12.07.2015 Views

Life Science

Life Science

Life Science

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Report #UCR P5316 <strong>Life</strong> <strong>Science</strong> BuildingReportNameItem/LocationBarrier(noted feature, item or area does not meet thenew construction criteria detailed below)Action Priority TargetDateEstimatedCostInterimSolutionActionCompletionDateUCR P5316 3-Signage: North 1st<strong>Life</strong> Floor Entry at <strong>Life</strong><strong>Science</strong> <strong>Science</strong> Building.BuildingUCR P5316 4-Tactile Exit Signage:<strong>Life</strong> North 1st Floor Entry at<strong>Science</strong> <strong>Life</strong> <strong>Science</strong> Building.BuildingUCR P5316 5-Floors and Levels: <strong>Life</strong><strong>Life</strong> <strong>Science</strong> Psychology<strong>Science</strong> North Entrance Door.BuildingUCR P5316<strong>Life</strong><strong>Science</strong>Building7-Electrical Controls &Receptacles/Fire AlarmBoxes: North to SouthCorridor on 1st Floor of<strong>Life</strong> <strong>Science</strong>.Signage for Permanent Rooms and Spaces:Letters are 1/32" raised, uppercase or sans serifw/ Grade II Braille.Each grade-level exterior exit door shall beidentified by a tactile sign with the word "EXIT".Carpets or carpet tiles are securely attachedand do not exceed 1/2" in height. Carpet'sexposed edges are fastened to floor surfacesand have trim along entire length.The center of electrical outlets intended to beused by the room occupant are located a min. of15" above the floor or working platform. Theheight of the manual fire alarm box is a minimumof 42" and a maximum of 48", measuredvertically, from the floor level to the highest pointof the activating handle or lever of the box.Install permanent ID sign tolatch side of door.1 $183.75Provide compliant sign. 1 $183.75Secure loose doormat. 1 $245.01Relocate electrical receptacle.Relocate fire alarm initiatingdevice.1 $4,747.55UCR P5316 8-Visual/Audible Alarms:<strong>Life</strong> North to South Corridor<strong>Science</strong> on 1st Floor of <strong>Life</strong>Building <strong>Science</strong>.UCR P5316<strong>Life</strong><strong>Science</strong>BuildingUCR P5316<strong>Life</strong><strong>Science</strong>Building9-Hazards: North toSouth Corridor on 1stFloor of <strong>Life</strong> <strong>Science</strong>.[One clock.]10-Doors: WestEntrance to <strong>Life</strong><strong>Science</strong>s Psychology.[One set of doubledoors.]The appliance is placed 80" above the highestfloor level within the space or 6" below theceiling, whichever is lower.Any obstrution that overhangs a pedestrian wayis a minimum 80" above the walking surface(measured from the bottom of the obstruction).Sidewalks are clear of hazards. If verticalclearance of an area adjoining an accessibleroute is reduced to less than 80", a barrier towarn blind or visually impaired persons isprovided.5 lb. maximum pressure to operate exteriordoors. The international symbol of accessibilityis posted at all primary entrances.Review the entire alarmsystem.Install cane detectable barrierbelow clock.Provide a sign/decal displayingthe international symbol ofaccessibility.Adjust dooropening pressure / closing timeunless accepted by DSA Fire /<strong>Life</strong> Safety. Consider issuesconnected with buildingpressure / climate control.1 $7,115.621 $122.511 $330.766/1/2012 Page 1 of 32

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!