12.07.2015 Views

Automatic Swing Door Operator DFA 127 Operating instructions E

Automatic Swing Door Operator DFA 127 Operating instructions E

Automatic Swing Door Operator DFA 127 Operating instructions E

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

ConfigurationsConfigurations of the <strong>DFA</strong> <strong>127</strong> can only be made with the electronic BDE-D. If atoggle switch is connected, a BDE-D must be connected briefly for the configuration.Further information for parameter changes can be taken from the user manual ofthe BDE-D (no. 903 109 271).Please always leave the configuration review sheet in the drive!6.2 Parameter descriptionParameter SettingrangeDRIVING CYCLEClosing speed 0 - 40(5 – 20 s)Opening speed 0 - 40(3 - 20 s)TIME DELAYOPENTime delay open 0 - 40(0 - 60 s)Time delay SSK 0 – 40(0 - 60 s)FactorydefaultDescription18 Slider control with 40 steps36 Slider control with 40 steps2 Effective with AKA, AKI and push toactuate0 - 20: Steps of 1 s21 - 40: Steps of 2 s4 Effective with SSK0 - 20: Steps of 1 s21 - 40: Steps of 2 sDRIVEOpening angle 0 - 40 35 The opening angle is estimated duringthe calibration run and is equivalentto the value of 40.6.3 Different factory defaults for door types Low EnergyParameterFactorydefaultParameterFactorydefaultDRIVING CYCLEClosing speed 10 Opening speed 20<strong>Operating</strong> <strong>instructions</strong> <strong>DFA</strong> <strong>127</strong> Full Power Rev. B 11/2006 Page 13 of 20

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!