Order specificationsMULTICAL ® 601 Type 67- Sensor connectionPt500 2-wire (T1-T2) CTop moduleNo module 0RTC (Real Time Clock) 1RTC + PQ or ∆t-limiter + hourly data logger 3RTC + data output + hourly data logger 5RTC + M-Bus 7RTC + 2 pulse outputs for energy + volume + hourly data logger 8RTC + 2 pulse outputs for CE and CV + program data loggerBBase moduleNo module 00<strong>Data</strong> + pulse inputs 10M-Bus + pulse inputs 20RadioRouter + pulse inputs 21Prog. data logger + RTC + 4…20 mA inputs + pulse inputs 220/4…20 mA outputs 23LonWorks, FTT-10A + pulse inputs 24Radio + pulse inputs (internal antenna) 25Radio + pulse inputs (external antenna connection) 26SupplyNo supply 0Battery, D-cell 2230 VAC supply module w/transformer 724 VAC supply module w/transformer 8Pt500 sensor setNo sensor set 0Pocket sensor set w/1.5 m cableAPocket sensor set w/3.0 m cableBPocket sensor set w/5 m cableCPocket sensor set w/10 m cableDShort direct sensor set w/1.5 m cableFShort direct sensor set w/3.0 m cableGFlow sensor/pick-up unitSupplied w/1 ULTRAFLOW ® (Please specify type) 1Meter typeCooling meter 5Country code (language on label etc.)XXWhen placing orders please state ULTRAFLOW ® type numbers separately.Kamstrup <strong>Metering</strong> Solutions8MULTICAL ® 601 & ULTRAFLOW ® <strong>14</strong> Cooling5810615_J1_GB_09.2009


AccessoriesCalculatorDescriptiontype No.D-cell battery 66-00-200-100<strong>Data</strong> cable w/USB plug 66-99-098Infrared optical reading head w/USB plug 66-99-099Infrared optical reading head w/D-sub 9F 66-99-102<strong>Data</strong> cable RS 232, D-sub 9F 66-99-106Verification unit (used with METERTOOL) 66-99-397/-398/-399USB to serial converter 59-20-<strong>14</strong>7METERTOOL for MULTICAL ® 601 66-99-704METERTOOL LogView for MULTICAL ® 601 66-99-705Temperatur sensorsDescriptiontype No.Change-over nipple M10 - R½ for direct short temperature sensor 65-56-491Change-over nipple M10 - R¾ for direct short temperature sensor 65-56-492Sensor pocket, length = 65 mm 65-57-324Sensor pocket, length = 90 mm 65-57-327Sensor pocket, length = <strong>14</strong>0 mm 65-57-3<strong>14</strong>Flow sensorsGlands including gaskets (PN16)Size Nipple Union Type No. 2 pcs.DN15 R½ G¾ - 6561-323DN20 R¾ G1 - 6561-324DN25 R1 G5/4 6561-325 -DN32 R5/4 G1½ 6561-3<strong>14</strong> -DN40 R1½ G2 6561-315 -Gaskets for flange meters (PN25)SizeType No.DN20 2210-<strong>14</strong>7DN25 2210-133DN40 2210-132DN50 2210-099DN65 2210-<strong>14</strong>1DN80 2210-<strong>14</strong>0DN100 1150-<strong>14</strong>2Gaskets for glandsSize (union)Type No.G¾ 2210-061G1 2210-062G5/4 2210-063G½ 2210-064G2 2210-065Please contact Kamstrup A/S for questions concerning further accessories.Kamstrup <strong>Metering</strong> Solutions10MULTICAL ® 601 & ULTRAFLOW ® <strong>14</strong> Cooling5810615_J1_GB_09.2009


Dimensional sketches flow sensorsULTRAFLOW ® <strong>14</strong>, DN20 to DN50Flange EN 1092, type B, PN25Nom. L M H2 B1 D H k Bolts App. weightdia. No. Thread d 2[kg]DN25 260 L/2 89 58 115 106 85 4 M12 <strong>14</strong> 5.0DN40 300 L/2 89


Installation of calculatorFront, verticalFront, at an anglebetween horizontal andverticalFront, horizontalInstallation example with suspensionNote! Cables must be installed from below.Installation of temperature sensorsNote: The suspension must not be used on condensing pipes.Suspension kit item no. 5915-<strong>14</strong>4. Not includedTemperature sensors must be mounted from belowKamstrup <strong>Metering</strong> Solutions<strong>14</strong>MULTICAL ® 601 & ULTRAFLOW ® <strong>14</strong> Cooling5810615_J1_GB_09.2009


Mounting of flow sensorsBefore mounting the flow sensor, flush the system thoroughlyand remove protection plugs/plastic membranes from theflow sensor. Correct flow sensor position (flow or return pipe)appears from the front label placed on the MULTICAL ® 601.The flow direction is indicated by an arrow on the side of theflow sensor.Glands and gaskets must be mounted as shown on thedrawing below.Straight inlet: ULTRAFLOW ® <strong>14</strong> requires neither straightinlet nor outlet to meet the Measuring Instruments Directive(MID) 2004/22/EC, OIML R75:2002 and EN <strong>14</strong>34:2007. Onlyin case of heavy flow disturbances before the meter will astraight inlet section be necessary. We recommend to followthe guidelines in CEN CR 13582.To prevent cavitation, the operating pressure at theULTRAFLOW ® <strong>14</strong> must be min. 1.5 bar at q pand min. 2.5 barat q s.ULTRAFLOW ® <strong>14</strong> must not be exposed to pressures belowambient pressure (vacuum).GasketGasketTorgue approx. 4 NmKamstrup <strong>Metering</strong> Solutions15MULTICAL ® 601 & ULTRAFLOW ® <strong>14</strong> Cooling5810615_J1_GB_09.2009


Mounting of ULTRAFLOW ® <strong>14</strong>ULTRAFLOW ® <strong>14</strong> must be mounted vertically, horizontally orat any angle in between.ULTRAFLOW ® <strong>14</strong> may be turned up to 45° in relation tohorizontal.The ULTRAFLOW ® <strong>14</strong> housing must not be mounted facingupwards or downwards.Kamstrup <strong>Metering</strong> Solutions16MULTICAL ® 601 & ULTRAFLOW ® <strong>14</strong> Cooling5810615_J1_GB_09.2009