� The analytical detection limit was retested in measuring tenfold dilution<br />
series of plasmid DNA of known concentration (1E+06-1E+02 copies/ ml)<br />
and the FTD Resp <strong>33</strong> multiplexes. (table 10).<br />
Table 10: Detection limit of plasmid DNA in tenfold measuring. It is given the amount of positive<br />
detected rating (x/10) and the accordant detection percentage (%).<br />
neg = not detected<br />
n.t. = not tested<br />
pathogen<br />
plasmid 10 6 cop/ml plasmid 10 5 cop/ml plasmid 10 4 cop/ml plasmid 10 3 cop/ml plasmid 10 2 x/10 % x/10 % x/10 % x/10 %<br />
cop/ml<br />
x/10 %<br />
FluA n.t. n.t. 10/10 100% 10/10 100% 9/10 90% 5/10 50%<br />
FluB n.t. n.t. 10/10 100% 10/10 100% 7/10 70% neg neg<br />
Rhino 10/10 100% 10/10 100% 10/10 100% 10/10 100% n.t. n.t.<br />
Para2 n.t. n.t. 10/10 100% 10/10 100% 10/10 100% 5/10 50%<br />
Para3 10/10 100% 10/10 100% 10/10 100% 10/10 100% n.t. n.t.<br />
Para4 10/10 100% 10/10 100% neg neg n.t. n.t. n.t. n.t.<br />
Cor63 10/10 100% 10/10 100% 10/10 100% 10/10 100% n.t. n.t.<br />
Cor229 10/10 100% 10/10 100% 10/10 100% 9/10 90% n.t. n.t.<br />
Cor43 n.t. n.t. 10/10 100% 10/10 100% 10/10 100% 7/10 70%<br />
HKU1 10/10 100% 10/10 100% 10/10 100% neg neg n.t. n.t.<br />
Para1 10/10 100% 10/10 100% 10/10 100% 10/10 100% n.t. n.t.<br />
Hump n.t. n.t. n.t. n.t. 10/10 100% 10/10 100% 10/10 100%<br />
Boca 10/10 100% 10/10 100% 10/10 100% 10/10 100% n.t. n.t.<br />
Mpneu n.t. n.t. 10/10 100% 10/10 100% 10/10 100% 7/10 70%<br />
Adeno 10/10 100% 10/10 100% 10/10 100% 9/10 90% 2/10 20%<br />
RSV A/B 10/10 100% 10/10 100% 10/10 100% 5/10 50% n.t. n.t.<br />
PV 10/10 100% 2/10 20% neg neg n.t. n.t. n.t. n.t.<br />
CMV 10/10 100% 10/10 100% 10/10 100% 10/10 100% n.t. n.t.<br />
EV 10/10 100% 10/10 100% 10/10 100% 9/10 90% n.t. n.t.<br />
Spneu<br />
Hib 10/10 100% 10/10 100% 10/10 100% 6/10 60%<br />
n.t.<br />
Saur 10/10 100% 10/10 100% 10/10 100% 3/10 30%<br />
Fast-track Diagnostics Luxembourg S.a.r.l.<br />
10/10 100% 10/10 100% 10/10 100% 4/10 40%<br />
Cpneu 10/10 100% 10/10 100% 10/10 100% 5/10 50%<br />
Legio<br />
10/10 100% 10/10 100% 10/10 100% 4/10 40%<br />
Kpneu 10/10 100% 10/10 100% 10/10 100% 1/10 10%<br />
n.t.<br />
PCP 10/10 100% 10/10 100% 9/10 90% 2/10 20%<br />
Salm 10/10 100% 10/10 100% 9/10 90% 3/10 30%<br />
Morax n.t. n.t. 10/10 100% 10/10 100% 10/10 100% 3/10 30%<br />
Bord 10/10 100% 10/10 100% 10/10 100% 9/10 90% n.t. n.t.<br />
FluC 10/10 100% 10/10 100% 10/10 100% 7/10 70% n.t. n.t.<br />
Haeinf 10/10 100% 10/10 100% 10/10 100% 9/10 90% n.t. n.t.<br />
� The endpoint detection limit of the multiplex PCR`s were compared to the<br />
singleplex PCR`s. Fivefold and tenfold diluted positive patient material was<br />
tested by singleplex and multiplex. All multiplex PCR`s show pretty similar<br />
detection limits than the singleplexes (table 11)<br />
Z. I. Langwies<br />
L-6131 Junglinster, Luxembourg,<br />
Tel. +352 780290 <strong>33</strong>2/329 Fax: +352 780290 514<br />
http://www.fast-trackdiagnostics.com/<br />