12.07.2015 Views

2010 NRMCA - National Ready Mixed Concrete Association

2010 NRMCA - National Ready Mixed Concrete Association

2010 NRMCA - National Ready Mixed Concrete Association

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

References1Obla, K.H., “How Good is your QC – Part I of <strong>Concrete</strong> Quality Series,” <strong>Concrete</strong> InFocus, May-June <strong>2010</strong>, Vol. 9, No. 3, <strong>NRMCA</strong>, pp.17-18.2Obla, K.H., “Sources of <strong>Concrete</strong> Strength Variation – Part II of <strong>Concrete</strong> Quality Series,” <strong>Concrete</strong> InFocus, July-August <strong>2010</strong>, Vol. 9, No. 4,<strong>NRMCA</strong>, pp. 21-23.3ASTM C94, “Standard Specification for <strong>Ready</strong> <strong>Mixed</strong> <strong>Concrete</strong>,” Volume 4.02, ASTM International, West Conshohocken, PA, 2009, www.astm.org.4ACI Committee 117, “Specifications for Tolerances for <strong>Concrete</strong> Construction and Materials and Commentary,” American <strong>Concrete</strong> Institute,Farmington Hills, MI, 2006, 70 pp.5ACI Committee 214, “Evaluation of Strength Test Results of <strong>Concrete</strong> (ACI 214R-02),” American <strong>Concrete</strong> Institute, Farmington Hills, MI,2005, 20 pp.Table 1. Statistical Summary of Project Slump Test Results Sent by 5 Different <strong>Concrete</strong> ProducersProducer ID # of measurements Average Slump, in. Slump Range, in. Percent in compliance with C94 tolerance of ±1.5 in.A 305 5.2 1.75 – 6.75 98.0B 57 6.9 5.00-8.00 94.7C 41 7.6 3.50-10.50 73.2D1 304 4.8 2.00-8.00 97.4D2 62 8.4 6.25-9.50 95.2Table 2. Statistical Summary of Project Air Content Test Results Sent by 5 Different <strong>Concrete</strong> ProducersProducer ID # of measurements Average Air Content, % Air Content Range, in. Percent in compliance with C94 toleranceof ±1.5%A 302 5.6 3.4-6.9 99.7B 57 5.4 3.9-7.1 96.5C 41 2.9 2.2-4.0 90.2*D1 302 2.0 1.0-4.5 92.1*D2 17 1.0 0.8-1.4 100**Non air entrained concrete does not have C94 air content tolerances. So ±0.75% was assumedTable 3. Statistical Summary of Project Test Results Sent by 5 Different <strong>Concrete</strong> ProducersProducer ID Slump, in. Air Content, % Temperat., o F SD of SD of 7 d 28 day StrengthDensity, Strength,AVG SD AVG SD AVG SD lb/ft3 psi AVG, psi SD, psi Standard ofControl*PredictedSD, psi**A 5.2 0.67 5.6 0.46 68.3 6.3 NA 485 5578 438 Very Good 307B 6.9 0.73 5.4 0.81 68.5 6.8 1.36 624 4952 536 Good 362C 7.6 1.69 2.9 0.46 63.0 10.8 1.26 1701 9450 1258 Fair 890D1 4.8 0.59 2.0 0.45 72.0 6.4 1.51 594 5213 474 Very Good 281D2 8.4 0.76 1.0 0.18 78.0 5.7 0.52 1167 6632 938 Poor 294*Standard of Control per ACI 214**Predicted SD based on slump and air content compliance probabilitiesCONCRETE in focus ı 31

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!