12.07.2015 Views

Life Science

Life Science

Life Science

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Report #UCR P5316 <strong>Life</strong> <strong>Science</strong> BuildingReportNameItem/LocationBarrier(noted feature, item or area does not meet thenew construction criteria detailed below)Action Priority TargetDateEstimatedCostInterimSolutionActionCompletionDateUCR P5316 111-Signage: Room<strong>Life</strong> #2705 at the West Wing<strong>Science</strong> on the 2nd Floor of <strong>Life</strong>Building <strong>Science</strong>s.UCR P5316<strong>Life</strong><strong>Science</strong>Building115-Water Fountains(Drinking): West Wingon the 2nd Floor of <strong>Life</strong><strong>Science</strong>s.Signage for Permanent Rooms and Spaces:Letters are 1/32" raised, uppercase or sans serifw/ Grade II Braille.32" minimum wide and 18" minimum deepalcove provided. 18" - 19" depth of fountain. 27"high x 8" deep clear knee space under fountain.Bubbler outlet is 36" maximum from floor.Stream of bubbler is parallel to front edge.Install permanent ID sign tolatch side of door.Install new single drinkingfountain. Install canedetectablebarrier aroundfountain.1 $183.752 $6,640.81 Defer.UCR P5316<strong>Life</strong><strong>Science</strong>BuildingUCR P5316<strong>Life</strong><strong>Science</strong>BuildingUCR P5316<strong>Life</strong><strong>Science</strong>BuildingUCR P5316<strong>Life</strong><strong>Science</strong>Building116-Doors: Rooms#2710, #2715, #2720,#2725, #2730, #2735,#2740, #2745, #2805and #2840 on the 2ndFloor West Wing of <strong>Life</strong><strong>Science</strong>s.118-Signage: Rooms#2710, #2715, #2720,#2725, #2730, #2735,#2740, #2745, #2805and #2840 on the 2ndFloor West Wing of <strong>Life</strong><strong>Science</strong>s.119-Tactile ExitSignage: Stairs at theWest Wing on the 2ndFloor of <strong>Life</strong> <strong>Science</strong>s.120-Doors: West WingEntrance to <strong>Life</strong><strong>Science</strong>s Psychology onthe 1st Floor. [One set ofdouble doors.]Door hardware is operable with a single effort(lever type, panic bar or push pull type).Signage for Permanent Rooms and Spaces:Letters are 1/32" raised, uppercase or sans serifw/ Grade II Braille.Each exit door that leads directly to a gradelevelexterior exit by means of a stairway orramp is identified by a tactile exit sign that states"EXIT STAIR DOWN", "EXIT RAMP DOWN","EXIT STAIR UP", or "EXIT RAMP UP", asappropriate.1/4" maximum vertical threshold or 1/2" beveledat 1:2. 5 lb. maximum pressure to operateexterior doors. 3 seconds minimum for doorcloser to close from 70 degree position to within3" of the latch [ADAAG 404.2.8.1 Door & gateclosers require a 5 second minimum closingtime from open position of 90 degree to 12degree position]. The international symbol ofaccessibility is posted at all primary entrances.Replace door hardware withcompliant hardware.Install permanent ID sign tolatch side of door.1 $4,777.571 $1,837.54Provide compliant sign. 1 $183.75Replace or modify thethreshold. Adjust door openingpressure / closing time unlessaccepted by DSA Fire / <strong>Life</strong>Safety. Consider issuesconnected with buildingpressure / climate control. Posta sign/decal displaying the"International Symbol ofAccessibility" at the primaryentrance.1 $575.776/1/2012 Page 18 of 32

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!