5-7 S-METER ADJUSTMENT (continued)1) Select an adjustment item using [VFO/MHz] / [M/CALL].2) Set the SSG as specifi ed (frequency and output level).3) Push [BAND] to adjust (automatic) and store the adjustment value.ADJUSTMENTADJUSTMENTOPERATIONVALUEITEM(Full scale)20 • Set the SSG as;[UHF band 3] (FM)[SF5]Frequency : (Displayed on the function display)Level : +12 dBµ (–95 dBm) † Push [BAND].(Automatic(Full scale)21 • Set the SSG as;adjustment)[UHF band 3] (FMN) [SF5]Frequency : (Displayed on the function display)Level : +12 dBµ (–95 dBm) †† ; This output level of a standard signal generator (SSG) is indicated as SSG’s open circuit.5-8 SQUELCH ADJUSTMENT1) Select an adjustment item using [VFO/MHz] / [M/CALL].2) Push [BAND] to adjust (automatic) and store the adjustment value.ADJUSTMENTADJUSTMENTOPERATIONITEMSQUELCH1 • Connect a terminator to the antenna connector.[SQ1][VHF band 1] (FM)[VHF band 1] (FMN) [SQ1] 2[VHF band 2] (FM) [SQ2] 3[VHF band 2] (FMN) [SQ2] 4[UHF band 1] (FM) [SQ3] 5[UHF band 1] (FMN) [SQ3] 6[UHF band 2] (FM) [SQ4] 7[UHF band 2] (FMN) [SQ4] 8[UHF band 3] (FM) [SQ5] 9[UHF band 3] (FMN) [SQ5] 10VALUEPush [BAND].(Automaticadjustment)5 - 9