ISOLATED HEART PERFUSION SYSTEMThe IH-SR Basic Consists of theCore System & Core OptionsLangendorff only ConfigurationBasic IH-SR Core System (choose one)• 73-4344 (115V)• 73-4343 (230V)Species Specific Addition (choose one or both)• 73-4019 IHSR-MOUSE• 73-4020 IHSR-RGPSCP (Servo Pressure Controller)• 73-2806Langendorff Working <strong>Heart</strong>-ReadyConfiguration 11Upgrade from Langendorff <strong>to</strong> Working <strong>Heart</strong> is facilitated by purchasing this configuration2If you work with both mouse and rat models, choose the IHSR-FLOW-RGP• Basic IH-SR Core System (choose one)• 73-4344 (115V)• 73-4343 (230V)Species Specific Addition (choose one or both)• 73-4019 IHSR-MOUSE• 73-4020 IHSR-RGPSTARLING-IHSR (Pressure Controller)• 73-4346Direct Flow Measurement (choose one, see page 20) 2• 73-4021 IHSR-FLOW-M• 73-4022 IHSR-FLOW-RGPIH-SR Core System, Basic: 73-4344(115V) OR 73-4343 (230V)Includes:• IH-SR Base Unit for Small Rodent <strong>Heart</strong>s(for subjects up <strong>to</strong> 800 g)• Thermocircula<strong>to</strong>r• Analog Roller Pump• PLUGSYS Basic System Case 603° Core System Utilizes 4 of 20 <strong>to</strong>tal Slot Units• <strong>Perfusion</strong> Pressure Measurements° Pressure Transducer° TAM-D PLUGSYS Transducer Amplifier Module• Left Ventricular Pressure Measurement° Pressure Transducer° Holder for Pressure Transducer° TAM-A PLUGSYS Transducer Amplifier Module* If your chosen options require more than 20 Slot Unitsyou will need <strong>to</strong> choose the case expansion option(Option C-EX). See page 59.For a working unit, the core system requires the additionof a selection of one of the perfusion pressurecontroller systems (SCP or STARLING-IHSR) and oneof the options IHSR-MOUSE or IHSR-RAT/GP. Theworking heart ready configuration also requires thespecies-appropriate direct flow measurement option.IHSR-MOUSE 73-4019Additions <strong>to</strong> IH-SR Core System for mouse heartsIncludes:• Aortic Cannula for Mouse <strong>Heart</strong>s, 1.0 mm OD• Pump Tubing (TYGON)• Mini Balloon Kit for Mouse <strong>Heart</strong>• Mouse Ventricular Balloon Assembly Kit• 1 Liter Jacketed Buffer Reservoir and tube setIHSR-RAT/GP 73-4020Additions <strong>to</strong> IH-SR Core System forrat/guinea pig heartsIncludes:• Aortic Cannula for rat & guinea pig hearts° 2.3 mm OD° 3.0 mm OD• Pump Tubing (TYGON)• 2 Liter Jacketed Buffer Reservoir and Tube Set• Balloon Kit for rat/guinea pig hearts° Stainless Steel LVP Balloon Catheter° 10 Size 5 Balloons (0.1 ml volume)° Spindle Syringe & Holder for Precise Adjustment ofPreload Pressure18 email physiology@harvardapparatus.com web www.hugo-sachs.de • www.harvardapparatus.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!