SFO Template - Office of Construction & Facilities Management Home

SFO Template - Office of Construction & Facilities Management Home

SFO Template - Office of Construction & Facilities Management Home

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Department <strong>of</strong>Veterans Affairs<strong>Office</strong> <strong>of</strong> <strong>Construction</strong> & <strong>Facilities</strong> <strong>Management</strong>MAY 2009Lease BasedOutpatientClinictemplate <strong>SFO</strong>appendix B


SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]THIS PAGE INTENTIONALLY LEFT BLANK FOR REPRODUCTION PURPOSES.Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]DEPARTMENT OF VETERANS AFFAIRSOUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MINIMUM _________ NET USABLE SQUARE FEETNAME: ________________________TITLE: Contracting <strong>Office</strong>rNAME: ________________________TITLE: Project ManagerOffers are solicited under Section 40 U.S.C. 490(H)(1), AS AMENDED, AND Section 1 <strong>of</strong> theReorganization Plan <strong>of</strong> 1950 (40 U.S.C. 490 Note).The information collection requirements contained in this Solicitation/Contract that are notrequired by regulation, have been approved by the <strong>Office</strong> <strong>of</strong> <strong>Management</strong> and Budget pursuant tothe Paperwork Reduction Act and assigned the OMB Control No. 3090-0163.Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]3.5 TAX ADJUSTMENTS .............................................................................................................. 193.5.1 PURPOSE .................................................................................................................. 193.5.2 DEFINITIONS ............................................................................................................ 193.5.3 ADJUSTMENT FOR CHANGES IN REAL ESTATE TAXES .................................... 203.5.4 TAX APPEALS ........................................................................................................... 223.6 INSURANCE ADJUSTMENTS ................................................................................................ 223.7 OPERATING COSTS .............................................................................................................. 233.8 CONTRACT CHANGES .......................................................................................................... 243.8.1 APPLICABLE TO CHANGES COSTING OVER $500,000 ....................................... 243.8.2 APPLICABLE TO CHANGES COSTING $500,000 OR LESS .................................. 253.9 WAIVER OF CLAIMS FOR WASTE OR DAMAGES .............................................................. 273.10 LIQUIDATED DAMAGES ........................................................................................................ 273.11 RECORDATION REQUIREMENTS ........................................................................................ 273.12 ADJUSTMENT FOR VACATED PREMISES .......................................................................... 273.13 RELOCATION ASSISTANCE ACT ......................................................................................... 283.14 RENTABLE AND NET USABLE SQUARE FEET ................................................................... 283.14.1 RENTABLE SPACE ................................................................................................... 283.14.2 NET USABLE SPACE ................................................................................................ 283.15 APPURTENANT AREAS ......................................................................................................... 293.16 VENDING FACILITIES ............................................................................................................ 293.17 DESIGN AND CONSTRUCTION DOCUMENTS AFTER AWARD ......................................... 293.17.1 RESPONSIBILITIES OF LESSOR’S DESIGN TEAM ............................................... 293.17.2 INDEPENDENT TECHNICAL REVIEW ..................................................................... 303.18 DESIGN DEVELOPMENT ....................................................................................................... 313.19 CONSTRUCTION DOCUMENTS ............................................................................................ 313.20 SUBMITTAL REQUIREMENTS FOR DD AND CD REVIEWS ............................................... 323.20.1 GENERAL REQUIREMENTS .................................................................................... 323.20.2 FIRST DESIGN DEVELOPMENT SUBMITTAL ........................................................ 333.20.3 SECOND DESIGN DEVELOPMENT SUBMITTAL ................................................... 353.20.4 75% CONSTRUCTION DOCUMENTS ...................................................................... 393.20.5 100% CONSTRUCTION DOCUMENTS .................................................................... 423.20.6 APPROVED PLANS AND PERMITS ......................................................................... 423.21 PROJECT SCHEDULE ............................................................................................................ 423.21.1 NAS SCHEDULE ....................................................................................................... 423.21.2 SCHEDULE UPDATES .............................................................................................. 423.21.3 DATES ....................................................................................................................... 433.21.4 ACTIVITIES ................................................................................................................ 433.21.5 GOVERNMENT REVIEW .......................................................................................... 433.22 PROGRESS REPORTS .......................................................................................................... 443.22.1 REMEDIAL ACTION .................................................................................................. 443.22.2 REVISIONS TO SCHEDULE ..................................................................................... 443.22.3 APPROVAL OF SCHEDULE ..................................................................................... 453.22.4 COSTS OF REVISIONS ............................................................................................ 453.23 CONSTRUCTION OBSERVATION ......................................................................................... 453.23.1 RESIDENT ENGINEER’S OFFICE SPACE .............................................................. 453.24 SAMPLES AND SHOP DRAWINGS ....................................................................................... 483.25 CONSTRUCTION WASTE MANAGEMENT ........................................................................... 483.26 USE OF FACILITY PRIOR TO DATE OF POSSESSION ....................................................... 483.27 PLANS: AFTER OCCUPANCY ............................................................................................... 493.28 PARTNERING ......................................................................................................................... 493.29 VAAR-85273-75 SECURITY REQUIREMENTS FOR UNCLASSIFIED INFORMATIONTECHNOLOGY RESOURCES (INTERIM – OCTOBER 2008) ............................................... 49Table <strong>of</strong> Contents – iiiLessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]SECTION 4 GENERAL DESIGN CRITERIA .............................................................................. 514.1 CODES .................................................................................................................................... 514.2 CRITERIA FOR VA FACILITIES.............................................................................................. 514.2.1 VA ADOPTED CODES, STANDARDS, AND EXECUTIVE ORDERS ...................... 514.2.2 SPECIAL BUILDING REQUIREMENTS .................................................................... 544.2.3 EXCLUSIONS FROM NET USABLE SPACE ............................................................ 554.2.4 PHYSICAL SECURITY AND NATURAL DISASTERS RESISTIVE DESIGN ........... 564.3 FIRE PROTECTION ................................................................................................................ 674.3.1 SITE CONSIDERATIONS .......................................................................................... 674.3.2 BUILDING CONSTRUCTION .................................................................................... 674.3.3 OCCUPANCY TYPE .................................................................................................. 684.3.4 MEANS OF EGRESS ................................................................................................ 684.3.5 FIRE PROTECTION IN HAZARDOUS AND HIGH HAZARD AREAS ...................... 684.4 ENVIRONMENTAL .................................................................................................................. 694.4.1 INDOOR AIR QUALITY ............................................................................................. 694.4.2 ASBESTOS ................................................................................................................ 694.4.3 RADON MEASUREMENT AND CORRECTIVE ACTION ......................................... 704.4.4 RADON IN WATER .................................................................................................... 704.4.5 POTABLE WATER QUALITY .................................................................................... 714.5 SPECIAL ENVIRONMENTAL REQUIREMENTS .................................................................... 714.6 ACCESSIBILITY STANDARDS ............................................................................................... 714.7 OSHA REQUIREMENTS ......................................................................................................... 734.8 SUSTAINABLE DESIGN AND ENERGY EFFICIENCY .......................................................... 734.8.1 LEED® SILVER EQUIVALENCY ............................................................................... 734.8.2 STRATEGIES ............................................................................................................ 74SECTION 5 SITE DESIGN CRITERIA ....................................................................................... 785.1 GENERAL ................................................................................................................................ 785.2 SITE DEVELOPMENT ............................................................................................................. 785.2.1 STORM WATER ........................................................................................................ 795.2.2 CIRCULATION ........................................................................................................... 795.2.3 LOCATION OF BUILDING AND EQUIPMENT .......................................................... 795.2.4 PATIENT USE AREAS .............................................................................................. 795.2.5 GRADING DESIGN .................................................................................................... 795.2.6 DESIGN OF VEHICULAR AND PEDESTRIAN PAVEMENT .................................... 805.2.7 ENTRANCES TO BUILDING ..................................................................................... 815.2.8 TRUCK DOCK ........................................................................................................... 815.2.9 PARKING FACILITIES ............................................................................................... 815.2.10 EQUIPMENT PADS ................................................................................................... 825.3 LANDSCAPING DESIGN ........................................................................................................ 835.4 SITE AMENITIES ..................................................................................................................... 845.4.1 FLAGPOLE ................................................................................................................ 845.4.2 SMOKING SHELTERS .............................................................................................. 845.4.3 CANOPIES AND COVERED WALKWAYS ............................................................... 845.4.4 EXTERIOR ACTIVITY AREAS AND YARDS ............................................................ 855.5 UTILITIES ................................................................................................................................ 855.5.1 WATER DISTRIBUTION SYSTEM ............................................................................ 855.5.2 WATER SUPPLY FOR FIRE PROTECTION ............................................................ 855.5.3 //LAWN IRRIGATION SYSTEM ................................................................................. 865.5.4 SANITARY SEWERAGE SYSTEM ........................................................................... 865.5.5 STORM DRAINAGE SYSTEM................................................................................... 875.5.6 GAS DISTRIBUTION SYSTEM ................................................................................. 87Table <strong>of</strong> Contents – ivLessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]5.5.7 ELECTRICAL SERVICE ............................................................................................ 875.5.8 TELECOMMUNICATIONS SERVICES ..................................................................... 875.6 EXTERIOR SIGNAGE ............................................................................................................. 885.7 FENCING ................................................................................................................................. 88SECTION 6 BUILDING DESIGN CRITERIA .............................................................................. 906.1 STRUCTURAL ......................................................................................................................... 906.1.1 FOUNDATIONS ......................................................................................................... 906.1.2 FLOOR LOADS .......................................................................................................... 906.1.3 ROOF LOAD .............................................................................................................. 906.1.4 LATERAL FORCES ................................................................................................... 906.1.5 SPECIAL INSPECTIONS ........................................................................................... 916.1.6 BLAST LOADS ........................................................................................................... 916.2 ARCHITECTURAL ................................................................................................................... 916.2.1 FOUNDATION DRAINAGE ........................................................................................ 916.2.2 PATIENT ENTRANCES ............................................................................................. 916.2.3 AMBULANCE ENTRANCES ...................................................................................... 916.2.4 LOADING DOCKS ..................................................................................................... 926.2.5 //CANOPIES OR COVERED WALKS// ...................................................................... 926.2.6 ENCLOSURE SYSTEMS ........................................................................................... 926.3 EQUIPMENT ............................................................................................................................ 956.3.1 GENERAL .................................................................................................................. 956.3.2 LESSOR FURNISHED SPECIAL EQUIPMENT ........................................................ 966.3.3 //PROVISIONS FOR VA-FURNISHED/VA-INSTALLED EQUIPMENT// ................... 966.4 MECHANICAL ......................................................................................................................... 976.4.1 INTRODUCTION ........................................................................................................ 976.4.2 MANDATORY PROVISIONS ..................................................................................... 976.4.3 APPLICABLE CODES AND CRITERIA ..................................................................... 976.4.4 HVAC DESIGN CALCULATIONS .............................................................................. 976.4.5 HVAC SYSTEM SELECTION CRITERIA – AIR SIDE .............................................. 996.4.6 ALL-AIR SYSTEMS ................................................................................................... 996.4.7 FAN COIL UNITS ..................................................................................................... 1026.4.8 CLOSED-LOOP – GROUND SOURCE HEAT PUMPS (GSHP) ............................ 1036.4.9 REFRIGERATION SYSTEMS – CHILLED WATER AND DIRECT-EXPANSION(DX) SYSTEMS ........................................................................................................ 1046.4.10 CHILLED WATER SYSTEMS .................................................................................. 1046.4.11 DIRECT-EXPANSION (DX) SYSTEMS ................................................................... 1056.4.12 HEATING SYSTEMS ............................................................................................... 1056.4.13 PIPING SYSTEMS – BASIC REQUIREMENTS ...................................................... 1066.4.14 AIR DISTRIBUTION SYSTEM ................................................................................. 1086.4.15 INSULATION ............................................................................................................ 1096.4.16 APPLICATIONS ....................................................................................................... 1096.5 FIRE PROTECTION .............................................................................................................. 1126.5.1 FIRE EXTINGUISHERS ........................................................................................... 1126.5.2 FIXED FIRE EXTINGUISHING SYSTEMS .............................................................. 1126.5.3 AUTOMATIC SPRINKLER //AND STANDPIPE// SYSTEMS .................................. 1126.6 PLUMBING ............................................................................................................................ 1146.6.1 GENERAL ................................................................................................................ 1146.6.2 MANDATORY PROVISIONS ................................................................................... 1146.6.3 APPLICABLE CODES AND CRITERIA ................................................................... 1146.6.4 PLUMBING DESIGN SCOPE .................................................................................. 1146.6.5 PLUMBING FIXTURES, TRIM AND EQUIPMENT ................................................. 119Table <strong>of</strong> Contents – vLessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]7.5.3 SPECIAL X-RAY CONTROL ROOM REQUIREMENTS ......................................... 1567.6 INTERIOR FINISHES ............................................................................................................ 1567.6.1 GENERAL ................................................................................................................ 1567.6.2 INTERIOR DESIGN CRITERIA ............................................................................... 1577.7 CEILINGS .............................................................................................................................. 1577.7.1 ACOUSTICAL CEILINGS ........................................................................................ 1577.7.2 CUBICLE CURTAIN TRACKS ................................................................................. 1587.8 FLOORING ............................................................................................................................ 1587.8.1 MEMBRANE WATERPROOFING AT INTERIOR FLOOR DRAINS ....................... 1597.8.2 FLOOR SLAB DEPRESSIONS................................................................................ 1597.8.3 FLOORING, CERAMIC TILE ................................................................................... 1597.8.4 FLOORING, VINYL TILE AND SHEET VINYL ........................................................ 1607.8.5 FLOORING, RUBBER ............................................................................................. 1607.8.6 FLOORING, CARPET .............................................................................................. 1607.8.7 FLOORING, LATEX MASTIC .................................................................................. 1627.8.8 //COMPUTER ROOM FLOORING .......................................................................... 1627.9 WALL COVERINGS ............................................................................................................... 1647.9.1 CERAMIC WALL TILE ............................................................................................. 1647.9.2 MAINTENANCE AND REPLACEMENT .................................................................. 1657.10 PAINTING .............................................................................................................................. 1657.11 HANDRAILS, WALL GUARDS AND CORNER GUARDS .................................................... 1677.11.1 HANDRAILS AND WALL GUARDS ......................................................................... 1677.11.2 CORNER GUARDS ................................................................................................. 1687.12 INTERIOR SIGNAGE ............................................................................................................ 1697.13 BUILT-IN WORK .................................................................................................................... 1697.13.1 CASEWORK AND COUNTERTOPS ....................................................................... 1697.13.2 COMPUTER WORKSTATIONS AND KEYBOARD TRAYS ................................... 1727.13.3 LOCKERS AND SHELVING .................................................................................... 1727.14 PLUMBING FIXTURES, TOILETS AND BATHS ................................................................... 1727.14.1 TOILETS .................................................................................................................. 1727.14.2 SHOWERS ............................................................................................................... 1737.14.3 TOILET AND SHOWER ACCESSORIES ................................................................ 1737.15 WINDOW TREATMENTS ...................................................................................................... 1747.15.1 WINDOW BLINDS ................................................................................................... 1747.15.2 CLOTH WINDOW SHADES .................................................................................... 1747.16 //HOLDING ROOM ................................................................................................................ 174SECTION 8 SERVICES, UTILITIES AND MAINTENANCE ..................................................... 1768.1 UTILITIES .............................................................................................................................. 1768.2 BUILDING MAINTENANCE AND CLEANING BY LESSOR ................................................. 1768.2.1 BUILDING MAINTENANCE BY LESSOR ............................................................... 1768.2.2 EXTERIOR CLEANING BY LESSOR ...................................................................... 1788.2.3 //INTERIOR CLEANING BY LESSOR ..................................................................... 1798.3 NORMAL HOURS .................................................................................................................. 1868.4 BUILDING OPERATING PLAN ............................................................................................. 1868.5 OVERTIME USAGE ............................................................................................................... 1878.6 FLAG DISPLAY ..................................................................................................................... 1878.7 SECURITY ............................................................................................................................. 1878.8 VA CLEANING RESPONSIBILITY ........................................................................................ 187SECTION 9 SAFETY, FIRE PROTECTION, AND ENVIRONMENTAL MANAGEMENT ........ 1889.1 GENERAL .............................................................................................................................. 1889.1.1 PERMITS ................................................................................................................. 188Table <strong>of</strong> Contents – viiLessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]9.1.2 INSPECTIONS BY LESSOR ................................................................................... 1889.1.3 INSPECTIONS BY GOVERNMENT ........................................................................ 1889.2 CODE VIOLATIONS .............................................................................................................. 1889.3 SPECIAL ENVIRONMENTAL REQUIREMENTS .................................................................. 1899.3.1 INDOOR ENVIRONMENT ....................................................................................... 1899.3.2 SPECIAL BUILDING EQUIPMENT ......................................................................... 189SECTION 10 INSTRUCTIONS AND PREPARATION ............................................................... 19010.1 NOTICE TO OFFERORS ...................................................................................................... 19010.2 DEVIATIONS ......................................................................................................................... 19010.3 ERASURES OR CHANGES .................................................................................................. 19010.4 COMPLETION OF GSA FORM 3518 .................................................................................... 19010.5 PREPARATION OF GSA FORM 1217 .................................................................................. 19010.6 PREPARATION OF GSA FORM 1364A (Revised 5/98) ....................................................... 19110.7 DRAWINGS AND SPECIFICATIONS – SUBMISSION WITH OFFER ................................. 19210.7.2 SITE PLAN(S) .......................................................................................................... 19210.7.3 FLOOR PLAN(S) ...................................................................................................... 19310.7.4 ELEVATIONS ........................................................................................................... 19310.7.5 COLOR RENDERINGS ........................................................................................... 19310.7.6 SPECIFICATIONS ................................................................................................... 19310.8 DESIGN CONCEPT: SUBMISSION WITH OFFER .............................................................. 19410.8.1 ARCHITECTURE/STRUCTURAL ............................................................................ 19410.8.2 SUSTAINABLE DESIGN AND ENERGY EFFICIENCY .......................................... 19410.8.3 FIRE PROTECTION ................................................................................................ 19410.8.4 MECHANICAL .......................................................................................................... 19410.8.5 ELECTRICAL ........................................................................................................... 19510.8.6 STRUCTURED CABLING ........................................................................................ 19510.8.7 SECURITY ............................................................................................................... 19510.8.8 AUDIO VISUAL ........................................................................................................ 19510.8.9 SPECIAL SYSTEMS ................................................................................................ 19510.8.10 PHYSICAL SECURITY MEASURES ....................................................................... 19510.8.11 WATER DISTRIBUTION .......................................................................................... 19610.8.12 SANITARY SEWERAGE SYSTEM ......................................................................... 19610.9 CALCULATIONS: SUBMISSION WITH OFFER ................................................................... 19610.9.1 AREA COMPUTATIONS ......................................................................................... 19610.9.2 HVAC CALCULATIONS ........................................................................................... 19610.9.3 ELECTRICAL CALCULATIONS .............................................................................. 196PART II.SECTION 1SCHEDULE AOPERATION AND MAINTENANCE PLANMAINTENANCE COST WORKSHEETPROPERTY MANAGEMENT AGREEMENTPART III. SCHEDULE B—SPECIAL REQUIREMENTSSECTION 1 INSTRUCTIONS FOR PRICING THIS SCHEDULE ................................................. 3SECTION 2 GENERAL INFORMATION AND INSTRUCTIONS FOR USERS ............................ 4SECTION 3 SPECIAL ITEMS FOR THE ENTIRE CLINICTable <strong>of</strong> Contents – viiiLessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]3.1 PUBLIC ADDRESS SYSTEM .................................................................................................... 53.2 AUDIO VISUAL, NURSE CALL, AND CODE ONE (BLUE) SYSTEM ...................................... 53.3 MASTER ANTENNA TELEVISION (BROADBAND) SYSTEM ................................................. 53.4 SECURITY MANAGEMENT AND CONTROL, AND CENTRALIZED POLICE SECURITYMANAGEMENT SYSTEMS ....................................................................................................... 53.5 PATIENT (ALSO STAFF) ANNUNCIATOR/LOCATOR SYSTEM ............................................ 53.6 MOTION INTRUSION DETECTOR (MID) ................................................................................. 53.7 RADIO ENTERTAINMENT DISTRIBUTION (RED) .................................................................. 63.8 DURESS ALARM AND EMERGENCY NOTIFICATION SYSTEM ........................................... 63.9 RADIO PAGING SYSTEM ......................................................................................................... 63.10 TWO-WAY RADIO SYSTEM ..................................................................................................... 63.11 SECURITY SURVEILLANCE TELEVISION (SSTV) ................................................................. 63.12 INTERCOMMUNICATION SYSTEM ......................................................................................... 63.13 VIDEO TELECONFERENCING SYSTEM (VTEL) .................................................................... 63.14 VA SATELLITE TV SYSTEM ..................................................................................................... 63.15 ELECTRONIC ACCESS OR DOOR CONTROL SYSTEM ....................................................... 7SECTION 4 SPECIAL EQUIPMENT BY FUNCTIONAL AREA ................................................... 84.1 FUNCTIONAL AREAS ............................................................................................................... 84.2 FUNCTIONAL ROOM LISTING ................................................................................................. 9SECTION 5 SUMMARY PRICE SHEET ..................................................................................... 59PART IV. SCHEDULE C—UNIT COSTS & PRICESEXHIBIT A--UNIT COSTS (TO BE USED DURING CONSTRUCTION PERIOD)EXHIBIT B--UNIT PRICES (ADDITIONAL TI RATES – FIRST YEAR)PART V.SCHEDULE D—BID SUMMARY FORMPART VI.SCHEDULE E—ROOM FINISH, DOOR & HARDWARESECTION 1 ROOM FINISHES, DOOR AND HARDWARE SCHEDULE ..................................... 31.1 ROOM FINISHES, DOOR AND HARDWARE SCHEDULE ...................................................... 31.1.1 USE OF SCHEDULE E ................................................................................................ 31.1.2 OTHER REQUIREMENTS ........................................................................................... 51.1.3 WALLCOVERING PROTECTIVE (WP), RIGID PVC SHEET ..................................... 51.1.4 STAIRWAYS ................................................................................................................ 51.2 DOORS ...................................................................................................................................... 51.2.1 DOORS ........................................................................................................................ 51.2.2 DOOR TYPES .............................................................................................................. 71.2.3 DOOR SIZES ............................................................................................................... 81.2.4 LEAD LINED DOORS AND FRAMES// ....................................................................... 91.3 FINISH HARDWARE ............................................................................................................... 101.3.1 GENERAL .................................................................................................................. 101.3.2 BUTT HINGES ........................................................................................................... 101.3.3 CONTINUOUS HINGES ............................................................................................ 111.3.4 DOOR CLOSING DEVICES ...................................................................................... 121.3.5 DOOR STOPS ........................................................................................................... 12Table <strong>of</strong> Contents – ixLessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]1.3.6 LOCKS AND LATCHES ............................................................................................. 131.3.7 PUSH-BUTTON COMBINATION LOCKS ................................................................. 131.3.8 ELECTROMAGNETIC LOCKS .................................................................................. 141.3.9 CARD READERS ....................................................................................................... 141.3.10 ELECTRIC STRIKES ................................................................................................. 151.3.11 KEYS .......................................................................................................................... 151.3.12 KEY CABINET ........................................................................................................... 151.3.13 ARMOR PLATES, COMBINATION KICK-MOP PLATES AND DOOR EDGING ...... 161.3.14 EXIT DEVICES .......................................................................................................... 171.3.15 WEATHERSTRIPS (FOR EXTERIOR DOORS) ....................................................... 171.3.16 MISCELLANEOUS HARDWARE .............................................................................. 171.3.17 PADLOCKS FOR VARIOUS DOORS, GATES AND HATCHES .............................. 171.3.18 HARDWARE SETS .................................................................................................... 18PART VII.LABOR STANDARDS PROVISIONPART VIII.FORMSPROPOSAL TO LEASE SPACE (FORM 1364A)PROPOSAL TO LEASE SPACE GUIDANCE)PAST PERFORMANCE SURVEY FORMCERTIFICATE OF CURRENT COST OF PRICING DATACERTIFICATION OF BUILDING ENERGY PERFORMANCEPART IX.CONCEPTUAL PLANSPART X.SITE SPECIFIC INFORMATIONPART XI.SCHEDULE F VA FURNISHED EQUIPMENT GUIDE LISTTable <strong>of</strong> Contents – xLessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]PART IBASIC SOLICITATION REQUIREMENTSPart I: Basic Solicitation Requirements – Page 1 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]PART I. BASIC SOLICITATION REQUIREMENTSSECTION 1 SUMMARY1.1 AMOUNT AND TYPE OF SPACEThe Department <strong>of</strong> Veterans Affairs (VA) is proposing to lease a minimum <strong>of</strong> [ _______ ] to amaximum <strong>of</strong> [ _______ ] Net Usable Square Feet (NUSF) <strong>of</strong> space for use by VA forpersonnel, furnishings, and equipment. Space shall be located in a quality //new// building,constructed <strong>of</strong> sound and substantial construction, and shall be in compliance with all <strong>of</strong> theGovernment’s minimum requirements set forth in this Solicitation for Offers (Solicitation or<strong>SFO</strong>). Space must be adjoining //and be located on one floor.// //and be on no more than two(2) contiguous floors.//Detailed definition <strong>of</strong> Net Usable Square Feet can be found in Paragraph 3.14 <strong>of</strong> thisSolicitation. Unless otherwise noted, all references in this <strong>SFO</strong> to square feet shallmean Net Usable Square Feet.1.2 SITE LOCATION//The site is located at [___________________]. A plat and legal description can be found aspart <strong>of</strong> the Assignable Option to Purchase, which is located in the Site Specific section <strong>of</strong> thisSolicitation.Property is not within the 100-year base flood plain as defined and certified by FEMA and/orthe local jurisdictions.////To be considered, the site <strong>of</strong>fered must be within the following delineated area:[insert boundary description]Property within the 100-year base flood plain as determined by FEMA shall not beconsidered.//1.3 QUALITY OF SPACEThe Offeror shall design and construct a building to suit the Government’s requirements.//The Government may consider space in existing buildings <strong>of</strong> sound and substantialconstruction which can be made adaptable as modern <strong>of</strong>fice and outpatient space. If not in anew building, the space <strong>of</strong>fered must be in a building that has undergone, or will undergo byoccupancy, restoration <strong>of</strong> adaptive reuse for <strong>of</strong>fice and outpatient space with modernconveniences. If the restoration work is underway or proposed, then design or constructiondocuments acceptable to the Contracting <strong>Office</strong>r must be submitted as part <strong>of</strong> the <strong>of</strong>fer.Acceptability <strong>of</strong> the proposed building will be judged against all the requirements <strong>of</strong> this <strong>SFO</strong>.Buildings which have incurable functional obsolescence and/or are unsuitable in configurationfor medical space floor plan layout may be rejected by the Contracting <strong>Office</strong>r.//Part I: Basic Solicitation Requirements – Page 2 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]The site, site improvements, building, interior spaces and finishes, and Lessor-furnishedequipment and special construction shall be provided in accordance with this <strong>SFO</strong>, allapplicable Federal requirements, local Building Codes and ordinances, and applicable utilitycompany requirements.Site, site improvements, building, interior construction, and equipment shall comply withGeneral Design Criteria as enumerated in SECTION 4, including Codes and Standards,criteria unique to VA, Fire, and Life Safety requirements, Environmental requirements,Accessibility Standards, OSHA requirements, and Energy Efficiency and Sustainable Design.1.3.1 QUALITY OF SITE DEVELOPMENTSite development including landscaping, site amenities, utility systems, and exterior signageshall comply with the requirements enumerated in SECTION 5 <strong>of</strong> this <strong>SFO</strong>.On-site vehicle parking spaces, paved and striped, must be provided for use by patients, staffand <strong>of</strong>ficial Government vehicles, and must be included as part <strong>of</strong> the rental consideration.The Lessor must provide the greater <strong>of</strong> the following: the number <strong>of</strong> parking spaces requiredby local building or zoning regulations, or the number <strong>of</strong> parking spaces indicated in SECTION5.Pedestrian circulation and site amenities shall be provided as required by SECTION 5 <strong>of</strong> this<strong>SFO</strong>.1.3.2 QUALITY OF BUILDINGThe space <strong>of</strong>fered shall be <strong>of</strong> shape and dimensions that will accommodate the spaceprogram and interior functional requirements <strong>of</strong> VA Outpatient Clinic.The space <strong>of</strong>fered shall be in a building <strong>of</strong> sound and substantial construction in accordancewith the technical requirements <strong>of</strong> this solicitation.The space <strong>of</strong>fered shall be located in a new //or modern// building with facade <strong>of</strong> stone, brick,aluminum curtain wall, or other permanent materials. The exterior building materials shall besubject to technical and aesthetic review and approval <strong>of</strong> the Contracting <strong>Office</strong>r. The buildingshall be compatible with its surroundings. Overall, the building must project a pr<strong>of</strong>essional andaesthetically pleasing appearance. Building systems, interior spaces and finishes, andLessor furnished equipment and special construction shall comply with the requirementsenumerated in SECTION 6 and SECTION 7; and Schedule B and Schedule E <strong>of</strong> this <strong>SFO</strong>.1.3.3 SPECIAL REQUIREMENTSPhysical security features shall comply with requirements for "Life Safety Protected"occupancies as enumerated in this <strong>SFO</strong>.Natural disasters resistive features shall comply with the requirements enumerated inthis <strong>SFO</strong>. Sustainability and energy efficiency features shall comply with the requirementsenumerated in this <strong>SFO</strong>.Comply with Centers for Disease Control (CDC) requirements for Tuberculosis.Part I: Basic Solicitation Requirements – Page 3 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]//Comply with US Pharmacopeia Chapter for sterile preparation areas asenumerated in this <strong>SFO</strong>.//1.4 TERMProposals are invited based on a //15-year term// //15-year firm term, with one 5-year renewaloption// //20-year term//. All the terms and conditions contained herein shall prevail throughoutthe term <strong>of</strong> the lease including all renewal options.1.5 OFFER DUEOffers are due by [insert date], and must remain open until [insert date].1.6 OCCUPANCY DATEOccupancy is required by [insert date].1.7 HOW TO OFFEROffer must be received by the Contracting <strong>Office</strong>r at the location stated below, no later than4:00 PM, ET on the date specified in Paragraph 1.5 above:Express Mail or Hand DeliveredDepartment <strong>of</strong> Veterans AffairsReal Property Service (00CFM3C)ATTN: Room [#]811 Vermont Avenue, NWWashington, DC 200051.7.1 DOCUMENTS TO SUBMIT WITH OFFEROffers shall be submitted to VA at the above referenced location in two (2) separate Volumes.Offers shall be properly signed, initialed, converted to a PDF file and indexed with bookmarks,and submitted on compact discs. Each compact disc shall be marked appropriately: Volume1-Technical Proposal and Volume 2-Price Proposal.In addition to the requested number <strong>of</strong> submission packages listed below, Offerors will submitone original hard copy and one compact disc <strong>of</strong> each Volume to [VA Broker] at the aboveaddress; the original hard copy shall be properly signed, initialed, indexed and packaged in 3-ring binders marked, Volume 1-Technical Proposal and Volume 2-Price Proposal.Offers shall consist <strong>of</strong> the following documents:Part I: Basic Solicitation Requirements – Page 4 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Volume 1-Technical Proposal (6 discs) Plans, written narratives, design concept, calculations, mechanical and electricalsystems, and energy efficiency <strong>of</strong> the proposed building as described in Paragraphs10.7, 10.8, and 10.9 <strong>of</strong> the Solicitation;Building Operating Plan as described in Paragraph 8.4 <strong>of</strong> the Solicitation;Detailed Operations and Maintenance Plan narrative and completed FMA Worksheetas described in Schedule A;GSA Form 527, Contractor’s Qualifications and Financial Information;GSA Form 330, Architect-Engineer Qualifications;Past Performance Survey Form;Basic Solicitation and Amendments, if applicable;PART VI Labor Standard Provisions;GSA Form 3516A, Solicitation Provisions;3517B, General Clauses;3518, Representations and Certifications;Certification <strong>of</strong> Building Energy PerformanceA proposed sustainable checklist identifying targeted solutions to meet LEED® Silverequivalency. Along with the proposed checklist, the Offeror shall submit a briefstatement outlining how each <strong>of</strong> the LEED® credits proposed will be achieved. //Evidence <strong>of</strong> compliance with Seismic criteria as described in Paragraph 6.1STRUCTURAL <strong>of</strong> the Solicitation.// Information that addresses any other award factors which are listed in Paragraph 2.2<strong>of</strong> the Solicitation.Volume 2-Price Proposal (2 discs) GSA Form 1364A, Proposal to Lease Space;GSA Form 1217, Lessor's Annual Cost Statement; An itemized cost for all individual items in Schedule B, including Parts III, IV, and V;A list <strong>of</strong> Unit Costs for Adjustments (Part IV Schedule C Exhibit A), and a list <strong>of</strong> UnitPrices for Alterations (Part IV Schedule C Exhibit B). Refer to Paragraphs 3.2 and3.3; and Certificate <strong>of</strong> Current Cost. Two (2) hard copies <strong>of</strong> drawings and renderings as described in Paragraphs 10.7,10.8, and 10.9 in SECTION 10 INSTRUCTIONS AND PREPARATION shall beprovided.Part I: Basic Solicitation Requirements – Page 5 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Bid Summary Form (Part V Schedule D).Information that addresses any other award factors which are listed in the solicitationParagraph 2.2 <strong>of</strong> the Solicitation.1.7.2 INSTRUCTIONS AND ADDITIONAL INFORMATIONInstructions for preparation <strong>of</strong> the <strong>of</strong>fer can be found in SECTION 10 INSTRUCTIONS ANDPREPARATION <strong>of</strong> this part <strong>of</strong> the Solicitation and GSA Form 3516A, Solicitation Provisions(located in PART VII). If additional information is needed, the Contracting <strong>Office</strong>r should becontacted.[Insert Contracting <strong>Office</strong>r name and contact information]Phone: [ ]Fax: [ ]E-mail: [ ]1.7.3 OPENING OF OFFERSThere will be no public opening <strong>of</strong> the <strong>of</strong>fer, and all information will be confidential until thelease has been awarded. However, the Government may release the proposal outside theGovernment to a Government support contractor to assist in the evaluation <strong>of</strong> the proposal.Such Government contractors shall be required to protect the data from unauthorizeddisclosure. If you desire to maximize protection <strong>of</strong> information in your <strong>of</strong>fer, you may apply therestriction notice to your <strong>of</strong>fer as prescribed in the provision entitled "552.270-1(d)(1) & (2),Instructions to Offerors" (see GSA Form 3516A, Solicitation Provisions, page 3).1.8 PROPOSALS1.8.1 RENTABLE SQUARE FEETOfferors shall submit the total rentable square feet (RSF) <strong>of</strong> the building and a cost perrentable square foot. The submission <strong>of</strong> a rentable square foot cost is required for scoringpurposes to determine if the proposed lease is a capital or operating lease.NOTE: Definitions for rentable and net usable square feet are located in Paragraph 3.14RENTABLE AND NET USABLE SQUARE FEET <strong>of</strong> this solicitation.1.8.2 SPECIAL EQUIPMENTOfferors shall submit cost proposals for all special equipment requirements set forth inSchedule B.1.8.3 NET USABLE SQUARE FEET RATESFor evaluation and negotiation purposes, the <strong>of</strong>fer shall state the following on GSA Form1364A, Proposal to Lease Space:A NUSF rental rate that includes the costs <strong>of</strong> all special equipment and other requirementsdescribed in Schedule B and Janitorial.Part I: Basic Solicitation Requirements – Page 6 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]A NUSF rental rate that excludes the costs <strong>of</strong> all special equipment and other requirementsdescribed in Schedule B, but includes Janitorial.Cost per NUSF for Janitorial Services.A lump-sum payment cost for all special equipment and other requirements described inSchedule B.Offerors shall provide cost for all methods <strong>of</strong> evaluation in order to be considered for award.VA may elect the option it deems most favorable.NOTE: WHEN PRICING SCHEDULE B, THE OFFEROR MUST PROVIDE A SEPARATECOST FOR EACH LINE ITEM OF THE SPECIAL EQUIPMENT AND REQUIREMENTSDESCRIBED. ALSO, REPRESENTATIONAL PRICING OF EACH PROGRAM AREA MUSTBE PROVIDED ON THE SCHEDULE B "SUMMARY PRICE SHEET." THE SUMMARYPRICE SHEET ALSO INCLUDES A SEPARATE AREA FOR PROFIT AND OVERHEAD TOARRIVE AT A TOTAL SCHEDULE B COST. SUMMARY COST SHEET MUST BE SIGNEDBY THE OFFEROR.Offerors who do not <strong>of</strong>fer cost proposals as stated in Paragraphs 1.8.2 and 1.8.3 abovewill be rejected as unacceptable,1.9 BONDSAll sureties must be listed in the Department <strong>of</strong> Treasury Circular 570 Approved Surety List.Standard Form 24 (Bid Bond) and Standard Form 25 (Performance Bond) must be used inaccordance with FAR 28.106-1. Copies <strong>of</strong> the forms are included in PART VII <strong>of</strong> thisSolicitation or forms may be acquired by visiting the GSA Forms Library Website athttp://www.gsa.gov/Portal/gsa/ep/formslibrary.do?formType=SF. The Government shall havethe right to approve or reject any and all terms and conditions <strong>of</strong> any and all bonds obtained bythe Offeror pursuant to this Solicitation. In addition, the terms and conditions <strong>of</strong> the Bond(s)shall be subject to the prior approval <strong>of</strong> the Government.1.9.1 BID BONDTo assure the faithful execution <strong>of</strong> the terms and conditions <strong>of</strong> the agreement, each Offerorshall submit a Bid Bond with their initial <strong>of</strong>fer. Offers without Bid Bonds will not be considered.The Bond shall remain in effect until a Performance Bond becomes effective should theOfferor be successful, or until VA has notified the Offeror that his proposal is no longer underconsideration by VA. A surety company holding a certificate <strong>of</strong> authority from the Secretary <strong>of</strong>the Treasury as acceptable surety will execute the Bond. A verifax or other facsimile copy <strong>of</strong>the agent's authority to sign bonds for the Surety Company shall accompany the Bond. TheOfferor shall furnish a proposal guarantee in the form <strong>of</strong> a Bid Bond supported by good andsufficient surety acceptable to the Government. The amount <strong>of</strong> the Bid Bond guarantee shallbe in the amount <strong>of</strong> $100,000. Acceptable alternate bonding protection will be in accordancewith FAR 28.204-1 United States Bonds or Notes, or FAR 28.204-3 Irrevocable Letter <strong>of</strong> Credit(ILC). Invalid bonds may be grounds to render your proposal non-responsive and will not beeligible for an award. Once an award has been made all original Bid Bonds will be returned,except for the successful Offeror whose Bid Bond will be required to remain in full force untilsuch time as a Performance Bond has been received and accepted by the Government.Part I: Basic Solicitation Requirements – Page 7 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]1.9.2 PERFORMANCE BONDThe successful Offeror shall provide a Performance Bond for 100% <strong>of</strong> the originalcontract price no later than 60 days from VA’s final review and written approval <strong>of</strong> thecompleted construction documents. The Performance Bond shall remain in effect until theGovernment accepts the space for occupancy. The United States <strong>of</strong> America, acting throughthe Secretary <strong>of</strong> the Department <strong>of</strong> Veterans Affairs, shall be named as co-beneficiary on theBond obtained by the Offeror.1.10 DAVIS BACON WAGESThe wages to be paid during performance under this lease contract must conform to theDepartment <strong>of</strong> Labor’s General Wage Decision No. [insert number], dated [insert date], andas may be amended during the period <strong>of</strong> construction <strong>of</strong> the leased premises. A copy <strong>of</strong> thestandards is provided in PART VI <strong>of</strong> this Solicitation. It is the Lessor’s responsibility to obtainand maintain the most current rates.1.11 //SITE SELECTION CRITERIA////The Site <strong>of</strong>fered must meet the following minimum characteristics:Be able to accommodate the proposed building and provide the required amount <strong>of</strong>appropriately located parking with appropriate vehicular circulation, loading dock andservice vehicle access, emergency vehicle (ambulance) access and entry, buildingutility equipment (chillers, emergency generator, fuel tanks, etc.), safe ways <strong>of</strong>passage for pedestrians, barrier-free access to public entrances, and adequate openspace with landscaping to complement the architecture and create a pleasing outdoorenvironment.Any configurations will be considered, provided the space can adequatelyaccommodate the building program, design requirements, and designated activities.Topography shall be without steep grades and shall not be affected by the 100-yearflood plain as mapped by FEMA, rock outcroppings, or adverse subsurface conditions. Be free <strong>of</strong> environmental hazards or restrictions. A Phase 1 EnvironmentalAssessment may be requested by the Contracting <strong>Office</strong>r, if deemed necessary.Provide pro<strong>of</strong> <strong>of</strong> ownership and chain <strong>of</strong> title through a current title report. Providepro<strong>of</strong> that all encumbrances have been addressed or identified in a current title report;current within 90 days.Provide prominent visibility <strong>of</strong> the facility from major public thoroughfares.Main ingress/egress for on-site pedestrian and vehicular circulation shall be easilyaccessible from major public thoroughfares.Regularly scheduled public transportation shall be available within ¼ mile (1,320 feet)<strong>of</strong> the OPC site.Part I: Basic Solicitation Requirements – Page 8 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]// //Laboratory and x-ray// //[_____]// facilities must be available within //2 miles////[____]// <strong>of</strong> the outpatient clinic site.//[Insert other factors as necessary]//Part I: Basic Solicitation Requirements – Page 9 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]SECTION 2 COMMUNICATIONS AND AWARD2.1 //ORAL PRESENTATIONSOral presentations may be made to augment written information. Oral presentations will notbe required unless specifically requested by the Government in writing. Oral presentationsmay occur at any time during the acquisition process and are subject to the same restrictionsas written information with regard to timing and content. Information pertaining to areas suchas an Offeror’s capability to perform, past performance, key personnel resources, work planapproaches, etc., may be suitable for oral presentations. Should the Government require anoral presentation, the Offeror will be provided with (1) sufficient information to prepare them,including the types <strong>of</strong> information to be presented and the associated evaluation factors thatwill be used; (2) the qualifications for personnel that will conduct the oral presentation; (3) therequirement for, and any limitations and/or prohibitions on, the use <strong>of</strong> written material or othermedia to supplement the oral presentation; (4) the location, date, and time for the oralpresentation; (5) the restrictions governing the time permitted for each oral presentation; and(6) the scope and content <strong>of</strong> exchanges that may occur between the Government and theOfferor as part <strong>of</strong> the oral presentation.//2.2 EVALUATION OF OFFERSThe Contracting <strong>Office</strong>r will evaluate all proposals to assess the Offeror's ability to perform thecontract successfully. The evaluation will be conducted solely on the factors and sub-factorsspecified in this Solicitation which are listed in descending order <strong>of</strong> importance. All sub-factorsare also listed in descending order <strong>of</strong> importance.Evaluation <strong>of</strong> <strong>of</strong>fers and subsequent award will be made on the basis <strong>of</strong> the following factors:(1) the annual price per net usable square foot, including any option period; (2) technicalquality, including the quality <strong>of</strong> the building and the design concept; (3) the Offeror'squalifications, including past performance; and (4) the adequacy and efficiency <strong>of</strong> theOperations and Maintenance Plans.The technical evaluation factors other than cost or price, when combined, are //significantlyless important than// //more important than// //approximately equal to// cost or price.2.2.1 PRICE EVALUATIONThe basic price <strong>of</strong>fered will be the rate per Net Usable Square Foot (NUSF). Refer toParagraph 3.14 <strong>of</strong> this Solicitation for a definition <strong>of</strong> NUSF. This price shall be used todetermine the total annual rental to be paid, adjusted for any discrepancies in the quantity <strong>of</strong>space delivered against the amount <strong>of</strong>fered and accepted, as described elsewhere in thisSolicitation.Annual CPI adjustments in operating expenses will be made if the Offeror so indicates on GSAForm 1364A. The Offeror shall be required to submit the <strong>of</strong>fer with the total "gross" annualprice per NUSF and a breakout <strong>of</strong> the "base" price per NUSF for services and utilities(operating expenses) to be provided by the Lessor. The net and base prices combined arethe total "gross" annual per square foot price <strong>of</strong>fered. The base price from which adjustmentsare made will be the base price for the term <strong>of</strong> the lease, including any option periods. The"gross" price shall include the "base" price.Part I: Basic Solicitation Requirements – Page 10 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]A. Present Value Price EvaluationEvaluation <strong>of</strong> <strong>of</strong>fered prices will be on the basis <strong>of</strong> the annual price per NUSF, including anyoption periods. The Government will perform present value price evaluation by reducing theprices per NUSF to a composite annual square foot price, as follows:Parking and wareyard areas will be excluded from the total square footage, but not from theprice.The annual per square foot price minus the base cost <strong>of</strong> operating expenses (line 27 <strong>of</strong> GSAForm 1217) will be discounted annually at 4.9% to yield a net present value cost (PVC) persquare foot. The operating expenses will be both escalated at 4% compounded annually anddiscounted annually at 4.9%, then added to the net PVC to yield the gross PVC.To the gross PVC will be added: The cost <strong>of</strong> Government-provided services not included in the rental escalated at 4%compounded annually and discounted annually at 4.9%.The annualized cost per NUSF, over the full term <strong>of</strong> the lease, including the renewaloption(s), for all Schedule B items, which will be reimbursed to the Lessor by lumpsum payment. (The cost <strong>of</strong> these items is present value; therefore, it will not bediscounted.)The cost <strong>of</strong> relocation <strong>of</strong> furniture and telecommunications, if applicable.The sum <strong>of</strong> the above will be the per NUSF present value <strong>of</strong> the <strong>of</strong>fer for priceevaluation purposes.2.2.2 TECHNICAL QUALITYThe technical quality factor includes the quality <strong>of</strong> the building design and systems, sitedevelopment, and the overall design concept. The Offeror is required to submit drawings,narratives, and calculations that address this factor and all <strong>of</strong> its sub-factors. Submittalrequirements for these materials are in SECTION 10.A. Quality <strong>of</strong> Building & Design ConceptVA will evaluate the materials, systems, and design <strong>of</strong> the proposed building using thefollowing factors.(1) Architectural ConceptThis factor considers the interior functional and spatial relationships shown in the Offeror’sfloor plan. The space <strong>of</strong>fered shall be <strong>of</strong> shape and dimensions that will accommodate thespace program and interior functional requirements <strong>of</strong> VA Outpatient Clinic. Consideration willbe given to the number and size <strong>of</strong> floors, column placement, shape <strong>of</strong> footprint, circulationsystems, and placement <strong>of</strong> mechanical, plumbing, and electrical service spaces. TheContracting <strong>Office</strong>r will reject buildings that are unsuitable in configuration for VA clinic space.(2) Building DesignThe exterior design shall be subject to technical and aesthetic review and approval <strong>of</strong> theContracting <strong>Office</strong>r. The building shall be new // or modern// construction <strong>of</strong> permanentmaterials and shall be compatible with its surroundings. Acceptable facades include stone,marble, brick, stainless steel or aluminum curtain wall systems, or other permanent materials.Part I: Basic Solicitation Requirements – Page 11 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Overall, the building must project a pr<strong>of</strong>essional and aesthetically pleasing appearance. Siteand building design shall present a clear and direct entry sequence for patients and visitors.(3) Sustainable Design and Energy EfficiencyThe building envelope and systems will be evaluated for compliance with the requirements <strong>of</strong>Paragraphs 4.2.1B Mandatory Provisions for Energy Conservation and 4.8 SUSTAINABLEDESIGN AND ENERGY EFFICIENCY. Drawings, specifications, calculations, and narrative(s)submitted in accordance with SECTION 10 will be evaluated for compliance with requirementsfor sustainable design and energy efficiency. Reasonable innovation in this area will belooked upon favorably.(4) Quality <strong>of</strong> <strong>Construction</strong> Materials<strong>Construction</strong> materials and building equipment and systems will be evaluated with respect totheir performance, durability, quality, and suitability for their intended use. All materials andbuilding equipment and systems must meet or exceed the requirements <strong>of</strong> this solicitation.B. Quality <strong>of</strong> Site DevelopmentThis factor considers the Offeror’s development <strong>of</strong> the site to accommodate VA’s conceptualbuilding footprint including the required setbacks; the ingresses and egresses to and from themain (public), emergency, and staff entrances; and loading dock and service entrances;accessible parking lots and walkways; traffic patterns to maximize the flow <strong>of</strong> vehicles to andfrom the main thoroughfare; and how the landscaping design fits the surrounding areas,adheres to local landscaping codes, and provides an aesthetically pleasing atmosphere.C. Site Physical SecurityA physical security plan will be provided that provides summary information used to describesafeguard and security programs and vulnerability and risk assessments to the facility. Theplan’s intent is to assist with management <strong>of</strong> facility program elements and resources relatedto threats and risks. Provide detailed information <strong>of</strong> facility security program, equipment, andstrategies. Plan should include at a minimum:Definition <strong>of</strong> assumed threat against which the system is providing protectionRisk and VA assessmentConclusions and assumptionsProtection strategyGraded postures for increased threat conditionsImplementing requirements and evidence files.This plan should be reviewed and modified as necessary every 12 months and submitted formanagement review.2.2.3 OPERATIONS AND MAINTENANCE PLANThe following evaluation criteria will consider the adequacy and efficiency <strong>of</strong> the proposedOperations and Maintenance Plan to maintain standards <strong>of</strong> cleanliness, orderliness, and repairfor the entire proposed facility. Each sub-factor must be addressed in narrative or chartformat. The Plan will be evaluated as a whole and must address at a minimum:Interior and Exterior Maintenance <strong>of</strong> Building and GroundsRoutine and Emergency Calls - Procedures and Response TimesPart I: Basic Solicitation Requirements – Page 12 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Staffing Plan, Administrative Procedures, and Quality Control Plan2.2.4 EVIDENCE OF CAPABILITY TO PERFORM PRIOR TO AWARDAt the time <strong>of</strong> submission <strong>of</strong> <strong>of</strong>fers, Offerors shall submit to the Contracting <strong>Office</strong>r:A. Past PerformanceInclude the following information for each contract and subcontract performed by the Offerorand key personnel during the past three (3) years, as well as those contracts and subcontractscurrently in progress. A separate record must be completed for each contract andsubcontract. A Past Performance Survey Form is located in the FORMS part <strong>of</strong> this <strong>SFO</strong> andincludes the following: Name and Address <strong>of</strong> Contracting Activity Contract Number Type <strong>of</strong> Contract Total Contract Amount and Status Date <strong>of</strong> Award and Date <strong>of</strong> Completion Description and Location <strong>of</strong> Contract Work List <strong>of</strong> Major Subcontractors Contracting <strong>Office</strong>r or Individual Responsible for Signing Contract and Telephone/FAXNumbers Project Manager and Telephone/FAX Numbers Resident Engineer/Contracting <strong>Office</strong>r’s Technical Representative or <strong>Construction</strong>Supervisor and Telephone/FAX Numbers Administrative Contracting <strong>Office</strong>r or Individual Responsible for Administering theContract (if different from Contracting <strong>Office</strong>r above) and Telephone/FAX NumbersThe Offeror must provide examples <strong>of</strong> past performance and experience, as a primecontractor, in successfully building, renovating, and maintaining facilities comparable in sizeand complexity to the one described in this Solicitation. Consideration will be given to:Timeliness <strong>of</strong> PerformanceCost ControlEffective <strong>Management</strong>Customer SatisfactionQuality AwardsThe Technical Success <strong>of</strong> the ProjectThe Offeror must also provide a list <strong>of</strong> references for the Offeror, key personnel, andconstruction contractor. References may be business, financial, and/or personal, and mayinclude letters <strong>of</strong> recommendation or commendation, awards or certifications that indicateOfferor possesses a high quality process for developing and providing the final project orservice.The Offeror must submit the name and qualifications <strong>of</strong> the proposed CommissioningProvider. Include relevant experience and references. The Commissioning Provider must beapproved by the Contracting <strong>Office</strong>r.Part I: Basic Solicitation Requirements – Page 13 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]B. Financial ResourcesProvide satisfactory evidence <strong>of</strong> at least a conditional commitment <strong>of</strong> funds in an amountnecessary to prepare and/or construct the space. Such commitment must be signed by anauthorized bank <strong>of</strong>ficer or other financial institution and, at a minimum, must state:Amount <strong>of</strong> LoanTerm in YearsAnnual Percentage RateLength <strong>of</strong> Loan CommitmentName <strong>of</strong> the Principal(s) InvolvedThe Purpose <strong>of</strong> the LoanIn the case an Offeror is requested to submit a Best and Final Offer, the Offeror shall submitevidence <strong>of</strong> a firm commitment <strong>of</strong> funds in an amount sufficient to perform the work with thefinal <strong>of</strong>fer.With the initial <strong>of</strong>fer, provide satisfactory evidence <strong>of</strong> financial resources sufficient to prosecutethe work. Such evidence may be one <strong>of</strong> the following:A Statement <strong>of</strong> Financial ConditionPersonal or Business Financial Statements, including Balance Sheets, and Pr<strong>of</strong>it andLoss StatementsInvestment ScheduleNote Payable SchedulePrevious Year's Federal Tax ReturnAnnual ReportIf requested, more information must be provided.C. Design Team QualificationsProvide a completed SF 330, "Architect-Engineer Qualifications" for each individual or firm onthe Lessor’s design team. Identify key personnel that are to be committed to the project. InPart I, Section H <strong>of</strong> SF 330, provide a description <strong>of</strong> outstanding commitments for each firmand key personnel. As a minimum, the design team shall include entities providing thefollowing services: Architecture, Civil Engineering, Mechanical Engineering, Fire Protection,Electrical Engineering, Interior Design, and appropriate Low Voltage Engineering (StructuredTelecommunications Cabling, Security, Audio Visual, and Special Systems).Provide a copy <strong>of</strong> the license or certification <strong>of</strong> the individual(s) and/or firm(s), providingarchitectural and engineering design services, proving their ability to practice in the statewhere the facility is located. Low-voltage designers shall be BICSI-certified for structuralcabling, and shall have OEM credentials for the Special Systems listed in 6.8.1.G, SpecialSystems Specific Requirements.Lessor shall maintain the same design team for the duration <strong>of</strong> the design development andconstruction process. Design team firm and key personnel shall not be changed without priorapproval by the Contracting <strong>Office</strong>r.Part I: Basic Solicitation Requirements – Page 14 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]D. Contractor QualificationsProvide a completed GSA Form 527, "Contractor’s Qualifications and Financial Information"for the General Contractor, Mechanical Contractor, and Electrical Contractor; except Section Vneed not be completed. In Section VII <strong>of</strong> Form 527, provide a description <strong>of</strong> outstandingcommitments, names and qualifications <strong>of</strong> key personnel, and any other information related toexperience, competency, and performance capabilities with construction projects similar inscope to that which is required herein. (Refer to 2.2.4A Past Performance requirements asstated above.)Provide a copy <strong>of</strong> the license in the state where the facility is located for the individual(s)and/or firm(s) proposed as contractors. If the Lessor is also the Contractor, informationprovided in response to paragraphs Past Performance and Financial Resources above neednot be duplicated.2.2.5 ZONING REQUIREMENTS//Provide evidence <strong>of</strong> compliance with local zoning laws or evidence <strong>of</strong> variance, if any,approved by the proper local authority. Provide evidence <strong>of</strong> compliance with any specificzoning conditions that may be required in order to develop the property. At the discretion <strong>of</strong>the Contracting <strong>Office</strong>r, other forms <strong>of</strong> documentation demonstrating the probability <strong>of</strong>receiving such variances may be acceptable.//2.2.6 CONTROL OF PROPERTY//Provide written documentation that you will comply with the assignable option for purchase//lease/// <strong>of</strong> the land and any covenants and declarations associated with the land.////Provide documentation proving evidence <strong>of</strong> ownership or control <strong>of</strong> the site. Ownership orcontrol must, at a minimum, be until the Government vacates the premises. Documentationthat constitutes evidence <strong>of</strong> control includes, but is not limited to:An Option To PurchaseA Sales ContractA Fee Simple DeedAn Option To Lease Property For Longer Than the Duration <strong>of</strong> the Lease TermIncluding All Renewal Options//2.3 EVIDENCE OF CAPABILITY TO PERFORM AFTER AWARDWithin //60// //90// calendar days after award, the successful Offeror/Lessor shall provide theContracting <strong>Office</strong>r with evidence <strong>of</strong> the following:A firm commitment <strong>of</strong> funds in an amount sufficient to perform the work.Satisfactory title showing fee simple ownership <strong>of</strong> the property, or an option to lease propertyfor longer than the duration <strong>of</strong> the lease term, including all renewal options. Fee simple title oroption to lease must be free <strong>of</strong> any encumbrances that may limit the rights, responsibilities orliabilities <strong>of</strong> the parties to the VA lease.Part I: Basic Solicitation Requirements – Page 15 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]FAILURE TO MEET ANY OR ALL OF THE REQUIREMENTS AS SET FORTH INPARAGRAPHS 2.2.4 AND 2.3 INCLUDING SUB-PARAGRAPHS, WITHIN THE SPECIFIEDTIMEFRAMES SHALL BE A BASIS FOR DETERMINATION OF NON-RESPONSIBILITYOR FOR TERMINATION OF THE CONTRACT FOR DEFAULT.FAILURE ON THE PART OF THE GOVERNMENT TO ENFORCE ITS RIGHTS TODECLARE A DEFAULT WILL NOT BE DEEMED A WAIVER OF ANY OF THEGOVERNMENT'S RIGHTS UNDER THIS SOLICITATION.2.4 INITIAL OFFERS; COMMUNICATIONS WITH OFFERORSVA may initiate action to award a contract at any point after review <strong>of</strong> the initial <strong>of</strong>fers.Therefore, <strong>of</strong>fers should reflect the Offeror’s best terms both from a technical and coststandpoint.After receipt and evaluation <strong>of</strong> initial proposals, the Contracting <strong>Office</strong>r may communicate withOfferors to establish the competitive range. Communications shall be limited to Offerors:Whose past performance information is the determining factor preventing themfrom being placed within the competitive rangeWhose exclusion from, or inclusion in, the competitive range is uncertain2.5 COMPETITIVE RANGEAfter evaluating all proposals in accordance with Paragraph 2.2 above based on the ratings <strong>of</strong>each proposal against all evaluation criteria, if the Contracting <strong>Office</strong>r cannot make an award,a competitive range comprised <strong>of</strong> all the most highly rated proposals will be established. If theContracting <strong>Office</strong>r determines that the number <strong>of</strong> proposals that would otherwise be in thecompetitive range exceeds the number at which an efficient competition can be conducted, theContracting <strong>Office</strong>r may limit the number <strong>of</strong> proposals in the competitive range to the greatestnumber that will permit an efficient competition among the most highly rated proposals.2.6 NEGOTIATIONSVA will negotiate only with those Offerors who have been placed in the competitive range asestablished under procedures at Paragraph 2.5 above. VA Contracting <strong>Office</strong>r will conductnegotiations on behalf <strong>of</strong> the Government in order to obtain the best value to the Government.Other VA personnel, including the Contracting <strong>Office</strong>r’s Representative named on the cover <strong>of</strong>this Solicitation, may assist the Contracting <strong>Office</strong>r.2.7 AWARD2.7.1 BEST VALUEThe lease will be awarded to the Offeror whose <strong>of</strong>fer represents the best value to theGovernment, price and other factors considered. For this procurement, price is //equal to////less important than // //more important than// technical factors. An award will be made basedon a comparative assessment <strong>of</strong> proposals against all selection criteria in the Solicitation.Part I: Basic Solicitation Requirements – Page 16 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]To be considered for award, an Offeror must agree to provide a complete facility that meets alltechnical requirements and specifications set out in this Solicitation. The requirements andspecifications contained in this Solicitation are mandatory.2.7.2 LEASE COMPONENTSAt a minimum, the proposed lease shall consist <strong>of</strong>:Standard Form 2 - U.S. Government Lease for Real PropertyForm 35l7B, General ClausesForm 35l8, Representations and CertificationsForm 3516A, Solicitation ProvisionsProperty <strong>Management</strong> AgreementAll the provisions <strong>of</strong> the <strong>SFO</strong>The pertinent provisions <strong>of</strong> the <strong>of</strong>ferNOTE: For purposes <strong>of</strong> release <strong>of</strong> information under the Freedom <strong>of</strong> Information Act (FOIA) orother applicable statutes or regulations, the individual itemized costs as set forth inSchedule B and other proprietary information are considered procurement-sensitiveinformation and are not subject to release.2.7.3 AWARDThe award by the Government occurs upon execution <strong>of</strong> the lease by VA Contracting <strong>Office</strong>rand issuance <strong>of</strong> a letter by VA Contracting <strong>Office</strong>r indicating that the Government accepts theOfferor’s proposal.If an award is not made based on the initial proposals, the following process will occur:Each Offeror still in the competitive range will be given an opportunity to submit a "finalproposal revision" to clarify and document understandings reached during negotiations. Oncefinal proposal revisions are received, all discussions will cease.After the conclusion <strong>of</strong> negotiations and a review <strong>of</strong> final proposal revisions are completed, theContracting <strong>Office</strong>r may award the lease.Part I: Basic Solicitation Requirements – Page 17 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]SECTION 3 MISCELLANEOUS3.1 SUBSTITUTIONS FOR SPECIFIC BRAND NAMESWhen specific equipment is cited using the brand name, model number, etc., a comparable orequal product may be provided in lieu <strong>of</strong> cited equipment in accordance with the Brand Nameclause provided in Schedule B <strong>of</strong> the Solicitation. Any substitutions need to be approved bythe Contracting <strong>Office</strong>r or his/her designee.3.2 UNIT COSTS FOR ADJUSTMENTSSchedule E <strong>of</strong> this Solicitation indicates various types <strong>of</strong> materials anticipated for floors, walls,and ceilings. Additionally, several paragraphs in this Solicitation specify means fordetermining quantities <strong>of</strong> materials not specified in Schedule E. Government projections <strong>of</strong>these various materials have been made to assist the Offeror in cost estimating and havebeen included on Section 1 <strong>of</strong> Schedule C. Actual quantities may not be determined until afterthe lease is awarded and the space layout completed. To enable an equitable settlement ifthe final Government layout departs from the projection, the quantities specified on Section 1<strong>of</strong> Schedule C are to be included in the per square foot rate being proposed. A unit cost foreach <strong>of</strong> these materials is required. VA will use each unit cost to make a lump sum paymentat time <strong>of</strong> acceptance <strong>of</strong> the building or to negotiate a rental increase if the amount <strong>of</strong> materialrequired by the layout is more than specified. If the amount <strong>of</strong> material is less than specified,VA will take credit from the initial rental payment.3.3 UNIT PRICES FOR ALTERATIONS OF $100,000 OR LESSThe Offeror is required to submit a list <strong>of</strong> "Unit Prices for Alterations" for any alterationsrequired during the first year. This list will be used, after acceptance by VA, for contracts foralterations costing $100,000 or less. These prices may be indexed or re-negotiated to applyto subsequent years <strong>of</strong> the lease upon mutual agreement <strong>of</strong> the Lessor and Government.(Use Schedule C for this purpose.)Prices for changes in quantities <strong>of</strong> the types or styles <strong>of</strong> finish materials requested by theGovernment shall be computed using the unit costs for the materials in question fromSection 1 <strong>of</strong> Schedule C.Where unit prices for alterations are not available, the Lessor may be requested to provide aprice proposal for the alterations. Orders will be placed by issuance <strong>of</strong> a GSA Form 276,Supplemental Lease Agreement. The clauses entitled "GSAR 552.232-75, Prompt Payment(SEP 1999)," "GSAR 552.232-70, Invoice Requirements (Variation) (SEP 1999)," and "GSAR552.232-76, Electronic Funds Transfer Payment (MAR 2000) (Variation)" apply to orders foralterations (See GSA Form 35l7B). All orders are subject to the terms and conditions <strong>of</strong> thelease.Orders may be placed by the Contracting <strong>Office</strong>r or other authorized representatives whenspecifically authorized to do so by the Contracting <strong>Office</strong>r. The Contracting <strong>Office</strong>r will providethe Lessor with a list <strong>of</strong> agency <strong>of</strong>ficials authorized to place orders and will specify anylimitations on the authority delegated to agency <strong>of</strong>ficials. The agency <strong>of</strong>ficials are notauthorized to deal with the Lessor on any other matters.Part I: Basic Solicitation Requirements – Page 18 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]3.4 SPECIAL WORK (INSTALLATIONS AND ALTERATIONS)The Government may require special installations in the space, such as computer rooms,vaults, or laboratories containing special air conditioning and heating controls, flooring andvarious electrical, plumbing, and mechanical facilities, and equipment not otherwise specifiedin this Solicitation. The Government reserves the right to contract separately for suchfacilities, equipment and/or installations; or it may require the Offeror to perform such work. Inthe event the Government requires the Offeror to complete such installations, the Offeror willbe required to submit a cost estimate to the Contracting <strong>Office</strong>r within 30 days after receipt <strong>of</strong>complete specifications for the special installation.If the Government contracts with the Offeror to effect such installations, payment will be madeon a lump-sum basis or through increased rental payments at the Government's option.(Increased rental payments will recognize residual values to the Owner and will includeinterest, if any, at a rate not in excess <strong>of</strong> the first mortgage.) In connection therewith, thesuccessful Offeror will be required to accomplish such work on an actual cost basis, and theGovernment payment, therefore, will be computed on the basis <strong>of</strong> such.The successful Offeror will be required to submit, not later than 30 days prior to the date <strong>of</strong>delivery and occupancy <strong>of</strong> the space and every year thereafter during the term <strong>of</strong> the lease,unit prices for such repetitive alteration work items such as (1) installation <strong>of</strong> electrical outlets,(2) installation <strong>of</strong> telephone/data outlets, (3) erection and/or relocation <strong>of</strong> movable partitions,(4) lighting changes, and (5) special painting.3.5 TAX ADJUSTMENTS3.5.1 PURPOSEThis paragraph provides for adjustment in the rent ("Tax Adjustment") to account for increasesor decreases in Real Estate Taxes for the Property after the establishment <strong>of</strong> the Real EstateTax Base, as those terms are defined herein. Tax Adjustments shall be calculated inaccordance with this Clause.3.5.2 DEFINITIONSThe following definitions apply to the use <strong>of</strong> capitalized terms within this paragraph:"Property" is the land, buildings and other improvements <strong>of</strong> which the premises (as fullydescribed in the U.S. Government Lease for Real Property, SF2) form all or a part."Real Estate Taxes" are those taxes that are levied upon the owners <strong>of</strong> real property by aTaxing Authority (as hereinafter defined) <strong>of</strong> a State or Local Government on an ad valorembasis to raise general revenue for funding the provision <strong>of</strong> government services. The termexcludes, without limitation, special assessments for specific purposes, assessments forbusiness improvement districts, and/or community development assessments."Taxing Authority" is a State, Commonwealth, Territory, County, City, Parish, or politicalsubdivision there<strong>of</strong>, authorized by law to levy, assess, and collect Real Estate Taxes."Tax Year" refers to the 12-month period adopted by a Taxing Authority as its fiscal year forthe purpose <strong>of</strong> assessing Real Estate Taxes on an annual basis.Part I: Basic Solicitation Requirements – Page 19 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]"Tax Abatement" is an authorized reduction in the Lessor's liability for Real Estate Taxesbelow that determined by applying the generally applicable Real Estate Tax rate to the FullyAssessed (as hereinafter defined) valuation <strong>of</strong> the Property."Unadjusted Real Estate Taxes" are the full amount <strong>of</strong> Real Estate Taxes that would beassessed for the Property for one full Tax Year without regard to the Lessor's entitlement toany Tax Abatements (except if such Tax Abatement came into effect after the date <strong>of</strong> award <strong>of</strong>the Lease), and not including any late charges, interest, or penalties. If a Tax Abatementcomes into effect after the date <strong>of</strong> award <strong>of</strong> the Lease, "Unadjusted Real Estate Taxes" are thefull amount <strong>of</strong> Real Estate Taxes assessed for the Property for one full Tax Year, less theamount <strong>of</strong> such Tax Abatement, and not including any late charges, interest, or penalties."Real Estate Tax Base" is the Unadjusted Real Estate Taxes for the first full Tax Yearfollowing the commencement <strong>of</strong> the Lease term. If the Real Estate Taxes for that Tax Yearare not based upon a Full Assessment <strong>of</strong> the Property, then the Real Estate Tax Base shall bethe Unadjusted Real Estate Taxes for the Property for the first full Tax Year for which the RealEstate Taxes are based upon a Full Assessment. Such first full Tax Year may be hereinafterreferred to as the "Tax Base Year." Alternatively, the Real Estate Tax Base may be an amountnegotiated by the parties that reflects an agreed-upon base for a Fully Assessed value <strong>of</strong> theproperty.The Property is deemed to be "Fully Assessed" (and Real Estate Taxes are deemed to bebased on a "Full Assessment") only when a Taxing Authority has, for the purpose <strong>of</strong>determining the Lessor's liability for Real Estate Taxes, determined a value for the Property,taking into account the value <strong>of</strong> all improvements contemplated for the Property pursuant tothe Lease, and issued to the Lessor a tax bill or other notice <strong>of</strong> levy wherein the Real EstateTaxes for the full Tax Year are based upon such Full Assessment. At no time prior to theissuance <strong>of</strong> such a bill or notice shall the Property be deemed Fully Assessed."Percentage <strong>of</strong> Occupancy" refers to that portion <strong>of</strong> the Property exclusively occupied or usedby the Government pursuant to the Lease. For buildings, the Percentage <strong>of</strong> Occupancy isdetermined by calculating the ratio <strong>of</strong> the rentable square feet occupied by the Governmentpursuant to the Lease to the total rentable square feet in the building or buildings so occupied,and shall not take into account the Government's ancillary rights including, but not limited to,parking or ro<strong>of</strong> space for antennas (unless facilities for such ancillary rights are separatelyassessed). This percentage shall be subject to adjustment to take into account increases ordecreases in the amount <strong>of</strong> space leased by the Government or in the amount <strong>of</strong> rentablespace on the Property.3.5.3 ADJUSTMENT FOR CHANGES IN REAL ESTATE TAXESAfter the Property is Fully Assessed, the Government shall pay its share <strong>of</strong> any increases andshall receive its share <strong>of</strong> any decreases in the Real Estate Taxes for the Property, such share<strong>of</strong> increases or decreases to be referred to herein as "Tax Adjustment." The amount <strong>of</strong> the TaxAdjustment shall be determined by multiplying the Government's Percentage <strong>of</strong> Occupancy bythe difference between the current year Unadjusted Real Estate Taxes and the Real EstateTax Base, less the portion <strong>of</strong> such difference not paid due to a Tax Abatement (except if a TaxAbatement comes into effect after the date <strong>of</strong> award <strong>of</strong> the Lease). If a Tax Abatement comesinto effect after the date <strong>of</strong> award <strong>of</strong> the Lease, the amount <strong>of</strong> the Tax Adjustment shall bedetermined by multiplying the Government's Percentage <strong>of</strong> Occupancy by the differencebetween the current year Unadjusted Real Estate Taxes and the Real Estate Tax Base. ThePart I: Basic Solicitation Requirements – Page 20 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Government shall pay the Tax Adjustment in a single annual lump sum payment to the Lessor.In the event that this Tax Adjustment results in a credit owed to the Government, theGovernment may elect to receive payment in the form <strong>of</strong> a rental credit or lump sum payment.If the Property contains more than one separately assessed parcel, then more than one TaxAdjustment shall be determined based upon the Percentage <strong>of</strong> Occupancy, Real Estate TaxBase, and Real Estate Taxes for each respective parcel.After commencement <strong>of</strong> the Lease term, the Lessor shall provide to the Contracting <strong>Office</strong>rcopies <strong>of</strong> all Real Estate Tax Bills for the Property, all documentation <strong>of</strong> Tax Abatements,credits, or refunds, if any, and all notices which may affect the assessed valuation <strong>of</strong> theProperty, for the Tax Year prior to the commencement <strong>of</strong> the Lease Term, and all suchdocumentation for every year following. Lessor acknowledges that the Contracting <strong>Office</strong>rshall rely on the completeness and accuracy <strong>of</strong> these submissions in order to establish theReal Estate Tax Base and to determine Tax Adjustments. The Contracting <strong>Office</strong>r maymemorialize the establishment <strong>of</strong> the Real Estate Tax Base by issuing a unilateraladministrative Supplemental Lease Agreement indicating the Base Year, the amount <strong>of</strong> theReal Estate Tax Base, and the Government's Percentage <strong>of</strong> Occupancy.The Real Estate Tax Base is subject to adjustment when increases or decreases to RealEstate Taxes in any Tax Year are attributable to a) improvements or renovations to theProperty not required by this Lease, or b) changes in net operating income for the Property notderived from this Lease. If either condition results in a change to the Real Estate Taxes, theContracting <strong>Office</strong>r may re-establish the Real Estate Tax Base as the Unadjusted Real EstateTaxes for the Tax Year the Property is reassessed under such condition, less the amount bywhich the Unadjusted Real Estate Taxes for the Tax Year prior to reassessment exceeds theprior Real Estate Tax Base.If this Lease includes any options to renew the term <strong>of</strong> the Lease, or be otherwise extended,the Real Estate Tax Base for the purpose <strong>of</strong> determining Tax Adjustments during the renewalterm or extension shall be the last Real Estate Tax Base established during the base term <strong>of</strong>the Lease.If any Real Estate Taxes for the Property are retroactively reduced by a Taxing Authorityduring the term <strong>of</strong> the Lease, the Government shall be entitled to a proportional share <strong>of</strong> anytax refunds to which the Lessor is entitled, calculated in accordance with this Clause.Lessor acknowledges that it has an affirmative duty to disclose to the Government anydecreases in the Real Estate Taxes paid for the Property during the term <strong>of</strong> the Lease. Lessorshall annually provide to the Contracting <strong>Office</strong>r all relevant tax records for determiningwhether a Tax Adjustment is due, irrespective <strong>of</strong> whether it seeks an adjustment in any TaxYear.If the Lease terminates before the end <strong>of</strong> a Tax Year, or if rent has been suspended, paymentfor the Real Estate Tax increase due as a result <strong>of</strong> this section for the Tax Year will beprorated based on the number <strong>of</strong> days that the Lease and the rent were in effect. Any creditdue the Government after the expiration or earlier termination <strong>of</strong> the Lease shall be made by alump sum payment to the Government or as a rental credit to any succeeding lease, asdetermined in the Contracting <strong>Office</strong>r's sole discretion. Lessor shall remit any lump sumpayment to the Government within 15 calendar days <strong>of</strong> payment or credit by the TaxingAuthority to Lessor or Lessor’s designee. If the credit due to the Government is not paid bythe due date, interest shall accrue on the late payment at the rate established by the SecretaryPart I: Basic Solicitation Requirements – Page 21 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]<strong>of</strong> the Treasury under Section 12 <strong>of</strong> the Contract Disputes Act <strong>of</strong> 1978, as amended (41 USC§ 611), that is in effect on the day after the due date. The interest penalty shall accrue dailyon the amount <strong>of</strong> the credit and shall be compounded in 30-day increments inclusive from thefirst day after the due date through the payment date. The Government shall have the right topursue the outstanding balance <strong>of</strong> any tax credit using all such collection methods as areavailable to the United States to collect debts. Such collection rights shall survive theexpiration <strong>of</strong> this Lease.In order to obtain a Tax Adjustment, the Lessor shall furnish the Contracting <strong>Office</strong>r withcopies <strong>of</strong> all paid tax receipts, or other similar evidence <strong>of</strong> payment acceptable to theContracting <strong>Office</strong>r, and a proper invoice (as described in GSA Form 3517, General Clauses,552.232-75, Prompt Payment) for the requested Tax Adjustment, including the calculationthere<strong>of</strong>. All such documents must be received by the Contracting <strong>Office</strong>r within 60 calendardays after the last date the Real Estate Tax payment is due from the Lessor to the TaxingAuthority without payment <strong>of</strong> penalty or interest. FAILURE TO SUBMIT THE PROPERINVOICE AND EVIDENCE OF PAYMENT WITHIN SUCH TIME FRAME SHALLCONSTITUTE A WAIVER OF THE LESSOR’S RIGHT TO RECEIVE A TAX ADJUSTMENTPURSUANT TO THIS CLAUSE FOR THE TAX YEAR AFFECTED.3.5.4 TAX APPEALSIf the Government occupies more than 50% <strong>of</strong> the Building by virtue <strong>of</strong> this and any otherGovernment lease(s), the Government may, upon reasonable notice, direct the Lessor toinitiate a tax appeal, or the Government may elect to contest the assessed valuation on itsown behalf or jointly on behalf <strong>of</strong> Government and the Lessor. If the Government elects tocontest the assessed valuation on its own behalf or on behalf <strong>of</strong> the Government and theLessor, the Lessor shall cooperate fully with this effort, including, without limitation, furnishingto the Government information necessary to contest the assessed valuation in accordancewith the filing requirements <strong>of</strong> the Taxing Authority, executing documents, providingdocumentary and testimonial evidence, and verifying the accuracy and completeness <strong>of</strong>records. If the Lessor initiates an appeal at the direction <strong>of</strong> the Government, the Governmentshall have the right to approve the selection <strong>of</strong> counsel who shall represent the Lessor withregard to such appeal, which approval shall not be unreasonably withheld, conditioned ordelayed, and the Lessor shall be entitled to a credit in the amount <strong>of</strong> its reasonable expensesin pursuing the appeal.3.6 INSURANCE ADJUSTMENTSThe Government shall 1) make a single annual lump sum payment to the Lessor for its sharebased on the percentage <strong>of</strong> occupancy <strong>of</strong> any increase in hazard and liability insurancepremiums during the lease term over the amount established as the base year premium, or 2)receive a lump sum payment for its share <strong>of</strong> any annual decreases for the duration <strong>of</strong> thelease in the insurance premium established as the base year premium.The amount <strong>of</strong> lump sum payment shall be based upon evidence <strong>of</strong> insurance policy andpayment submitted by the Lessor to the Contracting <strong>Office</strong>r. The Government shall beresponsible for payment <strong>of</strong> any insurance premium increase over the base year only if theproper invoice and evidence <strong>of</strong> payment is submitted by the Lessor within 90 calendar daysafter the date the insurance premium is due from the Lessor to the insurance company. Baseyear insurance premium as referred to in this paragraph is the insurance premium for the first12-month period coincident with Government occupancy <strong>of</strong> leased space in its entirety.Part I: Basic Solicitation Requirements – Page 22 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]The Government will not pay for any portion <strong>of</strong> "terrorism insurance" (Terrorism Risk InsuranceAct <strong>of</strong> 2002) obtained by the Lessor.3.7 OPERATING COSTSBeginning with the second year <strong>of</strong> the lease and each year thereafter, the Government shallpay adjusted rent for changes in costs for cleaning services, supplies, materials, trashremoval, landscaping, water, sewer charges, heating, electricity, and certain administrativeexpenses attributable to occupancy. Applicable costs listed on GSA Form 1217, Lessor'sAnnual Cost Statement, when negotiated and agreed upon, will be used to determine the baserate for operating costs adjustment.The amount <strong>of</strong> adjustment will be determined by multiplying the base rate by the annualpercent <strong>of</strong> change in the Cost <strong>of</strong> Living Index. The percent change will be computed bycomparing the index figure published for the month prior to the lease commencement datewith the index figure published for the month prior which begins each successive 12-monthperiod. For example, a lease which commences in June 2005 would use the index publishedfor May 2005, and that figure would be compared with the index published for May 2006,May 2007, and so on, to determine the percent change. The Cost <strong>of</strong> Living Index will bemeasured by the Department <strong>of</strong> Labor revised Consumer Price Index for urban wage earnersand clerical workers, U.S. city average, all items figure, (1982 to 1984 = 100) published by theBureau <strong>of</strong> Labor Statistics. Payment will be made with the monthly installment <strong>of</strong> fixed rent.Rental adjustments will be effective on the anniversary date <strong>of</strong> the lease; however, payment <strong>of</strong>the adjusted rental rate will become due on the first workday <strong>of</strong> the second month following thepublication <strong>of</strong> the Cost <strong>of</strong> Living Index for the month prior to the commencement <strong>of</strong> each12-month period.If the Government exercises an option to extend the lease term at the same rate as that <strong>of</strong> theoriginal term, the option price will be based on the adjustment during the original term. Annualadjustments will continue.In the event <strong>of</strong> any decreases in the Cost <strong>of</strong> Living Index occurring during the term <strong>of</strong> theoccupancy under the lease, the rental amount will be reduced accordingly. The amount <strong>of</strong>such reductions will be determined in the same manner as increases in rent provided underthis paragraph.The <strong>of</strong>fer shall clearly state whether the rental is firm throughout the term <strong>of</strong> the lease or if it issubject to annual adjustment <strong>of</strong> operating costs as indicated above. If operating costs will besubject to adjustment, those costs shall be specified on GSA Form 1364A, Proposal to LeaseSpace, contained elsewhere in this <strong>SFO</strong>.The base for the operating cost adjustments will be established during negotiationsbased upon the Offeror’s Final Cost Proposal, Line 27, <strong>of</strong> GSA Form 1217, Lessor’sAnnual Cost Statement.Part I: Basic Solicitation Requirements – Page 23 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]3.8 CONTRACT CHANGESAt any time, the Contracting <strong>Office</strong>r may make changes within the scope <strong>of</strong> the lease by awritten order pursuant to the Changes Clause set forth in Paragraph 33 <strong>of</strong> GSA Form 3517B,attached hereto and made a part here<strong>of</strong>, and provisions as set forth below. Changes in thedesign or the work initiated by the Lessor or the Lessor’s Design Team or Contractor do notconstitute a change for cost. Any such changes must be approved by the Contracting <strong>Office</strong>r.See design and construction documents afterward.The clauses entitled "Changes" in FAR 52.243-4 and "Differing Site Conditions" in FAR52.236-2 will be supplemented with the following two clauses. The clause in Paragraph 3.8.1below will apply to negotiated changes exceeding $500,000 and does not provide ceiling ratesfor indirect expenses. Such expenses will be included as part <strong>of</strong> the submission <strong>of</strong> certifiedcost and pricing data, and will be negotiated by the Contracting <strong>Office</strong>r and audited inaccordance with Department <strong>of</strong> Veterans Affairs Acquisition Regulation (VAAR) 815.805-5. (Acopy <strong>of</strong> this provision is available upon request.) When the negotiated change will be lessthan $500,000, the clause specified in Paragraph 3.8.2 below will apply. Certificates <strong>of</strong> currentcost and pricing data shall accompany proposals over $100,000 and not exceeding $500,000.If cost and pricing data are required by FAR for proposals <strong>of</strong> $100,000 or less, the Contracting<strong>Office</strong>r may require that it be certified in accordance with FAR 15.403-4(a)(2). It must beemphasized that the indirect cost rates are ceiling rates only, and the Contracting <strong>Office</strong>r willnegotiate the indirect expense rates within the ceiling limitations. The clauses are a result <strong>of</strong>an approved FAR deviation pursuant to Subpart 801.4.3.8.1 APPLICABLE TO CHANGES COSTING OVER $500,000A. Proposals for ChangesWhen requested by the Contracting <strong>Office</strong>r, the contractor shall submit proposals for changesin work to the Contracting <strong>Office</strong>r or the Contracting <strong>Office</strong>r’s designee. Proposals, to besubmitted within 30 calendar days after receipt <strong>of</strong> request, shall be in legible form, original andtwo copies. The contractor shall provide cost or pricing data in accordance with theinstructions in Table 15-2 <strong>of</strong> FAR 15-403-5 in the format indicated for "Modifications" //or otherformat acceptable to the Contracting <strong>Office</strong>r//. Proposals shall consist <strong>of</strong> an itemizedbreakdown that includes material quantities, unit prices, labor costs (separated into trades),construction equipment, etc. (Labor costs are to be identified with specific material placed oroperation performed.) The contractor shall execute a Certificate <strong>of</strong> Current Cost or PricingData in accordance with FAR 15-406-2. The contractor must obtain and furnish with eachproposal an itemized breakdown and certificate as described above, signed by eachsubcontractor participating in the change regardless to tier.B. Tentative PricingWhen the necessity to proceed with a change does not allow sufficient time to negotiate amodification, or because <strong>of</strong> failure to reach an agreement, the Contracting <strong>Office</strong>r may issue achange order instructing the contractor to proceed on the basis <strong>of</strong> a tentative price based onthe best estimate available at the time, with the firm price to be determined later. Furthermore,when the change order is issued, the contractor shall submit a proposal for cost <strong>of</strong> changes inwork within 30 calendar days.C. Settlement By DeterminationThe Contracting <strong>Office</strong>r will consider issuing a settlement by determination to the contract, ifthe contractor’s proposal required by Paragraphs 3.8.1A and 3.8.1B <strong>of</strong> this clause is notreceived within 30 calendar days or if agreement has not been reached.Part I: Basic Solicitation Requirements – Page 24 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]3.8.2 APPLICABLE TO CHANGES COSTING $500,000 OR LESSA. Proposals for ChangesWhen requested by the Contracting <strong>Office</strong>r, the contractor shall submit proposals for changesin work to the Contracting <strong>Office</strong>r or designee. Proposals, to be submitted within 30 calendardays after receipt <strong>of</strong> request, shall be in legible form, original and two copies, with an itemizedbreakdown that will include material, quantities, unit prices, labor costs (separated into trades),construction equipment, etc. (Labor costs are to be identified with specific material placed oroperation performed.) The contractor must obtain and furnish with a proposal an itemizedbreakdown as described above, signed by each subcontractor participating in the change,regardless <strong>of</strong> tier. When requested by the Contracting <strong>Office</strong>r, the contractor and eachsubcontractor participating in the change, regardless <strong>of</strong> tier, shall execute a Certificate <strong>of</strong>Current Cost or Pricing Data in accordance with FAR 15-406-2. For proposals over $100,000,the cost or pricing data shall be submitted in accordance with the instructions in Table 15-2 <strong>of</strong>FAR 15-403-5 in the format indicated for "Modifications" //or other format acceptable to theContracting <strong>Office</strong>r//. No itemized breakdown will be required for proposals amounting to lessthan $1,000.B. Tentative PricingWhen the necessity to proceed with a change does not allow sufficient time to negotiate amodification or if there is a failure to reach an agreement, the Contracting <strong>Office</strong>r may issue achange order instructing the contractor to proceed on the basis <strong>of</strong> a tentative price based onthe best estimate available at the time, with the firm price to be determined later. Furthermore,when the change order is issued, the contractor shall submit a proposal for cost <strong>of</strong> changes inwork within 30 calendar days.C. Settlement By DeterminationThe Contracting <strong>Office</strong>r will consider issuing a settlement by determination to the contract, ifthe contractor’s proposal required by paragraphs (a) and (b) <strong>of</strong> this clause is not receivedwithin 30 calendar days, or if agreement has not been reached.D. Allowances for Overhead and Pr<strong>of</strong>itAllowances not to exceed 10% each for overhead and pr<strong>of</strong>it for the party performing the workwill be based on the value <strong>of</strong> labor, material, and use <strong>of</strong> construction equipment required toaccomplish the change. As the value <strong>of</strong> the change increases, a declining scale will be usedin negotiating the percentage <strong>of</strong> overhead and pr<strong>of</strong>it. Allowable percentages on changes willnot exceed the following: 10% overhead and 10% pr<strong>of</strong>it on the first $20,000 7-1/2% overhead and 7-1/2% pr<strong>of</strong>it on the next $30,000 5% overhead and 5% pr<strong>of</strong>it on balance over $50,000Pr<strong>of</strong>it shall be computed by multiplying the pr<strong>of</strong>it percentage by the sum <strong>of</strong> the direct costs andcomputed overhead costs.E. Allowable Fee On ChangesThe prime contractor’s or upper-tier subcontractor’s fee on work performed by lower-tiersubcontractors will be based on the net increased cost to the prime contractor or upper-tiersubcontractor, as applicable. Allowable fee on changes will not exceed the following:Part I: Basic Solicitation Requirements – Page 25 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY] 10% fee on the first $20,000 7-1/2% fee on the next $30,000 5% fee on balance over $50,000F. Multiple TiersNot more than four percentages, none <strong>of</strong> which exceed the percentages shown above, will beallowed regardless <strong>of</strong> the number <strong>of</strong> tiers <strong>of</strong> subcontractors.G. Credit ItemsWhere the contractor’s or subcontractor’s portion <strong>of</strong> change involves credit terms, such itemsmust be deducted prior to adding overhead and pr<strong>of</strong>it for the party performing the work. Thecontractor’s fee is limited to the net increase to contractor <strong>of</strong> subcontractors’ portions <strong>of</strong> costcomputed in accordance herewith.Where a change involves credit items only, a proper measure <strong>of</strong> the amount <strong>of</strong> downwardadjustment in the contract price is the reasonable cost to the contractor if he/she performedthe deleted work. A reasonable allowance for overhead and pr<strong>of</strong>it are properly includable aspart <strong>of</strong> the downward adjustment for a deductive change. The amount <strong>of</strong> such allowance issubject to negotiation.H. Tax and InsuranceCost <strong>of</strong> Federal Old Age Benefit (Social Security) tax and <strong>of</strong> Workmen’s Compensation andPublic Liability insurance appertaining to change are allowable. While no percentage will beallowed thereon for overhead or pr<strong>of</strong>it, prime contractor’s fee will be allowed on such items insubcontractors’ proposals.I. Items Included In Overhead and FeeOverhead and contractors fee percentages shall be considered to include insurance, otherthan mentioned herein; field and <strong>of</strong>fice supervisors and assistants; security police; use <strong>of</strong> smalltools, incidental job burdens, and general home <strong>of</strong>fice expenses; and no separate allowancewill be made therefore. Assistants to <strong>of</strong>fice supervisors include all clerical, stenographic, andgeneral <strong>of</strong>fice help. Incidental job burdens include, but are not necessarily limited to, <strong>of</strong>ficeequipment and supplies, temporary toilets, telephone, and conformance to OSHArequirements. Items such as, but not necessarily limited to, review and coordination,estimating, and expediting relative to contract changes, are associated with field and <strong>of</strong>ficesupervision and are considered to be included in the contractor’s overhead and/or feepercentage.J. Bond Premium AdjustmentBond premium adjustment, consequent upon changes ordered, will be made as elsewherespecified at the time <strong>of</strong> final settlement under the contract and will not be included in theindividual change.K. Implementation <strong>of</strong> ChangesUpon receipt <strong>of</strong> a written order from the Contracting <strong>Office</strong>r for a change(s), the Lessor shallimmediately begin to implement such a change(s). Any dispute involving entitlement toadditional compensation or additional time for the work performed will be resolved pursuant tothe terms <strong>of</strong> the Disputes Clause, if not otherwise resolved by the parties. However, nothing inthat clause shall excuse the Lessor from proceeding with the contract as changed.Part I: Basic Solicitation Requirements – Page 26 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Lump sum payment for changes shall be made upon completion, acceptance, and beneficialoccupancy <strong>of</strong> the building.3.9 WAIVER OF CLAIMS FOR WASTE OR DAMAGESThe Lessor will be required to waive the right to claim for waste or damages arising from themaking or removing <strong>of</strong> alterations or special work (Paragraph 3.4).The Lessor will be required to waive the right to claim for delay, waste, or damages arisingfrom the acts, errors, or omissions <strong>of</strong> Lessor or the Lessor’s Design Team or Contractor.All property placed in, upon, or attached to the premises to be leased that is provided by theGovernment or for which the Government pays by means <strong>of</strong> lump-sum (Schedule B items),shall be and remain the property <strong>of</strong> the Government, and may be removed or otherwisedisposed <strong>of</strong> by the Government at its sole discretion. The Lessor will be required to waive theright to claims arising from the removal or disposal <strong>of</strong> any Government property that remainsin, upon, or attached to the premises at the termination <strong>of</strong> the lease.3.10 LIQUIDATED DAMAGESIn case <strong>of</strong> failure on the part <strong>of</strong> the Lessor to complete the work within the time fixed in thelease contract or letter <strong>of</strong> award, the Lessor shall pay the Government as fixed and agreedliquidated damages, pursuant to this clause, the sum <strong>of</strong> // One Thousand Five HundredDollars ($1,500.00) // // [ insert amount <strong>of</strong> liquidated damages in words (and numerals)] // foreach and every calendar day that the delivery is delayed beyond the date specified for delivery<strong>of</strong> all the space ready for acceptance and beneficial occupancy by the Government.3.11 RECORDATION REQUIREMENTSThe Lessor will be required to execute all documents necessary to record the lease in thecounty or political subdivision in which the building is located. The recordation and allexpenses associated with this action are the responsibility <strong>of</strong> the Lessor. This action must beaccomplished within 30 calendar days after award. Evidence <strong>of</strong> such must be provided to theContracting <strong>Office</strong>r.3.12 ADJUSTMENT FOR VACATED PREMISESIf the Government fails to occupy any portion <strong>of</strong> the leased premises or vacates the premisesin whole or in part prior to expiration <strong>of</strong> the firm term <strong>of</strong> the lease, the rental rate shall bereduced as follows: the rate shall be reduced by that portion <strong>of</strong> the cost per square foot <strong>of</strong>operating expenses not required to maintain the space. Said reduction shall occur after theGovernment gives 30 days prior notice to the Lessor, and shall continue in effect until theGovernment occupies the premises or the lease expires or is terminated.Part I: Basic Solicitation Requirements – Page 27 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]3.13 RELOCATION ASSISTANCE ACTIf an improved site is <strong>of</strong>fered and new construction will result in the displacement <strong>of</strong> individualsor businesses, the successful Offeror shall be responsible for payment <strong>of</strong> relocation costs fordisplaced persons in accordance with the Uniform Relocation Assistance and Real PropertyAcquisition Policies Act <strong>of</strong> 1970 as amended and 49 CFR Part 24.3.14 RENTABLE AND NET USABLE SQUARE FEET3.14.1 RENTABLE SPACERentable Space is determined by the building owner and may vary by city or by building withinthe same city. The rentable space may include a share <strong>of</strong> building support/common areassuch as elevator lobbies, building corridors, and floor service areas. Floor service areastypically include restrooms, janitor rooms, telecommunications rooms, electrical closets, andmechanical rooms. The rentable space does not include vertical building penetrations andtheir enclosing walls, such as stairs, elevator shafts, and vertical ducts.3.14.2 NET USABLE SPACENet usable space is that portion <strong>of</strong> rentable space that is available for a tenant’s personnel,furnishings, and equipment. Net usable space is the area for which VA will pay a square footrate. It is determined as follows:If the space is on a single tenancy floor, compute the inside gross area by measuringbetween the inside finish <strong>of</strong> the permanent exterior building walls or from the face <strong>of</strong>the convectors (pipes or other wall-hung fixtures) if the convector occupies at least50% <strong>of</strong> the length <strong>of</strong> exterior walls.If the space is on a multiple tenancy floor, measure from the exterior building walls asabove and to the room side finish <strong>of</strong> the fixed corridor and shaft walls and/or thecenter <strong>of</strong> tenant-separating partitions.In all measurements, make no deductions for columns and projections enclosing the structuralelements <strong>of</strong> the building. Deduct the following from the inside gross area, including theenclosing walls, to arrive at the figure for net usable square feet:Those housekeeping closets not contained in programmed areas. See Paragraph4.2.3A.Public restrooms and lounges. See Paragraph 4.2.3B.Building equipment and service areas. See Paragraph 4.2.3C.Public corridors and entrance lobbies. See Paragraph 4.2.3D.Vertical circulation. See Paragraph 4.2.3E.Shafts and risers. See Paragraph 4.2.3F.Offerors shall indicate on GSA Form 1364A, Proposal to Lease Space, Section II (SpaceOffered and Rates, the amount <strong>of</strong> rentable space <strong>of</strong>fered (8a.(2)) and the cost per rentablesquare footage (8a.(4))).Part I: Basic Solicitation Requirements – Page 28 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]3.15 APPURTENANT AREASThe right to use appurtenant areas and facilities is included. The Government reserves theright to post Government rules and regulations where the Government leases space.3.16 VENDING FACILITIESVA is required to comply with the provisions <strong>of</strong> the Randolph-Sheppard Act pertaining toVending Facility Programs for the Blind, 34 CFR 395, on properties owned, leased, oroccupied by the Government. VA will have notified the appropriate State licensing agency <strong>of</strong>intent to occupy space under this lease. The State licensing agency shall be afforded theopportunity to determine whether the building includes a satisfactory site for a vending facilityand, subject to the approval by VA, shall be <strong>of</strong>fered the opportunity to select the location andtype <strong>of</strong> vending facility to be operated by a blind vendor prior to the completion <strong>of</strong> the finalspace layout.The Lessor will have no right to control or receive income from automatic vending machineslocated in the vending facility <strong>of</strong> the leased premises. // If space is <strong>of</strong>fered in existing buildingswith vending facilities established under pre-existing agreements, VA will ensure that thefacility does not compete with other facilities having exclusive rights in the building. Offerorsmust advise VA if such rights exist.//3.17 DESIGN AND CONSTRUCTION DOCUMENTS AFTER AWARDDesign development after award shall be in accordance with the requirements <strong>of</strong> thisSolicitation, and shall be a direct extension <strong>of</strong> the submitted design concept. The designdevelopment shall retain all the functional and basic physical characteristics <strong>of</strong> that concept.The Contracting <strong>Office</strong>r shall have the right to reject any aspect <strong>of</strong> subsequent design thatvaries from the concept and would adversely affect the Government's use and occupancy <strong>of</strong>the space or the Government's other interests in the building as set forth or implied in thisSolicitation. Nonetheless, the Offeror may propose for the Contracting <strong>Office</strong>r's acceptance,or the Contracting <strong>Office</strong>r may propose for the Offeror's acceptance, evolutionary adaptationsor changes to the concept, that improve the design. Neither party will unreasonably withholdsuch acceptance <strong>of</strong> demonstrated beneficial design adaptations <strong>of</strong> the concept which wouldnot measurably increase the costs <strong>of</strong> construction, operation, or occupancy <strong>of</strong> the space orbuilding and which would not decrease the utility <strong>of</strong> the space or building to either party.Changes to planned design layout do not constitute a change for cost.3.17.1 RESPONSIBILITIES OF LESSOR’S DESIGN TEAMThe Lessor’s design team (A/E) shall be responsible for producing a complete set <strong>of</strong> drawings,design narrative/analysis, calculations, sample boards, and specifications in accordance withpr<strong>of</strong>essional standard practices and the criteria contained in this <strong>SFO</strong>. Drawings and relateddata shall be prepared in accordance with the National CAD Standard (NCS) published by theNational Institute <strong>of</strong> Building Sciences (NIBS) as amended by the VHA National CAD StandardApplication Guide with regard to conventions in layer names, drawing organization, andplotting. Each A/E discipline shall receive a copy <strong>of</strong> VHA National CAD Standard ApplicationGuide. The Lessor and Lessor’s A/E are responsible for obtaining the NCS(http://www.cfm.va.gov/til/projReq.asp#cad).Part I: Basic Solicitation Requirements – Page 29 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]The Lessor’s A/E shall develop and execute a Quality Assurance/Quality Control (QA/QC)program; and shall demonstrate that the project plans and specifications have gone through arigorous review and coordination effort with each required submittal. The Lessor’s A/E shallconduct coordination meetings between A/E technical disciplines before submitting materialfor each VA review and provide minutes <strong>of</strong> the meetings to VA.3.17.2 INDEPENDENT TECHNICAL REVIEWThe Lessor shall be responsible for paying for three independent technical and life safetyreviews at the Second Design Development submittal, at the 75% <strong>Construction</strong> Documentsubmission, and independent back check <strong>of</strong> the Final (100%) <strong>Construction</strong> Documents. Thereviews shall encompass all disciplines. The reviews shall be accomplished by independentpr<strong>of</strong>essional entities selected by VA that are registered in the appropriate fields <strong>of</strong> expertise.NOTE: The Lessor shall allow approximately 15 working days for review and comment by theGovernment at each review stage.The independent reviews are limited to checking for general compliance with the <strong>SFO</strong> and VArequirements. The independent reviews do not take the place <strong>of</strong> the Lessor’s QA/QCprogram, nor the code review by the Authority Having Jurisdiction (AHJ). The Lessor shallhave the responsibility <strong>of</strong> ensuring that the documents go through the review and permittingprocess <strong>of</strong> the local AHJ. If the independent technical review conflicts with the review by theAHJ, the more stringent requirement shall apply. If there is any question as to whichrequirement shall apply, the Lessor shall request a determination from the Contracting <strong>Office</strong>r.For purposes <strong>of</strong> this Solicitation For Offers (<strong>SFO</strong>), the firm <strong>of</strong> [insert IDIQ or other A/E firmname here] is the authorized representative <strong>of</strong> the Department <strong>of</strong> Veterans Affairs (VA) andshall provide technical review services to VA in connection with this Lease. It is understoodbetween the Lessor and VA that [insert IDIQ or other A/E firm name here] shall provideindependent technical services on behalf <strong>of</strong> VA to assist in reviewing drawings.In connection with the provisions <strong>of</strong> such independent technical services, the Lessor shallprovide in the base rental rate a sum <strong>of</strong> [insert amount in words and figures here] to be paid to[insert IDIQ or other A/E firm name here]. Such fee shall be due and payable, as follows:Approximately forty (40)% <strong>of</strong> the fee shall be paid to [insert IDIQ or other A/E firm name here]within thirty (30) calendar days following receipt by the Lessor <strong>of</strong> an invoice certified andapproved by VA; following review <strong>of</strong> the Second Design Development package, and:Approximately fifty (50)% <strong>of</strong> the fee shall be paid to [insert IDIQ or other A/E firm name here]within thirty (30) calendar days following receipt by the Lessor <strong>of</strong> a invoice certified andapproved by VA; following review <strong>of</strong> the 75% <strong>Construction</strong> Document package.The balance <strong>of</strong> the fee shall be paid to [insert IDIQ or other A/E firm name here] within thirty(30) calendar days following receipt by the Lessor <strong>of</strong> a final invoice certified and approved byVA, following back check <strong>of</strong> the final <strong>Construction</strong> Document package.The Lessor’s responsibilities to pay the fee(s) to [insert IDIQ or other A/E firm name here] isindependent <strong>of</strong> any other Lessor financial responsibilities <strong>of</strong> this Lease and shall not be usedto negotiate or <strong>of</strong>fset any credits owed VA by the Lessor. However, in the event Lessor shallfail to pay the fee(s) owed to [insert IDIQ or other A/E firm name here] pursuant to thecompensation schedule outlined herein, VA, at VA’s sole option, shall pay the fee owed onPart I: Basic Solicitation Requirements – Page 30 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]behalf <strong>of</strong> Lessor to [insert IDIQ or other A/E firm name here] out <strong>of</strong> rent payments and/or anylump-sum payments owed or to-be-owed to Lessor for reimbursement(s) for services/workprovided by the Lessor.3.18 DESIGN DEVELOPMENTThe Design Development phase involves the production <strong>of</strong> drawings, specifications,calculations, narratives, reports, and other materials as listed in Paragraph "SUBMITTALREQUIREMENTS FOR DD AND CD REVIEWS." Two Design Development submissions shallbe required for review by the government. The submittals shall fully describe the architecturaland engineering design approach used, and the systems, materials, and layout for the site andbuilding. The submittals shall be reviewed by VA and the independent technical reviewers todetermine that the design proposed by the Lessor conforms to the space / functional andtechnical requirements <strong>of</strong> this <strong>SFO</strong>.Utilizing the conceptual layout diagram provided by VA at time <strong>of</strong> award and working inconjunction with the Contracting <strong>Office</strong>r or designee, the Lessor shall produce the First DesignDevelopment Submittal within 45 calendar days <strong>of</strong> award.After VA review and comment on the First Design Development Submittal, the Lessor shallcomplete and submit the Second Design Development Submittal within 30 calendar days:3.19 CONSTRUCTION DOCUMENTSThe <strong>Construction</strong> Document phase involves the production <strong>of</strong> complete drawings,specifications, and other documents necessary for the bidding and construction <strong>of</strong> the project.<strong>Construction</strong> documents shall be prepared from the approved design developmentdocuments. It is the Lessor’s responsibility to provide a quality set <strong>of</strong> documents. Documentsshall be complete and fully coordinated. Prior to reproduction for issue for construction bids,make any changes to the documents identified as necessary by the Contracting <strong>Office</strong>r duringreviews. 100% <strong>Construction</strong> Documents shall contain the seal (or stamp) <strong>of</strong> a pr<strong>of</strong>essionalengineer or architect, registered in the discipline represented by the drawing. Finalcalculations shall contain the seal (or stamp) <strong>of</strong> a registered pr<strong>of</strong>essional engineer. Personssealing the construction documents or calculations shall be the entities identified by the Lessorunder Paragraph Design Team Qualifications above. Two construction document periodsubmissions shall be required: the first at 75% complete and the second at 100% complete.Within 45 calendar days <strong>of</strong> receipt <strong>of</strong> written VA approval <strong>of</strong> the Second Design DevelopmentSubmittal, the Lessor shall produce a complete set <strong>of</strong> 75% construction documents andspecifications for review.Within 30 calendar days <strong>of</strong> receiving written notification <strong>of</strong> VA’s 75% construction documentreview comments, the Lessor shall submit a complete set <strong>of</strong> 100% working drawings andspecifications for review. The Lessor shall incorporate all VA comments <strong>of</strong> the 75% contractdocument submittal.NOTE: The Lessor shall allow approximately 15 working days from date <strong>of</strong> receipt forreview and comment by the Government at each review stage.Part I: Basic Solicitation Requirements – Page 31 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]3.20 SUBMITTAL REQUIREMENTS FOR DD AND CD REVIEWS3.20.1 GENERAL REQUIREMENTSProvide a design narrative/analysis for each technical discipline (e.g., architectural,mechanical, fire protection, etc.) which describes the intent <strong>of</strong> each discipline with each designdevelopment submission.Provide computations and sizing calculations for electrical, mechanical (HVAC, plumbing, andsteam), sanitary, structural, and fire protection designs. For computerized calculations, submitcomplete and clear documentation <strong>of</strong> computer programs, interpretation <strong>of</strong> input/output, anddescription <strong>of</strong> program procedures.Provide individually packaged drawings for each submission to each unit specified inParagraph "Distribution <strong>of</strong> A/E Materials."At each submission, the A/E shall date and appropriately label all materials. In eachsubmission, the A/E shall incorporate the corrections, adjustments, and changes made by VAat the previous review.A. Format(1) DrawingsHard copies shall be black line prints on bond paper, full size (30” x 42”) and half size(15” x 21”). Each set shall contain all sheets for all disciplines (partial sets are not allowed).Electronic submissions may be plots or scans in Adobe® PDF format; except floor (spacelayout) plans shall be provided in both PDF format and as AutoCAD® release [____] drawingfiles to facilitate verification <strong>of</strong> net and rentable areas. Quantities shall be as indicated below.(2) SpecificationsHard copies shall be printed double-sided on 8½" x 11" bond paper. Electronic submissionsmay be in Micros<strong>of</strong>t® Word® 2003 or Adobe® PDF format. Electronic files containing two ormore specification sections shall be indexed or bookmarked.(3) NarrativesHard copies shall be printed on 8½" x 11" bond paper. Electronic submissions may be inMicros<strong>of</strong>t® Word® 2003 or Adobe® PDF format. Bookmark or index all electronic files.(4) CalculationsHard copies shall be printed on 8½" x 11" bond paper. Electronic submissions may beAdobe® PDF format. Bookmark or index all electronic files.B. Distribution <strong>of</strong> A/E MaterialsElectronic materials shall be submitted on CD-ROM or DVD. Each set <strong>of</strong> paper (hard) copiesshall be bound or may be assembled in three-ring binders. Label each disk and paper set toindentify the project, location, contract number, and submittal type and date. Requirednumber <strong>of</strong> copies is designated in the following table.Part I: Basic Solicitation Requirements – Page 32 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Submittal Medical Center ResidentEngineerFirst Design DevelopmentNarratives 1 each hard andelectronicDrawings1 each hard andelectronicSpecifications 1 each hard andelectronicCalculations 1 each hard andelectronicSecond Design DevelopmentNarratives 1 each hard andelectronicDrawings1 each hard andelectronicSpecifications 1 each hard andelectronicCalculations 1 each hard andelectronic75% <strong>Construction</strong> DocumentsDrawings1 each hard andelectronicSpecifications 1 each hard andelectronicCalculations 1 each hard andelectronic100% <strong>Construction</strong> DocumentsDrawings1 each hard andelectronicSpecifications 1 each hard andelectronicCalculations 1 each hard andelectronic1 each hard andelectronic1 each hard andelectronic1 each hard andelectronic1 each hard andelectronic1 each hard andelectronic1 each hard andelectronic1 each hard andelectronic1 each hard andelectronic1 each hard andelectronic1 each hard andelectronic1 each hard andelectronic1 each hard andelectronic1 each hard andelectronic1 each hard andelectronicInd TechReviewer6 hard copies6 hard copies6 hard copies1 hard copy eachdiscipline6 hard copies6 hard copies6 hard copies1 hard copy eachdiscipline6 hard copies6 hard copies1 hard copy eachdiscipline6 hard copies6 hard copies1 hard copy eachdiscipline3.20.2 FIRST DESIGN DEVELOPMENT SUBMITTALA. SiteSubmit preliminary drawings showing the development concept.topographic, utility, and landscape surveys.Submit copies <strong>of</strong>Include layout plan(s) showing location <strong>of</strong>: building and structures, roads, fire access, parking,mechanical, electrical, and telecommunications equipment on grade, service area(s),entrances and exits, and walks; Grading plan, showing existing and proposed contours; andPlanting plan, showing plant groupings.Submit preliminary narrative for site design concept with analysis <strong>of</strong> site, circulation study,phasing analysis, and parking analysis.Part I: Basic Solicitation Requirements – Page 33 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]B. StructuralSubmit preliminary structural plans and sections. Show bay sizes, locations and sizes <strong>of</strong>columns, bearing walls, and foundations. Show locations and depths <strong>of</strong> //floor and// ro<strong>of</strong>framing members. Show locations and sizes <strong>of</strong> lateral force resisting elements. Indicatelocations <strong>of</strong> major mechanical, electrical, and other special equipment items.Submit preliminary design narrative, including basis for selection <strong>of</strong> proposed structuralsystem, and preliminary supporting calculations.C. ArchitecturalSubmit final layout drawings (floor plans) for all floors at 1/8-inch scale. Drawings shall be <strong>of</strong>sufficient precision and/or adequately dimensioned so that the Government may accuratelycompute rentable and useable areas to verify compliance with solicitation requirements.Submit preliminary equipment plans (at ¼-inch scale) and preliminary equipment schedulesthat reflect the requirements in this Basic Solicitation as well as Schedule B "SpecialEquipment Requirements." Identify all equipment for each clinical or laboratory room listed inSchedule B. Equipment plans are not required for <strong>of</strong>fices, consultation rooms, classrooms,conference rooms, and waiting rooms.Submit building elevations, showing all significant materials, including their colors, ro<strong>of</strong> topmechanical equipment, and any architectural screens. Elevations shall show massing,proposed fenestration, and the building's relationship to adjacent structures and the finishgrade.// If building is designed for future expansion, delineate elevations with and without thefuture expansion.//D. Interior DesignNo requirements at this submittal.E. Sustainable Design & Energy EfficiencySubmit preliminary LEED® Silver Equivalency checklist. Submit preliminary narrativeaddressing how the design will meet Federal Mandates for sustainability and energyefficiency, including site base conditions analysis, preliminary base case energy and wateranalysis, and integrated strategies.F. Fire Protection/Life SafetySubmit preliminary design narrative. The fire protection narrative shall discuss: fire and smokeseparations, fire sprinkler/standpipe system, size <strong>of</strong> fire pumps, water supply available/max.demand, water flow testing results, fire alarm systems, kitchen extinguishing systems, size <strong>of</strong>air handling units, exit paths from each zone, distances to stairs, occupancy <strong>of</strong> each area, exitcalculations for each floor, and smoke control features.Submit preliminary fire protection plans plans/drawings (minimum 1/8-inch scale) illustrating:sprinkler zones, fire alarm zones, smoke zones, building water supply, interior sprinkler supplyrisers, standpipes, fire extinguisher cabinets, and firepro<strong>of</strong>ing <strong>of</strong> structural members.G. MechanicalSubmit preliminary design narrative addressing description <strong>of</strong> HVAC systems, equipment foreach functional space, and life-cycle cost analysis. Submit preliminary engineeringcalculations. Provide specific design recommendations and full back-up data. Include theheating and cooling capacities <strong>of</strong> each functional area and the block cooling and heating loadsfor the building.Part I: Basic Solicitation Requirements – Page 34 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Submit preliminary drawings (minimum 1/8-inch scale) indicating: tentative location/sizes formechanical equipment room(s), principal vertical shafts, and block layout <strong>of</strong> equipment.Indicate preliminary sizes and locations <strong>of</strong> louvers required for outside, exhaust, and relief air.H. PlumbingSubmit preliminary design narrative addressing plumbing systems including supply, waste,and medical or laboratory gas systems.Submit preliminary drawings (minimum 1/8-inch scale) including: room names and numbers,plumbing fixtures w/VA numbering system, equipment, medical gas outlets, laboratory gasoutlets, and routing for plumbing piping.I. ElectricalSubmit preliminary design narrative for electrical systems and preliminary load calculations fornormal and emergency power. Include basic assumptions, and projected load <strong>of</strong> newconstruction.Contact the electrical utility that will supply electrical power. Submit a written summary <strong>of</strong> anyconversations with the electrical utility. Submit a full set <strong>of</strong> preliminary electrical site, lighting,and power floor plans, showing equipment, lighting, and receptacle locations. Submitproposed one-line and riser diagrams <strong>of</strong> the normal electrical power distribution system andthe emergency power system. Final equipment ratings may vary, but locate all equipment andidentify and size dimensionally for adequate capacity. Provide preliminary fault current,generator sizing, load, feeder and equipment sizing, voltage drop, lightning protection riskanalysis, and lighting and energy calculations.J. Telecommunications and Special SystemsSubmit preliminary design narrative addressing Telecommunications and Special Systems.Submit preliminary Telecommunications and Special Systems drawings including site plan andfloor plans (minimum 1/8-inch scale). Show locations <strong>of</strong> and sizes <strong>of</strong> computer rooms andequipment and distribution rooms for telecommunications and special systems. Identify lowvoltageoutlet connections and major equipment items. Include basic cable tray routing.Provide legend <strong>of</strong> symbols.3.20.3 SECOND DESIGN DEVELOPMENT SUBMITTALA. SiteSubmit design narrative and calculations for site development. Include a Geotechnical Reportthat addresses at a minimum, soil bearing pressures, slab design, existing soil conditions,percolation rates, slope stability and recommended mitigation, pavement design, etc.Include a Hydrology and Hydraulic analysis and report in support <strong>of</strong> the proposed designwhich complies with local, state, and federal flood plain management standards andmethodologies. It is not acceptable to connect storm drain systems to the sanitary system.Submit completed design development drawings for all site work and utility systems. Includelayout plan(s) showing location <strong>of</strong>: building and structures, roads, fire access, parking,accessible spaces, van spaces, mechanical and electrical equipment on grade, <strong>of</strong>f-site roads,<strong>of</strong>f-site utilities, service area(s), entrances and exits, walks, inlets, vertical and horizontal roadalignment, and paving joint patterns.Part I: Basic Solicitation Requirements – Page 35 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Submit grading plan showing: existing contours, proposed contours, spot elevations atstructure corners, entrances, equipment pads, etc., first floor elevations, rim and invertelevations on storm drainage fixtures, and erosion and sediment control.Include conceptual drawings that reflect the alignment <strong>of</strong> the water distribution system,including location <strong>of</strong> fire hydrants and points <strong>of</strong> connection to the public water system.Include conceptual drawings that reflect the alignment <strong>of</strong> the sanitary sewer system, includingmanhole locations and points <strong>of</strong> connection to the downstream sewer system.Include conceptual storm drain drawings based on the Hydrology and Hydraulic report. Thedrawings should reflect the alignment <strong>of</strong> the storm sewer system, including location <strong>of</strong>detention/retention basins, junction structures, channels, pipe structures and catch basins,connections to the existing storm system (if one exists) or flow arrows indicating the direction<strong>of</strong> surface flow.Submit landscape drawings including planting plan showing: list <strong>of</strong> plant material and limits <strong>of</strong>irrigation.Submit signage plan and schedule.Submit site and landscape details.Submit completed design narrative and calculations.Submit draft specifications for earthwork, utility systems, and site improvements.B. StructuralSubmit completed design development drawings including structural plans, sections, anddetails. Show bay sizes, locations and sizes <strong>of</strong> columns, bearing walls, and foundations.Show locations and depths <strong>of</strong> //floor and// ro<strong>of</strong> framing members. Indicate floor and ro<strong>of</strong> slabthickness. Coordinate floor or ro<strong>of</strong> depressions and penetrations with architectural,mechanical, plumbing, and electrical work. Indicate major mechanical, electrical, and otherspecial equipment items; and show chases or shafts. Show framing and support required atthose locations. Show locations and sizes <strong>of</strong> lateral force resisting elements.Submit final design narrative including basis for selection <strong>of</strong> proposed structural system.Submit calculations for gravity and lateral design.Submit draft specifications for structural materials.C. ArchitecturalSubmit completed design development floor plans (minimum 1/8-inch scale) for each floorshowing all rooms, room names, room numbers, door locations and swings, smoke and firerated partitions, and fire extinguisher cabinets. Label departments or services. Show allrooms and chases for mechanical, electrical, and low-voltage (communications) equipment.Show wall thickness and chase walls. Show plumbing fixtures and equipment occupying floorspace. Indicate handrails and corner guards. Show column grid with columns indicated // andexpansion and seismic joints //.Part I: Basic Solicitation Requirements – Page 36 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Submit completed equipment plans, elevations (minimum ¼-inch scale), and schedules. Listany changes or deviations from Schedule B for review and approval by the Contracting <strong>Office</strong>ror designee.Submit completed design development ro<strong>of</strong> plan, exterior elevations, building and wallsections, and key details. Submit room finish, door, and window schedules. Submit generalnotes, symbol legends, and abbreviations.Submit final design narrative.Submit draft specification sections.D. Interior DesignSubmit interior design narrative. Discuss information gathered during interior designprogramming with the VAMC project coordinator and interior designer including, but not limitedto the following: interior and exterior design and materials, light, safety, patient pr<strong>of</strong>ile,customer’s "vision" or desired image, public vs. private spaces, signage, regional influences,etc.Present the preliminary design solution for the primary areas <strong>of</strong> the project. Use broadcategories <strong>of</strong> materials, finishes, color palettes, patterns, textures, and scales. Include primaryand secondary corridors, lobbies, waiting rooms, <strong>of</strong>fices, exam and treatment rooms, and toiletrooms. Discuss the relationship among departments and functions, and between public andprivate spaces.E. Sustainable Design & Energy EfficiencySubmit LEED® Silver Equivalency checklist. Submit narrative addressing how the design willmeet Federal Mandates for sustainability and energy efficiency. Submit refined ASHRAE90.1-2004 base-case energy model and as-designed energy model, including all assumptionsused, targeting compliance with the 30% energy reduction goal, or exceeding the goal.Submit refined water use analysis and daylighting calculations. Submit preliminarycommissioning specifications.F. Fire Protection/Life SafetySubmit completed fire protection narrative. Indicate NFPA 220 and UBC fire resistive rating <strong>of</strong>the building, NFPA 101 occupancy type, and fire protection code analysis to assesscompliance with NFPA 101. Provide information to meet JCAHO requirements, e.g., location<strong>of</strong> all fire rated barriers, smoke barriers, exit signs, fire extinguishers, manual pull stations,smoke detectors, and sprinkler flow switches.Submit completed design development fire protection plans/drawings illustrating: sprinklerzones, fire alarm zones, smoke zones, building water supply, sprinkler/standpipe riser supplypiping, termination <strong>of</strong> sprinkler main and inspector test drains, sprinkler alarm valves,waterflow and tamper switches, sprinkler system fire department connections, sprinkler designhazards per NFPA 13, exit signs and emergency lighting, fire sprinklers, fire hydrants, firepumps, post indicator valves, sectional valves, fire extinguisher cabinets, electromagnetic doorhold open devices, wall sections indicating fire resistive ratings, and evacuation plan signage.Submit draft specifications for fire alarm and suppression systems.Part I: Basic Solicitation Requirements – Page 37 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]G. MechanicalSubmit completed design narrative and calculations for HVAC systems. Include room-byroom,peak zone-by-zone, and building block heating and cooling loads. Discuss selection <strong>of</strong>HVAC equipment and provide catalog cuts <strong>of</strong> equipment. Provide room-by-room heating andcooling loads, zone–by-zone heating and cooling loads; and building block heating and coolingloads. Include Psychometric chart for air handling unit, coil entering and leaving conditions,fan motor heat gains, consumption <strong>of</strong> humidification loads, sound/acoustic analysis. Provideroom-by-room air balance charts. Show supply, return, exhaust, make-up, and transferquantities with intended pressure relationships, i.e., positive, negative, or zero with respect toadjoining spaces.Submit completed design development drawings indicating: main supply, return and exhaustductwork, volume dampers, fire and smoke partitions, fire and smoke dampers, smokedetectors, automatic control dampers, air quantities for each room, air inlets/outlets, rises anddrops in ductwork, and interconnection <strong>of</strong> HVAC equipment with fire protection equipment (seefire protection). Provide plan and section <strong>of</strong> mechanical equipment rooms and buildingcorridors (show routing <strong>of</strong> main ductwork, plumbing, fire protection, major conduit or cable trayruns). Provide schematic flow and riser diagrams, schematic control diagrams, and equipmentschedules. Indicate required seismic bracing. Provide legends, symbols, and abbreviations.Submit draft specifications for mechanical systems and equipment.H. PlumbingSubmit completed design narrative addressing plumbing systems including supply, waste, andmedical or laboratory gas systems. Submit calculations for piping systems and equipment.Submit completed design development drawing. In addition to the requirements <strong>of</strong> the firstdesign development submittal, show the following: size <strong>of</strong> pipe, equipment schedule, fire andsmoke partitions, riser diagrams, legend, notes, and details; location and size <strong>of</strong> sprinklerriser, standpipes, and fire pumps (see fire protection); and location <strong>of</strong> emergency eyewashand shower equipment.Submit draft specifications for plumbing systems and equipment.I. ElectricalShow all new services to building, utility transformers, location, exterior lighting, and the utilityservice point and meter location on the electrical site plan. Submit a written summary <strong>of</strong> anyconversations with the electrical utility.Provide legend <strong>of</strong> symbols and abbreviations. Submit a full set <strong>of</strong> electrical lighting, power,and lightning protection plans for building and site. Submit one-line diagrams <strong>of</strong> the normalelectrical power distribution system and the emergency power system.Provide prefinal fault current, generator sizing, load, feeder, and equipment sizing, voltagedrop, lightning protection risk analysis, and lighting and energy calculations.Submit draft specifications for electrical equipment.J. Telecommunications and Special SystemsSubmit completed design narrative.Part I: Basic Solicitation Requirements – Page 38 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Submit Telecommunications and Special Systems site and building drawings. Identify lowvoltageoutlet connections and major equipment items. Include basic cable tray routing andfloor penetration location for routing <strong>of</strong> low-voltage cabling.Submit ¼-inch scale enlarged Telecommunication Rooms plans. Identify equipment racklocation, overhead ladder rack, and wall field equipment with proper clearances. Submit 1-inch scale enlarged plans <strong>of</strong> the rack details including termination areas <strong>of</strong> copper and fibercabling and equipment layout.Submit draft specifications for Telecommunications and Special Systems.3.20.4 75% CONSTRUCTION DOCUMENTSA. SiteThe Site drawings shall indicate all site features required by the lease documents, e.g.,topography (1 foot contours), building location by legal description, site setbacks, grading,parking, roadways, access ways, pedestrian routes, landscaping, irrigation system, //MRIpad,// //gazebo,// smoking shelter, sidewalks, conformance with local design standards, etc.The site drawing shall be at a minimum scale <strong>of</strong> 1" = 40’. Provide specifications for siteimprovements.The site drawings shall reference the Geotechnical Report for drainage design, pavementdesign recommendations, and slope stability, etc.Include a Hydrology and Hydraulic analysis and report in support <strong>of</strong> the proposed designwhich complies with local, state, and federal flood plain management standards andmethodologies. It is not acceptable to connect storm drain systems to the sanitary system.The Site drawings shall include details for connecting to the public water distribution system.Include points <strong>of</strong> connection, zone boundaries, fire hydrants (spaced per local codes),domestic and irrigation meter size and location, and all other water distribution components asrequired by the local water utility.The Site drawings shall include details for connecting to the public wastewater system.Include the downstream point <strong>of</strong> connection, manholes, and cleanouts, etc., per the standardsand specifications <strong>of</strong> the local wastewater jurisdiction. The proposed wastewater systemcannot be designed to be integrated with the storm drain system.Include detailed drainage plans based on the Hydrology and Hydraulics Report that identifylocation and depth <strong>of</strong> basins, storm sewer, catch basins, channels, connection points, pipestructures and all other drainage related items, as proposed in the report or required by thelocal jurisdiction.B. StructuralSubmit 75% complete structural drawings including foundation plans, floor and ro<strong>of</strong> framingplans, sections, elevations, general notes, schedules, and details. Coordinate floor or ro<strong>of</strong>depressions and penetrations with architectural, mechanical, plumbing, and electrical work.Indicate major mechanical, electrical, and other special equipment items, and show chases orshafts. Show framing and support required at those locations.Part I: Basic Solicitation Requirements – Page 39 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Submit calculations for gravity and lateral (wind/seismic) load requirements. Submit structuralspecifications.C. ArchitecturalSubmit 75% complete architectural drawings including fully dimensioned floor plans showingall revisions required by comments from the design development phase. Submit interiordetails, elevations, and sections. Submit complete and coordinated finish, door, hardware,and window schedules. Submit ro<strong>of</strong> plans, building sections, wall sections, and exteriorelevations that show finish floor elevations and indicate all building systems and materials.Submit completed, coordinated reflected ceiling plans for entire building, indicating all ceilingmounted equipment, lighting fixtures, air diffusers, registers, tracks, etc. Submit 1/4-inch scaleequipment plans, elevations, schedules, and details. Submit general notes, symbol legends,abbreviations, and all necessary and coordinated interior and exterior details. Submit fullyedited specifications.D. Interior Design(1) Fabrication <strong>of</strong> Sample BoardsProvide 2 complete sets <strong>of</strong> sample boards. Distribution will be Contracting <strong>Office</strong>r-1 set,VAMC-1 set. Sample boards are not returnable. Designer should fabricate an extra copy <strong>of</strong>each submission for their records.Identify each sample board with project and location information.(2) Product SamplesOrganize the finish and material samples on the boards to clearly convey the design intent.Apply an actual sample <strong>of</strong> all interior and exterior materials, finishes and paints specified onthe project. Securely adhere all samples with a strong adhesive and/or double sided foamtape. Place exterior materials on a separate board. Assign a color and material code to allsamples.(3) Sample BoardsUse mat board, foam core or any other suitable lightweight material. Board size should notexceed 30" x 40". Use a white board. Backer boards <strong>of</strong> other colors may be used forbordering. Do not use frames.(4) Signage and WayfindingSubmit drawing(s), specifications, and narrative to illustrate the wayfinding concept andsignage systems proposed for the project. Include all graphics and signage that are to beprovided as part <strong>of</strong> the solicitation.E. Sustainable Design and Energy EfficiencySubmit final documentation demonstrating LEED® Silver equivalency. Where proposedCredits will not achieve all federally-mandated strategies for sustainability and energyefficiency, submit documentation showing compliance with federally-mandated strategies.Submit final ASHRAE 90.1-2004 base-case energy model and as-designed energy modelbased on the <strong>Construction</strong> Documents, including all assumptions used, demonstratingcompliance with the 30% energy reduction goal. Submit final models for all other systems.Submit final commissioning specifications.Part I: Basic Solicitation Requirements – Page 40 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]F. Fire Protection/Life SafetySubmit 75% complete fire protection drawings. In addition to the drawing requirements <strong>of</strong> theSecond Design Development submission, include the following:Door and window schedule indicating fire rating and whether fire rated glazing will beprovided;Height and configuration <strong>of</strong> storage racks and shelving in relation to fire sprinkler heads;Reference note to HVAC drawings that indicates interconnection <strong>of</strong> HVAC systemcomponents (dampers, fans) with duct smoke detectors and/or fire alarm system;When fire pump is required, submit details <strong>of</strong> the fire pump system, including elevation andisometric detail <strong>of</strong> fire pump, and interconnection <strong>of</strong> the fire pump system to the fire alarmsystem;Show zoning <strong>of</strong> each fire alarm initiating device, single line riser diagram for the fire alarmsystem, and detail <strong>of</strong> annunciator panel;//For multi-story buildings, submit details <strong>of</strong> the stairwell sign, indicating stairwell number, floornumber, and upper and lower floor terminus <strong>of</strong> stairwell, and interconnection <strong>of</strong> elevatorcontrols with fire alarm system;////Interconnection <strong>of</strong> kitchen fire extinguishing system to the fire alarm system;//Provide final calculations.Submit fire protection specifications.G. MechanicalProvide complete and final engineering calculations <strong>of</strong> all systems. In addition tospecifications, provide complete selection data, including catalog cuts and calculations, for allHVAC equipment and drawings showing all equipment schedules. Complete the coordinationrequirements with fire protection, electrical, plumbing, architectural (louvers, ceiling accesspanels, reflected ceiling plans, etc.), and structural work (operating weights <strong>of</strong> ceiling and floormounted equipment, concrete and steel supports, ro<strong>of</strong> and floor openings, etc.). Submit 75%complete HVAC floor plans for all areas, showing all ductwork and piping at 1/8-inch scale.Submit 75% complete HVAC floor plans for all mechanical equipment rooms with at least twocross-sections taken at right angles to each other at ¼-inch scale. Show all equipmentlocated on ro<strong>of</strong> and/or grade.H. PlumbingSubmit 75% complete and coordinated drawings to include riser diagrams, legend, notes anddetails. Submit specifications and final calculations.I. ElectricalComplete the site and building electrical lighting, power, and lightning protection plans.Provide normal and emergency one-line riser diagrams including all conduit and cablequantities and sizes, complete ground system, and electrical equipmentPart I: Basic Solicitation Requirements – Page 41 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]amperage/voltage/phase/poles/AIC ratings. Show transformers, switchboards, panelboards,and feeders in relative positions. Tabulate all panelboard schedules. Provide specificationsand final calculations. Provide written approval by the utility company <strong>of</strong> the design <strong>of</strong> theelectrical incoming service.J. Telecommunications and Special SystemsShow all new services to building from service providers and/or inter-connections. Complete asite plan and a one-line riser diagram including all conduit, backbone cable. Providetelephone, data, security, and special systems risers. Identify all devices and locations.Complete the building low-voltage floor plans. Provide complete specifications for all lowvoltagesystems and final device locations.3.20.5 100% CONSTRUCTION DOCUMENTSAll disciplines: complete and coordinate all drawings, specifications, and schedules for 100%construction document submittal. Incorporate all VA and technical review comments. Provideseal (stamp) and signature <strong>of</strong> the responsible charged A/E on all construction documents andfinal calculations. Submit design team responses to review comments and QA/QCdocumentation with 100% document package for back check.The documents submitted to the Authorities Having Jurisdiction for plan review and permittingshall be the 100% construction documents with VA review comments incorporated.3.20.6 APPROVED PLANS AND PERMITSPrior to the start <strong>of</strong> construction, submit to VA copies <strong>of</strong> all permits and two complete sets <strong>of</strong>construction documents as approved by the Authorities Having Jurisdiction.3.21 PROJECT SCHEDULE3.21.1 NAS SCHEDULEThe Lessor shall develop a Network Analysis System (NAS) plan and schedule demonstratingfulfillment <strong>of</strong> the contract requirements, shall keep the network up-to-date in accordance withthe requirements <strong>of</strong> this paragraph, and shall utilize the plan for scheduling, coordinating, andmonitoring work under this lease contract (including all activities <strong>of</strong> subcontractors, equipmentvendors, and suppliers). Conventional scheduling techniques shall be utilized to satisfy timeapplications. All schedule data and reports required under this paragraph shall be based uponregular total float schedules. The Lessor shall designate an authorized representative in thefirm who will be responsible for the preparation <strong>of</strong> the network diagram and will review andreport progress <strong>of</strong> the project with and to the Contracting <strong>Office</strong>r or designee. The Lessor’sdesignated representative shall have direct project control and complete authority to act onbehalf <strong>of</strong> the Lessor in fulfilling the requirements <strong>of</strong> this paragraph, and such authority shall notbe interrupted throughout the duration <strong>of</strong> the project.3.21.2 SCHEDULE UPDATESThe Lessor shall provide to VA monthly computer-generated schedule report updates. TheLessor is responsible for the timely submission and correctness <strong>of</strong> the monthly reportsprovided to the Contracting <strong>Office</strong>r or designee. VA shall report errors in the reports to theLessor’s representative within seven (7) calendar days from receipt <strong>of</strong> reports. The LessorPart I: Basic Solicitation Requirements – Page 42 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]3.21.3 DATESshall reprocess the reports when requested by the Contracting <strong>Office</strong>r or designee, to correcterrors that affect the schedule for the project.The successful Lessor shall provide a combined project schedule for design and construction.Within 45 calendar days after award, the Lessor shall submit to the Contracting <strong>Office</strong>r ordesignee a project schedule giving the dates on which the various phases <strong>of</strong> design andconstruction will be completed to coincide with the Government's required occupancy date(refer to Paragraph 1.6 <strong>of</strong> this Solicitation). The schedule shall clearly indicate the completion<strong>of</strong> significant activities/events, including but not limited to:Submittal <strong>of</strong> completed First Design Development PackageSubmittal <strong>of</strong> completed Second Design Development PackageSubmittal <strong>of</strong> 75% <strong>Construction</strong> DocumentsSubmittal <strong>of</strong> 100% <strong>Construction</strong> DocumentsIssuance <strong>of</strong> a Building PermitSubmittal to VA <strong>of</strong> copies <strong>of</strong> Permits and Approved <strong>Construction</strong> DocumentsStart <strong>of</strong> constructionCompletion <strong>of</strong> principal categories <strong>of</strong> workTesting and balancingBuilding Systems CertificationFinal inspectionFinal completion <strong>of</strong> constructionOccupancy permit3.21.4 ACTIVITIESThe schedule shall contain approximately //1,000// //____// activities/events and shall break upthe work into activities/events <strong>of</strong> duration no longer than 20 work days each, except as to nonconstructionactivities/events (i.e., submittal <strong>of</strong> shop drawings, submittal review, fabrication,procurement <strong>of</strong> materials and equipment, delivery <strong>of</strong> materials and equipment, concrete andasphalt curing, testing and balancing, etc.) and any other activities/events for which theContracting <strong>Office</strong>r or designee may approve the showing <strong>of</strong> a longer duration. The durationfor VA approval <strong>of</strong> any required submittal, shop drawing, or other submittals shall not be lessthan 15 calendar days.The schedule shall describe work activities/events clearly, so the work is readily identifiable forassessment <strong>of</strong> completion. Activities/events labeled "start," "continue," or "completion," arenot specific and will not be allowed. Lead and lag time activities will not be acceptable.3.21.5 GOVERNMENT REVIEWTo the extent that the network diagram or any revised network diagram shows anything notjointly agreed upon, it shall not be deemed to have been approved by the Contracting <strong>Office</strong>ror designee. Failure to include any element <strong>of</strong> work required for the performance <strong>of</strong> thisPart I: Basic Solicitation Requirements – Page 43 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]contract shall not excuse the Lessor from completing all work required within any applicablecompletion date <strong>of</strong> each phase regardless <strong>of</strong> the Contracting <strong>Office</strong>r or designee approval <strong>of</strong>the network diagram.3.22 PROGRESS REPORTSAfter receipt <strong>of</strong> VA approved Second Design Development Submittal, the successful Lessorshall submit to the Contracting <strong>Office</strong>r or designee written progress reports every 30-calendardays, based upon the monthly updated NAS. The report shall include information as topercentage <strong>of</strong> the work completed by phase and trade, a statement as to expected completionand occupancy dates, changes introduced into the work, and general remarks on such itemsas material shortages, strikes, weather, or the like.3.22.1 REMEDIAL ACTIONWhenever it becomes apparent from the current monthly updated schedule that phasing orcontract completion dates will not be met, the Lessor shall execute some or all <strong>of</strong> the followingremedial actions: Increase construction manpower in such quantities and crafts as necessary toeliminate the backlog <strong>of</strong> work. Increase the number <strong>of</strong> working hours per shift, shifts per working day, working daysper week, the amount <strong>of</strong> construction equipment, or any combination <strong>of</strong> the foregoingto eliminate the backlog <strong>of</strong> work. Reschedule the work in conformance with the solicitation requirements.The Lessor shall notify the Contracting <strong>Office</strong>r or designee as to what actions are being takento mitigate the proposed schedule changes. The project schedule revisions shall beincorporated by the Lessor into the network diagram before the next update, at no additionalcost to the Government.3.22.2 REVISIONS TO SCHEDULEWithin 10 calendar days after any project progress schedule update, the Lessor shall submit arevised project schedule for any <strong>of</strong> the following reasons:Delay in completion <strong>of</strong> any activity/event or group <strong>of</strong> activities/events that indicates anextension <strong>of</strong> the project completion by 20 working days or 10% <strong>of</strong> the remaining projectduration, whichever is less. Such delays, which may be involved with contract changes,strikes, unusual weather, and other delays, will not relieve the Lessor from the requirementsspecified unless the conditions are shown on the schedule as the direct cause for delaying theproject beyond the acceptable limits.Delays in submittals, or deliveries, or work stoppage are encountered which makerescheduling <strong>of</strong> the work necessary.The schedule does not represent the actual execution and progress <strong>of</strong> the project.Project schedule revisions made under this paragraph that affect the previously approvedcomputer-produced schedules for Government furnished equipment, contract phase(s) andPart I: Basic Solicitation Requirements – Page 44 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]sub-phase(s) or any other previously contracted item, must be furnished in writing to theContracting <strong>Office</strong>r or designee for approval.3.22.3 APPROVAL OF SCHEDULEThe Contracting <strong>Office</strong>r or designee approval for the revised network diagram and all relevantdata is contingent upon compliance with all other paragraphs <strong>of</strong> this section and any otherprevious agreements by the Contracting <strong>Office</strong>r or designee.3.22.4 COSTS OF REVISIONSThe cost <strong>of</strong> revisions to the network diagram resulting from contract changes will be includedin the proposal for changes in work as specified in Paragraph 3.8, Contract Changes, <strong>of</strong> thisSolicitation, and will be based on the complexity <strong>of</strong> the revision or contract change, man hoursexpended in analyzing the change, and the total cost <strong>of</strong> the change.The cost <strong>of</strong> revisions to the network diagram not resulting from contract changes is theresponsibility <strong>of</strong> the Lessor.3.23 CONSTRUCTION OBSERVATIONObservations <strong>of</strong> the work during construction will be made periodically by the Contracting<strong>Office</strong>r and/or the designated Contracting <strong>Office</strong>r’s Technical Representative (COTR) toreview compliance with the Solicitation requirements and the final working drawings.Periodic reviews, tests, and other field observation by the Government are not to beinterpreted as superintendence nor as resulting in any approval <strong>of</strong> the Lessor's apparentprogress toward meeting the Government's objectives; but are intended to discover anyinformation that the Contracting <strong>Office</strong>r may be able to call the Lessor's attention to preventcostly misdirection <strong>of</strong> effort. The Lessor will remain completely responsible for designing,constructing, operating, and maintaining the building in full accordance with the requirements<strong>of</strong> this Solicitation.The Lessor shall provide VA with a copy <strong>of</strong> all inspection reports for inspections conducted bylocal, regional, and state code authorities from the start <strong>of</strong> construction through issuance <strong>of</strong> thecertificate <strong>of</strong> occupancy.3.23.1 RESIDENT ENGINEER’S OFFICE SPACEThe Lessor shall provide a temporary field <strong>of</strong>fice, furniture, and two-inch deep gravel-surfacedparking area for use <strong>of</strong> the Resident Engineer. <strong>Office</strong> and furniture shall be new or in "likenew" condition.A. Temporary Field <strong>Office</strong>The field <strong>of</strong>fice shall provide not less than // 720 gross square feet // 1,440 gross square feet //<strong>of</strong> floor area in one unit. Installation <strong>of</strong> the <strong>of</strong>fice shall meet all local codes.Provide <strong>of</strong>fice with two 3-foot wide exterior doors, including hardware and OSHA approvedplatform and stairs leading to grade. A stainless steel lock guard shall be provided overdeadbolts on exterior at each door.Part I: Basic Solicitation Requirements – Page 45 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Enclose the entire perimeter <strong>of</strong> the <strong>of</strong>fice from the floor to the ground and finish to matchexterior. Provide R7 insulation and seal tight to ground with a painted ¾-inch exterior gradeplywood skirt.Exterior finishes shall be manufacturer's standards.Provide floor, wall, and ro<strong>of</strong> with not less than R5 insulation.Interior finishes shall consist <strong>of</strong> resilient flooring, plywood paneling or painted wallboard onwalls, and acoustical tile ceilings. Interior doors may be either painted or stained.Interior shall be subdivided with full height partitions to provide // one <strong>of</strong>fice, // two <strong>of</strong>fices, //one sample room, one conference room, // one toilet // two separate toilets //. Provide eachspace with three-foot wide door with master keyed locks. Section <strong>of</strong>f an area with a lowpartition and counter for the administrative assistant's desk // s //.Provide 2-1/2 ft wide x 3 ft high operable windows; two in each room (none required in sampleroom), except provide only one 2-foot high window with frosted glass in toilet room(s). Providesteel mesh over all glass in doors and windows. The windows shall have mini-blinds.Provide sufficient fluorescent lighting in each room to deliver 30-foot candles <strong>of</strong> light atdesktop height without the aid <strong>of</strong> daylight. Provide one light switch in each room. Provide onecord-connected, portable 24-inch fluorescent task light at each secretarial workstation and<strong>of</strong>fice desk.Provide one quadraplex receptacle in each wall <strong>of</strong> each room. If a wall is 10 feet long or more,provide two quadraplex receptacles for each 10 feet, or portion there<strong>of</strong>, <strong>of</strong> wall. Provide twoquadraplex receptacles in low partition at administrative assistant's desk.B. Utilities and ServicesThe Lessor shall provide the following:Electricity, hot and cold water, and necessary utility services (except telephone).All necessary piping, power circuits, electrical fixtures, lighting, and other items necessary toprovide a habitable structure for the purpose intended.Thermostatically controlled, centralized heating and air conditioning system designed tomaintain the temperature between 70 and 80 degrees F with 50% relative humidity. Therelative humidity shall be uncontrolled.One water closet, lavatory, mirror, toilet paper dispenser, paper towel dispenser, soapdispenser, towel bar, and two-prong coat hooks for each toilet room.Telephone and Internet connections: Provide //three (3) telephone lines// //two (2) telephonelines and one (1) Internet cable service// //[ insert required services ]//.Lessor shall, for the duration <strong>of</strong> the Resident Engineer's occupancy, provide the following:Shall be responsible for cost <strong>of</strong> utilities.Secure, safe, and sanitary conditions in and around the field <strong>of</strong>fice and parking area.Part I: Basic Solicitation Requirements – Page 46 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Maintenance <strong>of</strong> gravel surfaced area, including the area for parking, in an acceptablecondition for vehicle and foot traffic at all times. Maintenance <strong>of</strong> utility services. //Daily janitorial services and supplies (toilet paper, soap, etc.). //Potable water, fuel, and electric power for normal <strong>of</strong>fice uses, including lights, heating,and air conditioning.Lessor shall be responsible for all maintenance for field <strong>of</strong>fice and equipment includingreplacement <strong>of</strong> burned out light bulbs or tubes and changing <strong>of</strong> A/C filters.C. Furnishings and EquipmentThe Lessor shall provide the following new or "like" new reconditioned items:QUANTITY REQUIRED//1 Administrative assistant workstation with adjustable keying desk or drawer size 29-1/2" H x 60"W x 30" D1 Printer stand, size 26-1/2" H x 60" W x 30" D3 <strong>Office</strong> desks, double pedestal1 Conference table, size 3' x 6'1 Plan table 4' x 7'3 Work tables, folding 30" x 72"1 Secretary chair4 Swivel chairs with arms6 Conference chairs (armless and folding)2 Arm chairs4 5 drawer file cabinets, letter size1 Drawing rack, with 12-30 inch "Plan Hold" drawing holders, freestanding1 Shelves for sample room, 7 adjustable shelves, 12" W x 3' L3 Bookcases1 Electric water cooler1 Metal storage cabinet, 36" x 18" x 72" with six shelves ////2 Administrative assistant workstations with adjustable keying desk or drawer size 29-1/2" H x60" W x 30" D2 Printer stands, size 29-1/2" H x 60" H x 30" D7 <strong>Office</strong> desks, double pedestal2 Conference tables, size 3' x 6'Part I: Basic Solicitation Requirements – Page 47 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]1 Plan table 4' x 20'7 Work tables, folding 30" x 72"2 Secretary chairs7 Swivel chairs with arms12 Conference chairs (armless and folding)7 Arm chairs8 5 drawer file cabinets, letter-size2 Drawing racks, each with 12-30 inch "Plan Hold" drawing holders, freestanding7 Bookcases1 Electric water cooler4 Shelves for sample 36" x 18" x 72" high, 7 adjustable shelves //D. Disposition <strong>of</strong> Field <strong>Office</strong> at Completion <strong>of</strong> <strong>Construction</strong>At the completion <strong>of</strong> all work, including the punch list, the Resident Engineer's field <strong>of</strong>fice andfacilities, except 5 drawer file cabinets shall become the property <strong>of</strong> the Lessor, and Lessorshall remove same, including utility connections, from the site. The site shall be restored tooriginal condition and finished in accordance with contract requirements.E. Submittal <strong>of</strong> Plans for Field <strong>Office</strong>The Lessor shall furnish floor plans for approval by the Resident Engineer prior to furnishingthe field <strong>of</strong>fice.3.24 SAMPLES AND SHOP DRAWINGSThe Lessor shall provide submittals to the Government for approval <strong>of</strong> all materials andequipment in accordance with this solicitation. The Government accepts no responsibility forchecking schedules or layout drawings for exact sizes, exact numbers, or detailed positioning<strong>of</strong> items. Approval by the Government does not relieve the Lessor <strong>of</strong> the responsibility <strong>of</strong>complying with the requirements <strong>of</strong> the specifications and lease.3.25 CONSTRUCTION WASTE MANAGEMENTRecycling construction waste is mandatory for initial space alterations for tenant improvementsand subsequent alterations under the lease. Recycling construction waste means providing allservices necessary to furnish construction materials or wastes to organizations which willemploy these materials or wastes in the production <strong>of</strong> new materials. Recycling includesrequired labor and equipment necessary to separate individual materials from the assemblies<strong>of</strong> which they form a part. Refer to Paragraph 4.8 SUSTAINABLE DESIGN AND ENERGYEFFICIENCY.3.26 USE OF FACILITY PRIOR TO DATE OF POSSESSIONSpace shall be delivered ready for occupancy by the date specified in Paragraph 1.6 <strong>of</strong> theSolicitation provided; however, subject to mutually satisfactory arrangements between thePart I: Basic Solicitation Requirements – Page 48 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Lessor and the Contracting <strong>Office</strong>r, the Government may enter the premises at any timesubsequent to award <strong>of</strong> the contract to conduct such ceremonies as ground-breaking,cornerstone laying, and dedication, and may occupy such portions <strong>of</strong> the property as may benecessary for such purposes. Further, the Lessor agrees to prohibit the conducting <strong>of</strong> suchceremonies in the leased premises or on the site there<strong>of</strong> arranged by parties other thanrepresentatives <strong>of</strong> VA unless written approval is obtained from the Contracting <strong>Office</strong>r.3.27 PLANS: AFTER OCCUPANCYWithin 30 days after occupancy, the following as-built plans for the building under lease shallbe provided to the Contracting <strong>Office</strong>r or designee. If the plans are not provided, VA will havethe plans prepared at the Lessor's expense.One set <strong>of</strong> mylar reproducible architectural floor plans, scaled at 1/8" = 1"-0".One set <strong>of</strong> mylar reproducible equipment plans, scaled at 1/4" = 1’-0".Purged computer files <strong>of</strong> architectural floor plans, and equipment plans in //AutoCAD 2009////____// format, shall be submitted on CD-ROM or DVD, properly labeled and indexed.Submission shall be accompanied with a written matrix, indicating the layering standards toensure that all information is recoverable. All architectural features <strong>of</strong> the spaces shall beaccurately shown.3.28 PARTNERINGIn order to accomplish this contract effectively, the Government proposes to form a cohesivepartnership with the successful Offeror and its subcontractors. This partnership would strive todraw on the strengths <strong>of</strong> each organization in an effort to achieve a quality project, executedcorrectly the first time, within the budget, and on schedule. This partnership will be totallyvoluntary. The focus <strong>of</strong> partnering is to build a cooperative relationship with the private sectorand avoid or minimize disputes, and to nurture a more collaborative ethic characterized bytrust, cooperation, and teamwork. Partnering is defined as the creation <strong>of</strong> a relationshipbetween the Government and the successful Offeror that promotes mutual and beneficialgoals. It is a non-contractual, but formally structured, agreement formation <strong>of</strong> a "we" mentalityfor the benefit <strong>of</strong> the project. Any cost associated with developing this partnership will beagreed to by both parties after contract award, and will be shared equally with no change incontract price.3.29 VAAR-85273-75 SECURITY REQUIREMENTS FOR UNCLASSIFIEDINFORMATION TECHNOLOGY RESOURCES (INTERIM – OCTOBER 2008)The contractor and their personnel shall be subject to the same Federal laws, regulations,standards, and VA policies as VA personnel regarding information and information systemsecurity. These include, but are not limited to, Federal Information Security <strong>Management</strong> Act(FISMA), Appendix III <strong>of</strong> OMB Circular A-130, and guidance and standards, available from theDepartment <strong>of</strong> Commerce's National Institute <strong>of</strong> Standards and Technology (NIST). This alsoincludes the use <strong>of</strong> common security configurations available from NIST's website at:http://checklists.nist.gov.Part I: Basic Solicitation Requirements – Page 49 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]To ensure that appropriate security controls are in place, contractors must follow theprocedures set forth in "VA Information and Information System Security/PrivacyRequirements for IT Contracts" located at the following website: http://www.iprm.oit.va.gov.Part I: Basic Solicitation Requirements – Page 50 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]SECTION 4 GENERAL DESIGN CRITERIA4.1 CODESThe Lessor shall design and construct the building and site work in accordance with thissolicitation, all applicable Federal regulations, local Building and Zoning Codes andordinances, and applicable utility company requirements. The term "local building and zoningcodes and ordinances," or similar text, shall be understood to mean the current codes andregulations as approved and administered by Authorities Having Jurisdiction (AHJ) at theproject location at the time <strong>of</strong> permitting. Where there is a conflict between the various codesor standards, the most stringent shall apply.4.2 CRITERIA FOR VA FACILITIES4.2.1 VA ADOPTED CODES, STANDARDS, AND EXECUTIVE ORDERSThe Public Buildings Amendment Act <strong>of</strong> 1988, Public Law (Pub. L.) 100-678 requires Federalagencies to follow national recognized "model" building codes. The Federal Participation inthe Development and Use <strong>of</strong> Voluntary Standards, <strong>Office</strong> <strong>of</strong> <strong>Management</strong> and Budget (OMB)Circular A-119, requires all executive agencies to rely on voluntary standards, both domesticand international, whenever feasible, and to participate in voluntary standard bodies. As aFederal agency, VA is required to comply with Executive Orders.VA has adopted the following codes and standards as a minimum for all projects performed inthe modernization, alteration, addition, or improvement <strong>of</strong> its real property and the construction<strong>of</strong> new structures. Applicable requirements have been incorporated in this Solicitation forOffers.CODES / STANDARDSAIA/FGI (American Institute <strong>of</strong> Architects/Facility Guidelines Institute):Guidelines for Design and <strong>Construction</strong> <strong>of</strong> Healthcare <strong>Facilities</strong>ANSI/ASHRAE Standard 62.1 – Ventilation for Acceptable Indoor Air QualityANSI/ASHRAE Standard 90.1 – Energy Standard for Buildings except Low-Rise Residential Buildings(Use ASHRAE Standard 90.1 – 2004 for computing energy benchmark.)ANSI/ASHRAE Standard 15 – Safety Standard for Refrigeration SystemsEDITION20062007 (subjectto revision)2007 (subjectto revision(subject torevision)ANSI/ASHRAE Standard 170 – Ventilation <strong>of</strong> Healthcare <strong>Facilities</strong> 2008Architectural Barriers Act Accessibility Standards (ABAAS, 36 CFR Part 20041191)ASHRAE Handbook <strong>of</strong> Fundamentals 2005ASHRAE Handbook <strong>of</strong> Refrigeration 2006ASHRAE Handbook <strong>of</strong> Applications 2007ASHRAE Handbook <strong>of</strong> Systems and Equipment 2008ASME Boiler and Pressure Vessel Code 2007ASME Code for Pressure Piping 2004Part I: Basic Solicitation Requirements – Page 51 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]CODES / STANDARDSEDITIONASPE Data Book, Volume 1: Fundamentals <strong>of</strong> Plumbing Engineering 2004ASPE Data Book, Volume 2: Plumbing Systems 2004ASPE Data Book, Volume 3: Special Plumbing Systems 2004Building Code Requirements for Reinforced Concrete, American Concrete 2008Institute and Commentary (ACI 318)International Building Code (IBC), with the exception <strong>of</strong> Chapter 10, unless 2009locally adoptedInternational Energy Conservation Code (IECC) 2009International Fuel Gas Code (IFGC) 2009International Mechanical Code 2006International Plumbing Code (IPC) 2009Manual <strong>of</strong> Steel <strong>Construction</strong>, Load and Resistance Factor Design2005Specifications for Structural Steel Buildings, American Institute <strong>of</strong> Steel<strong>Construction</strong> (AISC)NFPA 101 – Life Safety Code 2009All Remaining NFPA National Fire Codes with the exception <strong>of</strong> NFPA 5000and NFPA 900National Standard Plumbing Code (NSPC) 2006Occupational Safety & Health Administration (OSHA) Standards (Healthcare) 2004Current aspublished inMay 2009Safety Code for Elevators and Escalators, American Society <strong>of</strong> Mechanical 2007Engineers (ASME) A 17.1Safety Standard for Refrigeration Systems – ASHRAE Standard 15 2007SMACNA – HVAC Duct <strong>Construction</strong> Standards: Metal & Flexible2005, 3 rdEditionSMACNA – HVAC Air Duct Leakage Test Manual 1985VA Barrier Free Design Guide, PG-18-13 2007US Pharmacopeia (USP) Revised General Chapter Pharmaceutical 2008Compounding-Sterile PreparationsVA Physical Security Design Manual – Life-Safety Protected 2007VA Seismic Design Requirements, H-18-8 2008VHA National CAD Standard Application Guide 2006A. Life SafetyNFPA 101 primarily addresses life safety and fire protection features, while the IBC addressesa wide range <strong>of</strong> considerations, including, but not limited to, structural strength, seismicstability, sanitation, adequate light and ventilation, and energy conservation. VA buildingsmust meet the requirements <strong>of</strong> NFPA 101 and documents referenced by NFPA 101 in order tocomply with the accreditation requirements <strong>of</strong> the Joint Commission. Therefore, designs shallcomply with the requirements <strong>of</strong> NFPA 101 and documents referenced therein. Designfeatures not addressed by NFPA 101 or documents referenced therein shall comply with therequirements <strong>of</strong> the IBC.Part I: Basic Solicitation Requirements – Page 52 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]B. Mandatory Provisions for Energy ConservationFederally mandated statutory requirements for energy conservation are also applicable to theleased facilities. These requirements include:(1) Federal Leadership in High Performance and Sustainable Buildings: MOU(Memorandum <strong>of</strong> Understanding) Dated November 2006This document was signed by 21 Federal Agencies under the Federal Leadership in HighPerformance and Sustainable Buildings. The stated goals and objectives <strong>of</strong> the MOU are:New <strong>Construction</strong>: Reduction in the Energy Cost Budget by 30% over the Baselineperformance rating <strong>of</strong> ASHRAE Standard 90.1 – 2004.Reduction in the energy cost budget shall be implemented as the reduction in energyconsumption measured as BTU (British Thermal Units) or Joules (J).For major renovations, reduce the energy cost budget by 20% below pre-renovations 2003baseline. In the event pre-renovation 2003 baseline data is not available, the A/E shallcalculate the energy consumption before renovation, compare it with the energy consumptionafter renovation, and document the mandated saving. It is assumed that the use <strong>of</strong> the facilityshall remain similar before and after the renovation. The term "major renovation" shall meetthe following two guidelines: Area <strong>of</strong> renovation is greater than 50% <strong>of</strong> the total area. A project is planned that significantly extends the building's useful life throughalterations or repairs and totals more than 30% <strong>of</strong> the replacement value <strong>of</strong> the facility.Additional issues addressed by MOU are:Commissioning: For the leased facilities, commissioning <strong>of</strong> the mechanical and otherbuilding systems shall be implemented to verify the intent <strong>of</strong> the design by inspecting andtesting the systems.Measurements and Verification: Per DOE Guidelines issued under section 103 <strong>of</strong> theEnergy Policy Act <strong>of</strong> 2005 (EPAct), install building level utility meters in new majorconstruction and renovation projects to track and continuously optimize performance. MOUmandates that the actual performance data from the first year <strong>of</strong> operation should becompared with the energy design target. After one year <strong>of</strong> occupancy, measure all new majorinstallations using the Energy Star® Benchmarking Tool for building and space types coveredby ENERGY STAR® or FEMP-designated equipment.(2) Energy Policy Act (2005):DOE issued mandatory energy conservation guidelines as the final rule for implementingprovisions <strong>of</strong> EPAct 2005.(3) Executive Order 13423: Strengthening Federal Environmental, Energy, andTransportation <strong>Management</strong>Mandatory energy conservation guidelines are also reiterated in the above Executive OrderDOE has mandated that a new Federal building must be designed to achieve an energyconsumption level that is at least 30% below the level achieved under Standard 90.1-2004, iflife-cycle cost-effective.Part I: Basic Solicitation Requirements – Page 53 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]C. Life-Cycle Cost (LCC) Analysis (Requirements)If additional 30% reduction in energy consumption were not life-cycle cost-effective, the A/Emust evaluate alternate designs at successive decrements (25%, 20%, or lower) in order toidentify the most energy efficient design that is life-cycle cost-effective. And in so doing, allreadily available energy conservation measures, with which the industry is generally familiar,should be considered and evaluated.DOE further stipulates that the "agencies must estimate the life-cycle costs and energyconsumption <strong>of</strong> the planned building as designed and an otherwise identical building justmeeting the minimum criteria set forth in the applicable baseline ASHRAE or IECC standard."This measure is meant to demonstrate and record the mandated compliance and the extent <strong>of</strong>it.D. Life-Cycle Cost Analysis (Methodology)LCC shall be performed in accordance with the procedure outlined by the Department <strong>of</strong>Energy (DOE) in the National Institute <strong>of</strong> Standards and Technology (NIST) Handbook 135dated February 1996 (or the latest version) – Life-Cycle Costing Manual for the FederalEnergy <strong>Management</strong>.E. ConflictsShould a conflict exist between VA requirements and VA-adopted nationally recognized codesand standards, the conflict shall be brought to the attention <strong>of</strong> VA. The resolution <strong>of</strong> theconflict shall be made by the authority having jurisdiction for VA to ensure system-wideconsistency.4.2.2 SPECIAL BUILDING REQUIREMENTSA. Isolation Exam Room Requirements:Facility must comply with requirements <strong>of</strong> Center for Disease Control (CDC) "Guidelines forPreventing the Transmission <strong>of</strong> Mycobacterium Tuberculosis in Health-care <strong>Facilities</strong>,"MMWR, October 28, 1994, Vol. 43, No. RR-13. Lessor shall provide isolation exam roomswith the capability to treat undiagnosed patients who have symptoms <strong>of</strong> TB. Quantity andlocation <strong>of</strong> isolation exam rooms are indicated on the conceptual layout.HVAC systems and monitoring shall be as specified in Paragraph 6.4 MECHANICAL.B. Isolation Exam Room CertificationDuring HVAC systems balancing and/or commissioning, Lessor is responsible for certification<strong>of</strong> isolation exam rooms and the associated cost <strong>of</strong> certification <strong>of</strong> rooms. The Testing andBalancing report shall serve as certification that isolation rooms are under negative pressure.C. //Sterile Compounding Area////The sterile compounding area in //Pharmacy// //Chemotherapy Agent Preparation// room[insert room numbers here] shall comply with the requirements <strong>of</strong> United States Pharmacopeia(USP) . Specific features are shown on the conceptual drawings; Special Equipmentrequirements are in Schedule B; and special finishes are in Schedules C and E.HVAC system requirements are in Paragraph 6.4. Electrical requirements are in Paragraph6.7.//Part I: Basic Solicitation Requirements – Page 54 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]D. Water CoolersThe Lessor shall provide electric water coolers in the main lobby, each major waiting area, andin other areas as designated by the Contracting <strong>Office</strong>r. Lessor shall provide greater quantity<strong>of</strong> water coolers if required by Code. Water coolers shall be wall mounted bi-level electricwater coolers.E. Telecommunications/Special Systems RoomsDesign, size and construction <strong>of</strong> telecommunications, data, and special systems rooms andspaces shall comply with requirements in Paragraph 6.8.2TELECOMMUNICATIONS/SPECIAL SYSTEMS ROOMS AND SPACE REQUIREMENTS.F. Public TelephonesProvisions for two (2) public telephones shall be provided near the building entrance or mainlobby and shall be part <strong>of</strong> the building phone system with restrictions placed on extension toallow local calls only. Installation shall be designed and constructed to meet accessibilitycriteria.4.2.3 EXCLUSIONS FROM NET USABLE SPACEA. Housekeeping ClosetsA minimum <strong>of</strong> two (2) housekeeping aides closets (HAC) shall be provided for maintainingcommon areas in the building. Each HAC shall contain a service sink with hot and cold water,ample space for storage <strong>of</strong> cleaning equipment, and shelving for cleaning materials andsupplies. Lessor shall provide the supplies in accordance with SECTION 8 <strong>of</strong> this <strong>SFO</strong>. Norental will be paid for these spaces (see Paragraph 3.14 RENTABLE AND NET USABLESQUARE FEET <strong>of</strong> this Solicitation). In multi-story buildings, there shall be a minimum <strong>of</strong> oneHAC per floor.Provide additional housekeeping aides closets in leased spaces as required by VA SpaceProgram (PART VI Schedule E). VA will pay rental for HACs required by Schedule E.B. Public Restrooms and LoungesSpace for public toilets must be provided in addition to the net usable square footagerequirement contained in Schedule E <strong>of</strong> this Solicitation. VA will pay no rental for this publicrestroom facility space. See Paragraph 3.14 RENTABLE AND NET USABLE SQUARE FEET<strong>of</strong> this Solicitation.All public and common use toilet rooms shall be accessible to the handicapped. Accessibletoilet facilities shall be located along an accessible path <strong>of</strong> travel and have accessible fixtures,accessories, doors with automatic door openers, and adequate maneuvering clearances.Accessible toilet rooms shall be identified with the international symbol <strong>of</strong> accessibility. Waterclosets and urinals shall not be visible when the exterior room door is open.Separate toilet facilities for men and women shall be provided on each floor occupied by theGovernment in the building. The facilities must be located so that employees will not berequired to travel more than 150 feet on one floor to reach the toilets.Each toilet room shall have sufficient water closets enclosed with stall partitions and doors asspecified in Paragraph 7.14 <strong>of</strong> this Solicitation, urinals (in men's rooms), and lavatories withhot (set at 105 ˚F [41 ˚C], if practical) and cold water in the number required by local BuildingCode and ordinances.Part I: Basic Solicitation Requirements – Page 55 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Public restrooms that have three or more stalls shall be provided with one lighting fixture on anemergency circuit or one emergency battery lighting unit with dual head.Public Restrooms Fixture SchedulePublic restrooms and associated fixtures shall be provided in accordance with local code.C. Building Equipment and Service AreasLessor shall provide adequate space for the installation, operation, and maintenance <strong>of</strong>building service equipment. Lessor shall provide <strong>of</strong>fice, shop, and storage space necessaryfor operation and maintenance <strong>of</strong> the building and grounds. No rental will be paid for thesespaces (see Paragraph 3.14 <strong>of</strong> this Solicitation).Space for mechanical systems equipment.Space for plumbing systems equipment.Space for fire protection systems equipment.Space for electrical systems equipment.Space for telecommunications and special systems equipment (including telephone,data, alarm, security, and other systems).Space for building engineering control center.<strong>Office</strong>, shop, and storage space for building management services.Space for grounds maintenance.D. Public Corridors and Entrance LobbiesLessor shall provide building entrance //lobby// // lobbies// as shown on conceptual plans.Lessor shall provide public corridors as necessary to common areas. No rental will be paidfor these spaces (see Paragraph 3.14 RENTABLE AND NET USABLE SQUARE FEET <strong>of</strong>this Solicitation).E. Vertical CirculationSpace for vertical circulation includes stairs (and stair enclosures or vestibules), elevatorlobbies, elevator hoistways, and elevator machine rooms. No rental will be paid for thesespaces (see Paragraph 3.14 RENTABLE AND NET USABLE SQUARE FEET <strong>of</strong> thisSolicitation).F. Shafts and RisersProvide shafts, chases, and risers necessary for distribution <strong>of</strong> building services or utilities.No rental will be paid for these spaces (see Paragraph 3.14 RENTABLE AND NETUSABLE SQUARE FEET <strong>of</strong> this Solicitation).4.2.4 PHYSICAL SECURITY AND NATURAL DISASTERS RESISTIVE DESIGNThe requirements for "Life Safety Protected <strong>Facilities</strong>" (LSP) contained in the VA PhysicalSecurity Design Manual apply to all VA constructed or leased Outpatient Clinics. Lessor shallinclude the following provisions for Site Considerations, Building Entrances and Exits, BuildingEnvelope, Structural System, Utilities and Building Service, Building Systems, SecuritySystems, and Special Areas in the design and construction.Part I: Basic Solicitation Requirements – Page 56 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]A. Site Considerations(1) Site Access and RoadsSeparate entrances to the site shall be provided for patients and visitors, employees and staff,emergency and service and delivery vehicles. Access roads for all vehicles shall allow forseparate driveways to the building entrance, service yard or parking areas. Access roadsfrom the entrances to parking for each vehicle type shall be separated, but may be connectedfor maintenance and emergency vehicles through gates controlled by access cards.Access roads shall be configured to prevent vehicles from attaining speeds in excess <strong>of</strong>25 mph. Avoid any straight-line vehicular approaches to the facility.(2) Vehicle BarriersProvide passive barriers adjacent to vulnerable perimeter fences, protection for site utilityequipment, at building entrance, and other areas requiring additional protection from vehicles.Passive vehicle barrier shall be selected on the appropriateness <strong>of</strong> the architecture <strong>of</strong> thefacility and specifics <strong>of</strong> the site and natural environment. Natural or man-made barriers maybe used.Landscaping examples include berms, gullies, boulders, trees and other terrain.Hardscaping examples include benches and planters.Structural examples include walls, bollards and cables.(3) ParkingNo vehicle shall be parked or be permitted to travel close than 25 feet [7.62 m] to any lifesafetyprotected VA Facility.Parking and access for patients, visitors, and the persons transporting them to and from theVA facility shall be as convenient as possible to the main entrance, subject to therequirements above. Where vehicles are unscreened, make site provisions to accommodatea shuttle service for persons needing assistance. Parking and facility access shall comply withaccessibility requirements.Emergency entrance shall be provided with a small parking area for emergency patients andspace for ambulances. Ambulances shall be permitted to approach the building directly andnot be subjected to the distance requirements.Vendors shall use the delivery vehicle entrance and service yard at the loading dock. Parkingshall be provided for vendors in the service yard.Where employees share access with patients and visitors, the entrance to the employeeparking shall be controlled by a card-actuated gate. Employee parking areas shall bemonitored by SSTV. Emergency alert systems, such as blue phones, shall be provided at thediscretion <strong>of</strong> the VA Police.When separation <strong>of</strong> types <strong>of</strong> traffic is not feasible, card-controlled access gates and othertraffic separation measures shall be used.B. Building Entrances and ExitsPublic access to the facility should be restricted to //a single// //limited number <strong>of</strong>// entrances.The public entrance is to the main lobby <strong>of</strong> the facility. Staff entrances shall be locatedPart I: Basic Solicitation Requirements – Page 57 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]independently <strong>of</strong> main entrance lobbies and be convenient to staff parking. Design accessfrom drop-<strong>of</strong>f to lobby to prevent a straight line <strong>of</strong> travel. Provide sufficient size toaccommodate several people with mobility aids.Public access shall include a screening vestibule with sufficient space and power,telecommunications, and data connections for installation <strong>of</strong> access control and screeningequipment. When screening devices are not permanently installed, provide secure storage inclose proximity to their installation location.Entrance doors to the lobby shall be visible to or monitored by security personnel. Accessfrom the lobby to elevators, stairways, and corridors shall be controlled. Separate the publiclobby from adjacent areas with partitions that extend to the underside <strong>of</strong> the floor above.Glazing in the lobby area shall be laminated glass.Public doors shall be capable <strong>of</strong> being remotely locked and unlocked from the reception deskin the main lobby. Secondary public entrance doors shall prevent unauthorized access. Staffentrance door hardware shall include either mechanical or electronic locks.Means <strong>of</strong> egress doors that do not also function as entrances shall be provided with delayedaction and alarmed emergency egress hardware. Delayed egress and alarmed exits shallcomply with applicable codes and regulations. Means <strong>of</strong> egress shall not be obstructed byinstallation <strong>of</strong> security devices such as guard stations, screening equipment, or other securitydevices.Access for Emergency Responders: The Fire Command Center (FCC) and secure house keybox for emergency responders shall be located near an entrance door. The entrance shall becontrolled and monitored by Security Surveillance Television (SSTV).SSTV cameras shall be provided to monitor activities in the lobbies <strong>of</strong> new and existing lifesafetyprotected facilities and shall be located to provide views <strong>of</strong> approaching pedestrian andvehicular traffic, drop-<strong>of</strong>f areas, building entrances, and departing pedestrian and vehiculartraffic. Provide SSTV cameras at locations with alarmed exits, at loading docks, and otherareas subject to pilferage. Install door status monitors at doors intended to be used only foremergency egress.C. Building EnvelopeNon-load bearing walls shall be designed to withstand the design level vehicle threat. Wallsshall be able to accept the tributary loads transferred from glazed fenestration in addition tothe design level pressures applied directly to their surface.Façade fenestration shall be designed and constructed using debris mitigating materials suchas laminated glass. The glass shall be restrained within the mullions and the mullions shall bedesigned to accept the design level pressures. Curtain wall framing members shall span fromslab to slab and shall not be attached directly to gravity load bearing elements (such ascolumns and shear walls) unless an advanced analysis <strong>of</strong> the load bearing elementdemonstrates it can accept the maximum forces <strong>of</strong> the members framing into it withoutcompromising its load bearing capacity.Ro<strong>of</strong> structure shall be designed to withstand the design level vehicle threat taking intoaccount the presence <strong>of</strong> parapets, the diffusion <strong>of</strong> blast waves, and the spatial extent <strong>of</strong> thero<strong>of</strong> surface.Part I: Basic Solicitation Requirements – Page 58 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Skylights shall be designed in response to the calculated peak pressures and impulsesresulting from the design level vehicle threat. Skylight glass shall be restrained within themullions and the mullions shall be designed to accept the design level pressures.Penthouses enclosing mission-critical equipment shall be designed to resist the design levelvehicle threat and to be consistent with the hardened intakes and exhausts.D. Structural SystemStructural systems shall be constructed to withstand the actual pressures and correspondingimpulses produced by the design level vehicle threat and the design level satchel threat thatmay be delivered to loading docks, mailrooms, //below grade parking garages,// and lobbiesprior to screening. The design shall provide a level <strong>of</strong> protection for which progressivecollapse will not occur; the building damage will be economically repairable and the space inand around damaged area can be used and will be fully functional after cleanup and repairs.E. Building SystemsHVAC systems: locate major mechanical equipment above the ground floor in an area notsubject to flooding. All air intakes shall be located so that they are protected from externalsources <strong>of</strong> contamination. Locate the intakes away from publicly accessible areas, minimizeobstructions near the intakes that might conceal a device, and use intrusion alarm sensors tomonitor the intake areas.Locate all outdoor air intakes a minimum <strong>of</strong> 100 feet [30.48 m] from areas wherevehicles may be stopped with their engines running.Locate all outdoor air intakes a minimum <strong>of</strong> 30 feet [9.14 m] above finish grade or onro<strong>of</strong> away from the ro<strong>of</strong> line.Design air intakes and exhausts to minimize the blast over pressure admitted into criticalspaces and to deny a direct line <strong>of</strong> sight from a vehicle threat located at the stand-<strong>of</strong>f distanceto the critical infrastructure within.Maintain positive pressure in lobbies and entrance areas.Fire protection systems: fire department hose connections located on the exterior <strong>of</strong> a buildingshall be secured in suitable enclosure that limits access to authorized personnel. Coordinatewith the serving fire department.F. Security SystemsSecurity Surveillance Television (SSTV): system shall be provided to monitor buildingentrances, restricted areas, mission critical asset areas, and alarm conditions. SSTV systemshall be used for surveillance and observations <strong>of</strong> defined exterior areas, such as site androadway access points, parking lots, and building perimeter, and interior areas from acentralized police operations room or security control center. The design, installation, and use<strong>of</strong> SSTV cameras shall support the visual identification and surveillance <strong>of</strong> persons, vehicles,assets, incidents, and defined locations.The Intrusion Detection System (IDS) shall include motion detection, glass break, and doorcontact sensors, among other devices. These devices provide alternative methods to detectactual or attempted intrusion into protected areas through the use <strong>of</strong> alarm components,monitoring, and reporting systems. The IDS shall have the capability <strong>of</strong> being integrated withDSPI, PACS, and SSTV systems. All IDS shall meet UL 639 Intrusion Detection Standard.Part I: Basic Solicitation Requirements – Page 59 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]IDS shall be used to monitor the site perimeter, building envelope and entrances, and interiorbuilding areas where access is restricted or controlled.Physical Access Control System (PACS): shall include, but not be limited to: card readers,keypads, biometrics, electromagnetic locks and strikes, and electronic security managementsystem (SMS). PACS devices shall be used for the purpose <strong>of</strong> controlling access andmonitoring building entrances, sensitive areas, mission critical asset areas, and alarmconditions from an access control perspective. This includes maintaining control over definedareas such as site access points, parking lot areas, building perimeter, and interior areas thatare monitored from a centralized SCC. PACS shall be able to be fully integrated with othersecurity subsystems using direct hardwire or computer interface.Electronic Security <strong>Management</strong> System (SMS): The SMS shall allow the configuration <strong>of</strong>an enrollment and badging, alarm monitoring, administrative, asset management, digital videomanagement, intrusion detection, visitor enrollment, remote access level management, andintegrated security workstations or any combination there<strong>of</strong>. Entry control s<strong>of</strong>tware shall allowfor programming <strong>of</strong> the PACS via a CPU. All s<strong>of</strong>tware shall be updated per manufacturer’sinstructions. Network interface devices shall consist <strong>of</strong> all hardware and s<strong>of</strong>tware required toallow for full interface with other security subsystems via a CPU.Duress, Security Phones, and Intercom System (DSPI): The DSPI system is used toprovide security intercommunications for access control, emergency assistance, andidentification <strong>of</strong> locations where persons under duress request a security response. Allcomponents <strong>of</strong> the DSPI shall be fully compatible and shall not require the addition <strong>of</strong> interfaceequipment or s<strong>of</strong>tware upgrades to ensure a fully operational system. DSPI shall be fullyintegrated with other security subsystems.G. Special Areas(1) General Design CriteriaApply the following considerations in the layout and design <strong>of</strong> special areas within theoutpatient clinic.Agent Cashier: The agent cashier shall be located with the transaction window facing acorridor accessible to public and employees, but not opening to a lobby. There shall be noopenings to the exterior <strong>of</strong> the building. The agent cashier space shall be accessed by a doorto a corridor which is accessible only to employees <strong>of</strong> the facility. A duress alarm shall beprovided in a location not visible to customers at the transaction window.Telephone Equipment Room and/or Main Computer Room: The Telephone EquipmentRoom and/or Main Computer Room shall be located not closer than 50 feet [15.24 m] in anydirection to main entrance lobbies, loading docks, and mailrooms, and in no case directlyabove or below such spaces.Emergency Department: Provide direct observation <strong>of</strong> the waiting room from the PoliceOperations Room and direct access. Locate adjacent Police and Security Service OperationsRoom or as close thereto as feasible. Provide separate entrances for ambulatory patients andpatients arriving by ambulance. Provide space for screening <strong>of</strong> pedestrians.Emergency and/or Stand-By Generators: The emergency and stand-by generators andrelated switchgear may be located in a separate structure from the main building or within themain building. The generator room shall not be located at an elevation subject to flooding atPart I: Basic Solicitation Requirements – Page 60 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]any time. The generator room shall not be located closer than 50 feet [15.24 m] <strong>of</strong> a loadingdock/receiving area or mailroom, and shall not be located beneath such facilities. Areawaysand louver openings serving the generator shall not open to the service yard for the loadingdock. Entrances from the exterior shall not open to the loading dock service yard.Mailroom: The mailroom may be located in the main building or in a separate structure on thesite shared with loading dock, storage, and other non-critical functions. Mailrooms within themain building shall be located on an exterior wall. Mailrooms may be located immediatelyadjacent the following areas: service yard, trash containers, loading dock, freight elevators,and non-critical support areas. Mailrooms shall not be located adjacent to or within 50 feet[15.24 m] <strong>of</strong> the following: Security Control Center or Police Command Center, emergency orstand-by generators, UPS, main electrical switchgear, main utility service entrances,emergency egress from the main building, flammable liquids or gas storage, and outdoor airintakes.Exterior entrance doors and frames to mailroom shall be constructed <strong>of</strong> heavy duty hollowmetal and shall be controlled and monitored. When located within the main building, structuralcolumns passing through the mailroom and inspection area and floor slabs above them shallbe structurally hardened to sustain an explosion within the mailroom or inspection area from acharge weight defined in the Life Safety Protected Physical Security Design Manual.Mailboxes, when provided, shall be in a separate room from the mailroom and inspection area,and shall comply with the mounting heights and other regulations <strong>of</strong> the US Postal Service.The mailroom shall be separated from the mailbox room, corridors, and spaces adjoining withreinforced masonry walls and doors <strong>of</strong> hollow metal construction. The mailroom, including theinspection area and the exterior loading area serving the mailroom shall be monitored bySSTV.Air serving the mailroom shall not circulate to other parts <strong>of</strong> the building.Pharmacy: Deliveries to and shipments from pharmacies may be via the main loading dockand service yard. Pharmacies shall not be immediately adjacent the loading dock ormailroom.Police Operations Room and Holding Room: Police operations room shall be located onthe first floor <strong>of</strong> the building adjacent to the highest potential trouble area, such as emergencyor urgent care room, or lobby and shall be located to allow appropriate response anddeployment to respond to a security related event. Holding room shall be located within oradjacent to the police operations room. When the police operations room is adjacent to oropens onto areas occupied by unscreened public, such a lobbies, emergency rooms, andpublic corridors, construction, including partitions from slab to slab, doors, windows, and otheropenings separating the unit from such spaces, shall be 1-hour fire resistive, UL level 3ballistic-resistant. SSTV surveillance shall be provided <strong>of</strong> the entire room through an openingglazed with transparent polycarbonate in a steel frame firmly anchored to the wall.Records Storage: Record storage rooms shall be located not nearer than 50 feet [15.24 m] inany direction from main entrance lobbies, loading docks, and mailrooms and in no casedirectly above or below such spaces.(2) Additional Security RequirementsLessor shall provide the following physical security measures or features for the spaces orareas listed below.Part I: Basic Solicitation Requirements – Page 61 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]SECURITY REQUIREMENTS for SPECIAL AREASLOCATIONAPPLICABLE REQUIREMENTS (X)(See list below table)1 2 3 4 5 6 7 8 9 10 11 12 13 14Canteen Retail Store X O X X X X XCanteen Storage Room X O X X X X XCanteen <strong>Office</strong> X O X X X X O XAgent Cashier X X X X X X XPharmacy and Supply X X X X X X X X X XDrug Storage RoomsPharmacy Dispensing X X X X X XAreasPharmacy Manufacturing X X X X X X XAreaAcquisition & Materiel O X X X X X<strong>Management</strong> (A&MM)(Supply Warehouse)Dental Precious Metal O X O X XStorageInformation Resources X X X X X X<strong>Management</strong> – DHCPMain TelephoneX X X X X XEquipment Room;Computer RoomEmergency Room andTreatment RoomsX X X1: WindowsWindows with sills less than 40 feet [12.19 m] from the ground or the ro<strong>of</strong> <strong>of</strong> a lower abutment,less than 25 feet from windows <strong>of</strong> an adjoining building, and accessible by a building ledgeleading to windows <strong>of</strong> other floor rooms require security mesh screening. Stainless steelsecurity mesh screening shall be equivalent to woven mesh 0.028" wire diameter alloy #304stainless steel, and have a tensile strength <strong>of</strong> 800 pounds per lineal inch. Mesh shall beequivalent to 12 x 12 per inch with main and sub frames <strong>of</strong> 12 gauge carbon steel with bakedenamel finish and internal key locking slide bolts. Security mesh screens are to be installedon inside <strong>of</strong> windows.2: WallsAll walls or partitions for the designated room shall be constructed to resist forced entry.Exterior walls <strong>of</strong> brick or masonry construction shall be acceptable. Metal stud walls shall bereinforced with security mesh to provide equivalent protection.Interior partitions may be solid 4-inch CMU or metal stud with security mesh.Metal lath or plaster base is unacceptable as security mesh. Security mesh shall be flattened,expanded metal manufactured from high strength, low alloy steel and shall conform to ASTMF 1267, Type 11, Class 1, Mill finish. Mesh designation: 3/4 #13F; Mesh Design Size 0.923 x2.10 inch; Mesh Opening Size 0.688 x 1.781 inch; 13 meshes per foot, 74% open area; MeshStrand Width 0.106 inch; Mesh Strand Thickness 0.078 inch; Weight 0.75 pounds per squarePart I: Basic Solicitation Requirements – Page 62 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]foot. Provide manufacturer’s attachment clips and use recommended fasteners to securemesh to wall framing.3: Doors And LocksSolid core wood or hollow steel door construction shall be 1-3/4" thick. Dutch or half doors areunacceptable. Hinge pins on door exterior (unsecured side) shall be non-removable type.Doors shall be set in hollow metal (steel) frames and fitted with mortise lock. All lockingarrangements shall comply with NFPA 101 and shall require no more than one operation fromthe inside (in direction <strong>of</strong> egress) to unlock/unlatch the door regardless <strong>of</strong> the number <strong>of</strong> locksor latches.Mortise lock shall have latch bolt and independent dead bolt (min ¾-inch throw). Latch boltmust be automatically locking on door closure; requiring re-entry to the room with key or lockcombination and allowing egress from the room by use <strong>of</strong> an inside lever. Key outside orthumb turn inside shall retract or project the dead bolt. When dead bolt is projected, insidelever shall simultaneously retract latch bolt and dead bolt. Combinations or keys to locks willbe restricted to service employees and combinations changed immediately on the terminationor reassignment <strong>of</strong> an employee.4: Other Room Access MeansCeiling overhead areas which enable entry into a secure room from an unsecured room mustbe barricaded by the installation <strong>of</strong> a suitable partition or ceiling which deters "up and over"access. Ventilation grills on doors which exceed 96 square inches [620 cm 2 ] in area must bereinforced to prevent their removal from outside the room. All vents, ducts, and similaropenings in excess <strong>of</strong> 96 square inches [620 cm 2 ] that enter or pass through the secure spaceshall be protected with either bars or grills. If one dimension <strong>of</strong> the duct measures less thansix inches [150 mm] or duct is less than 96 square inches [620 cm 2 ], bars are not required;however, all ducts must be treated to provide sufficient sound attenuation. If bars are used,they must be ½-inch [12.7 mm] diameter steel welded vertically and horizontally six (6) inches[150 mm] on center; if grills are used, they must be <strong>of</strong> 9-gauge expanded steel. Openings inconstruction above ceilings or below raised access floors shall be protected as above.5: Motion Intrusion DetectorsAn intrusion detection alarm system which detects entry into the room and which broadcasts alocal alarm <strong>of</strong> sufficient volume to induce an illegal entrant to abandon a burglary attempt.Intrusion detectors must have the following essential features:An internal, automatic charging DC standby power supply and a primary AC power operation.A remote, key operated activation/deactivation switch installed outside the rooms and adjacentto the room entrance door frame.An automatic reset capability following an intrusion detection.A local alarm level <strong>of</strong> 80 dB (min) to 90 dB (max) up to 100 feet [30.48 m] from the protectedroom.An integral capability for the attachment <strong>of</strong> wiring for remote alarm and intrusion indicatorequipment (visual or audio).A low nuisance alarm susceptibility.Part I: Basic Solicitation Requirements – Page 63 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Intrusion detector equipment which operates on the principle <strong>of</strong> narrow beam interception,microwave, or photo electric eye is unacceptable.Installation Notes:A locally sounding alarm should not be installed in a room which is close to a cardiac care orother special treatment area where a loud alarm would have an injurious effect on patients.Intrusion detector alarms will be remotely monitored by a commercial security alarmmonitoring firm, a local police department, or a security <strong>of</strong>fice charged with building security.The remoted alarms will be in addition to locally broadcast alarms in the protected areas.6: Pharmacy Dispensing CounterPartitions and windows <strong>of</strong> pharmacy dispensing counters shall be UL Level 3 ballisticconstruction and 15-minute forced entry construction, including partitions, doors, glazedopenings, teller windows, and transaction trays.7: Agent Cashier CounterPartitions and teller windows facing the public corridor shall be UL Level 3 ballisticconstruction and 15-minute forced entry construction, including partitions, doors, glazedopenings, teller windows, and transaction trays.8: Bulk Drug Storage Safes And VaultsDrugs classified as Schedule I or II controlled substances under the Controlled Substance Act<strong>of</strong> l970 must be stored in safes or vaults which conform to the following specifications://Safes will be GSA class 5 security containers weighing no less than 750 pounds. Dueconsideration shall be applied to the design <strong>of</strong> the floor system's live load capacity.////Lessor shall construct Type I vault for outpatient clinic. Size and location are shown on theconceptual layout in this <strong>SFO</strong>. Vault specifications are as follows:Type I Vault: Enclosures constructed on steel security screen, woven mesh, .047" wirediameter alloy #304 stainless steel, and have a tensile strength <strong>of</strong> 1,600 pounds per linealinch. Mesh 10 x 10 per inch with main frame and subframes <strong>of</strong> 13 gauge alloy #304 stainlesssteel. In rooms with dropped ceilings, the vertical frames and mesh walls must meet theactual ceiling or a security mesh ceiling installed below the false ceiling.//9: Bulk Drug Storage CabinetsSteel cabinet with adjustable shelving and built in locking devices are required for the storage<strong>of</strong> bulk supplies <strong>of</strong> Schedule II to V controlled substances.10: Security Surveillance TVSecurity surveillance TV camera with motion detector feature on cameras and at monitorlocation.11: Special Key ControlRoom door lock keys and day lock combinations, where applicable, are Special Keys and arenot mastered.Part I: Basic Solicitation Requirements – Page 64 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]12: Drug Cabinets//Lessor// //VA// shall provide key locked, all steel cabinets to be firmly anchored in place arerequired for emergency room or treatment room storage <strong>of</strong> small quantities <strong>of</strong> controlledsubstances. Quantities and locations <strong>of</strong> drug cabinets shall be as listed in Schedule B.13: RefrigeratorsVA furnished and installed. //Lessor shall provide refrigerators as listed in Schedule Bequipped with built in lock mechanism when used to store controlled substances (allschedules) and other potentially dangerous drugs and when located outside a locked orattended drug storage room.//14: Medicine CabinetsVA furnished and installed. // Provide secure narcotics locker(s) as listed in Schedule B.//H. Natural Disasters Resistive Design//Lessor shall include the following specific provisions for emergency utility services,emergency site access facilities, and resistive design <strong>of</strong> non-structural building elements.Where local Seismic Code is more stringent, comply with local code. Non-structural buildingelements include all components or systems that are not part <strong>of</strong> the building’s structuralsystem whether inside or outside, above or below grade. Non-structural elements <strong>of</strong> buildingsinclude architectural, elevator and transport, mechanical, plumbing, and electrical elements.//I. Emergency Utilities(1) Electric Power ServicesProvide emergency electric power in accordance with the requirements <strong>of</strong> Paragraph 6.7.8Essential Electrical Systems for Clinics herein.(2) //Natural Gas ServiceIn addition to a manual shut-<strong>of</strong>f valve, provide an earthquake-sensitive automatic safety shut<strong>of</strong>fvalve in the on-site gas supply line serving the outpatient clinic.//J. Emergency Site Access <strong>Facilities</strong>(1) Ground TransportationProvide for emergency access to VA premises from two or more public roads.//Design on-site bridges, retaining walls, culverts, and other road structures, which conducttraffic, to comply with local seismic code requirements.//(2) //Air Transportation////Provide a safe and reliable on-site space for ready access <strong>of</strong> emergency helicopters on aparking area, road, or lawn. Provide an appropriate access for transporting patients andsupplies both ways between the helicopters and outpatient clinic building.//Part I: Basic Solicitation Requirements – Page 65 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]K. Seismic and Natural Disasters Resistive Design <strong>of</strong> Non-Structural BuildingElements(1) DefinitionsNon-structural building elements include all components or systems that are not part <strong>of</strong> thebuilding’s structural system whether inside or outside, above or below grade. Non-structuralelements <strong>of</strong> buildings include:Architectural Elements: Facades that are not part <strong>of</strong> the structural system and its shearresistant elements; cornices, and other architectural projections and parapets that do notfunction structurally; glazing; nonbearing partitions; suspended ceilings; stairs isolated fromthe basic structure; cabinets; bookshelves; medical equipment; and storage racks.Electrical Elements: Normal and emergency power and lighting systems; switchboards,panelboards, and transformers; emergency engine-generator sets and automatic transferswitches; motor controllers; elevator and transport systems; fire alarm systems; andtelecommunication systems.Mechanical Elements: Heating, ventilating, and air-conditioning systems; medical gassystems; plumbing systems; sprinkler systems; pneumatic systems; and mechanical andstructural elements for transport systems, i.e., elevators and dumbwaiters, including hoistingequipment and counterweights.(2) //Earthquake Resistive Design Requirements////Provide restraints, flexibility <strong>of</strong> service connections, and field reinforcements, or acombination <strong>of</strong> those provisions, for earthquake-resistive design provisions for non-structuralelements <strong>of</strong> buildings. Design and detail restraint systems under supervision <strong>of</strong> a pr<strong>of</strong>essionalstructural engineer registered in the state where the project is located. Clearly indicate allspecial seismic details for restraining non-structural elements on the construction drawings.Drawings shall be sealed by the structural engineer.Restraints: Provide bolts, anchors, hangers, braces, and other restraining devices to limitearthquake-generated differential movements between non-structural elements and thebuilding structure. Brace suspended items, including piping, conduit, ducts, and lightingfixtures in both directions to resist swaying and excessive movement.Flexibility: Keep mechanical and electrical systems crossing building expansion or seismicjoints to a minimum, and provide flexibility to allow for earthquake-generated differentialmovements. Where possible, restrict these crossings to lower stories. Where these systemsmust cross such joints, provide flexible joints, expansion loops, or other effective methods <strong>of</strong>incorporating flexibility. Allow for anticipated differential movement for sleeves and openings.Use flexible electrical raceways where connecting components would experience damagingrelative movements.Field Reinforcement: Reinforce all field fabricated non-structural elements <strong>of</strong> buildings andequipment to resist damage from earthquake-generated motions.Architectural Items at Seismic Joints: At seismic joints, detail ceiling and wall constructionto allow movement without damage. Do not cross seismic joints with suspended ceilingsystems with lay-in tiles. Do not assume finishes in the vicinity <strong>of</strong> seismic joints to besacrificial.//Part I: Basic Solicitation Requirements – Page 66 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY](3) //Hurricane and Flood Resistive Design Requirements////Design and construct the outpatient clinic building and utilities to comply with local coderequirements and to provide the following resistive features.Automatic Transport Systems: Provide sump pump pit for portable storm water pump inelevator pit.Air Conditioning Systems: If possible, avoid the installation <strong>of</strong> outdoor equipment such ascooling towers, ro<strong>of</strong> mounted fans, ventilators, and air-conditioning units on the ro<strong>of</strong>. Ifexterior installation is necessary, properly secure equipment to withstand wind forces thatcomply with local codes. If there are no local codes, use wind velocities indicated in ASCE 7-05 or later version if available.//4.3 FIRE PROTECTIONThe Public Buildings Amendment Act (PL 100-678) requires all Federal agencies to follow thelatest editions <strong>of</strong> nationally recognized fire and life safety codes. Lessor shall comply withapplicable provisions <strong>of</strong> the local codes and VA adopted codes and standards(Paragraph 4.2). Where conflicts exist between these standards and local codes, the designershall satisfy the most stringent requirement. Strict compliance to codes and standards ismandatory for new construction.4.3.1 SITE CONSIDERATIONSProvide access for emergency vehicles to buildings and additions. Design roads, fire lanes,and turn-arounds for the weight and turning radius <strong>of</strong> fire apparatus. Consult local firedepartment for fire apparatus requirements. At minimum, one <strong>of</strong> the long sides <strong>of</strong> everybuilding shall be accessible to fire department equipment.Barriers must be placed adjacent to vulnerable perimeter fences, protection for site utilityequipment, at building entrance, and other areas requiring additional protection from vehicles.Parking: Passenger vehicles shall not be parked or permitted to travel closer than 25 feet[7.62 m] to a life-safety-protected VA facility.4.3.2 BUILDING CONSTRUCTIONTypes <strong>of</strong> <strong>Construction</strong>: Base the design on the construction type necessary to comply withcode requirements for the most restrictive occupancy in the building in accordance with NFPA101 and locally adopted codes and standards. Should a conflict exist between NFPA 101requirements and locally adopted codes and standards, the more stringent requirement shallapply.Consider separation distances to adjoining structures or hazards. Protect exterior walls andopenings from exposure as required by Code. Locate combustible structures or structuresthat have combustible ro<strong>of</strong> assemblies a minimum <strong>of</strong> 25 feet [7.62 m] from the exposedbuilding. Shelters or pavilions that are <strong>of</strong> masonry construction shall not be located within10 feet [3 m] <strong>of</strong> any building opening.Part I: Basic Solicitation Requirements – Page 67 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Ro<strong>of</strong> coverings shall be approved or listed by a nationally recognized testing laboratory forcompliance with UL standard 790 and be Class B minimum. Ro<strong>of</strong> deck assemblies shall beFM Class I approved, or UL listed as Fire-Classified.4.3.3 OCCUPANCY TYPEOccupancy classifications are defined in NFPA 101 and as follows:4.3.4 MEANS OF EGRESSAll exits, stairs, corridors, aisles, and passageways that may be used by the Government shallcomply with the latest edition <strong>of</strong> NFPA 101 ("Life Safety Code") and locally adopted codes andstandards for the occupancy classification. Should a conflict exist between NFPA 101requirements and locally adopted codes and standards, the more stringent requirement shallapply. Corridors shall comply as follows:Major corridors shall have a minimum width <strong>of</strong> 8 feet [2.44 m] and departmental corridors shallhave a minimum width <strong>of</strong> 6 feet [1.83 m]. Major and departmental corridors are defined inSECTION 7 below.4.3.5 FIRE PROTECTION IN HAZARDOUS AND HIGH HAZARD AREASHazardous and high hazard areas within the outpatient clinic shall be protected as prescribedin NFPA 101, Life Safety Code and local building codes and ordinances. Areas identified ashigh hazard shall be protected by not less than a minimum 1-hour fire enclosure with C-labeled doors and automatic sprinklers.A. Storage RoomsStorage rooms <strong>of</strong> 50 or more square feet [15.24 sq m] net area shall be considered hazardousareas and comply with appropriate occupancy chapter requirements <strong>of</strong> NFPA 101.Rooms containing medical records storage or moveable-aisle/mobile shelving shall beprovided with automatic sprinkler protection and enclosed with a barrier having a one-hour fireresistance rating.B. Flammable and Combustible StorageFlammable and Combustible Liquid Storage shall comply with NFPA 30. Do not locatelaboratories in basements. Provide adequate space for flammable and combustible liquidstorage cabinets.C. //Compressed Gas/Cryogenic Liquid Storage//Location, construction, and arrangement <strong>of</strong> compressed medical gas storage areas shallcomply with NFPA 99.Bulk oxygen supply systems or storage locations having a total capacity <strong>of</strong> more than20,000 cu feet [566 cu m] <strong>of</strong> oxygen shall comply with NFPA 55.//D. Laboratories//Laboratories using flammable or combustible liquids in buildings with outpatients incapable <strong>of</strong>self-preservation shall comply with NFPA 99. These laboratories shall be enclosed with abarrier having a one-hour fire resistance rating. ////Laboratories using flammable or combustible liquids shall comply with NFPA 45.//Part I: Basic Solicitation Requirements – Page 68 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]4.4 ENVIRONMENTAL4.4.1 INDOOR AIR QUALITYApply requirements <strong>of</strong> the latest version <strong>of</strong> ANSI/ASHRAE Standard 62, Ventilation forAcceptable Indoor Air Quality. This standard affects the way ventilation systems are designedand operated. Provide certification to the Contracting <strong>Office</strong>r that the building is in compliancewith this standard. This certification shall be submitted as part <strong>of</strong> the commissioning process.Refer also to 4.8, SUSTAINABLE DESIGN AND ENERGY EFFICIENCY for indoor air qualitybefore occupancy, and for use <strong>of</strong> low-VOC-emitting materials.Air contaminant levels (e.g., dust, vapor, fumes, and gases) shall not exceed those in 29 CFR1910.1000 and 1910.1001. When actual concentration levels equal or exceed 50% <strong>of</strong> thelevels in 29 CFR 1910, remedial actions shall be initiated. Use <strong>of</strong> evaporative cooling systemswill not be allowed.The Lessor shall control contaminants at the source so that in no instances during facilityoperation shall levels for carbon monoxide (CO), carbon dioxide (CO 2 ), and formaldehyde(HCHO) exceed indicator levels for <strong>of</strong>fice areas <strong>of</strong>: (1) CO – 9 parts per million (ppm) timeweighted average (TWA – 8-hour sample); (2) CO 2 – 1000 ppm (TWA); and (3) HCHO – 0.1ppm (TWA).Materials that are used for interior design including wall and floor treatment shall emit lowamounts <strong>of</strong> Volatile Organic Compounds. Refer to Paragraph 4.8.The Lessor shall promptly investigate indoor air quality (IAQ) complaints submitted through theContracting <strong>Office</strong>r or his designee, as appropriate. The Lessor shall implement necessarycontrols to bring facility into compliance with requirements contained in this documentincluding alteration <strong>of</strong> building ventilating, heating and air conditioning systems, and operatingprocedures (e.g., adjusting air intakes, adjusting air distribution, cleaning and maintainingHVAC, etc.).VA reserves the right to conduct independent IAQ assessments and detailed studies in spaceit occupies, as well as in space serving the VA leased space (e.g., common use areas,mechanical rooms, HVAC systems, etc.). The Lessor shall assist VA in its assessments anddetailed studies by making available information on building operations and Lessor activities,providing access to space for assessment and testing, if required, and implementing correctivemeasures required by the Contracting <strong>Office</strong>r.4.4.2 ASBESTOSMaterials containing asbestos shall not be used. It shall be the responsibility <strong>of</strong> the Lessor tocertify that asbestos-containing materials have not been used in the construction <strong>of</strong> thebuilding to be occupied by VA. Lessor acquisition process for materials used in construction,including, but not limited to, thermal insulation, surfacing material, floor tile, sheet vinyl, andfirepro<strong>of</strong>ing material shall include clauses to specifically exclude asbestos from the materialsbeing used in the building. //For existing buildings, the Lessor shall submit certification signedby an independent Certified Industrial Hygienist that friable asbestos containing materials havebeen removed to the maximum extent feasible.// The foregoing applies to soil in crawl spacecontaining asbestos in levels that are deemed excessive by State and Federal requirements.Lessor is to provide information in the form <strong>of</strong> an asbestos survey conducted in conformanceto AHERA requirements on the location <strong>of</strong> all remaining friable and non-friable asbestos. ThisPart I: Basic Solicitation Requirements – Page 69 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]certification shall be submitted prior to occupancy by the government. The Contracting <strong>Office</strong>rshall review the certification provided by the Lessor. Lessor shall guarantee that all non-friableasbestos that becomes friable due to any reason shall be removed in accordance withapplicable State and Federal requirements.4.4.3 RADON MEASUREMENT AND CORRECTIVE ACTIONRadon levels in space leased to the Government shall not equal or exceed the EnvironmentalProtection Agency (EPA) action level for homes <strong>of</strong> 4 picocuries per liter (pCi/L).The space proposed for lease to the Government, which is in ground contact or closest to theground, shall be measured by the Lessor for radon and the results certified in accordance toEPA procedures. For structures built on a slab (i.e., without a basement) radon levels shall betested on the first floor <strong>of</strong> the structure. Radon detectors shall be placed throughout therequired area to ensure coverage meets EPA and/or State recommended requirements. Inany case, each detector shall cover no more than 2,000 square feet [609.6 sq m] <strong>of</strong> space.Radon shall be measured in accordance with EPA and manufacturer required procedures fora minimum <strong>of</strong> 90 days using either Alpha Track Detectors or Electret Ion Chambers. If 90 daytesting period is not possible, Alpha Track Detectors may be used for a minimum period <strong>of</strong> 2 to4 weeks or Charcoal Canisters or Electret Ion Chambers for a period <strong>of</strong> 2 to 3 days. Ifmeasurements are made for fewer than 90 days, follow-up measurements for a minimum <strong>of</strong>90 days, using either Alpha Track Detectors or Electret Ion Chambers, must be completed. Alaboratory successfully participating in the EPA-sponsored radon measurement pr<strong>of</strong>iciencyprogram shall perform laboratory detector analyses. Quality control/quality assuranceprocedures shall be developed in accordance with industry standards and applied to radontesting results. Provide VA with a copy <strong>of</strong> the lab analysis and actual radon measurements foreach detector used in support <strong>of</strong> the certification.If the space <strong>of</strong>fered for lease to the Government is in a building under construction orproposed for construction, the Lessor shall construct the building to the maximum extentfeasible in such a way to minimize radon intrusion into the building. Lessor shall perform thenecessary radon testing and submit a certification to the Contracting <strong>Office</strong>r within 30 daysafter the test is completed, but not later than 150 days after VA occupies the space. If radonmeasurements at or above 4 pCi/L are detected, the Lessor shall promptly initiate correctiveaction to reduce the level to below 4 pCi/L. If the Lessor does not affect corrective action, thisis sufficient reason by itself for VA to void or not enter into the lease agreement.VA reserves the right to measure radon in the space it leases at any time during the term <strong>of</strong>the lease. If radon measurements at or above 4 pCi/L are detected, the Lessor shall promptlyinitiate corrective action to reduce the level to below 4 pCi/L. If radon at or above 4 pCi/L isdetected, the Lessor shall restrict the use <strong>of</strong> the area and provide comparable temporaryspace for the tenants until the corrective action is completed. Follow-up measurements shallbe conducted by the Lessor to determine the effectiveness <strong>of</strong> the corrective action. TheLessor at no additional cost to VA shall provide all corrective actions, tenant relocation, andfollow-up measurements. The Lessor shall provide VA with prior written notice <strong>of</strong> anyproposed corrective action or tenant relocation.4.4.4 RADON IN WATERTwo water samples constituting a sampling pair shall be taken from the same location forquality control. They shall be obtained inside the building and as near the non-public watersource as is practical, in accordance with EPA's Radon in Water Sampling Program Manual.Part I: Basic Solicitation Requirements – Page 70 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]An analysis <strong>of</strong> water samples for radon must be performed by a laboratory that uses theanalytical procedures as described in EPA's Two Test Procedures For Radon in DrinkingWater.The Lessor shall perform the necessary radon testing and submit a lab test and a certificationto the Contracting <strong>Office</strong>r before VA occupies the space.If the EPA action level is reached or exceeded, the Lessor shall institute abatement methodswhich reduce the radon to below the EPA action level, such as aeration, prior to occupancy byVA.4.4.5 POTABLE WATER QUALITYPotable water provided to VA from municipal or community water systems shall meet EPAand/or state standards for contaminants. //For existing buildings, Lessor will repair or replaceexisting plumbing that is shown to increase the contaminants in municipal or communitysupplied water to levels that exceed EPA and/or state requirements.//If potable water does not meet EPA and/or state standards, Lessor shall take action necessaryto reduce contamination to acceptable levels. Lessor shall test potable water periodically toensure that it continues to meet EPA and state standards. Lessor shall provide bottled waterat his/her expense at any time contaminant levels exceed EPA and/or state requirements. Ifpotable water does not meet EPA and/or state standards, Lessor shall take action necessaryto reduce contamination to acceptable levels.//Potable water provided to VA from on site wells or other non-municipal sources shall meetminimal EPA and/or state standards for contaminants.//4.5 SPECIAL ENVIRONMENTAL REQUIREMENTSAny leased project over 75,000 GSF shall comply with the National Environmental Policy Act<strong>of</strong> 1969. Sites with proposed buildings <strong>of</strong> less than 75,000 GSF Must acquire CERCLA andSHPO clearance.If required, special building equipment to treat and exhaust to the atmosphere toxic gasesproduced by the agency program equipment shall be provided by Lessor. All suchinstallations shall comply with appropriate OSHA, EPA or related regulations <strong>of</strong> the localcommunity. Lessor shall obtain all necessary permits for construction and operation. Inaddition, provide up to 100% outside air for clinical laboratories and other areas designated inSection 6 Mechanical requirements.4.6 ACCESSIBILITY STANDARDSThe design, construction, and alteration <strong>of</strong> facilities shall comply with local codes andordinances. In addition, all VA facilities must comply with the Architectural Barriers ActAccessibility Standards (ABA-AS) as adopted by GSA and VA Program Guide PG-18-13,"Barrier Free Design Guide."The ABA-AS consists <strong>of</strong> Appendices C and D to 36 CFR Part 1191 (ABA Chapters 1 and 2,and Chapters 3 to 10) and is available from United States Access Board http://www.accessboard.gov/.Part I: Basic Solicitation Requirements – Page 71 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]VA Barrier Free Design Guide PG18-13 is available from VA Technical Information Library athttp://www.cfm.va.gov/til/dGuide/barrfree.doc.The Offeror shall comply with the stricter <strong>of</strong> these standards for each requirement asdetermined by the Government. Offerors are cautioned that compliance with ADA doesnot assure compliance with PG-18-13. The following list includes some <strong>of</strong> the requirementsfrom the "Barrier Free Design Guide" that typically exceed ADA or local requirements. Themore stringent requirement shall be followed.VA Accessibility Standards from PG-18-13Paragraph4.1.1(5)(e)(i)Description <strong>of</strong> Requirement3% <strong>of</strong> total parking spaces shall be accessible4.3.4 5’-0" minimum width for accessible routes4.3.7 1:33 (3%) maximum slope for accessible routes, including parkingspaces1:50 minimum gradient for walk requiring rest areas6’-0" x 6’-0" minimum size <strong>of</strong> level platform at doors4.5.3 Carpet cushion or padding is not permitted4.6.3 5’-0" access aisle required both sides <strong>of</strong> accessible parking spaces4.7.3 4’-0" minimum width for curb ramps4.8 Requirements for ramps:1:20 maximum slope40-foot max length for slopes between 1:33 and 1:2435-foot max length for slopes to 1:204’-0" minimum clear width6’-0" x 6’-0" minimum landing where doors swing into landing4.9.4(5) 34" handrail height (not a range <strong>of</strong> heights)4.10 4’-0" minimum elevator door widthDouble set <strong>of</strong> handrails required: 3" x 3/8" with centerlines at 30" and42" above car floor8’-0" x 6’-0" minimum passenger elevator platform size4.13 2’-10" (34") minimum clear opening4.17 Toilet Stalls:5’6" x 6’-0" minimum accessible stall sizePart I: Basic Solicitation Requirements – Page 72 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]VA Accessibility Standards from PG-18-13ParagraphDescription <strong>of</strong> Requirement3’-6" x 6’-0" minimum size "front transfer" stallGrab bars are required in all stalls (not just accessible stalls)4.22 3’-0" (36") minimum width <strong>of</strong> toilet room entrance doors5.0 Cafeterias:2’-3" (25") minimum knee clearance dimension, and2’-5" (27") for minimum 5-percent <strong>of</strong> tables40 to 48" range for cutlery and supply height4.7 OSHA REQUIREMENTSThe Lessor agrees to comply with all Occupational Safety & Health Administration (OSHA)Safety and Health Standards located in 29 CFR.4.8 SUSTAINABLE DESIGN AND ENERGY EFFICIENCY4.8.1 LEED® SILVER EQUIVALENCYDemonstrable LEED® Silver equivalency is required. Lessor shall provide documentation thatthe design and construction <strong>of</strong> facilities meets this goal. From the entirety <strong>of</strong> available LEED®Credits, certain credits are mandatory. The Lessor shall supplement the mandatory creditswith other credits chosen to accomplish sufficient credits for LEED® Silver equivalency. Thelatest version <strong>of</strong> LEED® available shall be used. The mandatory credits (based on LEED® 3)are:Water Efficiency: Credit 1 Water Efficient Landscaping, Reduce By 50%Energy & Atmosphere: Credit 3 Enhanced CommissioningMaterials and Resources: Credit 5 Regional Materials, 20% <strong>of</strong> MaterialsIndoor Environmental Quality: Credit 2 Increased VentilationIndoor Environmental Quality: Credit 3.2 <strong>Construction</strong> IAQ <strong>Management</strong> Plan – BeforeOccupancyInnovation & Design:Credit 2 LEED Accredited Pr<strong>of</strong>essionalLEED® prerequisites necessary to obtain the required credits are also required. Theseinclude:Water EfficiencyEnergy & Atmosphere:Materials and Resources:Indoor Environmental Quality:WEp1, Water Use ReductionEAp1, Fundamental Commissioning <strong>of</strong> Building EnergySystems; EAp2, Minimum Energy Performance; and PR3,Fundamental Refrigerant <strong>Management</strong>MRp1, Storage and Collection <strong>of</strong> RecyclablesEQp1, Minimum Indoor Air Quality Performance; EQp2,Environmental Tobacco Smoke (ETS) ControlPart I: Basic Solicitation Requirements – Page 73 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]4.8.2 STRATEGIESDesign and construction <strong>of</strong> facilities must meet Federal Mandates for sustainability and energyefficiency.The Lessor shall employ the following strategies.A. Employ Integrated Design Principles(1) Integrated DesignUse a collaborative, integrated planning and design process that initiates and maintains anintegrated project team in all stages <strong>of</strong> a project's planning and delivery.Establish performance goals for siting, energy, water, materials, and indoor environmentalquality along with other comprehensive design goals and ensure incorporation <strong>of</strong> these goalsthroughout the design and lifecycle <strong>of</strong> the building. Consider all stages <strong>of</strong> the building'slifecycle, including deconstruction.(2) CommissioningEmploy commissioning practices tailored to the size and complexity <strong>of</strong> the building and itssystem components in order to verify performance <strong>of</strong> building components and systems andhelp ensure that design requirements are met. This should include an experiencedcommissioning provider, inclusion <strong>of</strong> commissioning requirements in construction documents,a commissioning plan, verification <strong>of</strong> the installation and performance <strong>of</strong> systems to becommissioned, and a commissioning report. The systems to be commissioned include activeand passive HVAC equipment and controls, plumbing systems, lighting and daylightingcontrols, domestic hot water systems, and onsite renewable energy systems.Plumbing systems shall also be integrated into the commissioning plan. The commissioningplan shall define pressure test procedures for all pipe systems, shower or bathroom basinleakage tests, plumbing fixture carrier installation, plumbing fixture flow rate adjustment,system chlorination and flush, Legionella disinfection, booster pump package, backflowprevention devices tested by a third party and reports included in the final commissioningreport, thermostatic mixing valves, vacuum system, medical air system, oral evacuationsystem, dental compressed air system, natural gas and fuel system, and special watersystems.B. Optimize Energy Performance(1) Energy EfficiencyEstablish a whole building performance target that takes into account the intended use,occupancy, operations, plug loads, other energy demands, and design to earn the EnergyStar® targets for new construction and major renovation where applicable. For newconstruction, reduce the energy use by 30% compared to the baseline building performancerating per the American Society <strong>of</strong> Heating, Refrigerating and Air-Conditioning Engineers, Inc.,(ASHRAE) and the Illuminating Engineering Society <strong>of</strong> North America (IESNA) Standard 90.1-2007, Energy Standard for Buildings Except Low-Rise Residential. If available, use EnergyStar and FEMP-designated Energy Efficient Products.Per the Energy Independence and Security Act (EISA) Section 523, meet at least 30% <strong>of</strong> thehot water demand through the installation <strong>of</strong> solar hot water heaters, when life-cycle costeffective.Part I: Basic Solicitation Requirements – Page 74 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY](2) Measurement and VerificationPer the Energy Policy Act <strong>of</strong> 2005 (EPAct) Section 103, install building level utility meters innew major construction and renovation projects to track and continuously optimizeperformance. Per EISA Section 434, include meters for natural gas and steam, whereappropriate.Compare actual performance data from the first year <strong>of</strong> operation with the energy designtarget. After one year <strong>of</strong> occupancy, measure all new major installations using the EnergyStar® Portfolio Manager for building and space types covered by Energy Star®.Annually provide data to VA.C. Protect and Conserve Water(1) Indoor WaterEmploy strategies that in aggregate use a minimum <strong>of</strong> 20% less potable water than the indoorwater use baseline calculated for the building, after meeting the EPAct 1992, UniformPlumbing Codes 2006, and the International Plumbing Codes 2006 fixture performancerequirements. The installation <strong>of</strong> water meters is encouraged to allow for the management <strong>of</strong>water use during occupancy.(2) Outdoor WaterUse water efficient landscape and irrigation strategies, including water reuse and recycling, toreduce outdoor potable water consumption by a minimum <strong>of</strong> 50% over that consumed byconventional means (plant species and plant densities). The installation <strong>of</strong> water meters forlocations with significant outdoor water use is encouraged.Employ design and construction strategies that reduce storm water run<strong>of</strong>f and polluted sitewater run<strong>of</strong>f. Per EISA Section 438, to the maximum extent feasible, maintain or restore thepredevelopment hydrology <strong>of</strong> the site with regard to temperature, rate, volume, and duration <strong>of</strong>flow, using site planning, design, construction, and maintenance strategies.(3) Process WaterPer the Energy Policy Act <strong>of</strong> 2005 Section 109, when potable water is used to improve abuilding’s energy efficiency, deploy life-cycle cost-effective water conservation measures.(4) Water-Efficient ProductsUse EPA’s WaterSense-labeled products or other water conserving products. Chooseirrigation contractors who are certified through a WaterSense-labeled program.D. Enhance Indoor Environmental Quality(1) Ventilation and Thermal ComfortMeet ASHRAE Standard 55-2004, Thermal Environmental Conditions for Human Occupancy,including continuous humidity control within established ranges per climate zone, andASHRAE Standard 62.1-2007, Ventilation for Acceptable Indoor Air Quality.(2) Moisture ControlEstablish and implement a moisture control strategy for controlling moisture flows andcondensation to prevent building damage and mold contamination.Part I: Basic Solicitation Requirements – Page 75 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY](3) DaylightingAchieve a minimum <strong>of</strong> daylight factor <strong>of</strong> 2% (excluding all direct sunlight penetration) in 75% <strong>of</strong>all space occupied for critical visual tasks. Provide automatic dimming controls or accessiblemanual lighting controls, and appropriate glare control.(4) Low-Emitting MaterialsSpecify materials and products with low pollutant emissions, including adhesives, sealants,paints, carpet systems, and furnishings.(5) Protect Indoor Air Quality During <strong>Construction</strong>Follow the recommended approach <strong>of</strong> the Sheet Metal and Air Conditioning Contractor'sNational Association Indoor Air Quality Guidelines for Occupied Buildings under <strong>Construction</strong>,1995. After construction and prior to occupancy, conduct a minimum 72-hour flush-out withmaximum outdoor air consistent with achieving relative humidity no greater than 60%. Afteroccupancy, continue flush-out as necessary to minimize exposure to contaminants from newbuilding materials. Prohibit smoking within the building and within 25 feet [7.62 m] <strong>of</strong> allbuilding main entrances and building ventilation intakes during building occupancy.E. Reduce Environmental Impact <strong>of</strong> Materials(1) Recycled ContentFor EPA-designated products, use products meeting or exceeding EPA's recycled contentrecommendations. For other products, use materials with recycled content such that the sum<strong>of</strong> postconsumer recycled content plus one-half <strong>of</strong> the pre-consumer content constitutes atleast 10% (based on cost) <strong>of</strong> the total value <strong>of</strong> the materials in the project. If EPA-designatedproducts meet performance requirements and are available at a reasonable cost, a preferencefor purchasing them should be included in all solicitations relevant to construction, operation,maintenance <strong>of</strong>, or use in the building.(2) Biobased ContentFor USDA-designated products, use products meeting or exceeding USDA's biobased contentrecommendations. For other products, use biobased products made from rapidly renewableresources and certified sustainable wood products. If these designated products meetperformance requirements and are available at a reasonable cost, a preference for purchasingthem should be included in all solicitations relevant to construction, operation, maintenance <strong>of</strong>,or use in the building.(3) Environmentally Preferable ProductsUse products, such as low-emitting materials or products containing no toxic metals, that havea lesser or reduced effect on human health and the environment when compared withcompeting products or services that serve the same purpose.(4) <strong>Construction</strong> Waste and Materials <strong>Management</strong>During a project's planning stage, identify local recycling and salvage operations that couldprocess site-related construction and demolition materials. Program the design to recycle orsalvage at least 50% <strong>of</strong> the non-hazardous construction, demolition, and land clearingmaterials, excluding soil, where markets or onsite recycling opportunities exist. Providesalvage, reuse, and recycling services for waste generated from major renovations, wheremarkets or onsite recycling opportunities exist.(5) Ozone Depleting CompoundsEliminate the use <strong>of</strong> ozone depleting compounds during and after construction wherealternative environmentally preferable products are available, consistent with either thePart I: Basic Solicitation Requirements – Page 76 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Montreal Protocol and Title VI <strong>of</strong> the Clean Air Act Amendments <strong>of</strong> 1990, or equivalent overallair quality benefits that take into account life-cycle impacts.Part I: Basic Solicitation Requirements – Page 77 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]SECTION 5 SITE DESIGN CRITERIA5.1 GENERALA licensed Landscape Architect or Civil Engineer shall develop the site design. A LandscapeArchitect, licensed if state registration exists, shall develop the landscape planting plans.Design <strong>of</strong> site elements shall comply with accessibility standards and in accordance withParagraph 4.6 <strong>of</strong> this solicitation.The Lessor shall obtain Topographic/Landscape, Electrical and Telecommunications, toinclude telephone, data, cable television and special systems; Civil/Mechanical; and SoilSurveys; and geotechnical reports. The survey limits shall include a sufficient area to coverthe complete project including sufficient <strong>of</strong>fsite locations <strong>of</strong> existing utilities, i.e., water, sewer,gas, electric and telecommunications. Refer all vertical elevations to permanent benchmarksbased on actual geodetic datum (not assumed datum).Comply with applicable Federal, State, and municipal laws, regulations, and permitsconcerning design and construction controls for environmental protection <strong>of</strong> aesthetics, air,water, and land. All the following regulatory categories apply:Storm water permits, e.g., National Pollutant Discharge Elimination System (NPDES)permit programPollution control and solid waste disposalErosion control and protection <strong>of</strong> land resourcesProtection <strong>of</strong> landscapeProtection <strong>of</strong> water resources, wetlands, and areas preserved for wildlifeEnsure that the design mitigates any adverse environmental impacts. Ensure all the following:Surface water, during and after construction, will not adversely impact the site orareas downstream from the site.Grading, seeding, erosion control measures, and storm sewers are used to avoidthe above.Air and noise pollution is minimized.Destruction <strong>of</strong> land resources is minimized. Interference with the normal function <strong>of</strong> the surrounding community duringconstruction is minimized.5.2 SITE DEVELOPMENTUse originality and imaginative design between site and structures, vehicular and pedestriancirculation, visual elements, and open and screened area. Produce a plan that has bothfunctional and aesthetic relationships.Part I: Basic Solicitation Requirements – Page 78 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Develop the Site based on //an American Land Title Association (A.L.T.A ) Survey// //a Results<strong>of</strong> Survey// using a title report current within 90 days. Consider impacts to site encumbrancessuch as drainage, rock outcroppings, existing utilities, utility easements, abrupt changes intopography, and protected or mature salvageable vegetation.5.2.1 STORM WATERConsider impacts on existing natural and man-made storm water drainage patterns andsystems. VA is committed to the control <strong>of</strong> storm water by the Federal Water Pollution ControlAct, the Federal Flood Disaster Protection Act, and other Environmental Protection Agency(EPA) regulations that are implemented by Federal, State, and municipal jurisdictions.Provide a Hydrology and Hydraulics analysis and report in support <strong>of</strong> the proposed design.5.2.2 CIRCULATIONProvide separate circulation systems for vehicular service and patient/visitor traffic.Provide a circular driveway to the building drop-<strong>of</strong>f with access to the parking areas. Thedrop-<strong>of</strong>f shall have canopy cover designed to accommodate public bus and shuttle services.Design patient exterior areas that are conveniently accessible from the building withoutvehicular crossings and are oriented to the most favorable site climatic conditions.5.2.3 LOCATION OF BUILDING AND EQUIPMENTEnsure that the building property line setbacks are consistent with adjacent structures andlocal codes.When locating the proposed building, structures, and equipment, consider topography,adjacent facilities, utility access requirements, environmental impacts, and future developmentto produce a design that is functional and aesthetically successful.Provide landscape planting, grading, architectural screening, or fencing <strong>of</strong> exterior utility,mechanical, and electrical equipment for patient and personnel protection.5.2.4 PATIENT USE AREASDesign patient exterior areas that are conveniently accessible from the building withoutvehicular crossings and are oriented to the most favorable site climatic conditions.5.2.5 GRADING DESIGNCoordinate surface grades with architectural, structural, and mechanical design to provideproper surface drainage.Consult soil classification data in the subsurface investigation (geotechnical report) in support<strong>of</strong> drainage concepts proposed as part <strong>of</strong> the Hydraulics and Hydrology analysis.Use contours at a maximum interval <strong>of</strong> 1 foot [0.3 m] to show grading <strong>of</strong> the entire project site.Utilize spot elevations as control points.Show any temporary (construction period) or permanent erosion control.Part I: Basic Solicitation Requirements – Page 79 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Condition Maximum Slope Minimum Slope PreferredLawns 25% 4:1a 2% 50:1 2- 10%Turf athletic area 2% 50:1 0.5% 200:1 1%Berms and mounds 20% 5:1 5% 20:1Mowed slopes 25% 4:1a 20%Planted slopes and beds 10% 10:1 0.5% 200:1 3-5%bRoad crown 3% 33.3:1 2% 50:1 2.5%Roads, longitudinal* 20% 5:1 0.5% 200:1 1-10%Walks, longitudinal 10% 10:1 0.5% 200:1 1-5%Parking, longitudinal 5% 20:1 0.25% 400:1 2-3%a. The maximum slope for mowing machinery is 25%.b. Slopes over 6% should have erosion protection.c. Accessible routes used by people with disabilities shall conform to the criteria <strong>of</strong>Paragraph 2.4 <strong>of</strong> this <strong>SFO</strong>.* Payload is drastically reduced on heavy trucks sustaining grades over 3%. Idealmaximum sustained grade for safe operation <strong>of</strong> trucks and automobiles is 6%. On roadssubject to frequent icing and winter conditions, the maximum sustained grade is 5%.General: Provide complete dimensioned layouts for vehicular and pedestrian pavement,structures, and other components <strong>of</strong> the site and landscape design. Establish control for thelayout by a base control line with dimensions from this line. Small scope projects may useproperty lines for control. Larger projects require coordinates on a grid system.5.2.6 DESIGN OF VEHICULAR AND PEDESTRIAN PAVEMENTDesign the pavement to reflect topography, soils, climate, local materials, function, and otherrequirements and specific situations. The Geotechnical Report shall address and recommendground preparation and pavement section design for the site.When motorcycle parking is provided, construct designated area <strong>of</strong> non-reinforced concrete.A. Pavement <strong>Construction</strong>Design pavement sections <strong>of</strong> all roads, service areas, fire apparatus vehicle accessibilityareas, and parking areas for the maximum anticipated traffic loads and existing soil conditions.Construct service areas for truck dock, bulk oxygen storage, loading docks, utility buildings,and similar facilities <strong>of</strong> reinforced concrete.Principal roads and primary service roads shall include 12’-0" travel lanes for two-way traffic(24'-0" wide between faces <strong>of</strong> curbs). Secondary service roads shall be 12'-0" between faces<strong>of</strong> curbs. Consider two-way traffic lanes where possible. One-way traffic plans shall have aminimum width <strong>of</strong> 12’-0".Part I: Basic Solicitation Requirements – Page 80 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]B. Curbs and GutterDesign all roads with integral concrete curbs and gutters per local standards andspecifications. Substitute free-standing or extruded curbs only when justified.(1) Curb RadiiThe radii <strong>of</strong> curbs at road intersections should be 30'-0" preferred, 25'-0" minimum.(2) Curb Access Ramps (Curb Cuts)Provide curb ramps to accommodate people with disabilities as well as lawnmowers.C. Pavement Marking and SigningProvide locations and details <strong>of</strong> pavement striping and signing for parking, roadways,crosswalks, accessible parking and routes, and other special areas.D. Pedestrian Pavement <strong>Construction</strong>Design walkways to provide clearly-defined, unobstructed, direct routes through the site,interconnecting site and building entryways, curb ramps, parking areas, pedestrianlandscaped features, such as open area plazas, courts, atriums, and other site elements.Construct walks <strong>of</strong> concrete. Reinforce the concrete pavement if subbase conditions warrant.Where pedestrian and vehicular pavements meet, thicken the subbase material.Pedestrian wearing course material may be rigid unit pavers (bricks, stone sets, concreteunits, large paving slabs, etc.). To facilitate use by people with disabilities, design a rigid base<strong>of</strong> concrete or asphaltic concrete beneath pavers.Walks should be at least 60" wide, except 96" minimum where abutting parking stalls.Design walks to accommodate people with disabilities. Eliminate steps unless unavoidable.5.2.7 ENTRANCES TO BUILDINGCoordinate work at entrances to buildings based on the requirements in the ArchitecturalCriteria. Particular reference is made to complying with vertical clearances <strong>of</strong> buildings andcanopies over roadways and vehicular access areas// and snow melting requirements atspecific entrances//.Provide access for ambulance entry.5.2.8 TRUCK DOCKDesign adequate space for truck maneuverability and parking <strong>of</strong> facility equipment, includingtrash dumpsters. Provide wheel path diagram to support turning movements <strong>of</strong> facility parkingequipment, delivery, and waste removal vehicles.5.2.9 PARKING FACILITIESDevelop sufficient new parking so that the total number <strong>of</strong> facility spaces will be the greater <strong>of</strong>[____] spaces, or as required by local codes. Provide [____] parking spaces for physicallydisabled people (handicapped) based on 3% <strong>of</strong> total provided spaces <strong>of</strong> which [_____] are vanaccessible spaces based on every 6 or fraction <strong>of</strong> 6 <strong>of</strong> provided accessible parking spaces.Locate these parking spaces convenient to an entrance accessible by physically disabledpeople.Part I: Basic Solicitation Requirements – Page 81 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Provide a parking tabulation on the contract drawings indicating the total number <strong>of</strong> VA facilityparking spaces with subtotals for standard spaces, accessible spaces, motorcycle spaces,and van accessible spaces. Locate accessible parking spaces convenient to an accessiblebuilding entrance.Provide parking tabulations for motorcycle parking on the contract drawings. Indicate the totalnumber <strong>of</strong> spaces provided, using a ratio <strong>of</strong> one parking space for every 60 auto spaces.Motorcycle parking spaces shall be 4.5 feet [1.37 m] wide x 8 feet [2.44 m] long.Reference Paragraph 4.3.1 for Parking Site Security Considerations.Parking at angles other than 90 degrees may be used only when justifiable. Contracting<strong>Office</strong>r approval is required for deviation. Acceptable dimensions for 90 degrees parkingangle are as follows.If cars overhang curbs onboth sidesIf cars overhang curbs on onesideIf cars will not overhang eithercurb or will be parked in thecenter bumper to bumperAccessible SpacesAccessible Van SpacesMINIMUM BAYWIDTH60'-0"59'-0"58'-0"62'-6"61'-6"60'-6"65'-0"64'-0"63'-0"MINIMUM STALLWIDTH8'-6"8'-9"9'-0"8'-6"8'-9"9'-0"8'-6"8'-9"9'-0"8’-0" x 20’-0" w/ 5’-0"access aisle on bothsides8’-0" x 20’-0" w/ 8’-0"access aislePatient and Visitor spaces shall be 9’-0" minimum width, unless the Contracting <strong>Office</strong>rapproves deviation.5.2.10 EQUIPMENT PADSLocate utility transformers, cooling towers, generators, generator fuel tanks, gaseous tankstorage, and other equipment pads away from patient and visitor entries and outdoor activityareas, preferably adjacent to service area. To prevent injury to patients and personnel,enclose pad area with chain link fencing. Barriers and fencing shall comply with therequirements <strong>of</strong> the serving electric utility, where applicable.//Mobile MRI/CT Scanner Truck ProvisionsLessor shall provide the following provisions for mobile MRI/CT Scanner Truck:Lessor shall furnish a dedicated five-wire 480V, 3-phase wye connection with neutral andground, 150 Amp circuit to supply power to mobile MRI/CT scanner trucks at the MRI padshown on the site plan. The safety disconnect switch shall have lock-on provisions, which willallow the switch to be locked in the "ON" position. The disconnect switch shall also have lock<strong>of</strong>fprovisions. Provide safety disconnect in electrical circuit, per code, on exterior <strong>of</strong> buildingPart I: Basic Solicitation Requirements – Page 82 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]for MRI/CT. Electrical feed shall terminate on exterior <strong>of</strong> building at a //Russellstoll connectorrated for service required// //[____]// receptacle, in a weatherpro<strong>of</strong> box. [Insert receptacleconfiguration here] The bottom <strong>of</strong> the receptacle shall be a minimum <strong>of</strong> 3 feet above grade.The disconnect switch, receptacle, and telecommunications jacks shall be mounted onconcrete posts with strut framing adjacent to the MRI concrete pad.Lessor shall furnish a weatherpro<strong>of</strong> box for telecommunications located adjacent to powerreceptacle. Conduit shall extend to interior distribution system in the building. Install three (3)exterior telecommunications jacks.Truck pad shall be Portland cement concrete [ insert size here or show on conceptual siteplan] Design pavement section for loading in accordance with criteria in Paragraph 5.2.6. Ifreinforcement <strong>of</strong> concrete is required, use only non-ferrous reinforcement materials.Variations in pad levelness shall not exceed 1/8-inch in 10’-0".Provide the following plumbing provisions in two in-ground boxes adjacent to the truck pad.One in-ground box shall be for water supply connections and one in-ground box shall be forsanitary wastewater connection:Provide a hose bib and backflow preventer, connected to a cold water supply line, forconnection <strong>of</strong> a ¾-inch hose.Provide ¾-inch female connector and backflow preventer, connected to a cold water supplyline, for connection <strong>of</strong> a ¾-inch I.P.S. male threaded hose connector. Size line to provide 5gallons per minute at 45-60 PSI. Provide an adjustable pressure regulator with gauge toensure that pressure does not exceed 60 PSI. Water intake equipment will be protected withphysical hardware equipment to provide preclusion <strong>of</strong> entry or introduction <strong>of</strong> foreign materialsand also provide indication <strong>of</strong> tampering. Intake facilities above ground will provide physicalbarriers to preclude entry and tampering <strong>of</strong> equipment.Provide 1½-inch female threaded connector, connected to the sanitary wastewater drainagesystem, for connection <strong>of</strong> a 1½-inch male threaded hose connection.Provide an accessible sidewalk from an exterior door <strong>of</strong> the outpatient clinic to the MRI pad.Provide a canopy for the walkway from the clinic to the MRI pad. The canopy shall complywith criteria in SECTION 5 and SECTION 6.Extend panic (duress) alarm system to MRI pad. Provide connection for one (1) panic buttonin MRI enclosure, connected to main panic (duress) alarm panel.//5.3 LANDSCAPING DESIGNIntegrate the landscape planting design with the overall design <strong>of</strong> the site. The landscapeplanting shall compliment the architecture, preserve designated site features, facilitate waterharvesting, facilitate vehicular and pedestrian access, create open areas and vegetativescreens, and consist <strong>of</strong> plant material that promotes sustainable designs.Select plants that are indigenous to the area, require little maintenance, and are disease andinsect resistant. Select plant material that is nursery propagated from sources as close aspracticable to the project area, that are indigenous to the area, locally available, lowmaintenance, and disease and insect resistant. Plant materials shall conform to thePart I: Basic Solicitation Requirements – Page 83 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]standardized system <strong>of</strong> the American Association <strong>of</strong> Nurserymen, Inc. current AmericanStandards for Nursery Stock, ANSI Z60.1.Do not select plants that are poisonous, highly aromatic, irritating, or thorny. In parking andpedestrian areas avoid plants that drop fruit or sap. Locate plants so they do not interfere withdriver or pedestrian visibility, circulation, and safety.Plant bed outlines curvature shall have minimum radii <strong>of</strong> 3 feet [0.92 m]. Design lawn areas t<strong>of</strong>acilitate maintenance.Provide metallic edging or concrete curbs around shrub beds (essential where Bermuda orsimilar grasses are grown).Utilize ground cover on slopes steeper than 3:1, i.e., 3 feet to 1 foot.5.4 SITE AMENITIES5.4.1 FLAGPOLEThe Lessor shall provide //a flagpole at a location// //flagpoles at locations// to be approved bythe Contracting <strong>Office</strong>r. //Flagpole// //Flagpoles// must extend at least 30 feet above theground and shall be equipped with rope and hardware //for two flags// //one flag each//. TheGovernment will provide the flags. This requirement will be waived if determined inappropriateby the Government. Exterior lighting (two each light fixtures spaced a minimum <strong>of</strong> 20 feetapart, mounted on the building or at grade) shall be provided to illuminate the flags at night.Automatic switching for light fixtures shall be provided.5.4.2 SMOKING SHELTERSAn exterior structure <strong>of</strong> approximately 150 square feet [45.72 sq m] must be provided near one<strong>of</strong> the outside doors to the outpatient clinic building for the purpose <strong>of</strong> providing shelter forpatients, visitors, volunteers, and employees who wish to smoke. The structure shall be builtnear the side or rear <strong>of</strong> the building away from and out <strong>of</strong> sight <strong>of</strong> the main clinic entrance.The smoking shelter shall be architecturally compatible with the main structure. The sheltermust be at least 50 feet [15.24 m] from any building entrance. The structure must beaccessible to disabled persons as specified in SECTION 4 <strong>of</strong> the Basic Solicitation. Thestructure must be heated, air conditioned, and equipped with a ventilation system that meetsrequirements <strong>of</strong> this Solicitation. The ventilation system must have a discharge above the ro<strong>of</strong>level <strong>of</strong> the clinic building that is directed away from the clinic entrance or other possible clinicintakes. The smoking shelter shall be protected with an automatic fire sprinkler system.Provide suitable lighting for smoking shelter; control with the other site lighting.5.4.3 CANOPIES AND COVERED WALKWAYSThe walkway connecting the smoking shelter and the nearest building entry shall be coveredwith a solid ro<strong>of</strong> structure or canopy. //[Insert other covered walks or canopies asnecessary.]// Design <strong>of</strong> the covered walk shall be integrated with the building structure andarchitecture. Coordinate site lighting with walkways. Provide fixtures below canopies andcovered walks where necessary to maintain illumination levels for exterior walkways.Part I: Basic Solicitation Requirements – Page 84 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]5.4.4 EXTERIOR ACTIVITY AREAS AND YARDSProvide //secured// exterior patio or yard areas for outdoor activities and dining as shown onthe conceptual plans. Outdoor areas shall be designed with a diversity <strong>of</strong> landscape andhardscape elements to create an environment capable <strong>of</strong> accommodating a variety <strong>of</strong>activities.//Outdoor areas shall be enclosed and secured by fences or walls. Design shall be approvedby the Contracting <strong>Office</strong>r. Gates and locking arrangements for the yards shall be provide foregress to comply with NFPA 101.//5.5 UTILITIES5.5.1 WATER DISTRIBUTION SYSTEMDesign and construct system to provide adequate water service for maximum domestic andfire protection requirements.Place isolation valves to provide control over reasonably sized area. In addition, designatevalves in fire hydrant branches and building service lines, near their connection to feedermains.Where reduced pressure backflow preventers are required, provide positive drainage.Connection fees, meter, and system impact fees, as required by the water provider to connectto the existing water distribution system, are the responsibility <strong>of</strong> the Lessor.A. //Domestic Water Pumping SystemIf onsite pumping for domestic water is required, use a three-pump system. Size one pump forapproximately one-third <strong>of</strong> the total water demand. Each <strong>of</strong> the other pumps shall be sized forapproximately two-thirds <strong>of</strong> the total demand. The smaller will operate until water demandexceeds the pump's capacity, at which point it will stop and one <strong>of</strong> the other larger pumps shallstart. When the demand exceeds the capacity <strong>of</strong> this larger pump, the smaller pump willrestart and both pumps will operate together. The other large pump will be a standby andalternate with the first large pump. Provide a pneumatic tank and "NO-FLOW" shut-downcontrols.//5.5.2 WATER SUPPLY FOR FIRE PROTECTIONAssess adequacy <strong>of</strong> the water supply. The Lessor must verify the locations involved as wellas the quality and accuracy <strong>of</strong> the data. Perform water supply flow testing.Fire flows shall be available as required by NFPA 13 for the required occupancy classification.//However, duration for Ambulatory Health Care occupancies shall not be less than 60minutes.// The Lessor shall verify and submit documentation <strong>of</strong> the fire department’s capability<strong>of</strong> handling the manual fire fighting requirements to the Contracting <strong>Office</strong>r prior to occupancyby the Government.//Fire Pumps:Part I: Basic Solicitation Requirements – Page 85 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]When a fire pump is necessary to supplement fire flow and pressure, size it to comply withNFPA 13 //and 14//.5.5.3 //LAWN IRRIGATION SYSTEMProvide an automatic irrigation system to operate between the hours <strong>of</strong> 10:00 pm and6:00 am.Keep the number <strong>of</strong> irrigation system connections to potable system to a minimum. Equipsuch connections with reduced pressure-type backflow preventers. Limit maximum draft fromany connection to 180 gpm [11.4 L/s].//5.5.4 SANITARY SEWERAGE SYSTEMDesign separate underground sanitary sewerage system, including building connections,manholes, clean-outs, cooling tower waste lines, and all appurtenances.Provide an adequate number <strong>of</strong> sanitary connections from each building.Discharge cooling tower drains, overflows, and blow-down piping systems to the sanitarysewerage system. Provide air gaps to prevent cross connections between sewerage andwater systems.To the extent feasible, do not locate sewer pipes and manholes under pavement. Providemanholes at junctions, changes in direction, changes in slope, and changes in invertelevations <strong>of</strong> sewers 8 inch and above. Clean-outs are required for 4 and 6 inch sewers.Spacing between manholes shall be a minimum <strong>of</strong> 300 feet [91.44 m], except 500 foot[152.4 m] spacing is permitted in straight runs <strong>of</strong> long out-fall sewers unless otherwiserequired by local jurisdictional standards.Limit sanitary trunk sewers to not less than 8 inch diameter and sanitary sewer buildingconnections to not less than 4 inch diameter. Establish sanitary sewer slopes to provideminimum velocity <strong>of</strong> 2 ft/s [0.6 mm/s] when pipe is flowing full; maximum slope shall be 9%.Do not connect storm drainage system to sanitary sewerage systems.Connection fees and system impact fees as required by the municipality to connect to theexisting sewerage system are the responsibility <strong>of</strong> the Lessor.// If a lift station and pump are required, locate them outside <strong>of</strong> the building. If required, designsewage pumping system to discharge at maximum sewage flow rate with largest pump notoperating. The sewage pump system shall be designed with redundancy in mind apply N+1 tothe design.Wet well shall be large enough to allow an interval <strong>of</strong> at least 6 minutes between successivestarts <strong>of</strong> same pump motor throughout entire range <strong>of</strong> estimated flow rates. Include high waterlevel alarm system in wet well, and place warning bell in appropriate location.//Part I: Basic Solicitation Requirements – Page 86 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]5.5.5 STORM DRAINAGE SYSTEMDesign separate underground sanitary and storm sewerage systems, including drainage inlets(yard and curb), junction structures, manholes, open drainage channels and basins, dry wells,etc.Design all components <strong>of</strong> storm sewerage system on basis <strong>of</strong> not less than 10-year stormfrequency for one hour.Comply with the requirements <strong>of</strong> <strong>of</strong>f-site receptor <strong>of</strong> storm water. Retention may be required;however; ro<strong>of</strong> storage <strong>of</strong> storm water is not allowed.Limit storm sewers serving drainage inlets to not less than 8 in [200 mm] diameter andbuilding connections to not less than 4 in [100 mm] diameter. Establish storm sewer slopes toprovide minimum velocity <strong>of</strong> 2 ft/s [0.6 mm/s] when pipe is flowing full. Maximum storm sewerdesign velocity shall be in non-erosive range for specified pipe material.Use State or local standard details for manholes, inlets, endwalls, and pipe cradles. Adjustmaster specifications as necessary.Provide an adequate number <strong>of</strong> storm connections from each building.Storm drainage system shall serve all areas under construction or affected by construction.Design storm drainage system and components based on storm frequency from local codesand methodologies. Comply with the requirements <strong>of</strong> <strong>of</strong>f-site receptor <strong>of</strong> storm water.Retention/detention may be required and should be designed on the percolation results statedin the geotechnical report and the design volumes calculated in the Hydrology and Hydraulicsanalysis. Ro<strong>of</strong> storage <strong>of</strong> storm water is not allowed. Do not connect storm drainage systemto sanitary sewerage systems.//Do not drain outside building sub-soil drain tile to an interior sump pump. If a pump isrequired, locate it outside <strong>of</strong> the building.//5.5.6 GAS DISTRIBUTION SYSTEMCoordinate with gas company concerning housing and/or fencing for gas metering andregulating equipment. Provide gas filter upstream <strong>of</strong> meter.5.5.7 ELECTRICAL SERVICEProvide underground secondary-voltage electrical service from the serving electric utility. Allrequirements <strong>of</strong> the electric utility shall be met, including location <strong>of</strong> service source, abovegroundand underground equipment locations, required easements and/or rights-<strong>of</strong>-access,above-ground equipment protection and screening requirements, location <strong>of</strong> required servicedisconnecting means and/or remote operation for service disconnecting means, as required bythe local Authority Having Jurisdiction or utility, meter location and provisions for meterreadingaccess, co-location <strong>of</strong> service conductors in common trench with other utility services,and all other applicable requirements <strong>of</strong> the electric utility.5.5.8 TELECOMMUNICATIONS SERVICESProvide underground telephone service from the serving telephone provider. Sufficientcapacity shall be provided at the Point <strong>of</strong> Presence (POP) for all telephone outlets identified inPart I: Basic Solicitation Requirements – Page 87 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]this <strong>SFO</strong>, plus 50% spare capacity. Comply with all requirements <strong>of</strong> the telephone provider forcable installation, POP space and security requirements, and POP equipment and accessprovisions. All low-voltage underground cabling shall be installed in a partitioned 4 inchconduit with innerduct or approved equivalent and shall not share joint trenches with otherincoming utilities.Provide underground cable television service from the serving provider. Sufficient capacityshall be provided at the Point <strong>of</strong> Presence (POP) for all CATV outlets identified in this <strong>SFO</strong>,plus 50% spare capacity. Comply with all requirements <strong>of</strong> the cable service provider for cableinstallation, POP space and security requirements, and POP equipment and accessprovisions. All CATV underground cabling shall be installed in a 4 inch conduit with innerductor approved equivalent and shall not share joint trenches with other incoming utilities.Provide cable television service, subject to identical requirements as defined for telephoneservice.5.6 EXTERIOR SIGNAGELessor shall develop and provide a complete exterior signage program to includeidentification, directional, informational, and regulatory signage. Signage must comply withlocal municipality’s codes and specifications. Careful consideration <strong>of</strong> the location <strong>of</strong>monument signs shall be taken to avoid sight triangle encroachment.Lessor shall provide ground mounted, //illuminated,// //non-illuminated,// horizontal monumentsign to identify the Outpatient Clinic //main entrance//.Lessor shall provide foundations //andelectrical power// as necessary. Base shall be concrete or masonry and shall be compatiblewith building design and landscaping scheme. Monument sign shall be //5’-0" high x 12’-0"wide// //4’-0" high x 10’-0" wide// //4’-0" high x 8’-0" wide//. VA will furnish message layout,content, and colors for the monument sign. Graphic process shall be routed out copy backedwith white, translucent acrylic.Lessor shall provide //illuminated// //non-illuminated,// wall mounted building identificationsigns <strong>of</strong> dimensional //powder coated// //anodized// aluminum letters and numerals with VAlogo. Letters and numerals shall be minimum //12// //18// //24// //30// //36// inches high. Logoshall be <strong>of</strong> design provided by VA and shall be //27// //42// //56// //70// //84// inches high. Signmessages shall be as follows:Facility Name: [insert name <strong>of</strong> outpatient clinic here]. VA logo shall precede facility name.Address sign shall consist <strong>of</strong> numerals for the building street address.Wall mounted building signs shall be prominently located to be visible from street approach inaccordance with VA-approved building elevations.5.7 FENCINGProvide perimeter fencing or walls and gates. Design fencing with due consideration forcharacter and aesthetics <strong>of</strong> the building design and surrounding properties.Part I: Basic Solicitation Requirements – Page 88 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Fencing shall comply with security requirements in Section 4 <strong>of</strong> this solicitation and VAPhysical Security Design Manual for Life Safety Protected <strong>Facilities</strong>.Part I: Basic Solicitation Requirements – Page 89 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]SECTION 6 BUILDING DESIGN CRITERIA6.1 STRUCTURALStructural design shall comply with the locally adopted codes and VA Seismic DesignRequirements H-18-8 (http://www.cfm.va.gov/TIL/seismic.asp). Structural members shall be<strong>of</strong> concrete, masonry, or steel. Wood may be used as permitted by building and life safetycodes for the Occupancy Group (Business or Ambulatory Care) and size (floor area) andheight <strong>of</strong> structure required by the clinic program.//Where applicable, a licensed structural engineer shall verify the load-bearing capability <strong>of</strong> theexisting structural elements to support the new design loads. Provide evidence <strong>of</strong> compliancewith lateral force requirements with <strong>of</strong>fer as specified in Paragraph 1.7 HOW TO OFFER.////Where alterations are made to the structural elements in existing buildings, these elementsindividually, and the buildings as units, must maintain adequate strength to safely resist bothgravity and lateral loads. Any resulting deficiencies must be reinforced accordingly.//6.1.1 FOUNDATIONSThe building foundation system shall be designed in accordance with the recommendations <strong>of</strong>the geotechnical report.6.1.2 FLOOR LOADSMinimum uniform basic design live loads shall conform to the locally adopted codes and asfollows.In order to provide a flexible design for occupancy changes in the future, generalized live loadcategories should be applied to large areas <strong>of</strong> the floor plate.Where actual occupancy load requirements or concentrated equipment loads exceed theminimum uniform live loads, the areas in question shall be designed to meet the specific loadconditions.6.1.3 ROOF LOADRo<strong>of</strong> live loads shall be based on geographical location and local governing building coderequirements; however, they shall not be less than 20 psf [0.96 kPa].VA may install a ro<strong>of</strong>top mounted satellite system or other ro<strong>of</strong>top antennas for the building.The Lessor shall provide a ro<strong>of</strong> structure, which accommodates VA’s system, and shallcoordinate with VA to provide the required structural mounting devices.6.1.4 LATERAL FORCESVA classifies Outpatient Clinics as "essential" or "critical" facilities. Design structures forlateral forces in accordance with local building code requirements for wind and seismic forcesusing importance factors for essential structures.Part I: Basic Solicitation Requirements – Page 90 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]In addition to local code requirements, all new facilities//, new additions, and existing buildingsrequiring major renovation and/or seismic strengthening// shall be designed in accordancewith VA Seismic Design Requirements H-18-8.6.1.5 SPECIAL INSPECTIONSLessor shall comply with all special inspection requirements <strong>of</strong> the local Authority HavingJurisdiction. Lessor shall obtain services <strong>of</strong> qualified, independent entities to provide specialinspection services during construction. Lessor shall provide copies <strong>of</strong> the inspectors’ reportsto the Contracting <strong>Office</strong>r as evidence <strong>of</strong> compliance with Codes and the requirements <strong>of</strong> thissolicitation.6.1.6 BLAST LOADSDesign structural systems for overpressures and dynamic loadings for threat category asestablished by VA Physical Security Design Manual for Life Safety Protected facility.6.2 ARCHITECTURAL6.2.1 //FOUNDATION DRAINAGESubsoil (foundation) drainage provides a means <strong>of</strong> removing water that may percolate to thefooting level <strong>of</strong> a building foundation system. Reference the geotechnical report for specificpercolation results. Provide a subsoil drainage system in accordance with site Hydrology andHydraulics studies. Subsoil drains shall maintain a pitch as uniform as possible and shalldrain to suitable outfall. No subsoil drainage piping shall traverse a building area to reach anoutfall.//6.2.2 PATIENT ENTRANCESProvide canopies over patient entrances to outpatient clinic. The canopies shall extend 2 feet[0.6 m] beyond the curb lines to protect patients from inclement weather. To reduce the sizeand cost <strong>of</strong> canopies, locate the curb line near the entrance if compatible with other designconsiderations.6.2.3 AMBULANCE ENTRANCESProvide ambulance entrance as indicated on conceptual plan. Ambulance entrances shallinclude provisions for wheelchair and litter access.//Provide a canopy over the loading/unloading zone at ambulance entrance with 13-foot[3.96-meter] vertical clearance from grade to underside <strong>of</strong> canopy. The canopy shall overhangthe rear <strong>of</strong> the parked ambulance 4 feet [1.22 m].////Enclose ambulance entrances where the outside winter design temperature is below 10 ˚F[-12 ˚C], as given in the 99% column <strong>of</strong> Table I, ASHRAE Handbook <strong>of</strong> Fundamentals. Equipthe enclosed entrances with automatic overhead type doors operable from both outside andinside the enclosure.//Part I: Basic Solicitation Requirements – Page 91 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]6.2.4 LOADING DOCKSLoading dock platforms shall be 4 feet [1.22 m] above the driveway. Platforms shall have aminimum depth <strong>of</strong> 8 feet [2.44 m] front to back or between dock lift/leveler and back wall.Provide a canopy over the platform with 14 feet [4.27 m] <strong>of</strong> clearance from grade to theunderside <strong>of</strong> the canopy. Provide a stair or a ramp to the platform.Provide dock levelers where shown on conceptual plans. Dock levelers shall be //manual////hydraulic// with 25,000 pound [11,340 kg] capacity for recessed installation at loading dock.6.2.5 //CANOPIES OR COVERED WALKS////Provide canopies or covered walkways from the outpatient clinic building to locations asshown in the conceptual plans. If canopies or covered walks extend over truck or bus trafficareas, provide 14 feet minimum vertical clearance for vehicular traffic.//6.2.6 ENCLOSURE SYSTEMSBuilding envelope systems shall be designed with consideration for performance under localclimactic conditions, appearance, durability, security, efficiency in construction, andmaintenance and operating costs. Comply with the requirements <strong>of</strong> this <strong>SFO</strong> for SustainableDesign and Energy Efficiency, Paragraph 4.8.Design for heat loss or gain in accordance with energy criteria in this solicitation. Providevapor barriers at appropriate side <strong>of</strong> construction based on local climatic conditions.Fire resistance <strong>of</strong> building envelope systems shall be as required by applicable codes forconstruction type and exposure.A. Exterior WallsMaterials and colors shall be consistent with the overall design concept and structuralrequirements, and provide the level <strong>of</strong> physical security required by this solicitation. Wallsshall be designed to prevent moisture penetration. Detail and construct moisture barriers, wallcavities and weeps, flashings, and other features as necessary to prevent damage to wallcomponents or entry <strong>of</strong> moisture into building. Masonry parapet walls are potential sources <strong>of</strong>water penetration, unequal thermal expansion, additional structural loads, and increasedcosts. Proposed parapet walls must be justified by aesthetic, functional, or economicconsiderations.Structural design <strong>of</strong> walls shall comply with Paragraph 6.1. The weight <strong>of</strong> masonry curtainwalls or veneer shall be supported by the structural frame at each floor.Design walls for sound transmission control from external sources at sites near airports,freeways, //[___]// or heavy city traffic.B. FenestrationLessor shall provide fenestration (windows) consisting <strong>of</strong> fixed windows, or glazed storefrontor curtain wall, including glazed entrance systems, consistent with the overall design concept.Size windows and select glazing and frame materials to meet the overall building envelopeperformance and sustainability requirements <strong>of</strong> this <strong>SFO</strong>.Window sills/stools shall be a minimum <strong>of</strong> 18 inches [457.2 mm] above the finished floor.Part I: Basic Solicitation Requirements – Page 92 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Windows in examination and treatment rooms shall be designed to maintain patient privacy.Use clerestory windows, patterned or obscured glazing, or other methods as appropriate.Windows shall comply with Security requirements in SECTION 4 <strong>of</strong> this solicitation. Providesecurity screens where required by SECTION 4.(1) //Safety GlazingGlaze windows occurring in security exam rooms or security holding room with 7/16" thicklaminated glass. Provide laminated glass for interior panes <strong>of</strong> double-glazed windows in theserooms.//C. Louvers and ScreensProvide louvers in wall openings where required for ventilation. Design louvers andanchorage for wind loads in accordance with building codes. Louvers shall bear AMCAcertified rating seals for air performance and water penetration ratings. Provide bird screenson mechanical ventilation supply and exhaust openings in exterior walls. Provide insectscreens on the inside <strong>of</strong> louvered openings in exterior walls where there are no ductconnections.Comply with security requirements in SECTION 4 <strong>of</strong> this solicitation.D. Exterior DoorsEntrance doors shall be //revolving// //automatic sliding// //swinging// anodized aluminumconstruction with safety glazing and shall comply with energy and sustainability requirements.Swinging exterior doors and frames, except entrance doors, shall be heavy duty, insulated, fullflush, hollow steel construction. Exterior doors shall be weather-stripped, self-closing, andopen outward. Door hardware shall comply with applicable portions <strong>of</strong> SECTION 7 <strong>of</strong> thissolicitation. Provide latch guards and hinges with non-removable pins to deter tampering orunauthorized entry.Doors for vehicular access, including doors to //warehouse,// //engineering shops,// //spacescontaining building service equipment,// //and enclosed ambulance entry// shall be //insulated,industrial grade sectional overhead doors// //overhead coiling doors//. Nominal size <strong>of</strong> thedoor opening shall be //8’-0" wide x 9’-6" high// //[____]//. Doors shall be fully weather-strippedand include an electric operator and manual chain hoist operation. Operator controls shall belocated on the secure (interior) side <strong>of</strong> the opening and shall incorporate a cylinder lock.Provide safeties, including door edge sensors. Overhead door(s) shall not have vision lights.(1) Automatic DoorsDesign automatic doors to operate manually in event <strong>of</strong> power failure. Equip controls withsafety devices for pedestrian protection. Provide door operator controls and equipment thatare easily accessible for maintenance. Design automatic doors to open from both sides.E. Ro<strong>of</strong>sProvide ro<strong>of</strong>ing systems to comply with building codes and fire resistance requirements.Design all ro<strong>of</strong>s with slope to ro<strong>of</strong> drains or gutters. Ro<strong>of</strong>s shall not slope to level valleys, butmay have one-way slopes to gutters at gravel stop edges.Size ro<strong>of</strong> drains and overflow drains, scuppers, or gutters; and leaders or downspouts tocomply with plumbing codes. Locate drains at points <strong>of</strong> maximum deck deflection wherepossible. Coordinate ro<strong>of</strong> drainage with site (storm) drainage. Where ro<strong>of</strong> drain leaders doPart I: Basic Solicitation Requirements – Page 93 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]not connect directly to storm drains, provide scuppers under all sidewalks and flatwork toconvey storm flow to site drainage system.Design ro<strong>of</strong>ing systems (including anchorage <strong>of</strong> ro<strong>of</strong> insulation to decks) for wind forceresistance in accordance with Factory Mutual Global (FM-Global) Criteria:Loss Prevention Data 1-7, "Wind Forces on Buildings and Other Structures"Loss Prevention Data 1-28, "Insulated Steel Deck" Loss Prevention Data Technical Advisory Bulletin 1-29, "Loose-Laid Ballasted Ro<strong>of</strong>Coverings" Loss Prevention Data 1-49, "Perimeter Flashing"Use minimum 8-inch high base flashing at walls and penetrations. Do not use pitch pockets orsimilar penetration seals.VA may require a ro<strong>of</strong>top mounted satellite system or other ro<strong>of</strong> top antennas for the building.The ro<strong>of</strong> shall be maintained in a watertight condition at all such mounting locations. Provideappropriate sized conduit sleeving and weatherpro<strong>of</strong> box at ro<strong>of</strong> end <strong>of</strong> conduit sleeve.Shield ro<strong>of</strong>-mounted equipment from view. Ro<strong>of</strong> structures, such as penthouses andarchitectural screens, shall be compatible in appearance with the material, texture, color, andshape <strong>of</strong> the building.Whenever mechanical equipment requiring periodic maintenance is installed on a ro<strong>of</strong>, provideaccess to ro<strong>of</strong> areas by industrial stair. Provide ro<strong>of</strong> walkways with nonslip surfaces onaccess routes over ro<strong>of</strong>s to mechanical equipment requiring recurrent maintenance. If thestair (or fixed ladder) is exterior to the building, provide means to prohibit unauthorized accessto ro<strong>of</strong>.Design low slope ro<strong>of</strong> systems in accordance with the recommendations <strong>of</strong> the NationalRo<strong>of</strong>ing Contractors Association (NRCA) Ro<strong>of</strong>ing and Waterpro<strong>of</strong>ing Manual and this manual.Acceptable low slope ro<strong>of</strong> systems include but are not limited to the following ro<strong>of</strong>ingmembranes with ro<strong>of</strong> insulation:Bituminous built-up ro<strong>of</strong>ing systemsModified bituminous ro<strong>of</strong>ing systemsSingle-ply sheet ro<strong>of</strong>ing systemsFluid-applied ro<strong>of</strong>ing systemsDesign low-slope ro<strong>of</strong> systems with a positive slope a minimum <strong>of</strong> 1:50 (0.25 inch per foot) upto a maximum <strong>of</strong> 1:12 (1.0 inch per foot) to drains. Use tapered insulation, sloped structuralsystems, or level structural system with sloped fill to achieve the required slope.F. SkylightsWhen provided, skylights shall be self-supporting, aluminum framed style with //translucent,insulated sandwich panels// //fixed glazing//. Lessor shall design, engineer, fabricate, andinstall skylights to meet building code requirements and as follows:Part I: Basic Solicitation Requirements – Page 94 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Design for uniform live load <strong>of</strong> not less than 30 psf [1.44 kPa].Design for a concentrated load <strong>of</strong> not less than 250 lbs [113.4 kg] applied to anyframing member at a location that will produce the most severe stress or deflection.A one-third increase in the allowable stress for wind is acceptable where permitted bycode but not in combination with any reduction applied to combined loads.Assume that compression flanges <strong>of</strong> flexural members receive effective lateral bracingonly from anchors to the building structure and horizontal glazing bars or interior trimin contact on at least 50% <strong>of</strong> the member’s total length.Provide for expansion and contraction <strong>of</strong> metal skylight components resulting from an ambienttemperature differential <strong>of</strong> not less than 120 ˚F [49 ˚C].//6.3 EQUIPMENT6.3.1 GENERALPART III <strong>of</strong> this Solicitation (Schedule B) lists special equipment items to be furnished byeither the Lessor or VA for installation in the Outpatient Clinic. As part <strong>of</strong> the rentalconsideration, the Offeror must include supporting construction, HVAC systems, utilities, andelectrical distribution systems for both Offeror-furnished equipment and VA-furnishedequipment to be installed in the Outpatient Clinic.Offeror shall include provisions for necessary support and attachment <strong>of</strong> equipment itemsincluding, but not limited to, structural reinforcement <strong>of</strong> wall, floor or ro<strong>of</strong> construction, andblocking or backing in walls and ceilings.Offeror shall provide HVAC systems necessary to supply and exhaust the clinical spaces,laboratories, and other areas that contain special equipment, including provisions for supply orexhaust connections directly to special equipment items when required for installation and/oroperation <strong>of</strong> the equipment, as part <strong>of</strong> the rental consideration.Offeror shall provide building equipment and utility systems including but not limited to piping,water treatment equipment, sanitary or laboratory waste systems, medical or laboratory gas,compressed air, and vacuum systems as required for the installation and operation <strong>of</strong> thespecial equipment items as part <strong>of</strong> the rental consideration.Offeror shall provide electrical service necessary for special equipment items, includingservice from emergency source for designated items or locations, as part <strong>of</strong> the rentalconsideration.The prices and costs relating to Schedule B Special Requirement items shall include only thedirect installation <strong>of</strong> equipment to support and distribution systems already included in thebasic rent. Therefore, no additional costs relating to the distribution <strong>of</strong> utilities or supportingconstruction may be ascribed to the special equipment costs in Schedule B.Items not listed in Schedule B are to be provided by the Lessor as part <strong>of</strong> the rentalconsideration.Part I: Basic Solicitation Requirements – Page 95 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]6.3.2 LESSOR FURNISHED SPECIAL EQUIPMENTThe Offeror shall submit lump-sum pricing for the purchase and installation <strong>of</strong> specialequipment items specified in Schedule B for laboratory and clinic areas. The price for eachitem in Schedule B shall include only the direct costs <strong>of</strong> obtaining and installing the item.Special equipment items are listed by room type for each functional area within the OutpatientClinic.Special systems and equipment (including special electronic safety and security systems)applicable to the entire clinic are listed separately in Schedule B.All property placed in, upon, or attached to the premises to be leased, and for which theGovernment pays by means <strong>of</strong> lump-sum, shall be and remain the property <strong>of</strong> theGovernment, and may be removed or otherwise disposed <strong>of</strong> by the Government.6.3.3 //PROVISIONS FOR VA-FURNISHED/VA-INSTALLED EQUIPMENT////As part <strong>of</strong> the rental consideration, the Offeror shall include supporting construction, HVACsystems, utilities, and electrical distribution as required for VA-furnished and VA-installedequipment to be installed in the Outpatient Clinic.//A. //VA-Furnished/Lessor Installed Equipment////Equipment may include items that are furnished by VA but installed by the Lessor. As part <strong>of</strong>the rental consideration, the Offeror shall include supporting construction, HVAC systems,utilities, and electrical distribution as required for VA-furnished equipment to be installed by theLessor.For equipment designated as installed by the Lessor, the Offeror shall also include installationas part <strong>of</strong> the rental consideration. Installation shall be defined to include all labor, tools,equipment, and incidental parts (including, but not limited to, screws or bolts for anchoringequipment to substrates, pipe fittings or unions, solder, Teflon tape, pipe joint compound, wirenuts or electrical connectors, electrical wire, etc.) necessary for the equipment to be placed inits final location and to be completely functional.Include activities (nodes) in the network analysis schedule for installation by Lessor <strong>of</strong>VA-furnished equipment.Advise Contracting <strong>Office</strong>r <strong>of</strong> date(s) work will be ready for installation <strong>of</strong> equipment.Accept delivery <strong>of</strong> VA-furnished equipment on established dates.Jointly with Contracting <strong>Office</strong>r, inspect the equipment upon delivery to check fordamage and confirm quantities.Once VA-furnished equipment is accepted by Lessor, the Lessor shall be responsiblefor protecting and storing the equipment.Provide any additional transportation to move equipment to final location.Uncrate, assemble, and install equipment.Demonstrate proper operation <strong>of</strong> equipment to the Contracting <strong>Office</strong>r.//Part I: Basic Solicitation Requirements – Page 96 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]6.4 MECHANICAL6.4.1 INTRODUCTIONA. GeneralThe Offeror and the Project Design Engineer (henceforth known as the Engineer) shall use thecontents <strong>of</strong> this document to design, install, test, adjust, balance, and commission the HVACsystems in a trouble-free working manner to provide comfort and safety to the veterans, staff,and visitors. The systems shall operate within the specified parameters.B. Equipment LocationEquipment (examples: Air-Handling Units, Cooling Towers, Chillers, DX Condensing Units,and Fans) can be located on the ro<strong>of</strong> if permitted by the local authorities. Provide supports,bracings, and other mounting devices to withstand wind forces as required by the localauthorities. If there are no local codes, use wind forces indicated in American Society <strong>of</strong> CivilEngineers (ASCE) 7-98 or later version if available. For the seismic zones, the design <strong>of</strong> thebracing and supports shall be certified by a registered pr<strong>of</strong>essional structural engineer. SeeParagraph 6.2.6E for additional safety and access requirements.6.4.2 MANDATORY PROVISIONSSee Paragraph 4.1 CODES and 4.2.1 VA ADOPTED CODES, STANDARDS, ANDEXECUTIVE ORDERS.6.4.3 APPLICABLE CODES AND CRITERIASee Paragraph 4.1 CODES.6.4.4 HVAC DESIGN CALCULATIONSThe HVAC design calculations shall be based on the following parameters:A. Outdoor Design ConditionsReference: Latest Edition <strong>of</strong> ASHRAE Handbook <strong>of</strong> Fundamentals.(1) Cooling Mode – Air Handling Unit (Minimum Outdoor Air)1%, Monthly Design Dry bulb and Mean Coincident Wet bulb Temperatures.(2) Cooling Mode – Air Handling Unit (100% Outdoor Air):1%, Monthly Design Wet bulb and Mean Coincident Dry bulb Temperatures.(3) Heating Mode99%, Annual Design Dry bulb Temperature.(4) Cooling Tower Selection1%, Monthly Design Wet bulb Temperature.B. Indoor Design Conditions(1) Health Care Functions Surgery and Post Anesthesia Recovery Areas Radiology Diagnostic and Treatment SterilizingPart I: Basic Solicitation Requirements – Page 97 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Central Medical and Surgical SupplyReference: Latest Edition <strong>of</strong> ASHRAE Standard 170 (Ventilation <strong>of</strong> Health Care <strong>Facilities</strong>)Base the design on the following parameters listed for each unique specialty function:Inside Design Temperature (Dry bulb)Inside Design Humidity (Percentage Relative Humidity)Pressure Relationship to Adjacent Areas (Measured as Volumetric Air Difference)Minimum Total and Outdoor Air Changes per HourReturn Air or Exhaust to Outdoors(2) Support Functions <strong>Office</strong>s Classrooms Conference Rooms Entrance Lobby Waiting Area Lounge Circulation Spaces70 ˚F @ 30% Relative Humidity (Heating Mode)75 ˚F @ 50% Relative Humidity (Cooling Mode)(RH in cooling mode is uncontrolled)(3) Food Service Kitchen 70 ˚F to 74 ˚F (Heating Mode) 82 ˚F to 84 ˚F (Cooling Mode)Dining Areas70 ˚F @ 30% Relative Humidity (Heating Mode)75 ˚F @ 50% Relative Humidity (Cooling Mode)(RH in cooling mode is uncontrolled)(4) Miscellaneous SpacesSee Paragraph 6.5 for specific applications.(5) Unoccupied ModeNon-sensitive areas shall be provided with a night setback, 55 to 88 F.C. Heating and Cooling Capacities(1) GeneralUsing the methodology given in the latest edition <strong>of</strong> ASHRAE Handbook <strong>of</strong> Fundamentals, theEngineer shall provide computerized calculations showing computation <strong>of</strong> the cooling andheating capacities <strong>of</strong> the occupied spaces. The Engineer shall coordinate with the projectspecificancillaries – Latest Edition <strong>of</strong> ASHRAE Handbook <strong>of</strong> Applications (Health Care<strong>Facilities</strong>) and obtain such data as equipment load, exhaust air volume, pressurizationrequirements, and the required hours <strong>of</strong> the system operation per day to establish the coolingand heating capacities and system zoning.Part I: Basic Solicitation Requirements – Page 98 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY](2) Calculation DetailsThe computerized calculations shall show such entities as:Room-By-Room Peak Cooling and Heating LoadsRoom-By-Room Air Balance Sheets, showing supply, return, exhaust, make-up, andrelief air volumesZone cooling and heating loads (a zone is defined as a central cooling and heatingapparatus serving a group <strong>of</strong> rooms)Psychometric Analysis(3) System LossesThe calculations shall include minimum 12% to the calculated load to account for:Fan Motor HeatDuct Heat Pick-UpDuct LeakageAssumed Safety FactorReference: ASHRAE Handbook <strong>of</strong> Applications6.4.5 HVAC SYSTEM SELECTION CRITERIA – AIR SIDEA. GeneralSelection <strong>of</strong> the airside <strong>of</strong> the HVAC systems shall be based on the following:All-Air SystemsFan Coil UnitsClosed-Loop, Ground Source Heat PumpsUse <strong>of</strong> PTAC (Packaged Terminal Air Conditioners) and Terminal Heat Pumps is NOTpermitted6.4.6 ALL-AIR SYSTEMSA. GeneralProvide all-air system, where the space criteria require:Minimum Fixed Air Changes per Hour100% Exhaust to OutdoorsPositive (+) or Negative (-) Pressure Relationship with Adjoining SpacesThe AHU shall be:ARI CertifiedFactory-Fabricated and TestedModular Design with Solid Double-Wall <strong>Construction</strong>Provide IAQ (Indoor Air Quality), double-slopping drain pan to ensure immediate removal <strong>of</strong>condensate. Provide a variable air volume system (VAV), where variation in air volume ispermitted.Part I: Basic Solicitation Requirements – Page 99 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]B. ZoningProvide multiple air-handling units to ensure flexibility and energy efficiency. Capacity <strong>of</strong> asingle air-handling unit shall not exceed 50,000 CFM. Provide dedicated air-handling units forspaces, such as: Emergency Care Unit Surgery and Post Anesthesia Recovery Areas Supply Process and Distribution (SPD) also referred to as Central Medical andSurgical Supply Cafeteria and Kitchen Entrance Lobby, Admission, and Waiting Ancillaries (as defined in ASHRAE Application Handbook – Health Care <strong>Facilities</strong>)The above functions and activities shall vary with the size and space program <strong>of</strong> the OPC(Outpatient Clinic).C. AHU Components and Specifications(1) GeneralAll components may not be required at each location and for each application.(2) FiltrationThe following filtration requirements shall apply: Pre-filters = 2-inch thick disposable (MERV 8) After-Filters = 12-inch thick disposable (MERV 14) Locate pre and after filters back-to-back, on the upstream side <strong>of</strong> the supply air fan. Provide HEPA filters (MERV 17) as the terminal final filters for Operating Rooms, andBMT (Bone Marrow Transplant).Contaminated exhaust <strong>of</strong> the special systems serving hoods or biological safety cabinets orprotective environment rooms (e.g., TB Isolation Rooms) shall pass through the HEPA filters(MERV 17) equipped with pre-filters (MERV 8).(3) HumidificationHumidification shall be provided to ensure a minimum <strong>of</strong> 30% RH. Where the campus steamis available, use an unfired steam-to-steam generator to produce low-pressure clean steam forserving the unit-mounted or main supply air duct-mounted steam humidifiers. Use RO(Reverse Osmosis) water to produce clean steam. Provide a gas-fired, stand-alone steamgenerator for the steam humidifier in the absence <strong>of</strong> the campus steam. Use <strong>of</strong> the electric,stand-alone steam generator should be considered as a last option.(4) BlendersInclude blenders where blending <strong>of</strong> cold air and return would be helpful in preventing nuisancetripping activated by the Freeze stat.D. Air Terminal UnitsProvide pressure-independent, DDC-controlled, variable air volume (VAV) and constantvolume (CV) terminal units. Provide integral reheat coils for the terminal units servingperimeter and ro<strong>of</strong>-exposed spaces. Full shutdown <strong>of</strong> the interior spaces is permittedprovided provision is made in the design sequence to prevent overcooling. Providemodulating control with hot water as the heating medium. Provide SCR control where electricPart I: Basic Solicitation Requirements – Page 100 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]coils are used for reheat. Provide capability to adjust the air volume between the high and lowlimits either locally or by the DDC controls. Provide acoustic internal lining for the terminalunits.Exception: Terminal units serving Surgery shall be constructed from stainless steel and shallbe fabricated without acoustic lining.Capacity <strong>of</strong> a single terminal unit shall not exceed 1,500 CFM [708 L/s].Exception: Terminal unit serving the Operating Room can be larger than 1,500 CFM[708 L/s], as required to meet the air changes and cooling load requirements.E. Room Temperature Control(1) GeneralA space is defined as individually-controlled when it is equipped with a dedicated air terminalunit controlled by a dedicated room temperature sensor. The temperature sensor shall bewall-mounted with adjustable setpoint.(2) Individual Room Temperature ControlProvide individual room temperature control for the following spaces:Occupied Corner Spaces with two or more exposed perimeter wallsSpaces listed below (Interior or Perimeter)o Conference Roomo Laboratoryo Operating Roomo Special Procedure Roomo Minor Operating Roomo Trauma Roomo Diagnostic and Treatment Roomo Classroomo Entrance Lobbyo Loungeo Dining Roomo Kitcheno Sterilizer Equipment Roomo Clean Preparation and Storage Roomo Soiled or Decontamination Room(3) Zone Temperature Control – Perimeter SpacesA single terminal box can serve as many as three perimeter spaces if these spaces arelocated on the same exposure and have identical load characteristics, such as <strong>of</strong>fices orexamination rooms.(4) Zone Temperature Control – Interior SpacesA single terminal box can serve as many as four interior spaces if these spaces have identicalload characteristics, such as <strong>of</strong>fices or examination rooms.(5) Temperature Control – Interior and Perimeter SpacesA single terminal unit cannot serve perimeter and interior spaces, including circulation spaces.Part I: Basic Solicitation Requirements – Page 101 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY](6) Temperature Control – Open SpacesOpen spaces with exposed perimeter and interior spaces shall be divided into two sub-zones,perimeter and interior. Each sub-zone shall be served by a dedicated air terminal unit. Openspaces are defined as the spaces without floor to ceiling partitions.F. Air Distribution ArrangementProvide fully ducted supply, return, and exhaust air systems between the fans andinlets/outlets. Use <strong>of</strong> partial or common ducted return air arrangement is not acceptable. Toavoid contamination and other shortcomings cited below, do not use ceiling space betweenthe structural ceiling and suspended ceiling space as the supply or return air plenum.In the ASHRAE Application Handbook (2007 Edition), drawbacks <strong>of</strong> plenum return system arecited as reproduced below:"Suspended ceiling return air plenums eliminate sheet metal return air ductwork to reducefloor-to-floor height requirements. However, suspended ceiling plenums may increase thedifficulty <strong>of</strong> proper air balancing throughout the building. Problems <strong>of</strong>ten connected withsuspended ceiling return plenums are as follows:Air leakage throughout cracks, with resulting smudges.Tendency <strong>of</strong> return air openings nearest to a shaft opening or collector duct to pulltoo much air, thus creating uneven air motion and possible noise.Noise transmission between <strong>of</strong>fice spaces."G. AHU Controls(1) GeneralProvide a fully functional automatic control system to ensure comfort and energy efficiencyfrom full load to part load conditions, with integral safety features to protect the occupants andequipment.(2) System Components and Minimum SequencesProvide motorized control valves, automatic dampers, airflow measuring devices, a staticpressure sensor, chilled-water flow meters, temperature, pressure, and humidity sensors,humidifiers, smoke detectors and smoke dampers, as required, to address such sequencesas: Supply Air Temperature Control Fan Speed Control Provision <strong>of</strong> Minimum Outside Air from Full Load to Part Load System Start-Up Morning Warm-Up and Night Setback Cycles Smoke Detection Alarms6.4.7 FAN COIL UNITSA. GeneralProvide a 4-pipe fan coil unit system for spaces not required to be in compliance with thecriteria cited in Paragraph 6.4.6A above. Cooling only fan coil units are permitted, where yearroundcooling is required for applications, such as elevator machine room, telephone room,and computer room. Provide at least one fan coil unit for each room. A single fan coil unitcannot serve two or more rooms by ducted supply air take<strong>of</strong>fs. Use <strong>of</strong> a 2-pipe fan coil unitsystem, with seasonal changeover, is not permitted.Part I: Basic Solicitation Requirements – Page 102 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]B. Minimum OA – VentilationDo not admit raw minimum outside air (for ventilation) from the exterior wall vents. Provide adedicated, central air-handling unit, complete with air distribution ductwork and outlets, toadmit conditioned and filtered ventilation air directly in the occupied spaces and NOT viamixing boxes. Components <strong>of</strong> the central ventilation units shall be similar to the all-air system.C. Fan Coil Units – TypeFan coil units shall be one <strong>of</strong> the following types:Vertical Floor MountedHorizontal RecessedHorizontal ConcealedD. Fan Coil Units ControlsProvide modulating controls for the cooling and heating coils. Provide a dead-band betweenthe cooling and heating modes to avoid simultaneous activation <strong>of</strong> cooling and heatingsystems.6.4.8 CLOSED-LOOP – GROUND SOURCE HEAT PUMPS (GSHP)A. GeneralEvaluate and include the closed-loop heat pump system in the design where land area isavailable to install the outside underground loop. Heat pumps can be used where an all-airsystem is not feasible.B. Closed-Loop System Selection(1) GSHP TypeThe ground source heat exchangers are installed in horizontal or vertical configuration.The vertical heat exchanger is commonly used, as it has lesser land requirement compared tothe horizontal type.(2) Test BoreSample boring or test bore is highly recommended to estimate approximate depth <strong>of</strong> the boreand soil condition, i.e., thermal properties. Test bore data shall enable the designer tooptimize the loop design and eliminate assumptions from the design process.The test bore can be used as a permanent ground heat exchanger.(3) Commonly Used Design ParametersThe commonly used parameters are: Bore Diameter = 4 to 6 inches [101 to 152 mm] Bore Placing = 20 to 30 feet [6 to 9 m] Pipe Diameter = 1 inch up to approximately 300 feet [91 m] 1-1/4 inch up to approximately 500 feet [152 m] 1-1/2 inch for depths greater than 500 feet [152 m] Piping Material: HDPE (High-Density Propylene) – thermally fused(4) Loop TypesSelect the loop design and configuration based on the type <strong>of</strong> buildings. Evaluate and includeany one <strong>of</strong> the following three loops:Part I: Basic Solicitation Requirements – Page 103 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Simple unitary loopSub-centralCentralThe designer may select any one or combination <strong>of</strong> the above loops.C. Heat PumpsUse water-to-air heat pumps with differing configurations to match the applications.Examples:Vertical (up-flow or down-flow)HorizontalClassroomConsoleD. Minimum Outdoor Air – VentilationProvide a dedicated, central air-handling unit with a heat recovery system for colder climatewhere outdoor design temperature at 99% is 41°F [5°C] or lower.6.4.9 REFRIGERATION SYSTEMS – CHILLED WATER AND DIRECT-EXPANSION (DX)SYSTEMSProvide ARI certified, air-cooled or water-cooled refrigeration units.Use EPA approved refrigerants (HFC-134a, HFC-410a, or HCFC-123).Use <strong>of</strong> HCFC-22 refrigerant is not permitted.Provide multiple units (minimum two) to ensure flexibility and efficient part load operation. Use<strong>of</strong> reciprocating compressors is NOT permitted. Equipment efficiencies shall be in compliancewith the DOE, FEMP program.6.4.10 CHILLED WATER SYSTEMSA. GeneralCapacity <strong>of</strong> a single air-cooled chiller shall not exceed 200 tons. Capacity <strong>of</strong> a single watercooledchiller (Centrifugal or Rotary Screw) shall not exceed 1,250 tons. Provide multiplechillers (at least two) to ensure reliability and efficient part load operation. A chilled watersystem shall be provided for all 100% OSA units.B. Chiller ControlsEach chiller shall be equipped with a factory-installed and tested microprocessor for the safetyand operating controls. The microprocessor shall be able to interface with the building DDC(Direct Digital Controls) controls with a BACNET open protocol arrangement.C. Chilled Water Piping/Pumping SystemProvide a fully functional chilled-water piping and pumping system complete with accessoriesand devices, such as variable-speed drives, flowmeter, and temperature and pressuresensors. Selection <strong>of</strong> the piping and pumping arrangement shall be project-specific. Providevariable flow chilled-water pumping (variable primary or primary-secondary) system to ensureenergy efficient operation from full load to part load conditions.Part I: Basic Solicitation Requirements – Page 104 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]D. Cooling Tower(1) GeneralProvide CTI-certified, corrosion-resistant, gravity-flow cooling tower in induced-draftconfiguration to cool the condenser water. The tower shall be in compliance with OSHA safetyrequirements and Physical Security provisions.(2) Cooling Tower LocationLocate cooling tower to ensure that:Tower installation and noise is not objectionable and in compliance with the localordinance. Provide low noise level fans and attenuators as required to meet the noiselevels.Discharge from the cooling tower does not find its way into outside air intakes andopen windows <strong>of</strong> the adjoining spaces to create a potential for the Legionellosisdisease.(3) Tower Accessories and ControlsThe cooling tower installation shall be accessible and complete with a walking platform and aladder safety cage.(4) Water TreatmentProvide a complete and fully functional water treatment system using non-toxic chemicalsapproved by EPA and local authorities.6.4.11 DIRECT-EXPANSION (DX) SYSTEMSUse <strong>of</strong> DX systems, packaged or split-system, is permitted, provided the occupants comfort isnot compromised due to lack dehumidification at part load conditions. The minimum size unitis 20 tons. The Engineer shall address this issue by including the required control strategyand system configuration, such as:Multiple Compressors (single compressor units are NOT acceptable)Low-Ambient OperationHot Gas BypassCustomized Refrigerant Piping Design (if required to avoid stratification)6.4.12 HEATING SYSTEMSA. GeneralProvide heating hot water or steam boilers to meet the space heating and domestic hot waterheating demand. Provide at least two boilers each <strong>of</strong> 50% capacity to ensure flexibility.Provide 100% back-up for the circulating pumps.B. Selection CriteriaSelection <strong>of</strong> steam and/or hot water boilers shall be based on the following:Total heating loadTotal steam demand for winter humidification, sterilizers, kitchen equipmentDomestic hot water loadLocation <strong>of</strong> heating equipment according to the OPCPart I: Basic Solicitation Requirements – Page 105 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]C. Boiler Fuel Selection and Choice Use natural gas where uninterrupted supply is available. Use No. 2 oil where natural gas is not available. Use natural gas and No. 2 oil where supply <strong>of</strong> natural gas is interruptible. Provide complete fuel oil and/or gas piping with a gas meter.D. Hot Water Heating Piping/Pumping System Provide a fully functional heating system complete with circulating pumps andinsulated piping.Provide two-way modulating control valves to vary flow at part-load conditions.Provide variable speed drives for the hot water circulating pumps for sizes larger than5.0 HP.E. Steam Heating SystemThe steam system shall generate heating hot water by using a steam-to-hot water heatexchanger and steam accessories, such as condensate return system comprising <strong>of</strong>condensate return pump and flash tank, where required. Provide boiler water treatment andsteam flow meter, interfacing with the central metering system.F. Miscellaneous Terminal Heating DevicesProvide thermostatically-controlled terminal heating devices, such as unit heaters, cabinetheaters, convectors, and finned tube radiation to heat the miscellaneous spaces, such as:AtticVestibulesCrawl spaceExterior stairsExit doors leading to outdoorsMechanical Equipment Rooms (MERs)Toilets with exposed perimeter6.4.13 PIPING SYSTEMS – BASIC REQUIREMENTSA. Pipe MaterialSteel, ASTM A53, Grade B, seamless or ERW, schedule 40 for condenser water, chilledwater,hot water, and vent pipes.Copper Water Tube (Option): ASTM B88, Type K or L, hard drawn. S<strong>of</strong>t drawn tubing,¾-inch and larger may be used for run outs to for fan coil units.Use pre-fabricated, insulated, chilled water piping for the underground applications or in thetunnels, or pipe basements or tunnels.Steam Piping: Piping for condenser water, chilled-water, hot water, and vent pipes shall besteel, ASTM A53, Grade B, seamless or ERW, Schedule 40.Steam Condensate Piping: (a) Concealed above ceiling, in wall, or chase: Copper WaterTube ASTM B88, Type K, hard drawn (b) All Other Locations: Copper Water Tube ASTM B88,Type K, hard drawn or steel, ASTM A53, Grade B, Seamless or ERW, or A106 Grade BSeamless, Schedule 80.Part I: Basic Solicitation Requirements – Page 106 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Chemical Feed Water for Condenser Water Treatment: Chlorinated polyvinyl chloride(CPVC), Schedule 80.B. Minimum Pipe SizeMinimum pipe size shall not be less than ¾-inch [19 mm].C. Minimum Water FlowMinimum water flow shall not be less than 0.5 GPM [1.89 L/m].D. Pipe SizingSelect pipe sizes based on the ASHRAE recommendations and the need to provide anenergy-efficient design.E. Piping Connections(1) Shut<strong>of</strong>f ValvesProvide shut<strong>of</strong>f valves to isolate each piece <strong>of</strong> equipment, such as chillers, boilers, coolingtower, pumps, coils, air terminal units, and terminal heating units requiring isolation, service,and/or replacement.Provide drain lines at low points and air vents at high points.(2) StrainersProvide in-line strainers to protect equipment, such as cooling and heating coils and controlvalves.(3) Check ValvesProvide check valves on the pump discharge side with two pumps operating in parallel.(4) Flexible ConnectorsProvide flexible connectors at the pump inlet and outlet connections.(5) FiltersProvide cartridge-type <strong>of</strong> filters for the closed-loop chilled water and hot water systems.Provide solid separators for cleaning condenser water.(6) Water Treatment – Closed-Loop SystemsProvide chemical shot feeder for the closed-loop chilled water and hot water systems.(7) Piping SpecialtiesProvide expansion tanks and air separators for the chilled water and hot water closed-loopsystems.(8) Make-Up Water ConnectionsProvide make-up water connections with reduced pressure backflow preventer for theexpansion tanks.(9) Steam TrapProvide float and thermostatic trap assembly for the equipment served by a modulating controlvalve. Provide at least 12-inch static head to facilitate condensate flow by gravity.Part I: Basic Solicitation Requirements – Page 107 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY](10) Vent LinesProvide vent lines for the steam condensate return pump and pressure-reducing valve stationto discharge outdoors.(11) InstrumentsProvide pressure gauges and thermometers at the pumps and coils and at the equipmentrequiring measurements <strong>of</strong> the pressures and temperatures.(12) Steam GunProvide a steam gun set comprising <strong>of</strong> steam, water, and detergent for cleaning <strong>of</strong> carts in thetrash rooms, kitchen, and sterilizer room.6.4.14 AIR DISTRIBUTION SYSTEMA. ComplianceAll air distribution systems (supply, return, exhaust, relief, and outdoor air) shall be fabricatedin accordance with SMACNA Standards.B. Duct MaterialDuctwork, casings, and accessories (e.g., volume dampers, turning vanes, elbows) shall befabricated from galvanized sheet steel, ASTM A527, coating G90. As an optional material,aluminum sheets complying with ASTM B209, alloy 1100, 3003, 5052 can be used.Use 18-gauge welded stainless steel ducts with liquid-tight continuous welds for all seams andjoints for the "wet exhaust" systems. Wet exhaust systems are meant for dishwashers, cagewashers, cart washers, scullery hoods, steam sterilizers, and ethylene oxide sterilizers.For special exhaust systems serving fume hoods and biological safety cabinets, use weldedstainless steel (ASTM A167, Class 302 or 304).Use duct material in compliance with NFPA 96 and UL labeled for grease exhaust.Use <strong>of</strong> fiberglass ducts, concrete ducts, and underground ducts is not permitted.C. Design Parameters(1) Minimum Duct Sizes 8 inches x 6 inches for rectangular ducts 6 inches for round ducts(2) Recommended Duct VelocitiesSelect the duct velocities and limiting static pressure drops in accordance with ASHRAE andSMACNA requirements. The selection shall address such issues as the noise levels, energyconservation, and the prescribed limits on the total fan static pressure as specified in ASHRAE90.1.D. Ductwork AccessoriesProvide a manual volume damper at each low-pressure branch duct take<strong>of</strong>f. Show all fire andsmoke dampers and smoke detectors on the floor plans.Part I: Basic Solicitation Requirements – Page 108 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]E. Air OutletsProvide supply, return, and exhaust air outlets and inlets to ensure uniform distribution <strong>of</strong> airand avoid spot cooling and dead-end spaces without circulation. The air outlets shall notresult in a drafty and noisy environment. Capacity <strong>of</strong> a single air outlet shall be based on andlimited to meet the noise levels and uniform air distribution.6.4.15 INSULATIONProvide duct and piping insulation in accordance with the ASHRAE Standard 90.1. Externaland internal insulation for the equipment shall be in compliance with the manufacturer'sstandard practice.6.4.16 APPLICATIONSA. Isolation Exam Room RequirementsProvide at least two (2) treatment rooms to isolate potential TB patients until they arediagnosed and moved to an appropriate treatment facility. Each treatment room shall bedesigned to meet the following HVAC requirements:Constant Volume Supply and Exhaust AirIndividual Room Temperature ControlMinimum 12 Air Changes per HourNegative Air Balance (Exhaust Air = 120% <strong>of</strong> Supply Air)Dedicated Exhaust Fan (a common fan can be sued to serve two rooms)Comply with Centers for Disease Control (CDC) requirements for TuberculosisMaintain entire exhaust duct under negative air balance and allow the air to pass through theHEPA filters (MERV 17) and pre-filters (MERV 8). Discharge air from the ro<strong>of</strong> level from a 10-foot [3-meter] high stack at the discharge velocity <strong>of</strong> 3,500 FPM [17.8 m/s] discharge velocity.Care shall be taken to ensure that the exhaust air does not find its way into any outside airintakes and open windows. The minimum recommended distance between the air inlet andexhaust is 25 feet [7.62 m]. Increase this distance as required based on the outcome <strong>of</strong> thedispersion analysis to be performed by the Engineer.The Engineer shall provide a certificate showing compliance with the negative air balance ornegative air pressure by installing required controls and instruments.B. Air-Conditioning Systems – Miscellaneous AreasProvide dedicated and thermostatically-controlled air-conditioning systems for the criticalspaces identified below:Elevator Machine Room: inside design temperature and the range shall be based onthe manufacturer's recommendationsTelephone Equipment Room: refer to 6.8.2.J, Telephone Equipment RoomMain Computer Room: refer to 6.8.2.K, Main Computer Room(1) GeneralObtain project-specific scope <strong>of</strong> work and provide a HVAC system to serve the MRI Suite.Coordination with the MRI vendor is critical, as the mechanical system requirements shalldepend upon the actual make and model number. HVAC system shall be dedicated unless itcan be connected to any other system without compromising the design parameters.Part I: Basic Solicitation Requirements – Page 109 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY](2) Cryogen ExhaustRemoval <strong>of</strong> cryogen during an accidental spill is a critical safety requirement. Coordinate theexhaust needs with a specific make and model number <strong>of</strong> the MRI Unit. Provide multiplelevels <strong>of</strong> safety, such as exhaust, vent, and overpressure relief.(3) Dedicated AC SystemsClosed-loop chilled water unit may be required for the process cooling. Refer also to 6.8.2.J,Telephone Equipment Room and 6.8.2.K, Main Computer Room.C. Storage Rooms and Flammable and Combustible Storage RoomProvide dedicated exhaust ventilation system to maintain the space under negative airbalance. Select fan, motor, and ductwork to handle the stored chemicals. Ensure compliancewith NFPA 30. Exhaust fan shall run continuously and shall be served from the emergencypower circuit.D. LaboratoriesDesign HVAC systems to comply with NFPA 45 with 100% exhaust and negative air balance.Provide dedicated exhaust systems for the fume hoods and Biological Safety Cabinets (BSC).Ductwork, fans, and motors shall be suitable to handle the chemicals. Exhaust from the hoodsand BSC shall be discharged from the ro<strong>of</strong> at appropriate velocity to ensure that contaminatedair does not enter into outside air intakes and open windows.E. Smoking SheltersProvide a dedicated HVAC unit to serve the smoking facility. Safety <strong>of</strong> the non-smokersshould not be jeopardized by indoor smoking. Provide outside air in accordance withASHRAE Standard 62.1-2007. The installation shall be in compliance with Joint Commissionon Accreditation <strong>of</strong> Healthcare Organizations (JCAHO). The system shall be sized to operatefrom the design outside air to re-circulatory mode when not occupied.Design the system to maintain comfort conditions (80 °F [27 ˚C] at 55% Relative Humidity incooling mode and 65 °F [18 ˚C] in heating mode). Ensure that the room exhaust does not findits way into the outside air intakes and open windows.F. Pump RoomsProvide heating and ventilation as required to be in compliance with NFPA 20. Providededicated and controlled equipment.G. Enclosed EntrancesRefer to Paragraph 6.2.3 for the enclosed entrances. Provide independent heating device toactivate and maintain 60 °F [16 ˚C] when the entrance doors are closed in heating season.Use devices such as overhead heating lamps.H. Atrium Smoke ControlA Registered Fire Protection Engineer shall review and approve the engineering calculations<strong>of</strong> the smoke evacuation system.I. Radiology(1) GeneralPenetration <strong>of</strong> lead lining by the HVAC ducts shall be coordinated with the equipmentmanufacturers.Part I: Basic Solicitation Requirements – Page 110 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY](2) Inside Design ConditionsUse ASHRAE Standard 170.(3) Dedicated AC UnitEvaluate the need for a dedicated AC unit to meet the cooling demand <strong>of</strong> the equipment loaddue to computers and other equipment. Coordinate the heat dissipation with the equipmentmanufacturer.(4) Air DistributionCoordinate air distribution with the raised floor where installed in specific rooms. Ensuresupply <strong>of</strong> minimum ventilation room for the spaces cooled by 100% re-circulating AC unit.Maintain room air balance as recommended by ASHRAE Handbook and/or Standard 170.J. General Exhaust SystemsVentilate spaces, such as toilets, janitor's closet, soiled utility rooms, and bathrooms, at therate specified in ASHRAE Standard 62.1. Maintain negative air balance in the spaces.K. Wet Exhaust SystemProvide dedicated wet exhaust system for washers in the kitchen and SPD (SupplyProcessing and Distribution) areas. Provide welded stainless steel ductwork. Coordinateexhaust air volume with the equipment data. Maintain negative air balance in the spaces.L. VestibulesProvide a dedicated terminal heating unit to heat the vestibule. Ventilate vestibule bymaintaining positive air balance, i.e., supplying air without taking return air back.M. External (Perimeter Stairs)Provide a thermostatically-controlled heating terminal unit to heat the stairs leading tooutdoors.N. General Waiting Areas (Admission and Radiology)Per CDC and ASHRAE requirements, all waiting areas shall be maintained under negative airbalance and exhausted outdoors at the rate <strong>of</strong> 12 air changes per hour. General exhaustsystem can be used to ventilate these spaces.O. Operating Rooms(1) GeneralProvide a dedicated 100% outside air (OSA) air-handling unit with 20 air changes (minimum)air to condition the surgery rooms and associated auxiliary spaces that will constitute asurgical suite. All air shall be exhausted outdoors and the space shall be maintained underpositive air balance.(2) Air DistributionProvide stainless steel supply air ductwork, 2 position terminal box with hot water reheat, andHEPA filter. Provide stainless steel supply and exhaust registers.(3) HumidifierProvide unit-mounted humidifier to maintain exhaust air at 46 °F [8 ˚C] dewpoint.(4) Temperature and Relative Humidity Trend LOG DataProvide capability <strong>of</strong> recording operating room temperature and humidity by DDC controls orby manual recorder.Part I: Basic Solicitation Requirements – Page 111 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY](5) Energy Conservation FeaturesProvide capability <strong>of</strong> reducing the supply and exhaust air volume by 50% while still maintainingthe positive air balance. Provide a variable speed drive for the supply and exhaust air fans tooperate at the reduced air volume and compensate for the variation in the static pressure dueto filter loading.6.5 FIRE PROTECTION6.5.1 FIRE EXTINGUISHERSPortable fire extinguishers recessed in cabinets shall be provided, inspected, and maintainedby the Lessor in accordance with National Fire Protection Association (NFPA) 10, Standard forPortable Fire Extinguishers.Recessed cabinets shall be provided in occupied areas. Size fire extinguisher cabinets toaccommodate a 2.5 gallon [9.5 liters] pressurized water extinguisher. Recessed cabinets shallbe conspicuously marked.//Locate additional fire extinguisher cabinets in the surgical suite and in elevator machinerooms.//6.5.2 FIXED FIRE EXTINGUISHING SYSTEMSProvide fixed fire extinguishing systems in accordance with NFPA 96 for cooking operationsproducing grease laden vapors or smoke.Fixed fire extinguishing systems shall be wet chemical and shall comply with UL300 inaccordance with NFPA 17A. Activation <strong>of</strong> the fixed fire extinguishing system shall shut downthe power/fuel source to the cooking equipment and shall be connected to the fire alarmsystem.6.5.3 AUTOMATIC SPRINKLER //AND STANDPIPE// SYSTEMSAutomatic sprinkler systems shall be installed in the outpatient clinic building and anyaccessory buildings. Installation shall comply with NFPA 13. Sprinklers shall be installedthroughout the building(s), including elevator machine rooms, walk-in freezers and cold rooms,telecommunications rooms, radiology and MRI suites, loading docks, electrical rooms andclosets, audiometric booths, vaults, and generator rooms.Provide a standpipe system as required by locally adopted codes and standards, NFPA 45,NFPA 1, or NFPA 101.A. DesignThe design shall comply with the requirements <strong>of</strong> NFPA 13// and NFPA 14//. The automaticsprinkler system shall be hydraulically designed by any design approach allowed by NFPA 13.A minimum safety factor <strong>of</strong> 10% shall be provided in the hydraulic calculations. Pipe schedulesystems may be used for extension <strong>of</strong> existing pipe schedule systems where water supply isadequate. Sprinkler systems shall be designed based on available water supply without firepump operating, where possible.Part I: Basic Solicitation Requirements – Page 112 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]B. InstallationThe installation shall comply with the requirements <strong>of</strong> NFPA 13// and NFPA 14//. Sprinklersshall be provided throughout the building.// Standpipes shall be Class I hose connections.////Where necessary, provide a fire pump to supplement the fire flow and pressure. Theinstallation <strong>of</strong> the fire pump shall comply with the requirements <strong>of</strong> NFPA 20. The fire pumpshall be an electric motor driven, horizontal split case centrifugal type. The fire pump shall beprovided with both a test header and flowmeter. Relief valves, if provided, shall berecirculated back to the suction side <strong>of</strong> the pump. Jockey pumps shall be rated for no lessthan 60 GPM [3.79 L/s]. Fire pumps shall start automatically at 10 ppsi below the jockeypump start pressure. Fire pumps shall be manually shut down.//Design wet pipe sprinkler systems, unless installed in areas subject to freezing. Dry pendantor sidewall sprinklers are preferred in lieu <strong>of</strong> dry pipe or antifreeze systems. Propylene glycolshall be used should antifreeze systems need to be installed when permitted by localauthorities. Do not use pre-action type systems.Sprinkler densities shall comply with NFPA 13, except in rooms containing movable/mobileshelving (high density storage) where the density shall be Ordinary Hazard (Group 2).Rooms containing bulk supply storage shall be classified as defined by NFPA 13. Do not useshelving which obstructs sprinkler water from penetrating down through racks.Install quick response sprinklers (QRS) in all areas, except where specifically prohibited (e.g.,high temperature areas as defined in NFPA 13, elevator shafts, or elevator machine rooms).On retr<strong>of</strong>it projects, replace existing standard sprinklers with QRS.Install standard sprinklers with intermediate temperature rating 200 F [93 C] or higher inelevator shafts, elevator pits, and elevator machine rooms. Install sprinklers in elevator shaftsand pits only where required by NFPA 13. (Comply with necessary power shutdownrequirements.)The installation <strong>of</strong> flow control (on/<strong>of</strong>f) sprinkler heads is not permitted.Provide non-ferrous piping for all areas within Magnetic Resonance Imaging (MRI) suites.Coordinate with architectural, mechanical and electrical work and show smoke zoneboundaries, hazard classification, density, and other special requirements on drawings.Coordinate sprinkler zones with fire or smoke (compartments) and fire alarm evacuationzones. Provide a flow switch, isolation valve, tamper switch, and pressure gauge for eachzone. Notification shall comply with NFPA 72.Determine and identify on drawings the location <strong>of</strong> fire pump, risers, all valves, fire departmentconnections, drains, and points <strong>of</strong> connection with underground fire service main.//Provide seismic protection in areas <strong>of</strong> Moderate High, High, and Very High Seismicities (SeeVA Seismic Design Requirements (H-18-8), Table 4).//C. CommissioningFor the leased facilities, commissioning <strong>of</strong> the fire protection systems shall be implemented toverify the intent <strong>of</strong> the design by inspecting and testing the systems.Part I: Basic Solicitation Requirements – Page 113 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]6.6 PLUMBING6.6.1 GENERALThe Lessor and the Lessor’s Design Engineer (henceforth known as the A/E or Engineer) shalluse the contents <strong>of</strong> this document to design, install, test, adjust, balance, and commission thePlumbing systems in a trouble-free working manner to provide comfort and safety to theveterans, staff, and visitors.6.6.2 MANDATORY PROVISIONSSee Paragraphs 4.1 CODES and 4.2.1 VA ADOPTED CODES, STANDARDS, ANDEXECUTIVE ORDERS.6.6.3 APPLICABLE CODES AND CRITERIASee Paragraph 4.1 CODES, for applicable codes and standards.6.6.4 PLUMBING DESIGN SCOPEThe plumbing design scope includes the following systems, which are detailed following thislist.A. Water Distribution SystemB. //Potable Water Treatment Systems (includes s<strong>of</strong>tening, reverse osmosis, de-alkalizing,deionization, and reagent grade water production)//C. Domestic Hot Water System, including RecirculationD. //Steam System//E. Sewer/Vent/Waste System inside buildingsF. Ro<strong>of</strong> Drainage SystemG. //Sub Soil Drainage System//H. //Interior Fuel Gas System//I. //Medical Gas and Vacuum System//J. //Dental Gas and Oral Evacuation System//K. //Laboratory/Shop Compressed Air System//L. //Acid Waste and Vent System//M. Seismic Restraint SystemN. Legionella MitigationA. Water Distribution SystemSize the piping for the hot and cold water systems per criteria specified in the IPC includingbackflow preventers, water hammer arrestors, and trap primers. Minimum pipe size shall be¾".Provide wall hydrants (a maximum <strong>of</strong> 200 feet [60.96 m] apart at the building exteriorperimeter) at loading docks and at building entrances, with a minimum <strong>of</strong> one wall hydrant oneach exterior wall.Maintain a minimum pressure <strong>of</strong> 35 PSI [240 kPa] at the plumbing fixtures on the top floor. Inminimum pressure calculations, use residual pressure at design flow. Monitor for diurnalpressure fluctuations experienced by the building water supply and modify starting pressuresaccordingly. Provide a pressure gauge on the top floor branch adjacent to the riser.Part I: Basic Solicitation Requirements – Page 114 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Where required, provide a domestic water booster system. Use a three-pump system witheach pump handling half <strong>of</strong> the design flow rate. An inlet and discharge potable water bladdertype buffer tank shall be provided to absorb pressure fluctuations and minimize pump cycling.Discharge pressure shall be controlled using variable frequency drives through a packagedbooster pump controller. Provide spring loaded swing check valves on the pump discharge.Provide a solenoid valve on the cold water supply to the dental Utility Junction Centers (UJC)with a control switch located in the reception area. A UJC is a grouping <strong>of</strong> specific utilitiesbrought to a designated location in each dental operatory to provide convenient points <strong>of</strong>connection to the dental operating unit equipment.The electrical supply shall be coordinated with the electrical engineer for all electronic faucetsand flush valves, trap primers, solenoid valves, pumps, alarm panels, hot water heaters, andother appliances and equipment requiring electrical power.B. Potable and Special Water Treatment SystemsPotable water provided to VA shall meet minimal EPA and/or state standards forcontaminants. If potable water does not meet EPA and/or state standards, Lessor shall takeaction necessary to reduce contamination to acceptable levels. Lessor shall test potablewater periodically to ensure that it continues to meet EPA and state standards.Provide water treatment as required to meet EPA and/or state drinking water standards, andto meet special water use needs.(1) Water S<strong>of</strong>tenerProvide vertical, pressure type, sodium cycle water s<strong>of</strong>teners from a single vendor.Regeneration shall occur no more than once per day. Provide bypass. A water s<strong>of</strong>tenersystem is required under the following conditions:Entire Clinic: Provide 100% duplex s<strong>of</strong>tening equipment (with hard water bypass) when totalhardness exceeds 170 ppm (mg/L) as CaCO3. Blend equipment effluent to a hardness <strong>of</strong>approximately 50 ppm [mg/L]. Provide a ventilated salt storage room to store a 30 day supply<strong>of</strong> salt.Steam Cooking Equipment: Provide a simplex s<strong>of</strong>tener system when total hardness exceeds5 ppm [mg/L].Pretreatment: Provide 100% duplex s<strong>of</strong>tening equipment (with hard water bypass) forReverse Osmosis and Hemodialysis water treatment packages.Boiler Feed-water Make-up Use: Design duplex s<strong>of</strong>teners, each furnishing 100% <strong>of</strong> themaximum flow rate, at an exchange capacity required for peak boiler feed-water make-up.(2) Reverse OsmosisProvide a stand-alone reverse osmosis system, comprised <strong>of</strong> a factory assembled package,complete with dual alternating carbon filters with automatic backwash, a 20 and 5 micron prefilter,a reverse osmosis membrane, pressure pump, and all valves and controls necessary forcomplete automatic operation. All parts and components to be compatible with EPA drinkingwater standards, and the entire package shall be UL listed.Part I: Basic Solicitation Requirements – Page 115 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY](3) Dealkalizing SystemAs facility needs dictate, provide a single chloride-anion pressure-type water-dealkalizingsystem for boiler feed-water make-up to follow water s<strong>of</strong>tening equipment. Reduce alkalinityto 20 ppm [mg/L]. Provide s<strong>of</strong>t water bypass.Design a separate measuring tank <strong>of</strong> sufficient size to furnish amount <strong>of</strong> saturated salt andcaustic soda solution required for one regeneration. Caustic soda shall be approximately 10%by weight <strong>of</strong> total solution. Designate interior floor space for caustic storage.(4) Deionization SystemAs facility needs dictate, provide a three-bed deionizer (cation, anion, mixed bed) <strong>of</strong> the tankexchange type, providing de-ionized water to meet the requirements <strong>of</strong> the facility. Feedwaterto the deionizer system shall be fed through a 5 micron filter, provided as a component <strong>of</strong> thedeionization system. The system shall be factory assembled, full duplex, and designed forautomatic production <strong>of</strong> water with a conductivity <strong>of</strong> less than 10 micro-ohms.(5) Reagent Grade SystemAs facility needs dictate, provide a complete packaged reagent grade water system. Confirmif users require grade 1, 2, or 3 quality, and estimate consumption amounts. Evaluate if it iscost-effective to provide reagent grade water system, or to have the users purchase waterfrom an ISO3696: 1987-listed firm.C. Domestic Hot Water SystemEvaluate whether a central hot water system or stand-alone hot water heaters are bettersuited to the project. Analyze the various options in providing domestic hot water, and complywith pertinent sections <strong>of</strong> ASHRAE 90.1-2007 for water heating equipment efficiencies andpipe insulation.If a central system is provided, evaluate whether it should be dedicated to domestic hot water,or if it should be a part <strong>of</strong> the central steam plant. Coordinate this design with the facilityrequirements, as steam requirements for sterilizers and humidifiers may be significant.Provide recirculation pump per IPC.(1) Stand-Alone Hot WaterProvide gas (or electric if gas not available) storage tank type water heater(s), sized perASPE. Provide drain pan, pressure/temperature relief valve, flue, and combustion air per IPCand local codes.(2) Central Storage Tank SystemProvide gas (or electric if gas not available) central storage tank hot water system, sized perASPE. Water heater discharge temperature shall be set at 130 ˚F [54 ˚C]. Providetemperature limiting valve set at 105 ˚F [41 ˚C] at all shower heads. Providepressure/temperature relief valve, flue, and combustion air per IPC and local codes.D. //Steam SystemEvaluate whether a central steam plant is justifiable. If the facility requires significantquantities <strong>of</strong> steam for sterilizers and/or humidifiers, it may well result in the lowest first andoperating costs to combine these systems with domestic hot water. If so, provide shell (tank)and steam tube bundle for domestic hot water use, with hot water discharge temperature setat 140 ˚F [60 ˚C]. Provide pressure/temperature relief valve, condensate piping, and steamvalve train, complete with bucket traps, control valve, and isolation valves.//Part I: Basic Solicitation Requirements – Page 116 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]E. Sewer/Vent/Waste Systems Inside BuildingDesign sewer/vent/waste systems in accordance with IPC and ASPE. "Sovent" combinationwaste and vent systems are not allowed.Unless required by local codes, floor drains shall not be installed in private or individual toiletrooms with a single water closet. Provide floor drains with trap primers in public toilet roomscontaining two or more water closets, or a combination <strong>of</strong> one or more water closets and oneor more urinals. Floor drains are required in bathrooms with showers.Provide cleanouts according to the IPC. Identify all cleanouts on plans and riser diagrams.Do not locate cleanouts above ceilings or crawl spaces, and provide additional cleanout at the"end <strong>of</strong> run" <strong>of</strong> all groups <strong>of</strong> fixtures. Wherever possible, extend cleanout to outside thebuilding perimeter.F. Ro<strong>of</strong> Drainage SystemRo<strong>of</strong> drains shall be sized per IPC with applicable local amendments. In locations where theASHRAE winter 1% dry bulb temperature is below 32 °F [0 ˚C], insulate ro<strong>of</strong> drain leaderslocated under the ro<strong>of</strong> and above lay-in or hard ceilings. Coordinate connection <strong>of</strong> ro<strong>of</strong>drainage piping to storm drain site piping. Point <strong>of</strong> connection <strong>of</strong> building ro<strong>of</strong> drain piping tosite piping is at 5’-0" outside the building perimeter.G. //Sub-Soil Drainage PipingSub-soil drainage piping for building structure is the responsibility <strong>of</strong> the site civil engineer.//H. //Interior Fuel Gas SystemDesign in accordance with NFPA 54 or IFGC, as required and as modified by local codes.//Provide natural gas earthquake valve downstream <strong>of</strong> and adjacent to the main gas meter at alllocations within a seismicity rating <strong>of</strong> moderate-high, high, or very high, as indicated within VASeismic Design Requirements Publication No. H-18-8.Provide solenoid valve in the natural gas supply link to the Dental Laboratory and the DentalClinic Operatories, with an emergency shut-<strong>of</strong>f manual valve for each area (accessible to theusers) located at the exit door to the space.I. //Medical Gas and Vacuum SystemsProvide medical gas and vacuum wall connections at locations as dictated by the facilityrequirements, and design oxygen, medical air, vacuum, and other gas systems in accordancewith NFPA 55, NFPA 99, as modified by local codes, and as specified in this document.Medical air and vacuum systems shall be isolated from Dental Compressed Air and OralEvacuation systems. Provide combined zone valves (oxygen, medical air, and vacuum) innurse station or other appropriate and coordinated area.Oxygen and Medical Air systems shall be designed to deliver 50 PSI, with piping system not toexceed a 5 PSI loss from source to point <strong>of</strong> use. Minimum design flow rate for any pipesection is 7 SCFM. Medical air system compressor shall be <strong>of</strong> duplex design, 100%redundant with a single receiver.Vacuum system shall be designed at 15 inches Hg, with piping system not to exceed 3 inchesHg pressure drop from source to point <strong>of</strong> use. Minimum design flow rate for any pipe sectionis 4.0 SCFM.Part I: Basic Solicitation Requirements – Page 117 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Note: Medical gas and vacuum systems as specified above are minimums. Systems may beconsiderably more complex based upon facility requirements.//J. //Dental Gas and Oral Evacuation SystemsSystems provide dental gas and oral evacuation connections at locations dictated by thefacility requirements, and design oxygen, compressed air, oral evacuation system and othergas systems in accordance with NFPA 55, NFPA 99, as modified by local codes and asspecified in this document. Dental compressed air and oral evacuation systems shall beisolated from medical air and vacuum systems. Provide combined zone vales (oxygen anddental compressed air) in receptionist area or other appropriate and coordinated areas.Oxygen system shall be designed to deliver 50 PSI, with piping system not to exceed a 5 PSIloss from source to point <strong>of</strong> use. Minimum design flow rate for any pipe section is 7 SCFM.Dental compressed air system shall be designed to deliver the regulated 100 PSI, with pipingsystem not to exceed 5 PSI loss from source to point <strong>of</strong> use. Minimum design flow rate forany pipe section is 7 SCFM. Dental compressed air system shall be duplex, with a singlereceiver.The Dental Oral Evacuation System is comprised <strong>of</strong> central vacuum system providing suctionto a Saliva Ejector (SE) and a High Volume Evacuator (HVE). The central vacuum systemshall be designed to maintain a vacuum <strong>of</strong> 8" Hg, using an alternating duplex vacuumproducer, each carrying 70% <strong>of</strong> the load. Provide with solids separator, and dischargeexhaust pipe through ro<strong>of</strong> <strong>of</strong> portion <strong>of</strong> building in which located. SE piping shall be providedin each operatory. Locate HVE system outlets in floor mounted UJC.//K. //Laboratory/Shop Compressed Air SystemsProvide simplex air compressor to serve equipment and a minimum <strong>of</strong> one outlet on each wallin shop areas. The shop compressed air system shall include intake silencer, filter,refrigerated dryer, and receiver. Interior outlets shall be no farther apart than 25 feet[7.62 meters].//L. //Acid Waste and Vent SystemsProvide chemical-resistant pipe for all waste and vent piping serving laboratory fixtures andphotographic developing equipment. When fusion-joined plastic piping systems are used,mechanical joints shall be installed at traps and trap arms for maintenance reasons. Chemicaldrainage shall pass through an acid-neutralizing tank before connecting to the buildingsanitary drainage system. Install chemical-resistant vent pipe independently through thero<strong>of</strong>.//M. Seismic Restraint SystemsEarthquake-resistive design for plumbing equipment and piping shall comply with therequirements <strong>of</strong> VA Seismic Design Requirements Publication No. H-18-8 and theInternational Building Code (IBC).Exceptions: When allowed by local code, seismic restraint may be omitted for the followinginstallations:Gas and medical air piping less than 1 inch [25 mm] inside diameter.Piping in boiler and mechanical equipment rooms less than 1¼ inch [32 mm].All other piping not including gas and medical air less than 2½ inch [64 mm].Part I: Basic Solicitation Requirements – Page 118 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Equipment weighing less than 400 pounds [180 kg] support and attached directly onthe floor.Equipment weighing less than 50 pounds [9 kg] suspended from the ro<strong>of</strong> or floor orhung/supported from the wall.N. Legionella MitigationThere are currently no EPA enforceable regulations governing the levels <strong>of</strong> Legionella bacteriain potable water systems; however, EPA has issued a Maximum Contaminant Level Goal(MCLG) <strong>of</strong> 0 ppm [mg/L]. Municipal water supplies and wells can carry Legionella, so it is agiven that the bacteria will be introduced into the facility potable water system at some time.The challenge is to limit the amplification <strong>of</strong> the bacteria to less than lethal levels.Legionella bacterial amplification occurs when bio-films exist in water storage tanks and deadendpiping legs which allow for growth sites, and when temperature and pH levels areoptimum for growth. Infection can occur when patients inhale atomized droplets whileshowering, drinking or receiving respiratory treatment.(1) Piping DesignProvide means to easily remove and disinfect all outlet devices such as showerheads andfaucets, etc. Utilize self-draining showerheads.Provide a ¾" ball valve at the end <strong>of</strong> each piping section as a means to drain heated (above140 °F [60 ˚C]) flushing hot water that will be used for initial and supplemental disinfection.Ball valve shall be within 50 feet [15.24 meters] <strong>of</strong> a floor sink, floor drain, sink, or lavatory.Mix hot/cold water as near the showerhead as possible.Eliminate all dead legs in the piping system.Design domestic water piping system to facilitate future installation <strong>of</strong> a copper-silver iongenerator system.(2) Disinfection MethodsSubsequent to piping disinfection required per IPC, and as part <strong>of</strong> the commissioning process,disinfect the potable water systems against Legionella by one <strong>of</strong> the following methods:Thermal Eradication: Flush 145°F water through all outlets for a period <strong>of</strong> at least30 minutes.Chlorine: Flush free chlorine at a level <strong>of</strong> 2 parts per million (PPM) or greater for aperiod <strong>of</strong> at least 2 hours.Further information can be found in ASHRAE paper CH-03-3-2.O. Plumbing System CommissioningRefer to 4.8 SUSTAINABLE DESIGN AND ENERGY EFFICIENCY.6.6.5 PLUMBING FIXTURES, TRIM AND EQUIPMENTProvide plumbing fixtures, trim and equipment as required by the IPC.Part I: Basic Solicitation Requirements – Page 119 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]A. Plumbing FixturesWater closets, urinals, sinks and lavatories shall be vitreous china or stainless steel. Bariatricwater closets shall be rated at 1,000 pound [454 kg] capacity. Waterless urinals are notpermitted. Service sinks (mop sink/basin) shall be floor-mounted cast terrazzo, (a combination<strong>of</strong> Portland cement and grey marble chips).B. Plumbing TrimFaucets and showerheads shall be <strong>of</strong> chromed brass, monel, or stainless steel; plastic trim isnot permitted. Faucets shall be laminar flow; aerators are not permitted. Electronic handsfreecontrols shall be provided at all hand washing sinks and lavatories.C. Plumbing EquipmentProvide wall-hung, self-contained, electric wheelchair accessible water cooler.Hot water re-circulation pump shall be all bronze, with timer based controls.6.7 ELECTRICAL6.7.1 GENERALThe Lessor shall provide all the necessary electrical facilities for the project. It is expected thatelectrical systems will meet their primary objective <strong>of</strong> providing appropriate and reliable interiorand exterior electrical, lighting, and auxiliary systems and services necessary to the safety andcomfort to the veterans, employees, and visitors. In addition, the systems shall be safe, easilyaccessible for repairs and maintenance, and energy-efficient.6.7.2 CALCULATIONSPrepare and submit calculations as required by the type <strong>of</strong> design work performed.Calculations shall justify lighting designs; size <strong>of</strong> each branch circuit and feeder conductor,overcurrent protective device, equipment bus, generator, transformer, etc., at all voltagelevels; setting <strong>of</strong> each overcurrent protective device with adjustable characteristic; requiredPPE to meet arc flash energy levels; etc. The Lessor shall submit the following calculations toVA: fault current calculations, protective device coordination study, arc flash calculations, loadcalculations, generator-set sizing calculations, voltage drop calculations, lightning protectionsystem risk analysis, and lighting calculations.6.7.3 LIGHTING CALCULATIONSPerform all lighting calculations based on illumination criteria per the IESNA LightingHandbook, latest edition. Calculations shall include room name, room number, fixture typechosen for the room, number and type <strong>of</strong> lamps to be used in the room, required illuminationlevel, calculated illumination level, and all assumptions used.Calculations for most interior spaces may be performed using the zonal cavity method.Perform and submit point-by-point calculations for areas <strong>of</strong> greater architectural or luminoussophistication. Calculations for exterior spaces, including parking structures, shall be point bypoint. Calculations shall demonstrate compliance with energy requirements per Paragraph 4.8SUSTAINABLE DESIGN AND ENERGY EFFICIENCY.Part I: Basic Solicitation Requirements – Page 120 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]6.7.4 FIRE ALARM SYSTEMSFire alarm systems shall be provided as required by NFPA 101 or the locally adopted codes.The fire alarm system shall be designed to meet the requirements <strong>of</strong> NFPA 72 and the localcodes.//For new installations, locate the fire alarm control panel at the main entrance or at a 24-hourconstantly attended location.New fire alarm systems shall be analog addressable.//Fire alarm systems shall not be combined with other systems such as building automation,energy management, security, etc.Wiring for fire alarm systems shall be as follows: Initiating Device Circuits – Style B (Class B),Signaling Line Circuits – Style 4.0 (Class B), Notification Appliance Circuits – Style Y (ClassB), and Communications between fire alarm control units – Style 7 (Class A). Where there areconflicts with local codes, the most stringent requirements shall be enforced.Initiation devices shall be provided in accordance with NFPA 101, NFPA 72, NFPA 90A, andASME 17.1 or ASME 17.3, as applicable.Audible fire alarm notification appliances shall be provided in accordance with NFPA 72 andNFPA 101.Visual fire alarm notification appliances shall be provided in mechanical rooms, publicrestrooms, public accessible areas such as corridors, auditoriums, cafeterias, assemblyrooms, canteens, retail stores, and other publically accessible rooms <strong>of</strong> more than 750 squarefeet [228.6 square meters] <strong>of</strong> area.Coordinate fire alarm zones with the location <strong>of</strong> smoke compartments and sprinkler zones.The fire alarm system shall be monitored by a listed remote central station.6.7.5 RACEWAYS AND WIRINGInstall all wiring in raceways. All wiring shall be copper. All circuits and branch circuits shallhave a separate equipment grounding conductor <strong>of</strong> appropriate size per the NEC. No morethan 3 branch circuits are allowed to run in one homerun.6.7.6 LIGHTNING PROTECTION SYSTEMPerform risk analysis per NFPA 780, Annex L and provide a lightning protection system,where Nd>Nc. Submit calculations, including all assumptions. The Lessor shall use thefollowing fixed factors in the calculation: C 3 = 2.0, C 4 = 1.0, C 5 = 5.0. All other factors shall beproject-specific.6.7.7 RECEPTACLE CIRCUITSNo more than 6 receptacles shall be installed on a single circuit.Part I: Basic Solicitation Requirements – Page 121 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]6.7.8 //ESSENTIAL ELECTRICAL SYSTEM FOR CLINICSThe Essential Electrical System (EES) for other health care facilities shall comply with theType 3 system as defined in NFPA 99, shall supply loads as defined in NFPA 70 and 99, andshall comply with the Joint Commission testing and reporting requirements. The Type 3Essential Electrical System shall supply power for the task illumination and limited powerservice that is related to the safety <strong>of</strong> life, and that is necessary for the safe cessation <strong>of</strong>procedures in progress. The alternate source <strong>of</strong> power shall be per NFPA 70 and 99.If electrical life support equipment is required or critical care areas are present in the facility,the Essential Electrical System shall comply with the Type 1 system as defined in NFPA 99. Ifa Type 1 system is required, connect the functions/items listed in Paragraph 6.7.9 to theEssential Electrical System.//6.7.9 //ESSENTIAL ELECTRICAL SYSTEMS FOR CLINICS WITH ELECTRICAL LIFESUPPORT EQUIPMENT OR WHERE CRITICAL AREAS ARE PRESENTThe Essential Electrical System for clinics with electrical life support or where critical areas arepresent shall comply with the Type 1 system as defined in NFPA 99.A. Emergency SystemThe Emergency System shall comply with NFPA 70 and 99.B. Life Safety BranchThe Life Safety Branch shall supply power to loads per NFPA 70 and 99, including:Alarm and alerting systems, such as fire alarm and medical gas systems.Automatic doors, used for building egress.Elevator cab lighting, control, communication, and signal systems.Exit signs. Generator set location: task illumination, battery charger for emergency batterypoweredlighting units and selected receptacles.Illumination <strong>of</strong> means <strong>of</strong> egress.Telecommunications systems, where used for issuing instructions during emergencyconditions, including public address and Code One (Blue) systems.C. Critical BranchThe Critical Branch shall supply power to loads per NFPA 70 and 99, and as described below:Emergency Room Treatment Areas and Life Support Rooms: Task illuminationand PBPUs.Hemodialysis Rooms: Task illumination and one receptacle for each dialysis unitPBPU.Part I: Basic Solicitation Requirements – Page 122 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Human Physiology Labs: Task illumination, selected receptacles and selectedcircuits.Medication Rooms and Medication Preparation Areas: Task illumination, selectedreceptacles and refrigerators.Minor Operating Rooms: Task illumination and selected receptacles.Nurse Call Systems.Nurses’ Stations: Task illumination and selected receptacles.Surgical Operating Rooms: Task illumination (50% <strong>of</strong> the general fluorescentfixtures above the surgery table including battery backup within two <strong>of</strong> these fixtures),each x-ray unit and one film processor per suite.Surgical Recovery Rooms: Lighting fixture over each bed, one receptacle for eachbed (or PBPU), night lights for each bed (or PBPU), and emergency alarm circuits.Main Computer Room, Telephone Equipment Room, Telephone Console Room,Head End Room, and/or Telecommunications Rooms: All UPS equipment, lighting,and receptacles.Dental Suites: Each ceiling track operatory surgical light, each dental operating unit,one duplex receptacle in each treatment area, and a storage refrigerator.Electrical Rooms: 50% <strong>of</strong> lighting and 50% <strong>of</strong> receptacles. Also, provide additionalbattery-powered lighting main electrical room.Mechanical Equipment Rooms: UPS equipment, task illumination, and selectedreceptacles for operating and controlling internal auxiliary power, data gatheringpanels, control air compressors, dryers, and any electric control for heating,ventilating, and air-conditioning (HVAC) systems.Pharmacy Delivery Systems and Delivery Areas: Task illumination, selectedreceptacles.Pharmacy Dispensing Area: Power files, laminar flow hoods, refrigerators, copier fortransmittal <strong>of</strong> physicians' orders, task illumination, and selected receptacles.Security Station: Monitoring security alarm systems, task illumination, andreceptacles.Radiology: Task illumination and x-ray unit.HVAC for Surgical Suites and Emergency Treatment Spaces, and other areas asdeemed necessary by VA.Medical dispensing equipment.Part I: Basic Solicitation Requirements – Page 123 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]D. Equipment BranchThe Equipment Branch shall supply power to loads per NFPA 70 and 99.(1) Equipment Branch Non-Delayed Automatic ConnectionArrange the following generator accessories for non-delayed automatic connection to thealternate power source:Electrically operated louversOther generator accessories essential for generator operationTransfer fuel pump(2) Equipment Branch Delayed-Automatic ConnectionArrange the following equipment for delayed-automatic connection to the alternate powersource, including necessary controls:Vacuum pumps and oral evacuation pumps serving medical and surgical functions,including controls. Sump pumps and other equipment required to operate for the safety <strong>of</strong> majorapparatus, including associated control systems and alarms.Medical and dental air compressors, serving medical and surgical functions, includingcontrols (such systems may be connected to the Critical Branch).Smoke control and stair pressurization.Uninterruptible Power Supply (UPS) equipment serving equipment other thantelecommunications equipment.Medical and laboratory refrigerators and freezers as required.Oxygen storage control panel.Equipment and control systems for each elevator bank: Design control systems tooperate at least one elevator at a time and designate one elevator to serve theSurgical Suite during emergencies.Fire pump, jockey pump, and make-up pump for water-based fire protection systems;lighting and selected receptacles in fire pump room.Automatic operated doors.Autoclaving equipment (shall be permitted to be arranged for either delayed-automaticor manual connection to the alternate source).Domestic Water Pumps: Equipment, control system, light fixture and receptacle nearthe pump.Electric tape for heat tracing piping requiring freeze protection.Part I: Basic Solicitation Requirements – Page 124 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Heating, ventilating, and air-conditioning (HVAC) systems.Heating and Cooling Equipment for Operating Suites, Recovery, and EmergencyTreatment Spaces.oHVAC equipment for Magnetic Resonance Imaging (MRI) Suites andComputerized Topographic (CT) Scanners.o HVAC equipment for Main Computer Room, Telephone Equipment Room,Telephone Console Room, Head End Room, and TelecommunicationsRooms.Ventilation, cooling and control equipment for elevator machine rooms, where theelevator(s) is backed by generator power.Hot Water Generator: Equipment, controls, and light fixture and receptacle near thegenerator.Refrigerated Medical Storage: Refrigeration equipment.Sewage Pumps: Equipment, controls, and light fixture and receptacle near thepumps.Supply, Processing, and Distribution (SPD):oooTask illumination and selected receptacles in the following areas: core, sterilestorage, non-sterile storage, preparation, and decontamination.One ultrasonic cleaner, one ethylene oxide gas sterilizer, one steam sterilizer,one washer sterilizer, and one gas generator.Equipment needed to preserve subsistence drugs that may be subjected todamage from infestation, humidity, or temperature.//E. Alternate Source <strong>of</strong> Power (Type 1 EES)The alternate source <strong>of</strong> power shall be one or more diesel engine-driven generator sets.Provide fuel supply for 24 hours <strong>of</strong> operation. Locate exhausts such that exhaust gases arenot entrained into the building air. Fuel tank(s) shall have leak detection means. Offeror shallbe responsible for corrective actions and remediation in the event <strong>of</strong> a tank malfunction or aviolation <strong>of</strong> EPA or local regulations. Offeror shall license or register tanks as required by EPAor local Authorities Having Jurisdiction.6.7.10 POWER MONITORING AND METERINGPower monitoring and metering are required to support energy use and conservations goals.6.7.11 ELECTRICAL ROOMS AND CLOSETS:No telecommunications equipment, other than telecommunications outlets, shall be placedwithin electrical rooms. Provide appropriate construction for the type <strong>of</strong> transformer(s)Part I: Basic Solicitation Requirements – Page 125 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]installed. Electrical closets shall stack vertically, and shall not be further than 150 feet[45.72 m] apart, to limit maximum 120V circuit length to approximately 75 feet [22.86 m].Rooms that contain freestanding electrical equipment shall be sized so that sufficient space isprovided to add one additional section to each unit <strong>of</strong> freestanding equipment. Provideextended pad space and spare conduits that will facilitate future installation <strong>of</strong> equipment andconductors. Spare space shall be indicated on drawings.6.7.12 ELECTRICAL EQUIPMENTElectrical distribution components shall have copper bussing. Each panelboard shall contain25% spare breakers.6.7.13 LIGHTING FIXTURESStandardize lamp types across fixture types to limit the number <strong>of</strong> different lamp types andwattages used. Select the number <strong>of</strong> lamps and the fixture type according to therecommended finishes specified in each area to ensure the intended lighting levels.Linear 2-foot and 4-foot T8 fluorescent lamps with CRI>70 and rated lifespan <strong>of</strong> 20,000 hoursare the preferred interior lighting source. T5 2-foot and 4-foot double-ended linear sources areallowed for indoor locations. Compact fluorescent lamps in twin-, tri-, and quad-tube T4configurations are allowed.Color-corrected lamps, having a CRI <strong>of</strong> 85 or above and correlated color temperature between5000 degrees K and 6000 degrees K, are required in recovery rooms, operating rooms (colorshall match that <strong>of</strong> the surgical light), and dental rooms (examination, oral hygiene, oralsurgery, recovery, labs, treatment, and x-ray).Select fixtures and light sources with long operating lives; which utilize controlling elements(lenses, louvers, reflectors, etc.) designed to provide the best utilization <strong>of</strong> emitted light at thetask location; that are appropriate for the ambient temperature; and that are not prone to dirtaccumulation. In high ceiling areas, locate fixtures for maintenance access or provide accessfor maintenance equipment.Exterior lighting shall comply with energy requirements, and should comply with Dark Skyprinciples. When required by VA, exterior lighting designs are to meet the requirements <strong>of</strong>local outdoor lighting codes. Criteria recommended in the IESNA Guideline for SecurityLighting for People, Property, and Public Spaces (latest edition) shall govern the lightingdesign. Exterior lighting shall be coordinated with physical security, SSTV, and landscapingrequirements.6.7.14 BALLASTSElectronic high-frequency type ballasts shall be used for all linear fluorescent lamps, unlessspecial environmental and/or sensitive equipment concerns require the use <strong>of</strong> low-frequencyhybrid electronic-electromagnetic ballasts that operate lamps at 60Hz. Hybrid electronicelectromagneticballasts are allowed for surgical rooms and critical care units, as deemedappropriate by the design A/E. For metal halide, use pulse-start ballasts, and pulse-startlamps with glass or ceramic arc tubes. Probe-start ballasts and lamps are not acceptable.Part I: Basic Solicitation Requirements – Page 126 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]6.7.15 LIGHTING CONTROLEnergy consumption constraints dictate the installation <strong>of</strong> automatic lighting controls for bothinterior and exterior lighting. Select and design master and room-specific lighting controlsystems that comply with energy codes and requirements; that respond to daylight harvesting;that utilize the correct sensor and sensor location for the controlled space; that are compatiblewith the controlled ballasts and lamps; and that are responsive to the occupant’s desire not t<strong>of</strong>eel "over-controlled."6.8 TELECOMMUNICATIONS6.8.1 TELECOMMUNICATIONS: CABLE PATHWAYS, WIRING, CABLES, ANDINFRASTRUCTURE PLANT; AND SPECIAL TELECOMMUNICATIONS SYSTEMSA. ScopeThis section covers requirements for cable pathways and raceways, fiber optic and copperwiring and cables, and special telecommunications systems (hereinafter referred to as"Special Systems"). Special Systems are identified as those telecommunications systems thatare not telephone, data, or fire alarm (or related functions).Cable pathways, wiring, and cables (both copper and fiber optic) make up theTelecommunications Infrastructure Plant (TIP) for the telephone, data, and Special Systems.B. General RequirementsAll TIP wire and cabling shall be installed in drop ceiling using cable hangers and a wirebasket cable tray. In hard ceiling areas, a raceway system, which may consist <strong>of</strong> a mixture <strong>of</strong>conduits and enclosed cable trays, is required.TIP wires or cables may be provided inside gypboard walls in flexible conduit, or withoutconduit, as specifically approved by VA in writing for each specific location.The term "provide," where used herein, shall mean the same as "designed, engineered,furnished, installed, tested, guaranteed, and certified."A complete and functional telecommunications infrastructure plant (TIP) is required. Inrenovation projects, the TIP shall be compatible with the facility’s existing TIP. The TIP shallat a minimum incorporate all telephone, data, and Special Systems cables.C. Conduits and Boxes(1) GeneralFor system conduits, junction boxes, routing, termination, risers, horizontal runs, sizing, etc.,follow industry-standard requirements.(2) Minimum SizeConduit from outlet to above ceiling should be a minimum <strong>of</strong> one (1) inch.Conduit runs outside buildings will be equipped with a pull box (inside) or manhole (outside)after two 90-degree bends or an accumulation <strong>of</strong> 120-degrees <strong>of</strong> total pathway deviations froma straight line between each point <strong>of</strong> access.Part I: Basic Solicitation Requirements – Page 127 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Conduits outside <strong>of</strong> buildings shall be waterpro<strong>of</strong> and shall not exceed 400 feet [122 meters]between manholes or pull boxes (not counting bend or traverse loss).(3) Interconnecting Conduit RequirementsThe following table identifies the minimum conduit requirements for the telecommunicationsand special systems infrastructure (not all conduits may be required, depending on roomsprovided):Conduit RequirementsLocation A Location B ConduitTypeEntrance from street TER Direct burialPVC or PEQuantityTER MCR EMT 4StackedTelecommunicationsRooms (TR)MCR (Optional)Size4 4 inch[100 mm]Next Stacked TR Sleeve 4-6 4 inch[100 mm]Each TR VerticalRiser StackEMT 4 4 inch[100 mm]Between TRs on samefloorBetween TRs onsame floorEMT CableTray12 inch[305 mm]MCR (Optional) PCR EMT 1 4 inch[100 mm]HE Room (Optional) Ro<strong>of</strong> or access toantennasEMT 2 3 inch[75 mm](4) Horizontal ConduitsBasket type cable tray may be installed above suspended ceilings in corridors for stationwiring in non-critical areas. Minimum size shall be 12 in [305 mm] wide with 2 in [50 mm]sidewalls.Surface metal raceways are not acceptable and will not be approved for wire or cable on theoutside <strong>of</strong> walls.Provide cable radius drop fittings (aka waterfalls) where cables exit basket type cable tray.(5) Vertical RisersProvide conduits <strong>of</strong> the size and counts depicted in the Conduit Requirements table in eachTR as shown. Also, ensure each floor and ceiling penetration is sleeved and thecorresponding conduit ends secured AFF and BFC, as described herein. Seal each conduitand associated cable with fire-pro<strong>of</strong>ing compound. Also, ensure each empty conduitpenetration is like sealed.(6) Telecommunications Cable Ducts Under Cellular FloorsUnderfloor ducts and/or cellular floors shall be considered as air plenum areas. Therefore, allsystem wires and cables provided in these areas shall be plenum-rated and installedaccordingly.Each underfloor cable duct and/or cellular floor installation shall be provided with appropriatewire management system(s).Part I: Basic Solicitation Requirements – Page 128 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]D. Telecommunications OutletsOutlet boxes shall be the same minimum size as NEC standard quadraplex (or dual duplex)electrical outlet boxes.Outlet boxes shall be equipped with full covered wall faceplates and two (2) each modularCategory Six RJ-45 jacks and contain enough space for two (2) each additional modularCategory Six RJ-45 jacks, one additional modular (1) stainless steel fiber-optic, and one (1)BNC (A/E note: an "F" type may be substituted "depending on system design) with analogcoax cable jacks (for a total <strong>of</strong> six available modular jack positions). For cable installed insystems furniture route cables through raceways internal to the furniture frame to the outlet ateach workstation.Unless otherwise specified, mounting heights for telecommunication outlets shall be:Telecommunications Outlets Mounting HeightAREA/FUNCTION MOUNTING REQUIREMENTSPay station4 ft [1,200 mm] above finishedfloor (AFF)Desk outletSpecial Use Areas1.5 ft [450 mm] AFFAs required by designPatient Bed Prefabricated Wall Units (PBPU): Use the provided receptacle box, conduit andconnections. The PBPU UL listing shall not be violated. The Lessor is responsible to restoreeach unit’s violated UL to the OEM standard at the Lessor’s expense.Special Systems: Provide each outlet minimum 18 in [450 mm] AFF unless otherwisespecified by system design or indicated on the drawings.Outlets shall not be located within 48 in [1200 mm] <strong>of</strong> the "swing open" side <strong>of</strong> inward openingdoors or within 18 in [450 mm] <strong>of</strong> light switches, thermostats, or other electrical receptacles.Elevator voice cables providing voice service to the elevator car shall be extended to theelevator equipment room.E. DrawingsThe A/E shall clearly show the locations <strong>of</strong> telecommunications outlets, conduit runs, cabletrays or wireways, equipment cabinets and/or racks, telecommunications rooms/backboards,terminal, junction, and/or pull boxes on the drawings.The A/E shall clearly show the exterior and/or underground raceway system, includingdistances between buildings, manholes, and in-ground pullboxes.All raceways sizes shall be indicated on the drawings.Drawings must include a detailed riser diagram for all distribution systems, and the interfacesbetween systems.Part I: Basic Solicitation Requirements – Page 129 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]F. Wires and CablesThe design <strong>of</strong> the raceway system in existing buildings shall incorporate the existing facilityTIP raceway systems. All unused existing distribution wires, cables, and pathway equipmentnot incorporated in the new or replacement pathway system shall be removed.For new construction, the voice and data structured cabling system shall be Category 6 cableand Category 6 termination hardware. Additionally, the system should be installed by astructured cabling contractor certified by the manufacturer to install the system and capable <strong>of</strong><strong>of</strong>fering the manufacturer’s system warranty. Such warranty should be a minimum <strong>of</strong> 20years.Plenum/CMP-rated wire or cable shall be provided in all areas’ air-handling plenum locations.Non-plenum/CM wire or cable may be provided in all other areas.G. Special Systems Specific Requirements(1) GeneralProvide systems as determined by project requirements. Not all systems may be required,and not all required systems may be listed below.(2) Nurse CallProvide nurse call system(s) as required. System(s) shall be as manufactured by RaulandBorg, General Electric, Simplex, or approved equivalent, as updated to most currenttechnology or manufacturer.Provide emergency nurse call stations in nonpatient ward toilet areas only at the followinglocations:Dental Service (if not covered by a hands-free telephone intercom system)Drug Dependency Treatment ClinicGenitourinary ClinicNuclear MedicineOncology Clinic/Area (if not covered by a Nurse Call or Code One/Blue system)(3) Public Address (PA)Provide public address and mass notification (PA) system(s) as required. System(s) shall beas manufactured by Bogen, JBL, Dukane, or approved equivalent, as updated to most currenttechnology or manufacturer.(4) Intercommunication SystemProvide intercommunications system(s) as required. System(s) shall be as manufactured byBogen, Aiphone, Leviton, or approved equivalent, as updated to most current technology ormanufacturer.Provide appropriate intercommunication systems at designated facility ingress and egresspoints connected to the Security Service Control Room.(5) Radio Entertainment Distribution (RED)Provide radio entertainment distribution (RED) systems as required. System(s) shall be asmanufactured by Bogen, JBL, Dukane, or approved equivalent, as updated to most currenttechnology or manufacturer.Part I: Basic Solicitation Requirements – Page 130 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]All loudspeakers shall be <strong>of</strong> the recessed or ceiling type in lieu <strong>of</strong> surface-mounted type,wherever possible.Loudspeakers in each day room, TV lounge, waiting room, and other designated areas thatalso contain PA speakers may be combined within the same speaker back box and grille, anduse the same speaker cone, as long as each speaker function contains a separate matchingtransformer and voice coil for each service (i.e., one transformer and associated voice coil forRED and one transformer and associated voice coil for PA). This consolidation practice is anacceptable alternate to two individual speakers, back boxes, grilles, and mounts in theselocations. Also, provide volume and selector controls in each <strong>of</strong> the aforementioned RED onlyareas at their Reception Room desk.(6) Master Antenna Television (MATV)Provide Master Antenna Television (MATV) systems as required. System(s) shall be asmanufactured by Blonder Tongue, Scientific Atlanta, Olson Technologies, or approvedequivalent, as updated to most current technology or manufacturer.Master Antenna system antennas shall be mounted on hinged poles (or equivalent) wheresubjected to salt-spray atmosphere.(7) Security Surveillance Television (SSTV)Provide SSTV systems as required. System(s) shall be as manufactured by Panasonic, VideoTek, Pelco, or approved equivalent, as updated to most current technology or manufacturer.(8) Security <strong>Management</strong> and Control, and Centralized Police Security <strong>Management</strong>Systems (aka Security <strong>Management</strong> Telecommunications System SMTS)Provide SMTS systems as required. System(s) shall be as manufactured by Lockheed, Viper,Access Gold, Casi-Rusco, or approved equivalent, as updated to most current technology ormanufacturer. LAN/WAN based systems must be on a separate and standalone system andNOT connected to the Facility’s LAN/WAN.Electronic Access and Door Control – Dyna Lock, Locknetics, Sentrol, or approvedequivalent, as updated to most current technology or manufacturer.Motion Intrusion Detection – Security Metrics, Ademco, Honeywell, or approvedequivalent, as updated to most current technology or manufacturer.Patient (also Staff) Annunciator/Locator System – Viking, Radiance, Secur Trak,Patient Central, or approved equivalent, as updated to most current technology ormanufacturer.Duress Alarm and Emergency Notification System – Code Blue Pole Systems orapproved equivalent, as updated to most current technology or manufacturer. Underno circumstance shall the telephone system be used to provide duress alarmfunctions.(9) Radio Paging SystemProvide radio paging system (identified as Public Safety Operation and upgraded to LifeSafety when interfaced to Code One (Blue)) as required. System(s) shall be as manufacturedby Motorola, Johnson, Kenwood, or approved equivalent, as updated to most currenttechnology or manufacturer.Part I: Basic Solicitation Requirements – Page 131 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY](10) Two-Way Radio SystemProvide two-way radio systems as required. System(s) shall be as manufactured by Motorola,Johnson, Vertex Standard, or approved equivalent, as updated to most current technology ormanufacturer.(11) Video Teleconferencing System (VTS)Provide VTS systems as required. System(s) shall be as manufactured by Polycom,Tandberg, HP, or approved equivalent, as updated to most current technology ormanufacturer.(12) Satellite SystemProvide VTS systems as required. System(s) shall be as manufactured by Scientific Atlanta,Blonder Tongue, Pico Macom, or approved equivalent, as updated to most current technologyor manufacturer.6.8.2 TELECOMMUNICATIONS/SPECIAL SYSTEMS ROOMS AND SPACE REQUIREMENTSA. ScopeThis chapter covers the requirements for telecommunications, data, and special systemsrooms and spaces.B. Room Types and Definitions(1) GeneralProvide rooms as determined by project requirements. Not all room types may be required,and not all required room types may be listed below.(2) //Telephone Console Room (TCR) (Optional)The Telephone Console Room is where telephone operators are located. Operators provideservice to the entire building. The Telephone Console Room is in many cases, but not all,continuously staffed. At many locations the operators also have the responsibility <strong>of</strong>monitoring critical alarms for equipment throughout the facility.//(3) //Head End Equipment (HE) Room (Optional)The Head End (HE) Equipment Room will be located in the general mechanical penthouse orother area dictated by system design. The room will accommodate all provided and plannedSpecial Systems, Head-end Cabinets (i.e., MATV, SSTV, SSTV, RED, Satellite TV, PA, Two-Way Radio, Radio Paging, and M/W Radio, etc.). The room will be sized for a minimum <strong>of</strong> (5)each separate systems.//(4) Telecommunications Room (TR)The Telecommunications Room is a room designed to centrally deliver data, telephone, andspecial systems services to users and equipment on that floor. There may be multiple roomson a floor.The design "Telecommunications Room" replaces the term "Signal Closet," which is no longerused. The new designation indicates the current construction practice <strong>of</strong> combiningtelephone, data, special systems, and fire alarm functions into one terminus, control, anddistribution point. If security requirements require separation <strong>of</strong> systems, this will beaccomplished by a chain link or other barrier that will provide physical security while allowingcommon lighting, heating and cooling, and power protection systems.Part I: Basic Solicitation Requirements – Page 132 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY](5) //Remote or Secondary Telecommunications Room (TR) (Optional)These rooms are typically provided for Special Systems that are allowed in patient or otherdesignated areas that exceed the 300 foot [90 meters] maximum wire distance toTelecommunications Rooms, and the installation area is small enough so as to not warrant thelarger and more costly stacked Telecommunications Rooms.//(6) //Entrance Room (ER OR DMARC) (Optional)The Entrance Room (ER) is a room or rooms designed to be the initial termination point forservices being brought to the building by outside providers, such as telephone companies,data providers, CATV providers, etc.//(7) //Telephone Equipment Room (TER)The Telephone Equipment Room will be designed to house equipment to provide telephone,voice, and video teleconferencing services to the facility. It shall be interconnected with theDEMARC, MCR, and TRs via the facility’s TIP system.//(8) //Main Computer Room (MCR) (Optional)The Main Computer Room (MCR) will be designed to house equipment to provide dataservices to the entire building or facility. In addition to the Main Computer Room, there maybe a standby computer room that will provide backup services in the event <strong>of</strong> a catastrophicfailure at the Main Computer Room.//(9) Police, Emergency, and Designated Control RoomsPolice Control Room (PCR), Engineering Control Room (ECR), and other designated controlrooms are other rooms throughout the facility that house specialized functions.C. General Environmental, Power and Space Requirements(1) GeneralThe following is a list <strong>of</strong> minimal environmental, power, and space requirements that apply toall telephone, data, and special system rooms and spaces (hereinafter ‘rooms’ in this article)that contain electronic equipment. The list is not all inclusive and additional information orrequirements may be found in this chapter.(2) Location, Protection, and AccessRooms shall be rectangular in shape and free <strong>of</strong> obstructions, such as columns and braces, ifpossible. If columns or braces are present, they shall not impede the installation or operation<strong>of</strong> individual system equipment and access to each equipment cabinet’s front, side, or rear.The floor area occupied by the column shall not be counted as a part <strong>of</strong> the room’s minimumuseable square foot requirements.Rooms shall be located above the Base Flood Elevation. Rooms shall not be located beneathtoilets, showers, laboratories, kitchens, sinks, open courtyards, planters, ro<strong>of</strong> drain leaders, orother areas where water service is provided. Active telephone, data, and special systemsequipment is not allowed to be installed in elevator penthouses or mechanical rooms;dedicated rooms are required.Rooms shall be designed to allow maintenance equipment access, and to facilitate equipmentreplacement without significant demolition and reconstruction.Rooms shall not be located in patient care areas.Part I: Basic Solicitation Requirements – Page 133 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Any pipe or duct system foreign to the telecommunications installation shall not enter or passthrough a room. The A/E shall ensure that foreign piping such as water pipes, steam pipes,medical gas pipes, soil pipes, sanitary drains, storm drains, A/C ducts, and other unrelatedsystems utilized for or containing liquids, or gases are not installed or pass through rooms.Sprinkler piping serving only telecommunications spaces shall not be considered foreign to thetelecommunications installation, and shall not pass through the space to serve other areas.Rooms shall be located away from or protected from sources <strong>of</strong> EMI at a distance which willreduce the interference to less than 3.0V/M through the frequency spectrum. Pay specialattention to EMI from electrical power supplies, transformers, motors, generators, x-rayequipment, radio transmitters, and induction heating devices.Rooms shall be located to minimize effects <strong>of</strong> lightning strikes and sunlight radiant heating.Rooms shall not have windows.Rooms that are considered computer rooms should not be located on exterior walls.Rooms shall have a controlled access door with card reader to control access to authorizedpersonnel.(3) Room EnvelopeFinish flooring shall be anti-static plastic laminate or vinyl tile. The acceptable resistancerange is from 0.5 megohm minimum to 20,000 megohm maximum.Floors, walls and ceilings shall be sealed to prevent dust, and all walls shall be painted a lightcolor.Backboards shall be ¾" fire-retardant plywood.(4) Heating, Ventilation, and Air ConditioningDesign conditions shall be 75 ˚F [24 ˚C] dry bulb temperature (cooling), 65 ˚F [18 ˚C] dry bulbtemperature (heating), with individual room temperature control.(5) PowerPower for all rooms and equipment shall be connected to the appropriate branch <strong>of</strong> theEssential Electrical System. Equipment shall be backed by an uninterruptible power supply(UPS), except HVAC equipment. Provide 120V 20A and 30A capacity, and 220/208V 20/30Acapability as required. Match receptacles types with equipment provided and installed by VA<strong>Office</strong> <strong>of</strong> Information and Technology (OI&T).(6) GroundingTelecommunications systems grounding and bonding will consist, at a minimum, <strong>of</strong> anequipotential grounding system (Telecommunications Bonding Backbone (TBB)) thatoriginates from the Telecommunications Main Ground Bar (TMGB). The TMGB (typicallylocated in the Telephone Equipment Room) is then connected to other telecommunicationsspaces (independently from other building grounding systems such as electrical or lightningprotection) via the TBB. The TMGB is connected to the building electrical service ground pointvia a mechanically and electrically protected minimum #1/0 copper equipotential groundingconductor, and to building steel. The TBB helps ensure that all equipment in thetelecommunications spaces is referenced at the same equipotential earth ground level, andreduces high frequency electrical noise resulting from high speed digital switching, RFI, andEMI. Cabinet, rack and fixed structures bonding conductor(s) shall be minimum #6 AWG-Part I: Basic Solicitation Requirements – Page 134 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]insulated stranded copper wire (or equal copper braid). All frames and cabinets shall begrounded in accordance with ANSI/TIA/EIA-607.The telecommunications grounding system will comply with ANSI/TIA/EIA-607 requirementsand follow BICSI – Telecommunications Distribution Methods Manual (Latest Edition)guidelines.(7) SecurityComply with Physical Security Criteria in Paragraph 4.2.4 PHYSICAL SECURITY ANDNATURAL DISASTERS RESISTIVE DESIGN and as follows. Provide electronic securitysystem that is connected to and fully functional with the PCR SMTS and a cipher lock withnumeric keypad, associated electronic card access device, and electric strike. Each roomsecurity system shall be powered from either the building or a local UPS system.Each programmable door control shall be fully functional with the SMTS in a stand-alonestatus if its connection to the controller is cut. Once the connection is restored, the local doorcontrol system shall update the SMTS on all operations that occurred after the connection wasinterrupted, and the SMTS shall update the local door control units to current operationalfunction.(8) Wire <strong>Management</strong>Refer to Paragraph 6.8.1 for requirements.D. Telephone Console Room (Optional)(1) ConfigurationSpace shall be per the following table:Telephone Console Room Size RequirementsNUMBER OF CONSOLES SPACE REQUIRED SQ M (SQ FT)1 100 [9]2 150 [14]3 200 [19]Provide a restroom and break room, separate from the operations area.(2) Heating, Ventilation, and Air ConditioningRefer to Paragraph 6.8.2C General Environmental, Power and Space Requirements-Heating,Ventilation, and Air Conditioning.(3) PowerRefer to Paragraph 6.8.2C General Environmental, Power and Space Requirements.Provide sufficient 120V receptacles at each operator position.(4) Alarm PanelsProvide adequate space, heating and cooling, power, lighting, and telecommunicationsraceways for alarm panels as required for each project. At a minimum, provide for nurse callCode One (Blue), public address, emergency notification, duress alarm, fire alarm, andemergency and standby generator alarm annunciator panels.Part I: Basic Solicitation Requirements – Page 135 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]E. Head End Equipment (HE) Room (Optional)(1) GeneralThis section covers the requirements for the Head End Equipment (HE) Room. The HE Roommay include, but is not limited to, head end cabinets for MATV, SSTV, SSTV, RED, satelliteTV, PA, two-way radio, and radio paging systems.(2) LocationA dedicated room is required. This room may be located in the mechanical penthouse (asclose as possible to a ro<strong>of</strong> entrance) or attic, or an area as dictated by system design. It shallnot be located in the elevator equipment room, or in the basement, or below the Base FloodElevation.The HE Room shall not be located further than 300 feet [91.44 meters] from the nearestvertically stacked Telecommunications Room.If located in the mechanical penthouse or attic, the room may be separated from the rest <strong>of</strong> thearea by floor-to-ceiling metal chain-link security fence with a minimum 40" x 84" inch lockinggate with two sets <strong>of</strong> keys. If located in the HE Room, telephone or data equipment shall notuse fencing <strong>of</strong> any type except to partition area within the secure HE Room.(3) ConfigurationThe HE Room shall be a minimum <strong>of</strong> 10 foot x 12 foot [3.0 m x 3.7 m], or as large as the sum<strong>of</strong> the provided and future systems require, including space for UPS equipment. The HERoom shall be sized for the head end equipment <strong>of</strong> a minimum <strong>of</strong> five (5) each separatesystems, four (4) each future systems, one (1) each overhead, and wall wire managementsystem, four (4) each 4" ID weatherpro<strong>of</strong> wall/ceiling cable feedthroughs, and two (2) each 4"ID conduits to the nearest vertically stacked telecommunications room. The space for futuresystems shall be clearly indicated on the contract documents. Space shall be per thefollowing table:Head End Equipment Room Size RequirementsNUMBER OF EQUIPMENTCABINET/RACKSROOM SIZESQ M (SQ FT)4 minimum 224 [22]Add 2 UPS 224 [22]Add 1 for System Grounding256 [24]Block/Main TIP DistributionPanel (MTDP)5 minimum 256 [24]Add 2 for UPS 256 [24]Add 1 for System Grounding289 [27]Block/MTDPCabinets are installed joined or side by side, in which case where the 3 foot [900 mm] ruleapplies around the entire assembly. Minimum ceiling height shall be 8 feet [2.4 m] abovefinished floor.The HE Room may be sized to use an Environmental Equipment Protection Cabinet in lieu <strong>of</strong>an air-handled space, if previously approved by VA. Add three (3) each sf with 3 ft clear floorarea circumference per environmental cabinet.Part I: Basic Solicitation Requirements – Page 136 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY](4) Tip Wire/Cable Interface AreaProvide a wall area, minimum size <strong>of</strong> 8 feet x 8 feet [2.4 m x 2.4m] (plywood covered, toprovide a common termination point for all the cabling entering and leaving the HE Room).(5) Heating, Ventilation, and Air ConditioningRefer to Paragraph 6.8.2C General Environmental, Power and Space Requirements.A fully climate-controlled, standalone equipment cabinet is acceptable for each special systemin lieu <strong>of</strong> fully acclimatizing the HE Room.(6) PowerRefer to Paragraph 6.8.2C General Environmental, Power and Space Requirements.(7) GroundingProvide a copper bus plate minimum 6 in [150 mm] w x 18in [470 mm] L x 0.5 in [13 mm], witha connection point located on the inside wall within the immediate area <strong>of</strong> the antenna coaxialcable(s) entrance conduit sleeves. Connect this plate to the lightning protection system with aminimum #1/0 (AWG) stranded copper wire, or increased sized connection device (i.e., strap,buss, etc.), as approved by the RE, to maintain the integrity <strong>of</strong> the lightning protection systemso each <strong>of</strong> the system antenna cables’ coaxial cable lightning protector can be installed andconnected to the plate.Refer to Paragraph 6.8.2C General Environmental, Power and Space Requirements foradditional requirements.(8) Wire <strong>Management</strong>Refer to Paragraph 6.8.1 for additional requirements.The HE Room shall be provided with waterpro<strong>of</strong> wall entrance sleeves to allow connecting <strong>of</strong>each outside antenna coaxial cable to the HE Room equipment. Add extra like sleeves foradditional outside-mounted antennas as required by system design. One <strong>of</strong> these sleevesshall contain only the lightning protection connection.The HE Room shall be provided with a minimum separate 6 in [150 mm] x 6 in [150 mm] cableduct/ladder/wireway from the designated TIP interface point to the dedicated waterpro<strong>of</strong>locking 24" x 24" x 12" [600 mm x 600 mm x 300 mm] TIP connection enclosure. A minimum12" cable ladder may be used for this purpose. A minimum <strong>of</strong> five (5) each 3" conduits may beprovided in lieu the cable duct/ladder/wireway; additional cable duct/ladder/wireway shall beprovided based on overall system design.The mixing <strong>of</strong> coaxial cables and STP/UTP/fiber optic/AC and DC power wiring within thecable duct/ladder/wireway and/or conduits is not allowed.Each wire/cable connection point shall be provided with a connection MDF capability androutes to connect the room’s internal wire management system to the facility’s TIP system.F. Telecommunications Room (TR)Rooms shall be provided in the quantities and locations that will limit telephone/data/specialsystems TIP cable/wire runs from the Telecommunications Room to the outlets to a maximum<strong>of</strong> 300 feet [90 m]. Splicing <strong>of</strong> cables is not allowed. Terminal cabinets shall not be used inlieu <strong>of</strong> Telecommunications Rooms.Part I: Basic Solicitation Requirements – Page 137 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY](1) ConfigurationMinimum room size shall be 10 feet [3 m] deep x 10 feet [3.6 m] wide. Minimum door sizeshall be 50 in [1,000 mm] wide x 84 in [2,100 mm] high. For every additional 10,000 sq ft [930sq m] <strong>of</strong> floor space served, there shall be 10 linear feet [3 linear m] <strong>of</strong> wall space required.The TR Room will have a minimum <strong>of</strong> 4-19 inch racks with vertical wire management. The TRRoom shall be sized for the building head end equipment requirements.Rooms shall be vertically stacked.The back wall <strong>of</strong> all rooms shall be lined with backboards, 8 feet [2.44 m] high, with the bottom1 foot [0.30 m] above the finished floor.Room height shall be a minimum <strong>of</strong> 9 feet [2.74 m] above finished floor. Rooms shall not havea suspended ceiling.Entrance must have a minimum unobstructed area <strong>of</strong> 48 in [1200 mm] directly in front <strong>of</strong> theroom door.(2) Heating, Ventilation, and Air ConditioningRefer to Paragraph 6.8.2C General Environmental, Power and Space Requirements.Cooling shall be provided according to the actual expected equipment installation and use.(3) PowerRefer to Paragraph 6.8.2C General Environmental, Power and Space Requirements.Provide a separate 120V, dedicated 20A circuit with two (2) quadraplex receptacles centeredin each side backboard, two (2) quadraplex receptacles centered in each front backboardeither side <strong>of</strong> the room door, and three (3) quadraplex receptacles centered in the rearbackboard. All receptacles shall be 18 in [457.2 mm] above finished floor. Allow 3 quadraplexreceptacles on each 20 A circuit.(4) GroundingRefer to Paragraph 6.8.2C General Environmental, Power and Space Requirements.(5) Wire <strong>Management</strong>Refer to Paragraph 6.8.1.Each room shall be provided with lateral and vertical risers from the TER and MCR to eachroom to support a separate TIP distribution system for telephone, data and special systems.G. Remote or Secondary Telecommunications Rooms (Optional)(1) LocationProvide these rooms as required by each system design.These rooms are typically provided for Special Systems that are allowed in patient or otherdesignated areas that exceed the 300 foot [90 m] maximum wire distance toTelecommunications Rooms, and have a small enough installation area so as to not warrantthe larger and more costly stacked Telecommunications Rooms.Part I: Basic Solicitation Requirements – Page 138 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY](2) ConfigurationEach room shall be a minimum <strong>of</strong> 6 feet x 8 feet x 8 feet [1.58 m x 2.4 m x 2.4 m] or accordingto BICSI Wiring Standards for the areas, whichever is greater. The minimum door size shallbe 36 in [900 mm] wide by 84 in [2,100 mm] high.Each wall shall be provided floor to ceiling with backboards and two (2) 19 inch racks withvertical wire management.(3) Heating, Ventilation, and Air ConditioningRefer to Paragraph 6.8.2F Telecommunications Room (TR).(4) PowerRefer to Paragraph 6.8.2F Telecommunications Room (TR).(5) GroundingRefer to Paragraph 6.8.2F Telecommunications Room (TR).(6) Wire <strong>Management</strong>Refer to Paragraph 6.8.2F Telecommunications Room (TR).H. Terminal Cabinets (Optional)Terminal cabinets may be used where the number <strong>of</strong> outlets served is minimal, the distance <strong>of</strong>the run is in excess <strong>of</strong> 300 feet [90 m] from the otherwise nearest vertically stackedTelecommunications Room, and/or the cost <strong>of</strong> providing a Telecommunication Room isprohibitive. The use <strong>of</strong> terminal cabinets as a substitute for Telecommunications Rooms willnot be approved.Where required, each cabinet shall be not less than 16-gauge steel with doors and concealedhinges attached by welding.Doors must be secured by a lock with a minimum <strong>of</strong> two keys.Shall be thoroughly cleaned and painted at the factory with primer and the OEM's standardfinish.Each cabinet shall have a backboard covering the entire interior surface <strong>of</strong> the back <strong>of</strong> eachcabinet if equipment-mounting rails are not required.Cabinets shall have a minimum inside depth <strong>of</strong> 16 in [400 mm] from the inside <strong>of</strong> the door tothe face <strong>of</strong> the backboard.For Special Systems, provide equipment-mounting rails, guides, and shelves in lieu <strong>of</strong> thebackboard. However, a backboard is acceptable if the cabinet is used solely for theinterconnection and distribution <strong>of</strong> systems wires or cables where active or electronicequipment is not provided.I. Entrance Room (ER or DMARC) (Optional)(1) LocationRefer to Paragraph 6.8.2C General Environmental, Power and Space Requirements.Part I: Basic Solicitation Requirements – Page 139 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY](2) ConfigurationThe Entrance Room shall be a minimum <strong>of</strong> 12 feet x 8 feet[3.7 m x 2.4 m], and shall beequipped with backboards as required by system design.(3) Other RequirementsAll other requirements <strong>of</strong> Paragraph 6.8.2C General Environmental, Power and SpaceRequirements apply to the Entrance Room.J. Telephone Equipment Room (TER)(1) LocationThe TER shall be located within a cable distance <strong>of</strong> 100 feet [30 m] <strong>of</strong> the Telephone ConsoleRoom (if provided). It should be located close to the DEMARC and MCR rooms (if provided).A floor drain, evacuating and/or sump water pump, etc., shall be provided within the room ifrisk <strong>of</strong> water ingress exists. A high water level alarm annunciating system shall be provided inaddition to intrusion alarm(s) that connects to the facility’s ECR, PCR, SMS Console, and oneother continuously-manned location.(2) ConfigurationSpace shall be per the following table:Minimum Telephone Equipment Room SizeNUMBER OF LINES ROOM SIZE SQ FT [SQ M](GEN SIZE)200 to 300 168 [11] (12’ X 14’)301 to 600 250 [23.5] (12’ X 20’)601 to 900 500 [47] (20’ X 25’)901 to 1,600 700 [65] (20’ X 35’)1,601 to 2,000 900 [84] (20’ X 45’)2,001 to 2,400 1,100 [102] (20’ X 55’)2,401 to 2,800 1,300 [121] (25’ X 44’)2,801 to 3,200 1,500 [140] (34’ X 45’)3,201 to 4,000 1,700 [158] (34’ X 50’)A minimum <strong>of</strong> 3 feet [910 mm] shall be provided around each cabinet unless the cabinets areinstalled joined or side by side where the 3-foot [910-mm] rule applies around the entireassembly. Minimum suspended ceiling height shall be 8 feet [2.4 m] above finish floor. TheTER shall be a minimum <strong>of</strong> 12 feet x 14 feet [3.7 m x 4.3 m].Provide a metal insulated door equipped with a deadbolt key lock and/or electronic lock. Also,each door shall be provided with an intrusion alarm to be annunciated locally, at the Facility’sEngineering Control Room, Security Police Control Console, and one other continuouslymannedlocation (i.e., Telephone Operator or MAS Emergency Room Desk).Sufficient backboards shall be provided to limit interconnection wire and cable length frombackboard to the room wire management system and planned cabinets. Backboards shall belocated so as to allow unobstructed access to entrance and exit cable ducts, internal roomwire management system, cabinets and doors.Part I: Basic Solicitation Requirements – Page 140 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Room height shall be a minimum <strong>of</strong> 9 feet [2.74 m] above finished floor. Rooms shall not havea suspended ceiling.Sufficient space should be provided for UPS equipment.(3) Room EnvelopeRoom shall be enclosed with fire-rated construction in accordance with NFPA 75.(4) TIP Wire/Cable Interface AreaWithin the TER there will be an area designated that houses and locates all TIP conduit andcable pathway terminations coming into the room from TRs, HE room, MCR, and either thesingle or duplicated Entrance Rooms (DEMARC). This area will house the distribution cablemanagement system.This area shall be a minimum <strong>of</strong> 12 feet x 8 feet x 8 feet [3.7 m x 2.4 m x 2.4 m] in addition tothe minimum area required by the Telephone Equipment Room.(5) Heating, Ventilation, and Air ConditioningDesign Conditions: 64 ˚F [18 ˚C] to 75 ˚F [24 ˚C] dry bulb temperature, 30 to 55% relativehumidity.HVAC load calculations shall include the rectifiers and associated batteries. Coolingrequirements shall be based on system design with 30% reserve capacity. Cooling equipmentshall be dedicated to the room, and an N+1 configuration shall be provided for reliability.(6) PowerRefer to Paragraph 6.8.2C General Environmental, Power and Space Requirements.UPS system must provide power for a period <strong>of</strong> 4 hours. Power shall be distributed by PowerDistribution Units (PDUs).UPS equipment shall be sized based on the equipment requirements, plus future anticipatedgrowth. The initial design load shall not be less than 30% and not more than 70% <strong>of</strong> the UPScapacity.The UPS shall be monitored by the PCR SMS for power, alarms, and alarm history. The UPSshall have dry contacts or external alarm and control from the PCR SMS and one "C" contactfor local computer signaling. The UPS shall be provided with computer system shutdowns<strong>of</strong>tware and hardware connectivity as required.The sharing <strong>of</strong> the TER’s UPS is NOT allowed.The room shall be equipped with dedicated electrical panel(s) capable <strong>of</strong> providing 208/120V,3-phase, 4-wire power, with capacity designed for the equipment load plus future capacity.Each panel shall contain 20% spare electrical capacity and spare circuit breaker space.Provide a minimum <strong>of</strong> one quadraplex receptacle (two duplex) for each 8 linear feet [2.4 linearmeters] <strong>of</strong> wall space.Emergency Power Off (EPO) push buttons shall be installed according to NFPA 75.Part I: Basic Solicitation Requirements – Page 141 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY](7) LightingIn addition to room lighting, provide battery-powered lighting in accordance with NFPA 75 and101.(8) GroundingRefer to Paragraph 6.8.2C General Environmental, Power and Space Requirements.The Telephone Equipment Room shall be provided with a building earth ground connection bya clearly marked copper equipotential bus bar (Telecommunications Main Ground Bar(TMGB)).The TMGB shall be directly connected to the facility’s electrical ground via a mechanically andelectrically protected minimum #1/0 AWG stranded copper equipotential grounding conductor.An AC electrical equipment grounding conductor is not acceptable for this function and will notbe approved.(9) SecurityRefer to Paragraph 6.8.2C General Environmental, Power and Space Requirements.Each door shall have a color security surveillance camera that connects to a color monitor inthe IT Chief’s <strong>Office</strong> and is routed to the PCR.A MID system shall be installed within the TER. The system shall be controlled and monitoredby the PCR SMS.An emergency voice-operated sound system shall be installed within the TER, terminated inthe PCR SMS and the IT Chief’s <strong>Office</strong>.A duress alarm button shall be placed every 10 linear feet [3 linear meters] within the TER,annunciating to the PCR SMS and ECR, in addition to the Telephone Console Room and oneadditional continuously-manned location.(10) Wire <strong>Management</strong>Refer to Paragraph 6.8.1 for requirements.K. Main Computer Room (MCR) (Optional)(1) ReliabilityThe Uptime Institute has developed a system for classifying the expected reliability <strong>of</strong> datacenters and computer rooms based on how the rooms were constructed, types <strong>of</strong> equipmentused, and how services were delivered. Four tier levels were designated, and high levelcharacteristics along with expected reliability for each tier are listed below:Tier ITier IITier IIITier IVTier I is composed <strong>of</strong> a single path for power and cooling distribution,without redundant components, providing 99.671% availability.Tier II is composed <strong>of</strong> a single path for power and cooling distribution,with redundant components, providing 99.741% availability.Tier III is composed <strong>of</strong> multiple active power and cooling distributionpaths, but only one path active, has redundant components, and isconcurrently maintainable, providing 99.982% availability.Tier IV is composed <strong>of</strong> multiple active power and cooling distributionpaths, has redundant components, and is fault-tolerant, providing99.995% availability.Part I: Basic Solicitation Requirements – Page 142 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Designers should be familiar with the concepts involved and incorporate as many <strong>of</strong> thespecific Tier III requirements into their design as practical.(2) LocationRefer to Paragraph 6.8.2C General Environmental, Power and Space Requirements.Provide moisture sensors and water alarm annunciating system to signal an alarm conditionwithin the MCR and the control room. Annunciate at the Police Control Room (PCR), Security<strong>Management</strong> Telecommunications System (SMTS) Console, and one other continuouslymannedlocation (i.e., Telephone Operator or MAS Emergency Room Desk). Provide sumpand pump for under floor area <strong>of</strong> raised floor systems where risk <strong>of</strong> water ingress exists.(3) ConfigurationThe MCR useable floor area square footage (sf) requirements shall be minimum 1,200 sq feet(10 feet x 12 feet) [3 m x 3.7 m] and shall be increased on a case-by-case basis in minimum <strong>of</strong>150 sq feet (10 feet x 15 feet) [3 m x 4.57 m] increments for:Each additional 8,500 sq feet [2591 sq meters] <strong>of</strong> facility floor space above the initialfacility designed floor space.Unique equipment footprint(s), configuration <strong>of</strong> new systems, ramps, doors, and aisleways, maintenance access to equipment, ceiling and floor furnishings.UPS equipment and main and emergency batteries, power distribution units (PDUs),etc.Main and intermediate telecommunication interface/distribution room(s) and corridors.Provide <strong>of</strong>fice(s) required for MCR function and operation (i.e., Chief’s, data storage,maintenance/service, etc.).Provide one (1) each additional space to encompass projected expansion, to be includedseparately after each <strong>of</strong> the aforementioned added space requirements have beenincorporated into the MCR design.A minimum <strong>of</strong> 3 feet [0.91 m] shall be provided in front and back <strong>of</strong> each rack or cabinet.Minimum suspended ceiling height shall be 9 feet [2.7 m] above finish floor. The MCR shallbe a minimum <strong>of</strong> 10 feet x 12 feet [3 m x 3.7 m] or as large as the sum <strong>of</strong> the plannedsystems, two spare systems, and access requirements.Sufficient backboards shall be provided to limit interconnection wire and cable length frombackboard to the room wire management system and planned cabinets. Backboards shall belocated so as to allow unobstructed access to entrance and exit cable ducts, internal roomwire management system, cabinets, and doors.(4) EnvelopeRoom shall be enclosed with fire-rated construction in accordance with NFPA 75.(5) Tip Wire/Cable Interface AreaWithin the Main Computer Room, there will be an area designated that houses and locates allTIP conduit and cable pathway terminations coming into the room from TelecommunicationRooms, HE room, MCR, and either the single or duplicated Entrance Rooms. This area willhouse the distribution cable management system.Part I: Basic Solicitation Requirements – Page 143 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY](6) WallsWalls shall be reinforced on jamb side <strong>of</strong> Ballistic Resistant doors to BR Level 3, UL 752 towithin 48 in [1200 mm] <strong>of</strong> each jamb from structural floor to MCR ceiling height.(7) FloorProvide access floor <strong>of</strong> "bolted stringer design" in the MCR and each subordinate computerroom to accommodate power, data and telecommunications cabling, and other authorizedutilities.The access floor shall meet the requirements <strong>of</strong> Paragraph 7.8.8 //COMPUTER ROOMFLOORING.The access floor shall be used as a cooling air plenum for air conditioning units. Thesupporting structure and "stringers" shall be connected to signal ground system with aminimum #2 AWG stranded copper wire.Water and smoke detection devices are required beneath the access floor.Doors: The MCR shall have a minimum <strong>of</strong> two outward-swinging doors, 48 in [1200 mm] wide,on each end <strong>of</strong> the MCR. One door shall exit directly into a corridor.Doors shall be Ballistic Resistant BR, Level 3 in accordance with U.L. Standard 752.Panic exit hardware, closers, and facility SMTS functional control and operation shall beprovided on each door.Ceiling: Finished ceiling height shall be minimum 9 feet [2.7 m] clear above the access floor.The suspended acoustical shall be clean-room mylar or ceramic type with a minimum noisereduction coefficient (NRC) <strong>of</strong> .55. Ceilings shall have a flame spread <strong>of</strong> less than 25 and asmoke development ratio <strong>of</strong> 50 or less, according to American Society <strong>of</strong> Testing andMaterials (ASTM) Standard E-84.(8) Heating, Ventilation, and Air ConditioningDesign Conditions: 64 ˚F [18 ˚C] to 75 ˚F [24 ˚C] dry bulb temperature, 30 to 55% relativehumidity.Two identical and independent dedicated MCR air conditioning units are required. Coolingrequirements shall be based on system design with 30% reserve and in an N+1 configurationfor reliability. The units shall be positioned at opposite ends <strong>of</strong> the MCR, diagonally oppositeeach other. The units shall have local and PCR SMTS monitoring and alarm annunciators.Air filters shall be MCR grade high efficiency. Both units shall operate at all times and sharethe load, unless one fails or is undergoing maintenance. The units shall be independentlysupported on OEM supplied stands <strong>of</strong> the same height as the raised floor.The air conditioning units shall include refrigerant systems and glycol or DX cooling. Coolingcapacity <strong>of</strong> each unit shall be able to remove all the sensible heat from the MCR. This heat isattributable only to the UPS loads and the heat loss due to the units and the UPS itself(typically 7 – 10%). Heat load from the air conditioning units shall be taken into account.Each unit capacity shall be allowed to remove 110% <strong>of</strong> the UPS load with both units operating.Part I: Basic Solicitation Requirements – Page 144 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]The raised access floor shall act as the air supply plenum, and shall provide cooling to theequipment and room using cutouts and vent tiles. A minimum <strong>of</strong> one tile vent per 100 sq feet[30.48 sq meters] is required.A fresh air supply from the building’s HVAC system shall be provided to the MCR with a firedamper where the ductwork passes through the MCR firewalls. This shall keep the room at apositive pressure and provide cooling for lighting and personnel load <strong>of</strong> the room. Theminimum building air supply shall be 200 to 300 cubic feet per minute (CFM) [94 to 142 L/s].(9) PowerRefer to Paragraph 6.8.2C General Environmental, Power and Space Requirements.The room shall be equipped with dedicated electrical panel(s) capable <strong>of</strong> providing 208/120V,3-phase, 4-wire and designed for the equipment load. Each panel shall contain 20% spareelectrical capacity and spare circuit breaker space.Provide a minimum <strong>of</strong> one quadraplex receptacle (two duplex) for each 8 linear foot [2.4 linearmeter] <strong>of</strong> wall space.Provide physical space and electrical capacity for an uninterruptible power supply (UPS)system that will provide power for four hours to Main Computer Room equipment. The UPSwill be provided by the VA.UPS equipment physical space and electrical capacity shall be sized based on the equipmentrequirements, plus future anticipated growth. The initial design load shall not be less than30% and not more than 70% <strong>of</strong> the UPS capacity.Each workstation within the Main Computer Room shall be provided with one UPS-backedduplex receptacle and two duplex normal power receptacles for desk lamps, fans, pencilsharpeners, etc.Emergency Power Off (EPO) push buttons shall be installed according to NFPA 75 and 101.(10) LightingProvide battery-powered lighting in accordance with NFPA 75 and 101.(11) GroundingRefer to Paragraph 6.8.2C General Environmental, Power and Space Requirements.(12) SecurityEach door shall have a color security surveillance camera that connects to a color monitor inthe PCR.A Motion Intrusion Detection (MID) system shall be installed within the TER. The system shallbe controlled by the PCR SMTS.A duress alarm button shall be placed every 10 linear feet [3 linear meters] within the TER,annunciating to the PCR, SMTS, ECR, and the Telephone Console Room, and one additionalcontinuously-manned location.(13) Wire <strong>Management</strong>Refer to Paragraph 6.8.1.Part I: Basic Solicitation Requirements – Page 145 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Provide sleeves and conduit for initial and anticipated TIP access to the MCR.L. Police, Engineering and Other Designated Control Room(s)These rooms shall comply with Paragraph 6.8.2B(2) //Telephone Console Room (TCR)(Optional).Provide these rooms with adequate designated TIP connectivity between the TER and MCR.6.9 //ELEVATORSThe Lessor shall provide two (2) elevators for VA use in all multi-story buildings or in space<strong>of</strong>fered above ground, to provide for full access. One elevator shall be a passenger elevatoras described below, the second shall be a service elevator as described below. Elevatorsshall conform to the requirements <strong>of</strong> the American Society <strong>of</strong> Mechanical Engineers A17.1,Safety Code for Elevators, Dumbwaiters, Escalators, and Moving Walks; NFPA 70 (NationalElectrical Code). Elevators shall meet accessibility requirements. Refer to Paragraph 4.6OSHA REQUIREMENTS.Elevators shall be inspected and maintained in accordance with American Society <strong>of</strong>Mechanical Engineers (A17.2), Inspector's Manual for Elevators.Passenger and service elevators platforms and entrance doors shall be <strong>of</strong> size andconfiguration specified to accommodate VA or ambulance gurneys.Passenger elevator shall be minimum 4,000 pound capacity with 8’-0" wide by 6’-2" deepplatform.Service elevator shall be minimum //4,000 pound capacity with 6’-0" wide by 8’-8" deepplatform// //5,000 pound capacity with 6’-8" wide by 8’-8" deep platform//.The entrance openings for passenger and service elevator doors shall be 48 inches wide by84 inches high. Doors shall be single-speed center opening, or two-speed side slide.Provide an autodial system with hands free operation which is activated by the emergencyalarm switch or call button in main and auxiliary control panels. The system shall be designedto communicate to a location in the building staffed during all working hours, such as thesecurity <strong>of</strong>fice or telephone operator. After working hours, the autodial system shall rollover toan emergency number.The floor covering in the car shall be a non-slip, firm surface which permits easy movement <strong>of</strong>wheelchairs. Carpet <strong>of</strong> any kind is not acceptable.Emergency Lowering: Emergency power operation <strong>of</strong> elevators is not required. Lessor shallprovide a backup power source to provide emergency lowering upon loss <strong>of</strong> normal power asfollows. Upon loss <strong>of</strong> normal power, each elevator shall return to the lowest landing byactivating the down valve. After the elevator has leveled at the lowest landing, provide powerto open the car doors automatically. After a predetermined time, the car doors shall close.Power shall stay applied to the door open button so the doors can be opened from inside theelevator only. The elevator shall remain shut down at the bottom landing until normal power isPart I: Basic Solicitation Requirements – Page 146 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]restored. A sign shall be installed on the controller indicating that power is applied to the downvalves and door operators during loss <strong>of</strong> normal power.//Part I: Basic Solicitation Requirements – Page 147 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]SECTION 7 INTERIOR CONSTRUCTION, FINISHES, AND INTERIOR DESIGN7.1 GENERAL7.1.1 SPACE PLANNING AND FUNCTIONAL LAYOUTThe conceptual floor plan (PART IX) provided in this solicitation shall be used as the basis forthe planning and functional layout <strong>of</strong> the facility. The final layout, design developmentdocuments, and construction documents shall be in accordance with Paragraph "Design and<strong>Construction</strong> Documents After Award" in this solicitation. The completed building shallaccommodate VA’s space program and interior functional requirements. Offerors are advisedthat the conceptual plans have been developed using VA Space Planning Criteria andinformation from VA Outpatient Clinic (SOC/CBOC) Design Guide which may be found athttp://www.cfm.va.gov/til/dGuide.asp#PC.Lessor shall provide accurate space layout drawings (floor plans) with <strong>of</strong>fer and during designand construction document phases. Plans shall include sufficient information for theGovernment to compute the net area <strong>of</strong> each function (room), and to compute Building GrossArea and Net Usable Area in order to determine compliance with solicitation requirements.7.1.2 ROOM NUMBERING//The Lessor shall use the room numbering system established by VA in the conceptual planson the design development and construction documents.////The Lessor shall work closely with VA to establish the room numbering system to be used forthe facility.//7.1.3 CIRCULATION SYSTEMSThe conceptual floor plan in this <strong>SFO</strong> defines the basic elements <strong>of</strong> the interior circulationsystems and their relation to the functional plan within VA occupied space. The Lessor isresponsible for the final design <strong>of</strong> horizontal and vertical circulation systems including buildingsupport space and common areas within the building during Design Development as definedin SECTION 3 MISCELLANEOUS above. Lessor shall integrate the design <strong>of</strong> circulationsystems with building entrances, functional elements, wayfinding systems (refer to Paragraph7.6.2 INTERIOR DESIGN CRITERIA) and signage (refer to Paragraph 7.12 INTERIORSIGNAGE).Circulation system components include entrances, lobbies, corridors, and vertical circulation(stairs and elevators).Refer to Paragraph 3.14 for calculations involving circulation systems in the determination <strong>of</strong>Rentable and Net Usable Area.In Business Occupancies the minimum width <strong>of</strong> corridors within departments or functionalareas shall be 6 feet [1800 mm]; except corridors in Endoscopy Suite, Radiology Service, andSurgery Suite shall be minimum 8 feet [2400 mm] in width. Minimum width <strong>of</strong> major corridorsserving multiple departments and building entrances and lobbies shall be 8 feet [2400 mm] inwidth.Part I: Basic Solicitation Requirements – Page 148 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]In Ambulatory Healthcare Occupancies the Minimum width <strong>of</strong> corridors shall be 8 feet [2400mm].7.1.4 FLOOR-TO-FLOOR HEIGHTSFloor-to-floor heights shall be sufficient to maintain minimum ceiling heights required in thissolicitation (see Schedule E) and to install mechanical and electrical systems above theceiling. Lessor is responsible for coordinating ceiling heights, structural members, space toinstall mechanical and electrical systems, and floor-to-floor heights (see Paragraph "SubmittalRequirements for DD and CD Reviews" for drawings required during design development andconstruction document phases).7.1.5 MATERIALS AND PRODUCTS FOR INTERIOR CONSTRUCTION AND FINISHESA. GeneralThe Lessor shall use materials and products for interior construction that comply with theminimum requirements specified in this solicitation. Materials not definitively specified in thissolicitation shall be manufacturer’s or supplier’s regular production, first quality, and suitablefor commercial use.B. Recycled Contents ProductsThe Lessor shall comply to the extent feasible with the Resource Conservation and RecoveryAct (RCRA), Section 6002, 1976. The Lessor shall use recycled content products as indicatedin this <strong>SFO</strong> and as designated by the U.S. Environmental Protection Agency (EPA) in theComprehensive Procurement Guidelines (CPG), 40 CFR Part 247, and its accompanyingRecovered Materials Advisory Notice (RMAN). The CPG lists the designated recycled contentproducts. EPA also provides recommended levels <strong>of</strong> recycled content for these products.The list <strong>of</strong> designated products, EPA’s recommendations, and lists <strong>of</strong> manufacturers andsuppliers <strong>of</strong> the products can be found at the www.epa.gov/cpg/products.htm website.The Offeror, if unable to comply with both the CPG and RMAN lists, shall submit a request forwaiver for each material to the Contracting <strong>Office</strong>r with the pricing submittal. The request forwaiver shall be based on the following criteria:The cost <strong>of</strong> the recommended product is unreasonable.Inadequate competition exists.Items are not available within a reasonable period <strong>of</strong> time.Items do not meet the <strong>SFO</strong>'s performance standards.C. Environmentally Preferable Building Products and MaterialsThe Lessor shall use environmentally preferable products and materials. The Lessor shallconsider the life-cycle analysis <strong>of</strong> the product in addition to the initial cost.Refer to EPA's environmentally preferable purchasing website, www.epa.gov/epp and USDABioPreferred products website, www.biobased.oce.usda.gov/fb4p/. In general,environmentally preferable products and materials do one or more <strong>of</strong> the following:Part I: Basic Solicitation Requirements – Page 149 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Contain recycled material, are biobased, are rapidly renewable (10-year or shortergrowth cycle), or have other positive environmental attributes.Minimize the consumption <strong>of</strong> resources, energy, and water.Prevent the creation <strong>of</strong> solid waste, air pollution, or water pollution.Promote the use <strong>of</strong> nontoxic substances and avoid toxic materials or processes.The Lessor shall give preference to materials and products that are extracted andmanufactured regionally.7.1.6 MENTAL HEALTHDesign and construct areas to be used by outpatient mental health functions to incorporate thefollowing features.Minimize dead ends or blind spots in corridors.Maximize visibility from staff stations. Place doors in <strong>of</strong>fices where staff will consult with patients so that either patient orstaff can exit the room without having to pass by the other to get out. Based onlayout, this tends to put the door more in the center <strong>of</strong> the room.Patient toilet doors that are in-swinging shall be equipped with hardware that allows them toopen out in an emergency.Glazing: Use laminated (preferred) or tempered glazing materials for all interior and exteriorglazed openings in mental health areas.7.1.7 //SEISMIC DESIGN////Nonstructural elements <strong>of</strong> buildings shall be designed and constructed to resist damagecaused by earthquakes as required by local code and VA Seismic Design Requirements H-18-8.//7.2 PARTITIONSNon-bearing interior partitions shall be capable <strong>of</strong> supporting equipment and furnishingsspecified for the clinic. For interior partition framing use minimum 3-5/8 inch, 20-gauge,galvanized metal studs ASTM C645 with fasteners and accessories complying with ASTM C754. Stud spacing shall be 16-inches on center maximum. For special requirements, useother sizes or systems as appropriate. Where pipe spaces are required, size partition framingthickness to conceal piping. Installation <strong>of</strong> metal studs shall comply with ASTM C754.Provide support required for equipment, furnishings, and work <strong>of</strong> other trades.Use 5/8-inch thick gypsum wallboard ASTM C1396, except for special conditions. Use fireresistant Type X or Type C wallboard ASTM C1396 in fire resistant rated assemblies. Usemoisture resistant wallboard ASTM C620 at wet locations. Provide accessories, fasteners,Part I: Basic Solicitation Requirements – Page 150 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]and finishing materials in accordance with ASTM C1047, C1002, and C840. Install and finishgypsum wallboard in accordance with ASTM C840. Use //Level 5 finish// //Level 4 finish with [insert desired texture here ] texture// for all occupied areas with paint finish. Provide Level 4finish for surfaces to receive Type I vinyl wall coverings or ceramic tile. Provide Level 3 finishfor surfaces to receive Type II vinyl wall coverings. Provide Level 2 finish in rooms or spacesfor which no decorative finish is specified in Schedule E.Provide fire and/or smoke rated partitions that comply with published UL, FM Global, or IBCdesigns.//Where required by Schedule E, provide gypsum veneer plaster system on metal studframing.//Extend all layers <strong>of</strong> gypsum board, on both sides <strong>of</strong> studs, from floor to underside <strong>of</strong> structureabove on the following partitions:Fire rated partitionsSecurity partitions (see Paragraph 4.2.4G)Smoke barriersSound rated partitionsCorridor partitions as required by building codeIn other locations, extend gypsum board from floor to heights as follows:Not less than 4 inches [101.6 mm] above suspended acoustical ceilingsAt ceiling <strong>of</strong> suspended gypsum board // or plaster // ceilingsUse minimum 4-inch solid concrete masonry units for partitions housing service windows <strong>of</strong>Pharmacy, Agent Cashier, and Credit Union.Use lead-lined gypsum wallboard for shielding <strong>of</strong> x-ray rooms. Refer to Paragraph 7.5 below.7.3 INTERIOR DOORS7.3.1 GENERALSchedule E, "Room Finishes, Door and Hardware Schedule" indicates sizes and types <strong>of</strong>doors required. Doors shall be <strong>of</strong> flush design.Fire rated door and frame assemblies shall comply with NFPA 80.Acoustical door and frame assemblies shall provide STC rating specified. Submit certified testreports per ASTM E90.All corridor-to-corridor doors shall have 100 sq. in. glass vision panels and shall swing inopposite directions from each other. Doors in fire partitions and smoke barriers shall have fireratedglazing vision panels and be held open with electromagnetic holders, except doorswhich should remain closed for functional reasons.Part I: Basic Solicitation Requirements – Page 151 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]//Interior Stairway Doors: Provide interior stairway doors with passage latch sets havinginside and outside door handles free at all times. Exceptions are where stairway doors arerequired to be locked to prevent entrance into and elopement from functional departments orareas. Locking shall comply with NFPA 101.//7.3.2 WOOD DOORSInterior wood doors shall be solid core, 1-3/4 inch thick, with [insert grade and species <strong>of</strong>veneers] face veneers for //transparent// //opaque paint// finish.Wood doors shall comply with Window and Door Manufacturer’s Association (WDMA) I.S.1-A,Heavy Duty with Type II adhesives.7.3.3 HOLLOW METAL DOORSHollow metal doors shall be 1-3/4 inch thick and comply with Standard Duty Doors per SteelDoor Institute (SDI) A250.8, Level 1, Model 2; except: Stairwell doors shall comply with Heavy Duty Doors: SDI A250.8, Level 2, Model 2.Security doors (Type 36) shall comply with Extra Heavy Duty Doors SDI A250.8, Level3, Model 2.Detention Doors (Type 22) shall comply with Extra Heavy Duty Doors SDI A250.8,Level 3, Model 2 with core type ‘d’ or ‘f.’7.3.4 HOLLOW METAL DOOR FRAMESA. Frames for Hollow Metal DoorsHollow metal door frames shall comply with Steel Door Institute (SDI) 250 for type and grade<strong>of</strong> doors required (Standard, Heavy Duty, or Extra Heavy Duty) and as follows. Frames shallbe welded construction; knockdown frames are not allowed. Frames for doors specified tohave automatic operators shall be minimum 16-gauge.B. Frames for Wood Doors//Hollow metal door frames shall be shop fabricated, pre-finished, site assembled steel frames.Provide fire rated assemblies where scheduled. Fabricate frames from cold rolled steel ASTMA1008, minimum 18-gauge; casings and trim minimum 20-gauge. Prepare frames for doorhardware. Provide reinforcements for hardware specified.Shop fabricated, pre-finished frames shall not be used for sound rated doors. Provide framescomplying with SDI 114.Shop fabricated, pre-finished frames shall not be used at openings scheduled to receivemortise locksets. Provide frames complying with SDI 250.////Hollow metal door frames shall comply with Steel Door Institute (SDI) 250 for Standard Duty,minimum 18 gauge.//Frames for wood doors specified to have automatic operators shall comply with Steel DoorInstitute (SDI) 250; shall be welded construction; knockdown frames are not allowed; and shallbe minimum 16 gauge.Part I: Basic Solicitation Requirements – Page 152 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]7.3.5 //VAULT DOOR////Provide factory finished vault door complete with frame, hardware, threshold, and day gate.A. DoorFed. Spec. AA D 600, Class 5, // Type IIR (right open swing) // Type IIL (left open swing) //Style H, (Hand change combination lock).B. Combination LockFed. Spec. FF-L-2740, Model HC-(Hand change combination), Class FR-(Front reading),Type Y-(Tube type), Size LD-(Large dial).C. Day GateVault door shall have self-closing metal day gate <strong>of</strong> expanded mesh or solid bars finished tomatch vault door and frame. Furnish gate with an automatic locking device controlled by keyon the outside <strong>of</strong> gate, and thumb throw latch release on the inside <strong>of</strong> the gate, with thumbthrow accessible only to the inside. Key lock to the pharmacy hardware keysets.//7.3.6 AUTOMATIC DOORSAt a minimum, automatic door equipment shall comply with the requirements <strong>of</strong> BuildersHardware Manufacturers Association (BHMA) 156.10. Provide operators which will move thedoors from the fully closed to fully opened position in // three // five // seven // secondsmaximum time interval, when speed adjustment is at maximum setting. Equipment shallconform to UL 325. Provide key operated power disconnect wall switch for each doorinstallation. Automatic door operators and hardware shall be selected and sized appropriatelyfor the door and frame, and for the type and frequency <strong>of</strong> traffic anticipated for the opening.Provide controls to open automatic doors from both sides. Equip controls with safety devicesfor pedestrian protection. Provide door operator controls and equipment that are easilyaccessible for maintenance.Swing door operators shall be <strong>of</strong> institutional type, door panel size 2'-0" to 5'-0" width, weightnot to exceed 600 pounds, electric operated for overhead mounting. Furnish metal mountingsupports, brackets, and other accessories necessary for the installation <strong>of</strong> operators at thehead <strong>of</strong> the door frames. The motor on automatic door operator shall be provided with aninterlock so that the motor will not operate when doors are locked. Operators shall havechecking mechanism providing cushioning action at last part <strong>of</strong> door travel, in both openingand closing cycle. Operators shall be capable <strong>of</strong> recycling doors instantaneously to fully openposition from any point in the closing cycle when control switch is activated. Operators shall,when automatic power is interrupted or shut-<strong>of</strong>f, permit doors to easily open manually withoutdamage to automatic operator system.Sliding doors shall have electric operators, conforming to BHMA A156.10 and the following.Assembly shall be single or bi-parting sliding doors as shown on conceptual drawings. Doorsshall be opened by electric motor pulling door from closed to open position and shall stop doorby electrically reducing voltage and stalling door against mechanical stop. System shall permitmanual control <strong>of</strong> door in event <strong>of</strong> power failure. Opening and closing speeds shall beadjustable. In compliance with NFPA-101, all door panels shall allow "breakout" to the fullyopen position to provide instant egress at any point in the door’s movement.//Automatic doors are required at the following locations:>//Part I: Basic Solicitation Requirements – Page 153 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]//Automatic doors are required at locations indicated in the conceptual drawings and doorschedule.//7.3.7 FINISH HARDWAREComply with requirements specified in "Room Finishes, Door and Hardware Schedule" inSchedule E for door hardware, hardware sets, and installation methods.7.3.8 DOOR IDENTIFICATIONSpecial door identification for handicapped accessibility and hazard warning signs shall beinstalled at all necessary interior room doors. The forms and locations <strong>of</strong> door identificationmust comply with Paragraph 7.12 INTERIOR SIGNAGE. Doors leading into hazardous areasthat might prove dangerous to a blind person shall be made quickly identifiable to the touch byknurling, roughening, or applying an abrasive coating to the surface <strong>of</strong> the knob, door handle,pull, or other hardware. Tactile warning indicators shall not be provided for emergency exitdoors.7.4 NOISE TRANSMISSION CONTROL7.4.1 GENERALProvide sound-resistant construction at the rooms and areas listed in paragraphs below.Submit details <strong>of</strong> sound resistant construction with Second Design Development Submittal.Include test reports for designs or systems to be used. Construct partition, ceiling, and floorsystems to provide necessary performance. Special attention shall be given to preventpossible flanking paths for noise transmission. Verification <strong>of</strong> noise transmission control shallbe included in building commissioning.Sound damping in meditation rooms, quiet rooms, and similar areas shall be provided by finishmaterials shown for these areas in Schedule E, "Room Finishes, Door, & Hardware Schedule."Where an area generating unusual noise or vibration is located adjacent to occupied spaces,the Lessor’s A/E shall obtain the services <strong>of</strong> a pr<strong>of</strong>essional acoustical consultant to design thesound suppression measures required to produce a comfortable working environment in theadjacent spaces.7.4.2 SOUND TRANSMISSION CLASS (STC) 45The sound resistant enclosures (partitions, doors, duct system) <strong>of</strong> the spaces listed belowshall be designed to suppress generated noise and provide a satisfactory degree <strong>of</strong> acousticalisolation for adjacent occupied spaces. A minimum Sound Transmission Class (STC) rating <strong>of</strong>45 shall be achieved.A/C and other mechanical equipment roomsEmergency generator rooms//Auditoriums////Multipurpose Rooms////Mental Health Group Therapy rooms////[__________]// [insert other spaces as required by clinic program]Part I: Basic Solicitation Requirements – Page 154 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]7.4.3 SOUND TRANSMISSION CLASS (STC) 40The sound resistant enclosures <strong>of</strong> the following spaces shall be designed to assure speechprivacy and achieve an STC rating <strong>of</strong> 40.Conference roomsConsultation <strong>of</strong>ficesExamination and treatment rooms//Individual <strong>of</strong>fices in Mental Health and Behavioral Sciences Service//Audiology and Speech Pathology areas//Benefits Counselors—VBA Regional <strong>Office</strong>s//// [insert other spaces as required by clinic program ] //7.5 X-RAY RADIATION SHIELDING AND RADIOGRAPHIC ROOMS7.5.1 X-RAY RADIATION SHIELDINGA. GeneralProvide shielding against radiation from x-ray equipment. When required by State or Localjurisdictions, obtain the services <strong>of</strong> a physicist approved by the American Board <strong>of</strong> Radiologyin accordance with the appropriate standards and regulations <strong>of</strong> the National Council onRadiation Protection and Measurements (obtainable from NCRP Publications; 7910Woodmont Avenue, Suite 400; Bethesda, MD; 20814) to design and specify the level <strong>of</strong>radiation protection required.State the prescribed shielding in terms <strong>of</strong> millimeters <strong>of</strong> lead or in inches <strong>of</strong> wall, ceiling, floor,and door construction <strong>of</strong> equivalent protection thickness. Post a certificate, stating the leadequivalent protection <strong>of</strong> each surface, in all rooms with radiation shielding.B. Lead Lined Doors and FramesLead lining <strong>of</strong> frames, doors and other items occurring in partitions shall provide an x-rayabsorption equivalent to that <strong>of</strong> partitions in which they occur.(1) Lead Lined Wood DoorsUse flush veneered construction.Face veneers shall be same species and grade as used for other wood doors in theproject.Construct doors <strong>of</strong> two separate solid wood cores with a single sheet <strong>of</strong> lead liningthrough center.Extend sheet lead lining to all door edges, providing x-ray absorption equal to partitionin which door occurs.Fasten wood cores together with either countersunk steel bolts through lead with boltheads and nuts covered with poured lead, or with poured lead dowels.Finish face <strong>of</strong> dowels and lead covering <strong>of</strong> bolt heads and nuts flush with wood cores.Edge strips: Use same species <strong>of</strong> wood as face veneer.Minimum thickness shall be 1-1/2 inches at top edge and 2-1/2 inches at bottom edge.Extend vertical edge strips full height <strong>of</strong> door and bevel 1/8-inch for each two inches <strong>of</strong>door thickness.Part I: Basic Solicitation Requirements – Page 155 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Hardware for lead lined doors is specified in Schedule E. Make total thickness <strong>of</strong> sheet leadused for lining hardware equivalent to thickness <strong>of</strong> sheet lead core <strong>of</strong> door.7.5.2 DESIGN FOR RADIOGRAPHIC EQUIPMENT//Rooms containing radiographic equipment shall be designed to be shelled in and finish workscheduled for completion as late as possible in the construction process.////Rooms containing radiographic equipment shall be designed for a generic installation systemthat can accept and accommodate all vendors’ radiology equipment (DOD/VA Universal X-Ray (R-F) Room). Design and construct room(s) in accordance with requirements shown onconceptual drawings.//The structural support for overhead radiology equipment shall be designed such thatmovement <strong>of</strong> the radiology equipment ceiling-mounted support rails shall not exceed 0.2 in[5 mm] in any direction.For a list <strong>of</strong> work items and materials required for the completion <strong>of</strong> rooms with radiographicequipment, refer to Schedules B and C <strong>of</strong> this solicitation. The Lessor will be required toprovide unit costs for these items.7.5.3 SPECIAL X-RAY CONTROL ROOM REQUIREMENTSProvide single pane viewing windows <strong>of</strong> conventional lead glass for x-ray control rooms.Where the control room projects into and is located near the corner <strong>of</strong> the diagnostic x-rayroom, the projecting control room partition shall have a portion <strong>of</strong> wall angled toward the x-raywork space. Locate the viewing window in this angled section.To allow for clearance for x-ray tube crane travel, do not exceed a height <strong>of</strong> 7' 6" above thefloor for that portion <strong>of</strong> the shielded partition <strong>of</strong> a control room which projects into a diagnosticx-ray room. Feed all electric service, located in or on the projecting control room partition, upfrom the floor or horizontally from the wall where the control room projects. Leave the spaceabove the projecting control area clear to allow x-ray equipment to traverse.7.6 INTERIOR FINISHES7.6.1 GENERALInterior finishes are prescribed in "Room Finishes, Door and Hardware Schedule" in ScheduleE <strong>of</strong> this Solicitation. VA must review and approve any deviation from this document prior tostart <strong>of</strong> final construction documents.The Interior Design concept and materials, finishes, colors, patterns and textures must beapproved by the Contracting <strong>Office</strong>r. Submit sample boards for review and approval byContracting <strong>Office</strong>r with 75% construction documents (Paragraph 3.20.4).Finish materials, including vinyl wall covering, vinyl composition tile flooring, sheet vinyl,carpet, and ceramic wall and floor tile finish, as specified herein, shall be included in the rentalrate. An estimate <strong>of</strong> base quantities <strong>of</strong> finish material that should be included in the proposedrental rate is indicated on Schedule C in this solicitation. Adjustments will be made at the endPart I: Basic Solicitation Requirements – Page 156 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]<strong>of</strong> the construction based on actual measurement. Payment will be made per the prenegotiatedunit cost for these items.7.6.2 INTERIOR DESIGN CRITERIAA. GoalTo provide a supportive interior environment that is conducive to healing both the patient’smind and body, is respectful <strong>of</strong> the public monies, promotes staff performance, and expressesprogressive high quality design.B. ConceptThe design is to pivot from the facility’s mission and its patient pr<strong>of</strong>ile. This includes a workingknowledge <strong>of</strong> the pr<strong>of</strong>ile and characteristics <strong>of</strong> the veteran as a patient population and thedistinct pr<strong>of</strong>ile <strong>of</strong> the users <strong>of</strong> said facility and said project. VA patients are <strong>of</strong>ten long-term,high repeaters with multi-medical problems. Each user group will reveal the degree <strong>of</strong> needfor the design to address aging, physical and mental disabilities, abusiveness, loss <strong>of</strong> functionand perceptual ability.C. FunctionFunctional requirements dictate maintainable colors, textures, patterns, material selections,combination <strong>of</strong> materials, and installation techniques. Materials must be chosen for longevityand good appearance retention.D. Signage and WayfindingA "wayfinding" process needs to be designed into every project. Patients, visitors, and staffneed to know where they are, what their destination is, how to get there, and how to return totheir origination point. Identification, personalization <strong>of</strong> occupied spaces, and orientation areall to be addressed in the design. Wayfinding is to be thought <strong>of</strong> broadly as building elements,color, texture, and pattern cues, as well as a coordinated set-up for separate contactedsignage and artwork.E. GuidelinesDesign attention shall be given to all spaces. Areas which could initiate the design may be thelobby or administrative suite, but extensions <strong>of</strong> the same quality and variety are required forthe corridors, staff areas, and patient areas. The design must <strong>of</strong>fer a distinctive and clear leadfor the planning and selecting <strong>of</strong> interior furnishings. Designs that narrow choices <strong>of</strong>procurement furnishings are inappropriate. A working understanding <strong>of</strong> the limits <strong>of</strong>government sources is to be considered. This consideration will produce a good environmentfor the furnishings.Designs that use "lifetime <strong>of</strong> the building" materials in colors, patterns, and designs thattranscend time are endorsed. Trendy colors and patterns are to be restricted to cyclereplacement materials, such as paint and wall coverings.7.7 CEILINGS7.7.1 ACOUSTICAL CEILINGSCeiling suspension system shall be //intermediate-duty// //heavy-duty// system. //Providealuminum suspension system in kitchen.//Part I: Basic Solicitation Requirements – Page 157 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Acoustical units shall be mineral fiber units that provide a noise reduction coefficient (NRC) <strong>of</strong>at least 0.55 and a ceiling attenuation class (CAC) rating <strong>of</strong> at least 33. Provide units withmanufacturer’s standard white painted finish, except provide membrane faced (mylar) units in//kitchen and other //locations scheduled for non-absorbent, scrubbable finish. Ceiling unitsshall have a flame-spread <strong>of</strong> 25 or less and a smoke development rating <strong>of</strong> 50 or less (ASTME-84).7.7.2 CUBICLE CURTAIN TRACKSProvide cubicle curtain tracks with carriers and hooks in exam rooms and other locationsindicated in Schedule B for privacy.Provide surface-mounted tracks <strong>of</strong> extruded aluminum, ASTM B221, alloy 6063, temper T5 orT6, channel shaped, with smooth inside raceway for curtain carriers. End stop connectors,ceiling flanges and other accessories shall be fabricated from the same material with the samefinish as the tracks or from nylon.Curtain carriers shall be nylon or delrin, with either nylon or delrin wheels on metal, delrin, ornylon axles. Equip each carrier with either stainless steel, chromium-plated brass or steelhooks with swivel, or nickel chromium-plated brass or stainless steel bead chain and hookassembly. Alternatively, delrin carriers may have molded-on delrin hooks. Hook for beadchain may be the same material and finish as the bead chain or may be chromium-platedsteel. Provide 2.2 carriers for every foot (or fraction there<strong>of</strong>) <strong>of</strong> each section <strong>of</strong> each tracklength, plus one additional carrier.At end <strong>of</strong> each section <strong>of</strong> track, make provision for insertion and removal <strong>of</strong> carriers. Design toprevent accidental removal <strong>of</strong> carrier. Any operating mechanism shall be removable withcommon tools.VA will supply and maintain fabric cubicle curtains.7.8 FLOORINGAn estimate <strong>of</strong> base quantities <strong>of</strong> each type <strong>of</strong> flooring that should be included in the proposedrental rate is indicated in Schedule C. Adjustments will be made at the end <strong>of</strong> the constructionbased on actual measurement and payment will be made per the pre-negotiated unit cost forthese items.Flooring material specifications and installation methods shall conform to the requirements <strong>of</strong>this <strong>SFO</strong> and referenced national standards. Under floor concrete must be smooth and level.Patching and leveling compounds containing gypsum are prohibited. When floor coveringsare newly installed or changed, samples must be approved in advance by the Contracting<strong>Office</strong>r.Unless other material is scheduled for a room or area, perimeter base shall be rubber or vinylcomplying with ASTM F1861. Base shall be 1/8-inch thick, 4 inches high with molded top.Style B (cove) shall be used throughout.Part I: Basic Solicitation Requirements – Page 158 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]7.8.1 MEMBRANE WATERPROOFING AT INTERIOR FLOOR DRAINSProvide membrane waterpro<strong>of</strong>ing under floor finishes surrounding floor drains in areas subjectto wet conditions to prevent water and moisture from penetrating the underlying floor slabsand damaging the finishes and contents <strong>of</strong> the rooms or spaces below. Attach the membranewaterpro<strong>of</strong>ing to the floor drain by a clamp, extend outward from the floor drain under theentire area <strong>of</strong> the surrounding floor finish surface or concrete topping which slopes toward thefloor drain or which is subject to surface water, and carry up abutting vertical surfaces at least3 in [76.2 mm].Do not provide membrane waterpro<strong>of</strong>ing if either:The floor slab is placed on grade.The floor finish itself is latex mastic with waterpro<strong>of</strong>ing membrane.7.8.2 FLOOR SLAB DEPRESSIONSFloor slab depressions are required in specific areas or rooms for the purpose <strong>of</strong> providingslopes in floors to:Direct water into drains.Provide for special floor finishes that require a setting bed.It is the responsibility <strong>of</strong> the Lessor to ensure that depressions are provided to suit the actualfinishes and equipment provided, and to satisfy the actual conditions required by the design.Liquid applied water pro<strong>of</strong>ing shall be latex based water pro<strong>of</strong>ing membrane, ANSI A118.10;ready to use liquid latex compatible with Cement Backer Boards and tile setting mortars.Reinforcing fabric shall be alkali-resistant glass fiber. Final Performance shall be as follows inconformance with ANSI A118.10:Waterpro<strong>of</strong>ing ability (ASTM D 4068)Seam strength and breaking strength (ASTM D751)Seam strength and breaking strength (ASTM D751)Dimensional stability (ASTM D1204)Shear strength to ceramic tile (ASTM C482)Fungus and microorganism resistance (ASTM G21-96)Conforms (no water penetration)Conforms (no water penetration)ConformsConformsConformsConforms7.8.3 FLOORING, CERAMIC TILEUnglazed ceramic mosaic tile shall be used in all toilets and other areas specified in ScheduleE. Provide slab depressions, setting beds and waterpro<strong>of</strong> membrane per Paragraph 7.8.2.//Provide quarry tile in areas designated in Schedule E.//Comply with ANSI A137.1, Standard Grade, and as follows. Coefficient <strong>of</strong> friction, whentested in accordance with ASTM C1028, shall provide the following level <strong>of</strong> performance:Not less than 0.7 (wet condition) for bathing areas.Not less than 0.8 on ramps for wet and dry conditions.Not less than 0.6 for wet and dry conditions for other areas.Part I: Basic Solicitation Requirements – Page 159 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]7.8.4 FLOORING, VINYL TILE AND SHEET VINYLA. Vinyl Composition TileVinyl composition floor tile (VCT) ASTM F1066, Composition 1, Class 2 (through pattern), 1/8-inch thick, 12 inches square, shall be provided at locations in Schedule E.B. Resilient Sheet FlooringResilient Sheet Flooring (RSF) shall be provided at locations listed in Schedule E. //Rooms toreceive RSF shall have 6-inch integral cove base (flash coving).// RSF shall conform to ASTMF1913 and material requirements specified in ASTM F1303 for sheet vinyl flooring, Type II,Grade 1, backing classification not applicable. Foam-backed sheet flooring is not acceptable.Use smooth face, minimum thickness nominal 0.08 inch. Provide maximum size sheetmaterial produced by manufacturer to provide minimum number <strong>of</strong> joints; minimum widthacceptable 48 inches. Each color and pattern <strong>of</strong> sheet flooring shall be <strong>of</strong> same productionrun.C. Welded Seam Sheet FlooringWelded Seam Sheet Flooring (WSF) shall be provided at locations listed in Schedule E.Rooms to receive WSF shall have 6-inch integral cove base (flash coving). WSF shallconform to ASTM F1303 for sheet vinyl flooring, Type II, Grade 1, except for backingrequirements. Flooring shall be homogeneous through full thickness; backed sheet flooring isnot acceptable. Minimum nominal thickness is 0.08 in [2 mm]; minimum width, 6 feet [18 m].Each color and pattern <strong>of</strong> sheet flooring shall be <strong>of</strong> same production run. Welding rod shall beproduct <strong>of</strong> floor covering manufacturer; color <strong>of</strong> welding rod shall match field color <strong>of</strong> sheetvinyl.7.8.5 //FLOORING, RUBBERRubber tile shall conform to ASTM F1344, Class 1, homogenous rubber tile, through mottled,//12 inches// //24 inches// square, thick; color and pattern uniformly distributed throughout tile.Molded pattern wearing surface base thickness shall be 1/8-inch thick. Where rubber tile isused, provide tiles with a minimum <strong>of</strong> 90% post consumer rubber.Resilient treads shall conform to Fed. Spec. RR-T-650, Composition A, Type 2,-3/16 inchthick on wear surface tapering to 1/8-inch thick at riser end. Nosing shape shall to conform tosub-tread nosing shape.Sheet rubber flooring shall conform to ASTM F1344, F1859 or F1860, 36 inches wide, 1/8-inchthick, //smooth face// //patterned face//, material by the same manufacturer as the rubbertreads, color and pattern to match treads. Provide rubber flooring made with a minimum <strong>of</strong>90% consumer rubber where possible.//7.8.6 FLOORING, CARPETA. CarpetNew broadloom carpet shall be used as floor covering areas indicated in Schedule E. Thesuccessful Offeror/Lessor shall submit carpet samples and specifications.//Provide new carpet tile as floor covering in those areas indicated in Schedule E <strong>of</strong> thisSolicitation//Part I: Basic Solicitation Requirements – Page 160 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY](1) Physical CharacteristicsCarpet shall be free <strong>of</strong> visual blemishes, streaks, poorly-dyed areas, fuzzing <strong>of</strong> pile yarn, spotsor stains, and other physical and manufacturing defects.Carpet shall be manufacturer’s standard construction commercial carpet:Broadloom; maximum width to minimum use//Modular Tile: 24 in [600 mm] square tile.//Provide static control to permanently control static build up to less than 2.0 kV when tested at20% relative humidity and 70 ˚F [21 ˚C] in accordance with AATCC 134.Pile Height: Maximum 0.10 in [3.25 mm].Pile Fiber: Nylon with recycled content 25% minimum branded (federally registeredtrademark).Pile Type: Level Loop.Backing materials: Manufacturer’s unitary backing designed for glue-down installation usingrecovered materials.Appearance Retention Rating (ARR): Carpet shall be tested and have the minimum 3.5-4.0Severe ARR when tested in accordance with either the ASTM D 5252 (Hexapod) or ASTM D5417 (Vettermann) test methods using the number <strong>of</strong> cycles for short and long term tests asspecified.Tuft Bind: Minimum force <strong>of</strong> 40 N (10 lb) required to pull a tuft or loop free from carpetbacking. Test per ASTM D1335.Colorfastness to Crocking: Dry and wet crocking and water bleed, comply with AATCC 165Color Transference Chart for colors, minimum class 4 rating.Colorfastness to Ozone: Comply with AATCC 129, minimum rating <strong>of</strong> 4 on the AATCC colortransfer chart.Delamination Strength: Minimum <strong>of</strong> 440 N/m (2.5 lb/inch) between secondary backing.Flammability and Critical Radiant Flux Requirements: Test Carpet in accordance withASTM E 648: Class I: Not less than 0.45 watts per square centimeter.Corridors, lobbies, entrances, common areas or multipurpose rooms, open <strong>of</strong>fices, waitingareas and dining areas: Minimum APYD 6000.Other areas: Minimum APYD 4000.VOC Limits: Use carpet that complies with the testing and product requirements <strong>of</strong> the Carpetand Rug Institute’s Green Label Program. Use carpet adhesives that comply with the productrequirements <strong>of</strong> the South Coast Air Quality <strong>Management</strong> District (SCAQMD), rule #1168.B. InstallationCarpet shall be a direct glue down installation following the manufacturer's instructions. Allpatterns and/or stripes shall match. A seam layout plan shall be provided for broadloom toassure that seams are located out <strong>of</strong> major traffic patterns.Part I: Basic Solicitation Requirements – Page 161 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]C. ReplacementCarpet must be replaced at anytime during the lease when it cannot be satisfactorily cleaned,stains removed or when excessive wearing or tearing occurs or unsightly seaming is noticed.The determination will be made by the Contracting <strong>Office</strong>r. At a minimum, the carpet will bereplaced every eight (8) years. All replacement work will be done after hours at the Lessor’sexpense, including moving and replacing furniture.D. Samples for Color SelectionWhen carpet must be newly installed or be changed, the Lessor will provide the Government aminimum <strong>of</strong> four samples <strong>of</strong> carpeting which vary in color. The color selected shall have theability to disguise soil in entrance areas and wax-track <strong>of</strong>f in areas adjacent to vinylcomposition. A small pattern, tweed, or heather effect is most desirable. The sample andcolor must be approved by the Contracting <strong>Office</strong>r prior to installation. No substitution will bemade by the Lessor after sample selection.7.8.7 //FLOORING, LATEX MASTICTraffic-bearing, trowel-applied, vinyl resin, neoprene resin, or polyacrylate resin flooringsystem, latex mastic (LM) shall be provided at locations listed in Schedule E. A reinforcedelastomeric waterpro<strong>of</strong> membrane is not required for slab-on-grade installations <strong>of</strong> latexmastic.A. Latex Mastic FlooringMil. Spec. MIL D 3l34, Type II.B. Waterpro<strong>of</strong> MembraneShall consist <strong>of</strong> a neoprene emulsion or elastomeric polyurethane resin reinforced withfiberglass net or cloth.//7.8.8 //COMPUTER ROOM FLOORINGAccess flooring shall consist <strong>of</strong> a series <strong>of</strong> modular, removable, interchangeable panels on anelevated support system forming an accessible underfloor cavity to accommodate electricaland mechanical services. Depress the structural floor slab a minimum <strong>of</strong> 18 inches[457.2 mm]. Where slab depressions are not possible, provide access floor system 18 inches[457.2 mm] above the structural floor. Minimum clear ceiling height shall not be reducedfor raised floor installations. Ceiling height shall be measured from top <strong>of</strong> access floor tounderside <strong>of</strong> suspended acoustical ceiling. Provide ramp access at a maximum 1:12 slope forraised floor systems. //An access floor system constructed in existing buildings should providea minimum <strong>of</strong> 12 inches [304.8 mm] clear space.//System shall be filled, formed, or cast gravity-held panels on snap-on stringer understructure //gravity-held panels on bolted stringer understructure. All panels shall be interchangeableexcept those altered to meet special conditions.Concentrated-Load Performance: Provide floor panels, including those with cutouts,capable <strong>of</strong> withstanding a concentrated design load <strong>of</strong> the following magnitude, with a topsurfacedeflection under load and a permanent set not to exceed, respectively, 0.080 inch and0.010 inch [2.03 and 0.25 mm], according to CISCA A/F, Section I, "Concentrated Loads:"1000 lbf.Ultimate-Load Performance: Provide access flooring systems capable <strong>of</strong> withstanding aminimum ultimate concentrated load equal to value obtained by multiplying specifiedPart I: Basic Solicitation Requirements – Page 162 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]concentrated floor panel design load by a factor <strong>of</strong> 2.5, without failing, according to CISCAA/F, Section II, "Ultimate Loading." Failure is defined as the point at which access flooringsystem will not take any additional load.Rolling-Load Performance: Provide access flooring systems capable <strong>of</strong> withstanding rollingloads <strong>of</strong> the following magnitude applied to non-perforated panels, with a combination <strong>of</strong> localand overall deformation not to exceed 0.040 inch [1.02 mm] after exposure to rolling load overCISCA A/F Path A or B, whichever path produces the greatest top-surface deformation,according to CISCA A/F, Section III, "Rolling Loads:" Wheel 1 Rolling Load: 600 lbf.Pedestal Axial-Load Performance: Provide pedestal assemblies, without panels or othersupports in place, capable <strong>of</strong> withstanding a 5000 lbf axial load per pedestal, according toCISCA A/F, Section V, "Pedestal Axial Load Test."Pedestal Overturning-Moment Performance: Provide pedestal assemblies, without panelsor other supports in place, capable <strong>of</strong> withstanding an overturning moment per pedestal <strong>of</strong>1000 lbf x inches, according to CISCA A/F, Section VI, "Pedestal Overturning Moment Test."Stringer Concentrated-Load Performance: Provide stringers, without panels in place,capable <strong>of</strong> withstanding a concentrated load <strong>of</strong> 200 lbf at center <strong>of</strong> span with a permanent setnot to exceed 0.010 inch, as determined per CISCA A/F, Section IV, "Stringer Load Testing."Floor Panel Impact-Load Performance: Provide access flooring system capable <strong>of</strong>withstanding an impact load <strong>of</strong> // 334 N (75 lbf) // 445 N (100 lbf) // 566 N (125 lbf) // 667 N(150 lbf) // 778 N (175 lbf) // when dropped from 36 inches [914 mm] onto a 1 sq in [6.5 sq cm]area located anywhere on panel, without failing. Failure is defined as collapse <strong>of</strong> accessflooring system.Installed access floor shall be level within plus or minus 1 in 2000 (0.060 inches in 10 feet),and plus or minus 0.10 inches [2.5 mm] over the entire area. Floor assembly to be rigid, free<strong>of</strong> vibration, rocking panels, rattles, and squeaks.Leakage: Air leakage through the joints between panels and around the perimeter <strong>of</strong> the floorsystem not to exceed 2 cu ft [0.057 cu m] <strong>of</strong> air per minute per linear foot [300 mm] <strong>of</strong> jointsubjected to 0.5 inch, water gage [125 Pa] positive pressure in the plenum.Grounding: Components shall be in direct positive contact for safe continuous electricalgrounding <strong>of</strong> the entire floor system.Panel to Understructure Resistance: Not more than 10 ohms.Static Electricity Control: The acceptable resistance range is from not less than 0.5megohms minimum to not more than 20,000 megohms maximum. Maximum electricalresistance shall be measured from the top <strong>of</strong> the panel to the grounded subfloor. Exposedmetal will not be allowed at the wearing surface <strong>of</strong> the floor.Floor Panels: Construct panels to be uniform in face dimensions and to be square within atolerance <strong>of</strong> plus or minus 0.015 inches [3.8 mm]; and flatness within a tolerance <strong>of</strong> plus orminus 0.02 inches [0.5 mm]. Design individual floor panels to be easily placed and removed,without disturbing adjacent panels or understructure, by one person using a tool furnished bythe access floor manufacturer. Panels shall be 24 inches x 24 inches [600 mm x 600 mm] insize.Part I: Basic Solicitation Requirements – Page 163 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Filled Formed-Steel Panels: These shall be option <strong>of</strong> panel construction and are describedbelow:Particleboard core panels not less than one inch thick laminated to top and bottom facesheets <strong>of</strong> zinc-coated steel not less than 0.0179 inches [0.45 mm] thick. Enclose edges <strong>of</strong>core with upturned, die-formed edge <strong>of</strong> bottom sheet or with perimeter channel welded totop and bottom sheets.Cementitious-filled panels fabricated with die-cut flat top sheet and die-formed and stiffenedbottom pan formed from cold-rolled steel sheet joined together by resistance welding t<strong>of</strong>orm an enclosed assembly, with metal surfaces protected against corrosion bymanufacturer's standard factory-applied finish.Lightweight concrete filled panels fabricated with flat top sheet and bottom pan formed fromelectrolytic-zinc-coated, cold-rolled steel sheet joined together permanently and structurallyby hemming and joined to concrete core by adhesive to form an enclosed assembly.Provide perimeter <strong>of</strong> panels with continuous extruded conductive vinyl edge strips. Top edge<strong>of</strong> strip to be flush with panel floor finish. Mechanically lock edge strips and fasten in placewith adhesive.Perforated Panels: Flat, perforated top surface with holes or slots <strong>of</strong> number, spacing, andsize standard with manufacturer. Fabricate cut-outs in floor panels to accommodate cablepenetrations and service outlets. Provide reinforcement or additional support to make panelswith cut-outs perform the same as solid uncut panels. Fit cut-outs with manufacturer’sstandard grommet. Provide foam-rubber pads for sealing annular space formed in cutouts bycables and trim edge <strong>of</strong> cutout with molding having flange and ledge for capturing andsupporting pads.//7.9 WALL COVERINGSWalls shall be covered in accordance with "Room Finish Schedule" in Schedule E, or otherrequirements <strong>of</strong> this Solicitation. An estimate <strong>of</strong> base quantities <strong>of</strong> each type <strong>of</strong> wall coveringthat should be included in the proposed rental rate is indicated in Schedule C. Adjustmentswill be made at the end <strong>of</strong> construction based on actual measurement and payment will bemade per the pre-negotiated unit cost for these items. Colors and patterns shall be asselected or approved by the Contracting <strong>Office</strong>r.7.9.1 CERAMIC WALL TILECeramic wall tile shall be glazed tile. Ceramic tile at showers and wet locations shall beinstalled over cement backer board or Portland cement mortar on metal lath.Comply with ANSI A137.1, Standard Grade; cushion edges; //matte// //gloss// glazing. Trimshapes shall conform to applicable requirements <strong>of</strong> adjoining floor and wall tile. Provide coveand bullnose shapes where shown, and required to complete tile work.Cementitious backer units shall comply with ANSI A118.9.Part I: Basic Solicitation Requirements – Page 164 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]A. Vinyl Wallcovering (W)Vinyl wall covering shall comply with CFFA-2575. Fungi-resistance rating shall be 0 inaccordance with ASTM G21. Provide factory-applied clear delustered polyvinyl-fluoride (PVF)coating minimum ½ mil [0.0125 mm] thickness. Do not include PVF coating weight inminimum total weight. Fire hazard classification with PVF coating shall be Class A.//Type I (Light Duty) //.//Type II (Medium Duty) //.Adhesive shall be vermin and mildew resistant.B. //Wallpaper BordersWallpaper borders shall be installed in spaces indicated in Schedule E. Borders shall be vinylcoated, 10 inches [254 mm] in width.C. Protective Wallcovering (WP)Wainscot <strong>of</strong> rigid PVC protective wall covering (WP) shall be installed on walls in corridors andother locations in accordance with Schedule E.Provide rigid, embossed, impact-resistant protective wallcovering <strong>of</strong> PVC plastic sheets or rollstock. Material shall have following minimum properties: Thickness: //0.028 inch// //0.035inch// //0.060 inch// //0.080 inch//; Roll Width: 48 inches [1200 mm]; or Sheet Size: 48" x 96"[1200 mm x 2400 mm]; Flame/Smoke Ratings: ASTM E 84, Class A; Flame Spread 0-25;Smoke Developed 0-450. Provide accessories: color matched rigid vinyl moldings and trim;acrylic latex primer/sealer, and mildew-resistant adhesives and caulk. Materials shall becadmium and mercury free.7.9.2 MAINTENANCE AND REPLACEMENTAll wall covering is to be maintained in "like new" condition for the life <strong>of</strong> the lease. Wallcovering must be replaced or repaired at the Lessor's expense, including moving andreplacing furnishings (except where wall covering has been damaged due to the negligence <strong>of</strong>VA), anytime during the occupancy by VA if it is torn, peeling, or permanently stained.Ceramic tile must be replaced or repaired if it is loose, chipped, broken, or permanentlydiscolored. All repair and replacement work is to be done after working hours.7.10 PAINTINGA. GeneralPainting shall include field application <strong>of</strong> paints, stains, epoxies, and other coatings forsurfaces and materials not supplied with factory finish or otherwise pre-finished. Paintingincludes shellacs, stains, varnishes, coatings specified, striping or markers, and identitymarkings. Wall surfaces shall be painted throughout, except where wall coverings perParagraph 7.9 above are called for in "Room Finish Schedule" in Schedule E.Immediately prior to VA occupancy, all surfaces designated by VA for painting must be newlypainted in colors acceptable to VA. At a minimum, all painted surfaces including public areasmust be repainted after working hours at the Lessor's expense every three (3) years. Thisincludes moving and replacement <strong>of</strong> furniture.Part I: Basic Solicitation Requirements – Page 165 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]B. SubmittalsBefore work is started, or sample panels are prepared, submit manufacturer's literatureindicating brand label, product name, and product code as <strong>of</strong> the date <strong>of</strong> contract award. Eachcoating system is to be from a single manufacturer. All coats on a particular substrate must befrom a single manufacturer.Sample Panels: After painters' materials have been approved and before work is started,submit sample panels showing each type <strong>of</strong> finish and color specified. Panels to show colorshall be composition board, 4 inch x 10 inch x 1/8 inch [101.6 mm x 254 mm x 3.175 mm];Panels to show transparent finishes shall be wood <strong>of</strong> same species and grain pattern as woodapproved for use, 4 inch x 10 inch face x 1/4 inch [101.6 mm x 254 mm x 6.35 mm] thickminimum.C. ProductsProvide the best quality grade <strong>of</strong> the various types <strong>of</strong> painting materials and coatings asregularly manufactured by acceptable paint manufacturer. Materials not displaying themanufacturer’s identification as a standard, best-grade product will not be acceptable. Paintproducts <strong>of</strong> the following manufacturers are acceptable:Dunn-EdwardsFrazeeICISherwin-WilliamsUse primers with pigment and vehicle recommended by top coat manufacturer as compatiblewith substrate and finish coats specified. Use only thinners approved by the paintmanufacture and use only within recommended limits.Use ready-mixed (including colors), except two component epoxies, polyurethanes,polyesters, paints having metallic powders packaged separately, and paints requiring specifiedadditives.Paint materials shall conform to the restrictions <strong>of</strong> the local Environmental and Toxic Controljurisdiction. Volatile Organic Compounds (VOC) content <strong>of</strong> paint materials shall not exceedlocal, state or district requirements. Lead-base paints shall not be used. Materials shall notcontain asbestos, zinc-chromate, strontium-chromate, cadmium, mercury or mercurycompounds, or free crystalline silica. Materials shall not contain any <strong>of</strong> the ACGIH-BKLT andACGHI-DOC confirmed or suspected human carcinogens.D. ApplicationUnless otherwise specified, apply paint in three coats: prime, body, and finish. When twocoats applied to prime coat are the same, the first coat applied over primer is body coat andthe second coat is the finish coat. Apply each coat evenly and cover substrate completely.Finish surfaces to show solid even color, free from runs, lumps, brushmarks, laps, holidays, orother defects.E. Paint ScheduleGypsum Wallboard, except where epoxy coating (SC) is required:1 coat primer sealer applied prior to texturing1 coat pigmented sealer/primer2 coats acrylic latex enamel //low luster// //semi-gloss// //gloss//Part I: Basic Solicitation Requirements – Page 166 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Gypsum Wallboard epoxy coating, (SC):1 coat primer sealer2 coats waterborne epoxy //semi-gloss// //gloss//Ferrous and Galvanized Metal:1 coat vinyl acrylic primer or vinyl pre-wash primer (if not factory-primed)2 coats acrylic latex enamel //low luster// //semi-gloss// //gloss//Wood – Transparent Finish:Provide hand-wiped stained finish, water-based, clear acrylic, premium grade //glossand color as selected// //[specify gloss and color//Stain2 coats clear finish7.11 HANDRAILS, WALL GUARDS AND CORNER GUARDSAn estimate <strong>of</strong> base quantities <strong>of</strong> each type <strong>of</strong> handrail, wall guard, and corner guard thatshould be included in the proposed rental rate is indicated in Schedule C. Adjustments will bemade at the end <strong>of</strong> the project based on actual measurement and payment will be made perthe pre-negotiated unit cost for these items.Stainless steel shall conform to ASTM A167, Type 302B. Extruded aluminum componentsshall conform to ASTM B221, Alloy 6063, Temper T5 or T6. Resilient materials shall beextruded and injection molded acrylic vinyl or extruded polyvinyl chloride meeting followingrequirements:Minimum impact resistance <strong>of</strong> 2150 ft-lbs [200 Nm] (when tested in accordance withASTM D256 (Izod impact, ft-lbs per inch notch).Class 1 fire rating when tested in accordance with ASTM E84, having a maximumflame spread <strong>of</strong> 25 and a smoke developed rating <strong>of</strong> 450 or less.shall be rated self extinguishing when tested in accordance with ASTM D635Material shall be labeled and tested by Underwriters Laboratories or other approvedindependent testing laboratory.Provide resilient materials with integral color with all colored components matched inaccordance with SAE J 1545 to within plus or minus 1.0 on the CIE LCH scales.7.11.1 HANDRAILS AND WALL GUARDSExcept in administrative areas, provide handrails and wall guards on both sides <strong>of</strong> allcorridors. Provide chair rail at locations indicated in Schedule C. Provide continuousreinforcing in the wall attachment <strong>of</strong> handrails and bumper guards.Handrail/Wall Guard Combination shall consist <strong>of</strong> snap-on covers <strong>of</strong> resilient material,minimum 0.078-inch thick, free-floated on a continuous, extruded aluminum retainer, minimum0.072-inch thick, anchored to wall at maximum 32 inches on center.Part I: Basic Solicitation Requirements – Page 167 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Wall Guards (Crash Rails) shall consist <strong>of</strong> snap-on covers <strong>of</strong> resilient material, minimum0.110-inch thick, free-floated over a continuous extruded aluminum retainer, minimum 0.090-inch thick anchored to wall at maximum 24 inches on center.7.11.2 CORNER GUARDSResilient, shock-absorbing corner guards shall be // flush mounted // surface mounted // type<strong>of</strong> // 1-1/4 inch [31.75 mm] radius // ¼-inch [6.35 mm] corner //. Snap-on corner guards shallbe formed from resilient material, minimum 0.078-inch [1.98 mm] thick, free floating on acontinuous 0.063-inch thick extruded aluminum retainer. // Design retainer used for flushmounted type to act as a stop for adjacent wall finish material. // Provide appropriatemounting hardware, cushions and base plates as required. Provide factory fabricated endclosure caps at top and bottom <strong>of</strong> surface mounted corner guards.Stainless steel corner guards shall be fabricated <strong>of</strong> 0.0625 inch [1.59 mm] thick stainless steel.Stainless steel corner guards shall be surface mounted, with 3-inch [76-mm] wings and // 1-1/4inch [31.75 mm] radius // ¼-inch [6.35 mm] corner //.A. Resilient and Corrosion Resisting Metal GuardsProvide resilient or corrosion-resisting metal corner guards for the external corners <strong>of</strong> finishedinterior walls and columns in the paths <strong>of</strong> wheeled traffic as indicated below. Use surfaceapplied //full height// //48 inch [1200 mm] high// resilient-type corner guards on gypsumwallboard//, veneer plaster,// //or plaster //walls. Use corrosion-resisting-metal corner guardson masonry or ceramic tile walls. Corner guards are not required in corridors wherecontinuous handrails and bumper guards are used around external corners.Corridors <strong>of</strong>://Operating Suites//Ambulatory Care and Clinical AreasWarehouse and Receiving AreasAreas <strong>of</strong>:Cart StoragePharmacy//Supply Processing and Distribution////Food Preparation and Storage////Service Elevator Lobbies////Rooms containing dumbwaiters or cart-lift elevators//Warehouse and ReceivingB. Structural Steel Angle GuardsProvide structural steel angle guards, protected from corrosion by painting or galvanizing, foruse in corridors and areas <strong>of</strong>:Warehouse and Receiving//Parking Garages and Ambulance Garages//Part I: Basic Solicitation Requirements – Page 168 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Provide structural steel angle guards, protected from corrosion by painting or galvanizing, forexterior use in the paths <strong>of</strong> motor vehicle traffic to the receiving platform (loading dock) and atexposed corners on the platform.7.12 INTERIOR SIGNAGELessor shall develop and submit a signage plan for review and approval by the Contracting<strong>Office</strong>r during design development. Interior signage systems shall include identification,directional, informational, and code required signage. The Lessor shall furnish and installinterior signs for all rooms, areas, conditions or features in the facility. Comply withaccessibility standards listed in Paragraph 4.6 <strong>of</strong> this solicitation. For informational purposes,Offerors are advised that VA has an established signage program, VA Signage Design Guide,which may be found at http://www.cfm.va.gov/til/spclRqmts.asp.7.13 BUILT-IN WORK7.13.1 CASEWORK AND COUNTERTOPSType(s), quantities and locations <strong>of</strong> plastic laminate casework and countertops shall be perSchedule B and as shown on conceptual plans.Special counter tops (wood, stainless steel, chemical resistant laminate, or epoxy) shall beprovided as indicated in Schedule B.A. CaseworkCasework shall be <strong>of</strong> the flush overlay design and, except as otherwise specified, be inconformance with AWI 1600, Modular Cabinets. Fabricate casework <strong>of</strong> plastic laminatedcovered particleboard. Plastic laminate shall conform to NEMA LD-3 Exposed vertical surfaces including both sides <strong>of</strong> cabinet doors shall be high pressurelaminate Type VGS (0.28) Cabinet interiors including shelving shall comply with NEMA, LD3.1 at a minimum:high pressure cabinet liner Type CLS (0.20), OR thermally fused melamine laminate. Backing (concealed surfaces) shall be high pressure backer Type BKH (0.28).Core materials shall be as follows: Particleboard up to 7/8 inch [22.22 mm] thick shall be Industrial Grade average 47-pound density particleboard, ANSI A 208.1, M-3. Particleboard 1 inch [25.4 mm] thick and thicker shall be Industrial Grade average 45-pound density particle-board, ANSI A 208.1, M-2. Moisture Resistant Particleboard shall be average 47-pound density particleboard,ANSI A208.1, M-3. Medium Density Fiberboard 1/4 inch thick shall be average 54-pound density grade,ANSI A208.2.Edging materials shall be 1 mm PVC banding, machine applied, and 3 mm PVC banding,machine applied and machine pr<strong>of</strong>iled to 1/8 inch radius.Part I: Basic Solicitation Requirements – Page 169 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Exposed hardware, except as otherwise specified, shall be satin-finished chromium-platedbrass or nickel plated brass.Hinges shall be fabricated <strong>of</strong> minimum 0.072-inch [1.83-mm] thick chromium-plated steelleaves, with minimum 0.139-inch [3.53-mm] diameter stainless steel pin. Hinges shall be fiveknuckle design with 2-1/2 inch [63.5 mm] high leaves and hospital type tips. Doors 36 inches[914.4 mm] and more in height shall have three hinges, and doors less than 36 inches[914.4 mm] in height shall have two hinges. Each door shall close against two rubberbumpers.Door catches shall be friction or magnetic type, fabricated with metal housing. Provide onecatch for cabinet doors 48 inches [1200 mm] high and under, and two for doors over 48 inches[1200 mm] high.Locks shall be cylinder type, 5 pin tumbler, cam style lock with strike. Acceptable locks for ¾-inch [19 mm] thick doors include: National #M2-3708-157 lock and National #M2-3709-100with strike. Provide two keys for each lock. The name <strong>of</strong> the manufacturer, or trademark bywhich manufacturer can readily be identified, shall be legibly marked on each lock, the keychange number shall be marked on the exposed face <strong>of</strong> lock, and also stamped on each key.Key change numbers shall provide sufficient information for replacement <strong>of</strong> the key by themanufacturer.Drawer and door pulls shall be flush pulls fabricated <strong>of</strong> ABS plastic.Drawer slides shall be full extension, 150-pound [68-kg] load rated epoxy coated steel withnylon, ball bearing rollers, with positive stop both directions.B. CountertopsPlastic Laminate (HPDL) shall conform to NEMA LD 3. Decorative surfaces shall be either: Horizontal: High-pressure decorative laminate type HGS (.048) Post forming: High-pressure decorative laminate type HGP (.039)Concealed backing sheet shall be high-pressure backer BKH (.048) or (.039) to matchexposed faces.Chemical-resistant plastic laminate, NEMA LD3 types HGS or HGP.Test for resistance to reagents as follows: Test with five 0.25 mil drops remaining onsurface for 16 hours followed by washing <strong>of</strong>f with tap water, then cleaned with liquid soap andwater, dried with s<strong>of</strong>t cotton cloth and then cleaned with naphtha. There shall be no change incolor, surface texture, and original protectability remaining from test results <strong>of</strong> followingreagents:98% Acetic Acid Butyl Alcohol Acetone90% Formic Acid Benzine Chlor<strong>of</strong>orm28% Ammonium Hydroxide Xylene Carbon TetrachlorideZinc Chloride (Sat.) Toluene CresolSodium Carbonate (Sat.) Gasoline EtherCalcium Hypochlorite (Sat.) Kerosene Cottonseed OilSodium Chloride (Sat.) Mineral Oil 40% FormaldehydePart I: Basic Solicitation Requirements – Page 170 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Methyl Alcohol Ethyl Acetate TrichlorethyleneEthyl Alcohol Amyl Acetate MonochlorobenzineSuperficial effects only: Slight color change, spot, or residue only with original protectabilityremaining from test results <strong>of</strong> following reagents:77% Sulfuric Acid 37% Hydrochloric Acid 85% Phenol33% Sulfuric Acid 20% Nitric Acid Furfural85% Phosphoric Acid 30% Nitric Acid Dioxane Particleboard up to 7/8 inch [22.22 mm] thick shall be Industrial Grade average 47-pound density particleboard, ANSI A 208.1, M-3. Particleboard 1 inch [25.4 mm] thick and thicker shall be Industrial Grade average 45-pound density particle-board, ANSI A 208.1, M-2.Moisture Resistant Particleboard shall be average 47-pound density particleboard,ANSI A208.1, M-3.Solid Surface Material (SSM): Solid surface material shall be a homogenous filled solidpolymer, not coated, laminated, or <strong>of</strong> a composite construction, and meeting ANSI Z124.3 andANSI Z124.6 requirements.Flammability: Flame Spread shall be 25 max. Smoke Developed shall be 25 max. Materialthickness shall be as indicated on the drawings. Cast, 100 % acrylic solid polymer materialshall be composed <strong>of</strong> acrylic polymer, mineral fillers, and pigments and shall meet thefollowing minimum performance requirements:Property Typical Result TestTensile Strength 6,000 PSI ASTM D 638Tensile Modulus 1.5 x 10 -6 PSI ASTM D 638Tensile Elongation 0.4% min. ASTM D 638Flexural Strength 10,000 PSI ASTM D 790Flexural Modulus 1.2 x 10 -6 PSI ASTM D 790Hardness >85Rockwell "M" ScaleASTM D 785Thermal Expansion3.02 x 10 -5 in./in./°CASTM D 696 (1.80 x 10 -in./in./°F)Gloss (60° Gardner) 5–75 (matte—highly polished) ANSI Z124Light Resistance (Xenon Arc) No effect NEMA LD 3 Method 3.3Wear and Cleanability Passes ANSI Z124.3 & Z124.6Stain Resistance: Sheets Passes ANSI Z124.3 & Z124.6Fungus and BacteriaResistanceDoes not support microbialgrowthASTM G21&G22Part I: Basic Solicitation Requirements – Page 171 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Property Typical Result TestBoiling Water Resistance No visible change NEMA LD 3High Temperature Resistance No change NEMA LD 3Water AbsorptionLong-term0.6% (1⁄2")0.8% (1⁄4")ASTM D 570Molded Resin Tops shall be non-glare epoxy resin or furan resin compounded and cured forminimum physical properties specified. Material shall be <strong>of</strong> uniform mixture throughout.Compressive strength200 MPa (30,000 PSI)Flexural strength70 MPa (10,000 PSI)Rockwell hardness 105Water absorption, 14 hours (weight) .01%Stainless Steel shall conform to ASTM A167, Type 304.Sheet Steel shall conform to ASTM A366, cold rolled, Class 1 finish, stretcher leveled.Hardwood Countertop shall be solid maple, clear grade.Adhesive for plastic laminate shall conform to FS A-A-1936. Adhesive for shop and field jointsin Solid Surface Material (SSM) shall be a two-part adhesive kit to create permanent,inconspicuous, non-porous, hard seams and joints by chemical bond between solid polymermaterials and components to create a monolithic appearance <strong>of</strong> the fabrication. Adhesiveshall be approved by the solid polymer manufacturer. Adhesive shall be color-matched to thesurfaces being bonded where solid-colored, solid polymer materials are being bondedtogether. The seam adhesive shall be clear or color-matched where particulate patterned,solid polymer materials are being bonded together.Fasteners shall be studs, bolts, spaces, threaded rods with nuts, or screws suitable formaterials being joined with metal splice plates, channels, or other supporting shapes.7.13.2 COMPUTER WORKSTATIONS AND KEYBOARD TRAYSComputer keyboard trays shall be provided at each sit down height and standing height kneespace in casework and at each Radiology room control station countertop.7.13.3 LOCKERS AND SHELVINGType(s), quantities, and locations <strong>of</strong> lockers and shelving shall be per Schedule B and asshown on conceptual plans.7.14 PLUMBING FIXTURES, TOILETS AND BATHS7.14.1 TOILETSProvide toilet partitions as indicated on conceptual plans. Room entrance screens that doubleas part <strong>of</strong> a toilet partition enclosure shall be <strong>of</strong> typical stud construction, from floor to ceiling.Part I: Basic Solicitation Requirements – Page 172 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Do not use toilet stalls or divider partitions in single-user toilet rooms in which only a lavatoryand water closet are provided.Conform to Fed. CID A-A-60003, except as modified herein. Fabricate to dimensions shownor specified.Toilet Enclosures shall be Type 1, Style B (Ceiling hung) // C (overhead braced) //. Reinforcepanels to receive toilet tissue holders, grab bars, or other accessories specified. Upper pivotsand lower hinges shall be adjustable to hold doors open 30 degrees. Latching devices andhinges for handicap compartments shall comply with accessibility requirements.Finish: //Baked enamel on steel doors, pilasters, and enclosure panels, except those adjacentto urinals, which shall be stainless steel// //Solid phenolic or solid polyethylene //: waterresistant, graffiti resistant, non-absorbent, contain a minimum 30% post consumer recycledplastic, Class C flame spread rating.//Urinal Screens shall be Type III, Style D (wall hung), //stainless steel// //solid phenolic// //solidpolyethylene//, with integral flanges and continuous, full height wall anchor plate. Screensshall be 24 in' wide x 42 in high [600 mm wide x 1070 mm high].7.14.2 SHOWERSUse ceramic tile applied with thinset Portland cement to concrete-fiber reinforced backer boardfor shower enclosures and partitions <strong>of</strong> contiguous areas. Warp finished floors <strong>of</strong> adjoiningdrying rooms or toilet rooms toward showers to assure drainage to the shower drain. Floorslopes in and around a shower shall not exceed 5%.Construct all patient showers without curbs. In non-patient shower rooms, provide at least oneshower stall without a curb.7.14.3 TOILET AND SHOWER ACCESSORIESTypes and locations <strong>of</strong> toilet accessories shall be as indicated in Schedule B <strong>of</strong> thissolicitation. Multiple units <strong>of</strong> each type <strong>of</strong> accessory shall be furnished by the samemanufacturer. Lessor shall provide suitable backing and other preparation as necessary foritems indicated to be furnished by VA.Toilet accessories shall be shop or factory assembled, free <strong>of</strong> dents and scratches andpackaged complete with anchors and fittings, steel anchor plates, adapters, and anchorcomponents for installation. Grind welded joints smooth. Fabricate units made <strong>of</strong> metal sheet<strong>of</strong> seamless sheets with flat surfaces.Stainless steel sheet shall conform to ASTM A167, Type 304. Stainless steel tubing shallconform to ASTM A269. Galvanized sheet steel shall conform to ASTM A653, G60.Mirror glass shall be float glass, Type I, Class 1, Quality q2 (ASTM C 1036), with silvering,copper coating, and suitable protective organic coating to copper backing in accordance withFS DD-M-411.Adhesive shall be two component epoxy type or contact type and waterpro<strong>of</strong>. Fasteners,screws, and bolts shall be stainless steel or hot dip galvanized. Exposed fasteners shall bePart I: Basic Solicitation Requirements – Page 173 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]tamper-pro<strong>of</strong>. Expansion shields shall be fiber, lead, or rubber as recommended by accessorymanufacturer for component and substrate.Stainless steel shall have No. 4 satin brushed finish, unless otherwise noted. Chrome/NickelPlating shall conform to ASTM B456, Type SC 2, satin finish, unless otherwise noted.Galvanizing for items other than sheet metal shall conform to ASTM A123, 1.25oz/sq yd.7.15 WINDOW TREATMENTSAll exterior windows shall be equipped with window blinds or shades.7.15.1 WINDOW BLINDSBlinds may be aluminum or plastic vertical blinds, or horizontal blinds with aluminum slats <strong>of</strong>one inch width or less. The window blinds must have non-corroding mechanisms andsynthetic tapes.7.15.2 CLOTH WINDOW SHADESProvide opaque cloth shades on windows <strong>of</strong> //radiographic and fluoroscopic rooms, // specialprocedures rooms, //cardiac catheterization rooms, // eye-clinic rooms, // exterior conferencerooms, and rooms containing image intensifiers.7.16 //HOLDING ROOM//Construct walls for holding room from minimum 4-inch [101.6-mm] CMU or 7/8-inch [24.76-mm] PCP (Portland Cement plaster on high-rib lath). Design wall studs for plaster partitionsfor maximum deflection <strong>of</strong> 1/120 <strong>of</strong> the wall height. Studs shall be minimum 4-inch 0.059", 16-gauge. Ceiling shall be 5/8-inch [15.88 mm] GWB.////Construct walls for holding room with 5/8-inch [15.88 mm] abuse-resistant GWB over securitymesh on metal studs as specified for plaster finish. Metal lath or plaster base is unacceptableas security mesh. Security mesh shall be flattened, expanded metal manufactured from highstrength, low alloy steel and shall conform to ASTM F 1267, Type 11, Class 1, Mill finish. Mesh designation: 3/4 #13F Mesh Design Size: 0.923 x 2.10 inch Mesh Opening Size: 0.688 x 1.781 inch 13 meshes per foot, 74% open area Mesh Strand Width: 0.106 inch Mesh Strand Thickness: 0.078 inch Weight: 0.75 pounds per square footProvide manufacturer’s attachment clips and use recommended fasteners to secure mesh towall framing.//The Holding Room should be contiguous with Security Operations Room and contain ashatterpro<strong>of</strong> observation window in the door. The door shall open outward. The holding roomshall not have exterior windows.Part I: Basic Solicitation Requirements – Page 174 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]//Provide one (1) each: motion detector, glass break module, and set <strong>of</strong> door contacts forholding room door. Locate alarm system keypad on the entrance side <strong>of</strong> the holding roomdoor. Connect the alarm system for the holding room to the main building alarm system.Zone the alarm system so that the alarm for the holding room can be set and disarmedindependent <strong>of</strong> the main building alarm system.////Part I: Basic Solicitation Requirements – Page 175 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]SECTION 8 SERVICES, UTILITIES AND MAINTENANCE8.1 UTILITIESThe Lessor shall ensure that public utilities necessary for operation are available and operableat the site at the time <strong>of</strong> final inspection. The Lessor is required to pay any deposits and hookupfees relative to utilities (water-tap fee, water connection fee, sewer connection fee, sewertap fee, etc.).The cost <strong>of</strong> utilities is not included as part <strong>of</strong> the rental consideration. VA will pay allexpenses related to utility usage (electricity, telephone, internet service, cable media,gas, water, and sewage) for space occupied and utilized by VA.//The Lessor shall provide separate meters to measure VA usage versus Lessor usage. Prorationis not permissible. Prior to occupancy by VA, the Lessor shall furnish to the Contracting<strong>Office</strong>r written certification <strong>of</strong> the meter numbers and certification that these numbers measureVA usage only.//8.2 BUILDING MAINTENANCE AND CLEANING BY LESSOR8.2.1 BUILDING MAINTENANCE BY LESSORA. Lessor’s ResponsibilitiesThe Lessor is responsible for total maintenance <strong>of</strong> the leased premises in accordance withParagraph 14 <strong>of</strong> GSA Form 3517B; including special equipment items specified inSchedule B to be maintained by the Lessor. Replacement costs for Schedule B items dueto normal wear and tear are the Lessor’s responsibility. Maintenance <strong>of</strong> special equipmentitems identified in Schedule B to be maintained by VA is excluded from the Lessor’sresponsibility.The Lessor must have a building superintendent or a local, designated representativeavailable to promptly correct deficiencies or attempt to correct deficiencies upon written notice<strong>of</strong> such condition from VA. The Lessor’s superintendent or designated representative shallcorrect or attempt to correct deficiencies within the timeframes specified in the O&M Plan(Paragraph 8.4 below) and agreed to by the Government. If no substantial attempt has beenmade to correct the deficiencies within the specified time, action will be taken by VA to correctsuch deficiencies and the cost <strong>of</strong> repairs will be deducted from the next month's rentalpayment.The Lessor shall provide the labor, material, and supervision to adequately maintain thestructure, the ro<strong>of</strong>, the exterior walls, windows, doors, and any other necessary buildingappurtenances to provide watertight integrity, structural soundness, and acceptableappearance.The Lessor's maintenance responsibility includes initial supplies <strong>of</strong> all items, materials, andequipment necessary for such maintenance. All maintenance work will be done in accordancewith applicable local Building Codes and ordinances, and inspection certificates will bedisplayed as appropriate.Part I: Basic Solicitation Requirements – Page 176 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Maintenance by Lessor includes, but is not limited to, interior and exterior care <strong>of</strong> the buildingand the site; all sidewalks, parking areas, driveways, private access roads, lawns, andshrubbery; utilities; and building service equipment; including all repairs and replacements. Allequipment and systems shall be maintained to provide reliable service without unusualinterruption, disturbing noises, exposure to fire or safety hazards, or unusual emissions <strong>of</strong> dirt.Lessor shall maintain the Essential Electrical System as required by NFPA and JCAHO,including, but not limited to, weekly, monthly, annually, and triennial tests and activities.B. Frequency <strong>of</strong> MaintenanceAt a minimum, the Lessor shall perform the following at the frequency indicated:(1) WeeklyMow and edge lawns weekly during the growth season.(2) MonthlyRemove weeds from around building, parking areas, all landscaped areas (including lawn),and fence borders (both sides <strong>of</strong> fence).Mow and edge lawns at least once a month during the dormant season.Trim and prune shrubbery and trees to maintain an attractive appearance. Shrubbery shallnot be allowed to grow up and cover windows.(3) QuarterlyProvide interior and exterior extermination <strong>of</strong> insects and rodents. Use <strong>of</strong> chemicals shallconform to EPA and State requirements. The Lessor shall provide additional service at therequest <strong>of</strong> VA, if any signs <strong>of</strong> re-infestation appear.Pest management is to be done using an integrated pest management approach thatminimizes the use <strong>of</strong> toxic chemicals.Pesticide shall only be applied by persons deemed qualified by EPA and state requirements.Lessor shall coordinate application <strong>of</strong> pesticide with the Government and only apply pesticidein a manner that VA agrees is protective <strong>of</strong> the health <strong>of</strong> patients, employees, and visitors.(4) Semi-AnnuallyReplace all filters in HVAC system. Replace on a more frequent basis if required by themanufacturer’s recommendations.(5) AnnuallyClean interior <strong>of</strong> all double-walled HVAC units and drain pans. Cleaning shall be done attimes when clinic is not in operation.Re-mulch all planting beds.(6) As RequiredLessor is responsible for the repair and replacement <strong>of</strong> all light fixture ballasts and starters(refer to GSA Form 1217). Lessor shall replace burned out bulbs and fluorescent tubes ininterior light fixtures.Part I: Basic Solicitation Requirements – Page 177 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Lessor is responsible for replacement <strong>of</strong> worn floor or wall coverings (this includes the movingand returning <strong>of</strong> furnishings and equipment), unless caused by negligence on the part <strong>of</strong> VA.Provide interior extermination <strong>of</strong> insects and rodents upon any sign <strong>of</strong> infestation. Use <strong>of</strong>chemicals shall conform to EPA and State requirements.Water the grass and plantings as necessary to maintain their health and attractiveappearance.Fertilize all lawn areas at least three times per year. Fertilizer application prior the start <strong>of</strong> thegrowth season shall contain weed killer per manufacturer’s recommendations.Fertilize plants and trees with type <strong>of</strong> fertilizer recommended by manufacturer. Fertilize withfrequency recommended by manufacturer <strong>of</strong> type <strong>of</strong> fertilizer used.Dead plantings or lawn shall be replaced with like kind immediately. Partially dead plantingsmay be trimmed if, after trimming, a good appearance is maintained.Rake and remove leaves to ensure a good appearance <strong>of</strong> the site.Clean HVAC units inside and out upon any signs <strong>of</strong> mildew or bacterial growth.Pans in HVAC units shall be treated as required to prevent mildew or bacterial growth.//Before working hours //7:30 AM to 5:00 PM// //[______]// remove snow and ice from allentrances, sidewalks parking lots, and approaches. In the event <strong>of</strong> snow or freezing rainduring working hours, removal must occur within one hour from receipt <strong>of</strong> notification by VAstaff. Chemicals or sand may be used to reduce safety hazards.//8.2.2 EXTERIOR CLEANING BY LESSORA. Lessor’s ResponsibilitiesThe Lessor shall maintain the leased premises to provide a clean, neat, and attractiveappearance by performing the functions described below.B. Waste and RecyclingThe Lessor shall have no responsibility for disposing <strong>of</strong> hazardous or pathological waste. TheLessor shall provide collection, disposal, and recycling for all other waste materials generatedby VA. Recycling <strong>of</strong> paper //,[___]// and cardboard is required.Locate waste and recycling containers near the loading dock/service area in accordance withsecurity requirements. The Lessor shall provide and maintain adequate quantity <strong>of</strong> trashcontainer(s), including compacting equipment as required, based on volume <strong>of</strong> waste andfrequency <strong>of</strong> collection. As a minimum, provide //one 8// //two 8// //one 40// //[insert numberand size]// cubic yard covered container with //daily// //weekly// collection and removal fromsite for refuse, trash, and garbage. The Lessor shall provide the covered recyclingreceptacles, and shall collect and remove recycled materials //weekly// //bi-weekly// //[insertfrequency]//.C. ExterminationExtermination <strong>of</strong> insects and rodents shall be provided on a regular basis (minimum <strong>of</strong> everythree (3) months), and upon any sign <strong>of</strong> infestation. Use <strong>of</strong> chemicals shall conform to EPAPart I: Basic Solicitation Requirements – Page 178 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]and state requirements. If any signs <strong>of</strong> re-infestation appear, additional service shall beprovided by the Lessor at the request <strong>of</strong> VA.D. FrequencyAt a minimum, the Lessor shall perform the following at the frequency indicated:(1) DailyBuilding entrances, smoking shelter, and gazebo: Pick up trash, litter, debris, and cigarettebutts.(2) Three Times WeeklySweep landings, steps, and sidewalks.Police all sidewalks, parking areas, green areas, planting beds, driveways, lawns, shrubbery,outside loading dock areas, platforms, etc., to maintain a neat and attractive appearance. Thisshall include, but not be limited to, the removal <strong>of</strong> cigarette butts, debris, litter, trash, limbs, etc.(from both sides <strong>of</strong> fences).(3) QuarterlyLessor shall clean bugs from the interior <strong>of</strong> exterior light lenses.Clean balconies, ledges, courts, areaways, gutters, and flat ro<strong>of</strong>s.//Clean mildew from exterior <strong>of</strong> building, smoking shelter, sidewalks, and ro<strong>of</strong> areas, etc.//(4) Semi-AnnuallyWash outside <strong>of</strong> all exterior windows, glass located over and in exterior and vestibule doors,and all exterior plate glass around entrances, lobbies, vestibules, and skylights.(5) AnnuallyClean exterior <strong>of</strong> building. Remove all spider webs, wasp nests, dirt dobber nests, stains, etc.8.2.3 //INTERIOR CLEANING BY LESSORA. Lessor’s ResponsibilitiesThe Lessor shall furnish all supplies, materials machinery, appliances, supervision, and labornecessary to provide complete janitorial services for the clinic. Services shall be provided inall interior areas <strong>of</strong> the leased premises to provide a clean, neat, and attractive appearance byperforming the functions described below. The Lessor shall make careful selection <strong>of</strong> cleaningproducts and equipment to ensure they are packaged ecologically, environmentally beneficialand/or recycled products that are phosphate-free, non-corrosive, non-flammable, and fullybiodegradable, and minimize the use <strong>of</strong> harsh chemicals and the release <strong>of</strong> irritating fumes.The Lessor shall select paper and paper products with recycled content conforming to EPA’sCPG. Performance will be based on the Contracting <strong>Office</strong>r’s evaluation <strong>of</strong> results, not thefrequency or method <strong>of</strong> performance.Cleaning crew shall turn <strong>of</strong>f lights as necessary and check all doors on completion <strong>of</strong> the workto ensure that doors are locked. Ensure that security alarm is set before leaving if there areno VA personnel on the premises.Part I: Basic Solicitation Requirements – Page 179 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]B. Materials and Procedures(1) StandardsIt is the Lessor's responsibility to maintain the clinic in a condition that meets all housekeepingand sanitation requirements <strong>of</strong> this solicitation and the current standards <strong>of</strong> the JointCommission for the Accreditation <strong>of</strong> Hospitals and Outpatient Clinics (JCAHO).The Lessor shall be responsible for providing a weekly certification in writing to theGovernment that all required cyclic cleaning has been completed.(2) Work ScheduleWork will be accomplished at times indicated. Work schedule shall be from 6:30 AM to11:00 PM, Monday through Friday. The Lessor shall ensure that sufficient employees areavailable to prepare the clinic to see patients at 8:00 AM, to be available to clean up spills,keep the public and specimen collection toilet rooms clean, and keep the toilet rooms stockedwith sufficient paper products and soap. Mechanical equipment such as vacuum cleaners,burnishers, scrubbing machines, etc., will not be used during the hours <strong>of</strong> 7:30 AM to 5:00 PM.(3) Janitorial Staff and SupervisionJanitorial staff will have access throughout the building; therefore, none <strong>of</strong> the janitorial staffmay have a police record for anything more serious than traffic or parking violations.There shall be a janitorial staff supervisor on duty at all times when janitorial staff is in thebuilding. Any person whose work or conduct is found to be unacceptable by the Governmentshall be removed from the janitorial staff.Smoking is permitted in designated areas only. Possession <strong>of</strong> weapons is prohibited.Enclosed containers, including tool kits, shall be subject to search.Janitorial company’s standard uniforms are acceptable, if they clearly identify the companyand the occupation <strong>of</strong> the individual. Janitorial staff will be required to wear photoidentification badges.(4) Safety and Special ProceduresThe Lessor shall consider the clinical environment and ensure that the janitorial staff isinstructed on applicable safety precautions and special requirements. These requirementsmay include, but are not limited to, such conditions as cleaning <strong>of</strong> human secretions, blood,barium, etc., from both floors and walls. Lessor will be notified <strong>of</strong> isolation areas that needterminal cleaning. Terminal cleaning is defined as complete wipe down <strong>of</strong> all sinks, walls,countertops, casework, exam tables, etc., with germicide, and mopping <strong>of</strong> the floor withgermicide. These areas require the use <strong>of</strong> gloves, gowns, masks, and shoe covers, which willbe provided by the Government. The Lessor shall be responsible for collecting <strong>of</strong> sharpscontainers and hazardous materials. See "ALL AREAS" below under "Daily CleaningRequirements" for method <strong>of</strong> handling sharps containers and hazardous waste.The janitorial staff shall comply with applicable Federal, State, and Local safety and fireregulations and codes. The Lessor shall immediately bring to the attention <strong>of</strong> the Governmentany fire and safety deficiencies. The Lessor shall take such safety precautions as necessaryto protect the lives and health <strong>of</strong> occupants <strong>of</strong> the building.(5) Equipment and MaterialsAll equipment and materials used in the performance <strong>of</strong> this contract will be cleaned andstored properly at the end <strong>of</strong> the workday. Cleaning carts and/or equipment will not be leftunattended for any reason while patients are in the clinic. Lessor shall ensure all equipment,Part I: Basic Solicitation Requirements – Page 180 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]tools, and supplies meet necessary safety requirements and janitorial staff have full workingknowledge <strong>of</strong> their use.An EPA-registered germicide will be used to clean all patient areas, floors, examination tables,and medical equipment. The Lessor shall provide all labor, materials, supplies, machinery,and appliances that may be necessary or appropriate in the performance <strong>of</strong> janitorial services.The Lessor shall provide supplies such as toilet tissue, multifold paper towels, toilet seatcovers, and Medicated Vestal hand soap. The Lessor shall provide plastic linings for all trashreceptacles. Provide clear plastic linings for non-hazardous waste trash receptacles and redplastic linings for hazardous waste trash receptacles. Housekeeping aide closets are locatedthroughout the clinic for storage <strong>of</strong> supplies and equipment. The Lessor shall keep a minimum<strong>of</strong> two weeks stock <strong>of</strong> supplies on hand. All accumulated waste shall be removed anddisposed <strong>of</strong> in the dumpster. Hazardous waste and sharps containers shall be picked up andstored in a designated storage area. Supplies to be used shall be approved by theGovernment. Specifications for supplies are as follows:Toilet tissue: Roll type, 4-1/2 inches wide, single plyPaper towels: Multi-fold, 10-1/8 inches wideHand soap: Medicated VestalTrash receptacle liners: (a) Polyethylene, flat type, 33 inches long, 52 inches wide,.66 millimeters thick; (b) Polyethylene, flat type, 24 inches long, 33 inches wide, .31millimeters thick; (c) Polyethylene, red bags (biohazard) 33 inches long, 52 incheswide and 24 inches long, 33 inches wideCarpet shampoo and soil resistant treatment: Non-allergenic typeFurniture polish: Spray type for use on wood and wood veneerWindow cleaner: Ammonia type sufficient to remove smoke film and dustAir freshener cartridges in bathrooms: Johnson Wax Good SenseUpholstery cleaners: Dry or foam type recommended for fabric upholsteryGermicide: EPA-registeredResilient floor tile cleaner and maintainer: As recommended by manufacturer <strong>of</strong>resilient flooringFloor finish: High-speed floor finish as recommended by manufacturer <strong>of</strong> resilientflooringFloor sealer: As recommended by manufacturer <strong>of</strong> resilient flooringFloor stripper: As recommended by manufacturer <strong>of</strong> resilient flooringToilet seat covers: Paper, whitePart I: Basic Solicitation Requirements – Page 181 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]A copy <strong>of</strong> the MSDS sheets for all products used shall be maintained at the clinic and shall beavailable for review by VA upon request.C. Daily Cleaning Requirements(1) Building EntrancesPick up trash and cigarette butts around entrances and vestibules.Empty trash receptacles.(2) Primary Care AreaDuring the hours <strong>of</strong> 6:30 AM to 8:00 AM, Monday through Friday:All primary care area floors shall be wet mopped using a germicide before patients areseen.Wipe down all exam tables with a clean cloth dampened with germicide.Clean and disinfect sinks and countertops.Clean and refill soap dispensers.Clean mirrors.(3) Specialty Care AreaDuring the hours <strong>of</strong> 4:00 PM to 11:00 PMTreatment rooms shall be cleaned and disinfected after each patient procedure.All floors shall be wet mopped using a germicide.Wipe down all exam tables with a clean cloth dampened with germicide.Clean and disinfect sinks, countertops, equipment, etc.Wipe down all walls with a clean cloth dampened with germicide.Clean and refill soap dispensers.Clean mirrors.(4) All AreasDuring the hours <strong>of</strong> 8:00 AM to 4:00 PMTrash receptacles shall be emptied and liners changed.Trash shall be removed from the building and placed in appropriate containers.Boxes and other empty containers, to be disposed <strong>of</strong>, shall be removed from thebuilding and placed in appropriate containers.Hazardous waste and full sharps containers shall be collected in red plastic bags andplaced in cardboard boxes provided.Cardboard boxes shall be sealed with tape and placed in hazardous collection roomfor removal and disposal <strong>of</strong>f site by others.Spills, body fluids, etc. shall be cleaned from floors and walls immediately uponnotification.Remove black scuff marks from corridor floors as necessary.(5) All AreasDuring the hours <strong>of</strong> 4:00 PM to 11:00 PM Complete other required janitorial services. Dust furniture, desks (do not disturb papers on desks), machines, phones, filecabinets, window ledges, etc.Part I: Basic Solicitation Requirements – Page 182 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]All resilient tile floor areas shall be swept and wet mopped with germicide.Electrical equipment shall only be used during these hours.Carpeted areas and mats shall be vacuumed. Carpet sweeper is not acceptable.Spot clean any carpet stains.Spot clean walls and doors.(6) Direct Patient Care AreasDuring the hours <strong>of</strong> 4:00 PM to 11:00 PMJanitorial services in direct patient care areas such as clinics, x-ray, dental, laboratory,rehab medicine, etc.Sweep and wet mop with germicide.Wipe down all exam tables with a clean cloth dampened with germicide.Clean and disinfect sinks and countertops.Clean and refill soap dispensers.Clean mirrors.(7) All RestroomsDuring the hours <strong>of</strong> 8:00 AM to 4:00 PMAll restrooms shall be swept and wet mopped at least twice each day.All paper products and hand soap shall be replenished.All surfaces, including commodes, urinals, walls, mirrors, counters and sinks, shall becleaned and disinfected.Sponges and cloths shall not be used to clean commodes and urinals. Commodes andurinals shall be cleaned with disposable items that are disposed <strong>of</strong> after cleaning commodeand/or urinal in each toilet room. Items used to clean commodes and urinals shall not be usedin turn for cleaning other items or wiping down other surfaces. Clean exterior <strong>of</strong> commodesand urinals first, followed by cleaning <strong>of</strong> the interior.(8) Ceramic Tile Areas (Other than restrooms)During the hours <strong>of</strong> 4:00 PM to 11:00 PMCeramic tile floors shall be swept and damp mopped. If dirt build-up occurs, ceramictile floors shall be scrubbed when determined that it is required by COTR.(9) Corridors, Waiting Areas, Administrative Areas, Mental HealthDuring the hours <strong>of</strong> 4:00 PM to 11:00 PMThe areas shall be swept, wet mopped with a neutral cleaner, and burnished.Carpeted areas shall be vacuumed.(10) Pharmacy, Warehouse, SPD, Biomedical Engineering, Telephone Room, ConferenceRooms (if unoccupied)During the hours <strong>of</strong> 8:00 AM to 4:00 PMThe areas shall be swept, wet mopped with a neutral cleaner, and burnished.Areas with cushioned flooring shall be maintained in accordance with manufacturer'srecommendations.Carpeted areas shall be vacuumed.Part I: Basic Solicitation Requirements – Page 183 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Restrooms shall be swept and wet mopped once each day and all paper products andhand soap replenished.All restroom surfaces, including commodes, urinals, walls, mirrors, counters and sinks,shall be cleaned and disinfected.(11) Shower AreasDuring the hours <strong>of</strong> 4:00 PM to 11:00 PMClean walls and floors with disinfectant.(12) Waiting Room Tables, Doors, Walls and TrimDust tables, ledges, sills, moldings, and baseboards.(13) Mirrors and Glass CleaningClean all mirrors and glass at entrances (fingerprints and smudges).(14) //Screened PorchesSweep daily.//(15) Housekeeping Aide ClosetsClean daily including sinks, floors, and shelves.(16) Isolation RoomsAny room where patients with suspected infectious disease have been examined willbe thoroughly cleaned with germicide (terminal cleaning).(17) Water CoolersClean water coolers.Housing shall be wiped down. Particular attention shall be given to top surface andspout to prevent lime build-up, bacterial growth, etc.(18) Canteen and Vending AreasSpot clean floors, walls, counters, cabinets, sink, microwave, etc. twice daily toeliminate spills, food items, trash, etc.D. Three Times WeeklyCollect, remove, and dispose <strong>of</strong> refuse, trash, and garbage from trash collection area.Apply resilient floor tile cleaner and maintainer to all resilient tile floors and burnish.E. Weekly Cleaning Requirements(1) FurnitureClean as necessary, but no less than weekly. Vacuum upholstered furniture.Part I: Basic Solicitation Requirements – Page 184 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY](2) Carpeted Areas and MatsSpot clean as necessary.(3) All RestroomsScrub floors and ceramic tile base and wipe down with germicide.Clean ceramic tile walls and wipe down with germicide.Spot wash painted walls as necessary.Damp wipe toilet stall partitions and waste receptacles with germicide.(4) Shower AreasScrub ceramic tile floors and walls and wipe down with germicide.Clean grout between tiles in patient and employee showers.(5) Doors, Walls and TrimSpot wash (for fingerprints, smudges, etc.) as necessary but no less than onceweekly.(6) Glass CleaningClean interior and exterior <strong>of</strong> door and entrance glass in waiting areas, laboratories,exam rooms, <strong>of</strong>fices, and treatment rooms.Spot clean walls as necessary, but not less than weekly.F. Monthly Cleaning Requirements(1) FurniturePolish all furniture as necessary, but not less than monthly.(2) Air Conditioning Grilles and RegistersVacuum all grilles and registers.(3) Waiting Areas, Labs, Exam Rooms, <strong>Office</strong>s, Treatment RoomsWash waste receptacles with germicide.(4) Floor Maintenance <strong>of</strong> Resilient Tile AreasApply cleaning soap, as recommended by resilient tile manufacturer, scrub and re-waxhallways, waiting rooms, and lobbies.Apply cleaning soap, as recommended by resilient tile manufacturer, scrub and re-waxother resilient tiled areas as required.G. Quarterly(1) Building InteriorPart I: Basic Solicitation Requirements – Page 185 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Dust window coverings/blinds.Dust handrails and handrail brackets.(2) GroundsTrim/maintain onsite landscaping as required.H. Semi-Annual Cleaning Requirements(1) FurnitureShampoo upholstered furniture during January and July.(2) Carpeted Areas and MatsHave carpets pr<strong>of</strong>essionally steam cleaned and soil resistant treatment applied duringJanuary and July.Spot clean as needed.(3) Floor Maintenance <strong>of</strong> Resilient Tile AreasStrip floors, apply sealer, apply wax and refinish all resilient tile floors.(4) GlassWash inside glass and clean interior <strong>of</strong> all window frames and window stools.(5) Drainage SystemsInspect and clean all onsite catch basins and storm drain inlets <strong>of</strong> trash, leaves, andother deleterious materials.Detention/retention and silting basins shall be inspected and cleaned <strong>of</strong> weeds andovergrowth to ensure proper drainage is maintained.Basin bottoms should be scarified to maintain the integrity <strong>of</strong> the drainage design.8.3 NORMAL HOURSNormal working hours are //7:30 AM to 5:00 PM,// //[______],// except Saturdays, Sundaysand Federal holidays.8.4 BUILDING OPERATING PLANOfferors shall submit a building operating plan with the <strong>of</strong>fer. The plan shall include aschedule <strong>of</strong> startup and shutdown times for operation <strong>of</strong> each building system, such aslighting, cooling, ventilation, and plumbing, necessary for the operation <strong>of</strong> the building. Theplan shall be in operation on the effective date <strong>of</strong> the lease.The Lessor shall submit an Operations and Maintenance Plan narrative as required in PART IISchedule A.Part I: Basic Solicitation Requirements – Page 186 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]8.5 OVERTIME USAGEGovernment shall have access to air-cooled or heated leased space at all times, including theuse <strong>of</strong> elevators, toilets, and lights without additional payment.8.6 FLAG DISPLAYThe Government will be responsible for flag display.8.7 SECURITYThe Government shall provide security personnel to prevent illegal entry or loitering in theleased space and to prevent unauthorized entry during duty hours.The Lessor shall be responsible for providing security to prevent unauthorized entry afternormal working hours.8.8 VA CLEANING RESPONSIBILITY//The Government shall maintain the interior <strong>of</strong> the leased premises in a clean condition. TheGovernment shall provide supplies and equipment.VA shall have no cleaning responsibility for the outside <strong>of</strong> the leased premises.////VA shall have no cleaning responsibility for the interior or exterior <strong>of</strong> the leased premises.The Lessor shall have responsibility for interior janitorial services and shall maintain theinterior <strong>of</strong> the leased premises as described in Paragraph 8.2.3. The Lessor shall provide allcleaning supplies and equipment.//The Government will be responsible for the disposal <strong>of</strong> hazardous or pathological waste whichhas been properly stored in the designated store room. See Paragraph 8.2.3C(4).Part I: Basic Solicitation Requirements – Page 187 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]SECTION 9 SAFETY, FIRE PROTECTION, AND ENVIRONMENTAL MANAGEMENT9.1 GENERAL9.1.1 PERMITSSpace must have a current occupancy permit issued by the local jurisdiction. Lessor shallobtain and maintain in force all necessary permits for operation <strong>of</strong> building services andequipment, including but not limited to fuel-fired mechanical equipment, emergency and standbygenerators, equipment to treat or exhaust toxic or hazardous gases, and solid or liquidwastes.9.1.2 INSPECTIONS BY LESSORLessor shall inspect, test and maintain building systems, fire and life safety systems andequipment, as required by the more stringent <strong>of</strong> NFPA guidelines or local codes. Lessor shallsubmit documentation as acceptable to the Contracting <strong>Office</strong>r <strong>of</strong> tests, report, andmaintenance logs.At a minimum, systems and equipment for which inspections and reports are required include,but are not limited to, those systems as enumerated in NFPA 99, other applicable NFPAguidelines, and the following:Essential Electrical SystemGas and Vacuum SystemsEnvironmental SystemsFire Doors and ShuttersPortable Fire ExtinguishersFire Suppression SystemsStandpipe SystemsFire Detection and Alarm Systems9.1.3 INSPECTIONS BY GOVERNMENTThe government reserves the right to conduct independent inspections, testing, assessments,and detailed studies in space it occupies, as well as in space serving the VA leased space(e.g., common use areas, mechanical rooms, HVAC systems, etc.). The Lessor shall assistVA in its assessments and detailed studies by making available information on buildingoperations and Lessor activities, and providing access to space for assessment and testing, ifrequired. These may include, but are not limited to, noise and vibration testing, water and airquality sampling, water, and air sampling for pathogens, Legionella cultures and copper/silveranalysis, radon testing, mold testing, Facility Condition Assessments <strong>of</strong> building systems andequipment, etc. Work may be performed by independent consultants, or VA personnel.Lessor shall implement corrective measures required by the Contracting <strong>Office</strong>r.9.2 CODE VIOLATIONSEquipment, services, or utilities furnished, and activities <strong>of</strong> other occupants, shall be free <strong>of</strong>safety, health, and fire hazards. When hazards or code violations are detected, they must bePart I: Basic Solicitation Requirements – Page 188 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]promptly corrected at the Lessor's expense. Where requirements conflict, the decision <strong>of</strong> theContracting <strong>Office</strong>r shall be final.9.3 SPECIAL ENVIRONMENTAL REQUIREMENTS9.3.1 INDOOR ENVIRONMENTLessor shall maintain building envelope and building systems in good repair in accordancewith Section 8 and Part II, Appendix A <strong>of</strong> this solicitation. Excess or uncontrolled water candamage interior finishes, furnishings, or equipment, and can contribute to growth <strong>of</strong> mold andother pathogens. Lessor shall take precautions in design, construction, operation, andmaintenance <strong>of</strong> the facility to control the entry <strong>of</strong> water from outside sources or leaks frombuilding systems.Lessor shall promptly repair any leaks and replace damaged materials or finishes. If mold orother pathogens are discovered, Lessor shall be responsible for remediation.9.3.2 SPECIAL BUILDING EQUIPMENTSpecial building equipment required to treat and exhaust to the atmosphere toxic gasesproduced by the agency program equipment shall be maintained in proper operating condition.Maintain all such installations in compliance with appropriate OSHA, EPA, or relatedregulations <strong>of</strong> the local community.Offeror shall obtain operating permits as required by EPA and local Authorities HavingJurisdiction for the operation <strong>of</strong> exhaust-producing generators and building air and waterheating equipment.Part I: Basic Solicitation Requirements – Page 189 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]SECTION 10 INSTRUCTIONS AND PREPARATION10.1 NOTICE TO OFFERORSOfferors must read all parts <strong>of</strong> this Solicitation. All forms required for <strong>of</strong>fer are included in thisSolicitation. Any additional information must be requested in writing. Oral instructions arenot binding.When there is a discrepancy between this Basic Solicitation and GSA forms, the BasicSolicitation will prevail.NOTE: Current GSA forms are available electronically from the GSA web page at thefollowing address:http://www.gsa.gov/Portal/gsa/ep/formsWelcome.do?pageTypeId=8199&channelPage=/ep/channel/gsaOverview.jsp&channelId=-25201.Offerors may utilize these current electronic versions <strong>of</strong> GSA forms to fill in the appropriateinformation in lieu <strong>of</strong> using hardcopy versions provided elsewhere in this Solicitation and fillingin the information by hand.10.2 DEVIATIONSOffers will be construed to be in full and complete compliance with this Solicitation unless theOfferor describes any deviation in the <strong>of</strong>fer. The Contracting <strong>Office</strong>r shall make decisionsregarding deviations that cause the <strong>of</strong>fer to be non-responsive.10.3 ERASURES OR CHANGESThe person signing the <strong>of</strong>fer must initial erasures on, or changes to, the <strong>of</strong>fer forms.NOTE: Agents must submit a valid copy <strong>of</strong> a notarized agreement authorizing him/herto submit <strong>of</strong>fer and negotiate on behalf <strong>of</strong> owner/developer.10.4 COMPLETION OF GSA FORM 3518The Offeror must submit with the <strong>of</strong>fer a signed copy <strong>of</strong> GSA Form 3518, Representations andCertifications, with all information completed as requested.10.5 PREPARATION OF GSA FORM 1217The Offeror must submit a signed copy <strong>of</strong> GSA Form 1217, Lessor's Annual Cost Statement,with the <strong>of</strong>fer. Directions for completion <strong>of</strong> the form are on the back <strong>of</strong> the form.Part I: Basic Solicitation Requirements – Page 190 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]10.6 PREPARATION OF GSA FORM 1364A (REVISED 5/98)The following instructions will assist you in completing GSA Form 1364, Proposal to LeaseSpace. Offers must be submitted in Net Usable Square Feet (NUSF).Section I – Description <strong>of</strong> PremisesBlocks 1 – 7: Enter the general information about the site/building, including address andnumber <strong>of</strong> floors. Enter total amount <strong>of</strong> Net Usable Square Feet <strong>of</strong> space <strong>of</strong>fered. Do notbreak out the space by type. Enter floor load, type <strong>of</strong> construction, and building age. If notapplicable, place N/A in appropriate block(s).Section II – Space Offered and RatesBlocks 8 – 11: Indicate whether space is Full or Partial Floor, enter the number <strong>of</strong> Net UsableSquare Feet <strong>of</strong> space <strong>of</strong>fered. If not applicable, place N/A in appropriate block(s).Enter the Net Usable Square Foot rate per year for the Initial Term, including costs <strong>of</strong> specialrequirements as described in Schedule B and as specified in this Solicitation (refer toParagraph 1.8 PROPOSALS) to be provided by the Lessor.Enter the Net Usable Square Foot rate per year for the Renewal Option including costs <strong>of</strong>special requirements as described in Schedule B and as specified in this Solicitation (refer toParagraph 1.8 PROPOSALS) to be provided by the Lessor. Alternate Proposals may besubmitted on plain bond paper, attached to the form, and signed by the Offeror.Proposals excluding cost <strong>of</strong> special requirements may be submitted on plain bond paper,attached to the form, and signed and dated by the Offeror.Block 11: Determine the Composite Square Foot Rate Per Annum.Block 12: Determine the cost per square foot for operating cost base rate (line 27 <strong>of</strong> the 1217),the cost per square foot for base year taxes (line 28 <strong>of</strong> the 1217), estimated total cost <strong>of</strong>buildout and estimated amortization rate for buildout.Note: Buildout = Total <strong>Construction</strong> Costs.Block 13: Enter the number <strong>of</strong> parking spaces <strong>of</strong>fered (inside and outside) and indicate anycost to the Government, if applicable.Section III – Lease TermsBlocks 14 – 21: Enter information regarding Initial Lease Terms and Renewal Options <strong>of</strong> anyAlternate Proposals, Schedule B lump sum costs, Rentable Square Foot Rate and SquareFootage, Lists <strong>of</strong> Attachments, and any Additional Remarks, List <strong>of</strong> Attachments, Alternates,and any Additional Remarks.Section IV – Owner Identification and CertificationsBlocks 22 – 27: Indicate the Offeror's interest in the <strong>of</strong>fered property. Specify if other thanowner or agent. Agents must submit a valid copy <strong>of</strong> a notarized agreement authorizinghim/her to submit and negotiate on behalf <strong>of</strong> the owner/developer. If the Offeror is apartnership, VA must receive written evidence, by agreement or otherwise, that the personsigning this <strong>of</strong>fer has been authorized to do so by all partners. If the Offeror is a corporation,VA must receive a corporate resolution, signed by the Secretary <strong>of</strong> the corporation underPart I: Basic Solicitation Requirements – Page 191 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]corporate seal that sets forth all <strong>of</strong>ficers <strong>of</strong> the corporation and indicates which are authorizedto bind the corporation.Complete, sign, and date <strong>of</strong>fer.NOTE: OFFER MUST BE RECEIVED BY 4:00 PM (ET) ON THE DATE SPECIFIED INPARAGRAPH 1.5, AT THE ADDRESS CONTAINED IN PARAGRAPH 1.7 OF THISSOLICITATION. ENVELOPE SHOULD BE IDENTIFIED IN THE LOWER LEFTHANDCORNER WITH THE WORDS:"[insert location <strong>of</strong> project] OPC – <strong>SFO</strong> NO. VA-101-XX-RP-XXXX"10.7 DRAWINGS AND SPECIFICATIONS – SUBMISSION WITH OFFEROfferor shall submit drawings and specifications on six discs (CD-Rom as specified inParagraph 1.7.1) and two hard copy sets <strong>of</strong> drawings and specifications with the followingminimum information. Format and for hard copy submittal shall be as follows:(1) DrawingsHard copies shall be black line prints on bond paper, full size (30" x 42"). Each set shallcontain all sheets for all disciplines.(2) SpecificationsHard copies shall be printed on 8½" x 11" bond paper. Materials may be one-sided or doublesided copies. Each copy shall contain all sections. Organize and tab materials by discipline.NOTE 1: Failure to provide drawings and specifications in accordance with the requirementsabove may cause the <strong>of</strong>fer to be deemed unacceptable and rejected accordingly.NOTE2: The conceptual floor diagram provided by VA as a part <strong>of</strong> this Solicitation is intendedto convey desired floor locations and adjacency relationships <strong>of</strong> the main components <strong>of</strong> theprogram. The interior layout and footprint <strong>of</strong> the building may vary as a result <strong>of</strong> actual siteconditions and building design development. The number and location <strong>of</strong> doors will vary asthe Offeror develops detailed plans. The conceptual diagram also shows rooms dedicated tobuilding services. The size and location <strong>of</strong> these rooms will vary as the Offeror developsdetailed plans. It is the Offeror’s responsibility to design the building to comply with applicableBuilding Codes and ordinances. Offerors are advised that rent payment will not be madefor delivered space that is in excess <strong>of</strong> the maximum NUSF solicited.NOTE 3: All drawings shall be prepared per VHA National CAD Standard Application Guide,available on the VA Technical Information Library (TIL) website athttp://www.cfm.va.gov/til/projReq.asp. Drawings shall be on Architectural E-size sheets(30x42 inches). Title blocks shall identify the Offeror and shall include Solicitation Number,Clinic Name, and Location. Drawings shall be organized by discipline and shall include thefollowing minimum information.10.7.2 SITE PLAN(S)Minimum scale 1"=40’ or per local jurisdictions standard requirements, whichever is greater.Plan(s) shall show all site and building demolition, and all site improvements including grading,exterior equipment location, parking, vehicle and pedestrian circulation, storm water retention,Part I: Basic Solicitation Requirements – Page 192 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]and landscaping. Indicate any relationship to flood plains, adjacent uses, and current zoningstatus.Lessor shall identify potential issues as they pertain to the site complying with all Federalstandards when applicable, i.e., National Environmental Policy Act (NEPA), The Department<strong>of</strong> Veterans Affairs Environmental Compliance Manual, Jurisdictional waters <strong>of</strong> the UnitedStates (404 & 401b) individual or nationwide permits, etc.10.7.3 FLOOR PLAN(S)Submit, as a minimum, a double line layout for all floors, penthouses, and ro<strong>of</strong> areas withdouble line exterior walls at a scale not less than 1/8 inch. Show all rooms, doors, corridors,basic column grid, assumed column sizes, expansion and seismic joint locations, mechanical,electrical, and telecommunications rooms, shafts, and (if applicable) all vertical circulation, i.e.,stairs and elevators.Identify each room or space with its space identification code or number from the VAconceptual plan or Room Finish and Door Schedule. Names on drawings shall be the sameas those used in the <strong>SFO</strong>.Show the overall exterior dimensions, dimensions for building wings or <strong>of</strong>fsets, anddimensions for column grids.10.7.4 ELEVATIONSSubmit preliminary elevations <strong>of</strong> all facades showing massing, proposed fenestration, and thebuilding relationship to finish grades. Show all significant building materials, any proposedro<strong>of</strong> top mechanical equipment, and architectural screens on the elevation drawings.Provide a schematic section to define building configuration.10.7.5 COLOR RENDERINGSSubmit a minimum <strong>of</strong> two color renderings <strong>of</strong> perspective views to communicate the designconcept and materials. Submit at least one exterior view illustrating building massing, exteriormaterials and colors, fenestration, and relationship to context. Submit at least one interiorview to illustrate approach to the interior design concept, materials, colors, and integration withwayfinding.Renderings may be prepared using the A/E’s preferred media. Renderings shall be minimum15" x 20". Submit renderings or prints mounted on mat board, foam core, or similar lightweightmaterial. Do not frame renderings.10.7.6 SPECIFICATIONSSubmit outline specifications for foundations, superstructure, exterior closure and buildingenvelope systems, plumbing, fire protection, HVAC, electrical, and telecommunicationssystems.Part I: Basic Solicitation Requirements – Page 193 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]10.8 DESIGN CONCEPT: SUBMISSION WITH OFFEROfferor shall submit design concept materials with other technical submittals on six discs (CDRom as specified in Paragraph 1.7.1) and two hard copy sets <strong>of</strong> drawings and specificationswith the following minimum information. Materials shall be organized and tabbed to follow theoutline in paragraphs 10.8.1 through 10.8.12 below.Hard copies shall be printed on 8½" x 11" bond paper. Materials may be one-sided or doublesidedat Offeror’s option. Bind in one or more volumes as necessary. Identify each volumewith Offeror’s information, solicitation number, clinic name, and location. Each set shallcontain all volumes.10.8.1 ARCHITECTURE/STRUCTURALSubmit a narrative explaining the design concept including exterior design, interior finishes,and interior design concept. Describe overall design concept and relationship to site andcontext. Describe any changes from VA-supplied concept plan for organization <strong>of</strong> spaces,departments, building entrances, and major circulation routes. Discuss preliminary concept forinteriors and finishes.Submit a narrative that clearly explains the engineering criteria and rationale used in selectingthe proposed structural system. Describe proposed materials and approach to be used indesign <strong>of</strong> foundations, vertical members, floor and ro<strong>of</strong> systems, and lateral force resistingsystem. Indicate typical structural bay size.10.8.2 SUSTAINABLE DESIGN AND ENERGY EFFICIENCYSubmit a checklist identifying targeted solutions to meet energy reduction goals and LEED®Silver equivalency. Along with the checklist, the Offeror shall submit a brief statementoutlining how each <strong>of</strong> the LEED® credits proposed will be achieved.10.8.3 FIRE PROTECTIONSubmit a narrative explaining building construction type, building fire/smoke separation, firesprinkler/standpipe systems, water supply available fire flow/maximum demand, and hazardrating and fire alarm systems. Indicate NFPA 220 and IBC fire-resistive ratings <strong>of</strong> the building.10.8.4 MECHANICALSubmit a narrative that clearly states the engineering criteria and rationale used for selectingthe type <strong>of</strong> HVAC system(s) and tentative zoning <strong>of</strong> the systems. State clearly all assumptionsand parameters used in calculating heating and cooling loads. If the calculations areperformed on a computer, provide the name <strong>of</strong> the program. Provide a list <strong>of</strong> the energyconservation measures proposed to be used in the HVAC system design. State clearly thelogic and criteria used in selecting each conservation measure. Investigate the availability <strong>of</strong>utilities, such as natural or propane gas, electricity, etc., for the HVAC equipment and providedescription <strong>of</strong> their status.Provide a single-line schematic plan <strong>of</strong> HVAC zoning.Part I: Basic Solicitation Requirements – Page 194 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]10.8.5 ELECTRICALSubmit a narrative that clearly states the electrical power and lighting design approach,including basic assumptions and information regarding the local electrical utility company.Describe extent <strong>of</strong> utility company work if any is required.10.8.6 STRUCTURED CABLINGSubmit a narrative that clearly states the structured cabling design approach, including basicassumptions and information regarding the data, telephone and CATV/SATV backbone, andhorizontal cabling within the guidelines. Describe the extent <strong>of</strong> outside plant connections,either to service provider connections, or if required, as extensions <strong>of</strong> existing systems.10.8.7 SECURITYSubmit a narrative that clearly states the security intent and cabling design for access control,intrusion detection, and video surveillance, including basic assumptions and informationregarding the topology and connectivity within the guidelines. Describe the extent <strong>of</strong>monitoring, recording, control, and retention <strong>of</strong> all equipment.10.8.8 AUDIO VISUALSubmit a narrative that clearly states the audio visual intent and cabling design for the facility,including basic assumptions and information regarding the topology and connectivity within theguidelines. Describe the extent <strong>of</strong> digital signage, video projection, and sound.10.8.9 SPECIAL SYSTEMSSpecial systems may include but are not limited to the following: Nurse Call Public Address (PA) Intercommunication System Radio Entertainment Distribution (RED) Master Antenna Television (MATV) Radio Paging System Patient Annunciator/Locator System Two-Way Radio System Duress Alarm and Emergency Notification System Security <strong>Management</strong> and Control, and Centralized Police Security <strong>Management</strong>SystemsSubmit a narrative that clearly states the special systems cabling design approach, includingbasic assumptions and information regarding the special systems backbone and horizontalcabling within the guidelines. Describe the extent <strong>of</strong> the special systems and connections fornew installed equipment, or if required, for extension <strong>of</strong> existing systems.10.8.10 PHYSICAL SECURITY MEASURESVA Outpatient facilities must comply with the requirements for Life Safety Protected (LSP) asdefined in VA Physical Security Design Manual (PSDM). Submit a narrative describingphysical security measures incorporated into the design. Include features related to both manmadeand natural events. See Paragraph 4.2.4.Part I: Basic Solicitation Requirements – Page 195 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]10.8.11 WATER DISTRIBUTIONSubmit a narrative that clearly states the water distribution design approach, including basicassumptions and information regarding the local water utility. Describe the required demandincluding the fire flow, the availability to connect to the existing water distributions system,whether the existing system can meet the proposed demand, and the ability to provide alooped system. If the water utility cannot provide modeling information that substantiates thatthe existing system can support the new structure(s), the Lessor shall be responsible forproviding modeling information that supports the new structure(s).10.8.12 SANITARY SEWERAGE SYSTEMSubmit a narrative that discusses the sanitary sewer design approach. Discuss existingcapacity in the downstream sewer system and proposed points <strong>of</strong> connection. Providecalculations substantiating the proposed flows to be generated from this site.10.9 CALCULATIONS: SUBMISSION WITH OFFERThis information will be used to evaluate the "Quality <strong>of</strong> Building and Design Concept" factoras referenced in Paragraph 2.2.Offeror shall submit calculations with other technical submittals on six discs (CD Rom asspecified in Paragraph 1.7.1) and in two hard copy sets. Materials shall be organized andtabbed to follow the outline in Paragraphs 10.9.1 through 10.9.3 below.Hard copies shall be printed on 8½" x 11" bond paper. Materials may be one-sided or doublesidedat Offeror’s option. Bind in one or more volumes as necessary. Identify each volumewith Offeror’s information, solicitation number, clinic name, and location. Each set shallcontain all volumes.10.9.1 AREA COMPUTATIONSSubmit key plans or diagrams to indicate methodology used to compute total gross area <strong>of</strong> thebuilding and the total inside gross area minus the deductions as specified in Paragraph 3.14RENTABLE AND NET USABLE SQUARE FEET <strong>of</strong> this Solicitation to arrive at the total netusable square foot calculation.10.9.2 HVAC CALCULATIONSSubmit preliminary HVAC block load calculations for estimated heating and coolingrequirements <strong>of</strong> the building (BTUH's per gross square foot per year).10.9.3 ELECTRICAL CALCULATIONSSubmit preliminary electrical square foot load calculations for both normal and emergency use.Separate calculations into lighting, receptacles, and equipment power (medical, radiology,//elevator,// and mechanical).Part I: Basic Solicitation Requirements – Page 196 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> No. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]PART IISCHEDULE APart II: Schedule A – Page 1 <strong>of</strong> 10Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> No. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]PART II SCHEDULE A:SECTION 1: OPERATIONS AND MAINTENANCE (O&M) PLAN1.1 MAINTENANCE BY LESSORThis lease will require the Lessor to maintain the building, building equipment and systems,and the exterior premises over the term <strong>of</strong> the lease in accordance with the General Clauses(GSA form 3517B) and Section 8 <strong>of</strong> the Basic <strong>SFO</strong>. The Government requires assurance thatthe building will be kept in good condition with high quality, pr<strong>of</strong>essional management andmaintenance over the full term <strong>of</strong> the lease. Consequently, the proposed O&M Plan for thebuilding will be carefully evaluated.Offerors shall submit O&M Plan with initial <strong>of</strong>fers. The O&M Plan shall describe theorganization and structure the workforce <strong>of</strong> both operations and maintenance personnel.Organization charts; staffing plans indicating trades, number <strong>of</strong> personnel, and experiencelevels; and operating schedules shall be provided for evaluation. In order to assurepr<strong>of</strong>essional management, the Lessor or designated property management firm must have alocal, designated property manager available. The property manager shall have maintenancepersonnel (building superintendent) on site during normal working hours <strong>of</strong> //7:30 AM to 5:00PM// //[___]//, except Saturdays, Sundays, and federal holidays.The O&M Plan shall identify and provide addresses and contact information for entities thatwill maintain the leased premises (designated local property management firm, buildingsuperintendent, and any contractors or subcontractors).The O&M Plan shall outline procedures for dealing with scheduled and non-scheduledmaintenance and repairs.1.2 SCHEDULED MAINTENANCE1.1.1 O&M PLANThe O&M Plan shall indicate how the scheduled (routine) maintenance and repair <strong>of</strong> thebuilding will be managed. For each activity in the O&M plan, the Lessor shall identify theresponsible entity and frequency <strong>of</strong> the maintenance.A. EXTERIOR MAINTENANCEExterior maintenance, including landscaping and grounds, irrigation system, trash removal,exterior lighting, parking lot, pest control, window washing, and general litter pick up shall bediscussed.B. INTERIOR MAINTENANCE:Interior maintenance shall be described, including HVAC, plumbing, electrical, pest control,Schedule B items, and any janitorial maintenance associated with services provided by theLessor.C. QUALITY CONTROL:Describe how the Lessor will provide quality control to ensure that all services described in theO&M Plan are, in fact, provided, and how the Lessor will maintain quality and appearance <strong>of</strong>the entire building over the term <strong>of</strong> the lease.Part II: Schedule A – Page 2 <strong>of</strong> 10Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> No. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]1.3 NON-SCHEDULED MAINTENANCEFor non-scheduled repairs, the O&M Plan shall describe how service calls (emergency androutine) will be addressed. Identify contact information for both normal working hours and for<strong>of</strong>f-hours and holidays. Quantify response times for on and <strong>of</strong>f-site maintenance entities.1.1.1 SERVICE CALLSA. EMERGENCY CALLSService calls will be classified as emergency calls when the condition constitutes animmediate danger to personnel, threatens to damage property, or has a direct impact onoperations or security. Classification <strong>of</strong> calls as emergency shall be at the sole discretion <strong>of</strong>the government. During normal working hours, Lessor’s on-site superintendent shall respondimmediately upon notification. Emergencies occurring at other than normal working hoursshall be responded to (on scene) within 60 minutes <strong>of</strong> receipt <strong>of</strong> call. Lessor shall repair orneutralize the emergency condition before departing the site. If necessary, Lessor shallacquire material by quickest available means and include work outside normal hours. Iffurther labor or materials are required after the emergency is neutralized, the Lessor shallhave the repairs completed within three (3) working days or within such other reasonable timeas agreed to by the government. The Lessor shall have available generally used spare partsand common building materials to support emergency requirements. Lack <strong>of</strong> standardmaterial shall not be a cause for non-performance.B. ROUTINE CALLSService calls will be classified as routine when the condition does not qualify as an emergencycall. Eighty-five (85%) <strong>of</strong> all routine calls shall be completed within five (5) working days afterthe receipt <strong>of</strong> the call, with remainder being completed within ten (10) working days1.4 EXPENSESThe Lessor shall specify in detail, utilizing the Maintenance Cost Worksheet (attached), thoseitems that are included in the O&M Plan for both annual operating and maintenance expenses,and reserves for replacement. The totals <strong>of</strong> these estimated expenses shall be entered on theappropriate lines on GSA Form 1217, Lessor’s Annual Cost Statement.1.5 //FUNDED MAINTENANCE ACCOUNTThe O&M Plan must detail how the Funded Maintenance Account (FMA) will be establishedand how it will be managed. Upon acceptance <strong>of</strong> the facility by the Government, the Lessorshall immediately establish a FMA in trust for VA in an interest-bearing account provided bythe Government and place the equivalent <strong>of</strong> one hundred twenty-five percent (125%) <strong>of</strong> theAnnual Reserve Grand Total (Line 71) from the attached Maintenance Cost Worksheet intothe FMA. At the next quarterly installment and each year thereafter during the lease term,including any renewal options, the amount <strong>of</strong> the annual reserve grand total is to be paid intothe FMA in quarterly increments. The funds are to be made available for all Lessor providedmaintenance services, repairs, and replacements. At the end <strong>of</strong> the VA’s lease term, includingall renewal options, the remaining balance in the FMA account will be released to the Lessor;and the Government will make no claims against the remaining funds.Part II: Schedule A – Page 3 <strong>of</strong> 10Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> No. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]1.6 ADJUSTMENTSAt the beginning <strong>of</strong> the second year and all subsequent years <strong>of</strong> the lease term, including allrenewal options, the operating costs base will be adjusted based on the Consumer Price Index(CPI). Refer also to Paragraph 3.6 <strong>of</strong> the Solicitation For Offers.1.7 SHORT FALLSShortfalls to cover any unforeseen maintenance, repair or replacement expenditure over andabove what is listed in a particular category will be the responsibility <strong>of</strong> the Lessor.1.8 PROPERTY MANAGEMENT AGREEMENTBased upon all the information submitted with the <strong>of</strong>fer, the Government shall require thesuccessful Lessor to execute the “Property <strong>Management</strong> Agreement,” a copy <strong>of</strong> which isattached.//1.9 ATTACHMENTSAttachments:Maintenance Cost Worksheet//Sample <strong>of</strong> the Property <strong>Management</strong> Agreement//Part II: Schedule A – Page 4 <strong>of</strong> 10Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> No. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]MAINTENANCE COST WORKSHEET1. SOLICITATION FOR OFFERS 2. BUILDING NAME AND ADDRESS (No., street, city, state, and zip code)PART I – ANNUAL OPERATING EXPENSES MATERIALS Labor TotalA. Cleaning, Janitor and/or Char Service3. Salaries (Enter on Line 5 GSA form 1217)4. Supplies (wax, cleaners, cloths, etc.) (Enter on Line 6 GSAform 1217)5. Contract Services (window washing, waste and snowremoval) (Enter on Line 7 GSA form 1217)B. Heating System Maintenance and Repair6. Salaries (Enter on Line 8 GSA form 1217)7. Filters, belts, lubricants, fluids, supplies8. Labor (includes contracted work)9. Subtotal Heating System (Add Lines 7 and 8. Enter result here and on Line 10 GSA form 1217)C. Electrical System Maintenance and Repair10. Bulbs, Tubes, Starters (Enter on Line 12 GSA form 1217)11. Ballasts, fixtures, devices, etc.12. Small tools and expendable supplies13. Labor (includes contracted work)14. Subtotal Electrical System (Add Lines 11 to 13. Enter result here and on Line 14 GSA form 1217)D. Plumbing System Maintenance and Repair15. Soap, towels, tissues not in Line 4 above (Enter on Line 16 GSA form 1217)16. Fixtures, pipe and fittings17. Small tools and expendable supplies18. Labor (includes contracted work)19. Subtotal Plumbing System (Add Lines 16 to 18. Enter result here and on Line 17 GSA form 1217)E. Air Conditioning System Maintenance and Repair20. Filters, belts, lubricants, fluids, supplies21. Labor (includes contracted work)22. Subtotal A/C System (Add Lines 20 to 21. Enter result here and on Line 19 GSA form 1217)F. Elevators23. Salaries (operators, starters, etc) (Enter on Line 20 GSA form 1217)24. Small tools and expendable supplies25. Labor (includes contracted work)26. Subtotal Elevators (Add Lines 24 and 25. Enter result here and on Line 21 GSA form 1217)G. Miscellaneous26. Building Engineer/Manager (Enter on Line 22 GSA form 1217)27. Security (Watchmen, Guards) (Enter on Line 23 GSA form 1217)28. Social Security Tax and Workmen’s Compensation Insurance (Enter on Line 24 GSA form1217)29. Landscape and Grounds (materials, fertilizers, supplies)30. L/S and Grounds Labor (includes contracted work)31. Lawn and Landscaping (Add Line 30 and 31. Enter result here and on Line 25 GSA form 1217)32. Other (Explain on separate sheet. Include Schedule B Special Requirement Items) (Enter amounthere and on Line 26 GSA form 1217)33. Subtotal – Annual Operating ExpensesPart II: Schedule A – Page 5 <strong>of</strong> 10Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> No. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]34. SOLICITATION FOR OFFERSMAINTENANCE COST WORKSHEET35. Annual Operating Expenses (from Part I, Line 33 above)ReplacementCOSTUseful Life(Years)A. Exterior and Grounds36. Parking Lot and Road Repair and/or Resurfacing37. Sidewalks38. Landscaping / Lawn Care (Equipment)39. Exterior Painting40. Windows41. Ro<strong>of</strong>B. Building and Equipment42. Doors43. Floor Coverings (other than Carpeting)44. Carpeting45. Interior Painting46. Wall Coverings47. Ceilings48. Blinds / Drapes49. Dock Leveler50. Elevators51. HVAC (include refrigeration equipment and cooling towers)52. Air Handling Equipment53. Exhaust Systems54. Special HVAC Systems55. Plumbing Systems (supply, waste and vent)56. Hot Water Heater57. Fire Protection (fire suppression systems)58. Electrical Systems (distribution and power)59. Generator60. Fire Alarm System61. Communications and Signal Systems62. Security Systems63. Light Fixtures64. Schedule B Special Requirement ItemsC. Other / Miscellaneous (attach additional sheets if necessary)65.66.67.68.69.70. Subtotal Capital Reserve (Add Lines 36 to 69. Enter result here and on Line 30 <strong>of</strong> GSA Form1217)71. Annual Reserve Grand Total (Add Line 35 and 70. Enter result here).ANNUALReservePart II: Schedule A – Page 6 <strong>of</strong> 10Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> No. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]SAMPLE OFPROPERTY MANAGEMENT AGREEMENT (PMA)OUTPATIENT CLINIC[insert location]LEASE NO. VA-101-XX-RP-XXXX1. COMMENCEMENT DATE AND MANAGEMENT FEE:The date <strong>of</strong> commencement for this Property <strong>Management</strong> Agreement (PMA) shall coincidewith the initial term date <strong>of</strong> Lease No. VA-101-XX-RP-XXXX, as determined by the initial leasedocument or subsequent supplemental lease agreement.The Government agrees to pay to the Lessor as part <strong>of</strong> the rental payment a <strong>Management</strong>Fee (as specified on GSA Form 1217, Lessor’s Annual Cost Statement, Line 32). This fee isfor the management <strong>of</strong> all operation expenses, maintenance, repair and reserves forreplacement <strong>of</strong> the leased premises (as specified in Section 1 and Line 30 <strong>of</strong> Section II <strong>of</strong> GSAForm 1217), beginning upon VA occupancy <strong>of</strong> the leased premises. The totals on Lines 27and 30 on GSA Form 1217 shall reflect the annual costs to operate and maintain the leasedpremises. The Government’s payment <strong>of</strong> the <strong>Management</strong> Fee in return for the operationsand maintenance services provided by the Lessor and/or his designated propertymanagement firm shall remain in force for the length <strong>of</strong> the lease term, including all renewaloptions.2. GENERAL MAINTENANCE OBLIGATION:The Lessor is solely responsible for the maintenance and repair <strong>of</strong> the leased premises as wellas any and all Lessor improvements erected on the leased premises, and those items listed inSchedule B (See Paragraph 8.2, Maintenance by Lessor, <strong>of</strong> the Solicitation for exclusions).The Lessor, at its own expense, shall at all times protect, preserve, maintain, and repair theleased premises, together with any and all improvements located thereon (excludingequipment furnished and installed by the Government, sterilizers, and washer/sanitizers), andshall keep the same in good order and condition. The Lessor shall exercise due diligence atall times in the protection <strong>of</strong> the leased premises, together with any and all improvementslocated thereon, against damage or destruction by fire and other causes.3. MAINTENANCE, CAPITAL REPAIR, AND REPLACEMENT:Upon the Government’s acceptance <strong>of</strong> leased premises, the Lessor shall immediatelyestablish a Funded Maintenance Account (FMA) in an interest-bearing account, in a financialinstitution approved by the Government, and begin to make payments into the FMA in suchform and pursuant to such terms as the Government may require.The Lessor’s obligations with respect to the leased premises shall be in effect and enforceableduring the lease term, including all renewal options. The Lessor shall initially place a sumequivalent to one hundred twenty-five percent (125%) <strong>of</strong> the Annual Reserve GrandTotal from the FMA Worksheet into the Funded Maintenance Account. Thereafter, theLessor shall continue to make quarterly payments, at the rate <strong>of</strong> $per quarter, intothe FMA, as defined in Paragraph 4 <strong>of</strong> this Property <strong>Management</strong> Agreement. [The quarterlypayment <strong>of</strong> $is determined by taking the Annual Reserve Grand Totalfrom the FMA WorksheetPart II: Schedule A – Page 7 <strong>of</strong> 10Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> No. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY][(Line 71 in Maintenance Cost Worksheet) ($ ) and dividing that figure by 4].The FMA shall be held in trust for the Government for the sole purpose <strong>of</strong> providing yearlyoperations funding to maintain the leased premises and to pay for capital repairs andreplacements as detailed in this Agreement and as set forth elsewhere in the leaseagreement. The Lessor is required to maintain the funds in the FMA as reflected above andas defined in Paragraph 4 <strong>of</strong> this PMA.a. Building equipment and maintenance requirements, as well as janitorial, groundmaintenance requirements, and pest control (interior and exterior), are to be met bythe Lessor in accordance with the Solicitation, Lease No. VA-101-XX-RP-XXXX, andthe Lessor’s Operations and Maintenance (O&M) Plan as submitted with its <strong>of</strong>fer andattached hereto in this PMA. See Section 8 <strong>of</strong> the Basic Solicitation for furtherdefinition <strong>of</strong> Lessor’s cleaning responsibilities. Such maintenance and repair is toinclude, but not be limited to, cleaning, regular preventative maintenance, testing asrequired, and repair <strong>of</strong>: (1) mechanical, plumbing, electrical, and other buildingservice equipment and systems; (2) ro<strong>of</strong>, foundation and exterior walls, doors andwindows; (3) paved parking areas, drives and roads; (4) landscape and grounds:lawn, shrubbery, trees, irrigation system, and pedestrian walkways; (5) interior andexterior painting; (6) wall, floor and ceiling finishes; (7) sewer and utility lines onproperty; and (8) any other systems deemed property <strong>of</strong> the Lessor or specified to bemaintained by the Lessor.b. The Lessor or designated property management firm must have a local, designatedproperty manager available to promptly correct deficiencies or attempt to correctdeficiencies after oral or written notice <strong>of</strong> such condition from the GovernmentContracting <strong>Office</strong>r (CO) or his/her designated representative(s). The propertymanager shall have a maintenance person on site during normal working hours <strong>of</strong>//7:30 AM to 5:00 PM// //[___]//, except Saturdays, Sundays, and federal holidays toperform preventive maintenance recommended by manufacturer, maintenance andrepair, and to respond to emergencies. The property manager or maintenance personmust respond to emergency calls occurring at other than normal working hours, within60 minutes <strong>of</strong> receipt <strong>of</strong> notification and complete work the same day, if possible.After an emergency condition has been neutralized, emergency repairs requiringadditional labor and/or materials must be completed in no more than 3 days.Responses to emergency and routine maintenance/repair calls during normal workinghours must be made within 30 minutes <strong>of</strong> the occurrence, with 85% <strong>of</strong> all repairscompleted within 5 working days and the remainder within 10 working days. Themaintenance person is responsible for securing additional technical expertise and/oradditional manpower to affect the maintenance or repair, within the time limitsspecified, at the Lessor’s expense. If no substantial attempt has been made to correctthe deficiencies within the specified times above, action will be taken by theGovernment, as specified in Paragraphs 5 and 6 <strong>of</strong> this agreement, to correct suchdeficiencies; and the cost <strong>of</strong> repairs will be deducted from the next month’s rentalpayment. At the VA’s sole discretion, if the maintenance person’s performance isdeemed unacceptable, the Lessor shall immediately replace said person with a newmaintenance person. Determination as to whether or not a call is emergency orroutine shall be at the sole discretion <strong>of</strong> the VA.c. The Lessor’s maintenance responsibility includes initial and replacement supplies <strong>of</strong>all items, materials, and equipment necessary for such maintenance. All maintenancework will be done in accordance with applicable codes, and inspection certificates willbe displayed as appropriate. The Lessor shall provide the labor, material andsupervision to adequately maintain the structure, the utility systems, and the interiorand exterior <strong>of</strong> the building.Part II: Schedule A – Page 8 <strong>of</strong> 10Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> No. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]The Lessor shall provide the labor, material, and supervision necessary to performmanufacturer’s recommended maintenance and to test/inspect those items required to betested/inspected by codes, other publications or VA requirements. The Lessor shallmaintain logs on-site <strong>of</strong> all required inspections, tests, preventive maintenance, etc. Thelogs shall clearly state the item being inspected, tested, or maintained, specific location,description <strong>of</strong> inspection performed, specific code or other reference requiring theinspection, date, and name <strong>of</strong> person performing the work. Copies <strong>of</strong> the logs shall beprovided to the VA on a //monthly// //quarterly// //annual// basis.4. FUNDED MAINTENANCE ACCOUNT (FMA)a. The Lessor shall establish a FMA as set forth in Paragraph 3. The account shall beused to provide maintenance to the lease premises throughout the term <strong>of</strong> the lease,including all renewal options, and to make all necessary capital repairs andreplacements.b. Failure by the Lessor to make the quarterly FMA payments required within Paragraph3 shall constitute an Event <strong>of</strong> Default by the Lessor, as defined in Paragraph 5. Insuch instance, the Government’s remedies shall be those as set forth in Paragraph 6.c. Should the cost <strong>of</strong> any capital repair, replacement, or maintenance be in excess <strong>of</strong> thefunds in any specific category within the FMA, the Lessor shall fund the difference forthat item. The Lessor will not be permitted to use funds in the FMA to pay for out-<strong>of</strong>cyclerepair or replacement <strong>of</strong> any item identified in the FMA without written approvalby VA.d. The Lessor shall submit in writing to the CO or his/her designee a quarterly reportregarding the funding status <strong>of</strong> the FMA. Such report shall begin with theestablishment <strong>of</strong> the FMA, and, thereafter, coincide with the Lessor’s quarterlypayments to the FMA. The report shall include evidence <strong>of</strong> all deposits to andwithdrawals from the FMA and shall identify reasons for each expenditure formaintenance, repair, and replacement made to the clinic building or grounds. TheDepartment <strong>of</strong> Veterans Affairs reserves the right to audit the FMA records at anytime. Such records will be made available to an individual designated by the COwithin seven (7) days <strong>of</strong> written request.e. At the beginning <strong>of</strong> the second year and all subsequent years <strong>of</strong> the lease term,including all renewal options, the Lessor or designated property management firmshall be required to submit an annual operating budget estimate. The budget estimateshall include monthly obligation plan by category, as similarly identified in the originalFMA Worksheet submitted with the Lessor’s <strong>of</strong>fer, for review and approval by VA.The budget estimate and obligation plan will forecast costs <strong>of</strong> all operating expensesfor maintenance, refurbishment, repair, and capital replacement required for theensuing year.f. Shortfalls to cover any unforeseen maintenance expenditure in any specific categorywill be the responsibility <strong>of</strong> the Lessor. No withdrawals from any category beyond theoperating budget obligation plan for that category will be allowed without writtenapproval by VA. At the beginning <strong>of</strong> the second year and all subsequent years <strong>of</strong> thelease term, the Lessor will be allowed to adjust his operating expenses (Line 27 <strong>of</strong>GSA Form 1217 and Part I <strong>of</strong> the FMA Worksheet) to reflect increases in operatingcosts.Part II: Schedule A – Page 9 <strong>of</strong> 10Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> No. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]g. Once the annual budget is approved, VA’s rental rate will be adjusted up or down asnecessary to cover the cost <strong>of</strong> expenses for the ensuing year after accrued interesthas been applied. The submission <strong>of</strong> the annual operating budget estimate andobligation plan shall occur on the anniversary date <strong>of</strong> the acceptance <strong>of</strong> the leasedpremises by the Government.h. At the end <strong>of</strong> VA’s lease term, including all renewal options, the remaining balance inthe FMA account will be released to the Lessor, and the Government will make noclaims against the remaining funds.5. EVENTS OF DEFAULT BY LESSORAn Event <strong>of</strong> Default by the Lessor shall occur upon its failure to perform or observe anycovenant or condition required by Lease No., VA-101-XX-RP-XXXX including all attachmentshereto, and if such failure is not cured to the satisfaction <strong>of</strong> the Government within fifteen (15)days <strong>of</strong> receipt <strong>of</strong> written notice there<strong>of</strong>. Such cure period may, at the sole discretion <strong>of</strong> theGovernment, be extended in writing if such default cannot be reasonably cured within theoriginal fifteen (15) day period and the Lessor is diligently attempting to cure the default. AnEvent <strong>of</strong> Default by the Lessor also shall occur upon the Lessor’s filing <strong>of</strong> a voluntary orinvoluntary petition under any Federal or State bankruptcy law, insolvency law, or similar law.6. REMEDIES FOR DEFAULT BY LESSORUpon the occurrence <strong>of</strong> an Event <strong>of</strong> Default by the Lessor, the Government may exercise anyright, remedy, or privilege, which may be available to it under Lease No. VA-101-XX-RP-XXXXor under applicable Federal, State, or local law. All remedies shall be cumulative and theelection <strong>of</strong> one shall not preclude the exercise <strong>of</strong> another, at the same time or subsequently.Failure to exercise a remedy shall not constitute a waiver there<strong>of</strong>. The Lessor shall remainliable to the extent permitted by law with respect to all covenants and indemnities.Each calendar year during the lease term, including all renewal options, the propertymanagement and maintenance performance <strong>of</strong> the Lessor or designated property managerwill be evaluated. Should the Government, in its sole discretion, find the performance lessthan satisfactory, the Lessor will be notified. Upon receipt <strong>of</strong> such notice, the Lessor shalleither replace the designated property management firm or take immediate action to remedythose areas <strong>of</strong> poor performance to the satisfaction <strong>of</strong> the Government. In the event theLessor performs property management duties directly, the Government’s notice <strong>of</strong> less thansatisfactory performance shall cause the Lessor to designate a pr<strong>of</strong>essional propertymanagement firm to service the leased premises. Such designated firm shall meet theapproval <strong>of</strong> the Government.Attachment: Operations and Maintenance Plan [as submitted with Lessor’s Offer]Part II: Schedule A – Page 10 <strong>of</strong> 10Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]PART IIISCHEDULE B -- SPECIAL REQUIREMENTSPart III: Schedule B – Special Requirements --Page 1 <strong>of</strong> 60Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]PART III: SCHEDULE B--SPECIAL REQUIREMENTSSECTION 1: INSTRUCTIONS FOR PRICING THIS SCHEDULE .......................................................3SECTION 2: GENERAL INFORMATION AND INSTRUCTIONS FOR USERS ..................................4SECTION 3: SPECIAL ITEMS FOR THE ENTIRE CLINIC .................................................................53.1 PUBLIC ADDRESS SYSTEM .............................................................................................. 53.2 AUDIO VISUAL, NURSE CALL, AND CODE ONE (BLUE) SYSTEM ............................. 53.3 MASTER ANTENNA TELEVISION (BROADBAND) SYSTEM ........................................ 53.4 SECURITY MANAGEMENT AND CONTROL, AND CENTRALIZED POLICESECURITY MANAGEMENT SYSTEMS ...................................................................................... 53.5 PATIENT (ALSO STAFF) ANNUNCIATOR/LOCATOR SYSTEM ................................... 53.6 MOTION INTRUSION DETECTOR (MID).......................................................................... 53.7 RADIO ENTERTAINMENT DISTRIBUTION (RED) .......................................................... 63.8 DURESS ALARM AND EMERGENCY NOTIFICATION SYSTEM.................................. 63.9 RADIO PAGING SYSTEM ................................................................................................... 63.10 TWO-WAY RADIO SYSTEM ............................................................................................... 63.11 SECURITY SURVEILLANCE TELEVISION (SSTV) ......................................................... 63.12 INTERCOMMUNICATION SYSTEM .................................................................................. 63.13 VIDEO TELECONFERENCING SYSTEM (VTEL) ............................................................ 63.14 VA SATELLITE TV SYSTEM ............................................................................................... 63.15 ELECTRONIC ACCESS AND DOOR CONTROL SYSTEM ............................................ 7SECTION 4: SPECIAL EQUIPMENT BY FUNCTIONAL AREA .........................................................84.1 FUNCTIONAL AREAS .......................................................................................................... 84.2 .. FUNCTIONAL ROOM LIST ..................................................................................... 9SECTION 5:SUMMARY PRICE SHEETPart III: Schedule B – Special Requirements --Page 2 <strong>of</strong> 60Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]PART III: SCHEDULE B -- SPECIAL REQUIREMENTSSECTION 1: INSTRUCTIONS FOR PRICING THIS SCHEDULEThe Offeror shall submit lump-sum pricing for the purchase and installation <strong>of</strong> specialequipment items specified in Schedule B for laboratory and clinic areas. Offers shall beevaluated in accordance with Part I <strong>of</strong> the Basic Solicitation. All property placed in, upon, orattached to the premises to be leased, and for which the Government pays by means <strong>of</strong> lumpsum,shall be and remain the property <strong>of</strong> the Government, and may be removed or otherwisedisposed <strong>of</strong> by the Government.As part <strong>of</strong> the rental consideration, the Offeror must include supporting construction, HVACsystems, utilities, and electrical distribution systems for Offeror furnished equipment and VAfurnished equipment to be installed in the Outpatient Clinic. The price for each item inSchedule B shall include only the direct costs <strong>of</strong> obtaining and installing the item. Supportingstructure(s) and distribution systems are included in the basic rent. Therefore, no additionalcosts relating to the distribution <strong>of</strong> services (including plumbing, sewage or electricity) orsupporting construction should be ascribed to the special equipment costs in Schedule B.Special equipment items for the clinic are listed in Sections 3 and 4 below. Pricing lines havebeen provided at each item to be included for pricing purposes in the <strong>of</strong>fer. The Offeror isrequired to identify the total price involved for each line item. Totals for each Department orService in the clinic must be entered on the Summary Price Sheet in the Schedule Bdocument.The Schedule B document is available as a convenience to Offerors in the form <strong>of</strong> an Excelworkbook (electronic spreadsheet file). The individual worksheets (spreadsheets) in the filehave been linked and formulas have been provided to facilitate computation <strong>of</strong> extendedprices and totals. Electronic files are provided without warranty or obligation on the part <strong>of</strong> thegovernment as to the accuracy or suitability for use. Users <strong>of</strong> electronic files shall agree toindemnify and hold the VA harmless from any and all claims, damages, losses and expensesincluding, but not limited to, attorney’s fees arising from the use <strong>of</strong> the electronic files.Offerors are responsible for the accuracy and completeness <strong>of</strong> the quantities, costs, subtotals,and totals in their proposals.Items not listed in Schedule B are to be provided by the Lessor as part <strong>of</strong> the rentalconsideration. Such items are either specifically called for in the Basic Solicitation (e.g.,drinking fountains) or identified in a paragraph specifying an allowance for payment under theprovisions <strong>of</strong> the Basic Solicitation (e.g., telecommunications outlets) and are not identified forpricing purposes in Schedule B.Estimated quantities have been provided in Schedule B for use in preparation <strong>of</strong> <strong>of</strong>fers. Anadjustment will be made at the time <strong>of</strong> final inspection on those items specified in Schedule Bif there is any deviation between the quantity actually provided and the Government’sestimated quantity.Part III: Schedule B – Special Requirements --Page 3 <strong>of</strong> 60Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]SECTION 2: GENERAL INFORMATION AND INSTRUCTIONS FOR USERSBrand Names: Certain equipment may be identified by make and model. Identification <strong>of</strong>these items in this Solicitation by a "brand name" description is intended to indicate the qualityand characteristics <strong>of</strong> products that will be satisfactory and is not intended to be restrictive.Unless clearly indicated in the <strong>of</strong>fer that an "equal" product is <strong>of</strong>fered, the <strong>of</strong>fer shall beconsidered as <strong>of</strong>fering a referenced brand name product. Offers <strong>of</strong> "equal" products orequipment will be considered for this award if such product or equipment is clearly identified inthe <strong>of</strong>fer and is determined by the Government to fully meet the salient characteristics <strong>of</strong> theproduct or equipment named in this Solicitation. The Government's determination as to theacceptability <strong>of</strong> the "equal" product shall be based on information furnished or otherwiseidentified in the <strong>of</strong>fer, as well as other information reasonably available to the VA. If theequipment cited in the Solicitation is no longer available, the manufacturer’s currently availableequipment that replaces the cited model shall be provided.Caution to Offerors: The VA is not responsible for locating or securing any information notidentified in the <strong>of</strong>fer and not reasonably available to the VA. Accordingly, the Offeror shallfurnish with its <strong>of</strong>fer the manufacturer and model <strong>of</strong> equipment proposed and sufficientdescriptive material such as cuts, illustrations, drawings, or other information for the VA todetermine whether the product <strong>of</strong>fered meets the specified salient characteristics andestablishes exactly what the Offeror proposes to furnish.Basis <strong>of</strong> Design: Offerors are advised that room layouts and equipment guide lists used inthe development <strong>of</strong> this solicitation were based on VA PG-18-12, Outpatient (SOC/CBOC)Design Guide and VA PG-18-5, Equipment Guide List. These documents are the basis <strong>of</strong>design for VA facilities nationwide and may be found in VA’s Technical Library athttp://www.cfm.va.gov/TIL/ .Part III: Schedule B – Special Requirements --Page 4 <strong>of</strong> 60Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]SECTION 3: SPECIAL ITEMS FOR THE ENTIRE CLINICPlacement <strong>of</strong> special systems required by the entire clinic will be shown ontelecommunications drawings. Please price as totally installed and provide a unit cost for eachitems as listed in this Schedule. Adjustments in the contract at the time <strong>of</strong> approval <strong>of</strong> theequipment drawings will be made based on prices provided by the Offeror in this Schedule Bdocument.Specific Telecommunications Systems (all systems must be approved by the Contracting<strong>Office</strong>r or the Contracting <strong>Office</strong>r's designee.)3.1 PUBLIC ADDRESS SYSTEMProvide a public address system. The system will also allow each area receptionist to addresstheir specific waiting areas. Public address central equipment shall be located in TelephoneEquipment Room. System(s) shall be as manufactured by Bogen, JBL, Dukane, or approvedequivalent, as updated to most current technology or manufacturer.3.2 AUDIO VISUAL, NURSE CALL, AND CODE ONE (BLUE) SYSTEMProvide a complete nurse call system. System(s) shall be as manufactured by Rauland Borg,General Electric, Simplex, or approved equivalent, as updated to most current technology ormanufacturer.3.3 MASTER ANTENNA TELEVISION (BROADBAND) SYSTEMProvide a master antenna television (broadband) system. System(s) shall be as manufacturedby Blonder Tongue, Scientific Atlanta, Olson Technologies, or approved equivalent, asupdated to most current technology or manufacturer.3.4 SECURITY MANAGEMENT AND CONTROL, AND CENTRALIZED POLICESECURITY MANAGEMENT SYSTEMSProvide security management and control, and centralized police security managementsystems. System(s) shall be as manufactured by Lockheed, Viper, Access Gold, Casi-Rusco,or approved equivalent, as updated to most current technology or manufacturer. LAN/WANbased systems must be on a separate and standalone system and NOT connected to theFacility’s LAN/WAN.3.5 PATIENT (ALSO STAFF) ANNUNCIATOR/LOCATOR SYSTEMProvide patient and staff annunciator/locator system. System(s) shall be as manufactured byViking, Radiance, Secur Trak, Patient Central, or approved equivalent, as updated to mostcurrent technology or manufacturer.3.6 MOTION INTRUSION DETECTOR (MID)Provide a motion intrusion detection system. System shall be Security Metrics, Ademco,Honeywell, or approved equivalent, as updated to most current technology or manufacturer.Part III: Schedule B – Special Requirements --Page 5 <strong>of</strong> 60Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]3.7 RADIO ENTERTAINMENT DISTRIBUTION (RED)Provide radio entertainment distribution (RED) systems as required. System(s) shall be asmanufactured by Bogen, JBL, Dukane, or approved equivalent, as updated to most currenttechnology or manufacturer.3.8 DURESS ALARM AND EMERGENCY NOTIFICATION SYSTEMProvide a duress alarm and emergency notification panic system with visual and audibleannunciation at //Security <strong>Office</strong>// //and Central Reception Area//, connected to selectedlocations throughout the facility. System shall be Code Blue Pole Systems or approvedequivalent, as updated to most current technology or manufacturer. Under no circumstanceshall the telephone system be used to provide duress alarm functions.3.9 RADIO PAGING SYSTEMProvide radio paging system (identified as Public Safety Operation and upgraded to LifeSafety when interfaced to Code One (Blue)) as required. System(s) shall be as manufacturedby Motorola, Johnson, Kenwood, or approved equivalent, as updated to most currenttechnology or manufacturer.3.10 TWO-WAY RADIO SYSTEMProvide two-way radio systems as required. System(s) shall be as manufactured by Motorola,Johnson, Vertex Standard, or approved equivalent, as updated to most current technology ormanufacturer.3.11 SECURITY SURVEILLANCE TELEVISION (SSTV)Provide a complete operational SSTV monitoring system with cameras monitoring the buildinginterior, exterior, and parking lot. Provide equipment to monitor each camera. System(s) shallbe as manufactured by Panasonic, Video Tek, Pelco, or approved equivalent, as updated tomost current technology or manufacturer.3.12 INTERCOMMUNICATION SYSTEMProvide an intercommunication system. System(s) shall be as manufactured by Bogen,Aiphone, Leviton, or approved equivalent, as updated to most current technology ormanufacturer.3.13 VIDEO TELECONFERENCING SYSTEM (VTEL)Provide cabling and outlets for the VTEL system. The VA shall provide equipment required forthe VTEL system. Install a CAT 6 cable from a data outlet in designated Treatment,Telemedicine, and Classroom to Telephone Equipment Room. Cable from each room shallterminate in center <strong>of</strong> Telephone Equipment room with thirty (30) feet <strong>of</strong> excess cable andshall be tagged to indicate room that cable serves. System(s) shall be as manufactured byPolycom, Tandberg, HP, or approved equivalent, as updated to most current technology ormanufacturer.3.14 VA SATELLITE TV SYSTEMProvide cabling, outlets, and ro<strong>of</strong> support for VA satellite TV system for reception <strong>of</strong> VAinternal programming. VA shall provide satellite dish for Lessor installation. The VA shallfurnish and install system equipment. Provide coaxial cable, Belden 7731A, from TV outlets inClassroom and Conference Room to Telephone Equipment Room. Cable from each roomPart III: Schedule B – Special Requirements --Page 6 <strong>of</strong> 60Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]shall be installed to center <strong>of</strong> Telephone Equipment Room above ceiling with thirty (30) LF <strong>of</strong>excess cable. Cables shall be tagged to identify room that cable serves. Provide coaxialcable from Telephone Equipment Room to Satellite Dish location on ro<strong>of</strong> (250 LF). Providero<strong>of</strong> support for satellite dish and means <strong>of</strong> anchoring satellite dish to ro<strong>of</strong>. System(s) shall beas manufactured by Scientific Atlanta, Blonder Tongue, Pico Macom, or approved equivalent,as updated to most current technology or manufacturer.3.15 ELECTRONIC ACCESS AND DOOR CONTROL SYSTEMProvide complete, operational electronic card //keypad// access //and door control// system. Allaccess control system products shall be furnished and installed by the same company.System shall be Dyna Lock, Locknetics, Sentrol, or approved equivalent, as updated to mostcurrent technology or manufacturer.Part III: Schedule B – Special Requirements --Page 7 <strong>of</strong> 60Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]SECTION 4: SPECIAL EQUIPMENT BY FUNCTIONAL AREAThis document lists the special equipment required for each room type in each FunctionalArea. Although every room type in the Outpatient Clinic is listed, not every room will havespecial equipment. Where (NR) is indicated, there are no “special requirements” in that room.4.1 FUNCTIONAL AREASAcquisition and Materiel <strong>Management</strong> Services (AMMS)Ambulatory CareAudiology and Speech PathologyCanteenCardiovascular Laboratories-Cardiology ClinicClinic <strong>Management</strong> SuiteDental ServiceEducation <strong>Facilities</strong>EEG LaboratoryEndoscopy Suite-Digestive Diseases ProgramEngineering ServiceEnvironmental <strong>Management</strong> ServiceEye ClinicHealthcare Administration Service (HAS)LobbyLockers, Toilets and ShowersMental Health ClinicPathology and Laboratory MedicinePharmacy ServicePhysical Medicine and Rehabilitation ServicePolice and Security ServiceProsthetics and Sensory Aids ServicePulmonary MedicineRadiology ServiceService OrganizationsSupply, Processing and Distribution (SPD)Surgery ServiceVoluntary ServicePart III: Schedule B – Special Requirements --Page 8 <strong>of</strong> 60Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXPART III: SCHEDULE B--SPECIAL REQUIREMENTS (cont.)4.2--Functional Room ListRoomCodeQty <strong>of</strong>Rooms FunctionDepartment / Functional AreaAcquisition and Materiel <strong>Management</strong> Services (AMMS)SCHEDULE B--SPECIAL REQUIREMENTS: Functional Room ListEquipmentSymbol orJSN Code Item Description Qty Unit Cost Extension Subtotal NotesAMMS MMCR2 NR Holding Area, Unposted Stock No Additional Schedule B ItemsAMMS MMRP1 NR Receiving and Issue Area No Additional Schedule B ItemsAMMS DOCK1 1 Receiving and Shipping Dock $7,258.00A6125 Leveler, Dock 1 $813.00 $813.00K0450 Curtain, Air 1 $2,738.00 $2,738.00S4300 Gun, Steam 1 $3,707.00 $3,707.00AMMS SRHM1 NR Storage, Bio-hazard Waste No Additional Schedule B ItemsAMMS SRE01 NR Storage, Equipment No Additional Schedule B ItemsAMMS SHRM1 NR Storage, Flammable No Additional Schedule B ItemsAMMS SRS01 NR Storage, Form / Processed Stores No Additional Schedule B ItemsAMMS MMGS1 NR Storage, Medical and General No Additional Schedule B ItemsAMMS SRGC1 1 Storage, Medical Gas $6,937.00A5080Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00Cabinet, Base, 4 Drawer,C02D0 36x24x22 1 $1,087.00 $1,087.00C04P0 Cabinet,Sink, 2 Door, 36x36x22 1 $994.00 $994.00Cabinet, Wall, Open, 2 Shelf,CA040 Sloping Top, 38x36x13 1 $646.00 $646.00CS260 Sink, Epoxy Resin, 10x25x15 ID 1 $594.00 $594.00CT060 Countertop, Modified Epoxy Resin 6 $146.00 $876.00CW130 Cabinet, Floor Standing, 5 Shelf, 2Glass Doors, 98x30x22 1 $2,317.00 $2,317.00P1965 Eyewash, Eye/Face, Sink Mounted,Hands Free 1 $356.00 $356.00AMMS SEC01 1 <strong>Office</strong> Secretary and Waiting $30.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00AMMS OFA02 4 <strong>Office</strong> $120.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00AMMS OFA03 1 <strong>Office</strong> $99.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00A3010 Bulletin Board, 48" x 48" 1 $84.00 $84.00Ambulatory CareHealthcare Administration (HAS) CASH1 1 Agent Cashier $0.00A6105 Counter, Reception Control, Built-In Consists <strong>of</strong> two 18” wide basecabinets with two drawers and filedrawer, two 30” wide pencildrawers and two 18” wide basecabinet with four drawers. Plasticlaminate countertop and splash. 1 $0.00Healthcare Administration (HAS) OFA02 8 <strong>Office</strong> $240.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Healthcare Administration (HAS) OFA03 14 Workstation / <strong>Office</strong> $1,386.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00______Lessor Gov't_______Part III: Special Requirements -- Schedule B___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXDepartment / Functional AreaRoomCodeHealthcare Administration (HAS) RECP1 1Qty <strong>of</strong>Rooms FunctionSCHEDULE B--SPECIAL REQUIREMENTS: Functional Room ListEquipmentSymbol orJSN Code Item Description Qty Unit Cost Extension Subtotal NotesF3010 Bulletin Board, 48" x 48" 1 $84.00 $84.00Central Reception Counter andSupplemental <strong>Office</strong> Equipment $2,812.00C0038 Rail, Apron, 4x42x1 1 $116.00 $116.00C0039 Rail, Apron, 4x48x1 1 $84.00 $84.00C0045 Frame, Apron, 1 Drawer, 4x36x22 1 $420.00 $420.00C0046 Frame, Apron, 2 Drawer, 4x48x22 1 $629.00 $629.00C06M0CT030Cabinet, Under Counter, Pull-outBoard, 2 Drawer, 1 File Drawer,30x18x22 1 $863.00 $863.00Countertop, High PressureLaminate 10 $70.00 $700.00Healthcare Administration (HAS) SRE01 NR Supplemental Equipment Space No Additional Schedule B ItemsHealthcare Administration (HAS) TLTU1 2 FU Toilet $2,048.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00Dispenser, Paper Towel, SS,A5080 Surface Mounted 1 $67.00 $67.00A5109 Grab Bars, SS, 1-1/2" Dia AR $175.00 $175.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00A5165 Shelf T-45, SS, 12"w x 5"d 1 $55.00 $55.00A5202P-418Dispenser, Toilet Paper w/UtilityShelf, SS, 2-Roll 1 $74.00 $74.00Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00P-103 Toilet, Wall Hung, w/seat 1 $265.00 $265.00Healthcare Administration (HAS) WRC01 1 FU Waiting Area $436.00Bracket, Television, Wall Mounted,A5210 Adjustable Arm 1 $296.00 $296.00F2310 Rack, Pamphlet, Wall Mounted 1 $140.00 $140.00Healthcare Administration (HAS) WRCH1 NR Workroom No Additional Schedule B ItemsUrgent Care NSTA4 1 Nurse / Communication Station $7,911.00C0045 Frame, Apron, 1 Drawer, 4x36x22 1 $420.00 $420.00C0046 Frame, Apron, 2 Drawer, 4x48x22 1 $629.00 $629.00C06M0C09F0C09G0CG040CG050CT030Cabinet, Under Counter, Pull-outBoard, 2 Drawer, 1 File Drawer,30x18x22 1 $863.00 $863.00Cabinet, Under Counter, 2 Half-Drawer, 2 Door, 30" W 1 $1,175.00 $1,175.00Cabinet, Under Counter, 1 Shelf, 2Door, 30x36x22 1 $930.00 $930.00Cabinet, Wall, 2 Shelf, SlidingGlass Door, Sloping Top,38x36x13 1 $1,291.00 $1,291.00Cabinet, Wall, 2 Shelf, SlidingGlass Door, Sloping Top,38x48x13 1 $1,427.00 $1,427.00Countertop, High PressureLaminate 14 $70.00 $980.00______Lessor Gov't_______Part III: Special Requirements -- Schedule B___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXDepartment / Functional AreaRoomCodeUrgent Care BRIT1 1Urgent Care BRUN1 12Qty <strong>of</strong>Rooms FunctionSCHEDULE B--SPECIAL REQUIREMENTS: Functional Room ListEquipmentSymbol orJSN Code Item Description Qty Unit Cost Extension Subtotal NotesF3050 Whiteboard, Dry Erase 1 $196.00 $196.00Observation / Treatment: InfectiousIsolation Bedroom $6,327.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00A1110 PBPU, Headwall, Prefabricated 1 $5,054.00 $5,054.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5109 Grab Bars, SS, 1-1/2" Dia AR $175.00 $175.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00A5165 Shelf T-45, SS, 12"w x 5"d 1 $55.00 $55.00A5180 Track, Cubicle Curtain, SurfaceMounted 16 $7.00 $112.00F3050 Whiteboard, Dry Erase 1 $196.00 $196.00P-103 Toilet, Wall Hung, w/seat 1 $265.00 $265.00P-418Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00Observation / Treatment: MonitoredBed $81,636.00A1110 PBPU, Headwall, Prefabricated 1 $5,054.00 $5,054.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5180 Track, Cubicle Curtain, SurfaceMounted 16 $7.00 $112.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00A1165 Track, IV, Ceiling Mounted 24 $56.00 $1,344.00F3050 Whiteboard, Dry Erase 1 $196.00 $196.00Urgent Care OFA02 1 <strong>Office</strong>, Head Nurse $30.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Urgent Care OFA03 1 <strong>Office</strong>, Physician $99.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00F3010 Bulletin Board, 48" x 48" 1 $84.00 $84.00Urgent Care SRE01 NR Storage, Medical Equipment No Additional Schedule B ItemsUrgent Care SRLW1 NR Storage, Wheelchair and Stretcher No Additional Schedule B ItemsExam / Treatment Modules (ETM) UCCL1 5 Clean Utility Room $4,730.00Exam / Treatment Modules (ETM) CRA02 5CD040Cabinet, Metal, Wall, T-5B, 2 Shelf,2 Doors, Sloping Top, 36x42x22 1 $946.00 $946.00Multipurpose Conference /Classroom $28,560.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00C0046 Frame, Apron, 2 Drawer, 4x48x22 1 $629.00 $629.00C02C0 Cabinet, Base, 1 Shelf, 1 Drawer, 1Door, 36x24x22 1 $898.00 $898.00C02D0 Cabinet, Base, 4 Drawer,36x24x22 1 $1,087.00 $1,087.00F3050 Whiteboard, Dry Erase 1 $1,960.00 $1,960.00Screen, Projection, RecessedCeiling Mounted, ManualOperation, 69x92 Viewing Area,120" Diagonal 1 $1,108.00 $1,108.00Exam / Treatment Modules (ETM) EXRG3 69 Multipurpose Exam Room $45,885.00______Lessor Gov't_______Part III: Special Requirements -- Schedule B___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]Department / Functional AreaRoomCodeQty <strong>of</strong>Rooms FunctionSCHEDULE B--SPECIAL REQUIREMENTS: Functional Room ListEquipmentSymbol orJSN Code Item Description Qty Unit Cost Extension Subtotal NotesA5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5180 Track, Cubicle Curtain, SurfaceMounted 16 $7.00 $112.00A5165 Shelf T-45, SS, 12"w x 5"d 1 $55.00 $55.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00Lavatory, Vitreous China, withP-418 Sensor Faucet 1 $298.00 $298.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00M1620 Holder, Chart, Patient, Wall orDoor Mounted 1 $28.00 $28.00Exam / Treatment Modules (ETM) TRGM1 2 Multipurpose Procedure Room $5,820.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5180 Track, Cubicle Curtain, SurfaceMounted 12 $7.00 $84.00A5165 Shelf T-45, SS, 12"w x 5"d 1 $55.00 $55.00Lavatory, Vitreous China, withP-418 Sensor Faucet 1 $298.00 $298.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00M1620Holder, Chart, Patient, Wall orDoor Mounted 1 $28.00 $28.00M7405 Light, Exam, Ceiling Mounted 1 $2,348.00 $2,348.00Exam / Treatment Modules (ETM) USCL1 5 Soiled Utility Room $4,470.00Exam / Treatment Modules (ETM) EXRG3 1Exam / Treatment Modules (ETM) SRS01 NRP-418P-505Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00Sink, Service, Clinical Flushing rim,Wall Hung 1 $596.00 $596.00Special Purpose DermatologyExam Room $665.00Storage, Linen, Stretcher and MedicalEquipmentA5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5180 Track, Cubicle Curtain, SurfaceMounted 16 $7.00 $112.00A5165 Shelf T-45, SS, 12"w x 5"d 1 $55.00 $55.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00Lavatory, Vitreous China, withP-418 Sensor Faucet 1 $298.00 $298.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00M1620Holder, Chart, Patient, Wall orDoor Mounted 1 $28.00 $28.00Exam / Treatment Modules (ETM) TLTU1 2 Toilet, Public $2,048.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5109 Grab Bars, SS, 1-1/2" Dia AR $175.00 $175.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00A5165 Shelf T-45, SS, 12"w x 5"d 1 $55.00 $55.00A5202Dispenser, Toilet Paper w/UtilityShelf, SS, 2-Roll 1 $74.00 $74.00______Lessor Gov't_______Part III: Special Requirements -- Schedule BMAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXNo Additional Schedule B Items___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]Department / Functional AreaRoomCodeQty <strong>of</strong>Rooms FunctionSCHEDULE B--SPECIAL REQUIREMENTS: Functional Room ListEquipmentSymbol orJSN Code Item Description Qty Unit Cost Extension Subtotal NotesP-418 Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00P-103 Toilet, Wall Hung, w/seat 1 $265.00 $265.00Exam / Treatment Modules (ETM) WRC01 5 ETM Waiting Area $2,180.00Bracket, Television, Wall Mounted,A5210 Adjustable Arm 1 $296.00 $296.00F2310 Rack, Pamphlet, Wall Mounted 1 $140.00 $140.00Exam / Treatment Modules (ETM) RECP1 5 HAS: Clinic Module Reception Area $14,060.00C0038 Rail, Apron, 4x42x1 1 $116.00 $116.00C0039 Rail, Apron, 4x48x1 1 $84.00 $84.00C0045 Frame, Apron, 1 Drawer, 4x36x22 1 $420.00 $420.00C0046 Frame, Apron, 2 Drawer, 4x48x22 1 $629.00 $629.00C06M0CT030Cabinet, Under Counter, Pull-outBoard, 2 Drawer, 1 File Drawer,30x18x22 1 $863.00 $863.00Countertop, High PressureLaminate 10 $70.00 $700.00Exam / Treatment Modules (ETM) OFA02 35 <strong>Office</strong> $1,050.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Exam / Treatment Modules (ETM) OFA03 5 NS: Cubicle, Resident Physician $495.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00A3010 Bulletin Board, 48" x 48" 1 $84.00 $84.00Exam / Treatment Modules (ETM) MEDP1 2 NS: Medication Room $15,346.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00C04P0 Cabinet,Sink, 2 Door, 36x36x22 1 $994.00 $994.00C02D0 Cabinet, Base, 4 Drawer,36x24x22 1 $1,087.00 $1,087.00CT050 Countertop, SS, w/IntegralBacksplash 6 $531.00 $3,186.00CS090 Sink, SS, Single Compartment,Intergal w/ SS Top, 7.5x19x16 ID 1 $912.00 $912.00Cabinet, Wall, 2 Shelf, SlidingGlass Door, Sloping Top,CG050 38x48x13 1 $1,427.00 $1,427.00Exam / Treatment Modules (ETM) NSTA4 2 Nurse Station (NS) $15,822.00C0045 Frame, Apron, 1 Drawer, 4x36x22 1 $420.00 $420.00C0046 Frame, Apron, 2 Drawer, 4x48x22 1 $629.00 $629.00C06M0C09F0C09G0CG040Cabinet, Under Counter, Pull-outBoard, 2 Drawer, 1 File Drawer,30x18x22 1 $863.00 $863.00Cabinet, Under Counter, 2 Half-Drawer, 2 Door, 30" W 1 $1,175.00 $1,175.00Cabinet, Under Counter, 1 Shelf, 2Door, 30x36x22 1 $930.00 $930.00Cabinet, Wall, 2 Shelf, SlidingGlass Door, Sloping Top,38x36x13 1 $1,291.00 $1,291.00______Lessor Gov't_______Part III: Special Requirements -- Schedule BMAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXX___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXDepartment / Functional AreaRoomCodeQty <strong>of</strong>Rooms FunctionSCHEDULE B--SPECIAL REQUIREMENTS: Functional Room ListEquipmentSymbol orJSN Code Item Description Qty Unit Cost Extension Subtotal NotesCG050Cabinet, Wall, 2 Shelf, SlidingGlass Door, Sloping Top,38x48x13 1 $1,427.00 $1,427.00Countertop, High PressureCT030 Laminate 14 $70.00 $980.00F3050 Whiteboard, Dry Erase 1 $196.00 $196.00Exam / Treatment Modules (ETM) EXRG4 5 NS: Nurse Triage Room $3,185.00Dispenser, Paper Towel, SS,A5080 Surface Mounted 1 $67.00 $67.00Track, Cubicle Curtain, SurfaceA5180 Mounted 12 $7.00 $84.00A5165 Shelf T-45, SS, 12"w x 5"d 1 $55.00 $55.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00Lavatory, Vitreous China, withP-418 Sensor Faucet 1 $298.00 $298.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00M1620Holder, Chart, Patient, Wall orDoor Mounted 1 $28.00 $28.00Exam / Treatment Modules (ETM) OFD03 65 NS: <strong>Office</strong>, Physician / Provider $975.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00Exam / Treatment Modules (ETM) PHDS1 5 NS: Prescription Receiving Station $1,825.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00P-418 Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00Exam / Treatment Modules (ETM) RCA01 NR NS: Storage, Crash Cart No Additional Schedule B ItemsExam / Treatment Modules (ETM) TLTU1 2 NS: Toilet, Staff $2,048.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00Gastroenterology (GI) TRPE1 1A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5109 Grab Bars, SS, 1-1/2" Dia AR $175.00 $175.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00A5165 Shelf T-45, SS, 12"w x 5"d 1 $55.00 $55.00A5202 Dispenser, Toilet Paper w/UtilityShelf, SS, 2-Roll 1 $74.00 $74.00P-418 Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00P-103 Toilet, Wall Hung, w/seat 1 $265.00 $265.00Screening Proctoscopy /Sigmoidoscopy Room $6,277.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00A5180 Track, Cubicle Curtain, SurfaceMounted 12 $7.00 $84.00C03F0 Cabinet, Base, 1 Shelf, 2 Half-Drawer, 2 Door, 36x30x22 2 $1,024.00 $2,048.00C03P0 Cabinet, Sink, 2 Door, 30" W 1 $915.00 $915.00CE030 Cabinet,, Wall, 2 Shelf, GlassDoors, Sloping Top, 38x30x13 2 $789.00 $1,578.00CS090 Sink, SS, Single Compartment,7.5x19x16 ID 1 $912.00 $912.00______Lessor Gov't_______Part III: Special Requirements -- Schedule B___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]Department / Functional AreaRoomCodeQty <strong>of</strong>Rooms FunctionSCHEDULE B--SPECIAL REQUIREMENTS: Functional Room ListEquipmentSymbol orJSN Code Item Description Qty Unit Cost Extension Subtotal NotesCT030M1620Countertop, High PressureLaminate 9 $70.00 $630.00Holder, Chart, Patient, Wall orDoor Mounted 1 $28.00 $28.00Gastroenterology (GI) TLTU1 1 Toilet, Patient $1,024.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00Dermatology (Derm) TRGS1 1A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5109 Grab Bars, SS, 1-1/2" Dia AR $175.00 $175.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00A5165 Shelf T-45, SS, 12"w x 5"d 1 $55.00 $55.00A5202 Dispenser, Toilet Paper w/UtilityShelf, SS, 2-Roll 1 $74.00 $74.00P-418 Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00P-103 Toilet, Wall Hung, w/seat 1 $265.00 $265.00Dermatology Procedure /Treatment Room $562.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5180 Track, Cubicle Curtain, SurfaceMounted 12 $7.00 $84.00A5165 Shelf T-45, SS, 12"w x 5"d 1 $55.00 $55.00P-418Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00M1620 Holder, Chart, Patient, Wall orDoor Mounted 1 $28.00 $28.00Dermatology (Derm) LBDE1 1 Dermatology Laboratory $4,098.00A5080Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00Dermatology (Derm) MEDP1 1C0045 Frame, Apron, 1 Drawer, 4x36x22 1 $420.00 $420.00C01C0 Cabinet, Base, 1 Shelf, 1 Drawer, 1Door, 36x18x22 1 $890.00 $890.00C01D0 Cabinet, Base, 4 Drawer,36x18x22 1 $780.00 $780.00C02Q0 Cabinet, Sink, 1 Door, 36x24x22 1 $650.00 $650.00CG040Cabinet, Wall, 2 Shelf, SlidingGlass Door, Sloping Top,38x36x13 1 $1,291.00 $1,291.00Dermatology Medication Prep /Storage Room $4,951.00C04P0 Cabinet,Sink, 2 Door, 36x36x22 1 $994.00 $994.00C02D0CT050CS090Cabinet, Base, 4 Drawer,36x24x22 1 $1,087.00 $1,087.00Countertop, SS, w/IntegralBacksplash 1 $531.00 $531.00Sink, SS, Single Compartment,Intergal w/ SS Top, 7.5x19x16 ID 1 $912.00 $912.00______Lessor Gov't_______Part III: Special Requirements -- Schedule BMAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXX___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]Department / Functional AreaRoomCodeDermatology (Derm) OPDU1 1Qty <strong>of</strong>Rooms FunctionSCHEDULE B--SPECIAL REQUIREMENTS: Functional Room ListEquipmentSymbol orJSN Code Item Description Qty Unit Cost Extension Subtotal NotesCG050Cabinet, Wall, 2 Shelf, SlidingGlass Door, Sloping Top,38x48x13 1 $1,427.00 $1,427.00Dermatology PhototherapyTreatment Room $6,277.00A5080Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00Dermatology (Derm) SHWR1 1A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00A5180 Track, Cubicle Curtain, SurfaceMounted 12 $7.00 $84.00C03F0 Cabinet, Base, 1 Shelf, 2 Half-Drawer, 2 Door, 36x30x22 2 $1,024.00 $2,048.00C03P0 Cabinet, Sink, 2 Door, 30" W 1 $915.00 $915.00CE030 Cabinet,, Wall, 2 Shelf, GlassDoors, Sloping Top, 38x30x13 2 $789.00 $1,578.00CS090 Sink, SS, Single Compartment,7.5x19x16 ID 1 $912.00 $912.00CT030 Countertop, High PressureLaminate 9 $70.00 $630.00M1620 Holder, Chart, Patient, Wall orDoor Mounted 1 $28.00 $28.00Dermatology Phototherapy ShowerRoom $848.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5109 Grab Bars, SS, 1-1/2" Dia AR $175.00 $175.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00A5180 Track, Cubicle Curtain, SurfaceMounted 4 $7.00 $28.00P-418 Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00Seat, Folding, Accessible Shower 1 $175.00 $175.00Nutrition (Dietetics) CLR02 1 Classroom $2,531.00F3050 Whiteboard, w/ Sliding Panels 1 $1,423.00 $1,423.00M0410Screen, Projection, RecessedCeiling Mounted, ManualOperation, 69x92 Viewing Area,120" Diagonal 1 $1,108.00 $1,108.00Nutrition (Dietetics) OFA02 3 <strong>Office</strong>, Dietician $90.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Oncology (ONC) OPCT1 1 Chemotherapy Treatment Room $27,494.00A1107 Rail System, Utility, Med Gas 3 $7,421.00 $22,263.00A5145 Coat Hook, SS, Surface Mounted 3 $15.00 $45.00Track, Cubicle Curtain, SurfaceA5180 Mounted 18 $7.00 $126.00F2310 Rack, Pamphlet, Wall Mounted 1 $140.00 $140.00A5210 Bracket, Television, Wall Mounted,Adjustable Arm 3 $296.00 $888.00A1165 Track, IV, Ceiling Mounted 72 $56.00 $4,032.00Oncology (ONC) TLTU1 1 Toilet, Patient $1,024.00______Lessor Gov't_______Part III: Special Requirements -- Schedule BMAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXX___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]Department / Functional AreaRoomCodeOncology (ONC) OFA02 1Qty <strong>of</strong>Rooms FunctionSCHEDULE B--SPECIAL REQUIREMENTS: Functional Room ListEquipmentSymbol orJSN Code Item Description Qty Unit Cost Extension Subtotal NotesA1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5109 Grab Bars, SS, 1-1/2" Dia AR $175.00 $175.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00A5165 Shelf T-45, SS, 12"w x 5"d 1 $55.00 $55.00A5202 Dispenser, Toilet Paper w/UtilityShelf, SS, 2-Roll 1 $74.00 $74.00P-418 Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00P-103 Toilet, Wall Hung, w/seat 1 $265.00 $265.00<strong>Office</strong>, Data Coordination / TumorRegistry $30.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Oncology (ONC) LBVP1 1 Oncology Lab $2,050.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00P2450 Valve, Mixing Thermostatic 1 $2,035.00 $2,035.00Women's Health / GYN EXRG8 1 Exam Room $665.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5180 Track, Cubicle Curtain, SurfaceMounted 16 $7.00 $112.00A5165 Shelf T-45, SS, 12"w x 5"d 1 $55.00 $55.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00Lavatory, Vitreous China, withP-418 Sensor Faucet 1 $298.00 $298.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00M1620Holder, Chart, Patient, Wall orDoor Mounted 1 $28.00 $28.00Womens's Health / GYN TLTU1 1 Toilet, Patient $1,024.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5109 Grab Bars, SS, 1-1/2" Dia AR $175.00 $175.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00A5165 Shelf T-45, SS, 12"w x 5"d 1 $55.00 $55.00A5202 Dispenser, Toilet Paper w/UtilityShelf, SS, 2-Roll 1 $74.00 $74.00P-418 Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00P-103 Toilet, Wall Hung, w/seat 1 $265.00 $265.00Orthopedics (Ortho) OPCR1 1 Cast Room $10,857.00A1107 Rail System, Utility, Med Gas 1 $7,421.00 $7,421.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5180 Track, Cubicle Curtain, SurfaceMounted 14 $7.00 $98.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00P-418 Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00P-507 Sink, SS, Single Compartment,12x22x16 ID, w/ IntegralDrainboard (w/out corrugations) 1 $2,250.00 $2,250.00______Lessor Gov't_______Part III: Special Requirements -- Schedule BMAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXX___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]Department / Functional AreaRoomCodeQty <strong>of</strong>Rooms FunctionSCHEDULE B--SPECIAL REQUIREMENTS: Functional Room ListEquipmentSymbol orJSN Code Item Description Qty Unit Cost Extension Subtotal NotesP7650 Trap, Plaster, Small 1 $405.00 $405.00C0052 Pegboard, Heavy Duty, w/Hangers, 48x96 1 $275.00 $275.00M1620 Holder, Chart, Patient, Wall orDoor Mounted 1 $28.00 $28.00Orthopedics (Ortho) DR001 2 Dressing Room, Patient $672.00A1066 Mirror, SS Framed, 20x48 1 $95.00 $95.00A5021 Bench, Dressing, Wall Mounted 1 $211.00 $211.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Orthopedics (Ortho) ORPC1 1 Storage, Plaster and Splints $825.00C0052Pegboard, Heavy Duty, w/Hangers, 48x96 3 $275.00 $825.00Clinic Based <strong>Home</strong> Care (CBHC) OFA02 5 <strong>Office</strong> $150.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Clinic Based <strong>Home</strong> Care (CBHC) OFD03 3 <strong>Office</strong> $297.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00A3010 Bulletin Board, 48" x 48" 1 $84.00 $84.00Clinic Based <strong>Home</strong> Care (CBHC) OFA01 1 <strong>Office</strong> $30.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Patient Education (Pat EDU) LIBV1 1 Information Resource Center $2,531.00F3055 Whiteboard, w/ Sliding Panels 1 $1,423.00 $1,423.00M0410Screen, Projection, RecessedCeiling Mounted, ManualOperation, 69x92 Viewing Area,120" Diagonal 1 $1,108.00 $1,108.00Patient Education (Pat EDU) CLR01 1 Classroom $2,531.00F3055 Whiteboard, w/ Sliding Panels 1 $1,423.00 $1,423.00M0410Screen, Projection, RecessedCeiling Mounted, ManualOperation, 69x92 Viewing Area,120" Diagonal 1 $1,108.00 $1,108.00Audiology and Speech PathologyAudiology (AUD) PEHS1 1 Booth, Audometric Exam $19,736.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00M0050M1620Booth, Audio, Double Wall,Definitive teat, 1 Person 1 $19,693.00 $19,693.00Holder, Chart, Patient, Wall orDoor Mounted 1 $28.00 $28.00Audiology (AUD) EXEN1 1 Electrophysiology Room $483.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00M1620 Holder, Chart, Patient, Wall orDoor Mounted 1 $28.00 $28.00P-418 Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00Audiology (AUD) OPMH1 1 Group Therapy Room $400.00A5120 Window, Observation, One-Way 1 $400.00 $400.00Audiology (AUD) HAFR1 1Hearing Aid Fabrication /Modification Room $440.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00______Lessor Gov't_______Part III: Special Requirements -- Schedule BMAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXX___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXDepartment / Functional AreaRoomCodeQty <strong>of</strong>Rooms FunctionSCHEDULE B--SPECIAL REQUIREMENTS: Functional Room ListEquipmentSymbol orJSN Code Item Description Qty Unit Cost Extension Subtotal NotesA5080P-418Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00Audiology (AUD) TREN1 1 Immittance Room $55,890.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00M0041 Booth, Audio, Double Wall, Suite 1 $55,847.00 $55,847.00Audiology (AUD) SRCH1 NRM1620Holder, Chart, Patient, Wall orDoor Mounted 1 $28.00 $28.00Instrument Calibrationand StorageRoom 1No Additional Schedule B ItemsAudiology (AUD) EXOS1 1 <strong>Office</strong>, Therapy Room, Audiologist $15.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00Audiology (AUD) EXEN1 1 Posturography Room $483.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00M1620 Holder, Chart, Patient, Wall orDoor Mounted 1 $28.00 $28.00P-418 Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00Audiology (AUD) PESH4 1 Suite, Audiometric Exam $55,890.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00M0041 Booth, Audio, Double Wall, Suite 1 $55,847.00 $55,847.00M1620 Holder, Chart, Patient, Wall orDoor Mounted 1 $28.00 $28.00Audiology (AUD) EXVE1 1 Vestibulography Room $365.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00P-418 Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00Audiology (AUD) SRSE1 NR Equipment Area 1 No Additional Schedule B ItemsAudiology and Speech Pathology OFA03 1 <strong>Office</strong>, Administrative Assistant $99.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00F3010 Bulletin Board, 48" x 48" 1 $84.00 $84.00Audiology and Speech Pathology OFA02 1 <strong>Office</strong>, Chief <strong>of</strong> Service $15.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00Audiology and Speech Pathology RECP1 1 <strong>Office</strong>, Reception / Control Clerk $2,812.00C0038 Rail, Apron, 4x42x1 1 $116.00 $116.00C0039 Rail, Apron, 4x48x1 1 $84.00 $84.00C0045 Frame, Apron, 1 Drawer, 4x36x22 1 $420.00 $420.00C0046 Frame, Apron, 2 Drawer, 4x48x22 1 $629.00 $629.00C06M0CT030Cabinet, Under Counter, Pull-outBoard, 2 Drawer, 1 File Drawer,30x18x22 1 $863.00 $863.00Countertop, High PressureLaminate 10 $70.00 $700.00Audiology and Speech Pathology SEC01 1 <strong>Office</strong>, Secretary / Clerks $30.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00______Lessor Gov't_______Part III: Special Requirements -- Schedule B___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXDepartment / Functional AreaRoomCodeQty <strong>of</strong>Rooms FunctionSCHEDULE B--SPECIAL REQUIREMENTS: Functional Room ListEquipmentSymbol orJSN Code Item Description Qty Unit Cost Extension Subtotal NotesAudiology and Speech Pathology TLTU1 1 Toilet, Patient $1,024.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5109 Grab Bars, SS, 1-1/2" Dia AR $175.00 $175.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00A5165 Shelf T-45, SS, 12"w x 5"d 1 $55.00 $55.00A5202 Dispenser, Toilet Paper w/UtilityShelf, SS, 2-Roll 1 $74.00 $74.00P-418 Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00P-103 Toilet, Wall Hung, w/seat 1 $265.00 $265.00Audiology and Speech Pathology WRC01 1 Waiting Area $436.00Speech Pathology (SP) EXOS1 1Speech Pathology (SP) WRCH1 NRBracket, Television, Wall Mounted,A5210 Adjustable Arm 1 $296.00 $296.00F2310 Rack, Pamphlet, Wall Mounted 1 $140.00 $140.00<strong>Office</strong>, Therapy Room, SpeechPathologist $15.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00Computer Assisted Training (CAT)WorkroomSpeech Pathology (SP) OPMH1 1 Group Therapy Room $400.00A5120 Window, Observation, One-Way 1 $400.00 $400.00Speech Pathology (SP) EXOS1 1 Speech Analysis Laboratory $15.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00CanteenNo Additional Schedule B ItemsCanteen Service FSDC1 NR Canteen No Additional Schedule B ItemsCanteen Service SL001 1 Staff Lunch / Break Room $6,681.00A1080 Mirror, Posture, Wall Mounted 1 $338.00 $338.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00A5210 Bracket, Television, Wall Mounted,Adjustable Arm 1 $296.00 $296.00C02C0 Cabinet, Base, 1 Shelf, 1 Drawer, 1Door, 36x24x22 1 $898.00 $898.00C02D0 Cabinet, Base, 4 Drawer,36x24x22 1 $1,087.00 $1,087.00C04P0 Cabinet,Sink, 2 Door, 36x36x22 1 $994.00 $994.00CB020 Cabinet, Wall, 2 Shelf, 1 Door,Sloping Top, 38x24x13 2 $669.00 $1,338.00CS010 Sink, SS, Single Compartment,7.5x12x12 ID 1 $768.00 $768.00CT030 Countertop, High PressureLaminate 9 $70.00 $630.00F3025 Board, Bulletin, Wood Framed 1 $54.00 $54.00F3050 Whiteboard, Dry Erase 1 $196.00 $196.00Canteen Service BX001 NR Vending Machine Area and Seating 1 No Additional Schedule B ItemsCardiovascular Laboratories (Cardiology)Cardiology OPEC1 1 ECG Testing Cubicle $70.00A5180Track, Cubicle Curtain, SurfaceMounted 10 $7.00 $70.00______Lessor Gov't_______Part III: Special Requirements -- Schedule B___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXDepartment / Functional AreaRoomCodeQty <strong>of</strong>Rooms FunctionSCHEDULE B--SPECIAL REQUIREMENTS: Functional Room ListEquipmentSymbol orJSN Code Item Description Qty Unit Cost Extension Subtotal NotesCardiology OPPE1 1 Echocardiography Exam Room $553.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00Cardiology OPTM1 1A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00A5180 Track, Cubicle Curtain, SurfaceMounted 10 $7.00 $70.00M1620 Holder, Chart, Patient, Wall orDoor Mounted 1 $28.00 $28.00P-418 Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00Exercise Room (Stress LabFacility) $553.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00A5180 Track, Cubicle Curtain, SurfaceMounted 10 $7.00 $70.00M1620 Holder, Chart, Patient, Wall orDoor Mounted 1 $28.00 $28.00P-418 Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00Cardiology OPHM1 1 Pacemaker / Holter Monitor Room $540.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00A5180 Track, Cubicle Curtain, SurfaceMounted 10 $7.00 $70.00P-418 Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00Clinic <strong>Management</strong>Clinic <strong>Management</strong> CRA01 1 Conference Room $4,576.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00F3030 Board, Scheduling, Magnetic 1 $286.00 $286.00F3045 Whiteboard / Projection Screen,Cabinet 1 $1,627.00 $1,627.00F3055 Whiteboard, w/ Sliding Panels 1 $1,423.00 $1,423.00F3230 Rack, Hat / Coat, Wall Mounted 1 $102.00 $102.00M0410Screen, Projection, RecessedCeiling Mounted, ManualOperation, 69x92 Viewing Area,120" Diagonal 1 $1,108.00 $1,108.00Clinic <strong>Management</strong> OFC01 1 <strong>Office</strong> $107.00A5155 Costumer, Wall, Executive 1 $107.00 $107.00Clinic <strong>Management</strong> OFA02 4 <strong>Office</strong> $120.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Clinic <strong>Management</strong> SEC01 3 <strong>Office</strong>, Secretary and Waiting $90.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Clinic <strong>Management</strong> SRSE1 NR Support Equipment No Additional Schedule B Items______Lessor Gov't_______Part III: Special Requirements -- Schedule B___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]Department / Functional AreaRoomCodeQty <strong>of</strong>Rooms FunctionSCHEDULE B--SPECIAL REQUIREMENTS: Functional Room ListEquipmentSymbol orJSN Code Item Description Qty Unit Cost Extension Subtotal NotesClinic <strong>Management</strong> TLTU1 1 Toilet, Staff $1,024.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5109 Grab Bars, SS, 1-1/2" Dia AR $175.00 $175.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00A5165 Shelf T-45, SS, 12"w x 5"d 1 $55.00 $55.00A5202 Dispenser, Toilet Paper w/UtilityShelf, SS, 2-Roll 1 $74.00 $74.00P-418 Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00P-103 Toilet, Wall Hung, w/seat 1 $265.00 $265.00DentalDental DNTG2 10Combined Dental HygieneOperatory $80,810.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00Dispenser, Paper Towel, SS,A5080 Surface Mounted 1 $67.00 $67.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00D0792 Sink, SS, without faucet, 8x14x10 1 $481.00 $481.00D0811 Valve, Water, Foot with faucet 1 $421.00 $421.00D9250 Rail, Apron 4.5"Hx2"D 5 $92.00 $460.00Cabinet, Wall Hung, 2 SlidingD9420 Doors, 30x36x12 2 $1,079.00 $2,158.00D9520 Cabinet, Base, 5 Drawer 2 $920.00 $1,840.00D9540 Cabinet, Base, 1-2 Door, 37x20x19 1 $668.00 $668.00D9610 Cabinet, Base, with Sink, 2 Doors 1 $1,257.00 $1,257.00D9941Countertop, Laminated, 3/4-inchThick 16 $39.00 $624.00Dental CRA01 1 Conference Room $4,576.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00F3030 Board, Scheduling, Magnetic 1 $286.00 $286.00F3045 Whiteboard / Projection Screen,Cabinet 1 $1,627.00 $1,627.00F3055 Whiteboard, w/ Sliding Panels 1 $1,423.00 $1,423.00F3230 Rack, Hat / Coat, Wall Mounted 1 $102.00 $102.00M0410 Screen, Projection, RecessedCeiling Mounted, ManualOperation, 69x92 Viewing Area,120" Diagonal 1 $1,108.00 $1,108.00Dental DNPL1 1 Dental Prosthetic Laboratory $79,766.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 2 $67.00 $134.00C01D0 Cabinet, Base, 4 Drawer,36x18x22 1 $780.00 $780.00C02B0 Cabinet, Base, 2 Shelf, 1 Door,36x24x22 1 $883.00 $883.00C03F0 Cabinet, Base, 1 Shelf, 2 Half-Drawer, 2 Door, 36x30x22 2 $1,024.00 $2,048.00______Lessor Gov't_______Part III: Special Requirements -- Schedule BMAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXX___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]Department / Functional AreaRoomCodeQty <strong>of</strong>Rooms FunctionSCHEDULE B--SPECIAL REQUIREMENTS: Functional Room ListEquipmentSymbol orJSN Code Item Description Qty Unit Cost Extension Subtotal NotesC03G0 Cabinet, Base, 2 Shelf, 2 Door,36x30x22 2 $744.00 $1,488.00C03P0 Cabinet, Sink, 2 Door, 30" W 1 $915.00 $915.00C04F0 Cabinet, Base, 1 Shelf, 2 HalfDrawer, 2 Door, 36x36x22 2 $1,100.00 $2,200.00C04G0 Cabinet, Base, 2 Shelf, 2 Door,36x36x22 1 $1,024.00 $1,024.00C05P0 Cabinet,Sink, 2 Door, 36x48x22 1 $1,052.00 $1,052.00C06M0CE030CE040CE050CS090CS200CT050D0666D0755D0795Cabinet, Under Counter, Pull-outBoard, 2 Drawer, 1 File Drawer,30x18x22 1 $863.00 $863.00Cabinet, Wall, 2 Shelf, GlassDoors, Sloping Top, 38x30x13 1 $789.00 $789.00Cabinet, Wall, 2 Shelf, 2 GlassDoors, Sloping Top, 38x36x13 4 $1,187.00 $4,748.00Cabinet, Wall, 2 Shelf, 2 GlassDoors, Sloping Top, 38x48x13 1 $1,321.00 $1,321.00Sink, SS, Single Compartment,7.5x19x16 ID 1 $912.00 $912.00Sink, SS, Single Compartment,12x28x16 ID 1 $1,228.00 $1,228.00Countertop, SS, w/IntegralBacksplash 28 $531.00 $14,868.00Cabinet, Wall Hung, DentalLaboratory, 30x48x12 1 $860.00 $860.00Tank Assenbly, Boilout / curing,Double 1 $3,446.00 $3,446.00Sink, SS, 18 gauge, w/ faucet,11x18x14 1 $1,279.00 $1,279.00Dental DNSC2 1D0900 Workstation, Dental Lab, Receiving 1 $3,217.00 $3,217.00D0930 Workstation, Dental Lab, Casting 1 $8,091.00 $8,091.00D0960 Workstation, Dental Lab, Plaster 1 $11,902.00 $11,902.00D0980 Workstation, Dental Lab, Polishing,Single 3 $3,985.00 $11,955.00D8650 Chute, Waste, Plaster, CounterMounted 1 $239.00 $239.00D9280 Legs, Rail, Apron 2 $278.00 $556.00M2020 Cabinet, Storage, Safety, Built-in,Vented 1 $2,207.00 $2,207.00P1965 Eyewash, Eye/Face, Sink Mounted,Hands Free 1 $356.00 $356.00P7650 Trap, Plaster, Small 1 $405.00 $405.00Instrument Preparation andSterilization Room $109,879.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00C01D0 Cabinet, Base, 4 Drawer,36x18x22 1 $780.00 $780.00C01D0 Cabinet, Base, 4 Drawer,36x18x22 1 $780.00 $780.00______Lessor Gov't_______Part III: Special Requirements -- Schedule BMAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXX___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXDepartment / Functional AreaRoomCodeQty <strong>of</strong>Rooms FunctionSCHEDULE B--SPECIAL REQUIREMENTS: Functional Room ListEquipmentSymbol orJSN Code Item Description Qty Unit Cost Extension Subtotal NotesC03H0Cabinet, Base, 2 Half-Drawer, 3Door, 36x30x22 1 $1,498.00 $1,498.00Cabinet, Base, 1 Shelf, 2 HalfC04F0 Drawer, 2 Door, 36x36x22 2 $1,100.00 $2,200.00C04P0 Cabinet,Sink, 2 Door, 36x36x22 1 $994.00 $994.00Cabinet, Wall, 2 Shelf, 2 GlassCE040 Doors, Sloping Top, 38x36x13 3 $1,187.00 $3,561.00Sink, SS, Single Compartment,CS180 12x22x16 ID 1 $1,034.00 $1,034.00Countertop, SS, w/IntegralCT050 Backsplash 13 $531.00 $6,903.00CW090Cabinet, Floorstanding, 5 Shelves,2 Glass Doors, Steel 95x36x16 1 $1,996.00 $1,996.00CW100P1965S0237Cabinet, Floorstanding, 5 Shelves,2 Glass Doors, Steel 95x48x16 1 $2,707.00 $2,707.00Eyewash, Eye/Face, Sink Mounted,Hands Free 1 $356.00 $356.00Sterilizer, Electric, Vacuum, 2Door, Recessed, Thru Wall,20x20x38 Chamber 1 $77,612.00 $77,612.00S0965 Washer / Disinfector, Dental 1 $9,376.00 $9,376.00Dental LCCL1 NR Linen Room and Clean SPD Cart No Additional Schedule B ItemsDental LR002 1 Locker Room / Changing Area $812.00A1080 Mirror, Posture, Wall Mounted 1 $338.00 $338.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00A5165 Shelf T-45, SS, 12"w x 5"d 1 $55.00 $55.00A5020 Bech, Locker, Floor Mounted 1 $244.00 $244.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00A5180Track, Cubicle Curtain, SurfaceMounted 10 $7.00 $70.00Dental MECH1 NR Mechanical Room No Additional Schedule B ItemsDental OFC01 1 <strong>Office</strong> Chief $107.00A5155 Costumer, Wall, Executive 1 $107.00 $107.00Dental OFA02 1 <strong>Office</strong>, Administrative Assistant $30.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Dental OFD03 5 <strong>Office</strong>, Dentist $150.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Dental SEC01 1 <strong>Office</strong>, Secretary / Reception / Files/ Additional Clerk $30.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Dental DNTS1 1 Oral Surgery Room $2,202.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00A1130 Cabinet, Control, Nitrogen 1 $954.00 $954.00A1170 Track, IV, Ceiling Mounted, 4 foot 1 $954.00 $954.00Dispenser, Paper Towel, SS,A5080 Surface Mounted 2 $67.00 $134.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00A6025 Mirror, Safety, Convex 1 $70.00 $70.00Dental TLTU1 1 Patient Toilet $1,024.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00______Lessor Gov't_______Part III: Special Requirements -- Schedule B___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXDepartment / Functional AreaRoomCodeQty <strong>of</strong>Rooms FunctionSCHEDULE B--SPECIAL REQUIREMENTS: Functional Room ListEquipmentSymbol orJSN Code Item Description Qty Unit Cost Extension Subtotal NotesA5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5109 Grab Bars, SS, 1-1/2" Dia AR $175.00 $175.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00A5165 Shelf T-45, SS, 12"w x 5"d 1 $55.00 $55.00A5202 Dispenser, Toilet Paper w/UtilityShelf, SS, 2-Roll 1 $74.00 $74.00P-418 Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00P-103 Toilet, Wall Hung, w/seat 1 $265.00 $265.00Dental DNTR1 1 Recovery Room $8,574.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A1107 Rail System, Utility, Gas andElectric 1 $7,421.00 $7,421.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00A5180Track, Cubicle Curtain, SurfaceMounted 10 $7.00 $70.00M7425 Light, Overbed, Direct and Indirect 1 $561.00 $561.00P-418Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00Dental LCSL1 NR Soiled SPD Cart Holding No Additional Schedule B ItemsDental SRE01 NR Storage Room No Additional Schedule B ItemsDental WRC01 1 Waiting Area $436.00Bracket, Television, Wall Mounted,A5210 Adjustable Arm 1 $296.00 $296.00F2310 Rack, Pamphlet, Wall Mounted 1 $140.00 $140.00Dental DNXD1 1 X-Ray Area $3,109.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00D0795D9691D9835D9941X3150Sink, SS, 18 gauge, w/ faucet,11x18x14 1 $1,279.00 $1,279.00Cabinet, Base, Wall Hung, 4Drawers 1 $698.00 $698.00Cabinet, Sink, Wall Hung, 2 Doors,18x27x17 1 $712.00 $712.00Countertop, Laminated, 3/4-inchThick 6 $39.00 $234.00Rack, Apron / Gloves, WallMounted 1 $171.00 $171.00Education AreasEducation Areas CRA03 1 Educational Conference Room $3,407.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00F3055 Whiteboard, w/ Sliding Panels 1 $1,423.00 $1,423.00F3230 Rack, Hat / Coat, Wall Mounted 1 $102.00 $102.00M0400Screen, Projection, RecessedCeiling Mounted, ManualOperation, 105x140 Viewing Area,180" Diagonal 1 $1,852.00 $1,852.00______Lessor Gov't_______Part III: Special Requirements -- Schedule B___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXDepartment / Functional AreaRoomCodeQty <strong>of</strong>Rooms FunctionSCHEDULE B--SPECIAL REQUIREMENTS: Functional Room ListEquipmentSymbol orJSN Code Item Description Qty Unit Cost Extension Subtotal NotesEducation Areas OFA03 1 Instruction Area $114.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00F3010 Bulletin Board, 48" x 48" 1 $84.00 $84.00Electro-Encephalography Laboratory (EEG)EEG OPEE1 2 EEG Exam Room $1,136.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00A5080Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00A5180 Track, Cubicle Curtain, SurfaceMounted 10 $7.00 $70.00M1620 Holder, Chart, Patient, Wall orDoor Mounted 1 $28.00 $28.00P-418 Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00EEG OPEE2 1 EEG Instrument and Work Room $380.00A5080Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00P-418 Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00EEG OFA02 2 <strong>Office</strong>, Technician $60.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00EEG MRS01 NR Storage, EEG Records No Additional Schedule B ItemsDigestive Diseases Program--EndoscopyEndoscopy DR001 4 Changing Area, Patient $1,344.00A1066 Mirror, SS Framed, 20x48 1 $95.00 $95.00A5021 Bench, Dressing, Wall Mounted 1 $211.00 $211.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Endoscopy RROP1 1 Cubicle, Patient Recovery $18,427.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00Rail System, Utility, Gas andA1107 Electric 2 $7,421.00 $14,842.00A1165 Track, IV, Ceiling Mounted, 7 foot 4 $425.00 $1,700.00Dispenser, Paper Towel, SS,A5080 Surface Mounted 1 $67.00 $67.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00A5180Track, Cubicle Curtain, SurfaceMounted 44 $7.00 $308.00M7425 Light, Overbed, Direct and Indirect 2 $561.00 $1,122.00P-418Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00Endoscopy XVC01 1 Dictation / Viewing Room $580.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00X3900Illuminator, Film, Double,Recessed 1 $550.00 $550.00______Lessor Gov't_______Part III: Special Requirements -- Schedule B___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]Department / Functional AreaRoomCodeQty <strong>of</strong>Rooms FunctionSCHEDULE B--SPECIAL REQUIREMENTS: Functional Room ListEquipmentSymbol orJSN Code Item Description Qty Unit Cost Extension Subtotal NotesEndoscopy TREE1 2 EGD Procedure Room $5,820.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5180 Track, Cubicle Curtain, SurfaceMounted 12 $7.00 $84.00A5165 Shelf T-45, SS, 12"w x 5"d 1 $55.00 $55.00Lavatory, Vitreous China, withP-418 Sensor Faucet 1 $298.00 $298.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00M1620Holder, Chart, Patient, Wall orDoor Mounted 1 $28.00 $28.00M7405 Light, Exam, Ceiling Mounted 1 $2,348.00 $2,348.00Endoscopy JANC1 1 Housekeeping Aids Closet (HAC) $1,934.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5135 Rack, Mop, T-10, Wall Mounted 1 $211.00 $211.00CD045 Cabinet, SS, Wall, T-7, 2 Shelf, 2Doors, Sloping Top, 36x48x12 1 $1,242.00 $1,242.00P-502 Sink, Service, Corner, FloorMounted 1 $414.00 $414.00Endoscopy NSTA4 1 Nurse Station $7,911.00C0045 Frame, Apron, 1 Drawer, 4x36x22 1 $420.00 $420.00C0046 Frame, Apron, 2 Drawer, 4x48x22 1 $629.00 $629.00C06M0C09F0C09G0CG040CG050Cabinet, Under Counter, Pull-outBoard, 2 Drawer, 1 File Drawer,30x18x22 1 $863.00 $863.00Cabinet, Under Counter, 2 Half-Drawer, 2 Door, 30" W 1 $1,175.00 $1,175.00Cabinet, Under Counter, 1 Shelf, 2Door, 30x36x22 1 $930.00 $930.00Cabinet, Wall, 2 Shelf, SlidingGlass Door, Sloping Top,38x36x13 1 $1,291.00 $1,291.00Cabinet, Wall, 2 Shelf, SlidingGlass Door, Sloping Top,38x48x13 1 $1,427.00 $1,427.00Countertop, High PressureCT030 Laminate 14 $70.00 $980.00F3050 Whiteboard, Dry Erase 1 $196.00 $196.00Endoscopy OFD03 1 <strong>Office</strong>, GI Assistant $30.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Endoscopy RECP1 1 Reception Area $2,812.00C0038 Rail, Apron, 4x42x1 1 $116.00 $116.00C0039 Rail, Apron, 4x48x1 1 $84.00 $84.00C0045 Frame, Apron, 1 Drawer, 4x36x22 1 $420.00 $420.00C0046 Frame, Apron, 2 Drawer, 4x48x22 1 $629.00 $629.00C06M0Cabinet, Under Counter, Pull-outBoard, 2 Drawer, 1 File Drawer,30x18x22 1 $863.00 $863.00______Lessor Gov't_______Part III: Special Requirements -- Schedule BMAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXX___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXDepartment / Functional AreaRoomCodeEndoscopy USCL2 1Qty <strong>of</strong>Rooms FunctionSCHEDULE B--SPECIAL REQUIREMENTS: Functional Room ListEquipmentSymbol orJSN Code Item Description Qty Unit Cost Extension Subtotal NotesCT030Countertop, High PressureLaminate 10 $70.00 $700.00Scopes Clean-up, Sterilization andStorage Room $15,385.00Dispenser, Paper Towel, SS,A5080 Surface Mounted 1 $67.00 $67.00Scope WashCabinet, Base, 1 Shelf, 1 Drawer, 1C02C0 Door, 36x24x22 1 $898.00 $898.00Scope WashC05P0 Cabinet,Sink, 2 Door, 36x48x22 1 $1,052.00 $1,052.00 Scope WashCG040CS200CT050C02C0CG040CT030E0918Cabinet, Wall, 2 Shelf, SlidingGlass Door, Sloping Top,38x36x13 2 $1,291.00 $2,582.00Sink, SS, Single Compartment,12x28x16 ID 1 $1,228.00 $1,228.00Countertop, SS, w/IntegralBacksplash 6 $531.00 $3,186.00Cabinet, Base, 1 Shelf, 1 Drawer, 1Door, 36x24x22 2 $898.00 $1,796.00Cabinet, Wall, 2 Shelf, SlidingGlass Door, Sloping Top,38x36x13 2 $1,291.00 $2,582.00Countertop, High PressureLaminate 6 $70.00 $420.00Cabinet, Scope Storage, Metal,Floorstanding, 2 Glass Doors,Sloping Top 36x72x12 1 $1,574.00 $1,574.00Scope WashScope WashClean StorageClean StorageClean StorageClean StorageEndoscopy RCA01 NR Storage, Crash Cart No Additional Schedule B ItemsEndoscopy TLTU1 3 Toilet, Patient $3,072.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5109 Grab Bars, SS, 1-1/2" Dia AR $175.00 $175.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00A5165 Shelf T-45, SS, 12"w x 5"d 1 $55.00 $55.00A5202 Dispenser, Toilet Paper w/UtilityShelf, SS, 2-Roll 1 $74.00 $74.00P-418 Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00P-103 Toilet, Wall Hung, w/seat 1 $265.00 $265.00Endoscopy UCCL1 1 Utility Room, Clean $946.00CD040 Cabinet, Metal, Wall, T-5B, 2 Shelf,2 Doors, Sloping Top, 36x42x22 1 $946.00 $946.00Endoscopy USCL1 1 Utility Room, Soiled $894.00P-418 Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00P-505 Sink, Service, Clinical Flushing rim,Wall Hung 1 $596.00 $596.00Endoscopy WRC01 1 Waiting Area $436.00Bracket, Television, Wall Mounted,A5210 Adjustable Arm 1 $296.00 $296.00F2310 Rack, Pamphlet, Wall Mounted 1 $140.00 $140.00______Lessor Gov't_______Part III: Special Requirements -- Schedule B___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXDepartment / Functional AreaEngineeringRoomCodeEngineering BMER1 1Qty <strong>of</strong>Rooms FunctionSCHEDULE B--SPECIAL REQUIREMENTS: Functional Room ListEquipmentSymbol orJSN Code Item Description Qty Unit Cost Extension Subtotal NotesBiomedical Engineering RepairShop $10,795.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00 Biomedical EngineerDispenser, Paper Towel, SS,Receiving and CleaningA5080 Surface Mounted 1 $67.00 $67.00Sink, SS, Single Compartment,17.5x21x12 ID, w/ IntegralReceiving and CleaningP-514 Drainboard (w/out corrugations) 1 $2,575.00 $2,575.00Rail System, Utility, Gas andRepairA1107 Electric 1 $7,421.00 $7,421.00F3025 Bulletin Board, Wood Framed 1 $54.00 $54.00 RepairM2055Shelving, Floorstanding, Steel, 5Adjustable Shelves, 36x84x18 2 $324.00 $648.00StorageEnvironmental <strong>Management</strong> (EMS)EMS UTC01 NR Dumpsters No Additional Schedule B ItemsEMS JANC1 7 Housekeeping Aids Closet (HAC) $13,538.00 One per 13,000 nsf; distribute throughout OPCA5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5135 Rack, Mop, T-10, Wall Mounted 1 $211.00 $211.00CD045 Cabinet, SS, Wall, T-7, 2 Shelf, 2Doors, Sloping Top, 36x48x12 1 $1,242.00 $1,242.00P-502 Sink, Service, Corner, FloorMounted 1 $414.00 $414.00EMS SHRHM1 NR Infectious / Hazardous Waste No Additional Schedule B ItemsEMS OFA02 1 <strong>Office</strong>, Chief $30.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00EMS SEC01 1 <strong>Office</strong>, Secretary and Waiting $30.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00EMS UTC01 NR Recyclable Waste No Additional Schedule B ItemsEMS LCCL1 NR Storage, Clean linen Cart No Additional Schedule B ItemsEMS SRSE1 1 Storage, Environmental<strong>Management</strong> Supplies / LargeEquipment $1,296.00M2055 Shelving, Floorstanding, Steel, 5Adjustable Shelves, 36x84x18 4 $324.00 $1,296.00EMS LCSL1 NR Storage, Soiled Linen Cart No Additional Schedule B ItemsEye ClinicEye Clinic TREY1 1 Exam / Treatment Room $4,828.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00M1620 Holder, Chart, Patient, Wall orDoor Mounted 1 $28.00 $28.00M5016 Desk, Refraction w/console, w/osink 1 $4,330.00 $4,330.00P-418 Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00Eye Clinic EYFD1 1 Fitting and Dispensing Room $470.00______Lessor Gov't_______Part III: Special Requirements -- Schedule B___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXDepartment / Functional AreaRoomCodeEye Clinic OFA02 1Qty <strong>of</strong>Rooms FunctionSCHEDULE B--SPECIAL REQUIREMENTS: Functional Room ListEquipmentSymbol orJSN Code Item Description Qty Unit Cost Extension Subtotal NotesA1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00P-418Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00<strong>Office</strong>, Blind Rehabilitation (VIST),Counselor $30.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Eye Clinic OFD03 6 <strong>Office</strong>, Eye Care Provider $180.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Eye Clinic EYVS1 1 Photography Room $498.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00M1620 Holder, Chart, Patient, Wall orDoor Mounted 1 $28.00 $28.00P-418 Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00Eye Clinic RECP1 1 Reception Area $2,812.00C0038 Rail, Apron, 4x42x1 1 $116.00 $116.00C0039 Rail, Apron, 4x48x1 1 $84.00 $84.00C0045 Frame, Apron, 1 Drawer, 4x36x22 1 $420.00 $420.00C0046 Frame, Apron, 2 Drawer, 4x48x22 1 $629.00 $629.00C06M0CT030Cabinet, Under Counter, Pull-outBoard, 2 Drawer, 1 File Drawer,30x18x22 1 $863.00 $863.00Countertop, High PressureLaminate 10 $70.00 $700.00Eye Clinic EYVF1 1 Visual Fields Room $498.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00M1620 Holder, Chart, Patient, Wall orDoor Mounted 1 $28.00 $28.00P-418 Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00Eye Clinic WRC01 1 Waiting Area (Dilation) $436.00Bracket, Television, Wall Mounted,A5210 Adjustable Arm 1 $296.00 $296.00F2310 Rack, Pamphlet, Wall Mounted 1 $140.00 $140.00Healthcare Adminstration (HAS)Healthcare Adminstration (HAS) SRSE1 NR Supplemental Equipment Space No Additional Schedule B ItemsHealthcare Adminstration (HAS) OFA02 19 Workstation / <strong>Office</strong> $570.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Healthcare Adminstration (HAS) OFC02 1 <strong>Office</strong>, Chief $107.00A5155 Costumer, Wall, Executive 1 $107.00 $107.00Healthcare Adminstration (HAS) SEC01 1 <strong>Office</strong>, Secretary and Waiting $30.00______Lessor Gov't_______Part III: Special Requirements -- Schedule B___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXDepartment / Functional AreaRoomCodeQty <strong>of</strong>Rooms FunctionSCHEDULE B--SPECIAL REQUIREMENTS: Functional Room ListEquipmentSymbol orJSN Code Item Description Qty Unit Cost Extension Subtotal NotesA5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Healthcare Adminstration (HAS) RPR01 NR Copy Room No Additional Schedule B ItemsLobbyLobby OFA02 1 Escort Room $30.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Lobby RECP3 1 Information Desk $3,232.00C0038 Rail, Apron, 4x42x1 1 $116.00 $116.00C0039 Rail, Apron, 4x48x1 1 $84.00 $84.00C0045 Frame, Apron, 1 Drawer, 4x36x22 1 $420.00 $420.00C0046 Frame, Apron, 2 Drawer, 4x48x22 1 $629.00 $629.00C06M0CT030Cabinet, Under Counter, Pull-outBoard, 2 Drawer, 1 File Drawer,30x18x22 1 $863.00 $863.00Countertop, High PressureLaminate 16 $70.00 $1,120.00Lobby LOB01 1 Public Telephones $250.00F3025 Bulletin Board, Wood Framed 1 $54.00 $54.00F3050 Whiteboard, Dry Erase 1 $196.00 $196.00Lobby SRLW1 NR Storage, Wheelchair No Additional Schedule B ItemsLobby TLTU1 1 Toilet, Female, Public $1,024.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5109 Grab Bars, SS, 1-1/2" Dia AR $175.00 $175.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00A5165 Shelf T-45, SS, 12"w x 5"d 1 $55.00 $55.00A5202 Dispenser, Toilet Paper w/UtilityShelf, SS, 2-Roll 1 $74.00 $74.00P-418 Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00P-103 Toilet, Wall Hung, w/seat 1 $265.00 $265.00Lobby TLTU1 1 Toilet, Male, Public $1,024.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5109 Grab Bars, SS, 1-1/2" Dia AR $175.00 $175.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00A5165 Shelf T-45, SS, 12"w x 5"d 1 $55.00 $55.00A5202 Dispenser, Toilet Paper w/UtilityShelf, SS, 2-Roll 1 $74.00 $74.00P-418 Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00P-103 Toilet, Wall Hung, w/seat 1 $265.00 $265.00Lobby WRC01 1 Waiting Area $436.00Bracket, Television, Wall Mounted,A5210 Adjustable Arm 1 $296.00 $296.00F2310 Rack, Pamphlet, Wall Mounted 1 $140.00 $140.00EMS: Lockers, Lounges, Toilets and Showers (LLTS)EMS: LLTS LR002 1 Locker Room $797.00______Lessor Gov't_______Part III: Special Requirements -- Schedule B___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXDepartment / Functional AreaRoomCodeQty <strong>of</strong>Rooms FunctionSCHEDULE B--SPECIAL REQUIREMENTS: Functional Room ListEquipmentSymbol orJSN Code Item Description Qty Unit Cost Extension Subtotal NotesA1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00A1080 Mirror, Posture, Wall Mounted 1 $338.00 $338.00A5020 Bench, Locker, Floor Mounted 1 $244.00 $244.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00A5165 Shelf T-45, SS, 12"w x 5"d 1 $55.00 $55.00A5180 Track, Cubicle Curtain, SurfaceMounted 10 $7.00 $70.00EMS: LLTS TLTS1 1 Shower, Female Staff $2,323.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00A5030 Bench, Shower, Built-in 1 $618.00 $618.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5090 Disposal, Sanitary Napkin, SS,Surface Mounted 1 $44.00 $44.00A5109 Grab Bars, SS, 1-1/2" Dia AR $175.00 $175.00A5110 Grab Bar, SS, 1-1/2" Dia, ShowerUse AR $175.00 $175.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00A5165 Shelf T-45, SS, 12"w x 5"d 1 $55.00 $55.00A5170 Rod, Shower curtain, 1"dia,w/curtain and hooks 1 $48.00 $48.00A5175 Soap Dish, SS, Recessed 1 $30.00 $30.00A5202 Dispenser, Toilet Paper w/UtilityShelf, SS, 2-Roll 1 $74.00 $74.00A5205 Bar, Towel, 1" dia, SS, SurfaceMounted 1 $40.00 $40.00P-103 Toilet, Wall Hung, w/seat 1 $265.00 $265.00P-418Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00P-703 Shower, Single, Hand Held 1 $344.00 $344.00EMS: LLTS TLTS1 1 Shower, Male Staff $2,279.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00A5030 Bench, Shower, Built-in 1 $618.00 $618.00Dispenser, Paper Towel, SS,A5080 Surface Mounted 1 $67.00 $67.00A5109 Grab Bars, SS, 1-1/2" Dia AR $175.00 $175.00A5110 Grab Bar, SS, 1-1/2" Dia, ShowerUse AR $175.00 $175.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00A5165 Shelf T-45, SS, 12"w x 5"d 1 $55.00 $55.00A5170 Rod, Shower curtain, 1"dia,w/curtain and hooks 1 $48.00 $48.00A5175 Soap Dish, SS, Recessed 1 $30.00 $30.00A5202 Dispenser, Toilet Paper w/UtilityShelf, SS, 2-Roll 1 $74.00 $74.00A5205 Bar, Towel, 1" dia, SS, SurfaceMounted 1 $40.00 $40.00P-103 Toilet, Wall Hung, w/seat 1 $265.00 $265.00P-418Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00P-703 Shower, Single, Hand Held 1 $344.00 $344.00EMS: LLTS TLTU1 10 Toilet, Staff $10,240.00 Distributed through Clinic DepartmentsA1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00______Lessor Gov't_______Part III: Special Requirements -- Schedule B___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]Department / Functional AreaRoomCodeQty <strong>of</strong>Rooms FunctionSCHEDULE B--SPECIAL REQUIREMENTS: Functional Room ListEquipmentSymbol orJSN Code Item Description Qty Unit Cost Extension Subtotal NotesA5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5109 Grab Bars, SS, 1-1/2" Dia AR $175.00 $175.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00A5165 Shelf T-45, SS, 12"w x 5"d 1 $55.00 $55.00A5202 Dispenser, Toilet Paper w/UtilityShelf, SS, 2-Roll 1 $74.00 $74.00P-418 Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00P-103 Toilet, Wall Hung, w/seat 1 $265.00 $265.00Mental HealthAdministration OPMH1 3 Group Therapy Room $1,200.00A5120 Window, Observation, One-Way 1 $400.00 $400.00Administration OFA02 1 <strong>Office</strong>, Director $30.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Administration SEC01 1 <strong>Office</strong>, Secretary / Clerical $30.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Administration RECP1 1 Reception / Control Unit $2,812.00C0038 Rail, Apron, 4x42x1 1 $116.00 $116.00C0039 Rail, Apron, 4x48x1 1 $84.00 $84.00C0045 Frame, Apron, 1 Drawer, 4x36x22 1 $420.00 $420.00C0046 Frame, Apron, 2 Drawer, 4x48x22 1 $629.00 $629.00C06M0CT030Cabinet, Under Counter, Pull-outBoard, 2 Drawer, 1 File Drawer,30x18x22 1 $863.00 $863.00Countertop, High PressureLaminate 10 $70.00 $700.00Administration TLTU1 3 Toilet $3,072.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5109 Grab Bars, SS, 1-1/2" Dia AR $175.00 $175.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00A5165 Shelf T-45, SS, 12"w x 5"d 1 $55.00 $55.00A5202 Dispenser, Toilet Paper w/UtilityShelf, SS, 2-Roll 1 $74.00 $74.00P-418 Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00P-103 Toilet, Wall Hung, w/seat 1 $265.00 $265.00Day Treatment Center OFDC1 5 <strong>Office</strong> $150.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Day Treatment Center OFDC1 1 <strong>Office</strong>, Chief $107.00A5155 Costumer, Wall, Executive 1 $107.00 $107.00Social Activities / Dining /Day Treatment Center FSCD1 NR MultipurposeDay Treatment Center FSNP1 1 Social Activities Space / Kitchen $1,679.00A5080Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00K6300 Sink, Cook's, SS, 1 Compartment 1 $1,612.00 $1,612.00______Lessor Gov't_______Part III: Special Requirements -- Schedule BMAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXNo Additional Schedule B Items___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXDepartment / Functional AreaRoomCodeQty <strong>of</strong>Rooms FunctionSCHEDULE B--SPECIAL REQUIREMENTS: Functional Room ListEquipmentSymbol orJSN Code Item Description Qty Unit Cost Extension Subtotal NotesDay Treatment Center SRS01 NR Social Activities Space / Storage No Additional Schedule B ItemsMental Health Clinic OPMH3 1Bi<strong>of</strong>eedback Control Room / Tech<strong>Office</strong> $211.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00F3050 Whiteboard, Dry Erase 1 $196.00 $196.00Mental Health Clinic OPMH3 1 Bi<strong>of</strong>eedback Treatment Room $611.00A5120 Window, Observation, One-Way 1 $400.00 $400.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00F3050 Whiteboard, Dry Erase 1 $196.00 $196.00Mental Health Clinic EXRG3 1 Exam / Treatment Room $665.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5180 Track, Cubicle Curtain, SurfaceMounted 16 $7.00 $112.00A5165 Shelf T-45, SS, 12"w x 5"d 1 $55.00 $55.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00Lavatory, Vitreous China, withP-418 Sensor Faucet 1 $298.00 $298.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00M1620Holder, Chart, Patient, Wall orDoor Mounted 1 $28.00 $28.00Mental Health Clinic OFDC1 30 <strong>Office</strong> $900.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Mental Health Clinic OFDC1 1 <strong>Office</strong>, Chief $107.00A5155 Costumer, Wall, Executive 1 $107.00 $107.00Methadone Maintenance Program MEDP1 1 Medication / Treatment Room $7,673.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00C04P0 Cabinet,Sink, 2 Door, 36x36x22 1 $994.00 $994.00C02D0 Cabinet, Base, 4 Drawer,36x24x22 1 $1,087.00 $1,087.00CT050 Countertop, SS, w/IntegralBacksplash 6 $531.00 $3,186.00CS090 Sink, SS, Single Compartment,Intergal w/ SS Top, 7.5x19x16 ID 1 $912.00 $912.00CG050Cabinet, Wall, 2 Shelf, SlidingGlass Door, Sloping Top,38x48x13 1 $1,427.00 $1,427.00Methadone Maintenance Program PHDS1 1 Methadone Dispensing Pharmacy $365.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00P-418 Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00Methadone Maintenance Program OFD03 1<strong>Office</strong> / Exam Room, NursePractitioner $30.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Methadone Maintenance Program SSV01 NR Storage / Vault No Additional Schedule B ItemsMethadone Maintenance Program TLTU1 1 Toilet, Urine Specimen Collection $1,024.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00A5080Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00______Lessor Gov't_______Part III: Special Requirements -- Schedule B___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXDepartment / Functional AreaRoomCodeQty <strong>of</strong>Rooms FunctionSCHEDULE B--SPECIAL REQUIREMENTS: Functional Room ListEquipmentSymbol orJSN Code Item Description Qty Unit Cost Extension Subtotal NotesA5109 Grab Bars, SS, 1-1/2" Dia AR $175.00 $175.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00A5165 Shelf T-45, SS, 12"w x 5"d 1 $55.00 $55.00A5202P-418Dispenser, Toilet Paper w/UtilityShelf, SS, 2-Roll 1 $74.00 $74.00Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00P-103 Toilet, Wall Hung, w/seat 1 $265.00 $265.00Methadone Maintenance Program WRC01 1 Waiting Area $436.00A5210 Bracket, Television, Wall Mounted,Adjustable Arm 1 $296.00 $296.00F2310 Rack, Pamphlet, Wall Mounted 1 $140.00 $140.00Occupational Therapy OTDL1 1 Basic Clinic $7,281.00Dispenser, Paper Towel, SS,A5080 Surface Mounted 1 $67.00 $67.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00A5180Track, Cubicle Curtain, SurfaceMounted 12 $7.00 $84.00A5195 Dispenser, Toilet Paper, SS, 1-Roll 1 $13.00 $13.00A5205 Bar, Towel, 1" dia, SS, SurfaceMounted 1 $40.00 $40.00C04E0 Cabinet, Base, 1 Shelf, 1 Drawer, 2Door, 36x36x22 1 $1,207.00 $1,207.00C05P0 Cabinet,Sink, 2 Door, 36x48x22 1 $1,052.00 $1,052.00CE090 Cabinet, Wall, 2 Shelf, GlassDoors, Sloping Top, 41x36x13 1 $1,198.00 $1,198.00CS070 Sink, SS, Single Compartment,7.5x16x16 ID 1 $778.00 $778.00CS180 Sink, SS, Single Compartment,12x22x16 ID 1 $1,034.00 $1,034.00CT030 Countertop, High PressureLaminate 25 $70.00 $1,750.00M1620 Holder, Chart, Patient, Wall orDoor Mounted 1 $28.00 $28.00Occupational Therapy SRS01 NR Storage No Additional Schedule B ItemsSubstance Abuse Clinic OFDC1 4 <strong>Office</strong> $120.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Substance Abuse Clinic OFD03 2 <strong>Office</strong> $60.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Substance Abuse Clinic SEC01 1 <strong>Office</strong>, Secretary / Clerical $30.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Substance Abuse Clinic OFA02 1 <strong>Office</strong> Statistical Clerk $30.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Substance Abuse Clinic SRS01 NR Utility and Storage No Additional Schedule B ItemsPathology and Laboratory Medicine (PLM)Laboratories LBVP1 1 Blood Specimen Collection Room $4,188.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00C02D0 Cabinet, Base, 4 Drawer,36x24x22 1 $1,087.00 $1,087.00______Lessor Gov't_______Part III: Special Requirements -- Schedule B___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]Department / Functional AreaRoomCodeQty <strong>of</strong>Rooms FunctionSCHEDULE B--SPECIAL REQUIREMENTS: Functional Room ListEquipmentSymbol orJSN Code Item Description Qty Unit Cost Extension Subtotal NotesC03F0 Cabinet, Base, 1 Shelf, 2 Half-Drawer, 2 Door, 36x30x22 1 $1,024.00 $1,024.00CA040 Cabinet, Wall, Open, 2 Shelf,Sloping Top, 38x36x13 2 $646.00 $1,292.00CT030 Countertop, High PressureLaminate 6 $70.00 $420.00P-414 Lavatory, Vitreous China, withWrist Blade Faucet 1 $298.00 $298.00Laboratories LMCH1 1 Clinical Chemistry $30,948.00A5080Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00C0045 Frame, Apron, 1 Drawer, 4x36x22 2 $420.00 $840.00C02C0 Cabinet, Base, 1 Shelf, 1 Drawer, 1Door, 36x24x22 4 $898.00 $3,592.00C05P0 Cabinet,Sink, 2 Door, 36x48x22 1 $1,052.00 $1,052.00Cabinet, Under Counter, Pull-outBoard, 2 Drawer, 1 File Drawer,C06M0 30x18x22 2 $863.00 $1,726.00Cabinet, Under Counter, 2 Half-C09F0 Drawer, 2 Door, 30x30x22 2 $1,175.00 $2,350.00Cabinet, Wall, Open, 2 Shelf,CA020 Sloping Top, 24x30x13 6 $581.00 $3,486.00Cabinet, Wall, 2 Shelf, 2 GlassCE040 Doors, Sloping Top, 38x36x13 4 $1,187.00 $4,748.00CS270 Sink, Epoxy Resin, 11x18x15 ID 2 $538.00 $1,076.00CT060 Countertop, Modified Epoxy Resin 40 $146.00 $5,840.00P5210Eyewash and Safety Shower,Floorstanding 1 $1,795.00 $1,795.00VL-54 Pegboard, Epoxy, 53 pegs, 32x30 1 $926.00 $926.00Outlets, Lab Gas: Gas, Air,Vaccum 6 $575.00 $3,450.00Laboratories LMM03 1 Clinical Microbiology $25,738.00A5080Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00C0045 Frame, Apron, 1 Drawer, 4x36x22 1 $420.00 $420.00C0046 Frame, Apron, 2 Drawer, 4x48x22 1 $629.00 $629.00C02C0 Cabinet, Base, 1 Shelf, 1 Drawer, 1Door, 36x24x22 2 $898.00 $1,796.00C04P0 Cabinet,Sink, 2 Door, 36x36x22 2 $994.00 $1,988.00CA020 Cabinet, Wall, Open, 2 Shelf,Sloping Top, 24x30x13 4 $581.00 $2,324.00CE040 Cabinet, Wall, 2 Shelf, 2 GlassDoors, Sloping Top, 38x36x13 1 $1,187.00 $1,187.00CS270 Sink, Epoxy Resin, 11x18x15 ID 2 $538.00 $1,076.00CT060 Countertop, Modified Epoxy Resin 18 $146.00 $2,628.00F3010 Bulletin Board, 48" x 48" 1 $84.00 $84.00______Lessor Gov't_______Part III: Special Requirements -- Schedule BMAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXX___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXDepartment / Functional AreaRoomCodeQty <strong>of</strong>Rooms FunctionSCHEDULE B--SPECIAL REQUIREMENTS: Functional Room ListEquipmentSymbol orJSN Code Item Description Qty Unit Cost Extension Subtotal NotesDispenser, Paper Towel, SS,A5080 Surface Mounted 2 $67.00 $134.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00L2335 Cabinet, Biosafety, Class 2, B2, 4ft 1 $12,449.00 $12,449.00Laboratories LBSM1 1VL-54 Pegboard, Epoxy, 53 pegs, 32x30 1 $926.00 $926.00Sterilization and SolutionPreparation Room $54,828.00Dispenser, Paper Towel, SS,A5080 Surface Mounted 1 $67.00 $67.00L2000 Purification System, Water 1 $6,025.00 $6,025.00S0145Sterilizer, Electric, Gravity, Lab, 1Door, Cabinet enclosed, 16x16x26chamber 1 $48,736.00 $48,736.00Laboratories SRS01 NR Storage, Bulk No Additional Schedule B ItemsLaboratories SRR02 NR Storage, Refrigerated No Additional Schedule B ItemsLaboratories TLTU1 1 Toilet, Urine Specimen Collection $1,024.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5109 Grab Bars, SS, 1-1/2" Dia AR $175.00 $175.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00A5165 Shelf T-45, SS, 12"w x 5"d 1 $55.00 $55.00A5202 Dispenser, Toilet Paper w/UtilityShelf, SS, 2-Roll 1 $74.00 $74.00P-418 Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00P-103 Toilet, Wall Hung, w/seat 1 $265.00 $265.00Laboratories WRC01 1 Waiting Area, Patient $436.00Bracket, Television, Wall Mounted,A5210 Adjustable Arm 1 $296.00 $296.00F2310 Rack, Pamphlet, Wall Mounted 1 $140.00 $140.00PLM OFA02 1 <strong>Office</strong>, Chief Medical Technologist $30.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00PLM OFD03 1<strong>Office</strong>, Pathologist and MicroscopeArea $30.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00PLM SEC01 1 <strong>Office</strong>, Secretary / Clerical $30.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00PharmacyNon-Secure Areas OFDC2 1 Consultation Room $30.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Non-Secure Areas OFA03 1 Prescription Receiving $99.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00F3010 Bulletin Board, 48" x 48" 1 $84.00 $84.00Non-Secure Areas WRC01 1 Waiting Area $436.00Bracket, Television, Wall Mounted,A5210 Adjustable Arm 1 $296.00 $296.00F2310 Rack, Pamphlet, Wall Mounted 1 $140.00 $140.00______Lessor Gov't_______Part III: Special Requirements -- Schedule B___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXDepartment / Functional AreaRoomCodeQty <strong>of</strong>Rooms FunctionSCHEDULE B--SPECIAL REQUIREMENTS: Functional Room ListEquipmentSymbol orJSN Code Item Description Qty Unit Cost Extension Subtotal NotesSecure Areas OFA03 1 Data Processing Space $99.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00F3010 Bulletin Board, 48" x 48" 1 $84.00 $84.00Secure Areas PHOD2 1 Dispensing $365.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00P-414 Lavatory, Vitreous China, withWrist Blade Faucet 1 $298.00 $298.00Secure Areas PHBS1 NR Drug Receiving, Breakdown andVerification AreaSecure Areas PHMP1 1 Extemporaneous Compounding $67.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00Secure Areas PHOD1 1 Filling and Assembly $916.00Dispenser, Paper Towel, SS,A5080 Surface Mounted 1 $67.00 $67.00P1960 Eyewash, Countertop 1 $551.00 $551.00P-414Lavatory, Vitreous China, withWrist Blade Faucet 1 $298.00 $298.00No Additional Schedule B ItemsSecure Areas PHMP2 NR Mail Out No Additional Schedule B ItemsSecure Areas OFA02 7 <strong>Office</strong> $210.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Secure Areas SEC01 1 <strong>Office</strong>, Secretary and Waiting $30.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Secure Areas PHIV3 1 Oncology: Preparation Area $12,449.00 Comply with USP Secure Areas XXYYC 1Secure Areas PHBS2 1L2335 Cabinet, Biosafety, Class 2, B2, 4ft 1 $12,449.00 $12,449.00Oncology: Preparation AreaAnteroom $2,419.00Dispenser, Paper Towel, SS,A5080 Surface Mounted 1 $67.00 $67.00F3230 Rack, Hat / Coat, Wall Mounted 1 $102.00 $102.00P-520Sink, Surgeon's Scrub, SensorControl, 28x22 1 $2,250.00 $2,250.00Oncology: Storage and Clean /Decontamination Area $4,674.00C03G0CT050Cabinet, SS, Base, 2 Shelf, 2 Door,36x30x22 2 $744.00 $1,488.00Countertop, SS, w/IntegralBacksplash 6 $531.00 $3,186.00Comply with USP Comply with USP Secure Areas XXYYC 1 Oncology: Clean Corridor $426.00 Comply with USP F3230 Rack, Hat / Coat, Wall Mounted 1 $102.00 $102.00Secure Areas JANC1 1M2055Shelving, Floorstanding, Steel, 5Adjustable Shelves, 36x84x18 1 $324.00 $324.00Oncology: Housekeeping AidsCloset HAC $1,934.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5135 Rack, Mop, T-10, Wall Mounted 1 $211.00 $211.00CD045 Cabinet, SS, Wall, T-7, 2 Shelf, 2Doors, Sloping Top, 36x48x12 1 $1,242.00 $1,242.00P-502 Sink, Service, Corner, FloorMounted 1 $414.00 $414.00Comply with USP ______Lessor Gov't_______Part III: Special Requirements -- Schedule B___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXDepartment / Functional AreaRoomCodeQty <strong>of</strong>Rooms FunctionSCHEDULE B--SPECIAL REQUIREMENTS: Functional Room ListEquipmentSymbol orJSN Code Item Description Qty Unit Cost Extension Subtotal NotesSecure Areas OFA03 1 Oncology: Reference Area $99.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00F3010 Bulletin Board, 48" x 48" 1 $84.00 $84.00Secure Areas PHMP2 NR Prepackaging No Additional Schedule B ItemsSecure Areas SRR01 1 Refrigeration / Freezer Area $26,690.00L7100 Room, Controlled Environment 1 $26,690.00 $26,690.00Secure Areas PHOD2 1 Storage, Active $365.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00P-414 Lavatory, Vitreous China, withWrist Blade Faucet 1 $298.00 $298.00Secure Areas SSS01 1 Storage, Controlled Substance /Secured Dispensing $365.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00P-414 Lavatory, Vitreous China, withWrist Blade Faucet 1 $298.00 $298.00Secure Areas SRHM1 NR Storage, Flammable No Additional Schedule B ItemsSecure Areas SRCS1 NRStorage, Prosthetic and MedicalSuppliesSecure Areas TLTU1 1 Toilet, Staff $1,024.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5109 Grab Bars, SS, 1-1/2" Dia AR $175.00 $175.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00A5165 Shelf T-45, SS, 12"w x 5"d 1 $55.00 $55.00A5202 Dispenser, Toilet Paper w/UtilityShelf, SS, 2-Roll 1 $74.00 $74.00P-418 Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00P-103 Toilet, Wall Hung, w/seat 1 $265.00 $265.00No Additional Schedule B ItemsPhysical Medicine and Rehabiltation (PMR)Occupational Therapy (OT) OTGC1 NR Treatment Clinic No Additional Schedule B ItemsOccupational Therapy (OT) SRE01 NR Storage, Equipment No Additional Schedule B ItemsOccupational Therapy (OT) OFA02 1 Clinic <strong>Office</strong> $30.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Physical Therapy (PT) DR001 1 Dressing Room $336.00A1066 Mirror, SS Framed, 20x48 1 $95.00 $95.00A5021 Bench, Dressing, Wall Mounted 1 $211.00 $211.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Physical Therapy (PT) TLTU1 1 Toilet, Patient $1,024.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5109 Grab Bars, SS, 1-1/2" Dia AR $175.00 $175.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00A5165 Shelf T-45, SS, 12"w x 5"d 1 $55.00 $55.00A5202 Dispenser, Toilet Paper w/UtilityShelf, SS, 2-Roll 1 $74.00 $74.00P-418 Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00______Lessor Gov't_______Part III: Special Requirements -- Schedule B___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXDepartment / Functional AreaRoomCodeQty <strong>of</strong>Rooms FunctionSCHEDULE B--SPECIAL REQUIREMENTS: Functional Room ListEquipmentSymbol orJSN Code Item Description Qty Unit Cost Extension Subtotal NotesP-103 Toilet, Wall Hung, w/seat 1 $265.00 $265.00Physical Therapy (PT) SRE01 NR Storage, Equipment No Additional Schedule B ItemsPhysical Therapy (PT) PTEA1 1 Treatment Exercise Area $5,839.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00A1080 Mirror, Posture, Wall Mounted 1 $338.00 $338.00Dispenser, Paper Towel, SS,A5080 Surface Mounted 1 $67.00 $67.00M8075 Lift, Patient, Physical Therapy 1 $5,061.00 $5,061.00P-418 Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00Physical Therapy (PT) UTLC1 1 Utility Room, Clean $946.00CD040 Cabinet, Metal, Wall, T-5B, 2 Shelf,2 Doors, Sloping Top, 36x42x22 1 $946.00 $946.00PMR WRC01 1 Waiting Area $436.00Bracket, Television, Wall Mounted,A5210 Adjustable Arm 1 $296.00 $296.00F2310 Rack, Pamphlet, Wall Mounted 1 $140.00 $140.00Police and SecurityPolice and Security CROP1 NR Holding Room No Additional Schedule B ItemsPolice and Security OPMH4 1 Operations Room $30.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Prosthetics and Sensory AidsProsthetics and Sensory Aids OFA02 3 <strong>Office</strong> $90.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Prosthetics and Sensory Aids SEC01 1 <strong>Office</strong>, Secretary and Waiting $30.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Prosthetics and Sensory Aids SRCS1 NRProsthetics and Sensory Aids SRCS1 NRProsthetic Appliance Storage: MailingRoomProsthetic Appliance Storage:Storage RoomProsthetics and Sensory Aids RECP1 1 Reception and Waiting Area $2,812.00C0038 Rail, Apron, 4x42x1 1 $116.00 $116.00C0039 Rail, Apron, 4x48x1 1 $84.00 $84.00No Additional Schedule B ItemsNo Additional Schedule B ItemsC0045 Frame, Apron, 1 Drawer, 4x36x22 1 $420.00 $420.00C0046 Frame, Apron, 2 Drawer, 4x48x22 1 $629.00 $629.00C06M0CT030Cabinet, Under Counter, Pull-outBoard, 2 Drawer, 1 File Drawer,30x18x22 1 $863.00 $863.00Countertop, High PressureLaminate 10 $70.00 $700.00Pulmonary Medicine (PM)Pulmonary Medicine (PM) OPPF5 1 Exercise Room $413.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00A1080 Mirror, Posture, Wall Mounted 1 $338.00 $338.00Pulmonary Medicine (PM) TRPE2 1Special Procedures /Bronchoscopy Room $562.00______Lessor Gov't_______Part III: Special Requirements -- Schedule B___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]Department / Functional AreaRoomCodeQty <strong>of</strong>Rooms FunctionSCHEDULE B--SPECIAL REQUIREMENTS: Functional Room ListEquipmentSymbol orJSN Code Item Description Qty Unit Cost Extension Subtotal NotesA5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5180 Track, Cubicle Curtain, SurfaceMounted 12 $7.00 $84.00A5165 Shelf T-45, SS, 12"w x 5"d 1 $55.00 $55.00Lavatory, Vitreous China, withP-418 Sensor Faucet 1 $298.00 $298.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00M1620Holder, Chart, Patient, Wall orDoor Mounted 1 $28.00 $28.00Pulmonary Medicine (PM) OPPF1 1 Ventilatory Test Room, Spirometry $365.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00P-418 Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00RadiologyRadiology XDCS1 1 Chest Room - Dedicated $608.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00P-403 Lavatory, Vitreous China, with FootPedal Control 1 $355.00 $355.00X3150 Rack, Apron / Gloves, WallMounted 1 $171.00 $171.00Radiology XVC01 1 Common Viewing Room $580.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Radiology XCTS1 NRRadiology XCTC1 NRRadiology XCTS1 1Radiology SRE01 NRX3900 Illuminator, Film, Double,Recessed 1 $550.00 $550.00Computed Tomography: Computer /Power Equipment RoomComputed Tomography: ControlRoomComputed Tomography: ScanningRoom $6,547.00Dispenser, Paper Towel, SS,A5080 Surface Mounted 1 $67.00 $67.00Cabinet, Base, 2 Half-Drawer, 3C03H0 Door, 36x30x22 1 $1,498.00 $1,498.00Cabinet, Base, 8 Half-DrawerC03J0 36x30x22 1 $1,710.00 $1,710.00C03P0 Cabinet, Sink, 2 Door, 30" W 1 $915.00 $915.00Cabinet, Wall, 2 Shelf, GlassCE030 Doors, Sloping Top, 38x30x13 1 $789.00 $789.00Sink, SS, Single Compartment,CS140 10x14x16 ID 1 $837.00 $837.00Countertop, High PressureCT030 Laminate 8 $70.00 $560.00Rack, Apron / Gloves, WallX3150 Mounted 1 $171.00 $171.00Computed Tomography: StorageRoom______Lessor Gov't_______Part III: Special Requirements -- Schedule BMAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXNo Additional Schedule B ItemsNo Additional Schedule B ItemsNo Additional Schedule B Items___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]Department / Functional AreaRoomCodeRadiology TLTU1 1Qty <strong>of</strong>Rooms FunctionSCHEDULE B--SPECIAL REQUIREMENTS: Functional Room ListEquipmentSymbol orJSN Code Item Description Qty Unit Cost Extension Subtotal NotesComputed Tomography: Toilet,Patient $1,024.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5109 Grab Bars, SS, 1-1/2" Dia AR $175.00 $175.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00A5165 Shelf T-45, SS, 12"w x 5"d 1 $55.00 $55.00Dispenser, Toilet Paper w/UtilityA5202 Shelf, SS, 2-Roll 1 $74.00 $74.00P-103 Toilet, Wall Hung, w/seat 1 $265.00 $265.00P-418Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00Radiology DR001 7 Dressing Room $2,352.00A1066 Mirror, SS Framed, 20x48 1 $95.00 $95.00A5021 Bench, Dressing, Wall Mounted 1 $211.00 $211.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Radiology XDR01 1 General Purpose Radiology Room $2,333.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00P-403 Lavatory, Vitreous China, with FootPedal Control 1 $355.00 $355.00X3150 Rack, Apron / Gloves, WallMounted 1 $171.00 $171.00Outlets, Med Gas: O2, Air, Vaccum 3 $575.00 $1,725.00Radiology JANC1 1 Housekeeping Aids Closet - HAC $1,934.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5135 Rack, Mop, T-10, Wall Mounted 1 $211.00 $211.00CD045 Cabinet, SS, Wall, T-7, 2 Shelf, 2Doors, Sloping Top, 36x48x12 1 $1,242.00 $1,242.00P-502 Sink, Service, Corner, FloorMounted 1 $414.00 $414.00Radiology XDM01 1 Mammography Room $739.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00A5180 Track, Cubicle Curtain, SurfaceMounted 10 $7.00 $70.00M1620 Holder, Chart, Patient, Wall orDoor Mounted 1 $28.00 $28.00P-418 Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00X3150 Rack, Apron / Gloves, WallMounted 1 $171.00 $171.00Radiology OFDR1 1 <strong>Office</strong>, Chief Radiologist $30.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Radiology OFA02 5 <strong>Office</strong>, Pr<strong>of</strong>essional, Non Physician $150.00______Lessor Gov't_______Part III: Special Requirements -- Schedule BMAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXX___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]Department / Functional AreaRoomCodeQty <strong>of</strong>Rooms FunctionSCHEDULE B--SPECIAL REQUIREMENTS: Functional Room ListEquipmentSymbol orJSN Code Item Description Qty Unit Cost Extension Subtotal NotesA5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Radiology OFA03 1 <strong>Office</strong>, Reception $99.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00F3010 Bulletin Board, 48" x 48" 1 $84.00 $84.00Radiology SEC01 1 <strong>Office</strong>, Secretary and Waiting $30.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Radiology OFDR1 3 <strong>Office</strong>, Staff Radiologist $90.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Radiology XDRF1 1Radiographic / Fluoroscopic (R/F)Room $437.00Dispenser, Paper Towel, SS,A5080 Surface Mounted 1 $67.00 $67.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00P-403Lavatory, Vitreous China, with FootPedal Control 1 $355.00 $355.00Radiology TLTU1 1 Ultrasound: Toilet, Patient $1,024.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5109 Grab Bars, SS, 1-1/2" Dia AR $175.00 $175.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00A5165 Shelf T-45, SS, 12"w x 5"d 1 $55.00 $55.00A5202 Dispenser, Toilet Paper w/UtilityShelf, SS, 2-Roll 1 $74.00 $74.00P-418 Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00P-103 Toilet, Wall Hung, w/seat 1 $265.00 $265.00Radiology XDUS1 1 Ultrasound Room $4,136.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00A5180 Track, Cubicle Curtain, SurfaceMounted 10 $7.00 $70.00C03F0 Cabinet, Base, 1 Shelf, 2 Half-Drawer, 2 Door, 36x30x22 1 $1,024.00 $1,024.00C03P0 Cabinet, Sink, 2 Door, 30" W 1 $915.00 $915.00CE030 Cabinet, Wall, 2 Shelf, GlassDoors, Sloping Top, 38x30x13 1 $789.00 $789.00CS150 Sink, SS, Single Compartment,10x19x16 ID 1 $878.00 $878.00CT030 Countertop, High PressureLaminate 5 $70.00 $350.00M1620 Holder, Chart, Patient, Wall orDoor Mounted 1 $28.00 $28.00Radiology UCCL1 1 Utility Room, Clean $946.00CD040 Cabinet, Metal, Wall, T-5B, 2 Shelf,2 Doors, Sloping Top, 36x42x22 1 $946.00 $946.00Radiology USCL1 1 Utility Room, Soiled $894.00P-418 Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00P-505 Sink, Service, Clinical Flushing rim,Wall Hung 1 $596.00 $596.00______Lessor Gov't_______Part III: Special Requirements -- Schedule BMAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXX___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXRoomCodeQty <strong>of</strong>Rooms FunctionSCHEDULE B--SPECIAL REQUIREMENTS: Functional Room ListEquipmentSymbol orJSN Code Item Description Qty Unit Cost Extension Subtotal NotesDepartment / Functional AreaRadiology WRC01 1 Waiting Area $436.00Bracket, Television, Wall Mounted,A5210 Adjustable Arm 1 $296.00 $296.00F2310 Rack, Pamphlet, Wall Mounted 1 $140.00 $140.00Radiology SRLW1 NR Waiting, Wheelchair and Stretcher No Additional Schedule B ItemsService OrganizationsService Organizations SEC01 2 <strong>Office</strong>, Secretary $60.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Service Organizations OFA02 6<strong>Office</strong>, Service OrganizationRepresentative $180.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Service Organizations SRS01 NR Storage No Additional Schedule B ItemsSupply, Processing and Distribution (SPD)SPD: Clean OFA03 1 Dispatch Area $99.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00F3010 Bulletin Board, 48" x 48" 1 $84.00 $84.00SPD: Clean JANC1 1 Housekeeping Aids Closet (HAC) $1,934.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5135 Rack, Mop, T-10, Wall Mounted 1 $211.00 $211.00CD045 Cabinet, SS, Wall, T-7, 2 Shelf, 2Doors, Sloping Top, 36x48x12 1 $1,242.00 $1,242.00P-502 Sink, Service, Corner, FloorMounted 1 $414.00 $414.00SPD: Clean CSIA2 1 Preparation Area $15,106.00CW150 Cabinet, Floor Standing, 5 Shelf, 2Glass Doors, 98x48x22 5 $2,384.00 $11,920.00S9610 Station, Utility / Rack 1 $3,186.00 $3,186.00SPD: Clean ORSS1 NR Storage, Bulk and Receiving No Additional Schedule B ItemsStorage, Equipment and TestingSPD: Clean SRSE1 NR RoomNo Additional Schedule B ItemsSPD: Clean SRGC1 1 Storage, Ethylene Oxide GasCylinder $6,291.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00C02D0 Cabinet, Base, 4 Drawer,36x24x22 1 $1,087.00 $1,087.00C04P0 Cabinet,Sink, 2 Door, 36x36x22 1 $994.00 $994.00CS260 Sink, Epoxy Resin, 10x25x15 ID 1 $594.00 $594.00CT060 Countertop, Modified Epoxy Resin 6 $146.00 $876.00CW130 Cabinet, Floor Standing, 5 Shelf, 2Glass Doors, 98x30x22 1 $2,317.00 $2,317.00P1965 Eyewash, Eye/Face, Sink Mounted,Hands Free 1 $356.00 $356.00SPD: Clean ORSS1 NR Storage, Sterile / Nonsterile No Additional Schedule B ItemsSPD: Soiled JANC1 1 Housekeeping Aids Closet (HAC) $1,795.00Dispenser, Paper Towel, SS,A5080 Surface Mounted 1 $67.00 $67.00A5135 Rack, Mop, T-10, Wall Mounted 1 $211.00 $211.00______Lessor Gov't_______Part III: Special Requirements -- Schedule B___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]Department / Functional AreaRoomCodeSPD: Soiled TLTS1 1Qty <strong>of</strong>Rooms FunctionSCHEDULE B--SPECIAL REQUIREMENTS: Functional Room ListEquipmentSymbol orJSN Code Item Description Qty Unit Cost Extension Subtotal NotesCD045P-502Cabinet, SS, Wall, T-7, 2 Shelf, 2Doors, Sloping Top, 36x48x12 1 $1,242.00 $1,242.00Sink, Service, Corner, FloorMounted 1 $275.00 $275.00Lockers, Toilet and Shower<strong>Facilities</strong> $2,323.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00A5030 Bench, Shower, Built-in 1 $618.00 $618.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5090 Disposal, Sanitary Napkin, SS,Surface Mounted 1 $44.00 $44.00A5109 Grab Bars, SS, 1-1/2" Dia AR $175.00 $175.00A5110 Grab Bar, SS, 1-1/2" Dia, ShowerUse AR $175.00 $175.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00A5165 Shelf T-45, SS, 12"w x 5"d 1 $55.00 $55.00A5170 Rod, Shower curtain, 1"dia,w/curtain and hooks 1 $48.00 $48.00A5175 Soap Dish, SS, Recessed 1 $30.00 $30.00A5202 Dispenser, Toilet Paper w/UtilityShelf, SS, 2-Roll 1 $74.00 $74.00A5205 Bar, Towel, 1" dia, SS, SurfaceMounted 1 $40.00 $40.00P-103 Toilet, Wall Hung, w/seat 1 $265.00 $265.00P-418Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00P-703 Shower, Single, Hand Held 1 $344.00 $344.00SPD: Soiled CWSH1 1 Manual Equipment Wash $3,707.00S4300 Gun, Steam 1 $3,707.00 $3,707.00SPD: Soiled CSDE2 1Receiving and DecontaminationArea $15,649.00A1195A5080Counter, Cleanup, SS, with 2 or 3sinks 1 $11,800.00 $11,800.00Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00Sink, Service, Clinical Flushing rim,P-505 Wall Hung 1 $596.00 $596.00S9610 Station, Utility / Rack 1 $3,186.00 $3,186.00SurgerySurgery-Ambulatory Surgery OFD03 16 <strong>Office</strong> $480.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Surgery-Ambulatory Surgery OFA03 4 <strong>Office</strong>, Clerical $396.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00F3010 Bulletin Board, 48" x 48" 1 $84.00 $84.00Surgery-Ambulatory Surgery LR002 1 Changing Room, Patient $336.00A1066 Mirror, SS Framed, 20x48 1 $95.00 $95.00A5021 Bench, Dressing, Wall Mounted 1 $211.00 $211.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Surgery-Ambulatory Surgery ORCS1 1 Cystoscopic Room $44,681.00A1120Column, Service, Prefab, Surgical,Ceiling Mounted 1 $13,282.00 $13,282.00______Lessor Gov't_______Part III: Special Requirements -- Schedule BMAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXX___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]Department / Functional AreaRoomCodeSurgery-Ambulatory Surgery XDCY1 1Qty <strong>of</strong>Rooms FunctionSCHEDULE B--SPECIAL REQUIREMENTS: Functional Room ListEquipmentSymbol orJSN Code Item Description Qty Unit Cost Extension Subtotal NotesA1130 Cabinet, Control, Nitrogen 1 $954.00 $954.00A4015 Clock, Elapsed Time, Electric 1 $357.00 $357.00Cabinet, Floor Standing, 5 Shelf, 2Glass Doors, Sloping Top,CW199 48x84x22 1 $2,384.00 $2,384.00Light, Surgical, Ceiling Mounted,M7490 Dual unequal dia Heads 1 $26,177.00 $26,177.00Rack, Apron / Gloves, WallX3150 Mounted 1 $171.00 $171.00X4000 Illuminator, 4 Panel, Recessed 1 $1,356.00 $1,356.00Cystoscopy: External RadiographicControl Room $2,920.00C0044 Frame, Apron, 1 Drawer, 4x30x22 1 $300.00 $300.00C0045 Frame, Apron, 1 Drawer, 4x36x22 1 $420.00 $420.00C06M0Cabinet, Under Counter, Pull-outBoard, 2 Drawer, 1 File Drawer,30x18x22 1 $863.00 $863.00Countertop, High PressureCT030 Laminate 6 $70.00 $420.00F3050 Whiteboard, Dry Erase 1 $196.00 $196.00Rack, Apron / Gloves, WallX3150 Mounted 1 $171.00 $171.00Illuminator, Film, Double,X3900 Recessed 1 $550.00 $550.00Surgery-Ambulatory Surgery JANC1 1 Housekeeping Aids Closet (HAC) $1,934.00Surgery-Ambulatory Surgery OREC1 1A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5135 Rack, Mop, T-10, Wall Mounted 1 $211.00 $211.00CD045 Cabinet, SS, Wall, T-7, 2 Shelf, 2Doors, Sloping Top, 36x48x12 1 $1,242.00 $1,242.00P-502 Sink, Service, Corner, FloorMounted 1 $414.00 $414.00Cystoscopy: InstrumentPreparation and Storage Room $4,863.00A5080Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00Cabinet, Base, 1 Shelf, 1 Drawer, 1C02C0 Door, 36x24x22 1 $898.00 $898.00C05P0 Cabinet,Sink, 2 Door, 36x48x22 1 $1,052.00 $1,052.00CS200Sink, SS, Single Compartment,12x28x16 ID 1 $1,228.00 $1,228.00CT039 Countertop, Solid Surface Material 7 $146.00 $1,022.00P-505Sink, Service, Clinical Flushing rim,Wall Hung 1 $596.00 $596.00Surgery-Ambulatory Surgery ORSA1 1 Cystoscopy: Scrub-up area $25,532.00P6980 Sink, Scrub, SS, w/knee control 2 $12,766.00 $25,532.00Surgery-Ambulatory Surgery RRSS1 1 Lounge, Postoperative Recovery $11,723.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00A1107Rail System, Utility, Gas andElectric 1 $7,421.00 $7,421.00______Lessor Gov't_______Part III: Special Requirements -- Schedule BMAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXX___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXDepartment / Functional AreaRoomCodeQty <strong>of</strong>Rooms FunctionSCHEDULE B--SPECIAL REQUIREMENTS: Functional Room ListEquipmentSymbol orJSN Code Item Description Qty Unit Cost Extension Subtotal NotesA1165 Track, IV, Ceiling Mounted, 2x 7foot 14 $56.00 $784.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00Track, Cubicle Curtain, SurfaceA5180 Mounted 22 $7.00 $154.00M7405 Light, Exam, Ceiling Mounted 1 $2,348.00 $2,348.00M7425 Light, Overbed, Direct and Indirect 1 $561.00 $561.00P-414 Lavatory, Vitreous China, withWrist Blade Faucet 1 $298.00 $298.00Surgery-Ambulatory Surgery NSTA1 1 Nurse Station $7,911.00C0045 Frame, Apron, 1 Drawer, 4x36x22 1 $420.00 $420.00Surgery-Ambulatory Surgery ANCW1 1C0046 Frame, Apron, 2 Drawer, 4x48x22 1 $629.00 $629.00C06M0C09F0C09G0CG040CG050Cabinet, Under Counter, Pull-outBoard, 2 Drawer, 1 File Drawer,30x18x22 1 $863.00 $863.00Cabinet, Under Counter, 2 Half-Drawer, 2 Door, 30" W 1 $1,175.00 $1,175.00Cabinet, Under Counter, 1 Shelf, 2Door, 30x36x22 1 $930.00 $930.00Cabinet, Wall, 2 Shelf, SlidingGlass Door, Sloping Top,38x36x13 1 $1,291.00 $1,291.00Cabinet, Wall, 2 Shelf, SlidingGlass Door, Sloping Top,38x48x13 1 $1,427.00 $1,427.00Countertop, High PressureCT030 Laminate 14 $70.00 $980.00F3050 Whiteboard, Dry Erase 1 $196.00 $196.00OR: Anesthesia, Workroom andEquip. Storage $16,051.00A1107A5080C04E0Rail System, Utility, Gas andElectric 1 $7,421.00 $7,421.00Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00Cabinet, Base, 1 Shelf, 1 Drawer, 2Door, 36x36x22 1 $1,207.00 $1,207.00Cabinet, Base, 8 Half Drawer,C04J0 36x36x22 1 $1,752.00 $1,752.00C04P0 Cabinet,Sink, 2 Door, 36x36x22 1 $994.00 $994.00Sink, SS, Single Compartment,CS200 12x28x16 ID 1 $1,228.00 $1,228.00Countertop, SS, w/IntegralCT050 Backsplash 6 $531.00 $3,186.00F3050 Whiteboard, Dry Erase 1 $196.00 $196.00Surgery-Ambulatory Surgery ORCW1 NR OR: Clean Core-Staff Workroom No Additional Schedule B ItemsSurgery-Ambulatory Surgery NSTA4 1OR: Control and CommunicationCenter $7,911.00______Lessor Gov't_______Part III: Special Requirements -- Schedule B___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]Department / Functional AreaRoomCodeQty <strong>of</strong>Rooms FunctionSCHEDULE B--SPECIAL REQUIREMENTS: Functional Room ListEquipmentSymbol orJSN Code Item Description Qty Unit Cost Extension Subtotal NotesC0045 Frame, Apron, 1 Drawer, 4x36x22 1 $420.00 $420.00C0046 Frame, Apron, 2 Drawer, 4x48x22 1 $629.00 $629.00C06M0C09F0C09G0CG040CG050Cabinet, Under Counter, Pull-outBoard, 2 Drawer, 1 File Drawer,30x18x22 1 $863.00 $863.00Cabinet, Under Counter, 2 Half-Drawer, 2 Door, 30" W 1 $1,175.00 $1,175.00Cabinet, Under Counter, 1 Shelf, 2Door, 30x36x22 1 $930.00 $930.00Cabinet, Wall, 2 Shelf, SlidingGlass Door, Sloping Top,38x36x13 1 $1,291.00 $1,291.00Cabinet, Wall, 2 Shelf, SlidingGlass Door, Sloping Top,38x48x13 1 $1,427.00 $1,427.00Countertop, High PressureCT030 Laminate 14 $70.00 $980.00F3050 Whiteboard, Dry Erase 1 $196.00 $196.00Surgery-Ambulatory Surgery OFA03 1 OR: Cubicle, Dictation $99.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00F3010 Bulletin Board, 48" x 48" 1 $84.00 $84.00Surgery-Ambulatory Surgery ORGS1 2 OR: General Operating Room (OR) $162,460.00A1120 Column, Service, Prefab, Surgical,Ceiling Mounted 2 $13,282.00 $26,564.00A1130 Cabinet, Control, Nitrogen 1 $954.00 $954.00A4015 Clock, Elapsed Time, Electric 1 $357.00 $357.00F3050 Whiteboard, Dry Erase 1 $196.00 $196.00M7485Light, Surgical, Ceiling Mounted,Dual equal dia Heads 1 $25,626.00 $25,626.00Light, Surgical, Ceiling Mounted,M7490 Dual unequal dia Heads 1 $26,177.00 $26,177.00X4000 Illuminator, 4 Panel, Recessed 1 $1,356.00 $1,356.00Surgery-Ambulatory Surgery ORPH2 3 OR: Holding Area, Patient $24,198.00Rail System, Utility, Gas andA1107 Electric 1 $7,421.00 $7,421.00Track, Cubicle Curtain, SurfaceA5180 Mounted 12 $7.00 $84.00M7425 Light, Overbed, Direct and Indirect 1 $561.00 $561.00Surgery-Ambulatory Surgery JANC1 2 OR: Housekeeping Aids Closet(HAC) $3,868.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5135 Rack, Mop, T-10, Wall Mounted 1 $211.00 $211.00CD045 Cabinet, SS, Wall, T-7, 2 Shelf, 2Doors, Sloping Top, 36x48x12 1 $1,242.00 $1,242.00P-502 Sink, Service, Corner, FloorMounted 1 $414.00 $414.00Surgery-Ambulatory Surgery LBBP1 1 OR: Laboratory, Frozen Section $2,756.00______Lessor Gov't_______Part III: Special Requirements -- Schedule BMAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXX___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]Department / Functional AreaRoomCodeQty <strong>of</strong>Rooms FunctionSCHEDULE B--SPECIAL REQUIREMENTS: Functional Room ListEquipmentSymbol orJSN Code Item Description Qty Unit Cost Extension Subtotal NotesA5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00P1965 Eyewash, Eye/Face, Sink Mounted,Hands Free 1 $356.00 $356.00P2450 Valve, Mixing, Thermostatic 1 $2,035.00 $2,035.00P-414Lavatory, Vitreous China, withWrist Blade Faucet 1 $298.00 $298.00Surgery-Ambulatory Surgery LR002 1 OR: Locker Room, Female Staff $797.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00A1080 Mirror, Posture, Wall Mounted 1 $338.00 $338.00A5020 Bench, Locker, Floor Mounted 1 $244.00 $244.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00A5165 Shelf T-45, SS, 12"w x 5"d 1 $55.00 $55.00A5180 Track, Cubicle Curtain, SurfaceMounted 10 $7.00 $70.00Surgery-Ambulatory Surgery LR002 1 OR: Locker Room, Male Staff $797.00Surgery-Ambulatory Surgery SL001 1Surgery-Ambulatory Surgery SL001 1A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00A1080 Mirror, Posture, Wall Mounted 1 $338.00 $338.00A5020 Bench, Locker, Floor Mounted 1 $244.00 $244.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00A5165 Shelf T-45, SS, 12"w x 5"d 1 $55.00 $55.00A5180Track, Cubicle Curtain, SurfaceMounted 10 $7.00 $70.00OR: Lounge, Nurses and other ORStaff $4,274.00A5080A5210Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00Bracket, Television, Wall Mounted,Adjustable Arm 1 $296.00 $296.00Cabinet, Base, 1 Shelf, 2 HalfC04F0 Drawer, 2 Door, 36x36x22 1 $1,100.00 $1,100.00C04P0 Cabinet,Sink, 2 Door, 36x36x22 1 $994.00 $994.00Sink, SS, Single Compartment,CS140 10x14x16 ID 1 $837.00 $837.00Countertop, High PressureCT030 Laminate 10 $70.00 $700.00F3010 Bulletin Board, 48" x 48" 1 $84.00 $84.00F3050 Whiteboard, Dry Erase 1 $196.00 $196.00OR: Lounge, Surgeons, Residentsand Students $4,274.00A5080A5210Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00Bracket, Television, Wall Mounted,Adjustable Arm 1 $296.00 $296.00Cabinet, Base, 1 Shelf, 2 HalfC04F0 Drawer, 2 Door, 36x36x22 1 $1,100.00 $1,100.00C04P0 Cabinet,Sink, 2 Door, 36x36x22 1 $994.00 $994.00Sink, SS, Single Compartment,CS140 10x14x16 ID 1 $837.00 $837.00Countertop, High PressureCT030 Laminate 10 $70.00 $700.00F3010 Bulletin Board, 48" x 48" 1 $84.00 $84.00F3050 Whiteboard, Dry Erase 1 $196.00 $196.00______Lessor Gov't_______Part III: Special Requirements -- Schedule BMAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXX___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXDepartment / Functional AreaRoomCodeQty <strong>of</strong>Rooms FunctionSCHEDULE B--SPECIAL REQUIREMENTS: Functional Room ListEquipmentSymbol orJSN Code Item Description Qty Unit Cost Extension Subtotal NotesSurgery-Ambulatory Surgery OFD03 1 OR: <strong>Office</strong>, Head Nurse $30.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Surgery-Ambulatory Surgery ORSA1 1 OR: Scrub-up Area $25,532.00P6980 Sink, Scrub, SS, 2 Bay, w/kneecontrol 2 $12,766.00 $25,532.00Surgery-Ambulatory Surgery USCL1 1 OR: Soiled Holding / DisposalRoom $894.00P-418 Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00P-505 Sink, Service, Clinical Flushing rim,Wall Hung 1 $596.00 $596.00Surgery-Ambulatory Surgery SRGC1 1 OR: Storage, Gas Cylinder Room $6,937.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00C02D0 Cabinet, Base, 4 Drawer,36x24x22 1 $1,087.00 $1,087.00C04P0 Cabinet,Sink, 2 Door, 36x36x22 1 $994.00 $994.00Cabinet, Wall, Open, 2 Shelf,CA040 Sloping Top, 36x38x13 1 $646.00 $646.00CS260 Sink, Epoxy Resin, 10x25x15 ID 1 $594.00 $594.00Surgery-Ambulatory Surgery UCCL1 1CT060 Countertop, Modified Epoxy Resin 6 $146.00 $876.00CW130 Cabinet, Floor Standing, 5 Shelf, 2Glass Doors, 98x30x22 1 $2,317.00 $2,317.00P1965 Eyewash, Eye/Face, Sink Mounted,Hands Free 1 $356.00 $356.00OR: Storage, Clean and SterileSupplies $946.00Surgery-Ambulatory Surgery SRE01 NROR: Storage, Equipment andApparatusCD040Cabinet, Metal, Wall, T-5B, 2 Shelf,2 Doors, Sloping Top, 36x42x22 1 $946.00 $946.00No Additional Schedule B ItemsSurgery-Ambulatory Surgery SRLW1 NR OR: Storage, Gurney No Additional Schedule B ItemsSurgery-Ambulatory Surgery ORSR1 1 OR: Substerile Room $56,570.00Surgery-Ambulatory Surgery TLTF2 1A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00C03P0 Cabinet, Sink, 2 Door, 30" W 1 $915.00 $915.00C04E0 Cabinet, Base, 1 Shelf, 1 Drawer, 2Door, 36x36x22 1 $1,207.00 $1,207.00CA020 Cabinet, Wall, Open, 2 Shelf,Sloping Top, 24x30x13 1 $581.00 $581.00CS150 Sink, SS, Single Compartment,10x19x16 ID 1 $878.00 $878.00CT050 Countertop, SS, w/IntegralBacksplash 6 $531.00 $3,186.00S0125Sterilizer, Electric, Vacuum, 1Door, Cabinet enclosed, 16x16x26chamber 1 $49,736.00 $49,736.00OR: Toilet / Shower Room, FemaleStaff $2,323.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00A5030 Bench, Shower, Built-in 1 $618.00 $618.00______Lessor Gov't_______Part III: Special Requirements -- Schedule B___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]Department / Functional AreaRoomCodeSurgery-Ambulatory Surgery TLTM2 1Surgery-Ambulatory Surgery MEDP1 1Qty <strong>of</strong>Rooms FunctionSCHEDULE B--SPECIAL REQUIREMENTS: Functional Room ListEquipmentSymbol orJSN Code Item Description Qty Unit Cost Extension Subtotal NotesA5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5090 Disposal, Sanitary Napkin, SS,Surface Mounted 1 $44.00 $44.00A5109 Grab Bars, SS, 1-1/2" Dia AR $175.00 $175.00A5110 Grab Bar, SS, 1-1/2" Dia, ShowerUse AR $175.00 $175.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00A5165 Shelf T-45, SS, 12"w x 5"d 1 $55.00 $55.00A5170 Rod, Shower curtain, 1"dia,w/curtain and hooks 1 $48.00 $48.00A5175 Soap Dish, SS, Recessed 1 $30.00 $30.00A5202 Dispenser, Toilet Paper w/UtilityShelf, SS, 2-Roll 1 $74.00 $74.00A5205 Bar, Towel, 1" dia, SS, SurfaceMounted 1 $40.00 $40.00P-103 Toilet, Wall Hung, w/seat 1 $265.00 $265.00Lavatory, Vitreous China, withP-418 Sensor Faucet 1 $298.00 $298.00P-703 Shower, Single, Hand Held 1 $344.00 $344.00OR: Toilet / Shower Room, MaleStaff $2,279.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00A5030 Bench, Shower, Built-in 1 $618.00 $618.00Dispenser, Paper Towel, SS,A5080 Surface Mounted 1 $67.00 $67.00A5109 Grab Bars, SS, 1-1/2" Dia AR $175.00 $175.00A5110 Grab Bar, SS, 1-1/2" Dia, ShowerUse AR $175.00 $175.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00A5165 Shelf T-45, SS, 12"w x 5"d 1 $55.00 $55.00A5170 Rod, Shower curtain, 1"dia,w/curtain and hooks 1 $48.00 $48.00A5175 Soap Dish, SS, Recessed 1 $30.00 $30.00A5202 Dispenser, Toilet Paper w/UtilityShelf, SS, 2-Roll 1 $74.00 $74.00A5205 Bar, Towel, 1" dia, SS, SurfaceMounted 1 $40.00 $40.00P-103 Toilet, Wall Hung, w/seat 1 $265.00 $265.00Lavatory, Vitreous China, withP-418 Sensor Faucet 1 $298.00 $298.00P-703 Shower, Single, Hand Held 1 $344.00 $344.00Postanesthesia Recovery (PAR):Medication Preparation Room $7,673.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00C04P0 Cabinet,Sink, 2 Door, 36x36x22 1 $994.00 $994.00C02D0 Cabinet, Base, 4 Drawer,36x24x22 1 $1,087.00 $1,087.00CT050 Countertop, SS, w/IntegralBacksplash 6 $531.00 $3,186.00CS090 Sink, SS, Single Compartment,Intergal w/ SS Top, 7.5x19x16 ID 1 $912.00 $912.00______Lessor Gov't_______Part III: Special Requirements -- Schedule BMAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXX___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]Department / Functional AreaRoomCodeSurgery-Ambulatory Surgery NSTA4 1Qty <strong>of</strong>Rooms FunctionSCHEDULE B--SPECIAL REQUIREMENTS: Functional Room ListEquipmentSymbol orJSN Code Item Description Qty Unit Cost Extension Subtotal NotesCG050Cabinet, Wall, 2 Shelf, SlidingGlass Door, Sloping Top,38x48x13 1 $1,427.00 $1,427.00Postanesthesia Recovery (PAR):Nurse Station $7,911.00C0045 Frame, Apron, 1 Drawer, 4x36x22 1 $420.00 $420.00Surgery-Ambulatory Surgery RROP1 6C0046 Frame, Apron, 2 Drawer, 4x48x22 1 $629.00 $629.00C06M0C09F0C09G0CG040CG050Cabinet, Under Counter, Pull-outBoard, 2 Drawer, 1 File Drawer,30x18x22 1 $863.00 $863.00Cabinet, Under Counter, 2 Half-Drawer, 2 Door, 30" W 1 $1,175.00 $1,175.00Cabinet, Under Counter, 1 Shelf, 2Door, 30x36x22 1 $930.00 $930.00Cabinet, Wall, 2 Shelf, SlidingGlass Door, Sloping Top,38x36x13 1 $1,291.00 $1,291.00Cabinet, Wall, 2 Shelf, SlidingGlass Door, Sloping Top,38x48x13 1 $1,427.00 $1,427.00Countertop, High PressureCT030 Laminate 14 $70.00 $980.00F3050 Whiteboard, Dry Erase 1 $196.00 $196.00Postanesthesia Recovery (PAR):Recovery Bed $43,692.00A1110 PBPU, Headwall, Prefabricated 1 $5,054.00 $5,054.00A1165 Track, IV, Ceiling Mounted, 4x 7foot 28 $56.00 $1,568.00A5180 Track, Cubicle Curtain, SurfaceMounted 12 $7.00 $84.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00Surgery-Ambulatory Surgery SRS01 NRSurgery-Ambulatory Surgery TLTU1 1Postanesthesia Recovery (PAR):StoragePostanesthesia Recovery (PAR):M7425 Light, Overbed, Direct and Indirect 1 $561.00 $561.00Toilet, Staff $1,024.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5109 Grab Bars, SS, 1-1/2" Dia AR $175.00 $175.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00A5165 Shelf T-45, SS, 12"w x 5"d 1 $55.00 $55.00A5202 Dispenser, Toilet Paper w/UtilityShelf, SS, 2-Roll 1 $74.00 $74.00P-418 Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00P-103 Toilet, Wall Hung, w/seat 1 $265.00 $265.00Surgery-Ambulatory Surgery UCCL1 1Postanesthesia Recovery (PAR):Utility Room, Clean $946.00______Lessor Gov't_______Part III: Special Requirements -- Schedule BMAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXNo Additional Schedule B Items___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXDepartment / Functional AreaRoomCodeQty <strong>of</strong>Rooms FunctionSCHEDULE B--SPECIAL REQUIREMENTS: Functional Room ListEquipmentSymbol orJSN Code Item Description Qty Unit Cost Extension Subtotal NotesSurgery-Ambulatory Surgery USCL1CD040Cabinet, Metal, Wall, T-5B, 2 Shelf,2 Doors, Sloping Top, 36x42x22 1 $946.00 $946.00Postanesthesia Recovery (PAR):Utility Room, Soiled $0.00P-418P-505Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00Sink, Service, Clinical Flushing rim,Wall Hung 1 $596.00 $596.00Surgery-Ambulatory Surgery RECP1 1 Reception $2,812.00C0038 Rail, Apron, 4x42x1 1 $116.00 $116.00C0039 Rail, Apron, 4x48x1 1 $84.00 $84.00C0045 Frame, Apron, 1 Drawer, 4x36x22 1 $420.00 $420.00C0046 Frame, Apron, 2 Drawer, 4x48x22 1 $629.00 $629.00C06M0CT030Cabinet, Under Counter, Pull-outBoard, 2 Drawer, 1 File Drawer,30x18x22 1 $863.00 $863.00Countertop, High PressureLaminate 10 $70.00 $700.00Surgery-Ambulatory Surgery RCA01 NR Storage, Crash Cart No Additional Schedule B ItemsSurgery-Ambulatory Surgery TLTU1 2 Toilet, Patient $2,048.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5109 Grab Bars, SS, 1-1/2" Dia AR $175.00 $175.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00A5165 Shelf T-45, SS, 12"w x 5"d 1 $55.00 $55.00A5202 Dispenser, Toilet Paper w/UtilityShelf, SS, 2-Roll 1 $74.00 $74.00P-418 Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00P-103 Toilet, Wall Hung, w/seat 1 $265.00 $265.00Surgery-Ambulatory Surgery WRF01 1 Waiting, Patient / Family $436.00Bracket, Television, Wall Mounted,A5210 Adjustable Arm 1 $296.00 $296.00F2310 Rack, Pamphlet, Wall Mounted 1 $140.00 $140.00Surgery-Minor Surgery DR001 1 Changing Room, Patient $336.00A1066 Mirror, SS Framed, 20x48 1 $95.00 $95.00A5021 Bench, Dressing, Wall Mounted 1 $211.00 $211.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Surgery-Minor Surgery NSTA1 1 Control and Communication Center $7,911.00C0045 Frame, Apron, 1 Drawer, 4x36x22 1 $420.00 $420.00C0046 Frame, Apron, 2 Drawer, 4x48x22 1 $629.00 $629.00C06M0C09F0Cabinet, Under Counter, Pull-outBoard, 2 Drawer, 1 File Drawer,30x18x22 1 $863.00 $863.00Cabinet, Under Counter, 2 Half-Drawer, 2 Door, 30" W 1 $1,175.00 $1,175.00______Lessor Gov't_______Part III: Special Requirements -- Schedule B___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]Department / Functional AreaRoomCodeQty <strong>of</strong>Rooms FunctionSCHEDULE B--SPECIAL REQUIREMENTS: Functional Room ListEquipmentSymbol orJSN Code Item Description Qty Unit Cost Extension Subtotal NotesC09G0CG040CG050Cabinet, Under Counter, 1 Shelf, 2Door, 30x36x22 1 $930.00 $930.00Cabinet, Wall, 2 Shelf, SlidingGlass Door, Sloping Top,38x36x13 1 $1,291.00 $1,291.00Cabinet, Wall, 2 Shelf, SlidingGlass Door, Sloping Top,38x48x13 1 $1,427.00 $1,427.00Countertop, High PressureCT030 Laminate 14 $70.00 $980.00F3050 Whiteboard, Dry Erase 1 $196.00 $196.00Surgery-Minor Surgery ORPH2 1 Holding Area, Patient $8,431.00Rail System, Utility, Gas andA1107 Electric 1 $7,421.00 $7,421.00Dispenser, Paper Towel, SS,A5080 Surface Mounted 1 $67.00 $67.00Track, Cubicle Curtain, SurfaceA5180 Mounted 12 $7.00 $84.00M7425 Light, Overbed, Direct and Indirect 1 $561.00 $561.00P-418 Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00Surgery-Minor Surgery JANC1 1 Housekeeping Aids Closet $1,934.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5135 Rack, Mop, T-10, Wall Mounted 1 $211.00 $211.00CD045 Cabinet, SS, Wall, T-7, 2 Shelf, 2Doors, Sloping Top, 36x48x12 1 $1,242.00 $1,242.00P-502 Sink, Service, Corner, FloorMounted 1 $414.00 $414.00Surgery-Minor Surgery LR002 1 Locker Room, Female Staff $797.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00A1080 Mirror, Posture, Wall Mounted 1 $338.00 $338.00A5020 Bench, Locker, Floor Mounted 1 $244.00 $244.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00A5165 Shelf T-45, SS, 12"w x 5"d 1 $55.00 $55.00A5180 Track, Cubicle Curtain, SurfaceMounted 10 $7.00 $70.00Surgery-Minor Surgery LR002 1 Locker Room, Male Staff $797.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00A1080 Mirror, Posture, Wall Mounted 1 $338.00 $338.00A5020 Bench, Locker, Floor Mounted 1 $244.00 $244.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00A5165 Shelf T-45, SS, 12"w x 5"d 1 $55.00 $55.00A5180Track, Cubicle Curtain, SurfaceMounted 10 $7.00 $70.00Surgery-Minor Surgery RRSS1 1 Lounge, Postoperative Recovery $11,723.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00A1107A1165Rail System, Utility, Gas andElectric 1 $7,421.00 $7,421.00Track, IV, Ceiling Mounted, 2x 7foot 14 $56.00 $784.00______Lessor Gov't_______Part III: Special Requirements -- Schedule BMAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXX___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]Department / Functional AreaRoomCodeQty <strong>of</strong>Rooms FunctionSCHEDULE B--SPECIAL REQUIREMENTS: Functional Room ListEquipmentSymbol orJSN Code Item Description Qty Unit Cost Extension Subtotal NotesDispenser, Paper Towel, SS,A5080 Surface Mounted 1 $67.00 $67.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00Track, Cubicle Curtain, SurfaceA5180 Mounted 22 $7.00 $154.00M7405 Light, Exam, Ceiling Mounted 1 $2,348.00 $2,348.00Surgery-Minor Surgery TRGS1 2M7425 Light, Overbed, Direct and Indirect 1 $561.00 $561.00P-414Lavatory, Vitreous China, withWrist Blade Faucet 1 $298.00 $298.00Minor Procedure / Operating Room(OR) $9,482.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00A5180Track, Cubicle Curtain, SurfaceMounted 14 $7.00 $98.00Cabinet, Base, 1 Shelf, 2 Half-C03F0 Drawer, 2 Door, 36x30x22 1 $1,024.00 $1,024.00C03P0 Cabinet, Sink, 2 Door, 30" W 1 $915.00 $915.00Cabinet, Wall, 2 Shelf, GlassCE030 Doors, Sloping Top, 38x30x13 1 $789.00 $789.00Sink, SS, Single Compartment,CS150 10x19x16 ID 1 $878.00 $878.00CT039 Countertop, Solid Surface Material 7 $146.00 $1,022.00Surgery-Minor Surgery NSTA1 1 Nurse Station $7,911.00C0045 Frame, Apron, 1 Drawer, 4x36x22 1 $420.00 $420.00C0046 Frame, Apron, 2 Drawer, 4x48x22 1 $629.00 $629.00C06M0C09F0C09G0CG040CG050Cabinet, Under Counter, Pull-outBoard, 2 Drawer, 1 File Drawer,30x18x22 1 $863.00 $863.00Cabinet, Under Counter, 2 Half-Drawer, 2 Door, 30" W 1 $1,175.00 $1,175.00Cabinet, Under Counter, 1 Shelf, 2Door, 30x36x22 1 $930.00 $930.00Cabinet, Wall, 2 Shelf, SlidingGlass Door, Sloping Top,38x36x13 1 $1,291.00 $1,291.00Cabinet, Wall, 2 Shelf, SlidingGlass Door, Sloping Top,38x48x13 1 $1,427.00 $1,427.00Countertop, High PressureCT030 Laminate 14 $70.00 $980.00F3050 Whiteboard, Dry Erase 1 $196.00 $196.00Surgery-Minor Surgery OFA02 1 <strong>Office</strong>, Head Nurse $30.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Surgery-Minor Surgery RECP1 1 Reception $2,812.00C0038 Rail, Apron, 4x42x1 1 $116.00 $116.00C0039 Rail, Apron, 4x48x1 1 $84.00 $84.00C0045 Frame, Apron, 1 Drawer, 4x36x22 1 $420.00 $420.00______Lessor Gov't_______Part III: Special Requirements -- Schedule BMAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXX___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXDepartment / Functional AreaRoomCodeQty <strong>of</strong>Rooms FunctionSCHEDULE B--SPECIAL REQUIREMENTS: Functional Room ListEquipmentSymbol orJSN Code Item Description Qty Unit Cost Extension Subtotal NotesC0046 Frame, Apron, 2 Drawer, 4x48x22 1 $629.00 $629.00Cabinet, Under Counter, Pull-outBoard, 2 Drawer, 1 File Drawer,C06M0 30x18x22 1 $863.00 $863.00Countertop, High PressureCT030 Laminate 10 $70.00 $700.00Surgery-Minor Surgery ORSA1 1 Scrub Room / Sterilizer Area $25,532.00P6980 Sink, Scrub, SS, 2 Bay, w/kneecontrol 2 $12,766.00 $25,532.00Surgery-Minor Surgery USCL1 1 Soiled Holding / Disposal Room $894.00P-418 Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00P-505 Sink, Service, Clinical Flushing rim,Wall Hung 1 $596.00 $596.00Surgery-Minor Surgery SRGC1 1 Storage, Gas Cylinder Room $6,937.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00C02D0 Cabinet, Base, 4 Drawer,36x24x22 1 $1,087.00 $1,087.00C04P0 Cabinet,Sink, 2 Door, 36x36x22 1 $994.00 $994.00Cabinet, Wall, Open, 2 Shelf,CA040 Sloping Top, 36x38x13 1 $646.00 $646.00CS260 Sink, Epoxy Resin, 10x25x15 ID 1 $594.00 $594.00CT060 Countertop, Modified Epoxy Resin 6 $146.00 $876.00CW130 Cabinet, Floor Standing, 5 Shelf, 2Glass Doors, 98x30x22 1 $2,317.00 $2,317.00P1965 Eyewash, Eye/Face, Sink Mounted,Hands Free 1 $356.00 $356.00Surgery-Minor Surgery UCCL1 1 Storage, Clean And Sterile Supplies $946.00CD040Cabinet, Metal, Wall, T-5B, 2 Shelf,2 Doors, Sloping Top, 36x42x22 1 $946.00 $946.00Surgery-Minor Surgery RCA01 NR Storage, Crash Cart No Additional Schedule B ItemsSurgery-Minor Surgery SRE01 NR Storage, Equipment and Apparatus No Additional Schedule B ItemsSurgery-Minor Surgery SRLW1 NR Storage, Gurney No Additional Schedule B ItemsSurgery-Minor Surgery TLTU1 4 Toilet $4,096.00A1066 Mirror, SS Framed, 24x36 1 $75.00 $75.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5109 Grab Bars, SS, 1-1/2" Dia AR $175.00 $175.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00A5165 Shelf T-45, SS, 12"w x 5"d 1 $55.00 $55.00A5202 Dispenser, Toilet Paper w/UtilityShelf, SS, 2-Roll 1 $74.00 $74.00P-418 Lavatory, Vitreous China, withSensor Faucet 1 $298.00 $298.00P-103 Toilet, Wall Hung, w/seat 1 $265.00 $265.00Surgery-Minor Surgery WRF01 1 Waiting, Patient and Family $436.00______Lessor Gov't_______Part III: Special Requirements -- Schedule B___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXDepartment / Functional AreaRoomCodeQty <strong>of</strong>Rooms FunctionSCHEDULE B--SPECIAL REQUIREMENTS: Functional Room ListEquipmentSymbol orJSN Code Item Description Qty Unit Cost Extension Subtotal NotesBracket, Television, Wall Mounted,A5210 Adjustable Arm 1 $296.00 $296.00F2310 Rack, Pamphlet, Wall Mounted 1 $140.00 $140.00Voluntary ServiceVoluntary Service OFA01 1 <strong>Office</strong>, Chief $99.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00F3010 Bulletin Board, 48" x 48" 1 $84.00 $84.00Voluntary Service OFA03 5 <strong>Office</strong> / Workstation $495.00A5145 Coat Hook, SS, Surface Mounted 1 $15.00 $15.00F3010 Bulletin Board, 48" x 48" 1 $84.00 $84.00Voluntary Service SEC01 1 <strong>Office</strong>, Secretary $30.00A5145 Coat Hook, SS, Surface Mounted 2 $15.00 $30.00Voluntary Service SRS01 NR Storage No Additional Schedule B ItemsVoluntary Service WRCH1 1 Volunteer Multipurpose Room $4,218.00A5080 Dispenser, Paper Towel, SS,Surface Mounted 1 $67.00 $67.00A5210 Bracket, Television, Wall Mounted,Adjustable Arm 1 $296.00 $296.00C02B0 Cabinet, Base, 2 Shelf, 1 Door,36x24x22 1 $883.00 $883.00C04P0 Cabinet,Sink, 2 Door, 36x36x22 1 $994.00 $994.00CA040 Cabinet, Wall, Open, 2 Shelf,Sloping Top, 36x38x13 1 $646.00 $646.00CS090 Sink, SS, Single Compartment,7.5x19x16 ID 1 $912.00 $912.00CT030 Countertop, High PressureLaminate 6 $70.00 $420.00______Lessor Gov't_______Part III: Special Requirements -- Schedule B___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERSOUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXPART III: SCHEDULE B--SPECIAL REQUIREMENTS (cont.)SECTION 5--SUMMARY PRICE SHEETSPECIAL ITEMS FOR THE ENTIRE CLINICPublic Address SystemQty Unit Unit Cost Cost TotalCentral Equipment 1 ls $1.00 $1.00Speakers 115 ea $1.00 $115.00Audio Visual, Nurse Call and Code One (Blue) SystemCentral Equipment 1 ls $1.00 $1.00Master Station 5 ea $1.00 $5.00Emergency Call Stations 115 ea $1.00 $115.00Master Antenna Television (Broadband) SystemCentral Equipment 1 ls $1.00 $1.00Outlets 115 ea $1.00 $115.00Motion Intrusion Detector (MID)Central Equipment 1 ls $1.00 $1.00Annunciation Panels 6 ea $1.00 $6.00Detectors 62 ea $1.00 $62.00Security Emergency Call / Duress Alarm System (Panic Button)Central Equipment 1 ls $1.00 $1.00Annunciation Panels 2 ea $1.00 $2.00Panic Buttons 250 ea $1.00 $250.00CCTV MonitoringIntercommunication SystemVideo Teleconferencing System (VTEL)VA Satellite TV SystemElectronic Access Control SystemCentral Equipment 1 ls $1.00 $1.00Monitoring Stations 1 ea $1.00 $1.00Cameras 15 ea $1.00 $15.00Central Equipment 1 ls $1.00 $1.00Master Station 6 ea $1.00 $6.00Staff Stations 34 ea $1.00 $34.00Central Equipment 1 ls $1.00 $1.00Outlets 4 ea $1.00 $4.00Installation <strong>of</strong> VA FurnishedSatellite Dish and Head-endEquipment 1 ls $1.00 $1.00Outlets 2 ea $1.00 $2.00Central equipment, annunciatorpanel, programming, 500 cards 1 ls $1.00 $1.00Access control hardware andcard reader 8 opening $1.00 $8.00Cards 1 per 100 $1.00 $1.00$116.00$121.00$116.00$69.00$253.00SUBTOTAL SPECIAL ITEMS FOR THE ENTIRE CLINIC $751.00$17.00$41.00$5.00$3.00$10.00______Lessor Gov't_______Part III: Schedule B -- Special Requirements___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERSOUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXPART III: SCHEDULE B--SPECIAL REQUIREMENTS (cont.)SECTION 5--SUMMARY PRICE SHEETQty Unit Unit Cost Cost TotalFUNCTIONAL ROOM LISTINGSAcquisition and Materiel <strong>Management</strong> Services (AMMS) $14,444.00Ambulatory CareHealthcare Administration (HAS) $6,922.00Urgent Care (UC) $96,003.00Exam Treatment Modules (ETM) $149,164.00Gastroenterology (GI) $7,301.00Dermatology (Derm) $16,174.00Nutrition (Dietetics) $2,621.00Oncology (ONC) $30,598.00Women's Health / GYN $1,689.00Orthopedics (Ortho) $12,354.00Clinic Based <strong>Home</strong> Care (CBHC) $477.00Patient Education (Pat EDU) $5,062.00SUBTOTAL OF AMBULATORY CARE $328,365.00Audiology and Speech Pathology $138,548.00Canteen $6,681.00Cardiovascular Laboratories-Cardiology Clinic $1,716.00Clinic <strong>Management</strong> Suite $5,917.00Dental Service $291,505.00Education <strong>Facilities</strong> $3,521.00EEG Laboratory $1,576.00Endoscopy Suite-Digestive Diseases Program $59,591.00Engineering Service $10,795.00Environmental <strong>Management</strong> Service $14,894.00Eye Clinic $9,752.00Healthcare Administration Service (HAS) $707.00Lobby $5,996.00Lockers, Toilets and Showers $15,639.00Mental Health ClinicAdministration $7,144.00Day Treatment Center $1,936.00Mental Health Clinic $2,387.00Methadone Maintenance Program $9,528.00Occupational Therapy $7,281.00Substance Abuse Clinic $240.00SUBTOTAL OF MENTAL HEALTH CLINIC $28,516.00Pathology and Laboratory Medicine $117,252.00Pharmacy Service $52,697.00Physical Medicine and Rehabilitation Service $8,611.00Police and Security Service $30.00Prosthetics and Sensory Aids Service $2,932.00Pulmonary Medicine $1,340.00Radiology Service $24,389.00Service Organizations $240.00Supply, Processing and Distribution (SPD) $46,904.00Surgery ServiceAmbulatory Surgery $490,314.00Minor Surgery $91,005.00SUBTOTAL OF SURGERY SERVICE $581,319.00Voluntary Service $4,842.00SUBTOTAL FUNCTIONAL ROOM LISTINGS $1,778,719.00TOTAL ALL SCHEDULE B ITEMS $1,779,470.00OVERHEAD 10 percent $177,947.00PROFIT 10 percent $195,741.70TOTAL PRICE FOR SCHEDULE B--SPECIAL REQUIREMENTS $2,153,158.70______Lessor Gov't_______Part III: Schedule B -- Special Requirements___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]THIS PAGE INTENTIONALLY LEFT BLANK FOR REPRODUCTION PURPOSES.Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]PART IVSCHEDULE C – UNIT COSTS & PRICESPart IV: Schedule C – Unit Costs & Prices – Page 1 <strong>of</strong> 8Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]PART IV: SCHEDULE C – UNIT COSTS & PRICESSchedule C consists <strong>of</strong> the following two sections:SECTION 1: EXHIBIT A--UNIT COSTS FOR ADJUSTMENTS (TO BE USED DURINGCONSTRUCTION PERIOD)Described in Paragraph 3.2 <strong>of</strong> Part 1 Basic Solicitation Requirements.SECTION 2: EXHIBIT B--UNIT PRICE (ADDITIONAL TENANT IMPROVEMENTRATES – FIRST YEAR--$100,000 OR LESS)Described in Paragraph 3.3 <strong>of</strong> Part 1 Basic Solicitation Requirements.Part IV: Schedule C – Unit Costs & Prices – Page 2 <strong>of</strong> 8Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


SOLICITATION FOR OFFERSOUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]SCHEDULE CDEPARTMENT OF VETERANS AFFAIRSEXHIBIT A: UNIT COST FOR ADJUSTMENTS DURING CONSTRUCTION PERIODMAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXUnit <strong>of</strong>MeasureTotalQuantityIncluded inProposedRateCost <strong>of</strong>MaterialsNumber<strong>of</strong> LaborHoursCost LaborHourTotal Price forLabor &MaterialsItem DescriptionSolid Core Wood Doors in Hollow Metal Frames1 Door and frame, interior, Size S: 3'-0" x 7'-0" each $0.002 Door and frame, Half Glass Type 3, Size S: 3'-0" x 7'-0" each $0.003 Door and frame, interior, Size T: 3'-4" x 7'-0" each $0.004 Door and frame, interior, Size U: 3'-6" x 7'-0" each $0.005 Door and frame, Half Glass Type 3, Size U: 3'-6" x 7'-0" each $0.006 Door and frame, interior, Size V: 3'-8" x 7'-0" each $0.007 Door and frame, Half Glass Type 3, Size V: 3'-8" x 7'-0" each $0.008 Door and frame, interior, Size W: 3'-10" x 7'-0" each $0.009 Door and frame, interior, Size X: 4'-0" x 7'-0" each $0.0010 Doors and frame, double, each leaf Size Q: 2'-6" x 7'-0" pair $0.0011 Doors and frame, double, each leaf Size S: 3'-0" x 7'-0" pair $0.0012 Doors and frame, double, each leaf Size T: 3'-4" x 7'-0" pair $0.0013 Doors and frame, double, each leaf Size U: 3'-6" x 7'-0" pair $0.0014 Doors and frame, double, each leaf Size V: 3'-8" x 7'-0" pair $0.0015 Door and frame, C Label, Size S: 3'-0" x 7'-0" each $0.0016 Door and frame, C Label, Size T: 3'-4" x 7'-0" each $0.0017 Door and frame, C Label, Size U: 3'-6" x 7'-0" each $0.0018 Door and frame, C Label, Size V: 3'-8" x 7'-0" each $0.0019Doors and frame, double, C Label, each leaf Size S:3'-0" x 7'-0" pair $0.0020Doors and frame, double, C Label, each leaf Size U:3'-6" x 7'-0" pair $0.00Doors and frame, double, C Label, each leaf Size V:21 3'-8" x 7'-0" pair $0.0022 Door and frame, Lead Lined, Size S: 3'-0" x 7'-0" each $0.0023 Door and frame, Lead Lined, Size T: 3'-4" x 7'-0" each $0.0024 Door and frame, Lead Lined, Size V: 3'-8" x 7'-0" each $0.0025 Door and frame, Lead Lined, Size X: 4'-0" x 7'-0" each $0.0026 Doors and frame, Lead Lined, each leaf Size Q: 2'-6" x 7'-0" pair $0.0027 Door and frame, Sound Rated Type 19, Size V: 3'-8" x 7'-0"Hollow Metal Doors in Hollow Metal Frames28 Hollow Metal Door and frame, interior, Size T: 3'-4" x 7'-0" each $0.00Hollow Metal Door and frame, Detention Type 22, Size T: 3'-4" x29 7'-0" each $0.00Hollow Metal Door and frame, Louvered Type 26, Size U: 3'-6" x30 7'-0" each $0.00Hollow Metal Door and frame, Louvered Type 26, Size V: 3'-8" x31 7'-0" each $0.00Hollow Metal Doors and frame, double, each leaf Size S: 3'-0" x32 7'-0" pair $0.00Hollow Metal Doors and frame, double, each leaf Size U: 3'-6" x33 7'-0" pair $0.0034 Hollow Metal Door and frame, C Label, Size W: 3'-10" x 7'-0" each $0.0035Hollow Metal Doors and frame, double, C Label, each leaf SizeU: 3'-6" x 7'-0" pair $0.0036Hollow metal Door and frame, B Label 90 min, Size X: 4'-0" x 7'-0" each $0.00Security and Vault Doors37 Door and frame, Vault Type 30, Size U: 3'-6" x 7'-0" each $0.0038 Door and frame, Security Type 36, Size S: 3'-0" x 7'-0" each $0.0039 Door and frame, Security Type 36, Size T: 3'-4" x 7'-0" each $0.00Door Hardware and Accessories40 Hardware, Door, HW1 set $0.0041 Hardware, Door, HW4 set $0.0042 Hardware, Door, HW6 set $0.0043 Hardware, Door, HW10 set $0.0044 Hardware, Door, HW12 set $0.0045 Hardware, Door, HW13 set $0.0046 Hardware, Door, HW14 set $0.0047 Hardware, Door, HW18 set $0.0048 Hardware, Door, HW23 set $0.00_____Lessor Gov't______Part IV: Schedule C – Unit Costs & Prices--Page 3 <strong>of</strong> 8_____ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERSOUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]SCHEDULE CDEPARTMENT OF VETERANS AFFAIRSEXHIBIT A: UNIT COST FOR ADJUSTMENTS DURING CONSTRUCTION PERIODMAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXItemDescriptionUnit <strong>of</strong>MeasureTotalQuantityIncluded inProposedRateCost <strong>of</strong>MaterialsNumber<strong>of</strong> LaborHoursCost LaborHourTotal Price forLabor &Materials49 Hardware, Door, HW25 set $0.0050 Hardware, Door, HW29 set $0.0051 Hardware, Door, HW40 set $0.0052 Hardware, Door, HW42 set $0.0053 Hardware, Door, HW43 set $0.0054 Hardware, Door, HW45 set $0.0055 Hardware, Door, HW62 set $0.0056 Hardware, Door, HW67 set $0.0057 Hardware, Door, HW68 set $0.0058 Hardware, Door, HW69 set $0.0059 Hardware, Door, HW79 set $0.0060 Hardware, Door, HW81 set $0.0061 Hardware, Door, HW82 set $0.0062 Hardware, Door, HW104 set $0.0063 Hardware, Door, HW106 set $0.0064 Hardware, Door, HW108 set $0.0065 Hardware, Door, HW109 set $0.0066 Hardware, Door, HW112 set $0.0067 Hardware, Door, HW120 set $0.0068 Hardware, Door, HW121 set $0.0069 Hardware, Door, HW124 set $0.0070 Hardware, Door, HW126 set $0.0071 Hardware, Door, HW129 set $0.0072 Hardware, Door, HW157 set $0.0073 Hardware, Door, HW161 set $0.0074 Door Modification "M", mechanical seal for sound or light set $0.0075 Door Modification "L", Louvers (insert size as required) set $0.0076 Vision panel "A", security, 10" x 10" Laminated Glass each $0.0077Vision panel "F", door, 4" x 25" Fire Resistant Glass w/out WireMesh each $0.0078 Vision panel "V", door, 8" x 10" Lead Glass each $0.0079 Vision panel "T", door, 4" x 25" Tempered Glass each $0.00Partitions80 Partitioning, <strong>of</strong>fice subdividing, fixed, fully-finished, ceiling-high linear foot $0.0081Sound-conditioning for ceiling-high, subdividing partitioningabove linear foot $0.0082<strong>Office</strong> subdividing, full-height, finished floor to underslab(additional cost over ceiling-height) linear foot $0.0083Subdividing, 1-hour Fire resistance Rated, finished floor tounderslab linear foot $0.00Interior Finishes84 AT- Acoustical Ceiling, Tile square foot $0.0085 AT(SP) Acoustical Ceiling with Sprayed Plastic Finish square foot $0.0086 AT(TG)- Acoustical Ceiling with Tegular (reveal) Edge square foot $0.0087 GWB Lay-in Panels in Ceiling Grid square foot $0.0088 AWP- Acoustical Wall Panel square foot $0.0089 CP- Carpet, without Cushion Broadloom square yard $0.0090 CPT- Carpet Tile square yard $0.0091 CT- Ceramic Tile, Wall square foot $0.0092 CT-Ceramic Tile, Floor square foot $0.0093 QT- Quarry Tile square foot $0.0094 P- Paint, Interior Alkyd square foot $0.0095 P- Paint, Interior Latex square foot $0.0096 EPY- Epoxy Coatings square foot $0.0097 SC- High-Build Glazed Coating (Special Coating) square foot $0.0098 RB- Resilient Base linear foot $0.0099 RF- Raised Rubber Flooring square foot $0.00100 RSL- Resilient Sheet Flooring square foot $0.00101 WSL- Welded seam sheet flooring square foot $0.00102 W- Wallcovering, Vinyl Coated Fabric square yard $0.00103 W- Wallcovering, Vinyl Coated Fabric square yard $0.00104 WB- Wall Border, Vinyl Coated Paper, 10" linear foot $0.00_____Lessor Gov't______Part IV: Schedule C – Unit Costs & Prices--Page 4 <strong>of</strong> 8_____ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERSOUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]SCHEDULE CDEPARTMENT OF VETERANS AFFAIRSEXHIBIT A: UNIT COST FOR ADJUSTMENTS DURING CONSTRUCTION PERIODMAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXUnit <strong>of</strong>MeasureTotalQuantityIncluded inProposedRateCost <strong>of</strong>MaterialsNumber<strong>of</strong> LaborHoursCost LaborHourTotal Price forLabor &MaterialsItem DescriptionSpecialties105 Wallcovering, PVC, Protective (WP) square yard $0.00106 Armor plate, door, 35" h x 28.5" each $0.00107 Armor plate, door, 35" h x 34.5" each $0.00108 Armor plate, door, 35" h x 40.5" each $0.00109 Armor plate, door, 35" h x 46.5" each $0.00110 Chairrail each $0.00111 Handrail linear foot $0.00112 Corner Guard, flush, bullnose, 3" wing X 8' H linear foot $0.00113 Track, Curtain, Cubicle, Ceiling Type, Surface Mounted. linear foot $0.00114 Door, accordion, 3'-0" x 7'-0" each $0.00115 Door, accordion, bi-parting, 30'-0" x 10'-0" each $0.00116 Signs, directional each $0.00117 Signs, room identification each $0.00Furnishings118 Blinds, Window per window $0.00119Computer Keyboard Tray (Radiology - Keyboard Nominal Size 8"X 24") each $0.00120 Computer Keyboard Trays (Key Board Nominal Size 7" X 18.5") each $0.00Electrical121 Receptacle, 208V, 40 Amp, wall-mounted each $0.00122 Receptacle, duplex, dedicated, wall-mounted each $0.00123 Receptacle, duplex, floor-mounted each $0.00124 Receptacle, duplex, wall-mounted each $0.00125 Receptacle, GFI, duplex, wall-mounted each $0.00126 Receptacle, quadraplex (double duplex), wall-mounted each $0.00127 Outlet, telephone/data, wall-mounted each $0.00TOTAL EXHIBIT A--UNIT COSTS FOR ADJUSTMENT DURING CONSTRUCTION PERIOD $0.00NOTE: These prices will be submitted as a part <strong>of</strong> the initial <strong>of</strong>fer and negotiated during the course <strong>of</strong> the solicitation period.After prices have been mutually agreed to by the <strong>of</strong>feror and Contracting <strong>Office</strong>r or designee, these prices will not besubject to change at the time <strong>of</strong> Best and Final Offers.Note 1: The above quantities are estimates based on gross square footage.Note 2: Prices quoted shall be fully installed and finished.Offeror Date Contracting <strong>Office</strong>r (or designee) Date_____Lessor Gov't______Part IV: Schedule C – Unit Costs & Prices--Page 5 <strong>of</strong> 8_____ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERSOUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXSCHEDULE CDEPARTMENT OF VETERANS AFFAIRSEXHIBIT B: UNIT PRICES -- ADDITIONAL FIRST YEAR--TENANT IMPROVEMENTSUnit <strong>of</strong>MeasurementCost <strong>of</strong>MaterialNumber <strong>of</strong>LaborHoursCost/ LaborHourTotal Price forLabor &MaterialsItem DescriptionSolid Core Wood Doors in Hollow Metal Frames1 Door and frame, interior, Size S: 3'-0" x 7'-0" each $0.002 Door and frame, Half Glass Type 3, Size S: 3'-0" x 7'-0" each $0.003 Door and frame, interior, Size T: 3'-4" x 7'-0" each $0.004 Door and frame, interior, Size U: 3'-6" x 7'-0" each $0.005 Door and frame, Half Glass Type 3, Size U: 3'-6" x 7'-0" each $0.006 Door and frame, interior, Size V: 3'-8" x 7'-0" each $0.007 Door and frame, Half Glass Type 3, Size V: 3'-8" x 7'-0" each $0.008 Door and frame, interior, Size W: 3'-10" x 7'-0" each $0.009 Door and frame, interior, Size X: 4'-0" x 7'-0" each $0.0010 Doors and frame, double, each leaf Size Q: 2'-6" x 7'-0" pair $0.0011 Doors and frame, double, each leaf Size S: 3'-0" x 7'-0" pair $0.0012 Doors and frame, double, each leaf Size T: 3'-4" x 7'-0" pair $0.0013 Doors and frame, double, each leaf Size U: 3'-6" x 7'-0" pair $0.0014 Doors and frame, double, each leaf Size V: 3'-8" x 7'-0" pair $0.0015 Door and frame, C Label, Size S: 3'-0" x 7'-0" each $0.0016 Door and frame, C Label, Size T: 3'-4" x 7'-0" each $0.0017 Door and frame, C Label, Size U: 3'-6" x 7'-0" each $0.0018 Door and frame, C Label, Size V: 3'-8" x 7'-0" each $0.0019Doors and frame, double, C Label, each leaf Size S:3'-0" x 7'-0" pair $0.0020Doors and frame, double, C Label, each leaf Size U:3'-6" x 7'-0" pair $0.0021Doors and frame, double, C Label, each leaf Size V:3'-8" x 7'-0" pair $0.0022 Door and frame, Lead Lined, Size S: 3'-0" x 7'-0" each $0.0023 Door and frame, Lead Lined, Size T: 3'-4" x 7'-0" each $0.0024 Door and frame, Lead Lined, Size V: 3'-8" x 7'-0" each $0.0025 Door and frame, Lead Lined, Size X: 4'-0" x 7'-0" each $0.0026 Doors and frame, Lead Lined, each leaf Size Q: 2'-6" x 7'-0" pair $0.0027 Door and frame, Sound Rated Type 19, Size V: 3'-8" x 7'-0" $0.00Hollow Metal Doors in Hollow Metal Frames28 Hollow Metal Door and frame, interior, Size T: 3'-4" x 7'-0" each $0.0029Hollow Metal Door and frame, Detention Type 22, Size T: 3'-4" x 7'-0" each $0.0030Hollow Metal Door and frame, Louvered Type 26, Size U: 3'-6" x 7'-0" each $0.0031Hollow Metal Door and frame, Louvered Type 26, Size V: 3'-8" x 7'-0" each $0.0032Hollow Metal Doors and frame, double, each leaf Size S: 3'-0" x 7'-0" pair $0.0033Hollow Metal Doors and frame, double, each leaf Size U: 3'-6" x 7'-0" pair $0.0034 Hollow Metal Door and frame, C Label, Size W: 3'-10" x 7'-0" each $0.0035Hollow Metal Doors and frame, double, C Label, each leafSize U: 3'-6" x 7'-0" pair $0.0036Hollow metal Door and frame, B Label 90 min, Size X: 4'-0" x7'-0" each $0.00Security and Vault Doors37 Door and frame, Vault Type 30, Size U: 3'-6" x 7'-0" each $0.0038 Door and frame, Security Type 36, Size S: 3'-0" x 7'-0" each $0.0039 Door and frame, Security Type 36, Size T: 3'-4" x 7'-0" each $0.00Door Hardware and Accessories40 Hardware, Door, HW1 set $0.0041 Hardware, Door, HW4 set $0.00_____Lessor Gov't______Part IV Schedule C – Unit Costs & Prices--Page 6 <strong>of</strong> 8_____ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERSOUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXSCHEDULE CDEPARTMENT OF VETERANS AFFAIRSEXHIBIT B: UNIT PRICES -- ADDITIONAL FIRST YEAR--TENANT IMPROVEMENTSUnit <strong>of</strong>MeasurementCost <strong>of</strong>MaterialNumber <strong>of</strong>LaborHoursCost/ LaborHourTotal Price forLabor &MaterialsItem Description42 Hardware, Door, HW6 set $0.0043 Hardware, Door, HW10 set $0.0044 Hardware, Door, HW12 set $0.0045 Hardware, Door, HW13 set $0.0046 Hardware, Door, HW14 set $0.0047 Hardware, Door, HW18 set $0.0048 Hardware, Door, HW23 set $0.0049 Hardware, Door, HW25 set $0.0050 Hardware, Door, HW29 set $0.0051 Hardware, Door, HW40 set $0.0052 Hardware, Door, HW42 set $0.0053 Hardware, Door, HW43 set $0.0054 Hardware, Door, HW45 set $0.0055 Hardware, Door, HW62 set $0.0056 Hardware, Door, HW67 set $0.0057 Hardware, Door, HW68 set $0.0058 Hardware, Door, HW69 set $0.0059 Hardware, Door, HW79 set $0.0060 Hardware, Door, HW81 set $0.0061 Hardware, Door, HW82 set $0.0062 Hardware, Door, HW104 set $0.0063 Hardware, Door, HW106 set $0.0064 Hardware, Door, HW108 set $0.0065 Hardware, Door, HW109 set $0.0066 Hardware, Door, HW112 set $0.0067 Hardware, Door, HW120 set $0.0068 Hardware, Door, HW121 set $0.0069 Hardware, Door, HW124 set $0.0070 Hardware, Door, HW126 set $0.0071 Hardware, Door, HW129 set $0.0072 Hardware, Door, HW157 set $0.0073 Hardware, Door, HW161 set $0.0074 Door Modification "M", mechanical seal for sound or light set $0.0075 Door Modification "L", Louvers (insert size as required) set $0.0076 Vision panel "A", security, 10" x 10" Laminated Glass each $0.00Vision panel "F", door, 4" x 25" Fire Resistant Glass w/out77 Wire Mesh each $0.0078 Vision panel "V", door, 8" x 10" Lead Glass each $0.0079 Vision panel "T", door, 4" x 25" Tempered Glass each $0.00PartitionsPartitioning, <strong>of</strong>fice subdividing, fixed, fully-finished, ceilinghigh80linear foot $0.00Sound-conditioning for ceiling-high, subdividing partitioning81 above linear foot $0.00<strong>Office</strong> subdividing, full-height, finished floor to underslab82 (additional cost over ceiling-high partition) linear foot $0.00Subdividing, 1-hour Fire Resistance Rated, finished floor to83 underslab linear foot $0.00Interior Finishes84 AT- Acoustical Ceiling, Tile square foot $0.0085 AT(SP) Acoustical Ceiling with Sprayed Plastic Finish square foot $0.0086 AT(TG)- Acoustical Ceiling with Tegular (reveal) Edge square foot $0.0087 GWB Lay-in Panels in Ceiling Grid square foot $0.0088 AWP- Acoustical Wall Panel square foot $0.0089 CP- Carpet, without Cushion Broadloom square yard $0.0090 CPT- Carpet Tile square yard $0.0091 CT- Ceramic Tile, Wall square foot $0.0092 CT-Ceramic Tile, Floor square foot $0.0093 QT- Quarry Tile square foot $0.0094 P- Paint, Interior Alkyd square foot $0.00_____Lessor Gov't______Part IV Schedule C – Unit Costs & Prices--Page 7 <strong>of</strong> 8_____ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERSOUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXSCHEDULE CDEPARTMENT OF VETERANS AFFAIRSEXHIBIT B: UNIT PRICES -- ADDITIONAL FIRST YEAR--TENANT IMPROVEMENTSUnit <strong>of</strong>MeasurementCost <strong>of</strong>MaterialNumber <strong>of</strong>LaborHoursCost/ LaborHourTotal Price forLabor &MaterialsItem Description95 P- Paint, Interior Latex square foot $0.0096 EPY- Epoxy Coatings square foot $0.0097 SC- High-Build Glazed Coating (Special Coating) square foot $0.0098 RB- Resilient Base linear foot $0.0099 RF- Raised Rubber Flooring square foot $0.00100 RSL- Resilient Sheet Flooring square foot $0.00101 WSL- Welded seam sheet flooring square foot $0.00102 W- Wallcovering, Vinyl Coated Fabric square yard $0.00103 W- Wallcovering, Vinyl Coated Fabric square yard $0.00104 WB- Wall Border, Vinyl Coated Paper, 10" linear foot $0.00Specialties105 Wallcovering, PVC, Protective (WP) square yard $0.00106 Armor plate, door, 35" h x 28.5" each $0.00107 Armor plate, door, 35" h x 34.5" each $0.00108 Armor plate, door, 35" h x 40.5" each $0.00109 Armor plate, door, 35" h x 46.5" each $0.00110 Chair rail each $0.00111 Handrail linear foot $0.00112 Corner Guard, flush, bullnose, 3" wing x 8' H linear foot $0.00113 Track, Curtain, Cubicle, Ceiling Type, Surface Mounted. linear foot $0.00114 Door, accordion, 3'-0" x 7'-0" each $0.00115 Door, accordion, bi-parting, 30'-0" x 10'-0" each $0.00116 Signs, directional each $0.00117 Signs, room identification each $0.00Furnishings118 Blinds, Window per window $0.00Computer Keyboard Tray (Radiology - Keyboard Nominal119 Size 8" X 24") each $0.00Computer Keyboard Trays (Key Board Nominal Size 7" X120 18.5") each $0.00Electrical121 Receptacle, 208V, 40 Amp, wall-mounted each $0.00122 Receptacle, duplex, dedicated, wall-mounted each $0.00123 Receptacle, duplex, floor-mounted each $0.00124 Receptacle, duplex, wall-mounted each $0.00125 Receptacle, GFI, duplex, wall-mounted each $0.00126 Receptacle, quadraplex (double duplex), wall-mounted each $0.00127 Outlet, telephone/data, wall-mounted each $0.00$0.00These prices will be submitted as a part <strong>of</strong> the initial <strong>of</strong>fer and negotiated during the course <strong>of</strong> the solicitation period.After prices have been mutually agreed to by the <strong>of</strong>feror and Contracting <strong>Office</strong>r or designee, these prices will not besubject to change at the time <strong>of</strong> Best and Final Offers.Offeror Date Contracting <strong>Office</strong>r (or designee) Date_____Lessor Gov't______Part IV Schedule C – Unit Costs & Prices--Page 8 <strong>of</strong> 8_____ <strong>of</strong> _____ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]PART VSCHEDULE D – BID SUMMARY FORMPart V: Schedule D –Bid Summary Form – Page 1 <strong>of</strong> 2Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


SOLICITATION FOR OFFERSOUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]SCHEDULE DDEPARTMENT OF VETERANS AFFAIRSBID SUMMARY FORMMAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXI. Site Improvement Costs $0.00(Excludes the cost <strong>of</strong> the land and any items contained under IV.A. and IV.B. below.)II. Shell Costs $0.00III. Schedule C Costs $0.00(Interior partitions, doors and hardware, finishes; and certain furnishings and electrical items. Refer toSchedule C, Exhibit A for requirements.)Subtotal $0.00IV.Specific Enhanced Federal Requirement CostsA. Sustainable Design and Energy Efficiency $0.00(Refer to Part I Section 4 General Design Criteria for requirements)B. Physical Security (except systems in Schedule B) $0.00(Refer to Part I Section 4 General Design Criteria for requirements)Subtotal Specific Enhanced Federal Requirement Costs $0.00V. Total Price for Schedule B $0.00(Refer to Section 5, Summary Price Sheet in Schedule B)VI. All Other Build-out Required by <strong>SFO</strong> $0.00TOTAL PROJECT COST $0.00_____Lessor Gov't______Part V Schedule D – Bid Summary--Page 2 <strong>of</strong> 2_____ <strong>of</strong> _____ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> No. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]PART VISCHEDULE EPart VI: Schedule E – Room Finish, Door & Hardware -- Page 1 <strong>of</strong> 30Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> No. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]PART VI: SCHEDULE E--ROOM FINISH, DOORS & HARDWARESECTION 1 ROOM FINISH, DOOR AND HARDWARE SCHEDULE--GENERAL ........................ 31.1 ROOM FINISHES, DOOR AND HARDWARE SCHEDULE ..................................................... 31.1.1 USE OF SCHEDULE E ................................................................................................ 31.1.2 OTHER REQUIREMENTS ........................................................................................... 51.1.3 WALLCOVERING PROTECTIVE (WP), RIGID PVC SHEET ..................................... 51.1.4 STAIRWAYS ................................................................................................................ 51.2 DOORS ..................................................................................................................................... 51.2.1 DOORS ........................................................................................................................ 51.2.2 DOOR TYPES .............................................................................................................. 71.2.3 DOOR SIZES ............................................................................................................... 81.2.4 LEAD LINED DOORS AND FRAMES// ....................................................................... 91.3 FINISH HARDWARE ............................................................................................................... 101.3.1 GENERAL .................................................................................................................. 101.3.2 BUTT HINGES ........................................................................................................... 101.3.3 CONTINUOUS HINGES ............................................................................................ 111.3.4 DOOR CLOSING DEVICES ...................................................................................... 121.3.5 DOOR STOPS ........................................................................................................... 121.3.6 LOCKS AND LATCHES ............................................................................................. 131.3.7 PUSH-BUTTON COMBINATION LOCKS ................................................................. 131.3.8 ELECTROMAGNETIC LOCKS .................................................................................. 141.3.9 CARD READERS ....................................................................................................... 141.3.10 ELECTRIC STRIKES ................................................................................................. 151.3.11 KEYS .......................................................................................................................... 151.3.12 KEY CABINET ........................................................................................................... 151.3.13 ARMOR PLATES, COMBINATION KICK-MOP PLATES AND DOOR EDGING ...... 161.3.14 EXIT DEVICES .......................................................................................................... 171.3.15 WEATHERSTRIPS (FOR EXTERIOR DOORS) ....................................................... 171.3.16 MISCELLANEOUS HARDWARE .............................................................................. 171.3.17 PADLOCKS FOR VARIOUS DOORS, GATES AND HATCHES .............................. 171.3.18 HARDWARE SETS .................................................................................................... 18SECTION 2 SCHEDULE EPart VI: Schedule E – Room Finish, Door & Hardware -- Page 2 <strong>of</strong> 30Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> No. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]PART VI SCHEDULE E--ROOM FINISH, DOORS & HARDWARESECTION 1 ROOM FINISH, DOOR AND HARDWARE SCHEDULE--GENERALSchedule E lists each type <strong>of</strong> space or room required in the outpatient clinic. The followinginformation is listed for each space in the Schedule:Department, Area and FunctionFloor, Wall and Ceiling FinishesDoor Symbol and Hardware SetIf the Lessor believes that there are spaces or conditions not included in this Schedule, thequestion shall be referred to the Contracting <strong>Office</strong>r.1.1 ROOM FINISHES, DOOR AND HARDWARE SCHEDULE1.1.1 USE OF SCHEDULE ETHE REQUIREMENTS IN THIS SCHEDULE APPLY TO ALL SPACES TO BEOCCUPIED BY VA IN THE OUTPATIENT CLINIC. LESSOR SHALL PROVIDEMATERIALS, FINISHES, DOORS, FRAMES, AND HARDWARE IN ACCORDANCEWITH THIS SCHEDULE AND THE REQUIREMENTS SPECIFIED IN THIS <strong>SFO</strong>.Lessor shall provide each space with door(s) <strong>of</strong> the type and size as listed in Schedule E withhardware as noted. Doors and hardware requirements are indicated by their respective doorsymbols and hardware set numbers in this Schedule. Additional requirements are defined inParagraph 1.3, "Doors and Hardware".The Lessor shall provide room finishes in each room in accordance with Schedule E. Finishesare shown in the schedule for the floor, base, wainscot, wall, and ceiling surfaces for eachroom or space. The following are abbreviations used for materials and codes throughout theroom finishes, door, and hardware schedule. The Lessor shall coordinate abbreviations usedin the construction documents prepared by the Lessor with the abbreviations and symbolsused in this <strong>SFO</strong>.ADOAFATAT(SP)AT(TG)AWFAWPBPBRCCMUAutomatic Door OperatorAccess FlooringAcoustical Ceiling (Tile)Acoustical Ceiling (with Sprayed Plastic Finish)Acoustical Ceiling (with Tegular Edge)Acoustical Wall Fabric (Tackable)Acoustical Wall PanelBrick Pavers (Unit Pavers)Brick (Unit Masonry)ConcreteConcrete Masonry Units (Unit Masonry)Part VI: Schedule E – Room Finish, Door & Hardware -- Page 3 <strong>of</strong> 30Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> No. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]CPCPTCTEFTREPYERFEXEXPGLGWBHWLMMATMCNFNOPPCPCPPFWPLPUTQTRAFRBRFRSFSCSPSPECSTTTVCTVPWCarpet (without Cushion Broadloom)Carpet TileCeramic Tile (Floor, Base, and Wall)Existing Finish to RemainEpoxy (Coatings)Epoxy Resinous FlooringExistingExposedGlass (Glazing)Gypsum Wallboard SystemsHardware Set (Finish or Builders Hardware)Latex Mastic FlooringMaterialMulti-Color CoatingNatural FinishNumberPaint (Exterior, Interior, Transparent Finishes)Precast (Architectural Precast Concrete Panels)Portland Cement PlasterPolypropylene Fabric WallcoveringPlasterPolyurethaneQuarry TileResilient Athletic FlooringResilient Base (Rubber, Vinyl)Raised Rubber FlooringResilient Sheet FlooringHigh Build Glazed Coating (Special Coating)Special FacedSpecial (Architect's Choice)Stone (Cast)Terrazzo Tile (Plastic Matrix)Resilient Tile Flooring (Vinyl Composition Tile)Veneer PlasterWallcovering (Vinyl Coated Fabric)Part VI: Schedule E – Room Finish, Door & Hardware -- Page 4 <strong>of</strong> 30Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> No. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]WBWDWPWSFWall BorderWoodWallcovering Protective (Rigid PVC Sheet)Welded Seam Sheet Flooring1.1.2 OTHER REQUIREMENTSA. Safety GlassThere are two (2) types <strong>of</strong> safety glass that may be required in Interior Spaces; these are:B. Laminated Fire Glass shall be used in fire rated assembliesTempered Glass ("T") shall be used in all other Observations Windows and Doors with visionpanels, including side lights.C. Wall Protection at Drinking Fountains and LavatoriesProvide vinyl wall covering behind Drinking Fountain Alcoves where wallboard or plaster finishoccur and behind lavatories and end walls in examination rooms, treatment rooms, etc. at aminimum 50 inches wide (or terminating at the nearest inside corner). The vinyl wall coveringshall go from base to ceiling.1.1.3 WALLCOVERING PROTECTIVE (WP), RIGID PVC SHEETInstall rigid PVC sheet wall protection at locations indicated //in Schedule E// //on conceptualdrawings// over primed GWB //or plaster// substrate. //Provide impact-resistant GWB underwallcovering <strong>of</strong> 0.060-inch or greater thickness.// Do not seam within 24 inches <strong>of</strong> internal orexternal corners. Install covering before installation <strong>of</strong> bases, cabinets, hardware, or itemsattached to or spaced slightly from wall surface. Do not install covering more than 1/4 inchbelow top <strong>of</strong> resilient base. Terminate top <strong>of</strong> wallcovering at //handrail// //chair rail// //[____inches above finished floor]// //[______]//.1.1.4 //STAIRWAYSIn stairways use Molded Rubber Treads on stairs and Resilient Tile (VCT) on floor landingsand rubber tile on intermediate landings except for stairs exposed to the weather or those instrictly utilitarian areas such as shops, building service equipment rooms, etc.//1.2 DOORS1.2.1 DOORSThe Door Symbol column in Schedule E identifies the type, size and special features <strong>of</strong> doorsfor use in a room or space. The number and letters used for the Door Symbol have thefollowing meaning; the first number indicates door type and door material (odd nos. wood andeven nos. steel), e.g., "1, 2, 4, etc.". The first letter (or letters) indicate door size e.g. "S, UU, V,Part VI: Schedule E – Room Finish, Door & Hardware -- Page 5 <strong>of</strong> 30Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> No. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]etc." The letter after a dash (e.g., "-A") indicates a modification to a door. Use these symbolsand designations at door openings on floor plan drawings.For additional door requirements see Architectural Criteria in Sections 6 and 7 in Part I <strong>of</strong> the<strong>SFO</strong>.Door Swing: Doors to Housekeeping Aids Closets (HAC) shall open out. HAC doors shallswing out 180 o where possible.Part VI: Schedule E – Room Finish, Door & Hardware -- Page 6 <strong>of</strong> 30Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> No. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]1.2.2 DOOR TYPESPart VI: Schedule E – Room Finish, Door & Hardware -- Page 7 <strong>of</strong> 30Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> No. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]1.2.3 DOOR SIZESPart VI: Schedule E – Room Finish, Door & Hardware -- Page 8 <strong>of</strong> 30Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> No. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]1.2.4 //LEAD LINED DOORS AND FRAMES//Part VI: Schedule E – Room Finish, Door & Hardware -- Page 9 <strong>of</strong> 30Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> No. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]1.3 FINISH HARDWARE1.3.1 GENERALA. Hardware Set Numbers on ScheduleExcept for protective plates, door stops, mutes, thresholds and the like specified herein,hardware requirements for each door are indicated in the Room Finish and Door Schedule bynumbers that correspond to the following hardware sets listed in this <strong>SFO</strong>.B. Manufacturers' Catalog Number ReferencesWhere manufacturers' products are specified herein, products <strong>of</strong> other manufacturers whichare considered equivalent to those specified may be used. Manufacturers whose products arespecified are identified by abbreviations as follows:Adams-Rite Adams Rite Mfg. Co. Glendale, CAGlynn Johnson Glynn Johnson Co. Chicago, ILLCN LCN Closers Princeton, ILFiremark Rixon-Firemark Co. Chicago, ILHager Hager Hinge Company Saint Louis, MOStanley The Stanley Works New Britain, CTTrimco Triangle Brass Mfg. Co. Los Angeles, CAUnican Simplex Security Systems Collinsville, CTVon Duprin Von Duprin Hardware Co. Indianapolis, INZero Zero Weather Stripping Co. New York, NYC. KeyingAll cylinders shall be keyed into Grand Master Key System. Provide removable core cylindersthat are removable only with a special key or tool without disassembly <strong>of</strong> knob or locksetCylinders shall be 7 pin type. Keying information shall be furnished at a later date by theResident Engineer.1.3.2 BUTT HINGESA. ANSI A156.1.The following types <strong>of</strong> butt hinges shall be used for the types <strong>of</strong> doors listed, except whereotherwise specified:(1) Exterior DoorsType A2112 for doors 900 mm (3 feet) wide or less and Type A2111 for doors over 900 mm (3feet) wide. Hinges for exterior doors shall have non-removable pins.(2) Interior DoorsType 8112 for doors 900 mm (3 feet) wide or less and Type A8111 for doors over 900 mm (3feet) wide.Part VI: Schedule E – Room Finish, Door & Hardware -- Page 10 <strong>of</strong> 30Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> No. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY](3) Automatic doors hung on buttsType A2111 for exterior doors and aluminum doors, and Type A8111 for other doors.(4) Labeled Wood Fire DoorsType 8411 or Type 8412; these hinges shall be thru bolted to door with hex nuts and bolts.1.3.3 CONTINUOUS HINGESA. ANSI/BHMA A156.26//Grade 1-150// //Grade 1-300// //Grade 1-600//.(1) Listed under Category N in BHMA's "Certified Product Directory."B. GeneralMinimum 0.120-inch- (3.0-mm-) thick, hinge leaves with minimum overall width <strong>of</strong> 4 inches(102 mm); fabricated to full height <strong>of</strong> door and frame and to template screw locations; withcomponents finished after milling and drilling are complete:(1) Fire PinsSteel pins to hold labeled fire doors in place if required by tested listing.C. Continuous, Barrel-Type HingesHinge with knuckles formed around a pin that extends entire length <strong>of</strong> hinge.(1) Base Metal for Exterior HingesStainless steel.(2) Base Metal for Interior Hinges//Stainless steel// //Steel// //Aluminum//.(3) Base Metal for Hinges for Fire-Rated Assemblies//Stainless steel// //Steel//.(4) ManufacturersHager Companies.Markar Architectural Products, Inc.; a Subsidiary <strong>of</strong> Adams Rite Manufacturing Co.McKinney Products Company; an ASSA ABLOY Group company.Stanley Commercial Hardware; Division. <strong>of</strong> the Stanley Works and Zero International.D. Continuous, Gear-Type HingesExtruded-aluminum, pinless, geared hinge leaves; joined by a continuous extruded-aluminumchannel cap; with concealed, self-lubricating thrust bearings.(1) ManufacturersBommer Industries, Inc.Hager Companies.Part VI: Schedule E – Room Finish, Door & Hardware -- Page 11 <strong>of</strong> 30Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> No. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]McKinney Products Company; an ASSA ABLOY Group company.Pemko Manufacturing Co.Select Products Limited.Zero International.1.3.4 DOOR CLOSING DEVICESClosing devices shall be products <strong>of</strong> one manufacturer for each type required.The closer shall have 50 percent adjustable closing force over minimum value for that closerand have adjustable hydraulic back check effective between 60 degrees and 85 degrees <strong>of</strong>door opening.Where specified, closer shall have hold-open feature.Size Requirements: Size closers in accordance with manufacturer’s recommendations orprovide multi-size closers, sizes 1 through 6.1.3.5 DOOR STOPSA. Conform to ANSI A156.16.B. Provide door stops wherever an opened door or any item <strong>of</strong> hardware thereon would strikea wall, column, equipment or other parts <strong>of</strong> building construction. For concrete, masonry orquarry tile construction, use lead expansion shields for mounting door stops.C. Where cylindrical locks with turn pieces or pushbuttons occur, equip wall bumpers TypeL02251 (rubber pads having concave face) to receive turn piece or button.D. Substitute floor stops Type L02141 or L02161 as appropriate, when wall bumpers wouldnot provide an effective door stop.E. Where drywall partitions occur, use floor stops, Type L02141 or L02161.F. Provide stop Type L02011 or L02181, as applicable for exterior doors.G. Omit stops where floor mounted door holders are required and where automatic operateddoors occur.H. Provide appropriate roller bumper for each set <strong>of</strong> doors (except where closet doors occur)where two doors would interfere with each other in swinging.I. Provide appropriate door mounted stop on doors in individual toilets where floor or wallmounted stops cannot be used.J. Provide overhead surface applied stop Type C02541, ANSI A156.8 on patient toilet doorsin bedrooms where toilet door could come in contact with the bedroom door.K. Provide door stops on doors where combination closer magnetic holders are specified.Part VI: Schedule E – Room Finish, Door & Hardware -- Page 12 <strong>of</strong> 30Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> No. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]1.3.6 LOCKS AND LATCHESA. Conform to ANSI A156.2. Locks and latches for doors 45 mm (1-3/4 inch) thick or overshall have beveled fronts. Lock cylinders shall have not less than // six pins // seven pins //.Cylinders for all locksets shall be removable core type. // Cylinders shall be furnished withconstruction removable cores and construction master keys. // Cylinder shall be removable byspecial key or tool. Construct all cores so that they will be interchangeable into the corehousings <strong>of</strong> all mortise locks, rim locks, cylindrical locks, and any other type lock included inthe Great Grand Master Key System. Disassembly <strong>of</strong> lever or lockset shall not be required toremove core from lockset. All locksets or latches on double doors with fire label shall havelatch bolt with 19 mm (3/4 inch) throw. Provide temporary keying device or construction core <strong>of</strong>allow opening and closing during construction and prior to the installation <strong>of</strong> final cores.B. In addition to above requirements, locks and latches shall comply with followingrequirements:1. Cylindrical Lock and Latch Sets: levers shall meet ADA (Americans with Disabilities Act)requirements. Cylindrical locksets shall be series 4000 Grade I. Knobs for series 4000 lockand latch sets shall have 57 mm (2-1/4 inch) diameters. Where two turn pieces are specifiedfor lock F76, turn piece on inside knob shall lock and unlock inside knob, and turn piece onoutside knob shall unlock outside knob when inside knob is in the locked position. (Thisfunction is intended to allow emergency entry into these rooms without an emergency key orany special tool.)2. Mortise Lock and Latch Sets: Conform to ANSI/BHMA A156.13. Mortise locksets shall beseries 1000, minimum Grade 2. All locksets and latchsets shall have lever handles similar toFalcon S-lever Design. Lever handle shall be fabricated from wrought stainless steel. Nosubstitute lever design or material shall be accepted. All locks and latchsets shall be furnishedwith curved lip strike and wrought box. Furnish armored fronts for all mortise locks.3. Auxiliary locks shall be as specified under hardware sets and conform to ANSI A156.5.1.3.7 PUSH-BUTTON COMBINATION LOCKSA. ANSI/BHMA A156.5, Grade 1. Mechanical or electrically operated as indicated.B. <strong>Construction</strong>: Heavy duty cylindrical lock housing conforming to ANSI/BHMA A156.2,Grade 1. Lever handles and operating components in compliance with the UFAS and theADA Accessibility Guidelines.C. Special Features: Key override to permit a master keyed security system and a keyactivated passage feature to allow access without using the entry code.D. Manufacturers:1. Alarm Lock.2. Code Locks, LLC3. Locknetics; an Ingersoll Rand company.4. Kaba Ilco.Part VI: Schedule E – Room Finish, Door & Hardware -- Page 13 <strong>of</strong> 30Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> No. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]1.3.8 ELECTROMAGNETIC LOCKSA. ANSI/BHMA A156.23Electrically powered, <strong>of</strong> strength and configuration indicated; with electromagnet attached t<strong>of</strong>rame and armature plate attached to door. Listed under Category E in BHMA's "CertifiedProduct Directory."(1) TypeFull exterior or full interior, as required by application indicated.(2) Strength Ranking//1500 lbf (6672 N)// //1000 lbf (4448 N)// //500 lbf (2224 N)//.(3) Inductive Kickback Peak VoltageNot more than //53// //0// V.(4) Residual MagnetismNot more than //4 lbf (18 N)// //0 lbf (0 N)// to separate door from magnet.B. Delayed-Egress LocksBHMA A156.24.// Listed under Category G in BHMA's "Certified Product Directory". //(1) Means <strong>of</strong> Egress DoorsLock releases within 15 seconds after applying a force not more than 15 lbf (67 N) for notmore than 3 seconds, as required by NFPA 101.(2) Security GradeActivated from secure side <strong>of</strong> door by initiating device.(3) Movement GradeActivated by door movement as initiating device.C. ManufacturersDoor Controls International.Doorguard Systems, Inc.Dortronics Systems, Inc.DynaLock Corp.Locknetics; an Ingersoll-Rand Company.Rutherford Controls Int'l. Corp.SARGENT Manufacturing Company; an ASSA ABLOY Group company.Securitron Magnalock Corporation; an ASSA ABLOY Group company.Security Door Controls.1.3.9 CARD READERSProvide and install card readers where indicated. Integrate card readers with other specifiedsystems and systems that are in place.Part VI: Schedule E – Room Finish, Door & Hardware -- Page 14 <strong>of</strong> 30Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> No. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]1.3.10 ELECTRIC STRIKESA. ANSI/ BHMA A156.31 Grade 1.B. General: Use fail-secure electric strikes with fire-rated devices.C. Manufacturers:1. Adams Rite Manufacturing Co.2. Folger Adam Security Inc.; an ASSA ABLOY Group company.3. HES, Inc.; an ASSA ABLOY Group company.4. Locknetics; an Ingersoll-Rand Company.5. Precision Hardware, Inc.6. Von Duprin; an Ingersoll-Rand Company.1.3.11 KEYSA. Stamp all keys with change number and key set symbol. Furnish keys in quantities as follows:Locks/KeysCylinder locksCylinder lock change key blanksMaster-keyed setsGrand Master setsControl keyQuantity2 keys each100 each different key way6 keys each6 keys each1 key1.3.12 KEY CABINETA. ANSI Standard A156.5. Provide key cabinet made <strong>of</strong> cold rolled, 1.2 mm (0.0478 inch)thick furniture steel electro-welded. Doors shall have "no sag" continuous brass-pin piano typehinge and be equipped with chrome plated locking door handles, hook cam and twoparasentric keys. All locks shall be nickel plated with solid brass pin tumbler cylinder keyed asdirected. Key Cabinet and Key Control System shall accommodate all keys for this project plus25 percent.B. Key tags shall consist <strong>of</strong> two sets: Permanent self-locking and loan key snaphook typewith tag colors as follows: Red fiber marker <strong>of</strong> the permanent self-locking type approximately32 mm (1-1/4 inch) in diameter engraved with the legend "FILE KEY MUST NOT BELOANED." Also furnish for each hook a white cloverleaf key marker with snap-hooks engravedwith the legend "LOAN KEY."Part VI: Schedule E – Room Finish, Door & Hardware -- Page 15 <strong>of</strong> 30Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> No. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]C. The manufacturer <strong>of</strong> the lock cylinders and locks shall attach a key tag to keys <strong>of</strong> eachlock cylinder and shall mark thereon the respective item number and key change number.Provide each group <strong>of</strong> keys in a key gathering envelope (supplied by Key CabinetManufacturer) in which the lock manufacturer shall include the following information: Itemnumber, key change number and door number. The contractor shall furnish the Key CabinetManufacturer the hardware and keying schedules and change keys.D. The Key Cabinet Manufacturer shall set up a three-way cross index system, includingmaster keys, listing the keys alphabetically, the hooks numerically and the key changesnumerically on different colored index cards. Index cards shall be typewritten and inserted in adurable binder. Attach the keys to the two sets <strong>of</strong> numbered tags supplied with the cabinet.(The permanent tag and the loan key tag). Instruct the owner in proper use <strong>of</strong> the system.Install cabinet as directed by the Resident Engineer.1.3.13 ARMOR PLATES, COMBINATION KICK-MOP PLATES AND DOOR EDGINGA. Conform to ANSI Standard A156.6.B. Provide protective plates and door edging as specified below:1. Kick-mop plates and armor plates plastic or metal, Type J100 series, color as required.2. Provide kick-mop plates for both sides <strong>of</strong> each door, except where noted as not required.Kick-mop plates shall be 125 mm (5 inches) high. On push side <strong>of</strong> doors where jamb stopextends to floor, make combination kick-mop plates 38 mm (1-1/2 inches) less than width <strong>of</strong>door, except pairs <strong>of</strong> metal doors which shall have plates 25 mm (1 inch) less than width <strong>of</strong>each door. Extend all other combination kick-mop plates to within 6 mm (1/4 inch) <strong>of</strong> eachedge <strong>of</strong> doors. Kick mop plates shall butt astragals. For jamb stop requirements, seespecification sections pertaining to door frames.3. Kick-mop plates are not required on following door sides:a) Armor plate side <strong>of</strong> doors;b) Exterior side <strong>of</strong> exterior doors;c) Closet side <strong>of</strong> closet doors;d) Storage side <strong>of</strong> doors to or from storage spaces; ande) Both sides <strong>of</strong> aluminum entrance doors.4. Armor plates for doors are listed under "Hardware Sets". Armor plates shall be 875 mm(35 inches) high and 38 mm (1-1/2 inches) less than width <strong>of</strong> doors, except on pairs <strong>of</strong> metaldoors. Plates on pairs <strong>of</strong> metal doors shall be 25 mm (1 inch) less than width <strong>of</strong> each door.Where top <strong>of</strong> intermediate rail <strong>of</strong> door is less than 875 mm (35 inches) from door bottom,extend armor plates to within 13 mm (1/2 inch) <strong>of</strong> top rail. On doors equipped with panicdevices, extend armor plates to within 13 mm (1/2 inch) <strong>of</strong> panic bolt cross bar.5. Where louver or grille occurs in lower portion <strong>of</strong> doors, substitute stretcher plate and kickmopplate in place <strong>of</strong> armor plate. Size <strong>of</strong> stretcher plate and kick-mop plate shall be 125 mm(5 inches) high.Part VI: Schedule E – Room Finish, Door & Hardware -- Page 16 <strong>of</strong> 30Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> No. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]1.3.14 EXIT DEVICESA. Conform to ANSI Standard A156.3. Exit devices shall be Grade 1; type and function arespecified in hardware sets. Provide flush with finished floor strikes for vertical rod exit devicesin interior <strong>of</strong> building. Trim shall have lever handles similar to locksets, unless otherwisespecified.B. Exit devices for fire doors shall comply with Underwriters Laboratories, Inc., requirementsfor Fire Exit Hardware. Submit pro<strong>of</strong> <strong>of</strong> compliance.1.3.15 WEATHERSTRIPS (FOR EXTERIOR DOORS)Conform to ANSI A156.22. Air leakage shall not to exceed 0.50 CFM per foot <strong>of</strong> crack length(0.000774m 3 /s/m).1.3.16 MISCELLANEOUS HARDWAREA. Cylinders for Various Partitions and Doors: Key cylinders same as entrance doors <strong>of</strong> areain which partitions and door occur. Provide cylinders to operate locking devices wherespecified for following partitions and doors:1. Folding doors and partitions.2. Slide-up doors.3. Day gate on vault door.D. Mutes: Conform to ANSI A156.16. Provide door mutes or door silencers Type L03011, <strong>of</strong>white or light gray color, on each steel door frame, except lead-lined frames and frames forsound-resistant, lightpro<strong>of</strong> and electromagnetically shielded doors. Furnish 3 mutes for singledoors and 2 mutes for each pair <strong>of</strong> doors, except double-acting doors. Provide 4 mutes orsilencers for frames for each Dutch type door. Provide 2 mutes for each edge <strong>of</strong> sliding doorwhich would contact door frame.1.3.17 PADLOCKS FOR VARIOUS DOORS, GATES AND HATCHESA. ASTM E883, size 50 mm (2 inch) wide chain; furnish extended shackles as required by jobconditions. Provide padlocks, with key cylinders, for each door in following areas as noted.B. Key padlocks as follows:1. Chain Link Fence Gates for Electrical Substation and other Fenced Buildings or Areas:Engineer's set, except as otherwise specified.2. Chain Link Fence Gates for Oxygen Storage: Maintenance supply set.3. Ro<strong>of</strong> Access and Scuttles: Engineer's set.Part VI: Schedule E – Room Finish, Door & Hardware -- Page 17 <strong>of</strong> 30Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> No. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]1.3.18 HARDWARE SETSFollowing sets <strong>of</strong> hardware correspond to hardware numbers shown in Room Finish and DoorSchedule. Where hardware set for a single door is specified for a pair <strong>of</strong> doors; equip eachleaf <strong>of</strong> such pair <strong>of</strong> doors with set noted. Only those hardware sets that are referenced in theSchedule will be required. Disregard breaks in hardware set numbering sequence. Disregardhardware sets listed below but not shown in Schedule.Part VI: Schedule E – Room Finish, Door & Hardware -- Page 18 <strong>of</strong> 30Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> No. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]HARDWARE SETSHW 1Butts as requiredDoor pullPush plateCloser C02011HW 6Butts as requiredDoor pullsPush platesCombination closer holder C00241Armor plateHW 12Butts as requiredPush-pull plate J303Arm pull double base J400Closer C02051HW 14Butts as requiredLock F76Provide turn piece on both sides <strong>of</strong> lockHW 23Butts as requiredLock F81 or F04 where notedHW 29Butts as required2 Flush boltsLatch F75HW 42Butts as requiredLock F87 or 161 W-4Closer C02011Holder C22511HW 45Butts as requiredLock F81 or F04 where notedCloser C02011HW 4Butts as requiredDoor pullPush plateCloser C02011Armor plateHolder C22511HW 10Butts as requiredDeadlock F18 x rectangular strike (no lip)Push pull plate J303Note: No cylinder or trim on room side <strong>of</strong> door.HW 13Butts as requiredLock F86HW 18Butts as requiredLock F76Provide emergency keyHW 25Butts as requiredLock F84HW 40Butts as requiredLock F84Closer C02051HW 43Butts as requiredLock F86Closer C02011HW 62Butts as requiredLock F81 x 19 mm (3/4 inch) throw2 Automatic flush bolts2 Closers C02011Coordinator2 Armor platesPart VI: Schedule E – Room Finish, Door & Hardware -- Page 19 <strong>of</strong> 30Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> No. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]HARDWARE SETSHW 67Butts as requiredLock E16071Door pullPush-pull plate J300Closer C02051HW 69Butts as requiredLock E16071Door pullPush-pull plate J303Closer C02051Armor plateHW 81Butts as requiredLock E160712 Flush bolts2 Door pulls2 Push-pull plates J3032 Closers C02051HW 104Offset pivot set C17121Intermediate pivot C17321Door pullPush plateCloser C02051HW 108Offset pivot set C17111Intermediate pivot C17311Door pullPush plate J300Closer LCN 4010 size 6HW 68Butts as requiredLock E16071Door pullPush-pull plate J303Closer C02011HW 79Butts as requiredLock E160712 Flush bolts2 Arm pulls double base J4002 Push-pull plates J3032 Armor plates2 Closers C020112 Holders C22511HW 82Butts as requiredLock E160712 Flush bolts2 Door pulls2 Push-pull plates J3032 Closers C020112 Holders C225112 Armor platesHW 106Offset pivot set C17111Intermediate pivot C17311Lock E16071Door pullPush-pull plate J303Closer LCN 4010Armor plateHolder C22511HW 1092 Offset pivot sets C171212 Intermediate pivots C17321Lock E160712 Flush bolts2 Door pulls J 4052 Push-pulls J3032 Armor plates2 Closers LCN 4010 size 62 Holders C225111 Lead lined astragalCoordinatorPart VI: Schedule E – Room Finish, Door & Hardware -- Page 20 <strong>of</strong> 30Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> No. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]HARDWARE SETSHW 112Floor closer C160112 Push plates2 Armor plates J303Holder C21511 (Double acting)HW 124Lock (Adams-Rite) MS1861Cylinder outside thumbturn inside Pull barJ500Automatic Door OperatorHW 129Butts as requiredArmor platePush plateDoor pull J303Automatic Door OperatorsHW 1612 Pivots set C171622 Intermediate pivots C173214 Push-pull bars J5002 Door closers 4113 H cush-n-stop by LCNHW 120Butts as requiredLock E16071Door pullArmor plateAutomatic Door OperatorHW 126Butts as requiredLock E160712 Push-pull plates J3002 Door pulls2 Armor plates1 Automatic Flush BoltCoordinatorAutomatic Door OperatorHW 157Butts as required (Hospital tip)Lockset (Unican Lock Co.) 1001 - Mechanicallock with 5-button combination and 3/4 inchthrow latch boltLock E16071 with 3/4 inch throw deadbolt -Mount deadlock at 60 inches to centerline <strong>of</strong>strike from finished floor on this hardware setonlyCloser C02011Flush bolts Ives 454 by 12 inch for pairs <strong>of</strong>doors.Part VI: Schedule E – Room Finish, Door & Hardware -- Page 21 <strong>of</strong> 30Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXWainscotHardwareDepartment / Functional Area RoomCode Qty FunctionAcquisition and Materiel <strong>Management</strong> Services (AMMS)SCHEDULE E: ROOM FINISH, DOOR, AND HARDWARE SCHEDULEUnitArea sf(eachroom)Net AreasfExcludefrom NetUsable Floor Base WallCeilingCeilingHeightDoorSymbolNotesAcquistion and Distribution MMCR2 1 Holding Area, Unposted Stock 100 100 C-PUT CMU / RB CMU / GWB - EXP - 11 /12 UU-F 43Acquistion and Distribution OFA02 1 <strong>Office</strong>, Storekeeper 100 100 VCT RB CMU / GWB - AT 9'-0" 1 / 2 S 2310 ft x 10 ft Power Operated Coiling or SectionalC-PUT CMU / RB CMU / GWB - EXP - - -Acquistion and Distribution MMRP1 1 Receiving and Issue Area 100 100DoorAcquistion and Distribution DOCK1 1 Receiving and Shipping Dock 130 130 C-PUT CMU CMU - EXP - - - Covered DockCMU / GWB11 / 12 UU-C-PUT CMU / RB- EXP -Acquistion and Distribution SRHM1 1 Storage, Bio-hazard Waste 50 50SCF43Acquistion and Distribution SRE01 1 Storage, Equipment 400 400 C-PUT CMU / RB CMU / GWB - EXP - 11 / 12 V-F 43Acquistion and Distribution SHRM1 1 Storage, Flammable 50 50 C CMU / RB CMU / GWB - EXP - 26 V 43Acquistion and Distribution SRS01 1 Storage, Form / Processed Stores 150 150 C-PUT CMU / RB CMU / GWB - EXP - 26 U 4311 / 12 UU-C-PUT CMU / RB CMU / GWB - EXP -Acquistion and Distribution MMGS1 1 Storage, Medical and General 2,000 2,000F43Acquistion and Distribution SRGC1 1 Storage, Medical Gas 80 80 C-PUT CMU / RB CMU / GWB - EXP - 26 U 43Administration SEC01 1 <strong>Office</strong> Secretary and Waiting 120 120 VCT / CP RB GWB-W - AT 9'-0" 1 / 2 S 23Administration OFA02 1 <strong>Office</strong>, Chief 150 150 CP RB GWB-W - AT 9'-0" 1 / 2 S 23Administration OFA03 1 <strong>Office</strong>, Open 528 528 VCT / CP RB GWB-P - AT 9'-0" 1 / 2 S 23Administration OFA02 1 <strong>Office</strong>, Supervisor, Procurement Section 120 120 VCT / CP RB GWB-P - AT 9'-0" 1 / 2 S 23Administration OFA02 1 <strong>Office</strong>, Supervisor, Supply <strong>Management</strong> Section 100 100 VCT / CP RB GWB-P - AT 9'-0" 1 / 2 S 23Corridors VCT RB GWB-P - AT 9'-0" 1 / 2 VV-T 6Ambulatory CareHAS (MAS) RECP1 1 Central Reception Counter and Supplemental <strong>Office</strong> Equipment 150 150 VCT / CP RB GWB-P - AT 9'-0" 1 / 2 S-T 23GWB Lay-InVCT / CP RB GWB-P -HAS (MAS) OFA03 1 Interview Room / Clerical Workstation 120 120Panels9'-0" 1 / 2 S-T 23HAS (MAS) OFA02 1 <strong>Office</strong>, Agent 200 200 VCT / CP RB GWB-P - AT 9'-0" 1 / 2 S-T 23HAS (MAS) OFA02 1 <strong>Office</strong>, Compensation and Pension 120 120 VCT / CP RB GWB-P - AT 9'-0" 1 / 2 S-T 23HAS (MAS) OFA02 1 <strong>Office</strong>, Health Benefits Advisor / Patient Services Asst. 200 200 VCT / CP RB GWB-P - AT 9'-0" 1 / 2 S-T 23HAS (MAS) OFA02 2 <strong>Office</strong>, HAS Supervisor 100 200 VCT / CP RB GWB-P - AT 9'-0" 1 / 2 S-T 23HAS (MAS) OFA02 1 <strong>Office</strong>, Travel Clerk 200 200 VCT / CP RB GWB-P - AT 9'-0" 1 / 2 S-T 23HAS (MAS) OFA03 1 Workstation, Clerical 320 320 VCT / CP RB GWB-P - AT 9'-0" 1 / 2 S-T 23HAS (MAS) CASH1 1 Agent Cashier 130 130 VCT RB GWB-P - AT 9'-0" 36 S 157HAS Medical Information Section CMP01 1 AMIE System 70 70 VCT RB GWB-P - AT 9'-0" 1 / 2 S 23HAS Medical Information Section OFA02 1 <strong>Office</strong>, Assistant Chief 120 120 VCT / CP RB GWB-W - AT 9'-0" 1 / 2 S 23HAS Medical Information Section OFA02 1 <strong>Office</strong>, Medical Records 120 120 VCT / CP RB GWB-W - AT 9'-0" 1 / 2 S 23HAS Medical Information Section OFA03 2 <strong>Office</strong>, Supervisor 100 200 VCT / CP RB GWB-W - AT 9'-0" 1 / 2 S 23HAS Medical Information Section SRE01 1 Supplemental Equipment Space 75 75 VCT RB GWB-P - AT 9'-0" 1 / 2 S 23HAS Medical Information Section OFA03 2 Workstation, Medical Record Technician / Clerk 80 160 VCT RB GWB-P - AT 9'-0" 1 / 2 S 23HAS Transcription Unit (TU) OFA03 5 <strong>Office</strong>, Supervisory Transcriptionist 100 500 VCT / CP RB GWB-P - AT 9'-0" 1 / 2 S 23HAS Transcription Unit (TU) SRE01 1 Supplemental Equipment Space 70 70 VCT RB GWB-P - AT 9'-0" 1 / 2 S 23HAS Transcription Unit (TU) OFA03 1 Transcription System Controller / Records 75 75 VCT / CP RB GWB-P - AT 9'-0" 1 / 2 S 23HAS Transcription Unit (TU) OFA03 2 Workstation, Transcriptionist 64 128 VCT / CP RB GWB-P - AT 9'-0" 1 / 2 S 23HAS File Unit (FU) OFA02 1 <strong>Office</strong>, Supervisor 100 100 VCT / CP RB GWB-P - AT 9'-0" 1 / 2 S 23HAS File Unit (FU) MRS01 1 Storage, Medical Records 1,165 1,165VCT RB GWB-P - AT 9'-0" 11 / 12 SS-F 62HAS File Unit (FU) MRS01 1 Storage, Medical Records, Veteran Volunteers and Employees 50 50 VCT RB GWB-P - AT 9'-0" 11 / 12 U-F 45HAS File Unit (FU) TLTU1 2 FU Toilet 55 110 CT CT GWB-P CT 4'-0" AT 9'-0" 1 / 2 S 18HAS File Unit (FU) WRC01 1 FU Waiting Area 200 200 VCT / CP RB GWB-W - AT 9'-0" 1 / 2 S-T 23HAS File Unit (FU) WRCH1 1 Workroom 300 300 VCT RB GWB-P - AT 9'-0" 1 / 2 S 23Urgent Care NTSA4 1 Nurse / Communication Station 150 150 RSF RB GWB-W - AT 9'-0" Open -1 / 2 QQ-T /RSF RSF GWB-SC - GWB-SC 9'-0"Urgent Care BRIT1 1 Observation / Treatment: Infectious Isolation Bedroom 120 120X (ADO)791 / 2 QQ-T /RSF RSF GWB-SC - AT (SP) 9'-0"Urgent Care BRUN1 12 Observation / Treatment: Monitored Bed 100 1,200X (ADO)120Urgent Care OFA02 1 <strong>Office</strong>, Head Nurse 120 120 VCT / CP RB GWB-P - AT 9'-0" 1 / 2 S 23Urgent Care OFA03 1 <strong>Office</strong>, Physician 120 120 VCT / CP RB GWB-P - AT 9'-0" 1 / 2 S 23Urgent Care SRE01 1 Storage, Medical Equipment 120 120 VCT RB GWB-P - AT 9'-0" 11 / 12 V-F 45Urgent Care SRLW1 1 Storage, Wheelchair and Stretcher 100 100 VCT RB GWB-P - AT 9'-0" 11 / 12 V-F 45Exam / Treatment Modules (ETM) UCCL1 5 Clean Utility Room 120 600 VCT RB GWB-P - AT 9'-0" 11 / 12 V-F 45Exam / Treatment Modules (ETM) CRA02 5 Multipurpose Conference / Classroom 200 1,000 VCT / CP RB GWB-W - AT 9'-0" 1 / 2 S 23Exam / Treatment Modules (ETM) EXRG3 69 Multipurpose Exam Room 120 8,280 VCT RB GWB-P - AT 9'-0" 1 / 2 S 25Exam / Treatment Modules (ETM) TRGM1 2 Multipurpose Procedure Room 175 350 VCT RB GWB-P - AT 9'-0" 1 / 2 V 69Exam / Treatment Modules (ETM) USCL1 5 Soiled Utility Room 120 600 WSF WSF GWB-SC - GWB-SC 9'-0" 11 / 12 V-F 42______Lessor Gov't_______ Room Finish, Door and Hardware--Schedule E Page 23 <strong>of</strong> 31 ___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXWainscotHardwareRoomCode Qty FunctionSCHEDULE E: ROOM FINISH, DOOR, AND HARDWARE SCHEDULEUnitArea sf(eachroom)Net AreasfExcludefrom NetUsable Floor Base WallDepartment / Functional AreaCeilingGWB Lay-InVCT RB GWB-P -Exam / Treatment Modules (ETM) EXRG3 1 Special Purpose Dermatology Exam Room 120 120Panels9'-0" 1 / 2 S 25Exam / Treatment Modules (ETM) SRS01 5 Storage, Linen, Stretcher and Medical Equipment 100 500 VCT RB GWB-P - AT 9'-0" 11 / 12 V-F 45Exam / Treatment Modules (ETM) TLTU1 2 Toilet, Public 55 110 CT CT GWB-P CT 4'-0" AT 9'-0" 1 / 2 S 18Exam / Treatment Modules (ETM) WRC01 1 ETM Waiting Area 3,855 3,855 VCT / CP RB GWB-W - AT 9'-0" Open -Exam / Treatment Modules (ETM) RECP1 5 HAS: Clinic Module Reception Area 200 1,000 VCT / CP RB GWB-W - AT 9'-0" 1 / 2 S-T 23Exam / Treatment Modules (ETM) OFA02 1 <strong>Office</strong>, Health Benefits Advisor / Patient Services Asst. 200 200 VCT / CP RB GWB-P - AT 9'-0" 1 / 2 S 23Exam / Treatment Modules (ETM) OFA02 1 <strong>Office</strong>, Compensation and Pension 120 120 VCT / CP RB GWB-P - AT 9'-0" 1 / 2 S 23Exam / Treatment Modules (ETM) OFA03 5 NS: Cubicle, Resident Physician 64 320 VCT / CP RB GWB-P - AT 9'-0" 1 / 2 S 23Exam / Treatment Modules (ETM) MEDP1 2 NS: Medication Room 60 120 VCT RB GWB-P - AT 9'-0" 1 / 2 S 43Exam / Treatment Modules (ETM) NTSA4 2 Nurse Station (NS) 200 400 VCT RB GWB-W - AT 9'-0" Open -Exam / Treatment Modules (ETM) EXRG4 5 NS: Nurse Triage Room 100 500 VCT RB GWB-P - AT 9'-0" 1 / 2 S 25Exam / Treatment Modules (ETM) OFA02 5 NS: <strong>Office</strong>, Case Manager 120 600 VCT / CP RB GWB-P - AT 9'-0" 1 / 2 S 23Exam / Treatment Modules (ETM) OFD03 65 NS: <strong>Office</strong>, Physician / Provider 120 7,800 VCT / CP RB GWB-P - AT 9'-0" 1 / 2 S 23Exam / Treatment Modules (ETM) OFA02 15 NS: <strong>Office</strong>, Physician Extender 120 1,800 VCT / CP RB GWB-P - AT 9'-0" 1 / 2 S 23Exam / Treatment Modules (ETM) OFA02 5 NS: <strong>Office</strong>, Social Worker 120 600 VCT / CP RB GWB-P - AT 9'-0" 1 / 2 S 23Exam / Treatment Modules (ETM) OFA02 8 NS: <strong>Office</strong>, Telephone Triage Nurse 80 640 VCT / CP RB GWB-P - AT 9'-0" 1 / 2 S 23Exam / Treatment Modules (ETM) PHDS1 5 NS: Prescription Receiving Station 100 500 VCT RB GWB-W - AT 9'-0" Open -Exam / Treatment Modules (ETM) RCA01 2 NS: Storage, Crash Cart 20 40 VCT RB GWB-W - AT 9'-0" Open -Exam / Treatment Modules (ETM) TLTU1 2 NS: Toilet, Staff 55 110 CT CT GWB-P CT 4'-0" AT 9'-0" 1 / 2 S 18GWB Lay-InRSF RSF GWB-SC -Gastroenterology (GI) TRPE1 1 Screening Proctoscopy / Sigmoidoscopy Room 175 175Panels9'-0" 1 / 2 V 69Gastroenterology (GI) TLTU1 1 Toilet, Patient 55 55 CT CT GWB-P CT 4'-0" AT 9'-0" 1 / 2 S 18Dermatology (Derm) TRGS1 1 Dermatology Procedure / Treatment Room 175 175 VCT RB GWB-P - AT 9'-0" 1 / 2 S 25Dermatology (Derm) LBDE1 1 Dermatology Laboratory 100 100 VCT RB GWB-P - AT 9'-0" 1 / 2 S 23Dermatology (Derm) MEDP1 1 Dermatology Medication Prep / Storage Room 90 90 VCT RB GWB-P - AT 9'-0" 1 / 2 S 43Dermatology (Derm) OPDU1 1 Dermatology Phototherapy Treatment Room 175 175 RSF RSF GWB-P - AT 9'-0" 1 / 2 U 69Dermatology (Derm) SHWR1 1 Dermatology Phototherapy Shower Room 55 55 CT CT GWB-P CT 4'-0" AT 9'-0" 1 / 2 S 18 Full Height CT at ShowerNutrition (Dietetics) CLR02 1 Classroom 250 250 VCT / CP RB GWB-W - AT 9'-0" 1 / 2 S-T 23Nutrition (Dietetics) OFA02 3 <strong>Office</strong>, Dietician 120 360 VCT / CP RB GWB-P - AT 9'-0" 1 / 2 S 23Oncology (ONC) OPCT1 1 Chemotherapy Treatment Room 330 330 RSF RSF GWB-P - AT (SP) 9'-0" 1 / 2 W 29Oncology (ONC) TLTU1 1 Toilet, Patient 55 55 CT CT GWB-P CT 4'-0" AT 9'-0" 1 / 2 S 18Oncology (ONC) OFA02 1 <strong>Office</strong>, Data Coordiantion / Tumor Registry 120 120 VCT / CP RB GWB-P - AT 9'-0" 1 / 2 S 23Oncology (ONC) LBVP1 1 Oncology Lab 80 80 RSF RSF GWB-P - AT (SP) 9'-0" 1 / 2 S 23Womens's Health / GYN EXRG8 1 Exam Room 120 120 VCT RB GWB-P - AT 9'-0" 1 / 2 S 25Womens's Health / GYN TLTU1 1 Toilet, Patient 55 55 CT CT GWB-P CT 4'-0" AT 9'-0" 1 / 2 S 18Orthopedics (Ortho) OPCR1 1 Cast Room 175 175 RSF RSF GWB-SC - AT 9'-0" 1 / 2 V 29Orthopedics (Ortho) DR001 2 Dressing Room, Patient 35 70 VCT RB GWB-P - AT 9'-0" 1 / 2 S 18Orthopedics (Ortho) ORPC1 1 Storage, Plaster and Splints 100 100 VCT RB GWB-P - AT 9'-0" 11 / 12 V 45Clinic Based <strong>Home</strong> Care (CBHC) OFA02 1 <strong>Office</strong>, Clerical Support Staff 184 184 VCT / CP RB GWB-P - AT 9'-0" 1 / 2 S 23Clinic Based <strong>Home</strong> Care (CBHC) OFA02 1 <strong>Office</strong>, Nurse 120 120 VCT / CP RB GWB-P - AT 9'-0" 1 / 2 S 23Clinic Based <strong>Home</strong> Care (CBHC) OFD03 1 <strong>Office</strong>, Physician 120 120 VCT / CP RB GWB-P - AT 9'-0" 1 / 2 S 23Clinic Based <strong>Home</strong> Care (CBHC) OFA02 1 <strong>Office</strong>, Social Worker 120 120 VCT / CP RB GWB-P - AT 9'-0" 1 / 2 S 23Clinic Based <strong>Home</strong> Care (CBHC) OFA01 1 <strong>Office</strong>, Clerical Support Staff 120 120 VCT / CP RB GWB-P - AT 9'-0" 1 / 2 S 23Geriatric Evaluation Unit (GEU) OFA02 1 <strong>Office</strong>, Clerical Support Staff 184 184 VCT / CP RB GWB-P - AT 9'-0" 1 / 2 S 23Geriatric Evaluation Unit (GEU) OFD03 1 <strong>Office</strong>, Nurse Practitioner 120 120 VCT RB GWB-P - AT 9'-0" 1 / 2 S 25Geriatric Evaluation Unit (GEU) OFD03 1 <strong>Office</strong>, Physician 120 120 VCT / CP RB GWB-P - AT 9'-0" 1 / 2 S 23Geriatric Evaluation Unit (GEU) OFA02 1 <strong>Office</strong>, Social Worker 120 120 VCT / CP RB GWB-P - AT 9'-0" 1 / 2 S 23Patient Education (Pat EDU) LIBV1 1 Information Resource Center 400 400 VCT / CP RB GWB-W - AT 9'-0" 1 / 2 S-T 23Patient Education (Pat EDU) CLR01 1 Classroom 300 300 VCT / CP RB GWB-W - AT 9'-0" 1 / 2 S-T 23CorridorsCeilingHeightVCT RB GWB-W - AT 8'-0"Audiology and Speech PathologyAudiology (AUD) PEHS1 1 Booth, Audometric Exam 130 130 CP - - - - - - - Pre-fabricated Unit(s)Audiology (AUD) EXEN1 1 Electrophysiology Room 120 120 VCT RB GWB-P - AT 9'-0" 19 / 20 V 2519 / 20 V-TCP RB GWB-P - AT 9'-0"Audiology (AUD) OPMH1 1 Group Therapy Room 240 240M25Audiology (AUD) HAFR1 1 Hearing Aid Fabrication / Modification Room 120 120 VCT RB GWB-P - AT 9'-0" 19 / 20 V 25Audiology (AUD) TREN1 1 Immittance Room 80 80 CP RB GWB-P - AT 9'-0" 19 / 20 V-M 25Audiology (AUD) SRCH1 1 Instrument Calibration and Storage Room 140 140 VCT RB GWB-P - AT 9'-0" 19 / 20 V 25Audiology (AUD) EXOS1 1 <strong>Office</strong>, Therapy Room, Audiologist 130 130 CP RB GWB-P - AT 9'-0" 19 / 20 V-T 25Audiology (AUD) EXEN1 1 Posturography Room 150 150 CP RB GWB-P - AT 9'-0" 19 / 20 V 25Audiology (AUD) PESH4 1 Suite, Audiometric Exam 260 260 CP - - - - - - - Pre-fabricated Unit(s)Audiology (AUD) EXVE1 1 Vestibulography Room 150 150 CP RB GWB-P - AT 9'-0" 19 / 20 V 25DoorSymbol1 / 2 QQ-TOpen6 /126Notes______Lessor Gov't_______ Room Finish, Door and Hardware--Schedule E Page 24 <strong>of</strong> 31 ___ <strong>of</strong> _____ Pages-


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXWainscotHardwareDepartment / Functional AreaRoomCode Qty FunctionSCHEDULE E: ROOM FINISH, DOOR, AND HARDWARE SCHEDULEUnitArea sf(eachroom)Net AreasfExcludefrom NetUsable Floor Base WallAudiology (AUD) SRSE1 1 Equipment Area 50 50 VCT RB GWB-P - AT 9'-0" 19 / 20 V 25Audiology and Speech Pathology OFA03 1 <strong>Office</strong>, Administrative Assistant 100 100 CP RB GWB-W - AT 9'-0" 1 / 2 S 23Audiology and Speech Pathology OFA02 1 <strong>Office</strong>, Chief <strong>of</strong> Service 150 150 CP RB GWB-W - AT 9'-0" 1 / 2 S 23Audiology and Speech Pathology RECP1 1 <strong>Office</strong>, Reception / Control Clerk 120 120 CP RB GWB-W - AT 9'-0" 1 / 2 S 23Audiology and Speech Pathology SEC01 1 <strong>Office</strong>, Secretary / Clerks 120 120 CP RB GWB-W - AT 9'-0" 1 / 2 S 23Audiology and Speech Pathology TLTU1 1 Toilet, Patient 55 55 CT CT GWB-P CT 4'-0" AT 9'-0" 1 / 2 S 18Audiology and Speech Pathology WRC01 1 Waiting Area 185 185 CP RB GWB-W - AT 9'-0" Open -Speech Pathology (SP) EXOS1 1 <strong>Office</strong>, Therapy Room, Speech Pathologist 130 130 CP RB GWB-W - AT 9'-0" 1 / 2 S 23Speech Pathology (SP) WRCH1 1 Computer Assisted Traing (CAT) Workroom 120 120 CP RB GWB-W - AT 9'-0" 19 / 20 V-T 25Speech Pathology (SP) OPMH1 1 Group Therapy Room 225 225CeilingCeilingHeightCP RB GWB-P - AT 9'-0"Speech Pathology (SP) EXOS1 1 Speech Analysis Laboratory 200 200 CP RB GWB-P - AT 9'-0" 19 / 20 V-T 25Corridor CP RB GWB-P - AT 9'-0" 19 / 20 V-T 25DoorSymbol19 / 20 V-TM25NotesCanteen1 / 2 SS-TCP RB GWB-P - AT 9'-0"Canteen Service FSDC1 1 Canteen - 0ADO124Canteen Service SL001 1 Staff Lunch / Break Room 480 480 VCT RB GWB-W - AT 9'-0" 1 / 2 SS-T 82Canteen Service BX001 1 Vending Machine Area and Seating 360 360 VCT RB GWB-W - AT 9'-0" 1 / 2 T 1Cardiovascular Laboratories (Cardiology)Cardiology OPEC1 1 ECG Testing Cubicle 100 100 VCT RB GWB-P - AT 9'-0" 1 / 2 S 25Cardiology OPPE1 1 Echocardiography Exam Room 200 200 VCT RB GWB-P - AT 9'-0" 1 / 2 V 67Cardiology OPTM1 1 Exercise Room (Stress Lab Facility) 240 240 VCT RB GWB-P - AT 9'-0" 1 / 2 V 67Cardiology OPHM1 1 Pacemaker / Holter Monitor Room 120 120 VCT RB GWB-P - AT 9'-0" 1 / 2 S-T 67Clinic <strong>Management</strong>Clinic <strong>Management</strong> CRA01 1 Conference Room 300 300 CP RB GWB-W - AT 9'-0" 1 / 2 S 23Clinic <strong>Management</strong> OFC01 1 <strong>Office</strong>, Chief Administrative <strong>Office</strong>r 200 200 CP RB GWB-W - AT 9'-0" 1 / 2 S 23Clinic <strong>Management</strong> OFA02 2 <strong>Office</strong>, Clinic <strong>Management</strong> Support Staff 100 200 CP RB GWB-W - AT 9'-0" 1 / 2 S 23Clinic <strong>Management</strong> OFA02 2 <strong>Office</strong>, Medical Administrative <strong>Office</strong>r (MAO) 120 240 CP RB GWB-W - AT 9'-0" 1 / 2 S 23Clinic <strong>Management</strong> SEC01 1 <strong>Office</strong>, Secretary and Waiting 120 120 CP RB GWB-W - AT 9'-0" 1 / 2 S-T 23Clinic <strong>Management</strong> SEC01 2 <strong>Office</strong>, Secretary to the MAO and Waiting 120 240 CP RB GWB-W - AT 9'-0" 1 / 2 S 23Clinic <strong>Management</strong> SRSE1 1 Support Equipment 150 150 VCT RB GWB-P - AT 9'-0" 1 / 2 S 13Clinic <strong>Management</strong> TLTU1 1 Toilet, Staff 50 50 CT CT GWB-P CT 4'-0" AT 9'-0" 1 / 2 S 18Corridors CP RB GWB-W - AT 8'-0" 1 / 2 V-T 23DentalDental DNTG2 1 Combined Dental Hygiene Operatory 150 150 RSF RSF GWB-SC - AT (SP) 9'-0" Open -Dental CRA01 1 Conference Room 220 220 VCT / CP RB GWB-W - AT 9'-0" 1 / 2 S-T 23Dental DNPL1 1 Dental Prosthetic Laboratory 100 100 RSF RSF GWB-SC - AT (SP) 9'-0" 1 / 2 S-T 69Dental DNSC2 1 Instrument Preparation and Sterilization Room 90 90 RSF RSF GWB-SC - AT (SP) 9'-0" 1 / 2 U-T 69Dental LCCL1 1 Linen Room and Clean SPD Cart 80 80 VCT RB GWB-SC CT 4'-0" AT 9'-0" 11 / 12 V-F 45Dental LR002 1 Locker Room / Changing Area - 0 VCT RB GWB-P - AT 9'-0" 1 / 2 S 1Dental MECH1 1 Mechanical Room 80 80C-EPY RB GWB-P - EXP - 11 / 12 VV-F 43Dental OFA02 1 <strong>Office</strong>, Administrative Assistant 100 100 VCT / CP RB GWB-W - AT 9'-0" 1 / 2 S 23Dental OFC01 1 <strong>Office</strong> Chief 150 150 VCT / CP RB GWB-W - AT 9'-0" 1 / 2 S 23Dental OFD03 5 <strong>Office</strong>, Dentist 120 600 VCT / CP RB GWB-W - AT 9'-0" 1 / 2 S 23Dental SEC01 1 <strong>Office</strong>, Secretary / Reception / Files / Additional Clerk 360 360 VCT / CP RB GWB-W - AT 9'-0" 1 / 2 S 23Dental DNTS1 1 Oral Surgery Room 150 150 RSF RSF GWB-SC - AT (SP) 9'-0" 1 / 2 QQ 112Dental TLTU1 1 Patient Toilet 50 50 CT CT GWB-P CT 4'-0" AT 9'-0" 1 / 2 S 18Dental DNTR1 1 Recovery Room 110 110 RSF RSF GWB-P - AT 9'-0" 1 / 2 V 67Dental LCSL1 1 Soiled SPD Cart Holding 60 60 RSF RSF GWB-SC CT 4'-0" AT 9'-0" 11 / 12 V-F 4511 / 12 SS-FVCT RB GWB-P - AT 9'-0"4511 / 12 V-FDental SRE01 1 Storage Room 80 80Dental WRC01 1 Waiting Area 155 155 VCT / CP RB GWB-W - AT 9'-0" Open -Dental DNXD1 1 X-Ray Area 230 230 RSF RSF GWB-SC - AT (SP) 9'-0" Open -Education AreasEducation Areas CRA03 1 Educational Conference Room 1,050 1,050 VCT / CP RB GWB-W - AT 9'-0" 1 / 2 U-T 23Education Areas OFA03 1 Instruction Area 250 250 VCT / CP RB GWB-W - AT 9'-0" 1 / 2 U-T 23______Lessor Gov't_______ Room Finish, Door and Hardware--Schedule E Page 25 <strong>of</strong> 31 ___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXWainscotHardwareDepartment / Functional Area RoomCode Qty FunctionElectro-Encephalography Laboratory (EEG)SCHEDULE E: ROOM FINISH, DOOR, AND HARDWARE SCHEDULEUnitArea sf(eachroom)Net AreasfExcludefrom NetUsable Floor Base WallEEG OPEE1 2 EEG Exam Room 120 240 VCT RB GWB-P - AT 9'-0" 1 / 2 V-M 25EEG OPEE2 1 EEG Instrument and Work Room 205 205 VCT RB GWB-P - AT 9'-0" 1 / 2 U-T 67EEG OFA02 2 <strong>Office</strong>, Technician 100 200 VCT RB GWB-P - AT 9'-0" 1 / 2 S-T 67EEG MRS01 1 Storage, EEG Records 150 150 VCT RB GWB-P - AT 9'-0" 1 / 2 U-T 13CeilingCeilingHeightDoorSymbolNotesDigestive Diseases Program--EndoscopyEndoscopy DR001 4 Changing Area, Patient 60 240 VCT RB GWB-P - AT 9'-0" 1 / 2 S 18Endoscopy RROP1 2 Cubicle, Patient Recovery 100 200 VCT RB GWB-P - AT 9'-0" 1 / 2 W 67Endoscopy XVC01 1 Dictation / Viewing Room 120 120 VCT / CP RB GWB-P - AT 9'-0" 1 / 2 S 23GWB Lay-InRSF RSF GWB-SC -Endoscopy TREE1 2 EGD Procedure Room 300 600Panels9'-0" 1 / 2 V 69Endoscopy JANC1 1 Housekeeping Aides Closet (HAC) 40 40 CT CT GWB-EPY CT 4'-0" AT (SP) 9'-0" 1 / 2 T 13Endoscopy NSTA4 1 Nurse Station 100 100 VCT RB GWB-W - AT 9'-0" Open -Endoscopy 0FD03 1 <strong>Office</strong>, GI Assistant 120 120 VCT / CP RB GWB-P - AT 9'-0" 1 / 2 S 23Endoscopy RECP1 1 Reception Area 120 120 VCT / CP RB GWB-W - AT 9'-0" 1 / 2 S 23Endoscopy USCL2 1 Scopes Clean-up, Sterilization and Storage Room 120 120 WSF WSF GWB-SC - AT (SP) 9'-0" 1 / 2 S 23Endoscopy RCA01 1 Storage, Crash Cart 20 20 VCT RB GWB-P - AT 9'-0" Open -Endoscopy TLTU1 3 Toilet, Patient 50 150 CT CT GWB-P CT 4'-0" AT 9'-0" 1 / 2 S 18Endoscopy UCCL1 1 Utility Room, Clean 100 100 VCT RB GWB-P - AT 9'-0" 11 / 12 V-F 45Endoscopy USCL1 1 Utility Room, Soiled 80 80 WSF WSF GWB-SC - GWB-SC 9'-0" 11 / 12 V-F 42Endoscopy WRC01 1 Waiting Area 150 150 VCT / CP RB GWB-W - AT 9'-0" Open -EngineeringEngineering BMER1 1 Biomedical Engineering Repair Shop 200 200 VCT RB GWB-P - AT 9'-0" 1 / 2 SS-T 82Environmental <strong>Management</strong> (EMS)EMS JANC1 7 Housekeeping Aids Closet (HAC) 40 280 CT CT GWB-EPY CT 4'-0" AT (SP) 9'-0" 1 / 2 T 13 One per 13,000 nsf; distribute throughout OPCEMS SHRHM1 1 Infectious / Hazardous Waste 120 120 WSF WSF GWB-SC - GWB-SC 9'-0" 11 / 12 V-F 42EMS OFA02 1 <strong>Office</strong>, Chief 150 150 VCT / CP RB GWB-W - AT 9'-0" 1 / 2 S 23EMS SEC01 1 <strong>Office</strong>, Secretary and Waiting 120 120 VCT / CP RB GWB-P - AT 9'-0" 1 / 2 S 23EMS UTC01 1 Recyclable Waste 120 120 C-EPY RB GWB-P - EXP - 10 X 43EMS LCCL1 1 Storage, Clean Linen Cart 100 100VCT RB GWB-SC CT 5'-0" AT (SP) 9'-0" 11 / 12 SS-F 43EMS SRSE1 1 Storage, Environmental <strong>Management</strong> Supplies / Large Equipment 750 750 VCT RB GWB-P - AT 9'-0" 11 / 12 V-F 69EMS LCSL1 1 Storage, Soiled Linen Cart 100 100VCT RB GWB-SC CT 4'-0" AT (SP) 9'-0" 11 / 12 SS-F 43Eye ClinicEye Clinic TREY1 1 Exam / Treatment Room 130 130 VCT RB GWB-P/W - AT 9'-0" 1 / 2 V 25Eye Clinic EYFD1 1 Fitting and Dispensing Room 120 120 VCT RB GWB-P/W - AT 9'-0" 1 / 2 V 25Eye Clinic OFA02 1 <strong>Office</strong>, Blind Rehabilitation (VIST), Counselor 120 120 VCT / CP RB GWB-P/W - AT 9'-0" 1 / 2 V 23Eye Clinic OFD03 6 <strong>Office</strong>, Eye Care Provider 120 720 VCT / CP RB GWB-P/W - AT 9'-0" 1 / 2 V 23Eye Clinic EYVS1 1 Photography Room 150 150 VCT RB GWB-P/W - AT 9'-0" 1 / 2 V 25Eye Clinic RECP1 1 Reception Area - 0 VCT / CP RB GWB-P - AT 9'-0" 1 / 2 S-T 23Eye Clinic EYVF1 1 Visual Fields Room 130 130 VCT RB GWB-P/W - AT 9'-0" 1 / 2 V 25Eye Clinic WRC01 1 Waiting Area (Dilation) 60 60 VCT / CP RB GWB-W - AT 9'-0" Open -LobbyLobby OFA02 1 Escort Room 150 150 VCT RB GWB-P - AT 9'-0" 1 / 2 T 23Lobby RECP3 1 Information Desk 100 Finishes 100 to be selected on basis <strong>of</strong> requirements and costLobby LOB01 1 Public Telephones 30 Finishes 30 to be selected on basis <strong>of</strong> requirements and costLobby SRLW1 1 Storage, Wheelchair 100 100 VCT RB GWB-P - AT 9'-0"Lobby TLTU1 1 Toilet, Female, Public 50 50 CT CT GWB-P CT 4'-0" AT 9'-0" 1 / 2 S 14 Use HW Set 1 for Multi-use TolietsLobby TLTU1 1 Toilet, Male, Public 50 50 CT CT GWB-P CT 4'-0" AT 9'-0" 1 / 2 S 14 Use HW Set 1 for Multi-use TolietsLobby WRC01 1 Waiting Area 200 Finishes 200 to be selected on basis <strong>of</strong> requirements and costEMS: Lockers, Lounges, Toilets and Showers (LLTS)EMS: LLTS LR002 1 Locker Room 1,500 1,500 VCT RB GWB-P - AT 9'-0" 1 / 2 S 1EMS: LLTS TLTS1 1 Shower, Female Staff 50 50 CT CT GWB-EPY CT 4'-0" PCP-EPY 9'-0" 1 / 2 S 1 Full Height CT at Shower StallEMS: LLTS TLTS1 1 Shower, Male Staff 50 50 CT CT GWB-EPY CT 4'-0" PCP-EPY 9'-0" 1 / 2 S 1 Full Height CT at Shower StallEMS: LLTS TLTU1 10 Toilet, Staff 50 500 CT CT GWB-P CT 4'-0" AT 9'-0" 1 / 2 S 18______Lessor Gov't_______ Room Finish, Door and Hardware--Schedule E Page 26 <strong>of</strong> 31 ___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXDepartment / Functional Area RoomCode Qty FunctionHealthcare Adminstration (HAS)SCHEDULE E: ROOM FINISH, DOOR, AND HARDWARE SCHEDULEWainscotHardwareUnitArea sf(eachroom)Net AreasfExcludefrom NetUsable Floor Base WallFee Services Section SRSE1 1 Supplemental Equipment Space 260 260 VCT RB GWB-P - AT 9'-0" 1 / 2 S 13Fee Services Section OFA02 8 Workstation, Clerical 80 640 VCT / CP RB GWB-W - AT 9'-0" 1 / 2 S-T 25Fee Services Section OFA02 2 Workstation, Supervisor 100 200 VCT / CP RB GWB-W - AT 9'-0" 1 / 2 S 23Medical Care Cost Revoery (MCCR) SRSE1 1 Supplemental Equipment Space 140 140 VCT RB GWB-P - AT 9'-0" 1 / 2 S-T 13Medical Care Cost Revoery (MCCR) OFA02 4 Workstation, Clerical 80 320 VCT / CP RB GWB-W - AT 9'-0" 1 / 2 S-T 25Medical Care Cost Revoery (MCCR) OFA02 2 Workstation, Supervisor 100 200 VCT / CP RB GWB-W - AT 9'-0" 1 / 2 S 23<strong>Office</strong> <strong>of</strong> the Chief OFA02 3 <strong>Office</strong> ,Administrative Assistant 100 300 VCT / CP RB GWB-W - AT 9'-0" 1 / 2 S 23<strong>Office</strong> <strong>of</strong> the Chief OFA02 2 <strong>Office</strong>, Assistant Chief 120 240 VCT / CP RB GWB-W - AT 9'-0" 1 / 2 S 23<strong>Office</strong> <strong>of</strong> the Chief OFC02 1 <strong>Office</strong>, Chief 150 150 VCT / CP RB GWB-W - AT 9'-0" 1 / 2 S 23<strong>Office</strong> <strong>of</strong> the Chief SEC01 1 <strong>Office</strong>, Secretary and Waiting 440 440 VCT / CP RB GWB-W - AT 9'-0" 1 / 2 S-T 25<strong>Office</strong> Operation (Support Services) RPR01 1 Copy Room 150 150 VCT / CP RB GWB-P - AT 9'-0" 1 / 2 U-T 25CeilingCeilingHeightDoorSymbolNotesMental HealthAdministration OPMH1 3 Group Therapy Room 300 f VCT RB GWB-P - AT 9'-0" 1 / 2 SS-T 62Administration OFA02 1 <strong>Office</strong>, Director 150 150 CP RB GWB--W - AT 9'-0" 1 / 2 S 23Administration SEC01 1 <strong>Office</strong>, Secretary / Clerical 248 248 CP RB GWB--W - AT 9'-0" 1 / 2 S-T 23Administration RECP1 1 Reception / Control Unit 120 120 VCT / CP RB GWB--W - AT 9'-0" 1 / 2 S 23Administration TLTU1 1 Toilet, Patient Female 50 50 CT CT GWB-P CT 4'-0" AT 9'-0" 1 / 2 S 18Administration TLTU1 1 Toilet Patient Male 50 50 CT CT GWB-P CT 4'-0" AT 9'-0" 1 / 2 S 18Administration TLTU1 1 Toilet, Staff 50 50 CT CT GWB-P CT 4'-0" AT 9'-0" 1 / 2 S 18Day Treatment Center OFDC1 1 <strong>Office</strong>, Chief 150 150 CP RB GWB--W - AT 9'-0" 1 / 2 S 23Day Treatment Center OFDC1 5 <strong>Office</strong>, Counseling Staff 120 600 CP RB GWB--W - AT 9'-0" 1 / 2 S 23Day Treatment Center FSCD1 1 Social Activities / Dining / Multipurpose 500 500 VCT RB GWB-P - AT 9'-0" 1 / 2 SS-T 81Day Treatment Center FSNP1 1 Social Activities Space / Kitchen 150 150 VCT RB GWB-W - AT (SP) 9'-0" 1 / 2 V-T 69Day Treatment Center SRS01 1 Social Activities Space / Storage 140 140 VCT RB GWB-P - AT 9'-0" 11 / 12 S-F 43Mental Health Clinic OPMH3 1 Bi<strong>of</strong>eedback Control Room / Tech <strong>Office</strong> 120 120 VCT RB GWB-P - AT 9'-0" 1 / 2 U 25Mental Health Clinic OPMH3 1 Bi<strong>of</strong>eedback Treatment Room 120 120 VCT RB GWB-P - AT 9'-0" 1 / 2 U 25Mental Health Clinic EXRG3 1 Exam / Treatment Room 120 120 VCT RB GWB-P - AT 9'-0" 1 / 2 U 25Mental Health Clinic OFDC1 1 <strong>Office</strong>, Chief 150 150 CP RB GWB--W - AT 9'-0" 1 / 2 S 23Mental Health Clinic OFDC1 30 <strong>Office</strong>, Counseling Staff 120 3,600 CP RB GWB--W - AT 9'-0" 1 / 2 S 23Methadone Maintenance Program MEDP1 1 Medication / Treatment Room 120 120 VCT RB GWB-P - AT 9'-0" 1 / 2 U 25Methadone Maintenance Program PHDS1 1 Methadone Dispensing Pharmacy 175 175 VCT RB GWB-P - GWB-P 9'-0" 30 U 157Methadone Maintenance Program OFD03 1 <strong>Office</strong> / Exam Room, Nurse Practitioner 130 130 VCT RB GWB-P - AT 9'-0" 1 / 2 S 25Methadone Maintenance Program SSV01 1 Storage / Vault 50 50 VCT RB GWB-P - AT 9'-0" 30 U 157Methadone Maintenance Program TLTU1 1 Toilet, Urine Specimen Collection 50 50 CT CT GWB-P CT 4'-0" AT 9'-0" 1 / 2 S 18Methadone Maintenance Program WRC01 1 Waiting Area 150 150 VCT / CP RB GWB--W - AT 9'-0" Open -Occupational Therapy OTDL1 1 Basic Clinic 650 650 VCT RB GWB-P - AT 9'-0" 1 / 2 SS-TOccupational Therapy SRS01 1 Storage 100 100 VCT RB GWB-P - AT 9'-0" 11 / 12 S-F 43Substance Abuse Clinic OFDC1 1 <strong>Office</strong>, Chief 150 150 VCT / CP RB GWB--W - AT 9'-0" 1 / 2 S 23Substance Abuse Clinic OFD03 1 <strong>Office</strong>, Nurse / Pharmacist 120 120 VCT / CP RB GWB--W - AT 9'-0" 1 / 2 S 23Substance Abuse Clinic OFD03 1 <strong>Office</strong>, Physician 120 120 VCT / CP RB GWB--W - AT 9'-0" 1 / 2 S 23Substance Abuse Clinic OFDC1 1 <strong>Office</strong>, Psychologist 120 120 VCT / CP RB GWB--W - AT 9'-0" 1 / 2 S 23Substance Abuse Clinic SEC01 1 <strong>Office</strong>, Secretary / Clerical 184 184 VCT / CP RB GWB--W - AT 9'-0" 1 / 2 S-T 23Substance Abuse Clinic OFDC1 1 <strong>Office</strong>, Social Worker 120 120 VCT / CP RB GWB--W - AT 9'-0" 1 / 2 S 23Substance Abuse Clinic OFA02 1 <strong>Office</strong> Statistical Clerk 80 80 VCT / CP RB GWB--W - AT 9'-0" 1 / 2 S 23Substance Abuse Clinic OFDC1 1 Rehabilitation Counselor 1,120 1,120 VCT / CP RB GWB--W - AT 9'-0" 1 / 2 S 23Substance Abuse Clinic SRS01 1 Utility and Storage 120 120 VCT RB GWB-P - AT 9'-0" 11 / 12 S-F 43Pathology and Laboratory Medicine (PLM)Laboratories LBVP1 1 Blood Specimen Collection Room 120 120 VCT RB GWB-P - AT 9'-0" 1 / 2 V-T 25Laboratories LMCH1 1 Clinical Chemistry 400 400 VCT RB GWB-P - AT 9'-0" 1 / 2 V-T 67Laboratories LMM03 1 Clinical Microbiology 150 150 VCT RB GWB-P - AT 9'-0" 3 / 4 V-T 67Laboratories LBSM1 1 Sterilization and Solution Preparation Room 100 100 RSF RSF GWB-SC - GWB-SC 9'-0" 1 / 2 V-T 67Laboratories SRS01 1 Storage, Bulk 200 200 VCT RB GWB-P - AT 9'-0" 11 / 12 V-F 45Laboratories SRR02 1 Storage, Refrigerated 50 50 - - - - - - - - Pre-fabricated Unit(s)Laboratories TLTU1 1 Toilet, Urine Specimen Collection 50 50 CT CT GWB-P CT 4'-0" AT 9'-0" 1 / 2 S 18Laboratories WRC01 1 Waiting Area, Patient - 0 VCT RB GWB-W - AT 9'-0" Open -PLM OFA02 1 <strong>Office</strong>, Chief Medical Technologist 120 120 VCT RB GWB-W - AT 9'-0" 1 / 2 S 23PLM OFD03 1 <strong>Office</strong>, Pathologist and Microscope Area 120 120 VCT RB GWB-W - AT 9'-0" 1 / 2 S 23PLM SEC01 1 <strong>Office</strong>, Secretary / Clerical 440 440 VCT RB GWB-W - AT 9'-0" 1 / 2 S 23PharmacyNon-Secure Areas OFDC2 1 Consultation Room 100 100 VCT / CP RB GWB--W - AT 9'-0" 1 / 2 S 23______Lessor Gov't_______ Room Finish, Door and Hardware--Schedule E Page 27 <strong>of</strong> 31 ___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXWainscotHardwareDepartment / Functional AreaRoomCode Qty FunctionSCHEDULE E: ROOM FINISH, DOOR, AND HARDWARE SCHEDULEUnitArea sf(eachroom)Net AreasfExcludefrom NetUsable Floor Base WallNon-Secure Areas OFA03 1 Prescription Receiving 140 140 VCT RB GWB--W - AT 9'-0" -- -Non-Secure Areas WRC01 1 Waiting Area 240 240 VCT / CP RB GWB--W - AT 9'-0" Open -Secure Areas OFA03 1 Data Processing Space 144 144 VCT RB GWB--P - AT 9'-0" -- -Secure Areas PHOD2 1 Dispensing 405 405 VCT RB GWB--P - AT 9'-0" -- -Secure Areas PHBS1 1 Drug Receiving, Breakdown and Verification Area 145 145 VCT RB GWB--P - AT 9'-0" -- -Secure Areas PHMP1 1 Extemporaneous Compounding 80 80 VCT RB GWB--P - AT 9'-0" -- -Secure Areas PHOD1 1 Filling and Assembly 180 180 VCT RB GWB--P - AT 9'-0" -- -Secure Areas PHMP2 1 Mail Out 180 180 VCT RB GWB--P - AT 9'-0" -- -Secure Areas OFA02 1 <strong>Office</strong>, Assistant / Associate Chief 120 120 VCT / CP RB GWB--W - AT 9'-0" 1 / 2 S 23Secure Areas OFA02 1 <strong>Office</strong>, Chief 150 150 VCT / CP RB GWB--W - AT 9'-0" 1 / 2 S 23Secure Areas OFA02 2 <strong>Office</strong>, Drug Receiving: Inventory Control / Stock Manager 80 160 VCT / CP RB GWB--W - AT 9'-0" 1 / 2 S 23 Mortise Lock F04Secure Areas SEC01 1 <strong>Office</strong>, Secretary and Waiting 120 120 VCT / CP RB GWB--W - AT 9'-0" 1 / 2 S 23Secure Areas OFA02 3 <strong>Office</strong>, Supervisory Pharmacist 100 300 VCT / CP RB GWB--W - AT 9'-0" 1 / 2 S 23Secure Areas PHIV3 1 Oncology: Preparation Area 180 180Secure Areas XXYYC 1 Oncology: Preparation Area Anteroom 35 35CeilingCeilingHeightWSF WSF Special - 9'-0"WSF WSF Special - 9'-0"DoorSymbol2 T-MADO2 T-MADONotes129 Clean Room construction to comply with USP 797129 Clean Room construction to comply with USP 797Secure Areas PHBS2 1 Oncology: Storage and Clean / Decontamination Area 60 60Secure Areas XXYYC 1 Oncology: Clean CorridorWSF WSF Special - 9'-0" 36 T 157 Clean Room construction to comply with USP 797WSF WSF Special - 9'-0"2 T-MADO129 Clean Room construction to comply with USP 797Secure Areas JANC1 1 Oncology: Housekeeping Aids Closet HAC 40 40WSF WSF Special - 9'-0" 2 T-M 13 Clean Room construction to comply with USP 797Secure Areas OFA03 1 Oncology: Reference Area 80 80 VCT RB GWB--P - AT 9'-0" 1 / 2 S 23Secure Areas PHMP2 1 Prepackaging 135 135 VCT RB GWB--P - AT 9'-0" -- -Secure Areas SRR01 1 Refrigeration / Freezer Area 88 88 VCT RB GWB--P - AT 9'-0" -- -Secure Areas PHOD2 1 Storage, Active 450 450 VCT RB GWB--P - AT 9'-0" -- -Secure Areas SSS01 1 Storage, Controlled Substance / Secured Dispensing 150 150 VCT RB GWB--P - GWB-P 9'-0" 30 U 157Secure Areas SRHM1 1 Storage, Flammable 30 30 VCT RB GWB--P - AT 9'-0" 11 / 12 S 157Secure Areas SRCS1 1 Storage, Prosthetic and Medical Supplies 175 175 VCT RB GWB--P - AT 9'-0" 11 / 12 S 45 Mortise Lock F04Secure Areas TLTU1 1 Toilet, Staff 50 50 CT CT GWB-P CT 4'-0" AT 9'-0" 1 / 2 S 18Physical Medicine and Rehabiltation (PMR)Occupational Therapy (OT) OTGC1 1 Treatment Clinic 600 600 VCT RB GWB--P - AT 9'-0" 1 / 2 V-T 25Occupational Therapy (OT) SRE01 1 Storage, Equipment 100 100 VCT RB GWB--P - AT 9'-0" 11 / 12 S 45Occupational Therapy (OT) OFA02 1 Clinic <strong>Office</strong> 120 120 VCT RB GWB--P - AT 9'-0" 3 / 4 S-T 23Physical Therapy (PT) DR001 1 Dressing Room 50 50 VCT RB GWB--P - AT 9'-0" 1 / 2 S 18Physical Therapy (PT) TLTU1 1 Toilet, Patient 55 55 CT CT GWB-P CT 4'-0" AT 9'-0" 1 / 2 S 18Physical Therapy (PT) SRE01 1 Storage, Equipment 75 75 VCT RB GWB--P - AT 9'-0" 11 / 12 S 45Physical Therapy (PT) PTEA1 1 Treatment Exercise Area 1,000 1,000 VCT RB GWB--P - AT 9'-0" 1 / 2 V-T 25Physical Therapy (PT) UTLC1 1 Utility Room, Clean 100 100 VCT RB GWB-P - AT 9'-0" 11 / 12 V-F 45PMR WRC01 1 Waiting Area 60 60 VCT RB GWB--P - AT 9'-0" 1 / 2 V-T 25Police and SecurityPolice and Security CROP1 1 Holding Room 60 60 VCT RB CMU-P / PCP-P - GWB-P 9'-0" 22 T-A 10 Security Mesh (not lath) at PCP and GWBPolice and Security OPMH4 1 Operations Room 120 120 VCT RB GWB--P - AT 9'-0" 1 / 2 S-T 23Prosthetics and Sensory AidsProsthetics and Sensory Aids OFA02 1 <strong>Office</strong>, Chief 150 150 VCT / CP RB GWB--W - AT 9'-0" 1 / 2 S 23Prosthetics and Sensory Aids OFA02 1 <strong>Office</strong>, Dispensing Prosthetic Clerk 312 312 VCT / CP RB GWB-P - AT 9'-0" 1 / 2 S-T 23Prosthetics and Sensory Aids OFA02 1 <strong>Office</strong>, Prosthetic Representative 120 120 VCT / CP RB GWB--W - AT 9'-0" 1 / 2 S 23Prosthetics and Sensory Aids SEC01 1 <strong>Office</strong>, Secretary and Waiting 120 120 VCT / CP RB GWB--W - AT 9'-0" Open -Prosthetics and Sensory Aids SRCS1 1 Prosthetic Appliance Storage: Mailing Room 80 80 VCT RB GWB-P - AT 9'-0" 1 / 2 S 23Prosthetics and Sensory Aids SRCS1 1 Prosthetic Appliance Storage: Storage Room 150 150 VCT RB GWB-P - AT 9'-0" 11 / 12 V-F 45Prosthetics and Sensory Aids RECP1 1 Reception and Waiting Area 60 60 VCT RB GWB--W - AT 9'-0" 3 / 4 U-T 23Pulmonary Medicine (PM)Pulmonary Medicine (PM) OPPF5 1 Exercise Room 240 240 VCT RB GWB--W - AT 9'-0" 1 / 2 V-T 69Pulmonary Medicine (PM) TRPE2 1 Special Procedures / Bronchoscopy Room 240 240 VCT RB GWB--W - AT (SP) 9'-0" 1 / 2 V-T 69Pulmonary Medicine (PM) OPPF1 1 Ventilatory Test Room, Spirometry 312 312 VCT RB GWB--W - AT 9'-0" 1 / 2 V-T 69RadiologyRadiology XDCS1 1 Chest Room - Dedicated 250 250 VCT RB GWB-P - AT 9'-6" 15 X 106Radiology XVC01 1 Common Viewing Room 150 150 VCT / CP RB GWB--W - AT 9'-0" 1 / 2 S 23______Lessor Gov't_______ Room Finish, Door and Hardware--Schedule E Page 28 <strong>of</strong> 31 ___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXWainscotHardwareDepartment / Functional AreaRoomCode Qty FunctionSCHEDULE E: ROOM FINISH, DOOR, AND HARDWARE SCHEDULEUnitArea sf(eachroom)Net AreasfExcludefrom NetUsable Floor Base WallRadiology XCTS1 1 Computed Tomography: Computer / Power Equipment Room 120 120 AF RB GWB-P - AT 9'-6" 1 / 2 T 25Radiology XCTC1 1 Computed Tomography: Control Room 120 120 AF RB GWB-P - AT 9'-6" 15 T 104Radiology XCTS1 1 Computed Tomography: Scanning Room 400 400 VCT RB GWB-P - AT 9'-6" 15 X 106Radiology SRE01 1 Computed Tomography: Storage Room 80 80 VCT RB GWB-P - AT 9'-0" 11 / 12 T 45Radiology TLTU1 1 Computed Tomography: Toilet, Patient 50 50 CT CT GWB-P CT 4'-0" AT 9'-0" 1 / 2 S 18Radiology DR001 7 Dressing Room 35 245 VCT RB GWB--P - AT 9'-0" 1 / 2 S 18Radiology XDR01 1 General Purpose Radiology Room 300 300 VCT RB GWB-P - AT 9'-6" 15 X 106Radiology JANC1 1 Housekeeping Aides Closet - HAC 40 40 CT CT GWB-EPY CT 4'-0" AT (SP) 9'-0" 1 / 2 T 13Radiology XDM01 1 Mammography Room 160 160 VCT RB GWB--P - AT 9'-0" 1 / 2 U 25Radiology OFDR1 1 <strong>Office</strong>, Chief Radiologist 150 150 VCT / CP RB GWB--W - AT 9'-0" 1 / 2 S 23Radiology OFA02 5 <strong>Office</strong>, Pr<strong>of</strong>essional, Non Physician 120 600 VCT / CP RB GWB--W - AT 9'-0" 1 / 2 S 23Radiology OFA03 1 <strong>Office</strong>, Reception 280 280 VCT / CP RB GWB--W - AT 9'-0" 1 / 2 S-T 23Radiology SEC01 1 <strong>Office</strong>, Secretary and Waiting 120 120 VCT / CP RB GWB--W - AT 9'-0" 1 / 2 S-T 23Radiology OFDR1 3 <strong>Office</strong>, Staff Radiologist 120 360 VCT / CP RB GWB--W - AT 9'-0" 1 / 2 S 23Radiology XDRF1 1 Radiographic / Fluoroscopic (R/F) Room 320 320 VCT RB GWB-P - AT 9'-6" 15 X 106Radiology TLTU1 1 Ultrasound: Toilet, Patient 50 50 CT CT GWB-P CT 4'-0" AT 9'-0" 1 / 2 S 18Radiology XDUS1 1 Ultrasound Room 180 180 VCT RB GWB--P - AT 9'-0" 1 / 2 U 25Radiology UCCL1 1 Utility Room, Clean 100 100 VCT RB GWB-P - AT 9'-0" 11 / 12 V-F 45Radiology USCL1 1 Utility Room, Soiled 80 80 WSF WSF GWB-SC - GWB-SC 9'-0" 11 / 12 V-F 42Radiology WRC01 1 Waiting Area 395 395 VCT / CP RB GWB--W - AT 9'-0" 1 / 2 U 23Radiology SRLW1 7 Waiting, Wheelchair and Stretcher 25 175 VCT / CP RB GWB--W - AT 9'-0" Open -CeilingCeilingHeightDoorSymbolNotesService OrganizationsService Organizations SEC01 2 <strong>Office</strong>, Secretary 80 160 VCT / CP RB GWB-W - AT 9'-0" 1 / 2 S 23Service Organizations OFA02 4 <strong>Office</strong>, Service Organization Representative, PT 120 480 VCT / CP RB GWB-W - AT 9'-0" 1 / 2 S 23Service Organizations OFA02 2 <strong>Office</strong>, Service Organization Representative, FT 120 240 VCT / CP RB GWB-W - AT 9'-0" 1 / 2 S 23Service Organizations SRS01 1 Storage 40 40 VCT RB GWB-P - AT 9'-0" 1 / 2 S 13Supply, Processing and Distribution (SPD)SPD: Clean OFA03 1 Dispatch Area 94 94VCT RB GWB-SC - AT 9'-0"SPD: Clean JANC1 1 Housekeeping Aides Closet (HAC) 40 40 CT CT GWB-EPY CT 4'-0" AT (SP) 9'-0" 1 / 2 T 132 UU-T / 82 /WSF WSF GWB-SC - GWB-SC 9'-0"SPD: Clean CSIA2 1 Preparation Area 300 30012 UU-F 1612 UU-T / 82 /VCT RB GWB-SC - AT (SP) 9'-0"SPD: Clean ORSS1 1 Storage, Bulk and Receiving 80 8012 UU-F 1612 SS-T /VCT RB GWB-SC - AT (SP) 9'-0"SPD: Clean SRSE1 1 Storage, Equipment and Testing Room 80 80Open82SPD: Clean SRGC1 1 Storage, Ethylene Oxide Gas Cylinder 30 30 C-PUT PUT GWB-SC - GWB-SC 9'-0" 12 W 43SPD: Clean ORSS1 1 Storage, Sterile / Nonsterile 940 940 VCT RB GWB-SC - AT (SP) 9'-0" 12 UU-F 161SPD: Soiled JANC1 1 Housekeeping Aides Closet (HAC) 40 40 CT CT GWB-EPY CT 4'-0" AT (SP) 9'-0" 1 / 2 T 13SPD: Soiled TLTS1 1 Lockers, Toilet and Shower <strong>Facilities</strong> 80 80SPD: Soiled CWSH1 1 Manual Equipment Wash 80 80SPD: Soiled CSDE2 1 Receiving and Decontamination Area 300 3001 / 2 S-T /11 / 12 S-FVCT RB GWB--P - AT 9'-0" 1 / 2 S 1CT CT CT - PCP-SC 9'-0"WSF WSF GWB-SC - GWB-SC 9'-0"2 UU-T /12 UU-F2 UU-T /12 UU-F23 /4582 /16182 /161Finishes for Lockers and Lounge; See RoomCodes TLTU1 and SHWR1 for finishes required intoilets and showers if providedSurgerySurgery-Ambulatory Surgery OFD03 4 Administration: <strong>Office</strong>, Anesthesiologist/ Anesthetist 120 480 VCT / CP RB GWB-W - AT 9'-0" 1 / 2 S 23Surgery-Ambulatory Surgery OFA03 4 Administration: <strong>Office</strong>, Clerical 80 320 VCT / CP RB GWB-W - AT 9'-0" 1 / 2 S 23Surgery-Ambulatory Surgery OFD03 4 Administration: <strong>Office</strong>, Resident 120 480 VCT / CP RB GWB-W - AT 9'-0" 1 / 2 S 23Surgery-Ambulatory Surgery OFD03 4 Administration: <strong>Office</strong>, Staff Surgeon 120 480 VCT / CP RB GWB-W - AT 9'-0" 1 / 2 S 23Surgery-Ambulatory Surgery LR002 1 Changing Room, Patient 180 180 VCT RB GWB-P - AT 9'-0" 1 / 2 V 69WSF WSF GWB-SC - GWB-SC 9'-6"Surgery-Ambulatory Surgery ORCS1 1 Cystoscopic Room 450 450Surgery-Ambulatory Surgery XDCY1 1 Cystoscopy: External Radiographic Control Room 100 100 WSF WSF GWB-SC - GWB-SC 9'-6" Open -Surgery-Ambulatory Surgery JANC1 1 Cystoscopy: Housekeeping Aides Closet (HAC) 40 40 CT CT GWB-EPY CT 4'-0" AT (SP) 9'-0" 1 / 2 T 13Surgery-Ambulatory Surgery OREC1 1 Cystoscopy: Instrument Preparation and Storage Room 80 80 WSF WSF GWB-SC - GWB-SC 9'-0" 1 / 2 S-T 69Surgery-Ambulatory Surgery ORSA1 1 Cystoscopy: Scrub-up Area 30 30 WSF WSF GWB-SC - GWB-SC 9'-6" 3 / 4 S-T 68Surgery-Ambulatory Surgery RRSS1 1 Lounge, Postoperative Recovery 200 200WSF WSF GWB-SC - AT (SP) 9'-6"15 V-T /15 QQ-T1 / 2 SS-TADO104 /109126______Lessor Gov't_______ Room Finish, Door and Hardware--Schedule E Page 29 <strong>of</strong> 31 ___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXWainscotHardwareDepartment / Functional AreaRoomCode Qty FunctionSCHEDULE E: ROOM FINISH, DOOR, AND HARDWARE SCHEDULEUnitArea sf(eachroom)Net AreasfExcludefrom NetUsable Floor Base WallSurgery-Ambulatory Surgery NSTA1 1 Nurse Station 75 75 WSF WSF GWB-SC - AT (SP) 9'-6" Open -Surgery-Ambulatory Surgery ANCW1 1 OR: Anesthesia, Workroom and Equip. Storage 280 280 WSF WSF GWB-SC - GWB-SC 9'-6" 1 / 2 V-T 69Surgery-Ambulatory Surgery ORCW1 1 OR: Clean Core-Staff Workroom 640 640 WSF WSF GWB-SC - GWB-SC 9'-6" 1 / 2 VV-T 12Surgery-Ambulatory Surgery NSTA4 1 OR: Control and Communication Center 120 120 VCT RB GWB-P - AT 9'-0" 1 / 2 U 23Surgery-Ambulatory Surgery OFA03 1 OR: Cubicle, Dictation 15 15 CPT RB GWB--P - AT 9'-0" Open -Surgery-Ambulatory Surgery ORGS1 2 OR: General Operating Room (OR) 450 900WSF WSF GWB-SC - GWB-SC 9'-6"Surgery-Ambulatory Surgery ORPH2 3 OR: Holding Area, Patient 80 240 WSF WSF GWB-SC - GWB-SC 9'-6" Open -Surgery-Ambulatory Surgery JANC1 1 OR: Housekeeping Aides Closet 1 (HAC), Small 60 60 WSF WSF GWB-EPY CT 4'-0" AT (SP) 9'-0" 1 / 2 T 13Surgery-Ambulatory Surgery JANC1 1 OR: Housekeeping Aides Closet 2 (HAC), Large 100 100 WSF WSF GWB-EPY CT 4'-0" AT (SP) 9'-0" 1 / 2 T 13Surgery-Ambulatory Surgery XXYYC OR: Dedicated Electrical Room (if provided at Clean Core) WSF WSF GWB-EPY GWB-EPY 9'-6" 1 / 2 V 13Surgery-Ambulatory Surgery LBBP1 1 OR: Laboratory, Frozen Section 100 100 WSF WSF GWB-SC - GWB-SC 9'-6" 1 / 2 S 67Surgery-Ambulatory Surgery LR002 1 OR: Locker Room, Female Staff 192 192 VCT RB GWB--P - AT 9'-0" 1 / 2 S 1Surgery-Ambulatory Surgery LR002 1 OR: Locker Room, Male Staff 192 192 VCT RB GWB--P - AT 9'-0" 1 / 2 S 1Surgery-Ambulatory Surgery SL001 1 OR: Lounge, Nurses and other OR Staff 130 130 CP RB GWB--P - AT 9'-0" 1 / 2 S 1Surgery-Ambulatory Surgery SL001 1 OR: Lounge, Surgeons, Residents and Students 130 130 CP RB GWB--P - AT 9'-0" 1 / 2 S 1Surgery-Ambulatory Surgery OFD03 1 OR: <strong>Office</strong>, Head Nurse 120 120 VCT / CP RB GWB--P - AT 9'-0" 1 / 2 S 23WSF WSF GWB-SC - GWB-SC 9'-6" 1 / 2 S-T or15 S-V 108Surgery-Ambulatory Surgery ORSA1 1 OR: Scrub-up Area 110 110or OpenSurgery-Ambulatory Surgery USCL1 1 OR: Soiled Holding / Disposal Room 100 100 WSF WSF GWB-SC - GWB-SC 9'-6" 11 / 12 V-F 42Surgery-Ambulatory Surgery SRGC1 3 OR: Storage, Gas Cylinder Room 35 105 WSF WSF GWB-SC - GWB-SC 9'-6" 11 / 12 S 42Surgery-Ambulatory Surgery UCCL1 1 OR: Storage, Clean and Sterile Supplies 100 100 WSF WSF GWB-SC - GWB-SC 9'-6" 11 / 12 V-F 42Surgery-Ambulatory Surgery SRE01 2 OR: Storage, Equipment and Apparatus 100 200 WSF WSF GWB-SC - GWB-SC 9'-6" 11 / 12 V-F 42Surgery-Ambulatory Surgery SRLW1 3 OR: Storage, Gurney 24 72 WSF WSF GWB-SC - GWB-SC 9'-6" 1 / 2 V 4Surgery-Ambulatory Surgery ORSR1 1 OR: Substerile Room 100 100 WSF WSF GWB-SC - GWB-SC 9'-6" 15 S-V 121 / 2 S /CT CT GWB-P CT 4'-0" AT 9'-0"Surgery-Ambulatory Surgery TLTF2 1 OR: Toilet / Shower Room, Female Staff 125 125Open1 Full Height CT at Showers1 / 2 S /CT CT GWB-P CT 4'-0" AT 9'-0"Surgery-Ambulatory Surgery TLTM2 1 OR: Toilet / Shower Room, Male Staff 125 125Open1 Full Height CT at ShowersSurgery-Ambulatory Surgery MEDP1 1 Postanesthesia Recovery (PAR): Medication Preparation Room 55 55 WSF WSF GWB-SC - AT (SP) 9'-0" 1 / 2 U 13Surgery-Ambulatory Surgery NSTA4 1 Postanesthesia Recovery (PAR): Nurse Station 120 120 WSF WSF GWB-SC - AT (SP) 9'-0" Open -Surgery-Ambulatory Surgery RROP1 6 Postanesthesia Recovery (PAR): Recovery Bed 140 840 WSF WSF GWB-SC - AT (SP) 9'-0" Open -Surgery-Ambulatory Surgery SRS01 1 Postanesthesia Recovery (PAR): Storage 70 70 WSF WSF GWB-SC - GWB-SC 9'-0" 1 /2 V 42Surgery-Ambulatory Surgery TLTU1 1 Postanesthesia Recovery (PAR): Toilet, Staff 50 50 CT CT GWB-P CT 4'-0" AT 9'-0" 1 / 2 S 18Surgery-Ambulatory Surgery UCCL1 1 Postanesthesia Recovery (PAR): Utility Room, Clean 100 100 WSF WSF GWB-SC - GWB-SC 9'-0" 11 / 12 V-F 42Surgery-Ambulatory Surgery USCL1 1 Postanesthesia Recovery (PAR): Utility Room, Soiled 80 80 WSF WSF GWB-SC - GWB-SC 9'-0" 11 / 12 V-F 42Surgery-Ambulatory Surgery RECP1 1 Reception 120 120 Open -Surgery-Ambulatory Surgery RCA01 1 Storage, Crash Cart 20 20 WSF WSF GWB-SC - GWB-SC 9'-0" Open -Surgery-Ambulatory Surgery TLTU1 2 Toilet, Patient 50 100 CT CT GWB-P CT 4'-0" AT 9'-0" 1 / 2 S 181 / 2 S-TCP RB GWB-W - AT 9'-0"Surgery-Ambulatory Surgery WRF01 1 Waiting, Patient / Family 140 140/ Open40Surgery-Minor Surgery DR001 1 Changing Room, Patient 180 180 VCT RB GWB-P - GWB-P 9'-0" 1 / 2 S 1Surgery-Minor Surgery NSTA1 1 Control and Communication Center 90 90 WSF WSF GWB-SC - GWB-SC 9'-6" Open -Surgery-Minor Surgery ORPH2 1 Holding Area, Patient 80 80 WSF WSF GWB-SC - GWB-SC 9'-6" Open -Surgery-Minor Surgery JANC1 1 Housekeeping Aides Closet 60 60 CT CT GWB-EPY CT 4'-0" AT (SP) 9'-0" 1 / 2 T 13Surgery-Minor Surgery LR002 1 Locker Room, Female Staff 48 48 VCT RB GWB--P - AT 9'-0" 1 / 2 S 1Surgery-Minor Surgery LR002 1 Locker Room, Male Staff 48 48 VCT RB GWB--P - AT 9'-0" 1 / 2 S 1Surgery-Minor Surgery RRSS1 1 Lounge, Postoperative Recovery 200 200 WSF WSF GWB-SC - AT (SP) 9'-0" 1 / 2 X-T 67Surgery-Minor Surgery TRGS1 2 Minor Procedure / Operating Room (OR) 250 500WSF WSF GWB-SC - GWB-SC 9'-6"Surgery-Minor Surgery NSTA1 1 Nurse Station 75 75 WSF WSF GWB-SC - AT (SP) 9'-6" Open -Surgery-Minor Surgery OFA02 1 <strong>Office</strong>, Head Nurse 120 120 VCT / CP RB GWB--P - AT 9'-0" 1 / 2 S 231 / 2 S-TVCT / CP RB GWB-W - AT 9'-0"Surgery-Minor Surgery RECP1 1 Reception 120 120/ Open40WSF WSF GWB-SC - GWB-SC 9'-6" 1 / 2 S-T or15 S-V 108Surgery-Minor Surgery ORSA1 1 Scrub Room / Sterilizer Area 100 100or OpenSurgery-Minor Surgery USCL1 1 Soiled Holding / Disposal Room 80 80 WSF WSF GWB-SC - GWB-SC 9'-6" 11 / 12 V-F 42Surgery-Minor Surgery SRGC1 1 Storage, Gas Cylinder Room 35 35 WSF WSF GWB-SC - GWB-SC 9'-6" 11 / 12 V-F 42Surgery-Minor Surgery UCCL1 1 Storage, Clean And Sterile Supplies 80 80 WSF WSF GWB-SC - GWB-SC 9'-6" 11 / 12 V-F 42Surgery-Minor Surgery RCA01 1 Storage, Crash Cart 20 20 WSF WSF GWB-SC - GWB-SC 9'-6" Open -Surgery-Minor Surgery SRE01 1 Storage, Equipment and Apparatus 80 80 WSF WSF GWB-SC - GWB-SC 9'-6" 11 / 12 V-F 42Surgery-Minor Surgery SRLW1 1 Storage, Gurney 24 24 WSF WSF GWB-SC - GWB-SC 9'-6" 1 / 2 V 4Surgery-Minor Surgery TLTU1 2 Toilet, Patient 50 100 CT CT GWB-P CT 4'-0" AT 9'-0" 1 / 2 S 18CeilingCeilingHeightDoorSymbol1 / 2 X-T /1 / 2 QQ-T1 / 2 X-T /1 / 2 QQ-T12 /7912 /79Notes______Lessor Gov't_______ Room Finish, Door and Hardware--Schedule E Page 30 <strong>of</strong> 31 ___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXWainscotHardwareRoomCode Qty FunctionSCHEDULE E: ROOM FINISH, DOOR, AND HARDWARE SCHEDULEUnitArea sf(eachroom)Net AreasfExcludefrom NetUsable Floor Base WallDepartment / Functional AreaCeilingSurgery-Minor Surgery TLTU1 2 Toilet, Staff 50 100 CT CT GWB-P CT 4'-0" AT 9'-0" 1 / 2 S 18Surgery-Minor Surgery WRF01 1 Waiting, Patient and Family 120 120CP RB GWB-W - AT 9'-0"XXYYC Corridors, Semi-Restricted (Peripheral) WSF WSF GWB-SC -CeilingHeightDoorSymbol1 / 2 S-T/ Open40NotesVoluntary ServiceVoluntary Service OFA01 1 <strong>Office</strong>, Chief 150 150 VCT / CP RB GWB-W - AT 9'-0" 1 / 2 S 231 / 2 S-TVCT / CP RB GWB-W - AT 9'-0"Voluntary Service OFA03 1 <strong>Office</strong>, Clerical Support 80 80/ Open231 / 2 S-TVCT / CP RB GWB-W - AT 9'-0"Voluntary Service SEC01 1 <strong>Office</strong>, Secretary 120 120/ Open23Voluntary Service OFA03 3 Organization Workstation 120 360 VCT / CP RB GWB-W - AT 9'-0" 1 / 2 V-T 23Voluntary Service SRS01 1 Storage 80 80 VCT RB GWB-P - AT 9'-0" 1 / 2 S 13Voluntary Service WRCH1 1 Volunteer Multipurpose Room 150 150 VCT / CP RB GWB-W - AT 9'-0" 1 / 2 V-T 23Voluntary Service OFA03 1 Volunteer Sign-in Area 60 60 VCT / CP RB GWB-W - AT 9'-0" Open -General and Common Spaces-- CorridorVCT RB GWB-W - AT 8'-0" 1 / 2 QQ-T6 /120C-EPY RB GWB-P - EXP -1 / 2 VVor11 / 12 VV-F-- Equipment Room (mechanical)-- Equipment Room (electrical, communications) C-EPY RB GWB-P - EXP - 1 / 2 V 1313 /43______Lessor Gov't_______ Room Finish, Door and Hardware--Schedule E Page 31 <strong>of</strong> 31 ___ <strong>of</strong> _____ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> No. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]PART VIILABOR STANDARDS PROVISIONPart VII: Labor Standards Provisions--Page 1 <strong>of</strong> 13Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> No. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]PART VII: LABOR STANDARDS PROVISIONS1. CONTRACT WORK HOURS AND SAFETY STANDARDS ACT-OVERTIME COMPENSATION (FAR52.222-4) (JULY 2005)(a) Overtime requirements. No Contractor or subcontractor employing laborers or mechanics (seeFederal Acquisition Regulation 22.300) shall require or permit them to work over 40 hours in anyworkweek unless they are paid at least 1 and 1/2 times the basic rate <strong>of</strong> pay for each hour worked over40 hours.(b) Violation; liability for unpaid wages; liquidated damages. The responsible Contractor andsubcontractor are liable for unpaid wages if they violate the terms in paragraph (a) <strong>of</strong> this clause. Inaddition, the Contractor and subcontractor are liable for liquidated damages payable to the Government.The Contracting <strong>Office</strong>r will assess liquidated damages at the rate <strong>of</strong> $10 per affected employee for eachcalendar day on which the employer required or permitted the employee to work in excess <strong>of</strong> the standardworkweek <strong>of</strong> 40 hours without paying overtime wages required by the Contract Work Hours and SafetyStandards Act.(c) Withholding for unpaid wages and liquidated damages. The Contracting <strong>Office</strong>r will withhold frompayments due under the contract sufficient funds required to satisfy any Contractor or subcontractorliabilities for unpaid wages and liquidated damages. If amounts withheld under the contract are insufficientto satisfy Contractor or subcontractor liabilities, the Contracting <strong>Office</strong>r will withhold payments from otherFederal or federally assisted contracts held by the same Contractor that are subject to the Contract WorkHours and Safety Standards Act.(d) Payrolls and basic records.(1) The Contractor and its subcontractors shall maintain payrolls and basic payroll records for alllaborers and mechanics working on the contract during the contract and shall make them available to theGovernment until 3 years after contract completion. The records shall contain the name and address <strong>of</strong>each employee, social security number, labor classifications, hourly rates <strong>of</strong> wages paid, daily and weeklynumber <strong>of</strong> hours worked, deductions made, and actual wages paid. The records need not duplicate thoserequired for construction work by Department <strong>of</strong> Labor regulations at 29 CFR 5.5(a)(3) implementing theDavis-Bacon Act.(2) The Contractor and its subcontractors shall allow authorized representatives <strong>of</strong> the Contracting<strong>Office</strong>r or the Department <strong>of</strong> Labor to inspect, copy, or transcribe records maintained underparagraph (d)(1) <strong>of</strong> this clause. The Contractor or subcontractor also shall allow authorized representativesPart VII: Labor Standards Provisions--Page 2 <strong>of</strong> 13Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> No. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]<strong>of</strong> the Contracting <strong>Office</strong>r or Department <strong>of</strong> Labor to interview employees in the workplace during workinghours.(e) Subcontracts. The Contractor shall insert the provisions set forth in paragraphs (a) through (d) <strong>of</strong> thisclause in subcontracts that may require or involve the employment <strong>of</strong> laborers and mechanics and requiresubcontractors to include these provisions in any such lower tier subcontracts. The Contractor shall beresponsible for compliance by any subcontractor or lower-tier subcontractor with the provisions set forth inparagraphs (a) through (d) <strong>of</strong> this clause.2. DAVIS-BACON ACT FAR 52.222-6 (JULY 2005)(a) Definition.—“Site <strong>of</strong> the work”—(1) Means—(i) The primary site <strong>of</strong> the work. The physical place or places where the construction called for inthe contract will remain when work on it is completed; and(ii) The secondary site <strong>of</strong> the work, if any. Any other site where a significant portion <strong>of</strong> the buildingor work is constructed, provided that such site is—(A) Located in the United States; and(B) Established specifically for the performance <strong>of</strong> the contract or project;(2) Except as provided in paragraph (3) <strong>of</strong> this definition, includes any fabrication plants, mobilefactories, batch plants, borrow pits, job headquarters, tool yards, etc., provided—(i) They are dedicated exclusively, or nearly so, to performance <strong>of</strong> the contract or project; and(ii) They are adjacent or virtually adjacent to the “primary site <strong>of</strong> the work” as defined in paragraph(a)(1)(i), or the “secondary site <strong>of</strong> the work” as defined in paragraph (a)(1)(ii) <strong>of</strong> this definition;(3) Does not include permanent home <strong>of</strong>fices, branch plant establishments, fabrication plants, or toolyards <strong>of</strong> a Contractor or subcontractor whose locations and continuance in operation are determinedwholly without regard to a particular Federal contract or project. In addition, fabrication plants, batch plants,borrow pits, job headquarters, yards, etc., <strong>of</strong> a commercial or material supplier which are established by asupplier <strong>of</strong> materials for the project before opening <strong>of</strong> bids and not on the Project site, are not included inthe “site <strong>of</strong> the work.” Such permanent, previously established facilities are not a part <strong>of</strong> the “site <strong>of</strong> thework” even if the operations for a period <strong>of</strong> time may be dedicated exclusively or nearly so, to theperformance <strong>of</strong> a contract.(b)(1) All laborers and mechanics employed or working upon the site <strong>of</strong> the work will be paidunconditionally and not less <strong>of</strong>ten than once a week, and without subsequent deduction or rebate on anyaccount (except such payroll deductions as are permitted by regulations issued by the Secretary <strong>of</strong> Laborunder the Copeland Act (29 CFR part 3)), the full amount <strong>of</strong> wages and bona fide fringe benefits (or cashequivalents there<strong>of</strong>) due at time <strong>of</strong> payment computed at rates not less than those contained in the wagePart VII: Labor Standards Provisions--Page 3 <strong>of</strong> 13Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> No. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]determination <strong>of</strong> the Secretary <strong>of</strong> Labor which is attached hereto and made a part here<strong>of</strong>, or as may beincorporated for a secondary site <strong>of</strong> the work, regardless <strong>of</strong> any contractual relationship which may bealleged to exist between the Contractor and such laborers and mechanics. Any wage determinationincorporated for a secondary site <strong>of</strong> the work shall be effective from the first day on which work under thecontract was performed at that site and shall be incorporated without any adjustment in contract price orestimated cost. Laborers employed by the construction Contractor or construction subcontractor that aretransporting portions <strong>of</strong> the building or work between the secondary site <strong>of</strong> the work and the primary site <strong>of</strong>the work shall be paid in accordance with the wage determination applicable to the primary site <strong>of</strong> thework.(2) Contributions made or costs reasonably anticipated for bona fide fringe benefits under section1(b)(2) <strong>of</strong> the Davis-Bacon Act on behalf <strong>of</strong> laborers or mechanics are considered wages paid to suchlaborers or mechanics, subject to the provisions <strong>of</strong> paragraph (e) <strong>of</strong> this clause; also, regular contributionsmade or costs incurred for more than a weekly period (but not less <strong>of</strong>ten than quarterly) under plans,funds, or programs which cover the particular weekly period, are deemed to be constructively made orincurred during such period.(3) Such laborers and mechanics shall be paid not less than the appropriate wage rate and fringebenefits in the wage determination for the classification <strong>of</strong> work actually performed, without regard to skill,except as provided in the clause entitled Apprentices and Trainees. Laborers or mechanics performingwork in more than one classification may be compensated at the rate specified for each classification forthe time actually worked therein; provided that the employer’s payroll records accurately set forth the timespent in each classification in which work is performed.(4) The wage determination (including any additional classifications and wage rates conformed underparagraph (c) <strong>of</strong> this clause) and the Davis-Bacon poster (WH-1321) shall be posted at all times by theContractor and its subcontractors at the primary site <strong>of</strong> the work and the secondary site <strong>of</strong> the work, if any,in a prominent and accessible place where it can be easily seen by the workers.(c)(1) The Contracting <strong>Office</strong>r shall require that any class <strong>of</strong> laborers or mechanics which is not listed inthe wage determination and which is to be employed under the contract shall be classified in conformancewith the wage determination. The Contracting <strong>Office</strong>r shall approve an additional classification and wagerate and fringe benefits therefor only when all the following criteria have been met:(i) The work to be performed by the classification requested is not performed by a classification inthe wage determination.(ii) The classification is utilized in the area by the construction industry.(iii) The proposed wage rate, including any bona fide fringe benefits, bears a reasonablerelationship to the wage rates contained in the wage determination.(2) If the Contractor and the laborers and mechanics to be employed in the classification (if known),or their representatives, and the Contracting <strong>Office</strong>r agree on the classification and wage rate (includingPart VII: Labor Standards Provisions--Page 4 <strong>of</strong> 13Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> No. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]the amount designated for fringe benefits, where appropriate), a report <strong>of</strong> the action taken shall be sent bythe Contracting <strong>Office</strong>r to the Administrator <strong>of</strong> the:Wage and Hour DivisionEmployment Standards AdministrationU.S. Department <strong>of</strong> LaborWashington, DC 20210The Administrator or an authorized representative will approve, modify, or disapprove every additionalclassification action within 30 days <strong>of</strong> receipt and so advise the Contracting <strong>Office</strong>r or will notify theContracting <strong>Office</strong>r within the 30-day period that additional time is necessary.(3) In the event the Contractor, the laborers or mechanics to be employed in the classification, ortheir representatives, and the Contracting <strong>Office</strong>r do not agree on the proposed classification and wagerate (including the amount designated for fringe benefits, where appropriate), the Contracting <strong>Office</strong>r shallrefer the questions, including the views <strong>of</strong> all interested parties and the recommendation <strong>of</strong> the Contracting<strong>Office</strong>r, to the Administrator <strong>of</strong> the Wage and Hour Division for determination. The Administrator, or anauthorized representative, will issue a determination within 30 days <strong>of</strong> receipt and so advise theContracting <strong>Office</strong>r or will notify the Contracting <strong>Office</strong>r within the 30-day period that additional time isnecessary.(4) The wage rate (including fringe benefits, where appropriate) determined pursuant toparagraphs (c)(2) and (c)(3) <strong>of</strong> this clause shall be paid to all workers performing work in the classificationunder this contract from the first day on which work is performed in the classification.(d) Whenever the minimum wage rate prescribed in the contract for a class <strong>of</strong> laborers or mechanicsincludes a fringe benefit which is not expressed as an hourly rate, the Contractor shall either pay thebenefit as stated in the wage determination or shall pay another bona fide fringe benefit or an hourly cashequivalent there<strong>of</strong>.(e) If the Contractor does not make payments to a trustee or other third person, the Contractor mayconsider as part <strong>of</strong> the wages <strong>of</strong> any laborer or mechanic the amount <strong>of</strong> any costs reasonably anticipatedin providing bona fide fringe benefits under a plan or program; provided, That the Secretary <strong>of</strong> Labor hasfound, upon the written request <strong>of</strong> the Contractor, that the applicable standards <strong>of</strong> the Davis-Bacon Acthave been met. The Secretary <strong>of</strong> Labor may require the Contractor to set aside in a separate accountassets for the meeting <strong>of</strong> obligations under the plan or program.3. WITHHOLDING OF FUNDS (FAR 52.222-7) (FEB 1988)The Contracting <strong>Office</strong>r shall, upon his or her own action or upon written request <strong>of</strong> an authorizedrepresentative <strong>of</strong> the Department <strong>of</strong> Labor, withhold or cause to be withheld from the Contractor under thiscontract or any other Federal contract with the same Prime Contractor, or any other Federally assistedcontract subject to Davis-Bacon prevailing wage requirements, which is held by the same PrimePart VII: Labor Standards Provisions--Page 5 <strong>of</strong> 13Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> No. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Contractor, so much <strong>of</strong> the accrued payments or advances as may be considered necessary to paylaborers and mechanics, including apprentices, trainees, and helpers, employed by the Contractor or anysubcontractor the full amount <strong>of</strong> wages required by the contract. In the event <strong>of</strong> failure to pay any laboreror mechanic, including any apprentice, trainee, or helper, employed or working on the site <strong>of</strong> the work, allor part <strong>of</strong> the wages required by the contract, the Contracting <strong>Office</strong>r may, after written notice to theContractor, take such action as may be necessary to cause the suspension <strong>of</strong> any further payment,advance, or guarantee <strong>of</strong> funds until such violations have ceased.4. PAYROLLS AND BASIC RECORDS (FAR 52.222-8) (FEB 1988)(a) Payrolls and basic records relating thereto shall be maintained by the Contractor during thecourse <strong>of</strong> the work and preserved for a period <strong>of</strong> 3 years thereafter for all laborers and mechanics workingat the site <strong>of</strong> the work. Such records shall contain the name, address, and social security number <strong>of</strong> eachsuch worker, his or her correct classification, hourly rates <strong>of</strong> wages paid (including rates <strong>of</strong> contributions orcosts anticipated for bona fide fringe benefits or cash equivalents there<strong>of</strong> <strong>of</strong> the types described in section1 (b)(2)(B) <strong>of</strong> the Davis-Bacon Act), daily and weekly number <strong>of</strong> hours worked, deductions made, andactual wages paid. Whenever the Secretary <strong>of</strong> Labor has found, under paragraph (d) <strong>of</strong> the clause entitledDavis-Bacon Act, that the wages <strong>of</strong> any laborer or mechanic include the amount <strong>of</strong> any costs reasonablyanticipated in providing benefits under a plan or program described in section 1 (b)(2)(B) <strong>of</strong> the Davis-Bacon Act, the Contractor shall maintain records which show that the commitment to provide such benefitsis enforceable, that the plan or program is financially responsible, and that the plan or program has beencommunicated in writing to the laborers or mechanics affected, and records which show the costsanticipated or the actual cost incurred in providing such benefits. Contractors employing apprentices ortrainees under approved programs shall maintain written evidence <strong>of</strong> the registration <strong>of</strong> apprenticeshipprograms and certification <strong>of</strong> trainee programs, the registration <strong>of</strong> the apprentices and trainees, and theratios and wage rates prescribed in the applicable programs.(b)(1) The Contractor shall submit weekly for each week in which any contract work is performed acopy <strong>of</strong> all payrolls to the Contracting <strong>Office</strong>r. The payrolls submitted shall set out accurately andcompletely all <strong>of</strong> the information required to be maintained under paragraph (a) <strong>of</strong> this clause. Thisinformation may be submitted in any form desired. Optional Form WH-347 (Federal Stock Number 029-005-00014-1) is available for this purpose and may be purchased from the Superintendent <strong>of</strong> Documents,U.S. Government Printing <strong>Office</strong>, Washington, DC 20402. The Prime Contractor is responsible for thesubmission <strong>of</strong> copies <strong>of</strong> payrolls by all subcontractors.(2) Each payroll submitted shall be accompanied by a "Statement <strong>of</strong> Compliance," signed by theContractor or subcontractor or his or her agent who pays or supervises the payment <strong>of</strong> the personsemployed under the contract and shall certifyPart VII: Labor Standards Provisions--Page 6 <strong>of</strong> 13Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> No. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY](i) That the payroll for the payroll period contains the information required to be maintained underparagraph (a) <strong>of</strong> this clause and that such information is correct and complete;(ii) That each laborer or mechanic (including each helper, apprentice, and trainee) employed onthe contract during the payroll period has been paid the full weekly wages earned, without rebate, eitherdirectly or indirectly, and that no deductions have been made either directly or indirectly from the fullwages earned, other than permissible deductions as set forth in the Regulations, 29 CFR Part 3; and(iii) That each laborer or mechanic has been paid not less than the applicable wage rates andfringe benefits or cash equivalents for the classification <strong>of</strong> work performed, as specified in the applicablewage determination incorporated into the contract.(3) The weekly submission <strong>of</strong> a properly executed certification set forth on the reverse side <strong>of</strong>Optional Form WH-347 shall satisfy the requirement for submission <strong>of</strong> the "Statement <strong>of</strong> Compliance"required by subparagraph (b)(2) <strong>of</strong> this clause.(4) The falsification <strong>of</strong> any <strong>of</strong> the certifications in this clause may subject the Contractor orsubcontractor to civil or criminal prosecution under Section 1001 <strong>of</strong> Title 18, and Section 3729 <strong>of</strong> Title 31 <strong>of</strong>the United States Code.(c) The Contractor or subcontractor shall make the records required under paragraph (a) <strong>of</strong> thisclause available for inspection, copying, or transcription by the Contracting <strong>Office</strong>r or authorizedrepresentatives <strong>of</strong> the Contracting <strong>Office</strong>r or the Department <strong>of</strong> Labor. The Contractor or subcontractorshall permit the Contracting <strong>Office</strong>r or representatives <strong>of</strong> the Contracting <strong>Office</strong>r or the Department <strong>of</strong>Labor to interview employees during working hours on the job. If the Contractor or subcontractor fails tosubmit required records or to make them available, the Contracting <strong>Office</strong>r may, after written notice to theContractor, take such action as may be necessary to cause the suspension <strong>of</strong> any further payment.Furthermore, failure to submit the required records upon request or to make such records available maybe grounds for debarment action pursuant to 29 CFR 5.12.5. APPRENTICES AND TRAINEES (FAR 52.222-9)(JULY 2005)(a) Apprentices.(1) An apprentice will be permitted to work at less than the predetermined rate for the work performedwhen employed—(i) Pursuant to and individually registered in a bona fide apprenticeship program registered withthe U.S. Department <strong>of</strong> Labor, Employment and Training Administration, <strong>Office</strong> <strong>of</strong> Apprenticeship Training,Employer, and Labor Services (OATELS) or with a State Apprenticeship Agency recognized by theOATELS; orPart VII: Labor Standards Provisions--Page 7 <strong>of</strong> 13Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> No. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY](ii) In the first 90 days <strong>of</strong> probationary employment as an apprentice in such an apprenticeshipprogram, even though not individually registered in the program, if certified by the OATELS or a StateApprenticeship Agency (where appropriate) to be eligible for probationary employment as an apprentice.(2) The allowable ratio <strong>of</strong> apprentices to journeymen on the job site in any craft classification shall notbe greater than the ratio permitted to the Contractor as to the entire work force under the registeredprogram.(3) Any worker listed on a payroll at an apprentice wage rate, who is not registered or otherwiseemployed as stated in paragraph (a)(1) <strong>of</strong> this clause, shall be paid not less than the applicable wagedetermination for the classification <strong>of</strong> work actually performed. In addition, any apprentice performing workon the job site in excess <strong>of</strong> the ratio permitted under the registered program shall be paid not less than theapplicable wage rate on the wage determination for the work actually performed.(4) Where a Contractor is performing construction on a project in a locality other than that in which itsprogram is registered, the ratios and wage rates (expressed in percentages <strong>of</strong> the journeyman’s hourlyrate) specified in the Contractor’s or subcontractor’s registered program shall be observed. Everyapprentice must be paid at not less than the rate specified in the registered program for the apprentice’slevel <strong>of</strong> progress, expressed as a percentage <strong>of</strong> the journeyman hourly rate specified in the applicablewage determination.(5) Apprentices shall be paid fringe benefits in accordance with the provisions <strong>of</strong> the apprenticeshipprogram. If the apprenticeship program does not specify fringe benefits, apprentices must be paid the fullamount <strong>of</strong> fringe benefits listed on the wage determination for the applicable classification. If theAdministrator determines that a different practice prevails for the applicable apprentice classification,fringes shall be paid in accordance with that determination.(6) In the event OATELS, or a State Apprenticeship Agency recognized by OATELS, withdrawsapproval <strong>of</strong> an apprenticeship program, the Contractor will no longer be permitted to utilize apprentices atless than the applicable predetermined rate for the work performed until an acceptable program isapproved.(b) Trainees.(1) Except as provided in 29 CFR 5.16, trainees will not be permitted to work at less than thepredetermined rate for the work performed unless they are employed pursuant to and individuallyregistered in a program which has received prior approval, evidenced by formal certification by the U.S.Department <strong>of</strong> Labor, Employment and Training Administration, <strong>Office</strong> <strong>of</strong> Apprenticeship Training,Employer, and Labor Services (OATELS). The ratio <strong>of</strong> trainees to journeymen on the job site shall not begreater than permitted under the plan approved by OATELS.(2) Every trainee must be paid at not less than the rate specified in the approved program for thetrainee’s level <strong>of</strong> progress, expressed as a percentage <strong>of</strong> the journeyman hourly rate specified in theapplicable wage determination. Trainees shall be paid fringe benefits in accordance with the provisions <strong>of</strong>Part VII: Labor Standards Provisions--Page 8 <strong>of</strong> 13Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> No. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]the trainee program. If the trainee program does not mention fringe benefits, trainees shall be paid the fullamount <strong>of</strong> fringe benefits listed in the wage determination unless the Administrator <strong>of</strong> the Wage and HourDivision determines that there is an apprenticeship program associated with the correspondingjourneyman wage rate in the wage determination which provides for less than full fringe benefits forapprentices. Any employee listed on the payroll at a trainee rate who is not registered and participating ina training plan approved by the OATELS shall be paid not less than the applicable wage rate in the wagedetermination for the classification <strong>of</strong> work actually performed. In addition, any trainee performing work onthe job site in excess <strong>of</strong> the ratio permitted under the registered program shall be paid not less than theapplicable wage rate in the wage determination for the work actually performed.(3) In the event OATELS withdraws approval <strong>of</strong> a training program, the Contractor will no longer bepermitted to utilize trainees at less than the applicable predetermined rate for the work performed until anacceptable program is approved.(c) Equal employment opportunity. The utilization <strong>of</strong> apprentices, trainees, and journeymen under thisclause shall be in conformity with the equal employment opportunity requirements <strong>of</strong> ExecutiveOrder 11246, as amended, and 29 CFR Part 30.6. COMPLIANCE WITH COPELAND ACT REQUIREMENTS (FAR 52.222-10) (FEB 1988)The Contractor shall comply with the requirements <strong>of</strong> 29 CFR Part 3, which are herebyincorporated by reference in this contract.7. SUBCONTRACTS (LABOR STANDARDS) (FAR 52.222-11) (JULY 2005)(a) Definition. “<strong>Construction</strong>, alteration or repair,” as used in this clause, means all types <strong>of</strong> work doneby laborers and mechanics employed by the construction Contractor or construction subcontractor on aparticular building or work at the site there<strong>of</strong>, including without limitation—(1) Altering, remodeling, installation (if appropriate) on the site <strong>of</strong> the work <strong>of</strong> items fabricated <strong>of</strong>f-site;(2) Painting and decorating;(3) Manufacturing or furnishing <strong>of</strong> materials, articles, supplies, or equipment on the site <strong>of</strong> the buildingor work;(4) Transportation <strong>of</strong> materials and supplies between the site <strong>of</strong> the work within the meaning <strong>of</strong>paragraphs (a)(1)(i) and (ii) <strong>of</strong> the “site <strong>of</strong> the work” as defined in the FAR clause at 52.222-6, Davis-BaconAct <strong>of</strong> this contract, and a facility which is dedicated to the construction <strong>of</strong> the building or work and isdeemed part <strong>of</strong> the site <strong>of</strong> the work within the meaning <strong>of</strong> paragraph (2) <strong>of</strong> the “site <strong>of</strong> work” definition; and(5) Transportation <strong>of</strong> portions <strong>of</strong> the building or work between a secondary site where a significantportion <strong>of</strong> the building or work is constructed, which is part <strong>of</strong> the “site <strong>of</strong> the work” definition in paragraphPart VII: Labor Standards Provisions--Page 9 <strong>of</strong> 13Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> No. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY](a)(1)(ii) <strong>of</strong> the FAR clause at 52.222-6, Davis-Bacon Act, and the physical place or places where thebuilding or work will remain (paragraph (a)(1)(i) <strong>of</strong> the FAR clause at 52.222-6, in the “site <strong>of</strong> the work”definition).(b) The Contractor shall insert in any subcontracts for construction, alterations and repairs within theUnited States the clauses entitled—(1) Davis-Bacon Act;(2) Contract Work Hours and Safety Standards Act—Overtime Compensation (if the clause isincluded in this contract);(3) Apprentices and Trainees;(4) Payrolls and Basic Records;(5) Compliance with Copeland Act Requirements;(6) Withholding <strong>of</strong> Funds;(7) Subcontracts (Labor Standards);(8) Contract Termination—Debarment;(9) Disputes Concerning Labor Standards;(10) Compliance with Davis-Bacon and Related Act Regulations; and(11) Certification <strong>of</strong> Eligibility.(c) The prime Contractor shall be responsible for compliance by any subcontractor or lower tiersubcontractor performing construction within the United States with all the contract clauses cited inparagraph (b).(d)(1) Within 14 days after award <strong>of</strong> the contract, the Contractor shall deliver to the Contracting <strong>Office</strong>r acompleted Standard Form (SF) 1413, Statement and Acknowledgment, for each subcontract forconstruction within the United States, including the subcontractor’s signed and dated acknowledgment thatthe clauses set forth in paragraph (b) <strong>of</strong> this clause have been included in the subcontract.(2) Within 14 days after the award <strong>of</strong> any subsequently awarded subcontract the Contractor shalldeliver to the Contracting <strong>Office</strong>r an updated completed SF 1413 for such additional subcontract.(e) The Contractor shall insert the substance <strong>of</strong> this clause, including this paragraph (e) in allsubcontracts for construction within the United States.8. CONTRACT TERMINATION--DEBARMENT (FAR 52.222-12) (FEB 1988)A breach <strong>of</strong> the contract clauses entitled Davis-Bacon Act, Contract Work Hours and SafetyStandards Act-Overtime Compensation, Apprentices and Trainees, Payrolls and Basic Records,Compliance with Copeland Act Requirements, Subcontracts (Labor Standards), Compliance with Davis-Bacon and Related Act Regulations, or Certification <strong>of</strong> Eligibility may be grounds for termination <strong>of</strong> thecontract, and for debarment as a Contractor and subcontractor as provided in 29 CFR 5.12.Part VII: Labor Standards Provisions--Page 10 <strong>of</strong> 13Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> No. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]9. COMPLIANCE WITH DAVIS-BACON AND RELATED ACT REGULATIONS (FAR 52.222-13) (FEB1988)All rulings and interpretations <strong>of</strong> the Davis-Bacon and Related Acts contained in 29 CFR Parts 1,3, and 5 are hereby incorporated by reference in this contract.10. DISPUTES CONCERNING LABOR STANDARDS (FAR 522.222-14) (FEB 1988)The United States Department <strong>of</strong> Labor has set forth in 29 CFR Parts 5, 6, and 7 procedures forresolving disputes concerning labor standards requirements. Such disputes shall be resolved inaccordance with those procedures and not the Disputes clause <strong>of</strong> this contract. Disputes within themeaning <strong>of</strong> this clause include disputes between the Contractor (or any <strong>of</strong> its subcontractors) and thecontracting agency, the U.S. Department <strong>of</strong> Labor, or the employees or their representatives.11. CERTIFICATION OF ELIGIBILITY (FAR 52.222-15) (FEB 1988)(a) By entering into this contract, the Contractor certifies that neither it (nor he or she) nor anyperson or firm who has an interest in the Contractor's firm is a person or firm ineligible to be awardedGovernment contracts by virtue <strong>of</strong> section 3(a) <strong>of</strong> the Davis-Bacon Act or 29 CFR 5.12(a)(1).(b) No part <strong>of</strong> this contract shall be subcontracted to any person or firm ineligible for award <strong>of</strong> aGovernment contract by virtue <strong>of</strong> section 3(a) <strong>of</strong> the Davis-Bacon Act or 29 CFR 5.12(a)(1).(c) The penalty for making false statements is prescribed in the U.S. Criminal Code, 18 U.S.C.1001.12. SUPPLEMENTARY LABOR STANDARDS PROVISIONS (VAAR 852.236-85) (APR 1984)(a) The wage determination decision <strong>of</strong> the Secretary <strong>of</strong> Labor is set forth in section G. R. GeneralRequirements, <strong>of</strong> this contract. It is the result <strong>of</strong> a study <strong>of</strong> wage conditions in the locality and establishesthe minimum hourly rates <strong>of</strong> wages and fringe benefits for the described classes <strong>of</strong> labor in accordancewith applicable law. No increase in the contract price will be allowed or authorized because <strong>of</strong> payment <strong>of</strong>wage rates in excess <strong>of</strong> those listed.(b) The contractor shall submit the required copies <strong>of</strong> payrolls to the contracting <strong>of</strong>ficer through theresident engineer or engineer <strong>of</strong>ficer, when acting in that capacity. Department <strong>of</strong> Labor Form WH-347,Payroll, available from the Superintendent <strong>of</strong> Documents, Government Printing <strong>Office</strong>, Washington, D.C.20402, may be used for this purpose. If, however, the contractor or subcontractor elects to use anindividually composed payroll form, it shall contain the same information shown on Form WH-347, and inPart VII: Labor Standards Provisions--Page 11 <strong>of</strong> 13Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> No. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]addition to be accompanied by Department <strong>of</strong> Labor Form WH-348, Statement <strong>of</strong> Compliance, or anyother form containing the exact wording <strong>of</strong> this form.Part VII: Labor Standards Provisions--Page 12 <strong>of</strong> 13Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> No. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY][INSERT CURRENT WAGE RATES HERE]Part VII: Labor Standards Provisions--Page 13 <strong>of</strong> 13Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]THIS PAGE INTENTIONALLY LEFT BLANK FOR REPRODUCTION PURPOSES.Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]PART VIIIFORMSPart VIII -- FormsLessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]PART VIII FORMSPROPOSAL TO LEASE SPACE (FORM 1364A)LESSOR’S ANNUAL COST STATEMENT (FORM 1217)SOLICITATION PROVISIONS (FORM 3516A)GENERAL CLAUSES (FORM 3517B)REPRESENTATIONS AND CERTIFICATIONS (FORM 3518)U.S. GOVERNMENT LEASE FORM (SF 2)ARCHITECT-ENGINEER QUALIFICATIONS (SF 330)CONTRACTOR’S QUALIFICATIONS AND FINANCIAL INFORMATION (FORM 527)PAST PERFORMANCE SURVEY FORMBID BOND (SF 24)PERFORMANCE BOND (SF25)SUPPLEMENTAL LEASE AGREEMENT (SF 276)CERTIFICATE OF CURRENT COST OR PRICING DATACERTIFICATE OF BUILDING ENERGY PERFORMANCEPart VIII -- FormsLessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


Refer to Part I Section 10 and the Form 1364 Guidance for instructions on completing this form.PROPOSAL TO LEASE SPACE(For use with TI <strong>SFO</strong> and/or National BrokerContract)IN RESPONSE TOSOLICITATIONNUMBER SECTION I - DESCRIPTION OF PREMISES1a. BUILDING NAME 2a. FLOORSOFFERED1b. BUILDING ADDRESS 2b. TOTALNUMBER OFFLOORS INa. GENERALPURPOSE(<strong>Office</strong>)DATED3. TOTAL RENTABLE SPACEb. WAREHOUSE c. OTHERBUILDING sq. ft. sq. ft. sq. ft.1c. CITY 1d. STATE 4. LIVE FLOORLOAD1e. 9-DIGIT ZIP CODE 1f. CONGRESSIONAL DISTRICT lbs. / sq.ft.8.a. ANNUAL RENTALFull Service Leaseb. OPERATINGCOSTS(SERVICE COSTS)c. CURRENT REALESTATE TAXd. AMORT. OFTENANTIMPROVEMENTSANSI/BOMAOFFICE AREASQUARE FEET5. MEASUREMENTMETHODANSI/BOMA [ ]OTHER [ ]SECTION II - SPACE OFFERED AND RATESRENTABLESQUARE FEETCOMMONAREAFACTORSQ. FT. RATEPER YEAR(RENTABLE)INITIAL TERMTOTAL ANNUALAMOUNT(2) x (4)(1) (2) (3) (4) (5)(Refer to Line 27 on GSA Form 1217) $ $Include in Shell Rent and Provide Current YearStatement (Refer to Line 28 on GSA Form 1217)(Complete items 9a thru 10)[10 divided by 8a(2)]$(see 10)$6. YEAR OF LASTMAJORRENOVATION(if applicable)9. SPACE BUILDOUT &AMORTIZATIONa. TOTALBUILDOUTb. SHELLBUILDOUT(Perrequirementsin <strong>SFO</strong>)c. TENANTIMPROVEMENTS(Perrequirementsin <strong>SFO</strong>)7. BUILDINGAGE$$DOLLARAMOUNT(Excluding 9brequirements)$d. AMORT. RATE %e. SHELL RENTAL 8a(5) minus sum <strong>of</strong> [8b(5) and 8d(5)] $ $ e. AMORT. TERM MONTHS11.12.13.Note: When multiplying column 4 by column 2, it may not equal column 5, due to rounding. The Offeror is encouraged tominimize the rounding error.Tenant Improvements shall be all alterations for the Government-demised area above the building shell build out. TheTenant Improvement Allowance as stated under Block 9c is not included in the shell rent. It is expected that the tenant buildout will be fully amortized at the end <strong>of</strong> the firm term and the rent reduced accordingly. Any desired rent increases ordecreases should be reflected in the shell rate and fully explained as part <strong>of</strong> this written proposal. If tenant improvementsare to be amortized beyond the firm term, said calculations will be itemized as part <strong>of</strong> this written proposal.f. AMORT. OFTENANTIMPROVEMENTS(Use 9c as10. AMORT. OFTENANTIMPROVEMENTSCOMMISSIONSa. Tenant Representative Commission: b. Owner’s Representativec. Schedule <strong>of</strong> Commission payments:%Commission:% % at lease award and/or % at lease occupancya. Number <strong>of</strong> parking spaces forthe entire building/facility,which are under the control <strong>of</strong>the Offeror:b. Number <strong>of</strong> parking spacesfor Official GovernmentVehicles (per <strong>SFO</strong>):Annual cost per space:c. Number <strong>of</strong> parking spaces for Employee/Visitor Use:$$(per month)(9f X 12 months)(per year)Annual cost per space: $$ Number required by local code:SECTION III - LEASE TERMS AND CONDITIONS14. INITIAL LEASE TERM (Full Term)) 15. RENEWAL OPTIONSa. NUMBER OFYEARSb. YEARS FIRMc. NUMBER OF DAYSNOTICE REQUIREDFOR GOVERNMENTTO TERMINATELEASE:a. SHELL RATE/RSF / YRb. YEARSEACHc. NUMBER OFOPTIONSd. NUMBER OF DAYSNOTICE REQUIREDTO EXERCISERENEWAL OPTION:$PAGE 1 OF 2 GSA FORM 1364A (REV 12/04)Part VIII: FormsLessor __________ Gov’t. __________ __________ <strong>of</strong> __________Pages


Refer to Part I Section 10 and the Form 1364 Guidance for instructions on completing this form.16. OFFER GOOD UNTIL AWARD(In accordance with Federal Acquisition Regulations 15.208)18. LIST OF ATTACHMENTS SUBMITTED WITH THIS OFFER (See Solicitation requirements)17. Space will be altered and delivered in accordance with the Government'sspecifications and requirements in accordance with the Solicitation for Offers andany additional attachments.19. ADDITIONAL REMARKS OR CONDITIONS WITH RESPECT TO THIS OFFER20. RECORDED OWNER (Name and address including ZIP code)NAMESTREETCITY, ST ZIPSECTION IV - OWNER IDENTIFICATION AND CERTIFICATION21. BY SUBMITTING THIS OFFER, THE OFFEROR AGREES UPON ACCEPTANCE OF THIS PROPOSAL BY THE HEREIN SPECIFIED DATE, TO LEASE TO THEUNITED STATES OF AMERICA, THE PREMISES DESCRIBED, UPON THE TERMS AND CONDITIONS AS SPECIFIED HEREIN, IN FULL COMPLIANCE WITH ANDACCEPTANCE OF THE AFOREMENTIONED SOLICITATION FOR OFFERS, WITH ATTACHMENTS.22. OFFEROR’S INTEREST IN PROPERTY OWNER AGENT OTHER(Specify):23. OFFEROR[ ] [ ]a. NAMETITLESTREETCITY, ST ZIPb. E-MAIL ADDRESS:c. TELEPHONE NUMBER (Including area code)( ) - extensiond. SIGNATURE e. DATE SIGNEDPAGE 2 OF 2 GSA FORM 1364A (REV 12/04)Lessor __________ Gov’t. __________Part VIII: Forms__________ <strong>of</strong> __________ Pages


GSA FORM 1364A – PROPOSAL TO LEASE SPACE GUIDANCEAny and all references to ANSI/BOMA square feet on GSA forms should be read as NUSF forthe purpose <strong>of</strong> this solicitation.I. SECTION I -DESCRIPTION OF PREMISESBlock 1aBuilding NameThe Offeror should provide the building name <strong>of</strong> the proposed facility/building, to house the Government's spacerequirement, if applicable.Block 1bBuilding AddressThe Offeror must provide the building address <strong>of</strong> the proposed facility/building, to house the Government's spacerequirement.Block 1cBuilding CityThe Offeror must provide the name <strong>of</strong> the City the proposed facility/building is located.Block 1dBuilding StateThe Offeror must provide the name <strong>of</strong> the State or U.S. Territory the proposed facility/building is located.Block 1eBuilding 9-Digit Zip CodeThe Offeror must provide the 9-Digit United States Postal Service Zip Code for the address <strong>of</strong> the proposedfacility/building.The 9-Digit Zip Code can be found on the United States Postal Service Web Site either onhttp://zip4.usps.com/zip4/welcome.htm or http://www.usps.com/Block 1fBuilding's Congressional DistrictThe Offeror must provide the Congressional District where the proposed facility/building is located.The Congressional District can be found on the United States House <strong>of</strong> Representatives Web Site http://www.house.gov/Block 2aSpecific Floors OfferedThe Offeror must specifically identify the floor(s) <strong>of</strong>fered in his/her building.Block 2bTotal Number <strong>of</strong> Floors in BuildingThe Offeror must provide the total number <strong>of</strong> floors in the building.Block 3aTotal Rentable Square FeetIf the building/facility <strong>of</strong>fered is a general-purpose <strong>of</strong>fice and/or retail facility, the Offeror must provide the total rentablesquare feet <strong>of</strong> space being <strong>of</strong>fered to house the Government's space requirement. Rentable space is the area for which atenant is charged rent. The rentable square feet are determined by the building owner and agreed to by the Contracting<strong>Office</strong>r. The rentable space may include a share <strong>of</strong> building support/common areas such as elevator lobbies, buildingcorridors, and floor service areas. Floor service areas typically include restrooms, janitor rooms, telephone closets,electrical closets, and mechanical rooms. The rentable space does not include vertical building penetrations and theirenclosing walls, such as stairs, elevator shafts, and vertical ducts.Block 3bTotal Rentable Square FeetIf the building/facility <strong>of</strong>fered was constructed as a warehouse, the Offeror must provide the total rentable square feet <strong>of</strong>space being <strong>of</strong>fered to house the Government's space requirement.Block 3cTotal Rentable Square FeetIf other space is being <strong>of</strong>fered as part <strong>of</strong> the proposal, i.e., storage space within an <strong>of</strong>fice and/or retail facility, the Offerorshould differentiate and provide the total rentable square feet being <strong>of</strong>fered to the Government under Block 3c. Please notethat storage space within an <strong>of</strong>fice and/or retail facility is not warehouse space.


Block 4Live Floor LoadThe proposal must include the live load capacity <strong>of</strong> the space <strong>of</strong>fered to the Government. <strong>Office</strong> areas shall have aminimum live load capacity <strong>of</strong> 50 pounds per ANSI/BOMA <strong>Office</strong> Area square foot plus 20 pounds per ANSI/BOMA <strong>Office</strong>Area square foot for moveable partitions. Storage areas shall have a minimum live load capacity <strong>of</strong> 100 pounds perANSI/BOMA <strong>Office</strong> Area square foot including moveable partitions. A report showing the floor load capacity, at no cost tothe Government, by a registered pr<strong>of</strong>essional engineer may be required. Calculations and structural drawings may also berequired. Please note that warehouse requirements require additional floor load capacity.Block 5Measurement MethodThe Offeror must identify their method <strong>of</strong> measurement for the <strong>Office</strong> Area, which means "the area where a tenant normallyhouses personnel and/or furniture, for which a measurement is to be computed." The Government recognizes theAmerican National Standards Institute/Building Owners and Managers Association (ANSI/BOMA) international standard(Z65.1-1996) definition for <strong>Office</strong> Area. ANSI/BOMA <strong>Office</strong> Area square feet shall be computed by measuring the areaenclosed by the finished surface <strong>of</strong> the room side <strong>of</strong> corridors (corridors in place as well as those required by local codesand ordinances to provide an acceptable level <strong>of</strong> safety and/or to provide access to essential building elements) and otherpermanent walls, the dominant portion (refer to Z65.1) <strong>of</strong> building exterior walls, and the center <strong>of</strong> tenant-separatingpartitions. Where alcoves, recessed entrances, or similar deviations from the corridor are present, ANSI/BOMA <strong>Office</strong> Areasquare feet shall be computed as if the deviation were not present.Block 6Year <strong>of</strong> Last Major RenovationThe Offeror should provide the date <strong>of</strong> the last building renovation, if applicable.Block 7Building AgeThe Offeror must identify the facility/buildings age or the year the building was constructed.II.SECTION II-SPACE OFFERED AND RATESBlock 8a(1)ANSI/BOMA <strong>Office</strong> AreaThe Offeror must provide the total ANSI/BOMA <strong>Office</strong> Area square feet <strong>of</strong> space being <strong>of</strong>fered to house the Government'sspace requirement. The Government recognizes the American National Standards Institute/Building Owners andManagers Association (ANSI/BOMA) international standard (Z65.1-1996) definition for <strong>Office</strong> Area. ANSI/BOMA <strong>Office</strong>Area square feet shall be computed by measuring the area enclosed by the finished surface <strong>of</strong> the room side <strong>of</strong> corridors(corridors in place as well as those required by local codes and ordinances to provide an acceptable level <strong>of</strong> safety and/orto provide access to essential building elements) and other permanent walls, the dominant portion (refer to Z65.1) <strong>of</strong>building exterior walls, and the center <strong>of</strong> tenant-separating partitions. Where alcoves, recessed entrances, or similardeviations from the corridor are present, ANSI/BOMA <strong>Office</strong> Area square feet shall be computed as if the deviation werenot present.Block 8a(2)Rentable Square FeetThe Offeror must provide the total rentable square feet <strong>of</strong> space being <strong>of</strong>fered to house the Government's spacerequirement. Rentable space is the area for which a tenant is charged rent. It is determined by the building owner and mayvary by city or by building within the same city. The rentable space may include a share <strong>of</strong> building support/common areassuch as elevator lobbies, building corridors, and floor service areas. Floor service areas typically include restrooms,custodial rooms, telephone closets, electrical closets, and mechanical rooms. The rentable space does not include verticalbuilding penetrations and their enclosing walls, such as stairs, elevator shafts, and vertical ducts.Block 8a(3)Common Area Factor -(Rentable I (ANSI/BOMA <strong>Office</strong> Area) Factor)The Offeror must provide the Common Area Factor (a conversion factor(s) determined by the building owner and appliedby the Offeror to the ANSI/BOMA <strong>Office</strong> Area square feet to determine the rentable square feet for the <strong>of</strong>fered space). Theequation is rentable square feet divided by ANSI/BOMA <strong>Office</strong> Area square feet.If the space <strong>of</strong>fered is on multiple floors and does not have a single common area factor because <strong>of</strong> changes in floordesign due to building architecture/building systems or due to full floor and partial floor occupancy under the same leaseproposal, the Government requests the common area factors itemized by location and by floor. If the <strong>of</strong>fer is the successful<strong>of</strong>fer, the Government, on a case-by-case basis, may request to have one common area factor, which would be theblended/averaged common area factor. This blended/averaged common area factor may be placed on contractdocuments, for internal Government purposes.If the product <strong>of</strong> rentable square feet divided by ANSI/BOMA <strong>Office</strong> Area square feet does not round evenly, theGovernment requests that the result be provided up to 9 decimal places.


Block 8a(4)Annual Rate per Rentable Square FootThe Offeror must provide annual rate per rentable square foot, including any and all services, utilities and ownership costsidentified on the GSA Form 1217, plus all requirements specified in the Solicitation for Offers and its attachments includingany tenant improvement allowance(s).The rate may be levelized or stepped, but the Offeror must identify if the rate is levelized or must itemize the stepincreases.Block 8a(5)Total Annual RentalThe Offeror must calculate the total annual rent based upon multiplying Block 8a(2) by 8a(4). When multiplying Block 8a(4)by Block 8a(2), it may not equal the proposed total annual rent in 8(a)5. The Offeror is encouraged to minimize therounding error.Block 8b(4)Operating Cost per Rentable Square FootThe Offeror must provide any and all services, utility expenses, excluding ownership and managerial costs, on a first leaseyear rentable square foot basis. This amount is identified on Line 27 on the GSA Form 1217.Block 8b(5)Annual Base Operating CostThe Offeror must provide any and all services, utility expenses, excluding ownership and managerial costs, on a first leaseyear total annual cost basis. This amount is identified on Line 27 on the GSA Form 1217.Block 8d(4)Amortization <strong>of</strong> TIA per Rentable Square FootIf the Solicitation for Offers requires a Tenant Improvement Allowance, the Offeror must complete Block 9(c}, Block 9(d},Block 9(e}, Block 9(f}, and Block 10. Block 8d(4} requires the Annual Amortization <strong>of</strong> the Tenant Improvements to bedivided by the rentable square footage in Block 8a(2}.Block 8d(5)Amortization <strong>of</strong> TlA per AnnumIf the Solicitation for Offers requires a Tenant Improvement Allowance, the Offeror must complete Block 9(c}, Block 9(d},Block 9(e}, Block 9(f}, and Block 10. Block 8d(5} requires the Annual Amortization <strong>of</strong> the Tenant Improvements same asBlock 10.Block 8e(4)Shell Rate per Rentable Square FootThe proposal must include a lease rate per rentable square foot for the building shell rental. All improvements in the basebuilding, lobbies, common areas, and core areas shall be provided by the Offeror, at the Offeror's expense. This rate shallinclude, but not limited to, property financing (exclusive <strong>of</strong> Tenant Improvement), insurance, taxes, management, pr<strong>of</strong>it.capital expenditures, etc., for the building. The building shell rental rate shall also include all basic building systems andcommon area build-out, including base building lobbies, common areas, and core areas, etc., exclusive <strong>of</strong> the ANSI/BOMA<strong>Office</strong> Area space <strong>of</strong>fered as required in the Solicitation for Offers. The calculation for Block 8e(4} should equate to Block8a(4} minus the sum <strong>of</strong> [8b(4} and 8d(4)].Block 8e(5)Shell Rent per AnnumThe proposal must include the building shell rental. All improvements in the base building, lobbies, common areas, andcore areas shall be provided by the Offeror, at the Offeror's expense. This rent shall include, but not limited to, propertyfinancing (exclusive <strong>of</strong> tenant improvement), insurance, taxes, management, pr<strong>of</strong>it, capital expenditures, etc., for thebuilding. The building shell rental rate shall also include all basic building systems and common area build-out, includingbase building lobbies, common areas, and core areas, etc., exclusive <strong>of</strong> the ANSI/BOMA <strong>of</strong>fice area space <strong>of</strong>fered asrequired in the solicitation for <strong>of</strong>fers. The calculation for Block 8e(5} should equate to Block 8a(5} minus the sum <strong>of</strong> [8b(5}and 8d(5}].Block 9aTotal Buildout CostsThe Offeror must not include build-out costs affiliated with shell in the tenant improvement allowance costs. The purposefor this block is to quantify the total tenant area build-out costs, in the Government-demised area, to ensure any shell buildoutcosts are subtracted out in Block 9b. All improvements in the base building, lobbies, common areas, and core areasshall be provided by the Offeror, at the Offeror's expense. This block is as required by the GSA contracting <strong>of</strong>ficer.Block 9bShell Buildout CostsThe Offeror must not include build-out costs affiliated with shell in the tenant improvement allowance costs. Building shellrequirements are defined in the solicitation for <strong>of</strong>fers. The Offeror, at the Offeror's expense, must provide any and all costsrequired to satisfy the government's space requirement that is affiliated with the building shell. The building shell costs arededucted from the total tenant build out costs prior to determining the government's tenant improvement costs in Block 9c.This block is as required by the GSA contracting <strong>of</strong>ficer.


Block 9cTIA provided per <strong>SFO</strong>If the government requires a tenant improvement allowance as part <strong>of</strong> the solicitation for <strong>of</strong>fers, the Offeror must providethe total tenant improvement allowance as part <strong>of</strong> the rental consideration. The tenant improvement allowance shall beused for building out the government-demised area in accordance with the government-approved design intent drawings.The successful Offeror, as part <strong>of</strong> the rental consideration, shall perform all tenant improvements required by thegovernment for occupancy, and all improvements shall meet the quality standards and requirements <strong>of</strong> the solicitation for<strong>of</strong>fers, its attachments, and GSA Form 3517, General Clauses.The tenant improvement allowance shall include all the Offeror's administrative costs, general contractor fees,subcontractor's pr<strong>of</strong>it and overhead costs, Offeror's pr<strong>of</strong>it and overhead, design costs, and other associated project feesnecessary to prepare construction documents to complete the tenant improvements. It is the successful Offeror'sresponsibility to prepare all documentation (working drawings, etc.) required to receive construction permits. No costsassociated with the building shell shall be included in the tenant improvement pricing.The tenant improvement allowance dollars are defined and specified in the Solicitation for Offers or the government's leaserequirements. The tenant improvement allowance is based upon and calculated by using the ANSI/BOMA <strong>Office</strong> Areasquare footage.Block 9dAmortization RateIf the Offeror includes a tenant improvement allowance as part <strong>of</strong> the proposal, the Offeror must provide his/her annualamortization interest rate used to finance the tenant improvement allowance. The amortization interest rate should bebased upon existing market conditions using the United States prime rate, the London interbank <strong>of</strong>fered rate (known as theLlBOR), and/or yields on United States Treasury securities for the term <strong>of</strong> the amortization period.Block 9eAmortization TermIf the Offeror includes a tenant improvement allowance as part <strong>of</strong> the proposal, the Offeror must provide his/heramortization term in months. Unless inappropriate or negotiated in a different way by the Contracting <strong>Office</strong>r, the term mostlikely will be the firm term as defined by the Solicitation for Offers and its attachments.Block 9fAmortization <strong>of</strong> TIA, MonthlyIf the Offeror includes a tenant improvement allowance as part <strong>of</strong> the proposal, the Offeror must calculate a standard, levelamortization on a monthly basis in arrears using Block 9c as the principal amount, Block 9d as the amortization interestrate, and Block 9e as the amortization term. No costs associated with the building shell shall be included in theamortization.Block 10Amortization <strong>of</strong> TIA, AnnuallyIf the Offeror includes a tenant improvement allowance as part <strong>of</strong> the proposal, the Offeror is requested to multiply Block 9fby 12 to calculate the annual amortization. If the term <strong>of</strong> the lease or if the term <strong>of</strong> the amortization period in the last yeardoes not evenly equate to a full year, the Offeror should make note and itemize the last year amortization figure separately.Block 11TIA per<strong>SFO</strong>The Offeror is reminded that tenant improvements shall provide for all alterations for the government-demised area abovethe building shell build-out. It is anticipated that the tenant build-out will be fully amortized at the end <strong>of</strong> the firm term. Anydesired rent increases or decreases should be reflected in the shell rate and fully explained as part <strong>of</strong> this written proposal.If tenant improvements are to be amortized beyond the firm term, said calculations will be itemized as part <strong>of</strong> this writtenproposal.Block 12aTenant Representative CommissionIf GSA uses an authorized Realty Company as its <strong>of</strong>ficial tenant representative, the Offeror must provide the totalpercentage <strong>of</strong> commission allocated in the pr<strong>of</strong>orma, for this proposal, to the tenant representative/tenant broker. Thisinformation is necessary to measure the national broker contract program results.The General Services Administration (GSA) may designate an authorized Realty Company as the Government'srepresentative. While a GSA Contracting <strong>Office</strong>r must execute the lease agreement, the authorized Realty Company willbe entitled to the tenant representative/tenant broker commission, which is a common commercial real estate businesspractice. Such commission shall be payable to the authorized Realty Company in the form <strong>of</strong> a check due in accordancewith local laws and customs but no later than the lease commencement date.Under the terms <strong>of</strong> the contract between GSA and the authorized Realty Company, the authorized Realty Company willforego a certain percentage previously agreed to by the authorized Realty Company. The Offeror will apply the percentageforegone by the authorized Realty Company as a credit to the Shell Rent <strong>of</strong> the lease (herein, commission credit). Saidcredit will ultimately be reflected in a reduction to the shell rent on the Standard Form 2, entitled "U.S Government Leasefor Real Property."The Solicitation for Offers will state the percentage forgone by the authorized Realty Company.


For purposes <strong>of</strong> the price evaluation, any commission credits shall be treated as a lump sum credit and will be evaluated inaccordance with the procedures established in the "Price Evaluation" paragraph in the SUMMARY section <strong>of</strong> theSolicitation for Offers. The commissions paid to the GSA authorized Realty Company, as direct payment, will not beapplied to the present value analysis.A pr<strong>of</strong>orma is defined as the ownerships' projected financial analysis on their income and expenses in determining theirproposal to the Government.Block 12bOwner's Representative CommissionIf GSA uses an authorized Realty Company as its <strong>of</strong>ficial tenant representative, the Offeror must provide the totalpercentage <strong>of</strong> commission allocated in the pr<strong>of</strong>orma, for this proposal, to the owner's representative/owner's broker. Thisblock is to gather information and measure the national broker contract program results.Block 12cSchedule <strong>of</strong> Commission PaymentsIf GSA uses an authorized Realty Company as its <strong>of</strong>ficial tenant representative, the Offeror must provide the schedule <strong>of</strong>commission payments as allocated in the pr<strong>of</strong>orma, for this proposal. Under the terms <strong>of</strong> the contract between GSA andthe authorized Realty Company, the authorized Realty Company will forego a certain percentage referenced above as thecommission credit as part <strong>of</strong> the Realty Companies contract with GSA. The remaining commission shall be payable to theauthorized Realty Company in the form <strong>of</strong> a check due in accordance with local laws and customs but no later than thelease commencement date. This block is to gather information on the timing <strong>of</strong> commission payments to measure thenational broker contract program results.Block 13aTotal Available ParkingThe Offeror shall provide the number <strong>of</strong> parking spaces for the entire building/facility, which are under the control <strong>of</strong> theOfferor. If the <strong>of</strong>fered building shares parking with neighboring buildings the Offeror is requested to give the total number <strong>of</strong>surface and/or structured parking available along with the total number <strong>of</strong> parking spaces surface and/or structuredallocated to the <strong>of</strong>fered building.Block 13bParking required by <strong>SFO</strong>If the Solicitation for Offers and its attachments requires parking for <strong>of</strong>ficial government vehicles, the Offeror must provideas part <strong>of</strong> the proposal the number <strong>of</strong> parking spaces provided for <strong>of</strong>ficial government vehicles along with the annual costper space. The Offeror must specify whether the annual cost remains level over the entire term or itemize any steps in theannual cost over the term <strong>of</strong> the proposal.Block 13cParking Available for General UseThe Offeror shall provide the number <strong>of</strong> parking spaces, surface and/or structured, available for Government employeeand/or visitor use. Government employees and visitors are typically responsible for coordinating and funding their ownparking arrangements; however, the Government requests the number <strong>of</strong> available parking spaces for Governmentemployees and/or visitors, the annual cost, and the number required by local code, to ensure appropriate accommodationhas been made as part <strong>of</strong> the lease proposal.III. SECTION III -LEASE TERMS AND CONDITIONSBlock 14aNumber <strong>of</strong> Years for InitialTerm The Offeror is requested to confirm that the total initial term <strong>of</strong> the proposal is consistent with the Solicitation forOffers and its attachments.Block 14bInitial Firm Term in YearsThe Offeror is requested to confirm that the firm term portion <strong>of</strong> the total initial term <strong>of</strong> the proposal is consistent with theSolicitation for Offers and its attachments. Block 14a may be the same as Block 14b, as defined by the Solicitation forOffers and its attachments.Block 14cDays Notice to TerminateIf the Solicitation for Offers requires, or if the Offeror provides termination rights during the term <strong>of</strong> the proposed lease, theOfferor must provide the number <strong>of</strong> days notice required for the Government to terminate the proposed lease.Block 15aRenewal Option Shell RateIf the Solicitation for Offers requires a renewal option, the renewal options will be evaluated in accordance with theSolicitation for Offers. Block 15a requests the shell rate per rentable square foot proposed by the Offeror.The Offeror is reminded that the Government anticipates that the tenant build-out will be fully amortized at the end <strong>of</strong> thefirm term. Any desired rent increases or decreases should be reflected in the shell rate and fully explained as part <strong>of</strong> this


written proposal.If the Offeror submits an unsolicited renewal option, the Offeror understands that even if his/her <strong>of</strong>fer is the successful <strong>of</strong>ferthe Contracting <strong>Office</strong>r, may choose not to incorporate the renewal option into the lease language.Please note procurement and appropriation regulations may prevent GSA from incorporating a renewal option into thelease agreement and may prevent GSA from ultimately exercising a renewal option written into the lease agreement.Block 15bRenewal Option TermThe Offeror is requested to confirm that the renewal term <strong>of</strong> the proposal is consistent with the Solicitation for Offers and itsattachments. If the Solicitation for Offers requested more than one renewal term, the Offeror is requested to confirm thatthe renewal terms <strong>of</strong> the proposal are consistent with the Government's requirement.Block 15cNumber <strong>of</strong> Renewal OptionsThe Offeror is requested to confirm that the number <strong>of</strong> renewal option periods reflected in this proposal is consistent withthe Solicitation for Offers and its attachments.Block 15dDays Notice to Exercise Renewal OptionsIf the Solicitation for Offers requires a renewal option, the number <strong>of</strong> days notice required to exercise the renewal option isrequested. The Solicitation for Offers may specify a number <strong>of</strong> days notice as determined by the Contracting <strong>Office</strong>r.Otherwise, the number <strong>of</strong> days notice should be reasonable and in accordance with market conditions.Block 16Offer Good Until AwardOfferors are responsible for submitting proposals, and any revisions, and modifications, so as to reach the appropriateGovernment <strong>of</strong>fice designated by the time specified in the Solicitation for Offers. Regulations regarding the submittal <strong>of</strong>proposals are summarized in Federal Acquisition Regulations 15.208. The Federal Acquisition Regulations can be foundon the Federal Acquisition Institutes web site located at http://www.arnet.gov/far/Block 17Alterations in accordance with <strong>SFO</strong>Space will be altered and delivered in accordance with the Government's specifications and requirements in accordancewith the Solicitation for Offers and any additional attachments. The Contracting <strong>Office</strong>r, or his/her designee, may requirewritten verification that the proposal will comply with the Government's proposed construction schedule and requiredoccupancy date. Proposals unable to meet the terms <strong>of</strong> the Solicitation for Offers may be considered, by the Contracting<strong>Office</strong>r, non-responsive to the Government's requirement.Block 18List <strong>of</strong> Additional AttachmentsThe Offeror may itemize attachments submitted as part <strong>of</strong> his/her proposal as required by the Solicitation for Offers and asnecessary to thoroughly and properly explain his/her <strong>of</strong>fer.Block 19Additional Remarks or CommentsThis block is to be used ot the discretion <strong>of</strong> the Contracting <strong>Office</strong>r to request additional information. Examples include, butare not limited to:• the overtime HVAC rate;• the proposed rental adjustment for vacant premises;• type <strong>of</strong> construction;• real property tax information; and• legal description <strong>of</strong> property proposed.A further example is as prepared below: Total Land Costs $_______________ Total Building Cost $ ________________Total Loan Amount $______________ Interest Rate ________%Estimate Fair Market Value <strong>of</strong> the Building after completion $____________________Current Year Tax Assessment $. __________, Year_______ Improved ____________ Unimproved _____________Percentage <strong>of</strong> Government Occupancy in this Lease _________________ (based on rentable square feet)Total rentable square feet in taxable entity ____________.Is government space part <strong>of</strong> multiple property tax bills_____? If so please specify description and sf for each. _________Copy <strong>of</strong> Current Year Tax Statement _________________________________________________________________________________________________________________________________Legal Description (Must Match Tax Statement):


IV. SECTION IV -OWNER IDENTIFICATION AND CERTIFICATIONBlock 20Name and Address <strong>of</strong> Recorded OwnerThe Offeror must provide the name and full address <strong>of</strong> the recorded owner <strong>of</strong> the property proposed in response to theGovernment's requirement.Block 21Agreement to Lease to the United StatesBy submitting this <strong>of</strong>fer, the Offeror agrees upon acceptance <strong>of</strong> this proposal by the herein specified date, to lease to theUnited States <strong>of</strong> America, the premises described, upon the terms and conditions as specified herein, in full compliancewith and acceptance <strong>of</strong> the aforementioned Solicitation for Offers, with attachments.Block 22Offeror'S Interest in the PropertyThe Offeror must identify their interest in the property, whether they have an ownership interest, they are an agent, orsome other relationship to the property being proposed in response to the Government's requirement.Block 23Offeror InformationThe proposal must include the Offeror's name, title, address, email address, phone, signature and date <strong>of</strong> signature.The Contracting <strong>Office</strong>r may request an authority to represent letter from the ownership identifying the Offeror as his/her<strong>of</strong>ficial representative.


SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]THIS PAGE INTENTIONALLY LEFT BLANK FOR REPRODUCTION PURPOSES.Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]PAST PERFORMANCE SURVEY FORM1. Name and Address <strong>of</strong> Contracting Activity:2. Contract Number: _____________________________3. Contract Type (Check all that apply): Negotiated_________ Sealed Bid_________Other________(Identify Other)_________________________4. Total Contract Amount:___________________Status: Active_______ Complete__________5. Date <strong>of</strong> Award: _________________________Contract Completion Date (including any extensions):__________________6. Description and Location <strong>of</strong> Work:7. List <strong>of</strong> Major Subcontractors:8. Contracting <strong>Office</strong>r (CO) or Individual Responsible for Signing Contract andTelephone/FAX Numbers:9. Project Manager and Telephone/FAX Numbers:10. Resident Engineer/CO’s Technical Representative or <strong>Construction</strong> Supervisor andTelephone/FAX Numbers:11. Administrative Contracting <strong>Office</strong>r or Individual Responsible for Administering theContact, if different from #8 above, and Telephone/FAX Numbers:A SEPARATE RECORD MUST BE COMPLETED FOR EACH CONTRACT ANDSUBCONTRACT PERFORMED BY THE OFFEROR AND KEY PERSONNEL DURING THEPAST THREE (3) YEARS, AS WELL AS THOSE CURRENTLY IN PROGRESS.Part VIII: FormsLessor __________ Gov’t. ____________________ <strong>of</strong> __________ PagesPAST PERFORMANCE SURVEY FORM


SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]THIS PAGE INTENTIONALLY LEFT BLANK FOR REPRODUCTION PURPOSES.Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]CERTIFICATE OF CURRENT COST OR PRICING DATAThis is to certify that, to the best <strong>of</strong> my knowledge and belief, the cost or pricing data (as defined in section2.101 <strong>of</strong> the Federal Acquisition Regulation (FAR) and required under FAR subsection 15.403-4)submitted, either actually or by specific identification in writing, to the Contracting <strong>Office</strong>r or to theContracting <strong>Office</strong>r's representative in support <strong>of</strong> ________* are accurate, complete, and current as <strong>of</strong>________**. This certification includes the cost or pricing data supporting any advance agreements andforward pricing rate agreements between the <strong>of</strong>feror and the Government that are part <strong>of</strong> the proposal.Firm ________________________________________Signature ____________________________________Name _______________________________________Title ________________________________________Date <strong>of</strong> execution*** ___________________________* Identify the proposal, request for price adjustment, or other submission involved, giving the appropriateidentifying number (e.g., RFP No.).**Insert the day, month, and year when price negotiations were concluded and price agreement wasreached or, if applicable, an earlier date agreed upon between the parties that is as close as practicable tothe date <strong>of</strong> agreement on price.*** Insert the day, month, and year <strong>of</strong> signing, which should be as close as practicable to the date whenthe price negotiations were concluded and the contract price was agreed to.Part VIII FormsLessor __________ Gov’t. ____________________ <strong>of</strong> __________ PagesCERTIFICATE OF CURRENT COST OR PRICING DATA


SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]THIS PAGE INTENTIONALLY LEFT BLANK FOR REPRODUCTION PURPOSES.Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]CERTIFICATION OF BUILDING ENERGY PERFORMANCELOCATION:PROJECT TITLE:PROJECT NUMBER:PROJECT MANAGER:I certify that the energy performance <strong>of</strong> the above project fully satisfies the energy efficiencyrequirements <strong>of</strong> DOE regulations, 10 CFR Part 435, "Energy Conservation Voluntary PerformanceStandards for Commercial and Multi-Family High Rise Residential Buildings; Mandatory for New FederalBuildings."_____________________________________NAME & TITLE___________DATEName and Address <strong>of</strong> Architect-Engineer Firm:Title/Position:Pr<strong>of</strong>essional Registration No.:State Where Registered (use seal):Part VIII: FormsLessor __________ Gov’t. ____________________ <strong>of</strong> __________ PagesCERTIFICATION OF BUILDING ENERGY PERFORMANCE


SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]THIS PAGE INTENTIONALLY LEFT BLANK FOR REPRODUCTION PURPOSES.Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]PART IXCONCEPTUAL PLANSPart IX: Conceptual Floor PlansLessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]THIS PAGE INTENTIONALLY LEFT BLANK FOR REPRODUCTION PURPOSES.Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]PART XSITE SPECIFIC INFORMATIONPart X: Site Specific InformationLessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]THIS PAGE INTENTIONALLY LEFT BLANK FOR REPRODUCTION PURPOSES.Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]PART XISCHEDULE F: VA FURNISHED EQUIPMENT GUIDE LISTPart XI: Schedule F –VA Furnished Equipment Guide List– Page 1 <strong>of</strong> 66Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]PART XI: SCHEDULE F – VA FURNISHED EQUIPMENT GUIDE LISTVA FURNISHED EQUIPMENT GUIDE LISTSchedule F is provided as a convenience to Offerors for determining utility, support, and otherinfrastructure requirements that are to be included as part <strong>of</strong> the rental consideration.The following schedule contains a listing <strong>of</strong> all VA furnished equipment items to be installedin the clinic.The equipment items listed in the Schedule F are NOT to be provided by theLessor.Lessor shall provide supporting construction, HVAC systems, utilities, and electricaldistribution in accordance with Paragraph 6.3 <strong>of</strong> Part I <strong>of</strong> the <strong>SFO</strong>.The Excel worksheet for Schedule F is organized by Room Code. Some departmentshave different room names or descriptions for the same room code. All spaces with thesame room code have been grouped together (green highlighted header rows) abovethe listing <strong>of</strong> equipment for the room or space.Part XI: Schedule F –VA Furnished Equipment Guide List– Page 2 <strong>of</strong> 66Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameSurgery-Ambulatory Surgery ANCW1 1 OR: Anesthesia, Workroom and Equip. StorageA5075 Dispenser, Soap, Disposable 1 VVItem DescriptionDisposable soap dispenser. One-handed dispensing operation. Designed to accommodate disposable soap cartridge andvalve. 1A5106 Waste Disposal Unit, Sharpsw/Glove DispenserE0912 Locker, Supply, Med Surg, WallMtd1 VV1 VVThe unit is designed for the disposal <strong>of</strong> sharps and complies with OSHA guidelines for the handling <strong>of</strong> sharps. It shall house a5 quart container and be capable <strong>of</strong> being mounted on a wall. It shall have a glove dispenser attached. The unit shall besecured by a locked enclosure.Medical/Surgical Supply locker, Wall Mounted, Approx 23"W x20"D. THIS TYPICAL INCLUDES:1 Locked Storage Container4 Tray/Shelves5 Drawers, 3"H (76mm)2 Drawers, 6"H (152mm)2 Tray/Shelf DividersDrawer Organizer BinsConsider the need for an E0921 to transport the locker from place to place.11E1500 Rail, MOD, W/MNTD,HX144XDF3200 Clock, Battery, 12" Diameter 1 VV2 VV Wall mounted rail used for hanging (mounting) lockers, shelves drawers on a wall. 2Clock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 1M0630 Anesthesia Apparatus, 3 Gas 1 VVThree gas anesthesia apparatus. Basic unit consists <strong>of</strong> steel cabinet with casters with one shallow, one medium, and onedeep drawer, seven long scale eleven-inch flowmeters, five cylinder yokes, and telescoping absorber post. It includes twocanistermodel carbon dioxide absorber with inhalation and exhalation check valves, switch valve, switch valve elbow,sidearm Vernitrol, flow calculator, mounting kit, ventilator calculator, ventilator and an oxygen piping inlet. Also featuresnitrous oxide fail safe valve kit, aspirator kit, gas evacuator with vacuum and a flow meter safety cover. Used to dispense amixture <strong>of</strong> gases during surgical procedures.1M1801 Computer, Microprocessing,w/Flat Panel Monitor1 VVDesk top microprocessing computer. The unit shall consist <strong>of</strong> a central processing mini tower, flat panel monitor, keyboard,mouse and speakers. The system shall have the following minimum characteristics: a 2.8 GHz Pentium processor; 512 MBmemory; 80GB hard drive; 32/48x CD-ROMDVD combo; a 3.5" floppy drive; 1.44MB network interface card; video 32 MBNVIDIA; a 15 inch flat panel color monitor. The computer is used throughout the facility to input, manipulate and retrieveinformation.1M1825 Printer, Computer 1 VVM3150 Distribution System,Medication, Automatic1 VVM8800 Cart, Anesthesia 1 VVHigh resolution computer printer with a variety <strong>of</strong> type styles and sheet/envelope feeder trays. Database information reflectsnetwork ready, medium duty <strong>of</strong>fice style laser printers. Other types <strong>of</strong> printers (bubble jet, dot matrix, line or plotter) as wellas light or heavy use capabilities are available.An automated dispensing system that provides controlled dispensing, inventory and security. Size and cost will varydependent on number <strong>of</strong> modules selected. 1Mobile anesthesia cart. The cart shall be built <strong>of</strong> stainless steel and mounted on 4" casters for easy mobility. It shall becapable <strong>of</strong> being equipped with bottles holders, adjustable IV pole, storage drawers, shelves and a top bar/rail. 11R7050 Refrigerator, 25 Cubic Feet 1 VVGeneral purpose refrigerator approximately 84x27x37. This unit is corrosion resistant stainless steel. It has a single selfclosing door with safety stops. This refrigerator is generally used in commercial kitchens, hospitals and schools. 1Engineering BMER1 1 Biomedical Engineering Repair ShopF3200 Clock, Battery, 12" Diameter 1 VVClock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 1T8045 Oscilloscope, With Accessories 1 VVA5075 Dispenser, Soap, Disposable AR VVOscilloscope. Characteristics/components include 100 MHz unit; digitizing scope with a fully-functional analog scope that cancontrol data acquisition and a switch-selectable Pre/Post/Mid-triggering with reference to a triggering event. This unit is usedto evaluate electronic equipment faults.Disposable soap dispenser. One-handed dispensing operation. Designed to accommodate disposable soap cartridge andvalve. #VALUE!1______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 3 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameF3200 Clock, Battery, 12" Diameter 2 VVItem DescriptionClock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 2T0015 Defibrillator Analyzer,Automatic, Portable1 VVDefibrillator analyzer. Characteristics/components include automatic and portable with direct reading; accurately verifies theoutput characteristics <strong>of</strong> all defibrillators while simulating the resistance <strong>of</strong> the human body; output energy measured in joulesor watt seconds on two scales <strong>of</strong> 0-200.0 or 0-1000; output energy remains displayed until the reset button is depressed oncethe defibrillator is fired; and output jacks provided for oscilloscope connection to observe defibrillator pulse wave shape. Shallinclude the optional pacemaker testing module if required by the end user. Battery powered models are available.1T0020 Stand, Test, RadiologicalCompliance1 VVT0030 Radiation-Light Field Analyzer 1 VVAdjustable test stand which accepts a test pattern disk for determining radiological tube focal spots. The stand can also beused to determine half layer values and light-radiation field registrations. 1Light and radiation field analyzer for quality assurance testing <strong>of</strong> radiation therapy devices. Unit is self contained and checksthe coincidence <strong>of</strong> light and radiation fields, symmetry <strong>of</strong> radiation field, flatness <strong>of</strong> radiation field, and penumbra size <strong>of</strong> theradiation field. Unit has a built in graphics printer for hard copy output <strong>of</strong> scanned information. 1T0801 Workbench, Electric, LockerBase1 VVElectrical workbench approximately 34" H x 72" W x 36" D. Characteristics/components include removable maple top; withtwo locker units; and four box lockers (each 12" W X 21" D X 15" H) in each locker unit. This workbench is used in wood andmetal workshops. Workbench is a mix and match construction and can be configured to end users needs. 1T8015 Calibrator, Audiometer 1 VVT8020 Generator, Pulse 1 VVT8025 Generator, Function 1 VVAudiometer calibrator system. Characteristics/components include dual-frequency, dual-amplitude capacity for calibratingprecision Type 1 as well as general purpose Type 2 sound level meters; generates four selectable reference outputs at 250and 1000 Hz, each at 94 and 110 dB; and uses a single 9 volt transistor battery. This system is used for hearing tests inhospitals and clinics.Pulse generator. Characteristics/components include four output modes; and complement dual outputs that greatly increaseunit applicability in logic design areas, especially interfacing within a system or to peripherals. The unique output flexibilitywithin the normal and complement modes is particularly useful in logic design or control applications requiring simultaneoussignals.Function generator. Characteristics/components include generated size, triangle and square waveforms; covers 0.2 Hz to 2.0MHz in 7 ranges; voltage controlled amplitude output; 20 dB step attenuator; four digit frequency counter display and ability togenerate low-distortion sine waves which make the unit uniquely appropriate for applications requiring audio signals. 111T8040 Meter, Sound Level 1 VVSound level meter. This is a 27-140 dB sound analyzing device. It is used to analyze precision measurement and analysis <strong>of</strong>sound levels in laboratory, industrial, community, hospitals and audiology clinics. Unit is battery powered. 1T8045 Oscilloscope, With Accessories 1 VVT8055 Wattmeter, Ultrasonic 1 VVOscilloscope. Characteristics/components include 100 MHz unit; digitizing scope with a fully-functional analog scope that cancontrol data acquisition and a switch-selectable Pre/Post/Mid-triggering with reference to a triggering event. This unit is usedto evaluate electronic equipment faults.Ultrasonic wattmeter. Characteristics/components include electronic and mechanical design to provide superior performanceand greater durability; clear Plexiglas tubing on the front panel that allows the operator to immediately determine the liquidlevel within the sealed reservoir; and power measurements that can be conveniently read on the LCD display. This unit is aone-<strong>of</strong>-a-kind instrument used by biomedical repair persons who regularly test therapeutic ultrasound devices. Unit is batterypowered.11AC: Urgent Care BRIT1 1 Observation / Treatment: Infectious Isolation BedroomA5075 Dispenser, soap 1 VV Dispenser, soap, liquid, wall mounted 1X3930 Illuminator, x-ray film 1 VV Illuminator, x-ray film, 120 volts, wall mounted, individual switch for two, 14” x 17” (350 mm x 425 mm) radiographs, 31” W x20” H (775 mm W x 500 mm H) 1M7401 light, examining 1 VV Light, examining, portable, 120 volts, approx. 18” diameter x 75” H (450 mm diameter x 1875 mm H) 1M1801 CRT, computer system 1 VV CRT, computer system, with keyboard 1M4100 Sphygmomanometer, wall 1 VV Sphygmomanometer, wall hung 1M4200 Otoscope, h wall hung 1 VV Otoscope, wall hung 1______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 4 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameItem DescriptionM4200 Ophthalmoscope, wall hung 1 VV Ophthalmoscope, wall hung 1F2300 Magazine/literature rack 1 VV Magazine/literature rack, wall mounted 1F3200 Clock, atomic 1 VV Clock, atomic, battery operated 1A5106 Sharps container, wall mounted 1 VV Sharps container, wall mounted 1A5106 Glove dispenser, wall mounted 1 VV Glove dispenser, wall mounted 1AC: Urgent Care BRUN1 12 Observation / Treatment: Monitored BedM7845 Monitor, physiological AR VV Monitor physiological, ECG, HRT, BP, OX #VALUE!A5106 Sharps container AR VV Sharps container, wall mounted #VALUE!A5106 Glove dispenser AR VV glove dispenser, wall mounted #VALUE!X3930 Illuminator, x-ray film AR VV 120 volts, wall mounted, individual switch for two, 14"x17" (350mmx425mm) radiographs, 31"Wx20"H (775mm Wx500mm H) #VALUE!M7401 Light, examining portable AR VV 120 volts, 18" diameter x 75" H (450mm diameter x 1875mm H) #VALUE!M4200 Ophthalmoscope AR VV Ophthalmoscope, wall hung #VALUE!M4200 Otoscope AR VV Otoscope, wall jung #VALUE!M4100 Sphygmomanometer, Aneroid, AR VV Sphygmomanometer, wall hung Wall Mounted#VALUE!F0340 Stool AR VV Stool, examining, adjustable #VALUE!Canteen Service BX001 1 Vending Machine Area and SeatingA6030 Machine, Vending AR VV This JSN is to be used for determining and defining the requirement for vending machines. Item is normally supplied byCanteen Service. #VALUE!AC: HAS (MAS) CASH1 1 Agent CashierA6035 Repository, Night, With Safe 1 VV Constructed <strong>of</strong> high tensile steel body and jam designed to maximize protection against pry attack. Top or front loaddepository features a large hopper made <strong>of</strong> formed heavy duty steel, handle activated and designed for smooth money dropE0123 Workstation, Straight, FreeStanding, 72" W1 VVF3200 Clock, Battery, 12" Diameter 1 VVoperation and large package capacity. Deposit drawer features a large fish-resistant pull out drawer deposit directly intostandard interior locker.This JSN will provide a whole work station typical to quickly plan work in areas in clinical or administrative spaces. There willbe a price decrease if typical work stations are used with vertical hanging strips instead <strong>of</strong> panels. THIS TYPICALINCLUDES:4 Standard Solid Panels2 Panel Connectors, 2-Way Corner1 Panel-to-Panel Connector2 Finished End Hardware1 Cantilevered, Work Surface2 Lockable Flipper Units2 Shelf, Storage/Displays2 Lights1 Tack board1 Tool Rail1 Paper Tray1 Diagonal Tray1 Adjustable Keyboard Tray1 Mobile Pedestal, Box/FileClock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 111______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 5 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameM1801 Computer, Microprocessing,w/Flat Panel Monitor1 VVItem DescriptionDesk top microprocessing computer. The unit shall consist <strong>of</strong> a central processing mini tower, flat panel monitor, keyboard,mouse and speakers. The system shall have the following minimum characteristics: a 2.8 GHz Pentium processor; 512 MBmemory; 80GB hard drive; 32/48x CD-ROMDVD combo; a 3.5" floppy drive; 1.44MB network interface card; video 32 MBNVIDIA; a 15 inch flat panel color monitor. The computer is used throughout the facility to input, manipulate and retrieveinformation.1M1825 Printer, Computer 1 VVM1805 Copier, Desk Top 1 VVHigh resolution computer printer with a variety <strong>of</strong> type styles and sheet/envelope feeder trays. Database information reflectsnetwork ready, medium duty <strong>of</strong>fice style laser printers. Other types <strong>of</strong> printers (bubble jet, dot matrix, line or plotter) as wellas light or heavy use capabilities are available.Desk top copier. Copier consists <strong>of</strong> two tray paper supply with clip tray, sort indicator, two page copy indicator, automaticpaper selection and frame eraser with zoom capabilities. For use where low volume reproduction is required. 11AC: Patient Education (Pat EDU) CLR02 1 ClassroomAC: Nutrition (Dietetics) CLR02 1 ClassroomM1825 Printer, Computer 1 VVA6046 Artwork, Decorative, WithFrameF0835 Stand, Projection 1 VVHigh resolution computer printer with a variety <strong>of</strong> type styles and sheet/envelope feeder trays. Database information reflectsnetwork ready, medium duty <strong>of</strong>fice style laser printers. Other types <strong>of</strong> printers (bubble jet, dot matrix, line or plotter) as wellas light or heavy use capabilities are available.1 VV This JSN is to be used for determining and defining location <strong>of</strong> decorative artwork. 2Mobile projection stand with electrical outlet. Equipped with four (4) swivel casters with anti-shimmy spring cups, nonmarkingwheels, two (2) locking, and shelf storage. Convenience outlet required at point <strong>of</strong> use. 21F2100 Lectern, Mobile, With ReadingLight1 VVF2225 Projector, Overhead 1 VVPortable floor lectern with reading light and self-contained audio. May use 110V or batteries (not included). Convenienceoutlet required if not using batteries. 2Overhead transparency projector with hi-low lamp switch, thermal safety switch and 15 foot power cord. Convenience outletrequired at point <strong>of</strong> use. 2F3200 Clock, Battery, 12" Diameter 1 VVClock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 2M0385 Projector, Multimedia/Data 1 VVM0415 Projector, Slide, Carousel 1 VVThe projector shall provide computer and video projections. Minimum features included:Brightness <strong>of</strong> not less than 600 ANSI ( American National Standards Institute) Lumens, and a minimum resolution format <strong>of</strong>800 X 600 pixels (SVGA). The projector shall be portable and weigh no more than 10 pounds. It shall include a zoom lens andcomputer and video input ports.Carousel slide projector, approximately 6"H X 14"W X 13"D with auto focus zoom lens, remote control and 10 foot powercord. Convenience outlet required at point <strong>of</strong> use. 22M0430 Recorder / Player, Cassette,VideoM0507 Video TeleconferencingSystem1 VV1 VVPr<strong>of</strong>essional video cassette recorder / player, approximately 5" high X 15" wide X 14" deep with VHS, NTSC, PAL, SECAM,MESECAM video cassette recorder / player capacity; 10 X picture search forward and reverse; long pause mode; digital hourmeter and channel 1 dubbing. Convenience outlet required at point <strong>of</strong> use.Shall be a video conferencing unit consisting <strong>of</strong> a camera, microphone, video/audio compression components, a componentcart and a 32 inch monitor. It shall provide live audio-visual conferencing capabilities to dispersed geographic sites. 22AC: HAS Medical Information Section CMP01 1 AMIE SystemInsert items reuired for project.0Clinic <strong>Management</strong> CRA01 1 Conference RoomDental CRA01 1 Conference RoomA6046 Artwork, Decorative, WithFrameF0690 Workstation, Computer,Enclosed, With Lock1 VV This JSN is to be used for determining and defining location <strong>of</strong> decorative artwork. 21 VVF0835 Stand, Projection 1 VVComputer operator workstation ,approximately 58" high X 36" wide X 25" deep. A fully enclosed workstation for a computer,monitor, printer and supplies. Cabinet has two lockable doors. 2Mobile projection stand with electrical outlet. Equipped with four (4) swivel casters with anti-shimmy spring cups, nonmarkingwheels, two (2) locking, and shelf storage. Convenience outlet required at point <strong>of</strong> use. 2______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 6 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameF2100 Lectern, Mobile, With ReadingLight1 VVF2225 Projector, Overhead 1 VVItem DescriptionPortable floor lectern with reading light and self-contained audio. May use 110V or batteries (not included). Convenienceoutlet required if not using batteries. 2Overhead transparency projector with hi-low lamp switch, thermal safety switch and 15 foot power cord. Convenience outletrequired at point <strong>of</strong> use. 2F3200 Clock, Battery, 12" Diameter 1 VVClock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 2M0385 Projector, Multimedia/Data 1 VVM0415 Projector, Slide, Carousel 1 VVThe projector shall provide computer and video projections. Minimum features included:Brightness <strong>of</strong> not less than 600 ANSI ( American National Standards Institute) Lumens, and a minimum resolution format <strong>of</strong>800 X 600 pixels (SVGA). The projector shall be portable and weigh no more than 10 pounds. It shall include a zoom lens andcomputer and video input ports.Carousel slide projector, approximately 6"H X 14"W X 13"D with auto focus zoom lens, remote control and 10 foot powercord. Convenience outlet required at point <strong>of</strong> use. 22M0430 Recorder / Player, Cassette,VideoM0507 Video TeleconferencingSystem1 VV1 VVPr<strong>of</strong>essional video cassette recorder / player, approximately 5" high X 15" wide X 14" deep with VHS, NTSC, PAL, SECAM,MESECAM video cassette recorder / player capacity; 10 X picture search forward and reverse; long pause mode; digital hourmeter and channel 1 dubbing. Convenience outlet required at point <strong>of</strong> use.Shall be a video conferencing unit consisting <strong>of</strong> a camera, microphone, video/audio compression components, a componentcart and a 32 inch monitor. It shall provide live audio-visual conferencing capabilities to dispersed geographic sites. 22M1801 Computer, Microprocessing,w/Flat Panel Monitor1 VVDesk top microprocessing computer. The unit shall consist <strong>of</strong> a central processing mini tower, flat panel monitor, keyboard,mouse and speakers. The system shall have the following minimum characteristics: a 2.8 GHz Pentium processor; 512 MBmemory; 80GB hard drive; 32/48x CD-ROMDVD combo; a 3.5" floppy drive; 1.44MB network interface card; video 32 MBNVIDIA; a 15 inch flat panel color monitor. The computer is used throughout the facility to input, manipulate and retrieveinformation.2AC: Exam / Treatment Modules (ETM) CRA02 5 Multipurpose Conference / ClassroomA6046 Artwork, Decorative, WithFrameF0835 Stand, Projection 1 VV1 VV This JSN is to be used for determining and defining location <strong>of</strong> decorative artwork. 5Mobile projection stand with electrical outlet. Equipped with four (4) swivel casters with anti-shimmy spring cups, nonmarkingwheels, two (2) locking, and shelf storage. Convenience outlet required at point <strong>of</strong> use. 5F2100 Lectern, Mobile, With ReadingLight1 VVF2225 Projector, Overhead 1 VVPortable floor lectern with reading light and self-contained audio. May use 110V or batteries (not included). Convenienceoutlet required if not using batteries. 5Overhead transparency projector with hi-low lamp switch, thermal safety switch and 15 foot power cord. Convenience outletrequired at point <strong>of</strong> use. 5F3200 Clock, Battery, 12" Diameter 1 VVClock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 5M0385 Projector, Multimedia/Data 1 VVM0415 Projector, Slide, Carousel 1 VVThe projector shall provide computer and video projections. Minimum features included:Brightness <strong>of</strong> not less than 600 ANSI ( American National Standards Institute) Lumens, and a minimum resolution format <strong>of</strong>800 X 600 pixels (SVGA). The projector shall be portable and weigh no more than 10 pounds. It shall include a zoom lens andcomputer and video input ports.Carousel slide projector, approximately 6"H X 14"W X 13"D with auto focus zoom lens, remote control and 10 foot powercord. Convenience outlet required at point <strong>of</strong> use. 55M0430 Recorder / Player, Cassette,VideoM0507 Video TeleconferencingSystem1 VV1 VVPr<strong>of</strong>essional video cassette recorder / player, approximately 5" high X 15" wide X 14" deep with VHS, NTSC, PAL, SECAM,MESECAM video cassette recorder / player capacity; 10 X picture search forward and reverse; long pause mode; digital hourmeter and channel 1 dubbing. Convenience outlet required at point <strong>of</strong> use.Shall be a video conferencing unit consisting <strong>of</strong> a camera, microphone, video/audio compression components, a componentcart and a 32 inch monitor. It shall provide live audio-visual conferencing capabilities to dispersed geographic sites. 55Education Areas CRA03 1 Educational Conference RoomPolice and Security CROP1 1 Holding RoomInsert items required for projecthere.0______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 7 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameItem DescriptionNo Schedule F Items NR 0SPD: Soiled CSDE2 1 Receiving and Decontamination AreaA1195 Counter, Cleanup, With 2 or 3Sinks1 VVA5075 Dispenser, Soap, Disposable 1 VVTwo or three sink cleanup counter. Unit is constructed <strong>of</strong> type 304 corrosion resistant stainless steel. It consists <strong>of</strong> threesinks 14"W X 16"H X 10"D, hot and cold water faucet, and pre-rinse spray hose. Equipped with channel reinforceddrainboards, and backsplash, and supported by tubular stainless steel legs. Unit is designed for use in control sterile supplydecontamination areas.Disposable soap dispenser. One-handed dispensing operation. Designed to accommodate disposable soap cartridge andvalve. 11F3200 Clock, Battery, 12" Diameter 1 VVClock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 1S0940 Washer/Disinfector,STM,1DO,RSCD1WLL,26X24X24 Cham1 VVA recessed mounted (through one wall), single door (vertical sliding with tempered glass window), multi-level, mechanical,washer/disinfector, minimum chamber size 26X24X24, utilizing facility supplied steam. The unit is controlled by amicrocomputer that monitors and controls all unit operations and functions and provides both audible and visual indications <strong>of</strong>deviations. A printer-recorder documents and records each cycle performance. Processing cycles are pre-programmed withpre-wash, wash/cleaning, rinse, and thermal rinse/disinfection. For use in health care facilities and laboratories wherereusable items (instruments, utensils, anesthesia/respiratory goods, and glassware) are handled for decontaminationpurposes. This unit is not a substitute for terminal sterilization. Unit available with manual or power door, various electricalconfigurations, options, and accessories. Price based upon power door, 208V, 3-phase, with various options.1S2635 Cleaner, Ultrasonic, SNGLChamber, CAB, F/S1 VVA free-standing, cabinet mounted, single stainless steel chamber (minimum size 10X24X12), ultrasonic cleaner. The cleaningunit includes the following minimum features: power lid, automatic detergent injector, automatic level controls, automatictimer, and switch fill and drain controls. Sonic cleaning energy provided to the chamber by transducers which are powered bya solid-state generator(s) at a frequency <strong>of</strong> 40 kHz. Designed for use in surgery reprocessing areas, central processingdepartments and laboratories to clean surgical instruments and other hardware with sonic energy.1S2640 Cleaner, Ultrasonic, Console,DBL CHMBR, CAB, F/S1 VVA free-standing, cabinet mounted, double stainless steel chambers (minimum sizes 10X24X12), ultrasonic cleaner and rinserand dryer. The cleaning chamber includes the following minimum features: power lid, automatic detergent injector, automaticlevel controls, automatic timer, and switch fill and drain controls. Sonic cleaning energy provided to the chamber bytransducers which are powered by a solid-state generator(s) at a frequency <strong>of</strong> 40 kHz. The rinse/dryer chamber is <strong>of</strong> thesame basic design, size, and construction as the cleaning chamber. However, the chamber has pre-positioned spray nozzlesto provide complete rinse and purified-water rinse coverage and thermostatically controlled recirculated forced hot air fordrying. Cleaning and rinse/drying chambers are positioned for either right-to-left or left-to-right workflow. Designed for use toclean surgical instruments and other hardware with sonic energy and effectively spray rinse and dry items after soniccleaning.1S9610 Station, Utility / Rack 2 VVRack / utility station. The station consists <strong>of</strong> a stainless steel countertop, 4-1/2" apron, legs and necessary cross-membersupports. The stations are specially designed to handle loading racks or trays for use with a specific manufacturer's relatedequipment and accessories but may also serve a variety <strong>of</strong> general uses, such as an accumulating, sorting, inspecting, orprocessing station. Various station widths/lengths (25" to 126", depending upon manufacturer) are available. Pricing basedon 48' width/length.2SPD: Clean CSIA2 1 Preparation AreaF3200 Clock, Battery, 12" Diameter 1 VVClock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 1M1801 Computer, Microprocessing,w/Flat Panel Monitor1 VVDesk top microprocessing computer. The unit shall consist <strong>of</strong> a central processing mini tower, flat panel monitor, keyboard,mouse and speakers. The system shall have the following minimum characteristics: a 2.8 GHz Pentium processor; 512 MBmemory; 80GB hard drive; 32/48x CD-ROMDVD combo; a 3.5" floppy drive; 1.44MB network interface card; video 32 MBNVIDIA; a 15 inch flat panel color monitor. The computer is used throughout the facility to input, manipulate and retrieveinformation.1______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 8 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameM2700 Sealer, Heat, Plastic Bag,w/Motor, Portable3 VVItem DescriptionPortable plastic bag heat sealing machine. Heavy duty portable sealer, motor driven with foot switch, 16 inches longclamping jaw minimum, 1/8 inch (2mm) wide heat seal, grounding plug and 3-wire electrical cable. Equipped with lowvoltage impulse generator with electronic timer. For making air and water-tight seals on plastic bags. 3S5500 Sterilizer, Hydrogen PeroxideGas, 1.75 cu ft Cham1 VVA floor mounted, low temperature hydrogen peroxide gas plasma sterilizer. Sterilization chamber shall have a capacity <strong>of</strong>approximately 3.5 cubic feet (100 liters). The sterilizer shall be capable <strong>of</strong> processing metal instruments, plastics, heat andmoisture sensitive devices in approximately 75 minutes with no aeration required. Unit shall be equipped with a visualdisplay and audible alarm. A built in printer will provide system performance record for each cycle.1S9610 Station, Utility / Rack 2 VVRack / utility station. The station consists <strong>of</strong> a stainless steel countertop, 4-1/2" apron, legs and necessary cross-membersupports. The stations are specially designed to handle loading racks or trays for use with a specific manufacturer's relatedequipment and accessories but may also serve a variety <strong>of</strong> general uses, such as an accumulating, sorting, inspecting, orprocessing station. Various station widths/lengths (25" to 126", depending upon manufacturer) are available. Pricing basedon 48' width/length.2SPD: Soiled CWSH1 1 Manual Equipment WashDental DNPL1 1 Dental Prosthetic LaboratoryNo Schedule F Items NR 0Insert items required forproject.Dental DNSC2 1 Instrument Preparation and Sterilization RoomA5075 Dispenser, Soap, Disposable 1 VVDisposable soap dispenser. One-handed dispensing operation. Designed to accommodate disposable soap cartridge andvalve. 10D8990 Cleaner, Ultrasonic, 10-12Quart Capacity1 VVUltrasonic cleaner. Used in dental laboratories and operatories to clean dental instruments and tools either as a preliminarystep to sterilization or to remove material. Cleaners are available in several sizes with or without timers and/or heat. Theunits used for the database have a 10-12 quart capacity and are equipped with a timer and heat. 1D9059 Coupler, Quick Disconnect 1 VVQuick disconnect coupler for a low pressure air line on a dental laboratory work bench. The coupler uses a 3/8" NPTconnection to the servicing air supply line. 1F3200 Clock, Battery, 12" Diameter 1 VVClock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 1R6800 Refrigerator/Freezer, 2 Door,10 Cubic FeetS0237 Sterilizer,ELEC,VAC,2DO,RCSD 1WLL, 20x20x38 Cham1 VV1 VVThis is a 10 cubic foot frostless top mount refrigerator/freezer combination that is used in households or other areas wheregeneral purpose storage <strong>of</strong> perishable items is required. 1A recessed mounted (through one wall), double power doors (vertical sliding), vacuum, sterilizer with integral steamgenerator. The unit is controlled by a microcomputer that monitors and controls all unit operations and functions and providesboth audible and visual indications <strong>of</strong> deviations. A printer-recorder documents and records each cycle performance. Forgeneral purpose pre-vacuum or gravity steam sterilization <strong>of</strong> hospital and laboratory supplies at temperatures in the rangefrom 110°C to 135°C (230°F to 275°F). A liquid cycle is also provided at temperatures in the range from 100°C to 121°C(212°F to 250°F). NOTE: Various electrical configurations are available for the integral steam generator, for pricing purposes208V, 50/60HZ, 3PH, 84AMPS is used.1S4800 Sterilizer, SURG INSTRU &Dressing, 10" DIA CHMBR1 VVA self-contained, countertop mounted, electrically heated, steam sterilizer. The unit is controlled by a microcomputer thatmonitors and controls all unit operations and functions and provides visual indication <strong>of</strong> cycle stages and deviations. A printerrecorderdocuments and records each cycle performance. For low volume, convenient, steam sterilization <strong>of</strong> liquids, media,instruments, glassware, and absorbent materials, in clinics and other areas <strong>of</strong> the health care facility.1S0965 Washer/Disinfector, Dental 1 VVWasher disinfector used to clean dental instruments. The unit washes, disinfects and rinses, but does not sterilize theinstruments. 1U0008 Sterlizer, Dry Heat 1 VV Dry Heat Sterlizer for small decon rooms. 1Dental DNTG2 1 Combined Dental Hygiene Operatory______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 9 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionDental DNTR1 1 Recovery RoomItem NameInsert items required forproject.A5075 Dispenser, Soap, Disposable 1 VVItem DescriptionDisposable soap dispenser. One-handed dispensing operation. Designed to accommodate disposable soap cartridge andvalve. 10A5106 Waste Disposal Unit, Sharpsw/Glove DispenserE0222 Worksurface, Computer, O/HCab, Wall Mtd, 48" W1 VV1 VVThe unit is designed for the disposal <strong>of</strong> sharps and complies with OSHA guidelines for the handling <strong>of</strong> sharps. It shall house a5 quart container and be capable <strong>of</strong> being mounted on a wall. It shall have a glove dispenser attached. The unit shall besecured by a locked enclosure.THIS TYPICAL INCLUDES:2 Vertical Hanging Strips1 Lockable Flipper Unit1 Shelf, Storage/Display1 Light1 Tack board1 Cantilevered Work Surface1 Adjustable Keyboard Tray1 CPU Holder11E0906 Locker, Supply, General, WallMtd, 23"W x 20"D1 VVTHIS TYPICAL INCLUDES:1 Locked Storage Container2 Tray/Shelves1 Drawer, 3"H (76mm)3 Drawers, 6"H (152mm)2 Drawers, 9"H (229mm)1 Tray/Shelf DividerDrawer Organizer BinsConsider the need for an E0921 to transport the locker from place to place.1E0954 Cart, Emergency, Mobile, 66"Hx 52"W x 22"D1 VVTHIS TYPICAL INCLUDES:1 Cart body, style-A narrow, w/raised edge top and breakaway lock bar w/tabs2 Accessory rails, side1 Accessory rail, back1 Defibrillator tray; 1 IV pole1 Flip-up shelf1 Wastebasket and holder1 Oxygen1E1500 Rail, MOD, W/MNTD,HX144XDF3200 Clock, Battery, 12" Diameter 1 VV1 F Wall mounted rail used for hanging (mounting) lockers, shelves drawers on a wall.Clock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 11M0750 Flowmeter, Air, Connect w/50PSI Supply1 VVAir flowmeter. Unit has a stainless steel needle valve with clear flowtube for connection to 50 PSI air outlet from centralpipeline system. Requires the appropriate adapter for connection to the wall outlet and fitting to connect to tubing. Databaseprices reflect fittings with an attached DISS power outlet. Other outlet and adapter configurations are available. 1M0755 Flowmeter, Oxygen, Low Flow 1 VVM0765 Regulator, Vacuum 1 VVOxygen flowmeter. Consists <strong>of</strong> a clear crystal flowtube calibrated to 3.5 or 8 LPM depending on manufacturer. For oxygenregulation in hospital settings. Database pricing includes DISS fitting and DISS power outlet and wall adapter. Other fittingand adapter configurations are available.An air/oxygen mixer is designed to accurately control a pressurized gas mixing with an oxygen concentration. Unit containsaudible alarms to warn <strong>of</strong> supply failure, an auxiliary outlet and a oxygen concentration control adjustment range from 21% to100%. The unit can also be used to supply an accurate pre-mixed gas source to respiration or ventilator units. A specificapplication may require an additional air inlet filter/water trap.11______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 10 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameM4116 Monitor, Vital Signs 1 VVItem DescriptionElectronic sphygmomanometer. LCD displays non-invasive blood pressure, pulse rate and temperature. Used in hospitalsand clinics. Includes an optional mobile stand. 1M7660 Defibrillator/Monitor/Recorder,PortableM7845 Monitor, Physiological, Bedside,4 Channel1 VV1 VVPortable defibrillator-monitor-recorder. Integral unit system operable from self-contained rechargeable batteries. ECG maybe viewed through paddles or patient cable. Options include external pacing and 12-Lead. 14 channel bedside physiological monitor. The unit consist <strong>of</strong> a four-channel non-fade monochrome display monitor, an alarmsystem and printer-recording capabilities. The monitor has color coded controls and automatic calibration. The unit displaysup to four waveforms simultaneously. The parameters to be monitored are user selectable. The monitor may be connectedto a central monitoring station. The unit monitors patients in most acute care areas, step-down units, procedure rooms andemergency rooms.1M7905 Oximeter, Pulse 1 VVPulse oximeter for continuous surveillance <strong>of</strong> patient pulse and oxygen saturation rates. Instrument features LED display,audio and visual alarms, automatic calibration and battery operation in case <strong>of</strong> power failure. Other applications include sleepstudies, exercise testing and monitoring certain patients in the home (e.g. infants or patients requiring respiratory therapy). 1Dental DNTS1 1 Oral Surgery RoomDispenser, soap AR VV Dispenser, soap, with foot control, wall mounted over sink (PG-18-1, MCS 10 28 00) #VALUE!D6050 Lights, dental operating 2 VV Lights, dental operating, single ceiling track mounted (to be installed parallel to each other and separated, 12” to 18” (300 mmto 450 mm) apart on both sides <strong>of</strong> mid-line <strong>of</strong> room and with headend <strong>of</strong> tracks, 96” (2400 mm) back from foot wall) 2Utilities junction box template 1 VV Utilities junction box template (according to dental operating unit manufacturer’s design) 1M0750 or M07Flow meter, oxygen 1 VV Flow meter, oxygen 1Cllecting bottle and controls 1 VV Collecting bottle and controls for vacuum outlet 1Utilities junction box 1 VV Utilities junction box, floor surface mounted (mid-line located, 96” (2400 mm) to left <strong>of</strong> right wall and 12” (300 mm) back fromfoot wall) (see Note in Special Equipment Designs Standards section) 1Dental DNXD1 1 X-Ray AreaD3320 Chair, dental 1 VV Chair, dental, operating or surgical chair-table, motor driven 1F3200 Clock, atomic 1 VV Clock, atomic, battery operated 1A5075 Dispenser, Soap, Disposable 1 VVDisposable soap dispenser. One-handed dispensing operation. Designed to accommodate disposable soap cartridge andvalve. 1A5106 Waste Disposal Unit, Sharpsw/Glove Dispenser1 VVD3320 Chair, Operating, Dental 1 VVThe unit is designed for the disposal <strong>of</strong> sharps and complies with OSHA guidelines for the handling <strong>of</strong> sharps. It shall house a5 quart container and be capable <strong>of</strong> being mounted on a wall. It shall have a glove dispenser attached. The unit shall besecured by a locked enclosure.Dental operating chair designed for the treatment and comfort <strong>of</strong> dental patients. The chair shall be capable <strong>of</strong> multiplepositions, shall swivel, contain a adjustable headrest and arm rests that pivot up and down. The chair shall operate bymeans <strong>of</strong> electrohydraulics. The upholstery shall be seamless with no crevices to catch debris and be easy to clean. 11D3565 Resin Curing Unit, Visible Light 1 VVD6050 Light, Dental, Operating,Ceiling, Track1 VVVisible light resin curing unit which provides a high intensity, cold light source <strong>of</strong> visible blue light for the polymerization <strong>of</strong> allvisible light cured materials. The unit provides for time selections between 10 and 60 seconds or continuous operation andbeeps at ten or twenty second intervals during use.Dental operating light used to illuminate the field <strong>of</strong> work. This is a single light unit on a cantilever arm mounted from acolumn which is suspended from a moving trolley in a ceiling track. The light can be used in installations where the ceilingheight is between 8 and 10.5 feet; some units can mount to ceilings as high as 13 feet. Database physical dimensions referto the light's maximum travel dimensions centered on the ceiling mounting track. The database weight includes the light, armand trolley. Mounting this light may require reinforcing the ceiling or hanging the mount from the underside <strong>of</strong> the slab abovea suspended ceiling.11D7090 Utility Center, Dental, Wall orFloor Mounted1 VVUtility center. The unit contains electrical and quick connect air, waste and water utility connections. The centeraccommodates one umbilical and includes shut-<strong>of</strong>f valves and regulators for both the air and water supplies. 1______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 11 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameD8250 Delivery System, DentalOperating1 VVItem DescriptionDental operating unit. The dentist and/or dental hygienist uses the unit for treatment <strong>of</strong> dental patients. The unit contains theoperating connections for handpieces, the water spray and the vacuum system. The unit can be wall, chair or cart mounted. 1F3200 Clock, Battery, 12" Diameter 1 VVClock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 1M1801 Computer, Microprocessing,w/Flat Panel Monitor2 VVDesk top microprocessing computer. The unit shall consist <strong>of</strong> a central processing mini tower, flat panel monitor, keyboard,mouse and speakers. The system shall have the following minimum characteristics: a 2.8 GHz Pentium processor; 512 MBmemory; 80GB hard drive; 32/48x CD-ROMDVD combo; a 3.5" floppy drive; 1.44MB network interface card; video 32 MBNVIDIA; a 15 inch flat panel color monitor. The computer is used throughout the facility to input, manipulate and retrieveinformation.2U0003 Cabinet, Dental, Central 1 VV Systems furniture made for dental operatories Console, X-Ray (Shared)1U0004 Cabinet, Dental, Doctor's, 1 VV Systems furniture made for dental operatories General1U0005 Cabinet, Dental Assistant, 1 VV Systems furniture made for dental operatories General1U0006 Cabinet, Dental, Wall, 42 " 2 VV Systems furniture made for dental operatories 21 VVX6600 Radiographic Unit, Dental, WallMounted, 7 mADental radiographic unit. Wall mounted, 7 mA, 70 kVp, 120 VAC, electronic remote exposure control unit. The unit shall haveelectronic timing with automatic reset timing capability and main power correction unit to adjust for line voltage fluctuations.Tube head shall be <strong>of</strong> the oil immersed, shield type with total inherent filtration <strong>of</strong> 1.5 mm AL , with a focal spot <strong>of</strong> 0.6. 1AMMS: Acquistion and Distribution DOCK1 1 Receiving and Shipping DockAC: Orthopedics (Ortho) DR001 2 Dressing Room, PatientEndoscopy DR001 4 Changing Area, PatientPMR: Physical Therapy (PT) DR001 1 Dressing RoomRadiology DR001 7 Dressing RoomSurgery-Minor Surgery DR001 1 Changing Room, PatientAUD: Audiology EXEN1 1 Electrophysiology RoomAUD: Audiology EXEN1 1 Posturography RoomA5075 Dispenser, Soap, Disposable 1 VVNo Schedule F Items 0No Schedule F Items 0Disposable soap dispenser. One-handed dispensing operation. Designed to accommodate disposable soap cartridge andvalve. 2A5106 Waste Disposal Unit, Sharpsw/Glove DispenserE0210 Worksurface, w/Overhead Cab,Wall Mtd, 48" W1 VV1 VVThe unit is designed for the disposal <strong>of</strong> sharps and complies with OSHA guidelines for the handling <strong>of</strong> sharps. It shall house a5 quart container and be capable <strong>of</strong> being mounted on a wall. It shall have a glove dispenser attached. The unit shall besecured by a locked enclosure.THIS TYPICAL INCLUDES:2 Vertical Hanging Strips1 Lockable Flipper Unit1 Shelf, Storage/Display1 Light1 Cantilevered Work Surface22F3200 Clock, Battery, 12" Diameter 1 VVClock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 2M1620 Holder, Chart, Patient, Wall orDoor Mounted1 VVWall or door mounted patient chart holder. Constructed <strong>of</strong> durable plastic or metal. Used for holding patient records. Size asrequired. 2______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 12 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameM1801 Computer, Microprocessing,w/Flat Panel Monitor1 VVItem DescriptionDesk top microprocessing computer. The unit shall consist <strong>of</strong> a central processing mini tower, flat panel monitor, keyboard,mouse and speakers. The system shall have the following minimum characteristics: a 2.8 GHz Pentium processor; 512 MBmemory; 80GB hard drive; 32/48x CD-ROMDVD combo; a 3.5" floppy drive; 1.44MB network interface card; video 32 MBNVIDIA; a 15 inch flat panel color monitor. The computer is used throughout the facility to input, manipulate and retrieveinformation.2U0012 Chair, Rotary, SinusoidalVertical Axis Test1 A computer program controls the rotary chair. This program also measures the motion <strong>of</strong> the chair (input) and thesimultaneous eye movement (output). This equipment is used in the Sinusoidal Vertical Axis Rotational Test. 2AUD: Audiology EXOS1 1 <strong>Office</strong>, Therapy Room, AudiologistAUD: Speech Pathology (SP) EXOS1 1 <strong>Office</strong>, Therapy Room, Speech PathologistAUD: Speech Pathology (SP) EXOS1 1 Speech Analysis LaboratoryA5180 Curtain, cubicle AR VV Curtain, cubicle #VALUE!M1801 Desktop PC 1 VV Desktop PC with keyboard 3A5075 Dispenser, soap 1 VV Dispenser, soap, liquid, wall mounted 3M9050 Table, examining 1 VV Table, examining, padded, adjustable top, approx. 74” x 21” x 30” (1850 mm x 525 mm x 750 mm) 3M4200 Ophthalmoscope 1 VV Ophthalmoscope, wall hung 3M4299 Otoscope 1 VV Otoscope, wall hung 3M4100 Sphygmomanometer 1 VV Sphygmomanometer, wall hung 3X3930 Illuminator, x-ray film AR VV Illuminator, x-ray film, 120 volt, wall mounted, individual switch for two, 14” x 17” (350 mm x 425 mm) radiographs, 31” W x20” H (775 mm W x 500 mm H) #VALUE!F2300 Magazine/ literature rack 1 VV Magazine/ literature rack, wall mounted 3F3200 Clock, atomic 1 VV Clock, atomic, battery operated 3A5106 Sharps container 1 VV Sharps container, wall mounted 3AC: Exam / Treatment Modules (ETM) EXRG3 69 Multipurpose Exam RoomAC: Exam / Treatment Modules (ETM) EXRG3 1 Special Purpose Dermatology Exam RoomMental Health: Mental Health Clinic EXRG3 1 Exam / Treatment RoomA1132 Rail, Accessory Mounting,Length As Required1 VVHorizontal mounting rail will consist <strong>of</strong> lock mounting devices capable <strong>of</strong>; supporting up to 75 pounds each, beingrepositioned, and mounting and dismounting <strong>of</strong> equipment without the use <strong>of</strong> tools. The rail must be capable <strong>of</strong> supportingmedical equipment and accessories normally found in exam or patient rooms. The rail system must be capable <strong>of</strong> mountingand dismounting equipment without leaving or creating new holes in the finished surface <strong>of</strong> the wall.71A5075 Dispenser, Soap, Disposable 1 VVDisposable soap dispenser. One-handed dispensing operation. Designed to accommodate disposable soap cartridge andvalve. 71A5106 Waste Disposal Unit, Sharpsw/Glove DispenserA6046 Artwork, Decorative, WithFrameE0222 Worksurface, Computer, O/HCab, Wall Mtd, 48" W1 VVThe unit is designed for the disposal <strong>of</strong> sharps and complies with OSHA guidelines for the handling <strong>of</strong> sharps. It shall house a5 quart container and be capable <strong>of</strong> being mounted on a wall. It shall have a glove dispenser attached. The unit shall besecured by a locked enclosure.1 VV This JSN is to be used for determining and defining location <strong>of</strong> decorative artwork. 711 VVTHIS TYPICAL INCLUDES:2 Vertical Hanging Strips1 Lockable Flipper Unit1 Shelf, Storage/Display1 Light1 Tack board1 Cantilevered Work Surface1 Adjustable Keyboard Tray1 CPU Holder7171F3200 Clock, Battery, 12" Diameter 1 VVClock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 71______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 13 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameM1801 Computer, Microprocessing,w/Flat Panel Monitor1 VVItem DescriptionDesk top microprocessing computer. The unit shall consist <strong>of</strong> a central processing mini tower, flat panel monitor, keyboard,mouse and speakers. The system shall have the following minimum characteristics: a 2.8 GHz Pentium processor; 512 MBmemory; 80GB hard drive; 32/48x CD-ROMDVD combo; a 3.5" floppy drive; 1.44MB network interface card; video 32 MBNVIDIA; a 15 inch flat panel color monitor. The computer is used throughout the facility to input, manipulate and retrieveinformation.71M4100 Sphygmomanometer, Aneroid,Wall MountedM4200 Otoscope/Ophthalmoscope,Wall Mounted1 VV1 VVAneroid sphygmomanometer. Unit is wall mounted and has large graphic dial display for easy reading from all angles. It hasa 90 degree (angle) swivel and 10 degree (angle) forward tilt to reduce glare. Unit accuracy is within 1% <strong>of</strong> reading. Sturdyimpact-resistant construction.Wall mounted otoscope and ophthalmoscope. Includes 6 foot line cord and plug and accepts and includes two handles.Contains head turn-on/turn-<strong>of</strong>f, built-in speculum tray and 8 foot coiled cords. Unit is designed for use in patient exam rooms. 7171M7400 Light, Exam, Table Mounted,Spotlight1 VVThe exam light shall be table mounted. The light will be a halogen bulb that can produce a continuous and homogeneousspot <strong>of</strong> light adjustable from 5 to 9 inches in diameter from a set distance. The light intensity shall be a minimum <strong>of</strong> 750 footcandlesat a distance <strong>of</strong> 16 inches and have a color temperature <strong>of</strong> 3,200 degrees Kelvin. The unit will consist <strong>of</strong> an arm orsleeve <strong>of</strong> approximately 45 inches in length to allow for easy arm rotation and arm movement up and down.71M9025 Table, Examination/Treatment,With Cabinet1 VVTable, examination/treatment with cabinet. Cabinet type exam table with three section upholstered top adjustable to a fullchair position. Concealed heel stirrups, dual outlets, drawers, and storage space with optional armboard. Unit is designed forgeneral use examination/treatment rooms.71X3830 Illuminator, Film, Single, WallMountedAC: Exam / Treatment Modules (ETM) EXRG4 5 NS: Nurse Triage RoomA1132 Rail, Accessory Mounting,Length As Required1 VV1 VVSingle film illuminator approximately 20"H x 17"W x 5"D. This is a single panel wall mounted unit. Characteristics andcomponents include, two 15 watt fluorescent tubes; gravity grip film holder, constructed <strong>of</strong> corrosion resistant galvanized steelwith stainless steel trim, and a clean uncluttered appearance. This unit is used to view X-ray film in hospitals and doctors<strong>of</strong>fices.Horizontal mounting rail will consist <strong>of</strong> lock mounting devices capable <strong>of</strong>; supporting up to 75 pounds each, beingrepositioned, and mounting and dismounting <strong>of</strong> equipment without the use <strong>of</strong> tools. The rail must be capable <strong>of</strong> supportingmedical equipment and accessories normally found in exam or patient rooms. The rail system must be capable <strong>of</strong> mountingand dismounting equipment without leaving or creating new holes in the finished surface <strong>of</strong> the wall.715A5075 Dispenser, Soap, Disposable 1 VVDisposable soap dispenser. One-handed dispensing operation. Designed to accommodate disposable soap cartridge andvalve. 5A5106 Waste Disposal Unit, Sharpsw/Glove DispenserE0222 Worksurface, Computer, O/HCab, Wall Mtd, 48" W1 VV1 VVThe unit is designed for the disposal <strong>of</strong> sharps and complies with OSHA guidelines for the handling <strong>of</strong> sharps. It shall house a5 quart container and be capable <strong>of</strong> being mounted on a wall. It shall have a glove dispenser attached. The unit shall besecured by a locked enclosure.THIS TYPICAL INCLUDES:2 Vertical Hanging Strips1 Lockable Flipper Unit1 Shelf, Storage/Display1 Light1 Tack board1 Cantilevered Work Surface1 Adjustable Keyboard Tray1 CPU Holder55F3200 Clock, Battery, 12" Diameter 1 VVClock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 5M1801 Computer, Microprocessing,w/Flat Panel Monitor1 VVDesk top microprocessing computer. The unit shall consist <strong>of</strong> a central processing mini tower, flat panel monitor, keyboard,mouse and speakers. The system shall have the following minimum characteristics: a 2.8 GHz Pentium processor; 512 MBmemory; 80GB hard drive; 32/48x CD-ROMDVD combo; a 3.5" floppy drive; 1.44MB network interface card; video 32 MBNVIDIA; a 15 inch flat panel color monitor. The computer is used throughout the facility to input, manipulate and retrieveinformation.5______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 14 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameM4116 Monitor, Vital Signs 1 VVItem DescriptionElectronic sphygmomanometer. LCD displays non-invasive blood pressure, pulse rate and temperature. Used in hospitalsand clinics. Includes an optional mobile stand. 5AC: Womens's Health / GYN EXRG8 1 Exam RoomX3930 Illuminator, x-ray film AR VVIlluminator, x-ray film, 120 volts, wall mounted, individual switch for two, 14” x 17” (350 mm x 425 mm) radiographs, 31” W x20” H (775 mm W x 500 mm H) (PG-18-1, MCS 26 51 00) #VALUE!F3200 Clock, atomic 1 VV Clock, atomic, battery operated 1M1801 Desktop PC 1 VV Desktop PC with keyboard 1A5075 Dispenser, soap 1 VV Dispenser, soap, liquid, wall mounted 1M7401 Light, examining portable 1 VV Light, examining, portable, 120 volts, approx. 18” diameter x 75” H (450 mm diameter x 1875 mm H) 1M4200 Otoscope/ ophthalmoscope 1 VV Otoscope/ophthalmoscope, wall hung 1F2300 Magazine/ literature rack 1 VV Magazine/literature rack, wall mounted 1M4100 Sphygmomanometer 1 VV Sphygmomanometer, wall hung 1M9066 Table, examining 1 VV tale, examining and treatment, motorized 1A5106 Sharps container 1 VV Sharps container 1A5106 Glove dispenser 1 VV Glove dispenser 1AUD: Audiology EXVE1 1 Vestibulography RoomA1132 Rail, Accessory Mounting,Length As Required1 VVHorizontal mounting rail will consist <strong>of</strong> lock mounting devices capable <strong>of</strong>; supporting up to 75 pounds each, beingrepositioned, and mounting and dismounting <strong>of</strong> equipment without the use <strong>of</strong> tools. The rail must be capable <strong>of</strong> supportingmedical equipment and accessories normally found in exam or patient rooms. The rail system must be capable <strong>of</strong> mountingand dismounting equipment without leaving or creating new holes in the finished surface <strong>of</strong> the wall.1A5075 Dispenser, Soap, Disposable 1 VVDisposable soap dispenser. One-handed dispensing operation. Designed to accommodate disposable soap cartridge andvalve. 1A5106 Waste Disposal Unit, Sharpsw/Glove DispenserE0210 Worksurface, w/Overhead Cab,Wall Mtd, 48" W1 VV1 VVThe unit is designed for the disposal <strong>of</strong> sharps and complies with OSHA guidelines for the handling <strong>of</strong> sharps. It shall house a5 quart container and be capable <strong>of</strong> being mounted on a wall. It shall have a glove dispenser attached. The unit shall besecured by a locked enclosure.THIS TYPICAL INCLUDES:2 Vertical Hanging Strips1 Lockable Flipper Unit1 Shelf, Storage/Display1 Light1 Cantilevered Work Surface11F3200 Clock, Battery, 12" Diameter 1 VVClock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 1M1620 Holder, Chart, Patient, Wall orDoor MountedM1801 Computer, Microprocessing,w/Flat Panel Monitor1 VV1 VVWall or door mounted patient chart holder. Constructed <strong>of</strong> durable plastic or metal. Used for holding patient records. Size asrequired. 1Desk top microprocessing computer. The unit shall consist <strong>of</strong> a central processing mini tower, flat panel monitor, keyboard,mouse and speakers. The system shall have the following minimum characteristics: a 2.8 GHz Pentium processor; 512 MBmemory; 80GB hard drive; 32/48x CD-ROMDVD combo; a 3.5" floppy drive; 1.44MB network interface card; video 32 MBNVIDIA; a 15 inch flat panel color monitor. The computer is used throughout the facility to input, manipulate and retrieveinformation.1M4200 Otoscope/Ophthalmoscope,Wall Mounted1 VVWall mounted otoscope and ophthalmoscope. Includes 6 foot line cord and plug and accepts and includes two handles.Contains head turn-on/turn-<strong>of</strong>f, built-in speculum tray and 8 foot coiled cords. Unit is designed for use in patient exam rooms. 1M7400 Light, Exam, Table Mounted,Spotlight1 VVThe exam light shall be table mounted. The light will be a halogen bulb that can produce a continuous and homogeneousspot <strong>of</strong> light adjustable from 5 to 9 inches in diameter from a set distance. The light intensity shall be a minimum <strong>of</strong> 750 footcandlesat a distance <strong>of</strong> 16 inches and have a color temperature <strong>of</strong> 3,200 degrees Kelvin. The unit will consist <strong>of</strong> an arm orsleeve <strong>of</strong> approximately 45 inches in length to allow for easy arm rotation and arm movement up and down.1______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 15 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameM7730 Electronystagmographw/Accessories2 VVItem DescriptionUnit detects the electrical currents from muscular contractions which cause eye movement. For the analysis <strong>of</strong> eye motion asan indicator <strong>of</strong> brain stem dysfunction, multiple sclerosis, adverse drug reaction or other disorders causing irregular eyemovements. The system consists <strong>of</strong> a electrical leads, large color display, recorder, 2 direct channels, auxiliary channeloutputs and an electrode terminal box. The system requires one or more stimulation apparatuses such as an ear irrigator(which generates the plumbing requirements), light bar or rotating drum. System options include several microprocessor andprinter configurations. Electrical requirements and weight are for the complete system. Height, width and depth are for thecontrolling microcomputer only.2M9025 Table, Examination/Treatment,With Cabinet1 VVTable, examination/treatment with cabinet. Cabinet type exam table with three section upholstered top adjustable to a fullchair position. Concealed heel stirrups, dual outlets, drawers, and storage space with optional armboard. Unit is designed forgeneral use examination/treatment rooms.1Eye Clinic EYFD1 1 Fitting and Dispensing RoomA5025 Bench, repair 1 VVBench, repair, 30” W x 96” L with 6” W (750 mm W x 2400 mm L with 150 mm W) tool shelf above, 6” (150 mm) deepdrawers under and knee space (PG-18-1, MCS 12 31 00) 1M5016 Screening center 1 VVScreening center with table incorporating following instruments:• Auto refractor• Auto lensometer• Auto tonometer• Auto biometry and keratometerNote: This item may include an optional equipment stand/pole with one to three arms and the ability to accept a phoropterarm.1Eye Clinic EYVF1 1 Visual Fields RoomEye Clinic EYVS1 1 Photography RoomDislplay, glasses-frame 1 VV Display, glasses-frame, approx. 48” (1200 mm) long 1Cabinet, storage for contact 1 VV Cabinet, storage for contact lenses, 18” x 24” x 72” (450 mm x 600 mm x 1800 mm) 1lensescabinet, wall mounted 2 VV Cabinet, wall mounted, 30” (750 mm) wide 2A5075 Dispenser, soap 1 VV Dispenser, soap, wall mounted 1F3200 Clock, atomic 1 VV Clock, atomic, battery operated 1Visual fields instrument(s) 1 VV Visual fields instrument(s) 1M5700 Lens set, trial 1 VV Lens set, trial, ophathalmic 1F3200 Clock, atomic 1 VV Clock, atomic, battery operated 1A5075 Dispenser, Soap, Disposable 1 VVDisposable soap dispenser. One-handed dispensing operation. Designed to accommodate disposable soap cartridge andvalve. 1A5106 Waste Disposal Unit, Sharpsw/Glove DispenserE0210 Worksurface, w/Overhead Cab,Wall Mtd, 48" W1 VV1 VVThe unit is designed for the disposal <strong>of</strong> sharps and complies with OSHA guidelines for the handling <strong>of</strong> sharps. It shall house a5 quart container and be capable <strong>of</strong> being mounted on a wall. It shall have a glove dispenser attached. The unit shall besecured by a locked enclosure.THIS TYPICAL INCLUDES:2 Vertical Hanging Strips1 Lockable Flipper Unit1 Shelf, Storage/Display1 Light1 Cantilevered Work Surface11E1500 Rail, MOD, W/MNTD,HX144XDF3200 Clock, Battery, 12" Diameter 1 VV1 VV Wall mounted rail used for hanging (mounting) lockers, shelves drawers on a wall. 1Clock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 1______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 16 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameM1620 Holder, Chart, Patient, Wall orDoor MountedM1801 Computer, Microprocessing,w/Flat Panel Monitor1 VV1 VVItem DescriptionWall or door mounted patient chart holder. Constructed <strong>of</strong> durable plastic or metal. Used for holding patient records. Size asrequired. 1Desk top microprocessing computer. The unit shall consist <strong>of</strong> a central processing mini tower, flat panel monitor, keyboard,mouse and speakers. The system shall have the following minimum characteristics: a 2.8 GHz Pentium processor; 512 MBmemory; 80GB hard drive; 32/48x CD-ROMDVD combo; a 3.5" floppy drive; 1.44MB network interface card; video 32 MBNVIDIA; a 15 inch flat panel color monitor. The computer is used throughout the facility to input, manipulate and retrieveinformation.1M5510 Camera, Fundus, Digital 1 VVMental Health: Day Treatment Center FSCD1 1 Social Activities / Dining / MultipurposeA6046 Artwork, Decorative, WithFrameF3200 Clock, Battery, 12" Diameter 1 VVThe digital fundus camera system is designed for use in diagnosing and recording ocular disorders. It shall consist <strong>of</strong> a digitalimager, computer, printer, monitor, chin rest, joy stick and s<strong>of</strong>tware to record, store, edit and print digital images. The systemshall include a system table and an adjustable patient table.AR VV This JSN is to be used for determining and defining location <strong>of</strong> decorative artwork. #VALUE!Clock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 11Canteen Service FSDC1 1 CanteenK1695 Conveyor, Meal Tray Return AR VVF3200 Clock, Battery, 12" Diameter 1 VVFixed conveyor for returning soiled meal trays from the main dining room to the tray processing area for cleaning. Thedatabase pricing is based on 24 feet <strong>of</strong> straight conveyor and 4 corner sections. This conveyor could lead to a secondconveyor for tray processing or directly to a dishwasher with tray processing en route. Multiple power outlets will be requireddepending on the conveyors length.Clock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 1#VALUE!Mental Health: Day Treatment Center FSNP1 1 Social Activities Space / KitchenInsert items required for projecthere.AUD: Audiology HAFR1 1 Hearing Aid Fabrication / Modification RoomA5075 Dispenser, Soap, Disposable 1 VVDisposable soap dispenser. One-handed dispensing operation. Designed to accommodate disposable soap cartridge andvalve. 10A5106 Waste Disposal Unit, Sharpsw/Glove Dispenser1 VVThe unit is designed for the disposal <strong>of</strong> sharps and complies with OSHA guidelines for the handling <strong>of</strong> sharps. It shall house a5 quart container and be capable <strong>of</strong> being mounted on a wall. It shall have a glove dispenser attached. The unit shall besecured by a locked enclosure.1______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 17 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameE0078 Workstation, L-Shapedw/Peninsula, Free Std, 78x721 VVItem DescriptionThis section will provide a whole work station typical to quickly plan work areas in clinical or administrative spaces. There willbe a price decrease if typical work stations are used with vertical hanging strips instead <strong>of</strong> panels. THIS TYPICALINCLUDES:1 solid panel, 85"H (2159mm) x 48"W (1219mm);1 solid panel, 85"H (2159mm) x 30"W (762mm); 2 solid panels, 47"H (1194mm) x 24"W (610mm);2 panel connectors, 2-way corner, 85"H (2159mm);1 panel-to-panel connector; 2 finished end hardware;1 cantilevered work surface, 48"W (1219mm);1 peninsula work surface, 72"W (1829mm);1 lockable flipper unit, 48"w (1219mm);1 lockable flipper unit, 30" W (762 mm);1 shelf, storage/display, 48"W (1219mm);1 shelf, storage/display, 30"W (762 mm);1 light, 48"W (1219mm);1 light, 30"W (762mm);1 tack board, 48"W (1219mm);1 tool rail, 30"W (762mm);1 paper tray;1 diagonal tray; 1 adjustable keyboard tray;1 mobile pedestal, box/file.1E0906 Locker, Supply, General, WallMtd, 23"W x 20"D2 VVTHIS TYPICAL INCLUDES:1 Locked Storage Container2 Tray/Shelves1 Drawer, 3"H (76mm)3 Drawers, 6"H (152mm)2 Drawers, 9"H (229mm)1 Tray/Shelf DividerDrawer Organizer BinsConsider the need for an E0921 to transport the locker from place to place.2E1500 Rail, MOD, W/MNTD,HX144XDF3200 Clock, Battery, 12" Diameter 1 VV1 VV Wall mounted rail used for hanging (mounting) lockers, shelves drawers on a wall. 1Clock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 1M0020 Hearing Aid Analyzer 1 VVM1801 Computer, Microprocessing,w/Flat Panel Monitor1 VVHearing aid analyzer. It includes a complete acoustic test system, comprised <strong>of</strong> a control unit, color monitor, and hearing aidtest box. For use in automatically testing, calculating and printing all electrical and acoustical performance data <strong>of</strong> anyhearing aid in accordance with ANSI S3.22.Desk top microprocessing computer. The unit shall consist <strong>of</strong> a central processing mini tower, flat panel monitor, keyboard,mouse and speakers. The system shall have the following minimum characteristics: a 2.8 GHz Pentium processor; 512 MBmemory; 80GB hard drive; 32/48x CD-ROMDVD combo; a 3.5" floppy drive; 1.44MB network interface card; video 32 MBNVIDIA; a 15 inch flat panel color monitor. The computer is used throughout the facility to input, manipulate and retrieveinformation.11M4915 Chair, Exam/Treatment, ENT,w/Adjustable Light1 VVENT exam/treatment chair with adjustable light. Chair can be rotated 330 degrees locking at desired position. Unit iselectrically powered for precise positioning and has an adjustable headrest and armrest. It may include an adjustablegooseneck light. Unit is designed for use during examinations, treatments, and minor procedures. 1Endoscopy JANC1 1 Housekeeping Aides Closet (HAC)EMS JANC1 7 Housekeeping Aids Closet (HAC)______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 18 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NamePharmacy: Secure Areas JANC1 1 Oncology: Housekeeping Aids Closet HACRadiology JANC1 1 Housekeeping Aides Closet - HACSPD: Clean JANC1 1 Housekeeping Aides Closet (HAC)SPD: Soiled JANC1 1 Housekeeping Aides Closet (HAC)Surgery-Ambulatory Surgery JANC1 1 Cystoscopy: Housekeeping Aides Closet (HAC)Surgery-Ambulatory Surgery JANC1 1 OR: Housekeeping Aides Closet 1 (HAC), SmallSurgery-Ambulatory Surgery JANC1 1 OR: Housekeeping Aides Closet 2 (HAC), LargeSurgery-Minor Surgery JANC1 1 Housekeeping Aides ClosetA5075 Dispenser, Soap, Disposable 1 VVItem DescriptionDisposable soap dispenser. One-handed dispensing operation. Designed to accommodate disposable soap cartridge andvalve. 16Surgery-Ambulatory Surgery LBBP1 1 OR: Laboratory, Frozen SectionInsert items required for projecthere.AC: Dermatology (Derm) LBDE1 1 Dermatology LaboratoryA5075 Dispenser, Soap, Disposable 1 VVDisposable soap dispenser. One-handed dispensing operation. Designed to accommodate disposable soap cartridge andvalve. 10A5106 Waste Disposal Unit, Sharpsw/Glove Dispenser1 VVF3200 Clock, Battery, 12" Diameter 1 VVThe unit is designed for the disposal <strong>of</strong> sharps and complies with OSHA guidelines for the handling <strong>of</strong> sharps. It shall house a5 quart container and be capable <strong>of</strong> being mounted on a wall. It shall have a glove dispenser attached. The unit shall besecured by a locked enclosure.Clock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 11L0100 Microscope, Binocular 1 VVBinocular microscope. Equipped with plan achromatic objectives to suit work in brightfield, phase contrast, darkfield,photomicrography, dual viewing and projection screen. Microscope has a high light intensity, 100 watt halogen lamp, forconstant color temperature and illumination, a three step variable transformer, focusable aspheric abbe condenser system;heat absorbing glass; centerable field diaphragm; two built-in filter turrets permitting a combination <strong>of</strong> selective light balancingand color compensating filters. Other components/features include a swing-in condenser, 4X objective, quadruple nosepiece,10X wide field eyepieces and a graduated stage. Other observation tubes can be added. It is used in laboratories for cellcounting and other observation techniques.1M1801 Computer, Microprocessing,w/Flat Panel Monitor1 VVDesk top microprocessing computer. The unit shall consist <strong>of</strong> a central processing mini tower, flat panel monitor, keyboard,mouse and speakers. The system shall have the following minimum characteristics: a 2.8 GHz Pentium processor; 512 MBmemory; 80GB hard drive; 32/48x CD-ROMDVD combo; a 3.5" floppy drive; 1.44MB network interface card; video 32 MBNVIDIA; a 15 inch flat panel color monitor. The computer is used throughout the facility to input, manipulate and retrieveinformation.1M1825 Printer, Computer 1 VVR7000 Refrigerator, 14 Cubic Feet 1 VVHigh resolution computer printer with a variety <strong>of</strong> type styles and sheet/envelope feeder trays. Database information reflectsnetwork ready, medium duty <strong>of</strong>fice style laser printers. Other types <strong>of</strong> printers (bubble jet, dot matrix, line or plotter) as wellas light or heavy use capabilities are available.This is a 14 Cubic Foot frostless top mount refrigerator/freezer approximately 64" H x 28" W x 29" D. Combination unit that isused in households or other areas where general purpose storage <strong>of</strong> perishable items is required. 11PLM: Laboratories LBSM1 1 Sterilization and Solution Preparation RoomInsert items required for projecthere.AC: Oncology (ONC) LBVP1 1 Oncology LabPLM: Laboratories LBVP1 1 Blood Specimen Collection RoomA5075 Dispenser, Soap, Disposable 1 VVDisposable soap dispenser. One-handed dispensing operation. Designed to accommodate disposable soap cartridge andvalve. 20______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 19 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameA5106 Waste Disposal Unit, Sharpsw/Glove Dispenser1 VVF3200 Clock, Battery, 12" Diameter 1 VVItem DescriptionThe unit is designed for the disposal <strong>of</strong> sharps and complies with OSHA guidelines for the handling <strong>of</strong> sharps. It shall house a5 quart container and be capable <strong>of</strong> being mounted on a wall. It shall have a glove dispenser attached. The unit shall besecured by a locked enclosure.Clock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 22L0090 Table, Microscope, 1-2 Person 1 VVL0100 Microscope, Binocular 1 VVMicroscope table for one to two viewers. The table has no casters, secured adjustable work positions and adjustablepedestal legs. Work top is 1" thick and pressure resistant. Different size options are available. Used as a single or dualteaching microscope table.Binocular microscope. Equipped with plan achromatic objectives to suit work in brightfield, phase contrast, darkfield,photomicrography, dual viewing and projection screen. Microscope has a high light intensity, 100 watt halogen lamp, forconstant color temperature and illumination, a three step variable transformer, focusable aspheric abbe condenser system;heat absorbing glass; centerable field diaphragm; two built-in filter turrets permitting a combination <strong>of</strong> selective light balancingand color compensating filters. Other components/features include a swing-in condenser, 4X objective, quadruple nosepiece,10X wide field eyepieces and a graduated stage. Other observation tubes can be added. It is used in laboratories for cellcounting and other observation techniques.22L1350 Centrifuge, Table, Small, 3200RPM, 6 PlaceAR VVSmall table centrifuge. Characteristics/components include a speed range up to 3200 RPM, steel guard bowl, electric motor,speed controlled by a dial rheostat, a six place trunnion head to accommodate 15 ml tubes contained in metal shields withrubber cushions, numbered tube slots and a safety cap. Used in a laboratory for general purpose centrifugation <strong>of</strong> samples. #VALUE!R6080 Refrigerator/Freezer, Biological,SS, 2 DoorAR VVBiological refrigerator/freezer. This unit has double doors, stainless steel exterior and shelves. It is used in laboratories andhospital pharmacies for cold storage and general use. Size and capacity is dependent on site requirements. #VALUE!Dental LCCL1 1 Linen Room and Clean SPD CartEMS LCCL1 1 Storage, Clean Linen CartNo Schedule F Items AR NR 0Dental LCSL1 1 Soiled SPD Cart HoldingEMS LCSL1 1 Storage, Soiled Linen CartNo Schedule F Items AR NR 0AC: Patient Education (Pat EDU) LIBV1 1 Information Resource CenterInsert items required for projecthere.PLM: Laboratories LMCH1 1 Clinical ChemistryPLM: Laboratories LMM03 1 Clinical MicrobiologyInsert items required for projecthere.L2336 Cabinet, air flow 1 VVCabinet, air flow, biological, with lab air, fuel gas and lab vacuum outlets, 120 volt, receptacle (PG-18-1, PG-18-6, MCS 11 5353) 100Lobby LOB01 1 Public TelephonesR7250 Refrigerator/Freezer 1 VV Refrigerator/freezer, 120 volt, domestic, approx. 31” W x 28” D 66” H (775 mm W x 700 mm D x 1650 mm H) 1A5075 Dispenser, soap 1 VV Dispenser, soap, liquid, wall mounted 1L0100 Microscope 1 VV microscope 1L4215 Incubator, bench top 1 VV Incubator, bench top 1A6046 Artwork, Decorative, WithFrame1 VV This JSN is to be used for determining and defining location <strong>of</strong> decorative artwork. 1F2420 Lamp, Table, With Shade 1 VV Table lamp, 27-34" high X 6" wide X 6" deep with linen shade. Convenience outlet required at point <strong>of</strong> use. 1F3200 Clock, Battery, 12" Diameter 1 VV Clock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 1______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 20 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameDental LR002 1 Locker Room / Changing AreaEMS: LLTS LR002 1 Locker RoomSurgery-Ambulatory Surgery LR002 1 Changing Room, PatientSurgery-Ambulatory Surgery LR002 1 OR: Locker Room, Female StaffSurgery-Ambulatory Surgery LR002 1 OR: Locker Room, Male StaffSurgery-Minor Surgery LR002 1 Locker Room, Female StaffSurgery-Minor Surgery LR002 1 Locker Room, Male StaffA1040 Locker, 2 Person, Side by Side,72x15x18AR VVItem DescriptionTwo person locker, double tier, 72Hx12Wx18D. This unit includes hooks for coats and hats. Door equipped with safety guardhandles. Designed for storage <strong>of</strong> coats, hats, and other personal belongings. Other width and depths are available. #VALUE!A5025 Bench, Locker Room, Portable AR VVPortable locker room bench. Approximately 1-1/2" thick. Benches shall be laminated hardwood with a moisture resistantsealer or anodized aluminum Units are mounted on strong pedestals. #VALUE!Dental MECH1 1 Mechanical Room-OR-A5020 Bench, Locker Room, FloorMountedAR VV'Locker room bench. Floor mounting -1-1/4" thick. Benches are sanded smooth with two coats <strong>of</strong> moisture-resistant sealer toensure a protective, satin gloss surface, and mounted on strong steel pedestal anchored to the floor. Over all height <strong>of</strong> 18"includes pedestal. Size as required.No Schedule F Items NR 0AC: Exam / Treatment Modules (ETM) MEDP1 2 NS: Medication RoomAC: Dermatology (Derm) MEDP1 1 Dermatology Medication Prep / Storage RoomMental Health: Methadone MaintenanceMEDP1 1 Medication / Treatment RoomSurgery-Ambulatory Surgery MEDP1 1 Postanesthesia Recovery (PAR): Medication Preparation RoomA5075 Dispenser, soap 1 VV Dispenser, soap, liquid, wall mounted 5A5085 Dispenser, paper cup 1 VV Dispenser, paper cup, wall mounted 5M3150 Automated storage/ dispensing AR VV Automated storage/dispensing unit (cell) secure, approx. 27” W x 25” D x 78” H (675 mm W x 635 mm D x 1950 mm H) unit#VALUE!A5106 Sharps container 1 VV Sharps container 5M7250 Cart, medication 1 VV Cart, medication, with PC computer system 36” x 30” x 36” (900 mm x 750 mm x 900 mm) 5AMMS: Acquistion and Distribution MMCR2 1 Holding Area, Unposted StockNo Schedule F Items NR 0AMMS: Acquistion and Distribution MMGS1 1 Storage, Medical and GeneralNo Schedule F Items NR 0AMMS: Acquistion and Distribution MMRP1 1 Receiving and Issue Area#VALUE!______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 21 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameE0078 Workstation, L-Shapedw/Peninsula, Free Std, 78x721 VVItem DescriptionThis section will provide a whole work station typical to quickly plan work areas in clinical or administrative spaces. There willbe a price decrease if typical work stations are used with vertical hanging strips instead <strong>of</strong> panels. THIS TYPICALINCLUDES:1 solid panel, 85"H (2159mm) x 48"W (1219mm);1 solid panel, 85"H (2159mm) x 30"W (762mm); 2 solid panels, 47"H (1194mm) x 24"W (610mm);2 panel connectors, 2-way corner, 85"H (2159mm);1 panel-to-panel connector; 2 finished end hardware;1 cantilevered work surface, 48"W (1219mm);1 peninsula work surface, 72"W (1829mm);1 lockable flipper unit, 48"w (1219mm);1 lockable flipper unit, 30" W (762 mm);1 shelf, storage/display, 48"W (1219mm);1 shelf, storage/display, 30"W (762 mm);1 light, 48"W (1219mm);1 light, 30"W (762mm);1 tack board, 48"W (1219mm);1 tool rail, 30"W (762mm);1 paper tray;1 diagonal tray; 1 adjustable keyboard tray;1 mobile pedestal, box/file.1F2700 Reader, Bar Code, Hand Held,With InterfaceM1801 Computer, Microprocessing,w/Flat Panel Monitor1 VV1 VVHand held laser bar code reader with computer interface. Used for automated inventory, using bar code stickers / labels.Convenience outlet required at point <strong>of</strong> use. 1Desk top microprocessing computer. The unit shall consist <strong>of</strong> a central processing mini tower, flat panel monitor, keyboard,mouse and speakers. The system shall have the following minimum characteristics: a 2.8 GHz Pentium processor; 512 MBmemory; 80GB hard drive; 32/48x CD-ROMDVD combo; a 3.5" floppy drive; 1.44MB network interface card; video 32 MBNVIDIA; a 15 inch flat panel color monitor. The computer is used throughout the facility to input, manipulate and retrieveinformation.1M1840 Printer/Copier/Fax Combination 1 VV Multifunctional printer, fax, scanner and copier (PFC) all-in-one machine. 1M2020 Cabinet, Storage, Safety, Built-In, Vented1 VVSafety storage cabinet. This unit is <strong>of</strong> double steel wall construction, with vented grounding attachment, raised leak pro<strong>of</strong>door sill, and adjustable shelving. Equipped with two doors and three-point key lock. The construction meets standards set byOSHA and NFPA Code 30 requirements. Designed for storage <strong>of</strong> flammable type liquids. The cabinet fits into a laboratorycasework configuration and its ventilation ports are in the back to leave the counterspace free. The cabinet requiresventilation ducting and an exhaust fan as part <strong>of</strong> the HVAC (heating, ventilation and air conditioning) system.1M2125 Stacker, Straddle, 127" Lift,2000 lb Capacity1 VVM2130 Truck, Hydraulic Lift, Electric 1 VVStraddle stacker. Battery powered with 2000 pound lifting capacity. Unit lifts to heights up to 127". Equipped with a extraheavy duty hydraulic system. Unit has a built-in automatic battery charger. Electrical requirements are for the charger.Designed for pallet lifting.Electric lift truck. Equipped with heavy duty hydraulic system and 12 V battery. For use within enclosed warehouse spaces.Adjustable 25" (approx) long forks. Complete with 10 amp charger. Counterweight must be used to help prevent tipping.NOTE: Not recommended for moving long distances or over uneven surfaces. 11M7780 Scanner, Document 1 VVScanner for recording printed material in an electronic format. Some models process both color and black-and-white images.Options include automatic paper feeders and transparency adapters. Most models require connection to a microcomputer forindependent operation or use as part <strong>of</strong> a network. Larger models for high use applications which connect directly to anetwork without passing information through a microcomputer are available.1______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 22 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameItem DescriptionAC: HAS File Unit (FU) MRS01 1 Storage, Medical RecordsAC: HAS File Unit (FU) MRS01 1 Storage, Medical Records, Veteran Volunteers and EmployeesEEG MRS01 1 Storage, EEG RecordsNo Schedule F Items. 0Surgery-Ambulatory Surgery NSTA1 1 Nurse StationSurgery-Minor Surgery NSTA1 1 Control and Communication CenterSurgery-Minor Surgery NSTA1 1 Nurse StationF3200 Clock, Battery, 12" Diameter 1 VV Clock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 3M1801 Computer, Microprocessing,w/Flat Panel Monitor1 VVDesk top microprocessing computer. The unit shall consist <strong>of</strong> a central processing mini tower, flat panel monitor, keyboard,mouse and speakers. The system shall have the following minimum characteristics: a 2.8 GHz Pentium processor; 512 MBmemory; 80GB hard drive; 32/48x CD-ROMDVD combo; a 3.5" floppy drive; 1.44MB network interface card; video 32 MBNVIDIA; a 15 inch flat panel color monitor. The computer is used throughout the facility to input, manipulate and retrieveinformation.3M1820 Imprinter, Data Record, Electric 1 VVElectric data record imprinter. The device accepts embossed plastic patient cards in either the 50 column or the 80 columnformat and adjusts automatically for card size and form thickness. Device will provide clear readable impressions with acycle that is less than 1 second in length. Electro-mechanical design provides for a consistent impression that is independent<strong>of</strong> operator knowledge or technique. Unit may include a date/time stamp as an accessory.3M1840 Printer/Copier/Fax Combination 2 VV Multifunctional printer, fax, scanner and copier (PFC) all-in-one machine. 6Endoscopy NSTA4 1 Nurse StationSurgery-Ambulatory Surgery NSTA4 1 OR: Control and Communication CenterSurgery-Ambulatory Surgery NSTA4 1 Postanesthesia Recovery (PAR): Medication Preparation RoomAC: Urgent Care NTSA4 1 Nurse / Communication StationAC: Exam / Treatment Modules (ETM) NTSA4 2 Nurse Station (NS)F3200 Clock, Battery, 12" Diameter 1 VVClock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 6M1801 Computer, Microprocessing,w/Flat Panel MonitorAR WDesk top microprocessing computer. The unit shall consist <strong>of</strong> a central processing mini tower, flat panel monitor, keyboard,mouse and speakers. The system shall have the following minimum characteristics: a 2.8 GHz Pentium processor; 512 MBmemory; 80GB hard drive; 32/48x CD-ROMDVD combo; a 3.5" floppy drive; 1.44MB network interface card; video 32 MBNVIDIA; a 15 inch flat panel color monitor. The computer is used throughout the facility to input, manipulate and retrieveinformation.#VALUE!M1820 Imprinter, Data Record, Electric 1 VVElectric data record imprinter. The device accepts embossed plastic patient cards in either the 50 column or the 80 columnformat and adjusts automatically for card size and form thickness. Device will provide clear readable impressions with acycle that is less than 1 second in length. Electro-mechanical design provides for a consistent impression that is independent<strong>of</strong> operator knowledge or technique. Unit may include a date/time stamp as an accessory.6M1840 Printer/Copier/Fax Combination 2 VV Multifunctional printer, fax, scanner and copier (PFC) all-in-one machine. 12AC: Clinic Based <strong>Home</strong> Care (CBHC) OFA01 1 <strong>Office</strong>, Clerical Support StaffVoluntary Service OFA01 1 <strong>Office</strong>, ChiefAMMS: Acquistion and Distribution OFA01 1 <strong>Office</strong>, StorekeeperA6046 Artwork, Decorative, WithFrameF3200 Clock, Battery, 12" Diameter 1 VV1 VV This JSN is to be used for determining and defining location <strong>of</strong> decorative artwork. 3Clock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 3______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 23 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameM1801 Computer, Microprocessing,w/Flat Panel Monitor1 VVItem DescriptionDesk top microprocessing computer. The unit shall consist <strong>of</strong> a central processing mini tower, flat panel monitor, keyboard,mouse and speakers. The system shall have the following minimum characteristics: a 2.8 GHz Pentium processor; 512 MBmemory; 80GB hard drive; 32/48x CD-ROMDVD combo; a 3.5" floppy drive; 1.44MB network interface card; video 32 MBNVIDIA; a 15 inch flat panel color monitor. The computer is used throughout the facility to input, manipulate and retrieveinformation.3M1825 Printer, Computer 1 VVAMMS: Administration OFA02 1 <strong>Office</strong>, ChiefAMMS: Administration OFA02 1 <strong>Office</strong>, Supervisor, Procurement SectionAMMS: Administration OFA02 1 <strong>Office</strong>, Supervisor, Supply <strong>Management</strong> SectionAC: HAS (MAS) OFA02 1 <strong>Office</strong>, Travel ClerkAC: HAS (MAS) OFA02 1 <strong>Office</strong>, Travel ClerkAC: HAS (MAS) OFA02 1 <strong>Office</strong>, Travel ClerkAC: HAS (MAS) OFA02 1 <strong>Office</strong>, Travel ClerkAC: HAS (MAS) OFA02 1 <strong>Office</strong>, Travel ClerkAC: HAS Medical Information Section OFA02 1 <strong>Office</strong>, Assistant ChiefAC: HAS Medical Information Section OFA02 1 <strong>Office</strong>, Medical RecordsAC: HAS File Unit (FU) OFA02 1 <strong>Office</strong>, SupervisorAC: Urgent Care OFA02 1 <strong>Office</strong>, Head NurseAC: Exam / Treatment Modules (ETM)OFA02 1 <strong>Office</strong>, Health Benefits Advisor/ Patient Services Asst.AC: Exam / Treatment Modules (ETM) OFA02 1 <strong>Office</strong>, Compensation and PensionAC: Exam / Treatment Modules (ETM) OFA02 5 NS: <strong>Office</strong>, Case ManagerAC: Exam / Treatment Modules (ETM) OFA02 15 NS:<strong>Office</strong>, Physician ExtenderAC: Exam/ Treatment Module (ETM) OFA02 5 NS: <strong>Office</strong>, Social WorkerAC: Exam/ Treatment Modules (ETM) OFA02 8 NS: <strong>Office</strong>, Telephone Traige NurseAC: Nutrition (Dietetics) OFA02 3 <strong>Office</strong>, DieticianAC; Oncology (ONC) OFA02 1 <strong>Office</strong>, Data Coordiantion/ Tumor RegistryAC: Clinic Based <strong>Home</strong> Care (CBHC) OFA02 1 <strong>Office</strong>, Clerical Support StaffAC: Clinical Based <strong>Home</strong> Care (CBHC) OFA02 1 <strong>Office</strong>, NurseAC: Clinic Based <strong>Home</strong> Care (CBHC) OFA02 1 <strong>Office</strong>, Social WorkerAC: Geriatric Evaluation Unit (GEU) OFA02 1 <strong>Office</strong>, Clerical Support StaffAC: Geriatric Evaluation Unit (GEU) OFA02 1 <strong>Office</strong>, Social WorkerAUD: Audiology and Speech Pathology OFA02 1 <strong>Office</strong>, Chief <strong>of</strong> ServiceClinic <strong>Management</strong> OFA02 2 <strong>Office</strong>, Clinic <strong>Management</strong> Support StaffClinic <strong>Management</strong> OFA02 2 <strong>Office</strong>, Medical Administrative <strong>Office</strong>r (MAO)Dental OFA02 1 <strong>Office</strong>, Administrative AssistantEEG OFA02 2 <strong>Office</strong>, TechnicianEMS OFA02 1 <strong>Office</strong>, ChiefEye Clinic OFA02 1 <strong>Office</strong>, Blind Rehabilitation (VIST), CounselorLobby OFA02 1 Escort RoomHAS: Fee Services Section OFA02 8 Workstation, ClericalHAS: Fee Services Section OFA02 2 Workstation, SupervisorHAS: Medical Care Cost Revoery (MCCOFA02 4 Workstation, ClericalHAS: Medical Care Cost Revoery (MCCOFA02 2 Workstation, SupervisorHAS: <strong>Office</strong> <strong>of</strong> the Chief OFA02 3 <strong>Office</strong> ,Administrative AssistantHigh resolution computer printer with a variety <strong>of</strong> type styles and sheet/envelope feeder trays. Database information reflectsnetwork ready, medium duty <strong>of</strong>fice style laser printers. Other types <strong>of</strong> printers (bubble jet, dot matrix, line or plotter) as wellas light or heavy use capabilities are available.3______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 24 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameHAS: <strong>Office</strong> <strong>of</strong> the Chief OFA02 2 <strong>Office</strong>, Assistant ChiefMental Health: Administration OFA02 1 <strong>Office</strong>, DirectorMental Health: Substance Abuse Clinic OFA02 1 <strong>Office</strong> Statistical ClerkPLM OFA02 1 <strong>Office</strong>, Chief Medical TechnologistPharmacy: Secure Areas OFA02 1 <strong>Office</strong>, Assistant / Associate ChiefPharmacy: Secure Areas OFA02 1 <strong>Office</strong>, ChiefPharmacy: Secure Areas OFA02 2 <strong>Office</strong>, Drug Receiving: Inventory Control / Stock ManagerPharmacy: Secure Areas OFA02 3 <strong>Office</strong>, Supervisory PharmacistPMR: Occupational Therapy (OT) OFA02 1 Clinic <strong>Office</strong>Prosthetics and Sensory Aids OFA02 1 <strong>Office</strong>, ChiefProsthetics and Sensory Aids OFA02 1 <strong>Office</strong>, Dispensing Prosthetic ClerkProsthetics and Sensory Aids OFA02 1 <strong>Office</strong>, Prosthetic RepresentativeRadiology OFA02 5 <strong>Office</strong>, Pr<strong>of</strong>essional, Non PhysicianService Organizations OFA02 4 <strong>Office</strong>, Service Organization Representative, PTService Organizations OFA02 2 <strong>Office</strong>, Service Organization Representative, FTSurgery-Minor Surgery OFA02 1 <strong>Office</strong>, Head NurseA6046 Artwork, Decorative, WithFrameE0078 Workstation, L-Shapedw/Peninsula, Free Std, 78x72Item Description1 VV This JSN is to be used for determining and defining location <strong>of</strong> decorative artwork. 1141 VVThis section will provide a whole work station typical to quickly plan work areas in clinical or administrative spaces. There willbe a price decrease if typical work stations are used with vertical hanging strips instead <strong>of</strong> panels. THIS TYPICALINCLUDES:1 solid panel, 85"H (2159mm) x 48"W (1219mm);1 solid panel, 85"H (2159mm) x 30"W (762mm);2 solid panels, 47"H (1194mm) x 24"W (610mm);2 panel connectors, 2-way corner, 85"H (2159mm);1 panel-to-panel connector;2 finished end hardware;1 cantilevered work surface, 48"W (1219mm);1 peninsula work surface, 72"W (1829mm);1 lockable flipper unit, 48"w (1219mm);1 lockable flipper unit, 30" W (762 mm);1 shelf, storage/display, 48"W (1219mm);1 shelf, storage/display, 30"W (762 mm);1 light, 48"W (1219mm);1 light, 30"W (762mm);1 tack board, 48"W (1219mm);1 tool rail, 30"W (762mm);1 paper tray;1 diagonal tray;1 adjustable keyboard tray;1 mobile pedestal, box/file.114F3200 Clock, Battery, 12" Diameter 1 VVClock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 114M1801 Computer, Microprocessing,w/Flat Panel Monitor1 VVDesk top microprocessing computer. The unit shall consist <strong>of</strong> a central processing mini tower, flat panel monitor, keyboard,mouse and speakers. The system shall have the following minimum characteristics: a 2.8 GHz Pentium processor; 512 MBmemory; 80GB hard drive; 32/48x CD-ROMDVD combo; a 3.5" floppy drive; 1.44MB network interface card; video 32 MBNVIDIA; a 15 inch flat panel color monitor. The computer is used throughout the facility to input, manipulate and retrieveinformation.114______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 25 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameAMMS: Administration OFA03 1 <strong>Office</strong>, OpenAC: HAS (MAS) OFA03 1 Interview Room / Clerical WorkstationAC: HAS (MAS) OFA03 1 Workstation, ClericalAC: HAS Medical Information Section OFA03 2 <strong>Office</strong>, SupervisorAC: HAS Medical Information Section OFA03 2 Workstation, Medical Record Technician / ClerkAC: HAS Transcription Unit (TU) OFA03 5 <strong>Office</strong>, Supervisory TranscriptionistAC: HAS Transcription Unit (TU) OFA03 1 Transcription System Controller / RecordsAC: HAS Transcription Unit (TU) OFA03 2 Workstation, TranscriptionistAC: Urgent Care OFA03 1 <strong>Office</strong>, PhysicianAC: Exam / Treatment Modules (ETM) OFA03 5 NS: Cubicle, Resident PhysicianAUD: Audiology and Speech Pathology OFA03 1 <strong>Office</strong>, Administrative AssistantEducation Areas OFA03 1 Instruction AreaPharmacy: Non-Secure Areas OFA03 1 Prescription ReceivingPharmacy: Secure Areas OFA03 1 Data Processing SpacePharmacy: Secure Areas OFA03 1 Oncology: Reference AreaRadiology OFA03 1 <strong>Office</strong>, ReceptionSPD: Clean OFA03 1 Dispatch AreaSurgery-Ambulatory Surgery OFA03 4 Administration: <strong>Office</strong>, ClericalSurgery-Ambulatory Surgery OFA03 1 OR: Cubicle, DictationVoluntary Service OFA03 1 <strong>Office</strong>, Clerical SupportVoluntary Service OFA03 3 Organization WorkstationVoluntary Service OFA03 1 Volunteer Sign-in AreaE0099 Workstation, Corner Work Surf,Free Stand, 72x961 VVTHIS TYPICAL INCLUDES:4 Standard Solid Panel2 Panel-to-Panel Connectors1 Panel Connector, 2-Way Corner2 Finished End Hardware1 Cantilevered Corner Work Surface2 Cantilevered Work Surface3 Lockable Flipper Units3 Lights2 Tackboards2 Tool Rails2 Paper Trays1 Diagonal Tray1 Adjustable Keyboard Tray1 Mobile Pedestal, Box/File2 Support PanelsItem Description38M1801 Computer, Microprocessing,w/Flat Panel Monitor1 VVDesk top microprocessing computer. The unit shall consist <strong>of</strong> a central processing mini tower, flat panel monitor, keyboard,mouse and speakers. The system shall have the following minimum characteristics: a 2.8 GHz Pentium processor; 512 MBmemory; 80GB hard drive; 32/48x CD-ROMDVD combo; a 3.5" floppy drive; 1.44MB network interface card; video 32 MBNVIDIA; a 15 inch flat panel color monitor. The computer is used throughout the facility to input, manipulate and retrieveinformation.38Clinic <strong>Management</strong> OFC01 1 <strong>Office</strong>, Chief Administrative <strong>Office</strong>rDental OFC01 1 <strong>Office</strong> ChiefA6046 Artwork, Decorative, WithFrame1 VV This JSN is to be used for determining and defining location <strong>of</strong> decorative artwork. 2______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 26 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameF3200 Clock, Battery, 12" Diameter 1 VVItem DescriptionClock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 2M1801 Computer, Microprocessing,w/Flat Panel Monitor1 VVDesk top microprocessing computer. The unit shall consist <strong>of</strong> a central processing mini tower, flat panel monitor, keyboard,mouse and speakers. The system shall have the following minimum characteristics: a 2.8 GHz Pentium processor; 512 MBmemory; 80GB hard drive; 32/48x CD-ROMDVD combo; a 3.5" floppy drive; 1.44MB network interface card; video 32 MBNVIDIA; a 15 inch flat panel color monitor. The computer is used throughout the facility to input, manipulate and retrieveinformation.2HAS: <strong>Office</strong> <strong>of</strong> the Chief OFC02 1 <strong>Office</strong>, ChiefM1825 Printer, Computer 1 VVA6046 Artwork, Decorative, WithFrameF3200 Clock, Battery, 12" Diameter 1 VVHigh resolution computer printer with a variety <strong>of</strong> type styles and sheet/envelope feeder trays. Database information reflectsnetwork ready, medium duty <strong>of</strong>fice style laser printers. Other types <strong>of</strong> printers (bubble jet, dot matrix, line or plotter) as wellas light or heavy use capabilities are available.1 VV This JSN is to be used for determining and defining location <strong>of</strong> decorative artwork. 1Clock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 12M1801 Computer, Microprocessing,w/Flat Panel Monitor1 VVDesk top microprocessing computer. The unit shall consist <strong>of</strong> a central processing mini tower, flat panel monitor, keyboard,mouse and speakers. The system shall have the following minimum characteristics: a 2.8 GHz Pentium processor; 512 MBmemory; 80GB hard drive; 32/48x CD-ROMDVD combo; a 3.5" floppy drive; 1.44MB network interface card; video 32 MBNVIDIA; a 15 inch flat panel color monitor. The computer is used throughout the facility to input, manipulate and retrieveinformation.1M1825 Printer, Computer 1 VVAC: Exam / Treatment Modules (ETM) OFD03 65 NS: <strong>Office</strong>, Physician / ProviderAC: Clinic Based <strong>Home</strong> Care (CBHC) OFD03 1 <strong>Office</strong>, PhysicianAC: Geriatric Evaluation Unit (GEU) OFD03 1 <strong>Office</strong>, Nurse PractitionerAC: Geriatric Evaluation Unit (GEU) OFD03 1 <strong>Office</strong>, PhysicianDental OFD03 5 <strong>Office</strong>, DentistEye Clinic OFD03 6 <strong>Office</strong>, Eye Care ProviderMental Health: Methadone MaintenanceOFD03 1 <strong>Office</strong> / Exam Room, Nurse PractitionerMental Health: Substance Abuse Clinic OFD03 1 <strong>Office</strong>, Nurse / PharmacistMental Health: Substance Abuse Clinic OFD03 1 <strong>Office</strong>, PhysicianPLM OFD03 1 <strong>Office</strong>, Pathologist and Microscope AreaSurgery-Ambulatory Surgery OFD03 4 Administration: <strong>Office</strong>, Anesthesiologist/ AnesthetistSurgery-Ambulatory Surgery OFD03 4 Administration: <strong>Office</strong>, ResidentSurgery-Ambulatory Surgery OFD03 4 Administration: <strong>Office</strong>, Staff SurgeonSurgery-Ambulatory Surgery OFD03 1 OR: <strong>Office</strong>, Head NurseA6046 Artwork, Decorative, WithFrameHigh resolution computer printer with a variety <strong>of</strong> type styles and sheet/envelope feeder trays. Database information reflectsnetwork ready, medium duty <strong>of</strong>fice style laser printers. Other types <strong>of</strong> printers (bubble jet, dot matrix, line or plotter) as wellas light or heavy use capabilities are available.1 VV This JSN is to be used for determining and defining location <strong>of</strong> decorative artwork. 961______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 27 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameE0063 Workstation, L-Shapedw/Peninsula, Wall Mtd, 72x721 VVTHIS TYPICAL INCLUDES:3 VERTICAL HANGING STRIPS2 LOCKABLE FLIPPER UNITS2 SHELVES, STORAGE/DISPLAY2 LIGHTS1 TACKBOARD2 TOOL RAILS2 PAPER TRAYS1 DIAGONAL TRAY1 CANTILEVERED WORK SURFACE1 PENINSULA WORK SURFACE1 ADJUSTABLE KEYBOARD TRAY1 MOBILE PEDESTAL, BOX/FILE1 PENCIL DRAWER1 CPU HOLDERItem Description96F3200 Clock, Battery, 12" Diameter 1 VVClock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 96M1801 Computer, Microprocessing,w/Flat Panel Monitor1 VV Desk top microprocessing computer. The unit shall consist <strong>of</strong> a central processing mini tower, flat panel monitor, keyboard,mouse and speakers. The system shall have the following minimum characteristics: a 2.8 GHz Pentium processor; 512 MBmemory; 80GB hard drive; 32/48x CD-ROMDVD combo; a 3.5" floppy drive; 1.44MB network interface card; video 32 MBNVIDIA; a 15 inch flat panel color monitor. The computer is used throughout the facility to input, manipulate and retrieveinformation.96M1825 Printer, Computer 1 VVMental Health: Day Treatment Center OFDC1 1 <strong>Office</strong>, ChiefMental Health: Day Treatment Center OFDC1 5 <strong>Office</strong>, Counseling StaffMental Health: Mental Health Clinic OFDC1 1 <strong>Office</strong>, ChiefMental Health: Mental Health Clinic OFDC1 30 <strong>Office</strong>, Counseling StaffMental Health: Substance Abuse Clinic OFDC1 1 <strong>Office</strong>, ChiefMental Health: Substance Abuse Clinic OFDC1 1 <strong>Office</strong>, PsychologistMental Health: Substance Abuse Clinic OFDC1 1 <strong>Office</strong>, Social WorkerMental Health: Substance Abuse Clinic OFDC1 1 Rehabilitation CounselorA1132 Rail, Accessory Mounting,Length As Required1 VVHigh resolution computer printer with a variety <strong>of</strong> type styles and sheet/envelope feeder trays. Database information reflectsnetwork ready, medium duty <strong>of</strong>fice style laser printers. Other types <strong>of</strong> printers (bubble jet, dot matrix, line or plotter) as wellas light or heavy use capabilities are available.Horizontal mounting rail will consist <strong>of</strong> lock mounting devices capable <strong>of</strong>; supporting up to 75 pounds each, beingrepositioned, and mounting and dismounting <strong>of</strong> equipment without the use <strong>of</strong> tools. The rail must be capable <strong>of</strong> supportingmedical equipment and accessories normally found in exam or patient rooms. The rail system must be capable <strong>of</strong> mountingand dismounting equipment without leaving or creating new holes in the finished surface <strong>of</strong> the wall.9641A6046 Artwork, Decorative, WithFrame1 VV This JSN is to be used for determining and defining location <strong>of</strong> decorative artwork. 41______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 28 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameE0063 Workstation, L-Shapedw/Peninsula, Wall Mtd, 72x721 VVF3200 Clock, Battery, 12" Diameter 1 VVTHIS TYPICAL INCLUDES:3 VERTICAL HANGING STRIPS2 LOCKABLE FLIPPER UNITS2 SHELVES, STORAGE/DISPLAY2 LIGHTS1 TACKBOARD2 TOOL RAILS2 PAPER TRAYS1 DIAGONAL TRAY1 CANTILEVERED WORK SURFACE1 PENINSULA WORK SURFACE1 ADJUSTABLE KEYBOARD TRAY1 MOBILE PEDESTAL, BOX/FILE1 PENCIL DRAWERItem Description1 CPU HOLDERClock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 4141M1801 Computer, Microprocessing,w/Flat Panel Monitor1 VVDesk top microprocessing computer. The unit shall consist <strong>of</strong> a central processing mini tower, flat panel monitor, keyboard,mouse and speakers. The system shall have the following minimum characteristics: a 2.8 GHz Pentium processor; 512 MBmemory; 80GB hard drive; 32/48x CD-ROMDVD combo; a 3.5" floppy drive; 1.44MB network interface card; video 32 MBNVIDIA; a 15 inch flat panel color monitor. The computer is used throughout the facility to input, manipulate and retrieveinformation.41Pharmacy: Non-Secure Areas OFDC2 1 Consultation RoomM1825 Printer, Computer 1 VVM1801 Computer, Microprocessing,w/Flat Panel Monitor1 VVHigh resolution computer printer with a variety <strong>of</strong> type styles and sheet/envelope feeder trays. Database information reflectsnetwork ready, medium duty <strong>of</strong>fice style laser printers. Other types <strong>of</strong> printers (bubble jet, dot matrix, line or plotter) as wellas light or heavy use capabilities are available.Desk top microprocessing computer. The unit shall consist <strong>of</strong> a central processing mini tower, flat panel monitor, keyboard,mouse and speakers. The system shall have the following minimum characteristics: a 2.8 GHz Pentium processor; 512 MBmemory; 80GB hard drive; 32/48x CD-ROMDVD combo; a 3.5" floppy drive; 1.44MB network interface card; video 32 MBNVIDIA; a 15 inch flat panel color monitor. The computer is used throughout the facility to input, manipulate and retrieveinformation.411Radiology OFDR1 1 <strong>Office</strong>, Chief RadiologistRadiology OFDR1 3 <strong>Office</strong>, Staff RadiologistA6046 Artwork, Decorative, WithFrameE0063 Workstation, L-Shapedw/Peninsula, Wall Mtd, 72x721 VV This JSN is to be used for determining and defining location <strong>of</strong> decorative artwork. 41 VVTHIS TYPICAL INCLUDES:3 VERTICAL HANGING STRIPS2 LOCKABLE FLIPPER UNITS2 SHELVES, STORAGE/DISPLAY2 LIGHTS1 TACKBOARD2 TOOL RAILS2 PAPER TRAYS1 DIAGONAL TRAY1 CANTILEVERED WORK SURFACE1 PENINSULA WORK SURFACE1 ADJUSTABLE KEYBOARD TRAY1 MOBILE PEDESTAL, BOX/FILE1 PENCIL DRAWER1 CPU HOLDER4______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 29 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameF3200 Clock, Battery, 12" Diameter 1 VVItem DescriptionClock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 4M1801 Computer, Microprocessing,w/Flat Panel Monitor1 VV Desk top microprocessing computer. The unit shall consist <strong>of</strong> a central processing mini tower, flat panel monitor, keyboard,mouse and speakers. The system shall have the following minimum characteristics: a 2.8 GHz Pentium processor; 512 MBmemory; 80GB hard drive; 32/48x CD-ROMDVD combo; a 3.5" floppy drive; 1.44MB network interface card; video 32 MBNVIDIA; a 15 inch flat panel color monitor. The computer is used throughout the facility to input, manipulate and retrieveinformation.4AC: Orthopedics (Ortho) OPCR1 1 Cast RoomM1825 Printer, Computer 1 VVA5075 Dispenser, Soap, Disposable 1 VVHigh resolution computer printer with a variety <strong>of</strong> type styles and sheet/envelope feeder trays. Database information reflectsnetwork ready, medium duty <strong>of</strong>fice style laser printers. Other types <strong>of</strong> printers (bubble jet, dot matrix, line or plotter) as wellas light or heavy use capabilities are available.Disposable soap dispenser. One-handed dispensing operation. Designed to accommodate disposable soap cartridge andvalve. 14A5106 Waste Disposal Unit, Sharpsw/Glove DispenserE0903 Locker, Supply, w/Shelves,Wall Mtd, 23"W x 20"DE0906 Locker, Supply, General, WallMtd, 23"W x 20"D1 VVThe unit is designed for the disposal <strong>of</strong> sharps and complies with OSHA guidelines for the handling <strong>of</strong> sharps. It shall house a5 quart container and be capable <strong>of</strong> being mounted on a wall. It shall have a glove dispenser attached. The unit shall besecured by a locked enclosure.1 VV THIS TYPICAL INCLUDES:1 Supply Locker1 Drawer, 9"H (229mm)4 Tray/ShelvesDrawer Organizers1 VVConsider the need for an E0921 to transport the locker from place to place.THIS TYPICAL INCLUDES:1 Locked Storage Container2 Tray/Shelves1 Drawer, 3"H (76mm)3 Drawers, 6"H (152mm)2 Drawers, 9"H (229mm)1 Tray/Shelf DividerDrawer Organizer BinsConsider the need for an E0921 to transport the locker from place to place.111E0915 Locker, Supply, Medication,Wall Mtd, 23"W x 20"D1 VVTHIS TYPICAL INCLUDES:1 Locked Storage Container2 Tray/Shelves1 Locker Drawer w/Locked Lid, 6"H (152mm)5 Drawers, 3"H (76mm)3 Drawers, 6"H (152mm)2 Tray/Shelves DividerDrawer Organizer BinsConsider the need for an E0921 to transport the locker from place to place.1E0945 Cart, Computer, Mobile, 36"H x32"W x 22"D1 VVTHIS TYPICAL INCLUDES:1 Cart Body, Style-A Narrow, w/Raised Edge Top1 Flip-Up Shelf1 Sharps Container Holder1 Wastebasket and Holder1 Chart Holder2 Drawers, 3"H (76mm)2 Drawers, 6"H (152mm)Drawer Organizer Bins1E1500 Rail, MOD, W/MNTD,HX144XD1 VV Wall mounted rail used for hanging (mounting) lockers, shelves drawers on a wall. 1______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 30 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameF3200 Clock, Battery, 12" Diameter 1 VVItem DescriptionClock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 1M0750 Flowmeter, Air, Connect w/50PSI Supply1 VVAir flowmeter. Unit has a stainless steel needle valve with clear flowtube for connection to 50 PSI air outlet from centralpipeline system. Requires the appropriate adapter for connection to the wall outlet and fitting to connect to tubing. Databaseprices reflect fittings with an attached DISS power outlet. Other outlet and adapter configurations are available. 1M0755 Flowmeter, Oxygen, Low Flow 1 VVM0765 Regulator, Vacuum 1 VVOxygen flowmeter. Consists <strong>of</strong> a clear crystal flowtube calibrated to 3.5 or 8 LPM depending on manufacturer. For oxygenregulation in hospital settings. Database pricing includes DISS fitting and DISS power outlet and wall adapter. Other fittingand adapter configurations are available.An air/oxygen mixer is designed to accurately control a pressurized gas mixing with an oxygen concentration. Unit containsaudible alarms to warn <strong>of</strong> supply failure, an auxiliary outlet and a oxygen concentration control adjustment range from 21% to100%. The unit can also be used to supply an accurate pre-mixed gas source to respiration or ventilator units. A specificapplication may require an additional air inlet filter/water trap.11M1620 Holder, Chart, Patient, Wall orDoor Mounted1 VVM4835 Cutter, Cast, w/Vacuum 1 VVWall or door mounted patient chart holder. Constructed <strong>of</strong> durable plastic or metal. Used for holding patient records. Size asrequired. 1Cast cutter with vacuum. Item has 2 HP motor and is enclosed in wheeled canister. It is equipped with built-in standpipe andhandle, large bag, extractor hose, and 25 foot power cord. Item is designed for orthopedic use. 1M7420 Light, Exam, Mobile 1 VVMobile examination light mounted on a floor stand with casters. Unit features colored corrected light, an air-cooled shade anda balanced floating arm. Unit may also have a center mount detachable and sterilizable control handle. Designed forexamination, treatment, and emergency areas where cool, color-corrected light is needed. 1M9055 Table, Exam, Orthopedic 1 VVOrthopedic exam table. Consists <strong>of</strong> a steel or wood frame with pull out drawers and storage area. Upholstered top sectionadjustable to any angle. Used for orthopedic examinations. 1P7650 Trap, Plaster, Small 1 VVX3930 Illuminator, Film, Double, WallMounted1 VVPlastic or metal bodied plaster trap. The unit has a one piece body which is approximately 12 inches deep. The top has 1.5inch inlet and drain connections. The trap is used in laboratories to capture solids and preclude the clogging <strong>of</strong> drain lines.The installation must allow sufficient clearance above or below the unit (depending on the manufacturer) to remove thebasket for cleaning.X-ray film illuminator approximately 20' H x 29' W x 6'' D. This is a double, wall mounted type unit with a continuous viewingsurface. The tension film grips are adjustable top and bottom with standard grip strip. The unit's balanced-light viewing isassured by the 32W circular fluorescent lamp. It provides 500 feet candles <strong>of</strong> cool operation across the entire 14" X 17"viewing surface. It is available with or without film-activated switch. The unit can be used in hospitals, examining rooms,satellite <strong>of</strong>fice or lab.11X4112 Console, PACS, Remote View,1k X 1k, 2 Monitors1 VVTwo monitor remote viewing station for picture archiving and retrieval (PACS) system. This station is for use by providersinside or outside <strong>of</strong> radiology to review images. Station includes local image storage, image manipulation, and simultaneousdisplay <strong>of</strong> multiple images on two 1024 x 1024 image display CRT's. Images are stored on a resident hard disk and roll <strong>of</strong>fthe disk as more recent images are sent to the station. Provider may request images from the PACS. Unit must beconnected to the PACS by LAN for image and result receipt. This station is for use in areas like radiologist's <strong>of</strong>fices and theE.R. where a more comprehensive system is required. Console must be DICOM compliant. Input may be by keyboard,mouse, trackball or voice activated commands.1AC: Oncology (ONC) OPCT1 1 Chemotherapy Treatment RoomA1132 Rail, Accessory Mounting,Length As Required1 VVHorizontal mounting rail will consist <strong>of</strong> lock mounting devices capable <strong>of</strong>; supporting up to 75 pounds each, beingrepositioned, and mounting and dismounting <strong>of</strong> equipment without the use <strong>of</strong> tools. The rail must be capable <strong>of</strong> supportingmedical equipment and accessories normally found in exam or patient rooms. The rail system must be capable <strong>of</strong> mountingand dismounting equipment without leaving or creating new holes in the finished surface <strong>of</strong> the wall.1A5075 Dispenser, Soap, Disposable 1 VVDisposable soap dispenser. One-handed dispensing operation. Designed to accommodate disposable soap cartridge andvalve. 1______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 31 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameA5106 Waste Disposal Unit, Sharpsw/Glove DispenserE0915 Locker, Supply, Medication,Wall Mtd, 23"W x 20"DAR VV1 VVItem DescriptionThe unit is designed for the disposal <strong>of</strong> sharps and complies with OSHA guidelines for the handling <strong>of</strong> sharps. It shall house a5 quart container and be capable <strong>of</strong> being mounted on a wall. It shall have a glove dispenser attached. The unit shall besecured by a locked enclosure.THIS TYPICAL INCLUDES:1 Locked Storage Container2 Tray/Shelves1 Locker Drawer w/Locked Lid, 6"H (152mm)5 Drawers, 3"H (76mm)3 Drawers, 6"H (152mm)2 Tray/Shelves DividerDrawer Organizer BinsConsider the need for an E0921 to transport the locker from place to place.#VALUE!1E0954 Cart, Emergency, Mobile, 66"Hx 52"W x 22"D1 VVTHIS TYPICAL INCLUDES:1 Cart body, style-A narrow, w/raised edge top and breakaway lock bar w/tabs2 Accessory rails, side1 Accessory rail, back1 Defibrillator tray; 1 IV pole1 Flip-up shelf1 Wastebasket and holder1 Oxygen tank holder1 Cardiac board and hanger1 Electrical box-4 outlet1 Cord wrap4 Drawer, 3"H (76mm)3 Drawer, 6"H (152mm)Drawer organizer bins.1E1500 Rail, MOD, W/MNTD,HX144XDF3200 Clock, Battery, 12" Diameter AR VV1 VV Wall mounted rail used for hanging (mounting) lockers, shelves drawers on a wall. 1Clock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). #VALUE!M0750 Flowmeter, Air, Connect w/50PSI SupplyAR VVAir flowmeter. Unit has a stainless steel needle valve with clear flowtube for connection to 50 PSI air outlet from centralpipeline system. Requires the appropriate adapter for connection to the wall outlet and fitting to connect to tubing. Databaseprices reflect fittings with an attached DISS power outlet. Other outlet and adapter configurations are available. #VALUE!M0755 Flowmeter, Oxygen, Low Flow AR VVM0765 Regulator, Vacuum AR VVOxygen flowmeter. Consists <strong>of</strong> a clear crystal flowtube calibrated to 3.5 or 8 LPM depending on manufacturer. For oxygenregulation in hospital settings. Database pricing includes DISS fitting and DISS power outlet and wall adapter. Other fittingand adapter configurations are available.An air/oxygen mixer is designed to accurately control a pressurized gas mixing with an oxygen concentration. Unit containsaudible alarms to warn <strong>of</strong> supply failure, an auxiliary outlet and a oxygen concentration control adjustment range from 21% to100%. The unit can also be used to supply an accurate pre-mixed gas source to respiration or ventilator units. A specificapplication may require an additional air inlet filter/water trap.#VALUE!#VALUE!M1801 Computer, Microprocessing,w/Flat Panel Monitor1 VVDesk top microprocessing computer. The unit shall consist <strong>of</strong> a central processing mini tower, flat panel monitor, keyboard,mouse and speakers. The system shall have the following minimum characteristics: a 2.8 GHz Pentium processor; 512 MBmemory; 80GB hard drive; 32/48x CD-ROMDVD combo; a 3.5" floppy drive; 1.44MB network interface card; video 32 MBNVIDIA; a 15 inch flat panel color monitor. The computer is used throughout the facility to input, manipulate and retrieveinformation.1M4116 Monitor, Vital Signs AR VVElectronic sphygmomanometer. LCD displays non-invasive blood pressure, pulse rate and temperature. Used in hospitalsand clinics. Includes an optional mobile stand. #VALUE!______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 32 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameM4266 Pump, Volumetric, Infusion,Multiple LineAR VVItem DescriptionVolumetric infusion pump. Pump is self-regulating with automatic sensor and adjustable rate. Equipped with visual andaudible alarms and up to 10 hour capacity battery. For the administration <strong>of</strong> a wide variety <strong>of</strong> therapeutic agents whereprecise control is required. Unit provides individual control to IV lines simultaneously. #VALUE!M7660 Defibrillator/Monitor/Recorder,Portable1 VVM7905 Oximeter, Pulse AR VVPortable defibrillator-monitor-recorder. Integral unit system operable from self-contained rechargeable batteries. ECG maybe viewed through paddles or patient cable. Options include external pacing and 12-Lead. 1Pulse oximeter for continuous surveillance <strong>of</strong> patient pulse and oxygen saturation rates. Instrument features LED display,audio and visual alarms, automatic calibration and battery operation in case <strong>of</strong> power failure. Other applications include sleepstudies, exercise testing and monitoring certain patients in the home (e.g. infants or patients requiring respiratory therapy). #VALUE!AC: Dermatology (Derm) OPDU1 1 Dermatology Phototherapy Treatment RoomF3200 Clock, atomic 1 VV Clock, atomic, battery operated 1E0210 Modular work station with under 1 VV Modular work station with under counter keyboard tray, overhead storage, and wall hanger strips. counter1A5075 Dispenser, soap 1 VV Dispenser, soap, liquid, wall mounted 1M8192 Hand and foot UV light box 1 VV Hand and foot UV light box, on mobile stand, approx. 24” W x 24” D x 30” H (600 mm W x 600 mm D x 750 mm H) 1Cardiology OPEC1 1 ECG Testing CubicleM1801 PC, computer 2 VV PC, computer system, with keyboard 2M7410/ M819Whole body UV light box 1 VV Whole body UV light box, approx. 4” (100 mm) diameter in closed position 1A5180 Curtain AR VV Curtain, cubicle #VALUE!R7000 Refrigerator, domestic type 1 VV Refrigerator, domestic type, 15 cu ft (0.42 m3), approx. 31” x 28” x 66” (775 mm x 700 mm x 1650 mm) 1M3150 Automated supply storage.Dispensing unitAR VVA5075 Dispenser, Soap, Disposable 1 VVAutomated supply storage/dispensing unit (cell), approx. 27” W x 25” D x 78” H (675 mm W x 635 mm D x 1950 mm H) eachcell #VALUE!Disposable soap dispenser. One-handed dispensing operation. Designed to accommodate disposable soap cartridge andvalve. 1A5106 Waste Disposal Unit, Sharpsw/Glove DispenserE0933 Locker, Supply, Shelf &Drawer, Mbl, 29"W x 20"D1 VV1 VVThe unit is designed for the disposal <strong>of</strong> sharps and complies with OSHA guidelines for the handling <strong>of</strong> sharps. It shall house a5 quart container and be capable <strong>of</strong> being mounted on a wall. It shall have a glove dispenser attached. The unit shall besecured by a locked enclosure.THIS TYPICAL INCLUDES:1 Mobile Supply Locker3 Drawers, 6"H (152mm)5 Tray/Shelves5 Tray/Shelf DividersDrawer Organizer Bins11F3200 Clock, Battery, 12" Diameter 1 VVClock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 1M0750 Flowmeter, Air, Connect w/50PSI Supply1 VVAir flowmeter. Unit has a stainless steel needle valve with clear flowtube for connection to 50 PSI air outlet from centralpipeline system. Requires the appropriate adapter for connection to the wall outlet and fitting to connect to tubing. Databaseprices reflect fittings with an attached DISS power outlet. Other outlet and adapter configurations are available. 1M0755 Flowmeter, Oxygen, Low Flow 1 VVM0765 Regulator, Vacuum 1 VVOxygen flowmeter. Consists <strong>of</strong> a clear crystal flowtube calibrated to 3.5 or 8 LPM depending on manufacturer. For oxygenregulation in hospital settings. Database pricing includes DISS fitting and DISS power outlet and wall adapter. Other fittingand adapter configurations are available.An air/oxygen mixer is designed to accurately control a pressurized gas mixing with an oxygen concentration. Unit containsaudible alarms to warn <strong>of</strong> supply failure, an auxiliary outlet and a oxygen concentration control adjustment range from 21% to100%. The unit can also be used to supply an accurate pre-mixed gas source to respiration or ventilator units. A specificapplication may require an additional air inlet filter/water trap.11______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 33 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionEEG OPEE1 2 EEG Exam RoomItem NameM4100 Sphygmomanometer, Aneroid,Wall MountedM7710 Electrocardiograph, 12 Lead,PortableInsert items required for projecthere.EEG OPEE2 1 EEG Instrument and Work RoomInsert items required for projecthere.Cardiology OPHM1 1 Pacemaker / Holter Monitor RoomAUD: Audiology OPMH1 1 Group Therapy RoomAUD: Speech Pathology (SP) OPMH1 1 Group Therapy RoomMental Health: Administration OPMH1 3 Group Therapy RoomF2250 Camera, Portable, CCTV, WithRecorder1 VV1 VVMental Health: Mental Health Clinic OPMH3 1 Bi<strong>of</strong>eedback Control Room / Tech <strong>Office</strong>Mental Health: Mental Health Clinic OPMH3 1 Bi<strong>of</strong>eedback Treatment RoomA5075 Dispenser, Soap, Disposable 1 VVItem DescriptionAneroid sphygmomanometer. Unit is wall mounted and has large graphic dial display for easy reading from all angles. It hasa 90 degree (angle) swivel and 10 degree (angle) forward tilt to reduce glare. Unit accuracy is within 1% <strong>of</strong> reading. Sturdyimpact-resistant construction.Used to detect the electrical signals associated with cardiac activity, diagnose cardiac abnormalities, determine a patientsresponse to drug therapy and reveal trends or changes in heart function. Capable <strong>of</strong> recording two or more leadssimultaneously, recording an entire 12 lead ECG in about 10 seconds. Includes <strong>of</strong> a 3.5 inch, high density, floppy disk drivefor test storage. Portable.1 VV Portable camera/recorder (camcorder) with video-out capacity to accommodate a remote recorder. 6Disposable soap dispenser. One-handed dispensing operation. Designed to accommodate disposable soap cartridge andvalve. 21100A5106 Waste Disposal Unit, Sharpsw/Glove DispenserE0123 Workstation, Straight, FreeStanding, 72" W1 VV1 VVThe unit is designed for the disposal <strong>of</strong> sharps and complies with OSHA guidelines for the handling <strong>of</strong> sharps. It shall house a5 quart container and be capable <strong>of</strong> being mounted on a wall. It shall have a glove dispenser attached. The unit shall besecured by a locked enclosure.'This JSN will provide a whole work station typical to quickly plan work in areas in clinical or administrative spaces. There willbe a price decrease if typical work stations are used with vertical hanging strips instead <strong>of</strong> panels. THIS TYPICALINCLUDES: 4 Standard Solid Panels, 2 Panel Connectors, 2-Way Corner, 1 Panel-to-Panel Connector, 2 Finished EndHardware, 1 Cantilevered, Work Surface, 2 Lockable Flipper Units, 2 Shelf, Storage/Displays, 2 Lights, 1 Tack board, 1Tool Rail, 1 Paper Tray, 1 Diagonal Tray, 1 Adjustable Keyboard Tray, 1 Mobile Pedestal, Box/File22E0906 Locker, Supply, General, WallMtd, 23"W x 20"D1 VVTHIS TYPICAL INCLUDES:1 Locked Storage Container2 Tray/Shelves1 Drawer, 3"H (76mm)3 Drawers, 6"H (152mm)2 Drawers, 9"H (229mm)1 Tray/Shelf DividerDrawer Organizer BinsConsider the need for an E0921 to transport the locker from place to place.2E0912 Locker, Supply, Med Surg, WallMtd1 VVMedical/Surgical Supply locker, Wall Mounted, Approx 23"W x20"D. THIS TYPICAL INCLUDES:1 Locked Storage Container4 Tray/Shelves5 Drawers, 3"H (76mm)2 Drawers, 6"H (152mm)2 Tray/Shelf DividersDrawer Organizer BinsConsider the need for an E0921 to transport the locker from place to place.2______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 34 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameE1500 Rail, MOD, W/MNTD,HX144XDF3200 Clock, Battery, 12" Diameter 1 VVItem Description1 VV Wall mounted rail used for hanging (mounting) lockers, shelves drawers on a wall. 2Clock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 2M1620 Holder, Chart, Patient, Wall orDoor MountedM1801 Computer, Microprocessing,w/Flat Panel Monitor1 VV1 VVWall or door mounted patient chart holder. Constructed <strong>of</strong> durable plastic or metal. Used for holding patient records. Size asrequired. 2Desk top microprocessing computer. The unit shall consist <strong>of</strong> a central processing mini tower, flat panel monitor, keyboard,mouse and speakers. The system shall have the following minimum characteristics: a 2.8 GHz Pentium processor; 512 MBmemory; 80GB hard drive; 32/48x CD-ROMDVD combo; a 3.5" floppy drive; 1.44MB network interface card; video 32 MBNVIDIA; a 15 inch flat panel color monitor. The computer is used throughout the facility to input, manipulate and retrieveinformation.2M4100 Sphygmomanometer, Aneroid,Wall MountedM7710 Electrocardiograph, 12 Lead,Portable1 VV1 VVM7725 Electromyograph 1 VVAneroid sphygmomanometer. Unit is wall mounted and has large graphic dial display for easy reading from all angles. It hasa 90 degree (angle) swivel and 10 degree (angle) forward tilt to reduce glare. Unit accuracy is within 1% <strong>of</strong> reading. Sturdyimpact-resistant construction.Used to detect the electrical signals associated with cardiac activity, diagnose cardiac abnormalities, determine a patientsresponse to drug therapy and reveal trends or changes in heart function. Capable <strong>of</strong> recording two or more leadssimultaneously, recording an entire 12 lead ECG in about 10 seconds. Includes <strong>of</strong> a 3.5 inch, high density, floppy disk drivefor test storage. Portable.Unit consists <strong>of</strong> a microcomputer, leads, electrically isolated amplifiers, stimulators, display and storage capabilities. Thesystem measures muscular electrical activity during contractions which the patient or a stimulator can induce. Specificapplications include nerve conduction studies to detect myelopathies (myelin degradation), neuropathies (nerve compression)or myopathies (muscle disease). Most units also include an evoked potential capability. See related auditory evokedpotential units at JSN M0035 and similar electronystagmographs at JSN M7730.222M8180 Bi<strong>of</strong>eedback Analysis System 1 VVComputer based bi<strong>of</strong>eedback testing and analysis system. Unit accepts electroencephalograph (EEG), electromyograph(EMG), DC potential, goniometry, body temperature and other physiologic measurements for correlation and analysis. Thesystem is primarily used in psychiatry and psychology clinics for rehabilitation treatments and pain management training. 2Police and Security OPMH4 1 Operations RoomA1132 Rail, Accessory Mounting,Length As Required1 VVHorizontal mounting rail will consist <strong>of</strong> lock mounting devices capable <strong>of</strong>; supporting up to 75 pounds each, beingrepositioned, and mounting and dismounting <strong>of</strong> equipment without the use <strong>of</strong> tools. The rail must be capable <strong>of</strong> supportingmedical equipment and accessories normally found in exam or patient rooms. The rail system must be capable <strong>of</strong> mountingand dismounting equipment without leaving or creating new holes in the finished surface <strong>of</strong> the wall.1A5075 Dispenser, Soap, Disposable 1 VVDisposable soap dispenser. One-handed dispensing operation. Designed to accommodate disposable soap cartridge andvalve. 1A5106 Waste Disposal Unit, Sharpsw/Glove DispenserM4100 Sphygmomanometer, Aneroid,Wall MountedM4200 Otoscope/Ophthalmoscope,Wall Mounted1 VV1 VV1 VVThe unit is designed for the disposal <strong>of</strong> sharps and complies with OSHA guidelines for the handling <strong>of</strong> sharps. It shall house a5 quart container and be capable <strong>of</strong> being mounted on a wall. It shall have a glove dispenser attached. The unit shall besecured by a locked enclosure.Aneroid sphygmomanometer. Unit is wall mounted and has large graphic dial display for easy reading from all angles. It hasa 90 degree (angle) swivel and 10 degree (angle) forward tilt to reduce glare. Unit accuracy is within 1% <strong>of</strong> reading. Sturdyimpact-resistant construction.Wall mounted otoscope and ophthalmoscope. Includes 6 foot line cord and plug and accepts and includes two handles.Contains head turn-on/turn-<strong>of</strong>f, built-in speculum tray and 8 foot coiled cords. Unit is designed for use in patient exam rooms. 111M7400 Light, Exam, Table Mounted,Spotlight1 VVThe exam light shall be table mounted. The light will be a halogen bulb that can produce a continuous and homogeneousspot <strong>of</strong> light adjustable from 5 to 9 inches in diameter from a set distance. The light intensity shall be a minimum <strong>of</strong> 750 footcandlesat a distance <strong>of</strong> 16 inches and have a color temperature <strong>of</strong> 3,200 degrees Kelvin. The unit will consist <strong>of</strong> an arm orsleeve <strong>of</strong> approximately 45 inches in length to allow for easy arm rotation and arm movement up and down.1______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 35 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameM9025 Table, Examination/Treatment,With Cabinet1 VVItem DescriptionTable, examination/treatment with cabinet. Cabinet type exam table with three section upholstered top adjustable to a fullchair position. Concealed heel stirrups, dual outlets, drawers, and storage space with optional armboard. Unit is designed forgeneral use examination/treatment rooms.1Cardiology OPPE1 1 Echocardiography Exam RoomA5075 Dispenser, Soap, Disposable 1 VVDisposable soap dispenser. One-handed dispensing operation. Designed to accommodate disposable soap cartridge andvalve. 1A5106 Waste Disposal Unit, Sharpsw/Glove DispenserE0210 Worksurface, w/Overhead Cab,Wall Mtd, 48" W1 VV1 VVThe unit is designed for the disposal <strong>of</strong> sharps and complies with OSHA guidelines for the handling <strong>of</strong> sharps. It shall house a5 quart container and be capable <strong>of</strong> being mounted on a wall. It shall have a glove dispenser attached. The unit shall besecured by a locked enclosure.THIS TYPICAL INCLUDES:2 Vertical Hanging Strips1 Lockable Flipper Unit1 Shelf, Storage/Display1 Light1 Cantilevered Work Surface11E0912 Locker, Supply, Med Surg, WallMtd1 VVMedical/Surgical Supply locker, Wall Mounted, Approx 23"W x20"D. THIS TYPICAL INCLUDES:1 Locked Storage Container4 Tray/Shelves5 Drawers, 3"H (76mm)2 Drawers, 6"H (152mm)2 Tray/Shelf DividersDrawer Organizer BinsConsider the need for an E0921 to transport the locker from place to place.1E1500 Rail, MOD, W/MNTD,HX144XDF3200 Clock, Battery, 12" Diameter 1 VV1 VV Wall mounted rail used for hanging (mounting) lockers, shelves drawers on a wall. 1Clock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 1M0750 Flowmeter, Air, Connect w/50PSI Supply1 VVAir flowmeter. Unit has a stainless steel needle valve with clear flowtube for connection to 50 PSI air outlet from centralpipeline system. Requires the appropriate adapter for connection to the wall outlet and fitting to connect to tubing. Databaseprices reflect fittings with an attached DISS power outlet. Other outlet and adapter configurations are available. 1M0755 Flowmeter, Oxygen, Low Flow 1 VVM0765 Regulator, Vacuum 1 VVOxygen flowmeter. Consists <strong>of</strong> a clear crystal flowtube calibrated to 3.5 or 8 LPM depending on manufacturer. For oxygenregulation in hospital settings. Database pricing includes DISS fitting and DISS power outlet and wall adapter. Other fittingand adapter configurations are available.An air/oxygen mixer is designed to accurately control a pressurized gas mixing with an oxygen concentration. Unit containsaudible alarms to warn <strong>of</strong> supply failure, an auxiliary outlet and a oxygen concentration control adjustment range from 21% to100%. The unit can also be used to supply an accurate pre-mixed gas source to respiration or ventilator units. A specificapplication may require an additional air inlet filter/water trap.11M1620 Holder, Chart, Patient, Wall orDoor MountedM1801 Computer, Microprocessing,w/Flat Panel Monitor1 VV1 VVWall or door mounted patient chart holder. Constructed <strong>of</strong> durable plastic or metal. Used for holding patient records. Size asrequired. 1Desk top microprocessing computer. The unit shall consist <strong>of</strong> a central processing mini tower, flat panel monitor, keyboard,mouse and speakers. The system shall have the following minimum characteristics: a 2.8 GHz Pentium processor; 512 MBmemory; 80GB hard drive; 32/48x CD-ROMDVD combo; a 3.5" floppy drive; 1.44MB network interface card; video 32 MBNVIDIA; a 15 inch flat panel color monitor. The computer is used throughout the facility to input, manipulate and retrieveinformation.1______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 36 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameX2105 Scanner, Ultrasound, Cardiac(Echo)1 VVItem DescriptionHigh definition, diagnostic ultrasound system for Radiology, Cardiology, Vascular, ob-gyn, Perinatology, and Surgical imagingapplications. The unit employs curved, phased and linear array imaging technology. The system supports colorflow, pulse,continuous wave imaging modalities. On board s<strong>of</strong>tware measurement packages available for all imaging applications. Thesystem is DICOM 3.0 compatible, for easy linkage to filmless image management systems and review stations. In addition, afull line <strong>of</strong> probes and conventional recording devices are available.1Pulmonary Medicine (PM) OPPF1 1 Ventilatory Test Room, SpirometryM2025 Rack, gas cylinder storage AR VV Rack, gas cylinder storage (PG-18-1, PG-18-6, MCS 05 50 00) #VALUE!Barometer, wall 1 VV Barometer, wall, 48” (1200 mm) high 1A5230 Fire blanket cabinet 1 VV Fure blanket cabinet 1E0954 Cart, emergency 1 VV Cart, emergency, “crash cart” approx. 36” x 21” (900 mm x 525 mm) 1M1801 PC, computer AR VV PC, computer system, with keyboard #VALUE!A5075 Dispenser, soap 1 VV Dispenser, soap, liquid, wall mounted 1M1801 & M18Computer and printer 1 VV Computer and printer 1M0700/ Machine, spirometry 1 VV Machine, spirometry with recorder and medical gas cylindersM0705 or1M0710F3200 Clock, atomic 1 VV Clock, atomic, battery operated 1M0520 Plethysmograph 1 VV Plethysmograph with separate medical gas cylinders 1Unit, diffusion AR VV Unit, diffusion #VALUE!Pulmonary Medicine (PM) OPPF5 1 Exercise RoomE0954 Cart, emergency 1 VV Cart, emergency, "crash cart" approx. 36” x 21” (900 mm x 525 mm) 1M1801/M182Desk top PC 1 VV Desk top PC, CRT, and printer 1E0210 Modular work station 1 VV Modular work station with under counter keyboard tray, overhead storage, and wall hanger strips. 1A5075 Dispenser, soap 1 VV Dispenser, soap, liquid, wall mounted 1M8125 Computer assisted recumbent bicycle aerobic trainer1 VV Computer assisted recumbent bicycle aerobic trainer1M8185 Machine, treadmill 1 VV Machine, treadmill, with controls, 120 volt, approx. 72” x 30” (1800 mm x 750 mm) 1M7710 Machine, twelve 1 VV Machine, twelve (12) leads "ECG" 1M0730 Metabolic cart 1 VV Metabolic cart 1F3200 Clock, atomic 1 VV Clock, atomic, battery operated 1M4116 Electronic sphygmomanometer (portable)1 VV Electronic sphygmomanometer (portable)1Cardiology OPTM1 1 Exercise Room (Stress Lab Facility)A5075 Dispenser, Soap, Disposable 1 VVDisposable soap dispenser. One-handed dispensing operation. Designed to accommodate disposable soap cartridge andvalve. 1A5106 Waste Disposal Unit, Sharpsw/Glove DispenserE0210 Worksurface, w/Overhead Cab,Wall Mtd, 48" W1 VV1 VVThe unit is designed for the disposal <strong>of</strong> sharps and complies with OSHA guidelines for the handling <strong>of</strong> sharps. It shall house a5 quart container and be capable <strong>of</strong> being mounted on a wall. It shall have a glove dispenser attached. The unit shall besecured by a locked enclosure.THIS TYPICAL INCLUDES:2 Vertical Hanging Strips1 Lockable Flipper Unit1 Shelf, Storage/Display1 Light1 Cantilevered Work Surface11______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 37 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameE0912 Locker, Supply, Med Surg, WallMtd2 VVItem DescriptionMedical/Surgical Supply locker, Wall Mounted, Approx 23"W x20"D. THIS TYPICAL INCLUDES:1 Locked Storage Container4 Tray/Shelves5 Drawers, 3"H (76mm)2 Drawers, 6"H (152mm)2 Tray/Shelf DividersDrawer Organizer BinsConsider the need for an E0921 to transport the locker from place to place.2E0954 Cart, Emergency, Mobile, 66"Hx 52"W x 22"D1 VVTHIS TYPICAL INCLUDES:1 Cart body, style-A narrow, w/raised edge top and breakaway lock bar w/tabs2 Accessory rails, side1 Accessory rail, back1 Defibrillator tray; 1 IV pole1 Flip-up shelf1 Wastebasket and holder1 Oxygen tank holder1 Cardiac board and hanger1 Electrical box-4 outlet1 Cord wrap4 Drawer, 3"H (76mm)3 Drawer, 6"H (152mm) Drawer organizer bins.1E1500 Rail, MOD, W/MNTD,HX144XDF3200 Clock, Battery, 12" Diameter 1 VV1 CC Wall mounted rail used for hanging (mounting) lockers, shelves drawers on a wall. 1Clock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 1M0750 Flowmeter, Air, Connect w/50PSI Supply1 VVAir flowmeter. Unit has a stainless steel needle valve with clear flowtube for connection to 50 PSI air outlet from centralpipeline system. Requires the appropriate adapter for connection to the wall outlet and fitting to connect to tubing. Databaseprices reflect fittings with an attached DISS power outlet. Other outlet and adapter configurations are available. 1M0755 Flowmeter, Oxygen, Low Flow 1 VVM0765 Regulator, Vacuum 1 VVOxygen flowmeter. Consists <strong>of</strong> a clear crystal flowtube calibrated to 3.5 or 8 LPM depending on manufacturer. For oxygenregulation in hospital settings. Database pricing includes DISS fitting and DISS power outlet and wall adapter. Other fittingand adapter configurations are available.An air/oxygen mixer is designed to accurately control a pressurized gas mixing with an oxygen concentration. Unit containsaudible alarms to warn <strong>of</strong> supply failure, an auxiliary outlet and a oxygen concentration control adjustment range from 21% to100%. The unit can also be used to supply an accurate pre-mixed gas source to respiration or ventilator units. A specificapplication may require an additional air inlet filter/water trap.11M1620 Holder, Chart, Patient, Wall orDoor MountedM1801 Computer, Microprocessing,w/Flat Panel Monitor1 CC1 VVWall or door mounted patient chart holder. Constructed <strong>of</strong> durable plastic or metal. Used for holding patient records. Size asrequired. 1Desk top microprocessing computer. The unit shall consist <strong>of</strong> a central processing mini tower, flat panel monitor, keyboard,mouse and speakers. The system shall have the following minimum characteristics: a 2.8 GHz Pentium processor; 512 MBmemory; 80GB hard drive; 32/48x CD-ROMDVD combo; a 3.5" floppy drive; 1.44MB network interface card; video 32 MBNVIDIA; a 15 inch flat panel color monitor. The computer is used throughout the facility to input, manipulate and retrieveinformation.1M1825 Printer, Computer 1 VVM4116 Monitor, Vital Signs 1 VVHigh resolution computer printer with a variety <strong>of</strong> type styles and sheet/envelope feeder trays. Database information reflectsnetwork ready, medium duty <strong>of</strong>fice style laser printers. Other types <strong>of</strong> printers (bubble jet, dot matrix, line or plotter) as wellas light or heavy use capabilities are available.Electronic sphygmomanometer. LCD displays non-invasive blood pressure, pulse rate and temperature. Used in hospitalsand clinics. Includes an optional mobile stand. 11______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 38 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameM4255 Stand, IV, Adjustable 1 VVM7660 Defibrillator/Monitor/Recorder,PortableM7710 Electrocardiograph, 12 Lead,Portable1 VV1 VVM8133 Ergometer, Upper Body 1 VVM8185 System, Stress Exercise,w/Treadmill1 VVItem DescriptionAdjustable IV stand with 4-hook arrangement. Stand has stainless steel construction with heavy weight base. It adjusts from66 inches to 100 inches and is mounted on conductive rubber, ball bearing, swivel casters. Stand is used for administeringintravenous solutions.Portable defibrillator-monitor-recorder. Integral unit system operable from self-contained rechargeable batteries. ECG maybe viewed through paddles or patient cable. Options include external pacing and 12-Lead. 1Used to detect the electrical signals associated with cardiac activity, diagnose cardiac abnormalities, determine a patientsresponse to drug therapy and reveal trends or changes in heart function. Capable <strong>of</strong> recording two or more leadssimultaneously, recording an entire 12 lead ECG in about 10 seconds. Includes <strong>of</strong> a 3.5 inch, high density, floppy disk drivefor test storage. Portable.Ergometer for measuring upper body exertion during an exercise regimen. The unit consists <strong>of</strong> a seat and a hand crankmechanism at shoulder height. The unit is used for physical rehabilitation protocols and stress testing. The unit quantifiablymeasures the effort exerted by the patient.Stress exercise system with treadmill and respiratory/metabolic assessment. The system includes an ECG amplifier, chartrecorder, display, console, treadmill and modules for respiratory/metabolic assessment. Used to determine patient'sfunctional capacity, predict and diagnose cardiopulmonary and vascular diseases and for rehabilitation <strong>of</strong> patients b coveringfrom leg injuries or other type <strong>of</strong> illness. Some vendors require a NEMA 5-20R non-locking receptacle for their treadmills.1111Surgery-Ambulatory Surgery ORCS1 1 Cystoscopic RoomSurgery-Ambulatory Surgery ORCW1 1 OR: Clean Core-Staff WorkroomInsert items required for projecthere.Surgery-Ambulatory Surgery OREC1 1 Cystoscopy: Instrument Preparation and Storage RoomInsert items required for projecthere.Table, urological 1 VV Table, urological, radiographic. Motor driven, with x-ray tube support 1Console, control 1 VV Console, control 1Radiographic tube and high 1 VV Radiographic tube and high voltage cables, 500 ma. Single phase voltage1M1801 PC, computer 1 VV PC, computer system, with keyboard 1Monitor, video AR VV Monitor video #VALUE!M3185 Unit, electrocautery 1 VV Unit, electrocautery 1M4815 Unit, hyperihypothermia 1 VV Unit, hyperihypothermia 1E0954 cart, emergency 1 VV Cart, emergency, “crash cart" approx. 36” W x 21” D (900 mm W x 525 mm D) 1M0630 Machine, anesthesia1 VV Machine, anesthesia, portable equipment1M8800 Cart, Anesthesia equipment 1 VV Cart, anesthesia equipment 1M8755 Machine, suction 1 VV Machine, suction 1Surgery-Ambulatory Surgery ORGS1 2 OR: General Operating Room (OR)M1801 CRT, computer system 1 VV CRT, computer system, with keyboard 2Monitor, video AR VV Monitor, video, optional system. See Utility Plan Note 5. #VALUE!M3185 Unit, hyperihypothermia 1 VV Unit, hyperihypothermia 2E0954 Cart, emergency 1 VV Cart, emergency, “crash cart" approx. 36” W x 21” D (900 mm W x 525 mm D) 2M0630 Machine, anesthesia 1 VV Machine, anesthesia, portable 2M8800 Cart, Anesthesia equipment 1 VV Cart, anesthesia equipment 2M8755 Machine, suction 1 VV machine, suction 2AC: Orthopedics (Ortho) ORPC1 1 Storage, Plaster and SplintsNo Schdule F items 000______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 39 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionSurgery-Ambulatory Surgery ORPH2 3 OR: Holding Area, PatientSurgery-Minor Surgery ORPH2 1 Holding Area, PatientSurgery-Ambulatory Surgery ORSA1 1 Cystoscopy: Scrub-up AreaSurgery-Ambulatory Surgery ORSA1 1 OR: Scrub-up AreaSurgery-Minor Surgery ORSA1 1 Scrub Room / Sterilizer AreaSurgery-Ambulatory Surgery ORSR1 1 OR: Substerile RoomItem NameInsert items required for projecthere.Insert items required for projecthere.S0137 Sterilizer, electric single door 1 VVItem DescriptionSterilizer, electric single door, recessed through one wall, chamber size: 16” x 16” x 26”/3.8 cu. ft. (400 mm x 400 mm x 650mm/0.11m3). Provide water, compressed air, drain, electric and exhaust as required (PG-18-1, MCS 11 71 00).-or- 100A0125 Sterilizer, electric single door 1 VVSterilizer, electric single door, cabinet enclosed, chamber size: 16” x 16” x 26”/3.8 cu. ft. (400 mm x 400 mm x 650mm/0.11M3). Provide water, compressed air, drain, electric and exhaust as required (PG-18-1, MCS 11 71 00). 1M3110 Cabinet, blanket and solutionwarming1 VVCabinet, blanket and solution warming, two heated compartments, electrical (service as required), recessed, 30” x 27” x 76”(750 mm x 675 mm x 1900 mm) (PG-18-1, MCS 11 53 71) 1A5075 Dispenser, soap 1 VV Dispenser, soap, liquid, wall mounted 1F3200 Clock, atomic 1 VV Clock, atomic, battery operated 1SPD: Clean ORSS1 1 Storage, Bulk and ReceivingSPD: Clean ORSS1 1 Storage, Sterile / NonsterileE0903 Locker, Supply, w/Shelves,Wall Mtd, 23"W x 20"DAR VVTHIS TYPICAL INCLUDES:1 Supply Locker1 Drawer, 9"H (229mm)4 Tray/ShelvesDrawer OrganizersConsider the need for an E0921 to transport the locker from place to place.#VALUE!E0906 Locker, Supply, General, WallMtd, 23"W x 20"DAR VVTHIS TYPICAL INCLUDES:1 Locked Storage Container2 Tray/Shelves1 Drawer, 3"H (76mm)3 Drawers, 6"H (152mm)2 Drawers, 9"H (229mm)1 Tray/Shelf DividerDrawer Organizer BinsConsider the need for an E0921 to transport the locker from place to place.#VALUE!Mental Health: Occupational Therapy OTDL1 1 Basic ClinicPMR: Occupational Therapy (OT) OTGC1 1 Treatment ClinicAUD: Audiology PEHS1 1 Booth, Audometric ExamE1500 Rail, MOD, W/MNTD,HX144XDInsert items required for projecthere.Insert items required for projecthere.3 VV Wall mounted rail used for hanging (mounting) lockers, shelves drawers on a wall. 600______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 40 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameF3200 Clock, Battery, 12" Diameter 1 VVItem DescriptionClock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 1M0030 Audiometer, Diagnostic 1 VVOne person audiometer. Unit includes talk over communication between operator and patient, automatic calibration,frequency and hearing level controls. Unit may require an external printer. Used for clinical audiological testing. 1M4200 Otoscope/Ophthalmoscope,Wall Mounted1 VVWall mounted otoscope and ophthalmoscope. Includes 6 foot line cord and plug and accepts and includes two handles.Contains head turn-on/turn-<strong>of</strong>f, built-in speculum tray and 8 foot coiled cords. Unit is designed for use in patient exam rooms. 1AUD: Audiology PESH4 1 Suite, Audiometric ExamF3200 Clock, Battery, 12" Diameter 1 VVClock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 1M0010 Recorder, Tape, w/DelayedAudio Feedback1 VVDelayed audio feedback tape recorder. Unit consists <strong>of</strong> a recorder and playback mechanism which delays speech playbackso the patient can directly associate what was said with how it sounds. The unit includes a delay mode/time selector,amplifier and microphone. Electrical specifications are for an optional battery recharger. Some manufacturers equipmentrequires an ancillary computer for operation; refer to the specific maker's literature. See JSN M1800 for computer equipment.Used for speech modification training and therapy.1M0025 Audiometer, Diagnostic, MiddleEar, Impedance1 VVDiagnostic impedance audiometer. Unit includes a clinical ear analyzer and can link to a complete data base computersystem that stores patient results. Used for diagnostic audiological testing for middle ear impedance / compliance. 1M0030 Audiometer, Diagnostic 1 VVOne person audiometer. Unit includes talk over communication between operator and patient, automatic calibration,frequency and hearing level controls. Unit may require an external printer. Used for clinical audiological testing. 1M0041 Booth, Audio, Double Wall,Suite1 CCDouble wall audiometric testing suite with double walled examination and control rooms. Unit includes recessedincandescent lights, carpet, keyed locks on both outer doors, a twelve outlet surface mounted plug mold strip in both rooms.A 24"x30" viewing window and self contained ventilation system permit extended examinations. Unit also includes jack panelbetween the exam and control rooms. Height may require raising room ceiling.1M1801 Computer, Microprocessing,w/Flat Panel Monitor1 VVDesk top microprocessing computer. The unit shall consist <strong>of</strong> a central processing mini tower, flat panel monitor, keyboard,mouse and speakers. The system shall have the following minimum characteristics: a 2.8 GHz Pentium processor; 512 MBmemory; 80GB hard drive; 32/48x CD-ROMDVD combo; a 3.5" floppy drive; 1.44MB network interface card; video 32 MBNVIDIA; a 15 inch flat panel color monitor. The computer is used throughout the facility to input, manipulate and retrieveinformation.1M1825 Printer, Computer 1 VVM4200 Otoscope/Ophthalmoscope,Wall Mounted1 VVHigh resolution computer printer with a variety <strong>of</strong> type styles and sheet/envelope feeder trays. Database information reflectsnetwork ready, medium duty <strong>of</strong>fice style laser printers. Other types <strong>of</strong> printers (bubble jet, dot matrix, line or plotter) as wellas light or heavy use capabilities are available.Wall mounted otoscope and ophthalmoscope. Includes 6 foot line cord and plug and accepts and includes two handles.Contains head turn-on/turn-<strong>of</strong>f, built-in speculum tray and 8 foot coiled cords. Unit is designed for use in patient exam rooms. 11Pharmacy: Secure Areas PHBS1 1 Drug Receiving, Breakdown and Verification AreaInsert items required for projecthere.Pharmacy: Secure Areas PHBS2 1 Oncology: Storage and Clean / Decontamination AreaF3200 Clock, atomic 1 VV Clock, atomic, battery operated 1R6060 Refrigerator, biological 1 VV Refrigerator, biological, reach-in, with hinged glass doors, 30” W x 33” D x 81” H (750 mm W x 825 mm D x 2025 mm H) 10F3200 Clock, atomic 1 VV Clock, atomic, battery operated 1A5075 Dispenser, soap 1 VV Dispenser, soap, liquid, wall mounted 1M3150 Automated medication storage/dispensing unitAR VVAutomated medication storage/dispensing unit (cell), secure, approx. 27” W x 25” D x 78” H (675 mm W x 635 mm D x 1950mm H) #VALUE!______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 41 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameAC: Exam / Treatment Modules (ETM) PHDS1 5 NS: Prescription Receiving StationMental Health: Methadone MaintenancePHDS1 1 Methadone Dispensing PharmacyInsert items required for projecthere.Pharmacy: Secure Areas PHIV3 1 Oncology: Preparation AreaL2336 Biological safety cabinet 1 VVItem DescriptionBiological safety cabinet H12B2-48 (laminar flow), Class II; Type B-2, 100% direct exhausted air through the work-space. 48”W x 38” D x 72” H (1200 mm W x 950 mm D x 1800 mm H) (PG-18-1, PG-18-6; MCS 11 53 53) 10Cabinet, intravenous 1 VV Cabinet, intravenous (IV), visual clarity inspection, 30” W x 24” D (750 mm W x 600 mm D), 120 volts 1F3200 Clock, atomic 1 VV Clock, atomic, battery operated 1R6060 Refrigerator, biological 1 VV Refrigerator, biological, reach-in, with hinged glass doors, 30” W x 33” D x 81” H (750 mm W x 825 mm D x 2025 mm H) 1F3200 Clock, atomic 1 VV Clock, atomic, battery operated 1A5075 Dispenser, soap 1 VV Dispenser, soap, liquid, wall mounted 1Pharmacy: Secure Areas PHMP1 1 Extemporaneous CompoundingE0603 Shelf Unit, Pharmacy AR THIS TYPICAL INCLUDES:2 Vertical Hanging Strips#VALUE!3 3 Shelf, UnitPharmacy: Secure Areas PHMP2 1 Mail OutPharmacy: Secure Areas PHMP2 1 PrepackagingPharmacy: Secure Areas PHOD1 1 Filling and AssemblyPharmacy: Secure Areas PHOD2 1 DispensingPharmacy: Secure Areas PHOD2 1 Storage, ActiveE0603 Shelf Unit, Pharmacy AR THIS TYPICAL INCLUDES:2 Vertical Hanging Strips3 3 Shelf, UnitE0603 Shelf Unit, Pharmacy AR THIS TYPICAL INCLUDES:2 Vertical Hanging Strips3 3 Shelf, UnitA1095 Message Board, Digital 1 VV Digital message display board. Electronic 80 character display with data memory enclosed in analuminum frame. For use in areas like the pharmacy waiting room.A5075 Dispenser, Soap, Disposable 1 VV Disposable soap dispenser. One-handed dispensing operation. Designed to accommodate disposable soap cartridge andvalve. 2#VALUE!#VALUE!2A5106 Waste Disposal Unit, Sharpsw/Glove DispenserE0606 Shelf Unit, Pharmacy, Wall Mtd,88"Hx48"Wx9"DE0612 Shelf Unit, Pharmacy, Wall Mtd,88"Hx48"Wx16"D1 VV1 VV1 VVF2550 Shredder, Paper Heavy Duty 1 VVThe unit is designed for the disposal <strong>of</strong> sharps and complies with OSHA guidelines for the handling <strong>of</strong> sharps. It shall house a5 quart container and be capable <strong>of</strong> being mounted on a wall. It shall have a glove dispenser attached. The unit shall besecured by a locked enclosure.THIS TYPICAL INCLUDES:2 Vertical Hanging Strips3 3 Shelf, UnitTHIS TYPICAL INCLUDES:2 Vertical Hanging Strips3 3 Shelf, UnitShredder shall be able to process a minimum <strong>of</strong> 25 sheets <strong>of</strong> paper per pass at a minimum rate <strong>of</strong> 25 feet per minute. Theunit shall have a 16 inch throat to accept paper. Paper shall be shredded into 1/4 inch strips. 2222F3200 Clock, Battery, 12" Diameter 1 VVClock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 2______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 42 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameM1801 Computer, Microprocessing,w/Flat Panel Monitor1 VVItem DescriptionDesk top microprocessing computer. The unit shall consist <strong>of</strong> a central processing mini tower, flat panel monitor, keyboard,mouse and speakers. The system shall have the following minimum characteristics: a 2.8 GHz Pentium processor; 512 MBmemory; 80GB hard drive; 32/48x CD-ROMDVD combo; a 3.5" floppy drive; 1.44MB network interface card; video 32 MBNVIDIA; a 15 inch flat panel color monitor. The computer is used throughout the facility to input, manipulate and retrieveinformation.2M1825 Printer, Computer 1 VVM1830 Printer, Label, Pharmacy 1 VVM1855 Facsimile Machine 1 VVM3150 Distribution System,Medication, AutomaticM7265 Counter, Pill/Tablet,Automated, Counter Mounted1 VV1 VVHigh resolution computer printer with a variety <strong>of</strong> type styles and sheet/envelope feeder trays. Database information reflectsnetwork ready, medium duty <strong>of</strong>fice style laser printers. Other types <strong>of</strong> printers (bubble jet, dot matrix, line or plotter) as wellas light or heavy use capabilities are available.Label printer for use in pharmacy applications. The printer shall be bench top standing. It shall be flexible enough toaccommodate label sizes up to 4 inches, with a minimum print speed <strong>of</strong> 6 inches per second and a minimum resolution <strong>of</strong>203 dpi.Plain paper facsimile unit used to transmit printed matter or images over standard telephone lines. The unit operates at amodem speed <strong>of</strong> 33.6 Kbps and automatically recognizes and communicates with a variety <strong>of</strong> standard facsimile machines.Commonly referred to as "fax" unit.An automated dispensing system that provides controlled dispensing, inventory and security. Size and cost will varydependent on number <strong>of</strong> modules selected. 2Table mounted prescription counter device that counts tablets and capsules directly into the final container. The unit shallautomatically count and dispense tablets and capsules into a container with speed and accuracy.2222M7280 Dispensing System,Prescription, RoboticR6060 Refrigerator, Biological, SS, 2Door, 40 Cu Ft1 VV1 VVRobotic prescription dispensing system. System handles 200 tablets and capsules and delivers filled and labeled vials at arate <strong>of</strong> up to 100 prescriptions per hour. System uses a computer controlled robotic arm to fill vials directly from medicationdispensing cells.Biological refrigerator. This unit shall have a minimum volume <strong>of</strong> 40 cubic feet, double doors, stainless steel cooler storagewith stainless steel drawers, three adjustable shelves and one stationary stainless steel shelf. This refrigerator is used inresearch laboratories and hospital pharmacies for storage and dispensing <strong>of</strong> drugs. 22PMR: Physical Therapy (PT) PTEA1 1 Treatment Exercise AreaF3200 Clock, Battery, 12" Diameter 1 VVClock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 1G1026 Exercise Apparatus, WeightTraining, Multi-Station1 VVMulti-station weight training apparatus for physical development and rehabilitation. Unit features a variety <strong>of</strong> benches, pullbars, supports and seats grouped around a central frame containing one or more weight stacks. Each station is designed toexercise specific muscle groups. A person can perform an extensive weight training routine by moving around the apparatusfrom station to station. More than one person can use the apparatus simultaneously by training at different stations. Thenumber and types <strong>of</strong> exercises available depend on the specific model <strong>of</strong> equipment chosen. Greater system weightcapacities for high level athletic competition training are available on some models. The room ceiling may have to be raisedto accommodate this equipment. The database specifications refer to a higher end system with a large number <strong>of</strong> trainingstations and a standard weight set.1AC: Exam / Treatment Modules (ETM) RCA01 2 NS: Storage, Crash CartEndoscopy RCA01 1 Storage, Crash CartSurgery-Ambulatory Surgery RCA01 1 Storage, Crash CartSurgery-Minor Surgery RCA01 1 Storage, Crash CartE0954 Cart, Emergency, Mobile, 66"Hx 52"W x 22"D1 VVTHIS TYPICAL INCLUDES:1 Cart body, style-A narrow, w/raised edge top and breakaway lock bar w/tabs2 Accessory rails, side1 Accessory rail, back1 Defibrillator tray; 1 IV pole1 Flip-up shelf1 Wastebasket and holder1 Oxygen5______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 43 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameM7660 Defibrillator/Monitor/Recorder,Portable1 VVM7905 Oximeter, Pulse 1 VVM8770 Aspirator/Pressure Unit,General Purpose1 VVItem DescriptionPortable defibrillator-monitor-recorder. Integral unit system operable from self-contained rechargeable batteries. ECG maybe viewed through paddles or patient cable. Options include external pacing and 12-Lead. 5Pulse oximeter for continuous surveillance <strong>of</strong> patient pulse and oxygen saturation rates. Instrument features LED display,audio and visual alarms, automatic calibration and battery operation in case <strong>of</strong> power failure. Other applications include sleepstudies.General purpose suction/pressure apparatus. Double stainless steel console unit with a 1/8 HP motor, stand-mounted.Stands include 2 1/2" casters with chemical resistant top. Pumps suction capacity: 22 LPM. Unit includes collection bottle,bacteria f55AC: HAS (MAS) RECP1 1Central ReceptionCounter andSupplemental<strong>Office</strong> EquipmentAC: Exam / Treatment Modules (ETM) RECP1 5 HAS: Clinic Module Reception AreaAUD: Audiology and Speech Pathology RECP1 1 <strong>Office</strong>, Reception / Control ClerkEndoscopy RECP1 1 Reception AreaEye Clinic RECP1 1 Reception AreaMental Health: Administration RECP1 1 Reception / Control UnitProsthetics and Sensory Aids RECP1 1 Reception and Waiting AreaSurgery-Ambulatory Surgery RECP1 1 ReceptionSurgery-Minor Surgery RECP1 1 ReceptionF2540 Shredder, Paper, Security 1 VV Paper shredder, approximately 18" high X 15" wide X 12" deep with shredding unit and waste receptacle. 13F3200 Clock, Battery, 12" Diameter 1 VV Clock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 13M1605 Holder, Chart, 20 Each 1 VVM1801 Computer, Microprocessing,w/Flat Panel Monitor2 VVClinical chart holder cart. 20 chart capacity. 2 side-by-side tiers. May be ordered in various chart capacities. Constructed <strong>of</strong>heavy metal frames with vinyl laminated surfaces or painted panels. 3" casters with locks. Used to hold patient spring loadedcharts.Desk top microprocessing computer. The unit shall consist <strong>of</strong> a central processing mini tower, flat panel monitor, keyboard,mouse and speakers. The system shall have the following minimum characteristics: a 2.8 GHz Pentium processor; 512 MBmemory; 80GB hard drive; 32/48x CD-ROMDVD combo; a 3.5" floppy drive; 1.44MB network interface card; video 32 MBNVIDIA; a 15 inch flat panel color monitor. The computer is used throughout the facility to input, manipulate and retrieveinformation.1326M1820 Imprinter, Data Record, Electric 1 VVElectric data record imprinter. The device accepts embossed plastic patient cards in either the 50 column or the 80 columnformat and adjusts automatically for card size and form thickness. Device will provide clear readable impressions with acycle that is less than 1 second in length. Electro-mechanical design provides for a consistent impression that is independent<strong>of</strong> operator knowledge or technique. Unit may include a date/time stamp as an accessory.13M1840 Printer/Copier/Fax Combination 1 VV Multifunctional printer, fax, scanner and copier (PFC) all-in-one machine. 13Lobby RECP3 1 Information DeskF2540 Shredder, Paper, Security 1 VV Paper shredder, approximately 18" high X 15" wide X 12" deep with shredding unit and waste receptacle. 1F3200 Clock, Battery, 12" Diameter 1 VV Clock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 1M1605 Holder, Chart, 20 Each 1 VVClinical chart holder cart. 20 chart capacity. 2 side-by-side tiers. May be ordered in various chart capacities. Constructed <strong>of</strong>heavy metal frames with vinyl laminated surfaces or painted panels. 3" casters with locks. Used to hold patient spring loadedcharts.1______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 44 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameM1801 Computer, Microprocessing,w/Flat Panel Monitor2 VVItem DescriptionDesk top microprocessing computer. The unit shall consist <strong>of</strong> a central processing mini tower, flat panel monitor, keyboard,mouse and speakers. The system shall have the following minimum characteristics: a 2.8 GHz Pentium processor; 512 MBmemory; 80GB hard drive; 32/48x CD-ROMDVD combo; a 3.5" floppy drive; 1.44MB network interface card; video 32 MBNVIDIA; a 15 inch flat panel color monitor. The computer is used throughout the facility to input, manipulate and retrieveinformation.2M1820 Imprinter, Data Record, Electric 1 VVElectric data record imprinter. The device accepts embossed plastic patient cards in either the 50 column or the 80 columnformat and adjusts automatically for card size and form thickness. Device will provide clear readable impressions with acycle that is less than 1 second in length. Electro-mechanical design provides for a consistent impression that is independent<strong>of</strong> operator knowledge or technique. Unit may include a date/time stamp as an accessory.1M1840 Printer/Copier/Fax Combination 1 VV Multifunctional printer, fax, scanner and copier (PFC) all-in-one machine. 1HAS: <strong>Office</strong> Operation (Support ServiceRPR01 1 Copy RoomEndoscopy RROP1 2 Cubicle, Patient RecoverySurgery-Ambulatory Surgery RROP1 6 Cubicle, Patient RecoveryF2540 Shredder, Paper, Security 1 VV Paper shredder, approximately 18" high X 15" wide X 12" deep with shredding unit and waste receptacle. 1M1810 Copier, Floor Standing, Digital 1 VV Floor standing copier. Unit features automatic paper size selection, automatic document feeder and sorter. The system alsohas zoom capabilities and automatic two-sided copying. For use where medium volume reproduction is required in the range <strong>of</strong> 30 to 40 copies per minute.1Insert items required for projecthere.Surgery-Ambulatory Surgery RRSS1 1 Postanesthesia Recovery (PAR): Recovery BedSurgery-Minor Surgery RRSS1 1 Lounge, Postoperative RecoveryInsert items required for projecthere.AMMS: Administration SEC01 1 <strong>Office</strong> Secretary and WaitingAUD: Audiology and Speech Pathology SEC01 1 <strong>Office</strong> Secretary and WaitingClinic <strong>Management</strong> SEC01 1 <strong>Office</strong>, Secretary / ClerksClinic <strong>Management</strong> SEC01 2 <strong>Office</strong>, Secretary and WaitingDental SEC01 1 <strong>Office</strong>, Secretary to the MAO and WaitingEMS SEC01 1 <strong>Office</strong>, Secretary / Reception / Files / Additional ClerkHAS: <strong>Office</strong> <strong>of</strong> the Chief SEC01 1 <strong>Office</strong>, Secretary and WaitingMental Health: Administration SEC01 1 <strong>Office</strong>, Secretary and WaitingMental Health: Substance Abuse Clinic SEC01 1 <strong>Office</strong>, Secretary / ClericalPLM SEC01 1 <strong>Office</strong>, Secretary / ClericalPharmacy: Secure Areas SEC01 1 <strong>Office</strong>, Secretary / ClericalProsthetics and Sensory Aids SEC01 1 <strong>Office</strong>, Secretary and WaitingRadiology SEC01 1 <strong>Office</strong>, Secretary and WaitingService Organizations SEC01 2 <strong>Office</strong>, Secretary and WaitingVoluntary Service SEC01 1 <strong>Office</strong>, SecretaryA6046 Artwork, Decorative, WithFrame1 VV This JSN is to be used for determining and defining location <strong>of</strong> decorative artwork. 1700______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 45 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameE0099 Workstation, Corner Work Surf,Free Stand, 72x961 VVTHIS TYPICAL INCLUDES:4 Standard Solid Panel2 Panel-to-Panel Connectors1 Panel Connector, 2-Way Corner2 Finished End Hardware1 Cantilevered Corner Work Surface2 Cantilevered Work Surface3 Lockable Flipper Units3 Lights2 Tackboards2 Tool Rails2 Paper Trays1 Diagonal Tray1 Adjustable Keyboard Tray1 Mobile Pedestal, Box/File2 Support PanelsItem Description17F3200 Clock, Battery, 12" Diameter 1 VVClock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 17M1801 Computer, Microprocessing,w/Flat Panel Monitor1 VVDesk top microprocessing computer. The unit shall consist <strong>of</strong> a central processing mini tower, flat panel monitor, keyboard,mouse and speakers. The system shall have the following minimum characteristics: a 2.8 GHz Pentium processor; 512 MBmemory; 80GB hard drive; 32/48x CD-ROMDVD combo; a 3.5" floppy drive; 1.44MB network interface card; video 32 MBNVIDIA; a 15 inch flat panel color monitor. The computer is used throughout the facility to input, manipulate and retrieveinformation.17EMS SHRHM1 1 Infectious / Hazardous WasteAMMS: Acquistion and Distribution SHRM1 1 Storage, FlammableInsert items required for projecthere.Insert items required for projecthere. 0AC: Dermatology (Derm) SHWR1 1 Dermatology Phototherapy Shower RoomF3200 Clock, atomic 1 VV Clock, atomic, battery operated 1A5075 Dispenser, soap 1 VV Dispenser, soap, liquid, wall mounted 1M8192 Hand and foot UV light box 1 VV Hand and foot UV light box, on mobile stand, approx. 24” W x 24” D x 30” H (600 mm W x 600 mm D x 750 mm H) 10M1801 PC, computer 2 VV PC, computer system, with keyboard 2M7410/ M819Whole body UV light box 1 VV Whole body UV light box, approx. 4” (100 mm) diameter in closed position 1R7000 Refrigerator, domestic type 1 VV Refrigerator, domestic type, 15 cu ft (0.42 m3), approx. 31” x 28” x 66” (775 mm x 700 mm x 1650 mm) 1M3150 Automated supply storage.Dispensing unitAR VVCanteen Service SL001 1 Staff Lunch / Break RoomSurgery-Ambulatory Surgery SL001 1 OR: Lounge, Nurses and other OR StaffSurgery-Ambulatory Surgery SL001 1 OR: Lounge, Surgeons, Residents and StudentsA5075 Dispenser, Soap, Disposable AR VVAutomated supply storage/dispensing unit (cell), approx. 27” W x 25” D x 78” H (675 mm W x 635 mm D x 1950 mm H) eachcell #VALUE!Disposable soap dispenser. One-handed dispensing operation. Designed to accommodate disposable soap cartridge andvalve. #VALUE!F3200 Clock, Battery, 12" Diameter 1 VVClock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 3______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 46 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameK1552 Brewer, C<strong>of</strong>fee, Auto, Elect, 3Burner, Front/Back1 VVItem DescriptionSpace saving front to back automatic c<strong>of</strong>fee maker. This unit includes a heating tank, connection for a cold water supply,decanter service with three burners, funnel and a water flow controller. The unit is used for semi-automatic c<strong>of</strong>fee brewing incafeterias and commercial institutions. The unit automatically shuts <strong>of</strong>f the water flow when enough has passed through to fillthe pot. The unit is normally provided plumbed with a hot water faucet to the side for making other hot drinks (tea, cider,cocoa, etc.). The database height dimension does not include the clearance for c<strong>of</strong>fee decanters warming on the upperburners.3K4665 Oven, Microwave, Consumer 1 VVK8250 Toaster, Pop-Up, 4 Slice,Electric1 VVCounter mounted microwave oven for average duty use. The exterior cabinet can be metal or heavy duty impact resistantplastic. The oven delivers instant energy for rapid heating, defrosting or prime cooking. The oven has touch pad controls,digital timer, power level selector and preprogrammed selectors for commonly cooked items. This oven is commonly foundin staff lounges.Four (4) slice, electric pop-up toaster. The toaster casing is made from stainless steel and can produce up to 290 slices/hr.This is used to toast sliced bread in food service kitchens and hospital cafeteria operations. Several electrical powerconfigurations are available; some may require special wall receptacles. Refer to manufacturers' specifications. 33M0500 Television, Color, 20" Diagonal 1 VVColor television. Unit consists <strong>of</strong> a color receiver/monitor, with remote control, full <strong>of</strong>f-air channel capability, automatic lightsensor, broadcast stereo sound and automatic color balance. 3R7000 Refrigerator, 14 Cubic Feet 1 VVThis is a 14 Cubic Foot frostless top mount refrigerator/freezer approximately 64" H x 28" W x 29" D. Combination unit that isused in households or other areas where general purpose storage <strong>of</strong> perishable items is required. 3AUD: Audiology SRCH1 1 Instrument Calibration and Storage RoomA5075 Dispenser, soap 1 VV Dispenser, soap, liquid, wall mounted 1R7250 Refrigerator 1 VV Refrigerator, 120V 1Pharmacy: Secure Areas SRCS1 1 Storage, Prosthetic and Medical SuppliesProsthetics and Sensory Aids SRCS1 1 Prosthetic Appliance Storage: Mailing RoomProsthetics and Sensory Aids SRCS1 1 Prosthetic Appliance Storage: Storage RoomNo Schedule F Items NR 0AMMS: Acquistion and Distribution SRE01 1 Storage, EquipmentAC: HAS Medical Information Section SRE01 1 Supplemental Equipment SpaceAC: HAS Transcription Unit (TU) SRE01 1 Supplemental Equipment SpaceAC: Urgent Care SRE01 1 Storage, Medical EquipmentDental SRE01 1 Storage RoomPMR: Occupational Therapy (OT) SRE01 1 Storage, EquipmentPMR: Physical Therapy (PT) SRE01 1 Storage, EquipmentRadiology SRE01 1 Computed Tomography: Storage RoomSurgery-Ambulatory Surgery SRE01 2 OR: Storage, Equipment and ApparatusSurgery-Minor Surgery SRE01 1 Storage, Equipment and apparatusNo Schedule F Items NR 0AMMS: Acquistion and Distribution SRGC1 1 Storage, Medical GasSPD: Clean SRGC1 1 Storage, Ethylene Oxide Gas CylinderSurgery-Ambulatory Surgery SRGC1 3 OR: Storage, Gas Cylinder RoomSurgery-Minor Surgery SRGC1 1 Storage, Gas Cylinder RoomAMMS: Acquistion and Distribution SRHM1 1 Storage, Bio-hazard WastePharmacy: Secure Areas SRHM1 1 Storage, FlammableM2015 Cabinet, Storage, Flammable,FreestandingAR VVFreestanding flammable safety storage cabinet. Size as required. Unit is <strong>of</strong> all welded steel wall construction with ventedgrounding attachments, raised leak pro<strong>of</strong> door sill and adjustable shelving. Equipped with swinging doors and built-in keylock. Designed for storage <strong>of</strong> flammable fluids. Complies with OSHA standards, is FM approved and designed IAW NFPA30.#VALUE!______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 47 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameM2015 Cabinet, Storage, Flammable,FreestandingAR VVItem DescriptionFreestanding flammable safety storage cabinet. Size as required. Unit is <strong>of</strong> all welded steel wall construction with ventedgrounding attachments, raised leak pro<strong>of</strong> door sill and adjustable shelving. Equipped with swinging doors and built-in keylock. Designed for storage <strong>of</strong> flammable fluids. Complies with OSHA standards, is FM approved and designed IAW NFPA30.AC: Urgent Care SRLW1 1 Storage, Wheelchair and StretcherLobby SRLW1 1 Storage, WheelchairRadiology SRLW1 7 Waiting, Wheelchair and StretcherSurgery-Ambulatory Surgery SRLW1 3 OR: Storage, GurneySurgery-Minor Surgery SRLW1 1 Storage, GurneyNo Schedule F Items NR 0Pharmacy: Secure Areas SRR01 1 Refrigeration / Freezer AreaInsert items required for projecthere.PLM: Laboratories SRR02 1 Storage, RefrigeratedInsert items required for projecthere.AMMS: Acquistion and Distribution SRS01 1 Storage, Form / Processed StoresAC: Exam / Treatment Modules (ETM) SRS01 5 Storage, Linen, Stretcher and Medical EquipmentMental Health: Day Treatment Center SRS01 1 Social Activities Space / StorageMental Health: Occupational Therapy SRS01 1 StorageMental Health: Substance Abuse Clinic SRS01 1 Utility and StoragePLM: Laboratories SRS01 1 Storage, BulkService Organizations SRS01 1 StorageSurgery-Ambulatory Surgery SRS01 1 Postanesthesia Recovery (PAR): StorageVoluntary Service SRS01 1 StorageE0903 Locker, Supply, w/Shelves,Wall Mtd, 23"W x 20"D2 VVTHIS TYPICAL INCLUDES:1 Supply Locker1 Drawer, 9"H (229mm)4 Tray/ShelvesDrawer OrganizersConsider the need for an E0921 to transport the locker from place to place.#VALUE!0026E0906 Locker, Supply, General, WallMtd, 23"W x 20"D5 VVTHIS TYPICAL INCLUDES:1 Locked Storage Container2 Tray/Shelves1 Drawer, 3"H (76mm)3 Drawers, 6"H (152mm)2 Drawers, 9"H (229mm)1 Tray/Shelf DividerDrawer Organizer BinsConsider the need for an E0921 to transport the locker from place to place.65E1500 Rail, MOD, W/MNTD,HX144XDAUD: Audiology SRSE1 1 Equipment AreaClinic <strong>Management</strong> SRSE1 1 Support EquipmentEMS SRSE1 1 Storage, Environmental <strong>Management</strong> Supplies / Large EquipmentHAS: Fee Services Section SRSE1 1 Supplemental Equipment SpaceHAS: Medical Care Cost Revoery (MCCSRSE1 1 Supplemental Equipment Space3 VV Wall mounted rail used for hanging (mounting) lockers, shelves drawers on a wall. 39______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 48 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameSPD: Clean SRSE1 1 Storage, Equipment and Testing RoomE0903 Locker, Supply, w/Shelves,Wall Mtd, 23"W x 20"D3 VVItem DescriptionTHIS TYPICAL INCLUDES:1 Supply Locker1 Drawer, 9"H (229mm)4 Tray/ShelvesDrawer OrganizersConsider the need for an E0921 to transport the locker from place to place.18E0906 Locker, Supply, General, WallMtd, 23"W x 20"D2 VVTHIS TYPICAL INCLUDES:1 Locked Storage Container2 Tray/Shelves1 Drawer, 3"H (76mm)3 Drawers, 6"H (152mm)2 Drawers, 9"H (229mm)1 Tray/Shelf DividerDrawer Organizer BinsConsider the need for an E0921 to transport the locker from place to place.12E0912 Locker, Supply, Med Surg, WallMtd2 VVMedical/Surgical Supply locker, Wall Mounted, Approx 23"W x20"D. THIS TYPICAL INCLUDES:1 Locked Storage Container4 Tray/Shelves5 Drawers, 3"H (76mm)2 Drawers, 6"H (152mm)2 Tray/Shelf DividersDrawer Organizer BinsConsider the need for an E0921 to transport the locker from place to place.12E1500 Rail, MOD, W/MNTD,HX144XDPharmacy: Secure Areas SSS01 1 Storage, Controlled Substance / Secured DispensingInsert items required for projecthere.Mental Health: Methadone MaintenanceSSV01 1 Storage / VaultInsert items required for projecthere.Surgery-Ambulatory Surgery TLTF2 1 OR: Toilet / Shower Room, Female StaffSurgery-Ambulatory Surgery TLTM2 1 OR: Toilet / Shower Room, Male StaffEMS: LLTS TLTS1 1 Shower, Female StaffEMS: LLTS TLTS1 1 Shower, Male StaffSPD: Soiled TLTS1 1 Lockers, Toilet and Shower <strong>Facilities</strong>A5075 Dispenser, Soap, Disposable 1 VV2 VV Wall mounted rail used for hanging (mounting) lockers, shelves drawers on a wall. 12Disposable soap dispenser. One-handed dispensing operation. Designed to accommodate disposable soap cartridge andvalve. 500AC: HAS File Unit (FU) TLTU1 2 FU ToiletAC: Exam / Treatment Modules (ETM) TLTU1 2 Toilet, PublicAC: Exam / Treatment Modules (ETM) TLTU1 2 NS: Toilet, StaffAC: Gastroenterology (GI) TLTU1 1 Toilet, PatientAC: Oncology (ONC) TLTU1 1 Toilet, PatientAC: Womens's Health / GYN TLTU1 1 Toilet, PatientAUD: Audiology and Speech Pathology TLTU1 1 Toilet, PatientClinic <strong>Management</strong> TLTU1 1 Toilet, StaffDental TLTU1 1 Patient Toilet______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 49 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameEndoscopy TLTU1 3 Toilet, PatientLobby TLTU1 1 Toilet, Female, PublicLobby TLTU1 1 Toilet, Male, PublicEMS: LLTS TLTU1 10 Toilet, StaffMental Health: Administration TLTU1 1 Toilet, Patient FemaleMental Health: Administration TLTU1 1 Toilet Patient MaleMental Health: Administration TLTU1 1 Toilet, StaffMental Health: Methadone MaintenanceTLTU1 1 Toilet, Urine Specimen CollectionPLM: Laboratories TLTU1 1 Toilet, Urine Specimen CollectionPharmacy: Secure Areas TLTU1 1 Toilet, StaffPMR: Physical Therapy (PT) TLTU1 1 Toilet, PatientRadiology TLTU1 1 Computed Tomography: Toilet, PatientRadiology TLTU1 1 Ultrasound: Toilet, PatientSurgery-Ambulatory Surgery TLTU1 1 Postanesthesia Recovery (PAR): Toilet, StaffSurgery-Ambulatory Surgery TLTU1 2 Toilet, PatientSurgery-Minor Surgery TLTU1 2 Toilet, PatientSurgery-Minor Surgery TLTU1 2 Toilet, StaffA5075 Dispenser, Soap, Disposable AR VVItem DescriptionDisposable soap dispenser. One-handed dispensing operation. Designed to accommodate disposable soap cartridge andvalve. #VALUE!Endoscopy TREE1 2 EGD Procedure RoomA1132 Rail, Accessory Mounting,Length As Required1 VVHorizontal mounting rail will consist <strong>of</strong> lock mounting devices capable <strong>of</strong>; supporting up to 75 pounds each, beingrepositioned, and mounting and dismounting <strong>of</strong> equipment without the use <strong>of</strong> tools. The rail must be capable <strong>of</strong> supportingmedical equipment and accessories normally found in exam or patient rooms. The rail system must be capable <strong>of</strong> mountingand dismounting equipment without leaving or creating new holes in the finished surface <strong>of</strong> the wall.2A5075 Dispenser, Soap, Disposable 1 VVDisposable soap dispenser. One-handed dispensing operation. Designed to accommodate disposable soap cartridge andvalve. 2A5106 Waste Disposal Unit, Sharpsw/Glove DispenserE0906 Locker, Supply, General, WallMtd, 23"W x 20"DE0912 Locker, Supply, Med Surg, WallMtd1 VV1 VV1 VVThe unit is designed for the disposal <strong>of</strong> sharps and complies with OSHA guidelines for the handling <strong>of</strong> sharps. It shall house a5 quart container and be capable <strong>of</strong> being mounted on a wall. It shall have a glove dispenser attached. The unit shall besecured by a locked enclosure.Supply Locker w/ wire shelves, approximately 29"W x 20"D. THIS TYPICAL INCLUDES:1 Mobile Supply Locker1 Drawer, 6"H (152mm)5 Wire ShelvesMedical/Surgical Supply locker, Wall Mounted, Approx 23"W x20"D. THIS TYPICAL INCLUDES:1 Locked Storage Container4 Tray/Shelves5 Drawers, 3"H (76mm)2 Drawers, 6"H (152mm)2 Tray/Shelf DividersDrawer Organizer BinsConsider the need for an E0921 to transport the locker from place to place.222E0918 Locker, Supply, Endoscopy,Wall Mtd, 24"W x 14"D1 VVTHIS TYPICAL INCLUDES:1 Scope Storage Cabinet w/Lock1 Bracket, Endoscope1 Bracket, Distal Tube1 Cabinet Drip Pan.E1500 Wall Mounting Rail is requiredConsider the need for an E0921 to transport the locker from place to place.2______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 50 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameE0948 Cart, General Storage, Mobile,42"H x 32"W x 22"D1 VVTHIS TYPICAL INCLUDES:1 Cart Body, Style-A Narrow, w/Raised Edge Top1 Accessory Rail, Side2 Drawers, 3" H (76mm)4 Drawers, 6" H (152mm)Drawer Organizer BinsItem Description2E0954 Cart, Emergency, Mobile, 66"Hx 52"W x 22"D1 VVTHIS TYPICAL INCLUDES:1 Cart body, style-A narrow, w/raised edge top and breakaway lock bar w/tabs2 Accessory rails, side1 Accessory rail, back1 Defibrillator tray; 1 IV pole1 Flip-up shelf1 Wastebasket and holder1 Oxygen tank holder1 Cardiac board and hanger1 Electrical box-4 outlet1 Cord wrap4 Drawer, 3"H (76mm)3 Drawer, 6"H (152mm)Drawer organizer bins.2E1500 Rail, MOD, W/MNTD,HX144XDF3200 Clock, Battery, 12" Diameter 1 VV1 VV Wall mounted rail used for hanging (mounting) lockers, shelves drawers on a wall. 2Clock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 2M0750 Flowmeter, Air, Connect w/50PSI Supply1 VVAir flowmeter. Unit has a stainless steel needle valve with clear flowtube for connection to 50 PSI air outlet from centralpipeline system. Requires the appropriate adapter for connection to the wall outlet and fitting to connect to tubing. Databaseprices reflect fittings with an attached DISS power outlet. Other outlet and adapter configurations are available. 2M0755 Flowmeter, Oxygen, Low Flow 1 VVM0765 Regulator, Vacuum 1 VVOxygen flowmeter. Consists <strong>of</strong> a clear crystal flowtube calibrated to 3.5 or 8 LPM depending on manufacturer. For oxygenregulation in hospital settings. Database pricing includes DISS fitting and DISS power outlet and wall adapter. Other fittingand adapter configurations are available.An air/oxygen mixer is designed to accurately control a pressurized gas mixing with an oxygen concentration. Unit containsaudible alarms to warn <strong>of</strong> supply failure, an auxiliary outlet and a oxygen concentration control adjustment range from 21% to100%. The unit can also be used to supply an accurate pre-mixed gas source to respiration or ventilator units. A specificapplication may require an additional air inlet filter/water trap.22M1801 Computer, Microprocessing,w/Flat Panel Monitor1 VVDesk top microprocessing computer. The unit shall consist <strong>of</strong> a central processing mini tower, flat panel monitor, keyboard,mouse and speakers. The system shall have the following minimum characteristics: a 2.8 GHz Pentium processor; 512 MBmemory; 80GB hard drive; 32/48x CD-ROMDVD combo; a 3.5" floppy drive; 1.44MB network interface card; video 32 MBNVIDIA; a 15 inch flat panel color monitor. The computer is used throughout the facility to input, manipulate and retrieveinformation.2M1802 Work Station, Computer,Retractable, Wall MountedM3160 Cabinet, Storage, HangingScopesM3175 Electrosurgical Unit, DualOutput1 VV1 VV1 VVA wall mounted retractable work station. Work station is used as a computer station in treatment rooms, exam rooms andareas where physical space in limited. 2Scope hanging cabinet. Cabinet has the capacity to hold up to nine scopes. Some cabinets may have a roll top closure andoptional storage drawer. 2Dual output electrosurgical unit. Solid state power source with foot switch jacks, monopolar and bipolar outputs, and fourindependent modes <strong>of</strong> operation. Used in the operating room or surgicenter as an alternative to the scalpel for cutting tissue. 2M4116 Monitor, Vital Signs 1 VVElectronic sphygmomanometer. LCD displays non-invasive blood pressure, pulse rate and temperature. Used in hospitalsand clinics. Includes an optional mobile stand. 2______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 51 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameM4255 Stand, IV, Adjustable 1 VVM4266 Pump, Volumetric, Infusion,Multiple Line1 VVItem DescriptionAdjustable IV stand with 4-hook arrangement. Stand has stainless steel construction with heavy weight base. It adjusts from66 inches to 100 inches and is mounted on conductive rubber, ball bearing, swivel casters. Stand is used for administeringintravenous solutions.Volumetric infusion pump. Pump is self-regulating with automatic sensor and adjustable rate. Equipped with visual andaudible alarms and up to 10 hour capacity battery. For the administration <strong>of</strong> a wide variety <strong>of</strong> therapeutic agents whereprecise control is required. Unit provides individual control to IV lines simultaneously. 22M7660 Defibrillator/Monitor/Recorder,Portable1 VVM7905 Oximeter, Pulse 1 VVPortable defibrillator-monitor-recorder. Integral unit system operable from self-contained rechargeable batteries. ECG maybe viewed through paddles or patient cable. Options include external pacing and 12-Lead. 2Pulse oximeter for continuous surveillance <strong>of</strong> patient pulse and oxygen saturation rates. Instrument features LED display,audio and visual alarms, automatic calibration and battery operation in case <strong>of</strong> power failure. Other applications include sleepstudies, exercise testing and monitoring certain patients in the home (e.g. infants or patients requiring respiratory therapy). 2M8517 Enteroscope, Fiberoptic,Therapeutic1 VVFlexible fiberoptic enteroscope. This scope is designed for small bowel exploration, washing, biopsy or tissue removal andsuctioning. Unit consists <strong>of</strong> a thin flexible casing with a suction adapter, an instrument channel, light guides, an air/waterchannel, an objective lens with an optical image fiber cluster, an eyepiece and a cable for connection to a light source.Casings and instrument channels can have varying dimensions depending on enteroscope design and intended procedure.Sonde-type scopes feature a second water channel for balloon cuff inflation.2M8607 Endoscopy Cart, Fiberoptic,w/Video, Info. Mgmt.1 VVEndoscopy cart with video and print capabilities for use with fiberoptic (direct vision) endoscopes. This cart does not workwith videoscopes. System takes optical images from a single endoscope and directly records them or converts them to digitalsignals for recording. A typical system cart includes the cart, a light source, an insufflator, a suction unit, a heat probe unit, anelectrosurgical apparatus, a digital camera converter or color video camera, a camera controller, a monitor, a video recorderand a color printer. This JSN does not include the endoscope; refer to the endoscopes at JSNs M8500-M8550. Each cart cansupport one or more types <strong>of</strong> endoscope and should be specifically tailored to its intended use(s). This cart can be configuredto interface with a network endoscopy information management system; refer to JSN M8600. Database physical informationand pricing is for a higher cost system containing one <strong>of</strong> each <strong>of</strong> the above components.2X3990 Illuminator, Film, 4 Panels, WallMounted1 VVX-ray film illuminator approximately 20' H x 29' W x 6'' D. This is a double, wall mounted type unit with a continuous viewingsurface. The tension film grips are adjustable top and bottom with standard grip strip. The unit's balanced-light viewing isassured by the 32W circular fluorescent lamp. It provides 500 feet candles <strong>of</strong> cool operation across the entire 14" X 17"viewing surface. It is available with or without film-activated switch. The unit can be used in hospitals, examining rooms,satellite <strong>of</strong>fice or lab.2AUD: Audiology TREN1 1 Immittance RoomA1132 Rail, Accessory Mounting,Length As Required1 VVHorizontal mounting rail will consist <strong>of</strong> lock mounting devices capable <strong>of</strong>; supporting up to 75 pounds each, beingrepositioned, and mounting and dismounting <strong>of</strong> equipment without the use <strong>of</strong> tools. The rail must be capable <strong>of</strong> supportingmedical equipment and accessories normally found in exam or patient rooms. The rail system must be capable <strong>of</strong> mountingand dismounting equipment without leaving or creating new holes in the finished surface <strong>of</strong> the wall.1A5075 Dispenser, Soap, Disposable 1 VVDisposable soap dispenser. One-handed dispensing operation. Designed to accommodate disposable soap cartridge andvalve. 1A5106 Waste Disposal Unit, Sharpsw/Glove Dispenser1 VVThe unit is designed for the disposal <strong>of</strong> sharps and complies with OSHA guidelines for the handling <strong>of</strong> sharps. It shall house a5 quart container and be capable <strong>of</strong> being mounted on a wall. It shall have a glove dispenser attached. The unit shall besecured by a locked enclosure.1______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 52 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameE0915 Locker, Supply, Medication,Wall Mtd, 23"W x 20"D1 VVItem DescriptionTHIS TYPICAL INCLUDES:1 Locked Storage Container2 Tray/Shelves1 Locker Drawer w/Locked Lid, 6"H (152mm)5 Drawers, 3"H (76mm)3 Drawers, 6"H (152mm)2 Tray/Shelves DividerDrawer Organizer BinsConsider the need for an E0921 to transport the locker from place to place.1E0954 Cart, Emergency, Mobile, 66"Hx 52"W x 22"D1 VVTHIS TYPICAL INCLUDES:1 Cart body, style-A narrow, w/raised edge top and breakaway lock bar w/tabs2 Accessory rails, side1 Accessory rail, back1 Defibrillator tray; 1 IV pole1 Flip-up shelf1 Wastebasket and holder1 Oxygen tank holder1 Cardiac board and hanger1 Electrical box-4 outlet1 Cord wrap4 Drawer, 3"H (76mm)3 Drawer, 6"H (152mm) Drawer organizer bins.1E1500 Rail, MOD, W/MNTD,HX144XDF3200 Clock, Battery, 12" Diameter 1 VV1 VV Wall mounted rail used for hanging (mounting) lockers, shelves drawers on a wall. 1Clock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 1M0750 Flowmeter, Air, Connect w/50PSI Supply1 VVAir flowmeter. Unit has a stainless steel needle valve with clear flowtube for connection to 50 PSI air outlet from centralpipeline system. Requires the appropriate adapter for connection to the wall outlet and fitting to connect to tubing. Databaseprices reflect fittings with an attached DISS power outlet. Other outlet and adapter configurations are available. 1M0755 Flowmeter, Oxygen, Low Flow 1 VVM0765 Regulator, Vacuum 1 VVOxygen flowmeter. Consists <strong>of</strong> a clear crystal flowtube calibrated to 3.5 or 8 LPM depending on manufacturer. For oxygenregulation in hospital settings. Database pricing includes DISS fitting and DISS power outlet and wall adapter. Other fittingand adapter configurations are available.An air/oxygen mixer is designed to accurately control a pressurized gas mixing with an oxygen concentration. Unit containsaudible alarms to warn <strong>of</strong> supply failure, an auxiliary outlet and a oxygen concentration control adjustment range from 21% to100%. The unit can also be used to supply an accurate pre-mixed gas source to respiration or ventilator units. A specificapplication may require an additional air inlet filter/water trap.11M1620 Holder, Chart, Patient, Wall orDoor MountedM1801 Computer, Microprocessing,w/Flat Panel Monitor1 VV1 VVWall or door mounted patient chart holder. Constructed <strong>of</strong> durable plastic or metal. Used for holding patient records. Size asrequired. 1Desk top microprocessing computer. The unit shall consist <strong>of</strong> a central processing mini tower, flat panel monitor, keyboard,mouse and speakers. The system shall have the following minimum characteristics: a 2.8 GHz Pentium processor; 512 MBmemory; 80GB hard drive; 32/48x CD-ROMDVD combo; a 3.5" floppy drive; 1.44MB network interface card; video 32 MBNVIDIA; a 15 inch flat panel color monitor. The computer is used throughout the facility to input, manipulate and retrieveinformation.1M1802 Work Station, Computer,Retractable, Wall Mounted1 VVA wall mounted retractable work station. Work station is used as a computer station in treatment rooms, exam rooms andareas where physical space in limited. 1______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 53 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameM4100 Sphygmomanometer, Aneroid,Wall Mounted1 VVM4116 Monitor, Vital Signs 1 VVItem DescriptionAneroid sphygmomanometer. Unit is wall mounted and has large graphic dial display for easy reading from all angles. It hasa 90 degree (angle) swivel and 10 degree (angle) forward tilt to reduce glare. Unit accuracy is within 1% <strong>of</strong> reading. Sturdyimpact-resistant construction.Electronic sphygmomanometer. LCD displays non-invasive blood pressure, pulse rate and temperature. Used in hospitalsand clinics. Includes an optional mobile stand. 11M4200 Otoscope/Ophthalmoscope,Wall Mounted1 VVWall mounted otoscope and ophthalmoscope. Includes 6 foot line cord and plug and accepts and includes two handles.Contains head turn-on/turn-<strong>of</strong>f, built-in speculum tray and 8 foot coiled cords. Unit is designed for use in patient exam rooms. 1M4266 Pump, Volumetric, Infusion,Multiple Line1 VVVolumetric infusion pump. Pump is self-regulating with automatic sensor and adjustable rate. Equipped with visual andaudible alarms and up to 10 hour capacity battery. For the administration <strong>of</strong> a wide variety <strong>of</strong> therapeutic agents whereprecise control is required. Unit provides individual control to IV lines simultaneously. 1M7405 Light, Exam, Ceiling Mounted 1 VVCeiling exam light. Consists <strong>of</strong> a lightheaded reflector supported by a ceiling mounted radial arm assembly that provides awide range <strong>of</strong> positioning capabilities. Halogen bulbs and an intensity control provide cool, color corrected light. Theminimum ceiling height in most cases is 8'-0"; refer to each manufacturer's specific installation requirements. Physicaldimensions refer to the retracted light; one length <strong>of</strong> the dual swing arm around the center mount in width and depth and thecombined height <strong>of</strong> the lamp head and folded arms. Unit may also have a center mount detachable and sterilizable controlhandle. For use in minor procedure or examination room applications.1M7660 Defibrillator/Monitor/Recorder,PortableM7710 Electrocardiograph, 12 Lead,Portable1 VV1 VVM7905 Oximeter, Pulse 1 VVPortable defibrillator-monitor-recorder. Integral unit system operable from self-contained rechargeable batteries. ECG maybe viewed through paddles or patient cable. Options include external pacing and 12-Lead. 1Used to detect the electrical signals associated with cardiac activity, diagnose cardiac abnormalities, determine a patientsresponse to drug therapy and reveal trends or changes in heart function. Capable <strong>of</strong> recording two or more leadssimultaneously, recording an entire 12 lead ECG in about 10 seconds. Includes <strong>of</strong> a 3.5 inch, high density, floppy disk drivefor test storage. Portable.Pulse oximeter for continuous surveillance <strong>of</strong> patient pulse and oxygen saturation rates. Instrument features LED display,audio and visual alarms, automatic calibration and battery operation in case <strong>of</strong> power failure. Other applications include sleepstudies, exercise testing and monitoring certain patients in the home (e.g. infants or patients requiring respiratory therapy). 11Eye Clinic TREY1 1 Exam / Treatment RoomM5730,M5600,M5530,M5545,M5520,M5535X3930 Illuminator, Film, Single, WallMounted1 VVStand, ophthalmic instrument 1 VVM5016 Desk, refraction 1 VVSingle film illuminator approximately 20"H x 17"W x 5"D. This is a single panel wall mounted unit. Characteristics andcomponents include, two 15 watt fluorescent tubes; gravity grip film holder, constructed <strong>of</strong> corrosion resistant galvanized steelwith stainless steel trim, and a clean uncluttered appearance. This unit is used to view X-ray film in hospitals and doctors<strong>of</strong>fices.Stand, ophthalmic instrument stand with swinging and pivoting arms continuing:* Phoroptor* Slit lamp* Keratometer* Lamp-top <strong>of</strong> ophthalmic columnDesk, refraction, with retractable lens drawer and controls and dimmer controls, power wells contains ophthalmoscope,retinoscope and transilluminator. Desk is pre-manufactured. 111M5560 Chart, projector 1 VV Chart, projector - top <strong>of</strong> the desk 1Sink, module 1 VV Sink, moduleNote: May be included in M5016. 1A5075 Dispenser, soap 1 VV Dispenser, soap, liquid, wall mounted 1A5106 Glove dispenser, wall mounted 1 VV Glove dispenser, wall mounted 1______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 54 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameItem DescriptionM5710 Mirror, set-2 AR VV Mirror, set - 2, reflecting, adjustable (special optometrist) #VALUE!M5720 Screen, reflecting AR VV Screen, reflecting, adjustable (special optometrist) #VALUE!M1801 PC, computer system 1 VV PC, computer system, with keyboard 1F3200 Clock, atomic 1 VV Clock, atomic, battery operated 1AC: Exam / Treatment Modules (ETM) TRGM1 2 Multipurpose Procedure RoomA1132 Rail, Accessory Mounting,Length As Required1 VVHorizontal mounting rail will consist <strong>of</strong> lock mounting devices capable <strong>of</strong>; supporting up to 75 pounds each, beingrepositioned, and mounting and dismounting <strong>of</strong> equipment without the use <strong>of</strong> tools. The rail must be capable <strong>of</strong> supportingmedical equipment and accessories normally found in exam or patient rooms. The rail system must be capable <strong>of</strong> mountingand dismounting equipment without leaving or creating new holes in the finished surface <strong>of</strong> the wall.2A5075 Dispenser, Soap, Disposable 1 VVDisposable soap dispenser. One-handed dispensing operation. Designed to accommodate disposable soap cartridge andvalve. 2A5106 Waste Disposal Unit, Sharpsw/Glove DispenserE0915 Locker, Supply, Medication,Wall Mtd, 23"W x 20"D1 VV1 VVThe unit is designed for the disposal <strong>of</strong> sharps and complies with OSHA guidelines for the handling <strong>of</strong> sharps. It shall house a5 quart container and be capable <strong>of</strong> being mounted on a wall. It shall have a glove dispenser attached. The unit shall besecured by a locked enclosure.THIS TYPICAL INCLUDES:1 Locked Storage Container2 Tray/Shelves1 Locker Drawer w/Locked Lid, 6"H (152mm)5 Drawers, 3"H (76mm)3 Drawers, 6"H (152mm)2 Tray/Shelves DividerDrawer Organizer BinsConsider the need for an E0921 to transport the locker from place to place.22E0954 Cart, Emergency, Mobile, 66"Hx 52"W x 22"D1 VVTHIS TYPICAL INCLUDES:1 Cart body, style-A narrow, w/raised edge top and breakaway lock bar w/tabs2 Accessory rails, side1 Accessory rail, back1 Defibrillator tray; 1 IV pole1 Flip-up shelf1 Wastebasket and holder1 Oxygen tank holder1 Cardiac board and hanger1 Electrical box-4 outlet1 Cord wrap4 Drawer, 3"H (76mm)3 Drawer, 6"H (152mm)Drawer organizer bins.2E1500 Rail, MOD, W/MNTD,HX144XDF3200 Clock, Battery, 12" Diameter 1 VV1 VV Wall mounted rail used for hanging (mounting) lockers, shelves drawers on a wall. 2Clock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 2M0750 Flowmeter, Air, Connect w/50PSI Supply1 WAir flowmeter. Unit has a stainless steel needle valve with clear flowtube for connection to 50 PSI air outlet from centralpipeline system. Requires the appropriate adapter for connection to the wall outlet and fitting to connect to tubing. Databaseprices reflect fittings with an attached DISS power outlet. Other outlet and adapter configurations are available. 2M0755 Flowmeter, Oxygen, Low Flow 1 VVOxygen flowmeter. Consists <strong>of</strong> a clear crystal flowtube calibrated to 3.5 or 8 LPM depending on manufacturer. For oxygenregulation in hospital settings. Database pricing includes DISS fitting and DISS power outlet and wall adapter. Other fittingand adapter configurations are available.2______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 55 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameM0765 Regulator, Vacuum 1 VVItem DescriptionAn air/oxygen mixer is designed to accurately control a pressurized gas mixing with an oxygen concentration. Unit containsaudible alarms to warn <strong>of</strong> supply failure, an auxiliary outlet and a oxygen concentration control adjustment range from 21% to100%. The unit can also be used to supply an accurate pre-mixed gas source to respiration or ventilator units. A specificapplication may require an additional air inlet filter/water trap.2M1801 Computer, Microprocessing,w/Flat Panel Monitor1 VVDesk top microprocessing computer. The unit shall consist <strong>of</strong> a central processing mini tower, flat panel monitor, keyboard,mouse and speakers. The system shall have the following minimum characteristics: a 2.8 GHz Pentium processor; 512 MBmemory; 80GB hard drive; 32/48x CD-ROMDVD combo; a 3.5" floppy drive; 1.44MB network interface card; video 32 MBNVIDIA; a 15 inch flat panel color monitor. The computer is used throughout the facility to input, manipulate and retrieveinformation.2M4100 Sphygmomanometer, Aneroid,Wall Mounted1 VVM4116 Monitor, Vital Signs 1 VVAneroid sphygmomanometer. Unit is wall mounted and has large graphic dial display for easy reading from all angles. It hasa 90 degree (angle) swivel and 10 degree (angle) forward tilt to reduce glare. Unit accuracy is within 1% <strong>of</strong> reading. Sturdyimpact-resistant construction.Electronic sphygmomanometer. LCD displays non-invasive blood pressure, pulse rate and temperature. Used in hospitalsand clinics. Includes an optional mobile stand. 22M4200 Otoscope/Ophthalmoscope,Wall Mounted1 VVWall mounted otoscope and ophthalmoscope. Includes 6 foot line cord and plug and accepts and includes two handles.Contains head turn-on/turn-<strong>of</strong>f, built-in speculum tray and 8 foot coiled cords. Unit is designed for use in patient exam rooms. 2M4266 Pump, Volumetric, Infusion,Multiple Line1 VVVolumetric infusion pump. Pump is self-regulating with automatic sensor and adjustable rate. Equipped with visual andaudible alarms and up to 10 hour capacity battery. For the administration <strong>of</strong> a wide variety <strong>of</strong> therapeutic agents whereprecise control is required. Unit provides individual control to IV lines simultaneously. 2M4655 Stretcher, Mobile, CRS, 9PositionM7660 Defibrillator/Monitor/Recorder,PortableM7710 Electrocardiograph, 12 Lead,Portable1 VV1 VV1 VVM7905 Oximeter, Pulse 1 VVMobile stretcher. All corrosion resistant stainless steel construction. It consists <strong>of</strong> a tubular frame with side rails, a 9-positionhydraulic base with pneumatic fowler adjustment, and a 2" pad. Unit is mounted on 8" conductive casters. Designed forpatient transport as well as for minor surgical procedures.Portable defibrillator-monitor-recorder. Integral unit system operable from self-contained rechargeable batteries. ECG maybe viewed through paddles or patient cable. Options include external pacing and 12-Lead. 2Used to detect the electrical signals associated with cardiac activity, diagnose cardiac abnormalities, determine a patientsresponse to drug therapy and reveal trends or changes in heart function. Capable <strong>of</strong> recording two or more leadssimultaneously, recording an entire 12 lead ECG in about 10 seconds. Includes <strong>of</strong> a 3.5 inch, high density, floppy disk drivefor test storage. Portable.Pulse oximeter for continuous surveillance <strong>of</strong> patient pulse and oxygen saturation rates. Instrument features LED display,audio and visual alarms, automatic calibration and battery operation in case <strong>of</strong> power failure. Other applications include sleepstudies, exercise testing and monitoring certain patients in the home (e.g. infants or patients requiring respiratory therapy). 222M8810 Stand, Mayo 1 VVX3930 Illuminator, Film, Single, WallMountedAC: Dermatology (Derm) TRGS1 1 Dermatology Procedure / Treatment RoomSurgery-Minor Surgery TRGS1 2 Minor Procedure / Operating Room (OR)A1132 Rail, Accessory Mounting,Length As Required1 VV1 VVAdjustable instrument table. Table is corrosion resistant stainless steel construction and is mounted on two casters with twoskid rails. It has telescopic upright adjusts from 39 inches to 60 inches with automatic locking device, and removable 13"x19"instrument tray. Designed for use in operating and procedure rooms.Single film illuminator approximately 20"H x 17"W x 5"D. This is a single panel wall mounted unit. Characteristics andcomponents include, two 15 watt fluorescent tubes; gravity grip film holder, constructed <strong>of</strong> corrosion resistant galvanized steelwith stainless steel trim, and a clean uncluttered appearance. This unit is used to view X-ray film in hospitals and doctors<strong>of</strong>fices.Horizontal mounting rail will consist <strong>of</strong> lock mounting devices capable <strong>of</strong>; supporting up to 75 pounds each, beingrepositioned, and mounting and dismounting <strong>of</strong> equipment without the use <strong>of</strong> tools. The rail must be capable <strong>of</strong> supportingmedical equipment and accessories normally found in exam or patient rooms. The rail system must be capable <strong>of</strong> mountingand dismounting equipment without leaving or creating new holes in the finished surface <strong>of</strong> the wall.223______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 56 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameA5075 Dispenser, Soap, Disposable 1 VVItem DescriptionDisposable soap dispenser. One-handed dispensing operation. Designed to accommodate disposable soap cartridge andvalve. 3A5106 Waste Disposal Unit, Sharpsw/Glove DispenserE0915 Locker, Supply, Medication,Wall Mtd, 23"W x 20"D1 VV1 VVThe unit is designed for the disposal <strong>of</strong> sharps and complies with OSHA guidelines for the handling <strong>of</strong> sharps. It shall house a5 quart container and be capable <strong>of</strong> being mounted on a wall. It shall have a glove dispenser attached. The unit shall besecured by a locked enclosure.THIS TYPICAL INCLUDES:1 Locked Storage Container2 Tray/Shelves1 Locker Drawer w/Locked Lid, 6"H (152mm)5 Drawers, 3"H (76mm)3 Drawers, 6"H (152mm)2 Tray/Shelves DividerDrawer Organizer BinsConsider the need for an E0921 to transport the locker from place to place.33E0954 Cart, Emergency, Mobile, 66"Hx 52"W x 22"D1 VVTHIS TYPICAL INCLUDES:1 Cart body, style-A narrow, w/raised edge top and breakaway lock bar w/tabs2 Accessory rails, side1 Accessory rail, back1 Defibrillator tray; 1 IV pole1 Flip-up shelf1 Wastebasket and holder1 Oxygen tank holder1 Cardiac board and hanger1 Electrical box-4 outlet1 Cord wrap4 Drawer, 3"H (76mm)3 Drawer, 6"H (152mm)Drawer organizer bins.3E1500 Rail, MOD, W/MNTD,HX144XDF3200 Clock, Battery, 12" Diameter 1 VV1 VV Wall mounted rail used for hanging (mounting) lockers, shelves drawers on a wall. 3Clock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 3M0750 Flowmeter, Air, Connect w/50PSI Supply1 VVAir flowmeter. Unit has a stainless steel needle valve with clear flowtube for connection to 50 PSI air outlet from centralpipeline system. Requires the appropriate adapter for connection to the wall outlet and fitting to connect to tubing. Databaseprices reflect fittings with an attached DISS power outlet. Other outlet and adapter configurations are available. 3M0755 Flowmeter, Oxygen, Low Flow 1 VVM0765 Regulator, Vacuum 1 VVOxygen flowmeter. Consists <strong>of</strong> a clear crystal flowtube calibrated to 3.5 or 8 LPM depending on manufacturer. For oxygenregulation in hospital settings. Database pricing includes DISS fitting and DISS power outlet and wall adapter. Other fittingand adapter configurations are available.An air/oxygen mixer is designed to accurately control a pressurized gas mixing with an oxygen concentration. Unit containsaudible alarms to warn <strong>of</strong> supply failure, an auxiliary outlet and a oxygen concentration control adjustment range from 21% to100%. The unit can also be used to supply an accurate pre-mixed gas source to respiration or ventilator units. A specificapplication may require an additional air inlet filter/water trap.33M1801 Computer, Microprocessing,w/Flat Panel Monitor1 VVDesk top microprocessing computer. The unit shall consist <strong>of</strong> a central processing mini tower, flat panel monitor, keyboard,mouse and speakers. The system shall have the following minimum characteristics: a 2.8 GHz Pentium processor; 512 MBmemory; 80GB hard drive; 32/48x CD-ROMDVD combo; a 3.5" floppy drive; 1.44MB network interface card; video 32 MBNVIDIA; a 15 inch flat panel color monitor. The computer is used throughout the facility to input, manipulate and retrieveinformation.3______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 57 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameM1802 Work Station, Computer,Retractable, Wall MountedM3185 Electrosurgical Unit, Monopolar,Wall Mounted1 VV1 VVItem DescriptionA wall mounted retractable work station. Work station is used as a computer station in treatment rooms, exam rooms andareas where physical space in limited. 3Wall mounted monopolar electrosurgical unit. It has a wall mounted hyfrecator. Unit features solid-state transistorizedcircuitry, dual power output, output dial with timer control, bipolar forceps, and isolated bipolar output. Unit has a monopolarmode where the current passes through an active cable and active electrode to the patient and back to the generator througha return electrode. It can be table mounted and is designed for routine applications in dermatology, gynecology, proctology,dentistry, podiatry and other clinical areas. Wall mounting bracket not included in system size.3M4116 Monitor, Vital Signs 1 VVElectronic sphygmomanometer. LCD displays non-invasive blood pressure, pulse rate and temperature. Used in hospitalsand clinics. Includes an optional mobile stand. 3M4200 Otoscope/Ophthalmoscope,Wall Mounted1 VVWall mounted otoscope and ophthalmoscope. Includes 6 foot line cord and plug and accepts and includes two handles.Contains head turn-on/turn-<strong>of</strong>f, built-in speculum tray and 8 foot coiled cords. Unit is designed for use in patient exam rooms. 3M4825 Cryosurgical Unit, Mobile 1 VVM7420 Light, Exam, Mobile 1 VVMobile cryosurgical unit. Cabinet mounted control unit, equipped with gas cylinder storage, foot switch, temperature gaugeand timer. Includes an integral pressure regulator, and choice <strong>of</strong> two gases. Cylinder size: 20 pound capacity. Unit includes2 tips.Mobile examination light mounted on a floor stand with casters. Unit features colored corrected light, an air-cooled shade anda balanced floating arm. Unit may also have a center mount detachable and sterilizable control handle. Designed forexamination, treatment, and emergency areas where cool, color-corrected light is needed. 33M9060 Table, Minor Surgery, Pedestal,4 Section, Mobile1 VVA 4-section, mobile, pedestal mounted minor surgery exam table. Pedestal is mounted on a base with locking casters. Tableis made from all stainless steel construction with chromium plated surfaces. Table has a foot control pedal for Trendelenburgand reverse Trendelenburg positions. Table padding is removable for cleaning. Table top consists <strong>of</strong> four hinged sections.Designed for minor operating rooms or outpatient surgery centers.3AC: Gastroenterology (GI) TRPE1 1 Screening Proctoscopy / Sigmoidoscopy RoomA1132 Rail, Accessory Mounting,Length As Required1 VVHorizontal mounting rail will consist <strong>of</strong> lock mounting devices capable <strong>of</strong>; supporting up to 75 pounds each, beingrepositioned, and mounting and dismounting <strong>of</strong> equipment without the use <strong>of</strong> tools. The rail must be capable <strong>of</strong> supportingmedical equipment and accessories normally found in exam or patient rooms. The rail system must be capable <strong>of</strong> mountingand dismounting equipment without leaving or creating new holes in the finished surface <strong>of</strong> the wall.1A5075 Dispenser, Soap, Disposable 1 VVDisposable soap dispenser. One-handed dispensing operation. Designed to accommodate disposable soap cartridge andvalve. 1A5106 Waste Disposal Unit, Sharpsw/Glove DispenserE0912 Locker, Supply, Med Surg, WallMtd1 VV1 VVThe unit is designed for the disposal <strong>of</strong> sharps and complies with OSHA guidelines for the handling <strong>of</strong> sharps. It shall house a5 quart container and be capable <strong>of</strong> being mounted on a wall. It shall have a glove dispenser attached. The unit shall besecured by a locked enclosure.Medical/Surgical Supply locker, Wall Mounted, Approx 23"W x20"D. THIS TYPICAL INCLUDES:1 Locked Storage Container4 Tray/Shelves5 Drawers, 3"H (76mm)2 Drawers, 6"H (152mm)2 Tray/Shelf DividersDrawer Organizer BinsConsider the need for an E0921 to transport the locker from place to place.11E1500 Rail, MOD, W/MNTD,HX144XDF3200 Clock, Battery, 12" Diameter 1 VV1 VV Wall mounted rail used for hanging (mounting) lockers, shelves drawers on a wall. 1Clock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 1______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 58 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameM0750 Flowmeter, Air, Connect w/50PSI Supply1 VVItem DescriptionAir flowmeter. Unit has a stainless steel needle valve with clear flowtube for connection to 50 PSI air outlet from centralpipeline system. Requires the appropriate adapter for connection to the wall outlet and fitting to connect to tubing. Databaseprices reflect fittings with an attached DISS power outlet. Other outlet and adapter configurations are available. 1M0755 Flowmeter, Oxygen, Low Flow 1 VVM0765 Regulator, Vacuum 1 VVOxygen flowmeter. Consists <strong>of</strong> a clear crystal flowtube calibrated to 3.5 or 8 LPM depending on manufacturer. For oxygenregulation in hospital settings. Database pricing includes DISS fitting and DISS power outlet and wall adapter. Other fittingand adapter configurations are available.An air/oxygen mixer is designed to accurately control a pressurized gas mixing with an oxygen concentration. Unit containsaudible alarms to warn <strong>of</strong> supply failure, an auxiliary outlet and a oxygen concentration control adjustment range from 21% to100%. The unit can also be used to supply an accurate pre-mixed gas source to respiration or ventilator units. A specificapplication may require an additional air inlet filter/water trap.11M1801 Computer, Microprocessing,w/Flat Panel Monitor1 VVDesk top microprocessing computer. The unit shall consist <strong>of</strong> a central processing mini tower, flat panel monitor, keyboard,mouse and speakers. The system shall have the following minimum characteristics: a 2.8 GHz Pentium processor; 512 MBmemory; 80GB hard drive; 32/48x CD-ROMDVD combo; a 3.5" floppy drive; 1.44MB network interface card; video 32 MBNVIDIA; a 15 inch flat panel color monitor. The computer is used throughout the facility to input, manipulate and retrieveinformation.1M1802 Work Station, Computer,Retractable, Wall Mounted1 VVM4116 Monitor, Vital Signs 1 VVA wall mounted retractable work station. Work station is used as a computer station in treatment rooms, exam rooms andareas where physical space in limited. 1Electronic sphygmomanometer. LCD displays non-invasive blood pressure, pulse rate and temperature. Used in hospitalsand clinics. Includes an optional mobile stand. 1M4266 Pump, Volumetric, Infusion,Multiple Line1 VVVolumetric infusion pump. Pump is self-regulating with automatic sensor and adjustable rate. Equipped with visual andaudible alarms and up to 10 hour capacity battery. For the administration <strong>of</strong> a wide variety <strong>of</strong> therapeutic agents whereprecise control is required. Unit provides individual control to IV lines simultaneously. 1M7420 Light, Exam, Mobile 1 VVMobile examination light mounted on a floor stand with casters. Unit features colored corrected light, an air-cooled shade anda balanced floating arm. Unit may also have a center mount detachable and sterilizable control handle. Designed forexamination, treatment, and emergency areas where cool, color-corrected light is needed. 1M7905 Oximeter, Pulse 1 VVPulse oximeter for continuous surveillance <strong>of</strong> patient pulse and oxygen saturation rates. Instrument features LED display,audio and visual alarms, automatic calibration and battery operation in case <strong>of</strong> power failure. Other applications include sleepstudies, exercise testing and monitoring certain patients in the home (e.g. infants or patients requiring respiratory therapy). 1M8605 Endoscopy Cart, Fiberoptic,Basic1 VVEndoscopic procedure cart. System contains a cart, light source, heat probe unit, electrosurgical unit, insufflator and asuction pump. This cart does not contain an endoscope or video equipment and does not support video endoscopes. Referto JSNs M8500-M8550 for endoscopes and JSNs M8606-M8607 for fiberoptic endoscope video carts. Each cart can supportone or more types <strong>of</strong> endoscopes and should be specifically tailored to its intended use. Database pricing and physicalinformation are for a higher cost system which contains one <strong>of</strong> each <strong>of</strong> the above components.1M8900 Carriage, Pail, CRS, WithoutPailM9065 Table, Examination, Proctology,Electro/Hydraulic1 VV Utility pail (kick bucket). Shall be a stainless steel 12 quart bucket for use in surgical operating rooms. 11 VVElectro-hydraulic proctology examination table. Unit consists <strong>of</strong> a stainless steel base with an Electro-hydraulic system andfoot controls. It includes a vacuum formed vinyl contoured top, a padded arm rest, an adjustable knee rest, a stainless steeldrainage pan and a built-in paper roll retainer/cutter. The table is designed for proctology, urology and OB/GYN exams. 1Pulmonary Medicine (PM) TRPE2 1 Special Procedures / Bronchoscopy RoomE0954 Cart, emergency 1 VV Cart, emergency, "crash cart" approx. 36” x 21” (900 mm x 525 mm) 1M1801/ M182Desk top PC 1 VV Desk top PC, CRT, and printer 1A5075 Dispenser, soap 1 VV Dispenser, soap, liquid, wall mounted 1______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 59 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameM8125 Computer assisted recumbentbicycle aerobic trainer1 VVItem DescriptionComputer assisted recumbent bicycle aerobic trainerM7710 Machine, twelve 1 VV Machine, twelve (12) leads "ECG" 1M0730 Metabolic cart 1 VV Metabolic cart 1F3200 Clock, atomic 1 VV Electro-hydraulic proctology examination table. Unit consists <strong>of</strong> a stainless steel base with an Electro-hydraulic system andfoot controls. It includes a vacuum formed vinyl contoured top, a padded arm rest, an Clock, atomic, battery operated 11M4116 Electronic sphygmomanometer(portable)1 VV Electronic sphygmomanometer (portable) 1AC: Exam / Treatment Modules (ETM) UCCL1 5 Clean Utility RoomEndoscopy UCCL1 1 Utility Room, CleanRadiology UCCL1 1 Utility Room, CleanSurgery-Ambulatory Surgery UCCL1 1 OR: Storage, Clean and Sterile SuppliesSurgery-Ambulatory Surgery UCCL1 1 Postanesthesia Recovery (PAR): Utility Room, CleanSurgery-Minor Surgery UCCL1 1 Storage, Clean And Sterile SuppliesE0903 Locker, Supply, w/Shelves,Wall Mtd, 23"W x 20"D3 VVTHIS TYPICAL INCLUDES:1 Supply Locker1 Drawer, 9"H (229mm)4 Tray/ShelvesDrawer OrganizersConsider the need for an E0921 to transport the locker from place to place.30E0906 Locker, Supply, General, WallMtd, 23"W x 20"D2 VVTHIS TYPICAL INCLUDES:1 Locked Storage Container2 Tray/Shelves1 Drawer, 3"H (76mm)3 Drawers, 6"H (152mm)2 Drawers, 9"H (229mm)1 Tray/Shelf DividerDrawer Organizer BinsConsider the need for an E0921 to transport the locker from place to place.20E0912 Locker, Supply, Med Surg, WallMtd2 VVMedical/Surgical Supply locker, Wall Mounted, Approx 23"W x20"D. THIS TYPICAL INCLUDES:1 Locked Storage Container4 Tray/Shelves5 Drawers, 3"H (76mm)2 Drawers, 6"H (152mm)2 Tray/Shelf DividersDrawer Organizer BinsConsider the need for an E0921 to transport the locker from place to place.20E1500 Rail, MOD, W/MNTD,HX144XDAC: Exam / Treatment Modules (ETM) USCL1 5 Soiled Utility RoomEndoscopy USCL1 1 Utility Room, SoiledRadiology USCL1 1 Utility Room, SoiledSurgery-Ambulatory Surgery USCL1 1 OR: Soiled Holding / Disposal RoomSurgery-Ambulatory Surgery USCL1 1 Postanesthesia Recovery (PAR): Utility Room, SoiledSurgery-Minor Surgery USCL1 1 Soiled Holding / Disposal Room2 VV Wall mounted rail used for hanging (mounting) lockers, shelves drawers on a wall. 20______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 60 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameE0903 Locker, Supply, w/Shelves,Wall Mtd, 23"W x 20"D3 VVItem DescriptionTHIS TYPICAL INCLUDES:1 Supply Locker1 Drawer, 9"H (229mm)4 Tray/ShelvesDrawer OrganizersConsider the need for an E0921 to transport the locker from place to place.30E0906 Locker, Supply, General, WallMtd, 23"W x 20"D2 VVTHIS TYPICAL INCLUDES:1 Locked Storage Container2 Tray/Shelves1 Drawer, 3"H (76mm)3 Drawers, 6"H (152mm)2 Drawers, 9"H (229mm)1 Tray/Shelf DividerDrawer Organizer BinsConsider the need for an E0921 to transport the locker from place to place.20E0912 Locker, Supply, Med Surg, WallMtd2 VVMedical/Surgical Supply locker, Wall Mounted, Approx 23"W x20"D. THIS TYPICAL INCLUDES:1 Locked Storage Container4 Tray/Shelves5 Drawers, 3"H (76mm)2 Drawers, 6"H (152mm)2 Tray/Shelf DividersDrawer Organizer BinsConsider the need for an E0921 to transport the locker from place to place.20E1500 Rail, MOD, W/MNTD,HX144XDEndoscopy USCL2 1 Scopes Clean-up, Sterilization and Storage RoomA5075 Dispenser, Soap, Disposable 1 VV2 VV Wall mounted rail used for hanging (mounting) lockers, shelves drawers on a wall. 20Disposable soap dispenser. One-handed dispensing operation. Designed to accommodate disposable soap cartridge andvalve. 1A5106 Waste Disposal Unit, Sharpsw/Glove DispenserE0912 Locker, Supply, Med Surg, WallMtd1 VV3 VVThe unit is designed for the disposal <strong>of</strong> sharps and complies with OSHA guidelines for the handling <strong>of</strong> sharps. It shall house a5 quart container and be capable <strong>of</strong> being mounted on a wall. It shall have a glove dispenser attached. The unit shall besecured by a locked enclosure.Medical/Surgical Supply locker, Wall Mounted, Approx 23"W x20"D. THIS TYPICAL INCLUDES:1 Locked Storage Container4 Tray/Shelves5 Drawers, 3"H (76mm)2 Drawers, 6"H (152mm)2 Tray/Shelf DividersDrawer Organizer BinsConsider the need for an E0921 to transport the locker from place to place.13EMS UTC01 1 Recyclable WastePMR: Physical Therapy (PT) UTLC1 1 Utility Room, CleanAC: HAS File Unit (FU) WRC01 1 FU Waiting AreaE1500 Rail, MOD, W/MNTD,HX144XDA5106 Waste Disposal Unit, Sharpsw/Glove DispenserInsert items required for projecthere.2 VV Wall mounted rail used for hanging (mounting) lockers, shelves drawers on a wall. 21 VVThe unit is designed for the disposal <strong>of</strong> sharps and complies with OSHA guidelines for the handling <strong>of</strong> sharps. It shall house a5 quart container and be capable <strong>of</strong> being mounted on a wall. It shall have a glove dispenser attached. The unit shall besecured by a locked enclosure.10______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 61 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionAC: Exam / Treatment Modules (ETM) WRC01 1 ETM Waiting AreaAUD: Audiology and Speech Pathology WRC01 1 Waiting AreaDental WRC01 1 Waiting AreaEndoscopy WRC01 1 Waiting AreaEye Clinic WRC01 1 Waiting Area (Dilation)Lobby WRC01 1 Waiting AreaMental Health: Methadone MaintenanceWRC01 1 Waiting AreaPLM: Laboratories WRC01 1 Waiting Area, PatientPharmacy: Non-Secure Areas WRC01 1 Waiting AreaPMR: WRC01 1 Waiting AreaRadiology WRC01 1 Waiting AreaItem NameA6046 Artwork, Decorative, WithFrameItem DescriptionAR VV This JSN is to be used for determining and defining location <strong>of</strong> decorative artwork. #VALUE!F2300 Rack, Magazine, Wall Mounted 1 VV Wall mounted magazine rack with nine (9) magazine holding compartments. 12F2420 Lamp, Table, With Shade 1 VV Table lamp, 27-34" high X 6" wide X 6" deep with linen shade. Convenience outlet required at point <strong>of</strong> use. 12F3200 Clock, Battery, 12" Diameter 1 VV Clock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 12M0510 TV/VCR Combination 1 VVAC: HAS File Unit (FU) WRCH1 1 WorkroomAUD: Speech Pathology (SP) WRCH1 1 Computer Assisted Traing (CAT) WorkroomVoluntary Service WRCH1 1 Volunteer Multipurpose RoomE0051 Workstation, Corner WorkSurface, Wall Mtd, 72x481 WTV/VCR Combination with Remote Control, The unit shall have the following minimum features: Front endaudio/video/earphone inputs jacks, on screen menu display, 181 channel tuning capability and video tracking adjustmentcapability.THIS TYPICAL INCLUDES:4 VERTICAL HANGING STRIPS2 LOCKABLE FLIPPER UNITS2 SHELF, STORAGE/DISPLAY2 LIGHT1 TACKBOARD2 TOOL RAIL2 PAPER TRAY1 DIAGONAL TRAY1 CANTILEVERED WORK SURFACE1 ADJUSTABLE KEYBOARD TRAY1 MOBILE PEDESTAL, BOX/FILE1 CPU HOLDER123F3200 Clock, Battery, 12" Diameter 1 WClock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 3M1801 Computer, Microprocessing,w/Flat Panel Monitor1 WDesk top microprocessing computer. The unit shall consist <strong>of</strong> a central processing mini tower, flat panel monitor, keyboard,mouse and speakers. The system shall have the following minimum characteristics: a 2.8 GHz Pentium processor; 512 MBmemory; 80GB hard drive; 32/48x CD-ROMDVD combo; a 3.5" floppy drive; 1.44MB network interface card; video 32 MBNVIDIA; a 15 inch flat panel color monitor. The computer is used throughout the facility to input, manipulate and retrieveinformation.3Surgery-Ambulatory Surgery WRF01 1 Waiting, Patient / FamilyM1825 Printer, Computer 1 WHigh resolution computer printer with a variety <strong>of</strong> type styles and sheet/envelope feeder trays. Database information reflectsnetwork ready, medium duty <strong>of</strong>fice style laser printers. Other types <strong>of</strong> printers (bubble jet, dot matrix, line or plotter) as wellas light or heavy use capabilities are available.3______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 62 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyRoomCodeDepartment / Functional AreaFunctionSurgery-Minor Surgery WRF01 1 Waiting, Patient and FamilyItem NameInsert items requried for projecthere.Item DescriptionRadiology XCTC1 1 Computed Tomography: Control RoomAir conditioning unit AR VV Air conditioning unit #VALUE!Computer cabinet, auxiliary AR VV Computer cabinet, auxiliary #VALUE!Computer cabinet, main AR VV Computer cabinet, main #VALUE!Power cabinet 1 VV Power cabinet 1Power line protector 1 VV Power line protector 1Transformer, high voltage 1 VV Transformer, high voltage 1Unit, power distribution 1 VV Unit, power distribution 1Radiology XCTS1 1 Computed Tomography: Computer / Power Equipment RoomRadiology XCTS1 1 Computed Tomography: Scanning RoomX6240 Radiographic unit,1 VV Radiographic unit, computerized tomography (CT) including gantry and mounting frame; table, patient and mounting frame computerized tomography2F3200 Clock, atomic 1 VV Clock, atomic, battery operated 2A5075 Dispenser, soap 1 VV Dispenser, soap, liquid, wall mounted 2X3150 Rack, glove/apron 1 VV Rack, glove/apron, wall mounted 2A5106 Glove dispenser 1 VV Glove dispenser, wall mounted 2A5106 Sharps container 1 VV Sharps container, wall mounted 2Radiology XDCS1 1 Chest Room - DedicatedDispenser, soap 1 VV Dispenser, soap, wall mounted with foot control (PG-18-1, MCS 10 28 00 1X5100 Automated CR chest unit 1 VV Automated CR chest unit consists <strong>of</strong> the following components as required:Bucky, tilt, wall mountedCabinet, rackCalculator, heat anodeConsole, controlModule, powerRails, tube, ceiling mountedStand, tube, ceiling mountedStarter, tube, high speedTransformer, high tension, x-rayUnit, chest, less tube standUnit, forced extinctionUnit, CR plate rotatorAutomated CR reader01F3200 Clock, atomic 1 VV Clock, atomic, battery operated 1X3150 Rack, glove/apron 1 VV Rack, glove/apron, wall mounted 1A5106 Sharps container 1 VV Sharps container, wall mounted 1A5106 Glove dispenser 1 VV Glove dispenser, wall mounted 1X3930 Illuminator, x-ray 1 VV Illuminator, x-ray, 120 volt, wall mounted, approx. 20” x 31” (500 mm x 775 mm), 2 in 1 1Surgery-Ambulatory Surgery XDCY1 1 Cystoscopy: External Radiographic Control RoomInsert items required for projecthere.0Radiology XDM01 1 Mammography Room______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 63 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameItem DescriptionX5430 Unit, mammography with chair 1 VV Unit, mammography with chair 1F3200 Clock, atomic 1 VV Clock, atomic, battery operated 1M1801 PC, computer system 1 VV PC, computer system, with keyboard 1A5075 Dispenser, soap 1 VV Dispenser, soap, liquid, wall mounted 1X3930 Illuminator, x ray 1 VV Illuminator, x ray, 120 volt, wall mounted, approx. 20" x 31" (500 mm x 775 mm), 2 in 1 1A5106 Sharps container 1 VV Sharps container, wall mounted 1A5106 Glove dispenser 1 VV Glove dispenser, wall mounted 1Radiology XDR01 1 General Purpose Radiology RoomA5075 Dispenser, Soap, Disposable 1 VV Disposable soap dispenser. One-handed dispensing operation. Designed to accommodate disposable soap cartridge andvalve. 0A5106 Waste Disposal Unit, Sharpsw/Glove Dispenser1 VVF3200 Clock, Battery, 12" Diameter 1 VVThe unit is designed for the disposal <strong>of</strong> sharps and complies with OSHA guidelines for the handling <strong>of</strong> sharps. It shall house a5 quart container and be capable <strong>of</strong> being mounted on a wall. It shall have a glove dispenser attached. The unit shall besecured by a locked enclosure.Clock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 00F3200 Clock, Battery, 12" Diameter 1 VVClock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 0X1405 Stand, Bucky, Vertical, Tilt,AutomaticX5900 (neeRadiographic Unit, 80 kW,NonTilt Table1 VV1 VVVertical and tilting bucky stand. This unit is mounted to the floor and wall to provide a vibration-free mounting platform for theuniversal bucky. The grid line free radiographs are produced at exposure times as short as two milliseconds. Characteristicsand components include aluminum interspaced grid with a 36 inch (914 mm) to 40 inch (1016 mm) focal range. The unit'scassette size sensing tray accommodates all cassette sizes between 5 and 17 inches. The unit tilts at angles <strong>of</strong> +90/-20degrees from the vertical position. The unit is used in X-ray facilities for processing radiography images.This system is specifically designed to perform radiographic examinations in the Radiology Department. This unitscharacteristics and components include, 80kW micro-processor controlled X-ray generator, a non-tilting table with a floatingtable top and an adjustable bucky, a ceiling suspended 0.6/1.2 mm tube unit and vertical bucky stand. 00Radiology XDRF1 1 Radiographic / Fluoroscopic (R/F) RoomDispenser, soap 1 VV Dispenser, soap, wall mounted with foot control (PG-18-1, MCS 10 28 00) 1Bracket, vacuum bottle 1 VV Bracket, vacuum bottle, slide (PG-18-1, MCS 22 62 00)Note: Outlets to be on the wall, near headend <strong>of</strong> x-ray table, 60” (1520 mm) above the floor. 1X6185 Radio/fluoro unit 1 VVRadio/fluoro unit – including the following components as required:Bucky, tilt, wall mountedConsole, control, x-ray, for radiographic unitRails, ceiling for tube carriage, universal mountRecorder, TV tapeStarter, tube, high speedSuspension system LCD monitorTable, 90 degree – 15 degree trendelenburg R&F, with spot film device (two-way or four-way table top and size <strong>of</strong> spot filmdevice to be determined on project basis)Table, tilt, 90 degree – 900 degree R&F, with spot film device (two-way or four-way table top and size <strong>of</strong> spot film device tobe determined on project basis)Transformer, high tension, x-rayTube carriage, ceiling mounted1Note: Optional components to be determined by Veterans Health Administration. 0F3200 Clock, atomic 1 VV Clock, atomic, battery operated 1______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 64 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)RoomDepartment / Functional Area Code FunctionRadiology XDUS1 1 Ultrasound RoomItem NameItem DescriptionQty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDispenser, soap 1 VVDispenser, soap, wall mounted with foot control (PG-18-1, MCS 10 28 00)Note: Outlets to be on the wall, near headend <strong>of</strong> x-ray table, 60” (1520 mm) above the floor. 1M1801 PC, computer system 1 VV PC, computer system, with keyboard 1X3930 Illuminator, x ray 1 VV Illuminator, x ray, 120 volt, wall mounted, approx. 20” x 59” (500 mm x 1475 mm), 4 in 1 1X2100 Scanner, ultrasonic AR VV Scanner, ultrasonic, mobile #VALUE!F3200 Clock, atomic 1 VV Clock, atomic, battery operated 1A5106 Glove dispenser, wall mounted 1 VV Glove dispenser, wall mounted 1A5106 Sharps container, wall mounted 1 VV Sharps container, wall mounted 1Endoscopy XVC01 1 Dictation / Viewing RoomRadiology XVC01 1 Common Viewing RoomF0690 Workstation, Computer,Enclosed, With Lock1 VVF3200 Clock, Battery, 12" Diameter 1 VVComputer operator workstation ,approximately 58" high X 36" wide X 25" deep. A fully enclosed workstation for a computer,monitor, printer and supplies. Cabinet has two lockable doors. 2Clock, 12" diameter. Round surface, easy to read numbers with sweep second hand. Wall mounted unit for use whenimpractical to install a fully synchronized clock system. Battery operated, (batteries not included). 2M0385 Projector, Multimedia/Data 1 VVM0507 Video TeleconferencingSystem1 VVThe projector shall provide computer and video projections. Minimum features included:Brightness <strong>of</strong> not less than 600 ANSI ( American National Standards Institute) Lumens, and a minimum resolution format <strong>of</strong>800 X 600 pixels (SVGA). The projector shall be portable and weigh no more than 10 pounds. It shall include a zoom lens andcomputer and video input ports.Shall be a video conferencing unit consisting <strong>of</strong> a camera, microphone, video/audio compression components, a componentcart and a 32 inch monitor. It shall provide live audio-visual conferencing capabilities to dispersed geographic sites. 22M1801 Computer, Microprocessing,w/Flat Panel Monitor1 VVDesk top microprocessing computer. The unit shall consist <strong>of</strong> a central processing mini tower, flat panel monitor, keyboard,mouse and speakers. The system shall have the following minimum characteristics: a 2.8 GHz Pentium processor; 512 MBmemory; 80GB hard drive; 32/48x CD-ROMDVD combo; a 3.5" floppy drive; 1.44MB network interface card; video 32 MBNVIDIA; a 15 inch flat panel color monitor. The computer is used throughout the facility to input, manipulate and retrieveinformation.2X4122 Console, PACS, Remote View,2k X 2k, 2 Monitors1 CFTwo monitor remote viewing station for picture and retrieval (DIN/PACS) system. This station is for use by providers inside oroutside radiology to review images. Station includes local image storage, image manipulation and simultaneous display <strong>of</strong>multiple images on a two 2058 X 2058 image display CRT's. Images are stored on a resident memory and roll <strong>of</strong>f to long termstorage as more recent images are sent to the station. Provider may request images from the PACS by LAN for image andresult receipt. Console must be DICOM compliant. Input may be by keyboard, mouse, trackball or voice activatedcommands.2Pharmacy: Secure Areas XXYYC 1 Oncology: Preparation Area AnteroomPharmacy: Secure Areas XXYYC 1 Oncology: Clean CorridorSurgery-Ambulatory Surgery XXYYC OR: Dedicated Electrical Room (if provided at Clean Core)Surgery XXYYC Corridors, Semi-Restricted (Peripheral)E0048 Workcenter, Computer, FreeStanding, 72" W1 VVTHIS TYPICAL INCLUDES:2 PAPER TRAY1 DIAGONAL TRAY1 TOOL RAIL1 FREESTANDING WORK SURFACE 24D X 72W1 MOBILE PEDESTAL, BOX/FILE1 ADJUSTABLE KEYBOARD TRAY2______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 65 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXVA FURNISHED EQUIPMENT GUIDE LIST (Excludes Schedule B Items)Qty <strong>of</strong> RoomsEquipment Symbol orJSN CodeQty per RoomAcquisition/ InstallationTotal QtyDepartment / Functional AreaRoomCodeFunctionItem NameM1801 Computer, Microprocessing,w/Flat Panel Monitor1 VVItem DescriptionDesk top microprocessing computer. The unit shall consist <strong>of</strong> a central processing mini tower, flat panel monitor, keyboard,mouse and speakers. The system shall have the following minimum characteristics: a 2.8 GHz Pentium processor; 512 MBmemory; 80GB hard drive; 32/48x CD-ROMDVD combo; a 3.5" floppy drive; 1.44MB network interface card; video 32 MBNVIDIA; a 15 inch flat panel color monitor. The computer is used throughout the facility to input, manipulate and retrieveinformation.2M1840 Printer/Copier/Fax Combination 1 VV Multifunctional printer, fax, scanner and copier (PFC) all-in-one machine. 2______Lessor Gov't_______VA FurnishedEquipment Guide List--Schedule F Page 66 <strong>of</strong> 66___ <strong>of</strong> _____ Pages


SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]THIS PAGE INTENTIONALLY LEFT BLANK FOR REPRODUCTION PURPOSES.Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!