12.07.2015 Views

PFMV - SMC

PFMV - SMC

PFMV - SMC

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Series <strong>PFMV</strong>5Specific Product Precautions 2Be sure to read before handling.Refer to front matters 58 and 59 for Safety Instructions and pages 892 to 896 forFlow Switch Precautions.CautionMounting8. Apply a wrench only to the designated partwhen installing the flow sensor in the systempiping.Tightening torque for fitting part:1 to 1.5 N·m9. When sensors are mounted as a manifold,pay attention to the dimensions of the connectedfittings.If the dimensions of the fittings are larger than those of sensors,they will be interfered with each other and the sensors cannotbe mounted properly.WarningWiring1. Verify the color and the terminal numberwhen wiring.Incorrect wiring can cause the sensor to be damaged and malfunction.Verify the color and the terminal number in the instructionmanual when wiring.2. Use caution not to repeatedly apply excessivebending or stretching forces to the leadwire.Repeated pulling or bending of the lead wire may cause someof the wires to break.3. Confirm proper insulation of wiring.Make sure that there is no faulty wiring insulation (contact withother circuits, ground fault, improper insulation between terminals,etc.). Damage may occur due to excess current flow into asensor.4. Do not connect wiring while energizing theproduct.The sensor and any equipment connected to it could break andmalfunction.WarningOperating Environment1. Never use in the presence of explosive gases.The sensor does not have an explosion proof construction. If itis used in an environment where explosive gases are used, itmay cause an explosive disaster. Therefore, never use it insuch an environment.2. Mount the sensor in a location where there isno vibration or no impact.The sensor output may change because the sensor and connectingpiping move.3. Fix the sensor and connecting piping.The sensor output may change because the sensor and connectedpiping move.4. Do not use in an area where surges are generated.When there are units that generate a large amount of surge inthe area around a sensor, (e.g., solenoid type lifters, high frequencyinduction furnaces, motors, etc.) this may cause deteriorationor damage to the sensor’s internal circuitry. Avoid sourcesof surge generation and crossed lines.5. Sensors are not equipped with surge protectionagainst lightning.The flow sensors are CE compliant; however, they are notequipped with surge protection against lightning. Lightningsurge protection measures should be applied directly to systemcomponents as necessary.6. Avoid using the sensor in an environmentwhere the likelihood of splashing or sprayingof liquids exists.The sensor is an open type and should not be used in an environmentexposed to splashing of water and oil.7. Do not use the product in an environmentsubject to a temperature cycle.If the product is subject to a temperature cycle other than naturalchanges in air temperature, the internal components of thesensor could be adversely affected.8. Do not mount the product in locations whereit is exposed to radiant heat.This could result in damage and/or malfunction.964

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!