm 2 ] 20485 20485 20485Body material: WCB 1.0619Temperature rangePressure range p [bar] S/G/LMaximum -29 to 38 °C 4,5 20,7set pressure39 to 232 °C 4,5 20,7233 to 427 °C 4,5Use 8 T 1020,7Outlet pressure limit300 x 1502,1 6,9Conventional designOutlet pressure limitBalanced bellows designBody material: CF8M 1.4408Temperature range2,1 6,9Pressure range p [bar] S/G/LMaximum -268 to -60 °C 3,4 4,5set pressure-59 to -29 °C 4,5 8,3Outlet pressure limitConventional designOutlet pressure limitBalanced bellows designBody material: WC6 1.7357-28 to 38 °C 4,5 8,339 to 232 °C 4,5 Use 8 T 108,3233 to 427 °C 4,5 300 x 1508,3428 to 538 °C 1,4 8,3Temperature range2,1 4,12,1 4,1Pressure range p [bar] S/G/LMaximum 233 to 427 °C – 20,7set pressure428 to 538 °C – 15,5Outlet pressure limitConventional designOutlet pressure limitBalanced bellows designBody material: LCBTemperature rangeUse 8 T 10– 300 x 1506,9– 6,9Pressure range p [bar] S/G/LMaximum -46 to 38 °C 18,4 48,0set pressure39 to 200 °C 13,8 42,5201 to 343 °C 8,4 36,4Use 8 T 10Outlet pressure limit300 x 1502,1 6,9Conventional designOutlet pressure limitBalanced bellows design2,1 6,9Remark: SA 352 Gr. LCB is not listed in the <strong>API</strong> 526. Pressure-Temperature Rating acc. to ASME B16.34 Table 2-1.3The stated Pressure-Temperature Rating are taken from ASME B16.34 Table 2-1.3Due to the extended material test certificate the LESER LCB can be applied as LCC, WCB, WCC and 1.0619with the respective pressure-temperature range as well.01/70 LWN 480.01-E
Type 526Orifice TPressure temperature ratingsUS UnitsValve size 8 T 10 8 T 10 8 T 10Flange rating class Inlet x Outlet 150 x 150 300L x 150 300 x 150Actual Orifice diameter d 0 [inch] 6,36 6,36 6,36Actual Orifice area A 0 [inch 2 ] 31,75 31,75 31,75Body material: WCB 1.0619Temperature range Pressure range p [psig] S/G/LMaximum -20 to 100 °F 65 300set pressure101 to 450 °F 65 300451 to 800 °F 65Use 8 T 10300Outlet pressure limit300 x 15030 100Conventional designOutlet pressure limitBalanced bellows designBody material: CF8M 1.4408Temperature range30 100Pressure range p [psig] S/G/LMaximum -450 to -76 °F 50 65set pressure-75 to -21 °F 65 120-20 to 100 °F 65 120101 to 450 °F 65 Use 8 T 10120451 to 800 °F 65 300 x 150120801 to 1000 °F 20 120Outlet pressure limitConventional design30 60Outlet pressure limitBalanced bellows design30 60Body material: WC6 1.7357Temperature rangePressure range p [psig] S/G/LMaximum 451 to 800 °F – 300set pressure801 to 1000 °F – 225Outlet pressure limitUse 8 T 10–Conventional design300 x 150100Outlet pressure limitBalanced bellows design– 100Body material: LCBTemperature rangePressure range p [psig] S/G/LMaximum -50 to 100 °F 265 695set pressure101 to 400 °F 200 615401 to 650 °F 125Use 8 T 10535Outlet pressure limit300 x 15030Conventional design100Outlet pressure limitBalanced bellows design30 100TRemark: SA 352 Gr. LCB is not listed in the <strong>API</strong> 526. Pressure-Temperature Rating acc. to ASME B16.34 Table 2-1.3The stated Pressure-Temperature Rating are taken from ASME B16.34 Table 2-1.3Due to the extended material test certificate the LESER LCB can be applied as LCC, WCB, WCC and 1.0619with the respective pressure-temperature range as well.LWN 480.01-E01/71
- Page 1 and 2:
APIFlanged Safety Relief ValvesSeri
- Page 3 and 4:
ContentsChapter/PageGeneral 00/01Ap
- Page 5 and 6:
General InformationGeneralApplicati
- Page 7 and 8:
Valve finderHow to find the right A
- Page 9 and 10:
How to useSelection chartsGeneralTh
- Page 11 and 12:
How to useGeneral8Base of calculati
- Page 13 and 14:
LEOLGeneralThis table is based on t
- Page 15 and 16:
TypeType 526Type 526Packed lever H4
- Page 17 and 18:
Type 526Conventional designItemMate
- Page 19 and 20:
Type 526Balanced bellows designMate
- Page 21 and 22:
Type 5264 5 6Options Documentation
- Page 23 and 24:
Type 526Article numbers - OverviewA
- Page 25 and 26:
d 0 = Actual orifice diameterA 0 =
- Page 27 and 28:
d 0 = Actual orifice diameterA 0 =
- Page 29 and 30:
Type 526WeightsUS UnitsBonnetallLif
- Page 31 and 32:
Type 526Orifice DArticle numbers, d
- Page 33 and 34: Type 526Orifice DPressure temperatu
- Page 35 and 36: Type 526Orifice EArticle numbers, d
- Page 37 and 38: Type 526Orifice EPressure temperatu
- Page 39 and 40: Type 526Orifice FArticle numbers, d
- Page 41 and 42: Type 526Orifice FPressure temperatu
- Page 43 and 44: Type 526Orifice GArticle numbers, d
- Page 45 and 46: Type 526Orifice GPressure temperatu
- Page 47 and 48: Type 526Orifice HArticle numbers, d
- Page 49 and 50: Type 526Orifice HPressure temperatu
- Page 51 and 52: Type 526Orifice JArticle numbers, d
- Page 53 and 54: Type 526Orifice JPressure temperatu
- Page 55 and 56: Type 526Orifice KArticle numbers, d
- Page 57 and 58: Type 526Orifice KPressure temperatu
- Page 59 and 60: Type 526Orifice LArticle numbers, d
- Page 61 and 62: Type 526Orifice LPressure temperatu
- Page 63 and 64: Type 526Orifice MArticle numbers, d
- Page 65 and 66: Type 526Orifice MPressure temperatu
- Page 67 and 68: Type 526Orifice NArticle numbers, d
- Page 69 and 70: Type 526Orifice NPressure temperatu
- Page 71 and 72: Type 526Orifice PArticle numbers, d
- Page 73 and 74: Type 526Orifice PPressure temperatu
- Page 75 and 76: Type 526Orifice QArticle numbers, d
- Page 77 and 78: Type 526Orifice QPressure temperatu
- Page 79 and 80: Type 526Orifice RArticle numbers, d
- Page 81 and 82: Type 526Orifice RPressure temperatu
- Page 83: Type 526Orifice TArticle numbers, d
- Page 87 and 88: Type 526Flange facingsIndication St
- Page 89 and 90: Orifice900 x 300 1500 x 300 2500 x
- Page 91 and 92: Type 526Spare parts - Disc (Item 7)
- Page 93 and 94: Type 526Spare parts - Stainless ste
- Page 95 and 96: Type 526Spare parts - Gasket Body /
- Page 97 and 98: Type 526Spare parts recommendations
- Page 99 and 100: Type 526ApprovalsApprovalsOrifice D
- Page 101 and 102: Type 526Capacities - SteamCapacitie
- Page 103 and 104: Type 526Capacities - AirCapacities
- Page 105 and 106: Type 526Capacities - WaterCapacitie
- Page 107 and 108: Accessoriesand OptionsContentsChapt
- Page 109 and 110: Accessories and OptionsCaps and lev
- Page 111 and 112: Accessories and OptionsCaps and lev
- Page 113 and 114: Accessories and OptionsMetal seat -
- Page 115 and 116: Accessories and OptionsSoft seal di
- Page 117 and 118: Accessories and OptionsSoft sealSof
- Page 119 and 120: Accessories and OptionsBalanced bel
- Page 121 and 122: Accessories and OptionsLift indicat
- Page 123 and 124: Accessories and OptionsHeating jack
- Page 125 and 126: Accessories and OptionsO-ring dampe
- Page 127 and 128: Fax OrderPlease send your request t