12.07.2015 Views

Time Interval and Frequency Counter

Time Interval and Frequency Counter

Time Interval and Frequency Counter

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

32 Programming Comm<strong>and</strong>ssynchronizing of the measurements with thereturned answers.DREL (?) jThe DREL comm<strong>and</strong> sets the display rel <strong>and</strong> isequivalent to the front panel "SET REL" button.The parameter j = 1 sets the REL, j = 0 clears theREL, <strong>and</strong> j = 2 clears the REL <strong>and</strong> the results ofthe last measurement, j =3 sets the REL to thecurrent cursor position.COMPThe COMP comm<strong>and</strong> changes the arming parityin ± time arming mode. This comm<strong>and</strong> is the sameas toggling the state of the front panel COMPLLED.GATE (?) xThe GATE comm<strong>and</strong> sets the width of thefrequency, period, or count gate to x. The gatewidth x may range from 1ms to 500s in a 1,2,5sequence. If the value x is negative the gate is setto an externally triggered gate of width x. If themeasurement mode or arming mode do notsupport gates an error occurs.JTTR (?) jThe JTTR comm<strong>and</strong> sets the type of jittercalculation. The parameter j = 0 sets st<strong>and</strong>arddeviation calculation while j = 1 sets Allanvariance. It should be noted that the jitter type is aproperty of the present mode <strong>and</strong> that if the modeis changed the jitter type may also change.MODE (?) jThe MODE comm<strong>and</strong> sets the instrumentmeasurement mode according to the followingtable:jmode0 time1 width2 rise/fall time3 frequency4 period5 phase6 countNote: after setting the SR620's mode the othermeasurement parameters should be set to theirdesired values because changing modes maycause them to change.SIZE (?) xThe SIZE comm<strong>and</strong> sets the number of samplesin a measurement. The parameter x may bebetween 1 <strong>and</strong> 10^6 in a 1,2,5 sequence. TheSIZE? query returns a floating point number withone significant digit.SRCE (?) jThe SRCE comm<strong>and</strong> sets the source of themeasurement. The parameter j = 0 set the sourceto A, j = 1 sets the source to B, <strong>and</strong> j = 2 sets thesource to REF. Additionally, in frequency, period,<strong>and</strong> count modes j = 3 sets the source to ratio(A/B). In phase mode the source is fixed <strong>and</strong> maynot be set while in rise/fall time REF may not beselected as the source.STRTThe STRT comm<strong>and</strong> is equivalent to pushing thefront panel START button.STOPThe STOP comm<strong>and</strong> resets the presentmeasurement <strong>and</strong> is the same as pressing the"RESET" button on the front panel.Data Transmission Comm<strong>and</strong>sMEAS? jThe MEAS? query starts a measurement <strong>and</strong>returns the result when the measurement iscomplete. The parameter j selects which statisticis to be returned.jstatistic0 mean1 jitter2 max3 minThis comm<strong>and</strong> always returns the value of thenext complete measurement. Thus, if ameasurement is in progress the comm<strong>and</strong> willreturn the value of the present measurement whenit is done, not a new measurement. It isrecommended that automeasure be off whenusing this comm<strong>and</strong> to ensure that the resultSR620 Universal <strong>Time</strong> <strong>Interval</strong> <strong>Counter</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!