7.163 Humidity Sensor StepFigure 36 shows the voltage input setup for the humidity sensor <strong><strong>an</strong>d</strong> NI USB-6008 device.Figure 36: Labview Signal Express Voltage Input Setup<strong>The</strong> same timing settings were selected as for the thermocouple setup.When the two steps had been set up a test run was undertaken to confirm accurate readingswere being taken.<strong>The</strong> data acquisition system was now setup up <strong><strong>an</strong>d</strong> data was ready to be recorded.Niall Carroll Page 56<strong>The</strong> <strong>The</strong>rmal <strong><strong>an</strong>d</strong> <strong>Rainwater</strong> <strong>Run<strong>of</strong>f</strong> <strong>Perform<strong>an</strong>ce</strong> <strong>of</strong> <strong>an</strong> <strong>Extensive</strong> Green Ro<strong>of</strong> System