For Cpneu the “Instand Ringversuch for confirmation of chlamydia<br />

pneumoniae 2010” was analyzed with the new Respbac2 PPmix of the<br />

FTD Resp <strong>33</strong> test. (table 5)<br />

Table 5: “instand Ringversuch chlamydia pneumoniae 2010” All samples got<br />

dissolved accordant to the instand instruction and analyzed with the RespBac2 PPmix of<br />

the FTD Resp <strong>33</strong> test.<br />

samples<br />

2010<br />

1015401<br />

sample content<br />

Chlamydia pneumoniae<br />

1E+04 IFU/ml<br />

1015402 Haemophilus influenzae spp. Negative<br />

1015403 Escherichia coli Negative<br />

1015404<br />

Chlamydia pneumoniae<br />

1E+03 IFU/ml<br />

Fast-track Diagnostics Luxembourg S.a.r.l.<br />

Z. I. Langwies<br />

L-6131 Junglinster, Luxembourg,<br />

Tel. +352 780290 <strong>33</strong>2/329 Fax: +352 780290 514<br />

http://www.fast-trackdiagnostics.com/<br />

Page 8<br />

FTD Resp <strong>33</strong>/ RespBac2<br />

PPmix<br />

Detected (Cpneu)<br />

Detected (Cpneu)<br />

The “Instand Ringversuch for confirmation of bordetella pertussis 2010”<br />

was evaluated with the new MoBoCH PPmix of the FTD Resp <strong>33</strong> test.<br />

(table 6)<br />

Table 6: “instand Ringversuch bordetella pertussis 2010” All samples got<br />

dissolved accordant to the instand instruction and analyzed with the MoBoCH PPmix of<br />

the FTD Resp <strong>33</strong> test.<br />

samples<br />

2010<br />

sample content<br />

1015321 Escherichia coli Negative<br />

1015322<br />

1015323<br />

1015324<br />

Bordetella pertussis<br />

10 5 organisms/ml<br />

Bordetella pertussis<br />

10 4 organisms/ml<br />

Bordetella pertussis<br />

10 3 organisms/ml<br />

FTD Resp <strong>33</strong>/<br />

MoBoCH PPmix<br />

Detected (bord)<br />

Detected (bord)<br />

Detected (bord)<br />

� The specificity of salm was evaluated using a panel of 10 strains of<br />

Salmonella enterica. These 10 different serotypes represent the “top-ten”<br />

most frequently isolated from humans in Scotland (Scottish, Salmonella,<br />

Shigella and Clostridium difficile Reference Laboratory). All different<br />

serotypes got detected by the FTD Resp <strong>33</strong> test, with an equal efficiency<br />

(table7).<br />

March <strong>2011</strong>