12.07.2015 Views

Hitachi Inverter Rope Hoist

Hitachi Inverter Rope Hoist

Hitachi Inverter Rope Hoist

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Super V Series and V8 Series6Super V SeriesV8 Series<strong>Hoist</strong>ingTraversing<strong>Hoist</strong>ing lift<strong>Inverter</strong>-basedcontrol of hoistingTraversingWire rope<strong>Hoist</strong>ing liftWire rope<strong>Inverter</strong>basedCommercialMotorMotorCapacity t 15<strong>Hoist</strong> load t 15.2Standard Low hoisting lift8mHeadroom Type High hoisting lift12Double-Rail TypeLow hoisting lift 8mHigh hoisting lift12m/s0.01−0.100.15Speed 2m/min0.6− 6.0 9.0Output kW162 The figures in [ ] are the no-load operation speeds.Capacity t 1/2 1 2 2.8 3 5 7.5 10<strong>Hoist</strong> load t 0.51 1.01 2.02 2.83 3.03 5.07 7.65 10.2Standard Headroom TypeLow hoisting lift66 6 6 6 8 8 8mHigh hoisting lift1212 12 12 12 12 12 12Low Headroom TypeLow hoisting lift 6 6 6 6 6 6 − −mHigh hoisting lift − 12 12 12 12 11 − −Double-Rail TypeLow hoisting lift − − − 6 6 8 8 8mHigh hoisting lift− − 12 12 12 12 12 12m/s0.022− 0.217 0.3250.022−0.217 0.325 0.017−0.167 0.25 0.015− 0.15 0.225 0.015−0.15 0.225 0.013−0.133 0.2 0.012−0.12 0.18 0.01−0.100.15Speed 1m/min1.3− 13 19.51.3−13 19.5 1.0−10 15 0.9− 9.0 13.5 0.9− 9.0 13.5 0.8−8.0 12 0.72−7.2 10.8 0.6−6.0 9.0Motor outputkW1.2 2.3 3.5 4.8 5.0 7.0 9.5 10.5No. of poles of the motor 4 4 4 4 4 4 4 4Speedm/s0.042− 0.417 0.042−0.417 0.042−0.417 0.042−0.417 0.042−0.417 0.042−0.417 0.028− 0.283 0.028−0.283m/min 2.5−25 2.5−25 2.5−25 2.5− 25 2.5−25 2.5−25 1.7−17 1.7− 17Standard Headroom TypeMotorLow Headroom TypeoutputDouble-Rail TypeSpeedStandardHeadroom TypeLowHeadroom TypeDouble-Rail TypeMotoroutputNo. of poles of the motorStandard Headroom TypeLow Headroom TypeDouble-Rail Type1 The figures in [ ] are the no-load operation speeds.Table of standard specificationsCommon to50 and 60Hz50Hz60Hz50Hz60Hz50Hz60Hz50Hz60HzTable of standard specificationskW0.36 0.36 0.36 0.55 0.55 0.75 0.56×2 0.56×20.36 0.36 0.36 0.55 0.55 0.75 − −− − 0.36 0.55 0.55 0.55 0.55×2 0.55×2m/s 0.35 0.35 0.35 0.35 0.35 0.35 0.233 0.233m/min 21 21 21 21 21 21 14 14m/s 0.417 0.417 0.417 0.417 0.417 0.417 0.283 0.283m/min 25 25 25 25 25 25 17 17kW0.30 0.30 0.30 0.45 0.45 0.63 0.47×2 0.47×20.36 0.36 0.36 0.55 0.55 0.75 0.56×2 0.56×20.30 0.30 0.30 0.45 0.45 0.63 − −0.36 0.36 0.36 0.55 0.55 0.75 − −− − 0.30 0.45 0.45 0.45 0.45×2 0.45×2− − 0.36 0.55 0.55 0.55 0.55×2 0.55×2Standard Headroom Type 4 4 4 4 4 4 6 6Low Headroom Type4 4 4 4 4 4 − −Double-Rail Type − − 4 4 4 4 4 4No. of strands22 2 2 2 4 4 4Composition6×W (19)-B6×Fi (29)-B 6×Fi (29)-B 6×Fi (29)-B 6×Fi (29)-B 6×Fi (29)-B 6×Fi (29)-B 6×Fi (29)-BDiameter mm 6.3 8 11.2 14 14 12.5 14 16No. of strands44 4 4 4 4 − −Composition6×W (19)-B6×W (19)-B 6×Fi (29)-B 6×Fi (29)-B 6×Fi (29)-B 6×Fi (29)-B − −Diameter mm 4 6.3 8 10 10 12.5 − −No. of strands −− 4 4 4 4 4 4Composition −− 6×Fi (29)-B 6×Fi (29)-B 6×Fi (29)-B 6×Fi (29)-B 6×Fi (29)-B 6×Fi (29)-BDiameter mm − − 8 10 10 12.5 14 160.5− 5.0 7.50.33−3.3 5.01818No. of poles 4 4 4Speedm/s 0.028− 0.2830.028−0.2830.028−0.283m/min 1.7−171.7−171.7−17OutputkW 0.55×20.55×20.84×2No. of poles 4 4 4Number of strands44−Standard HeadroomTypeComposition6×Fi (29)-B6×Fi (29)-B −Diameter mm2022.4 −Number of strands448Double-Rail Type Composition6×Fi (29)-B6×Fi (29)-B6×Fi (29)-BDiameter mm2022.4202020.3−12−120.008− 0.083 0.1253030.4−−−120.006−0.055 0.083Standard specificationsOperation methodPower supplyProtection structureStandard productOperation voltageFrequency of starting<strong>Hoist</strong>ingRepetitive ratingDuty factor(rate of loading 0.63)Frequency of startingTraversingDuty factorPower supply methodThree-phase 200V 50/60Hz 380V 50Hz 440V 60Hz220V 60Hz400V 50/60HzPushbuttons on the pendant Eight pushbuttons designed to be operated by an operator standing on the floor (on, off, up, down, east, west, south and north)The pushbuttons with 2 depressed positions are as follows:<strong>Inverter</strong>-based control of hoisting and traversing : up, down, east, west, south and north<strong>Inverter</strong>-based control of hoisting only : up and down<strong>Inverter</strong>-based control of traversing only : east and west200VAC or 220VAC400 times per hour40%ED400 times per hour40%EDPower is supplied via cable. (In the case where a contact type current collector such as a collector/bus duct is used, please make sure that a double-trolley system is used.)JIS C0920 IP44In the case of outdoor use, please provide a covered refuge bay so that the hoist is not exposed to rain.The IP rating is for the motor section and the control panel.−10 to +40 ˚C (without freezing)90% or less (without condensation)Ambient temperatureHumidityPaint color Munsell 2.5B, 2.5/1Compliance with standardsJIS C9620 (Electric <strong>Hoist</strong>s), a crane structure standardSafety instructions for using the productStandard specification products cannot be used in special environments such as the ones listedbelow. Please contact us if you need a product that can be used in such environments.(1) Acid, alkali and saline atmospheres and corrosive gas atmospheres(2) Environments with an ambient temperature higher than 40 ˚C(3) Dusty environments(4) Environments in which the product is subjected to water splashes(5) Environments with a risk of ignited explosion such as environments in which volatile dust oran organic solvent exists(6) Environments in which the product is used very frequentlyFor the use of the product in a place with significant power supply noises, we recommend that anoise filter be installed, because such noises can cause malfunctioning such as a sudden stop.An inverter hoist will not stop immediately after the OFF pushbutton is pressed. The function to start and stop the hoistwith reduced impacts requires a deceleration distance that is proportional to the operating speed. Therefore, be sure tooperate the hoist taking into account the deceleration distance. In particular, please allow for a sufficient decelerationdistance when you operate the hoist at a high speed above the rated speed with the hoist carrying no load.If the hoist is operated continuously for more than 1 minute at the lowest speed, the inverter’ s overheatingprotection function may be activated to stop the hoist. In that event, please leave the hoist stopped until theinverter cools down (usually 5 minutes or more) before restarting the hoist.The inverter hoist requires a time period of about 4 seconds before it becomes capable of operating after theON pushbutton is pressed. Do not press any pushbutton during this period.7of standard6Tablespecifications

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!