User ManualFor connection to the <strong>S7</strong> DP master, a 9-way subminiature D connector is required (eg, SINEC L2 busconnector SIEMENS 6E<strong>S7</strong>972-0BA10-0XA0).Switch position = OffTerminating resistor disconnectedOffB A B AB = RS485P = pin 3A = RS485N = pin 8The cable shield (12mm)must be bare <strong>and</strong> contactthe metal guideBus cable from Bus cable toone nodethe next nodeBus interface on MASTERDRIVES with CBP9-way subminiature D connector X448 (use SINEC L2 bus connector as <strong>for</strong> <strong>SIMATIC</strong> <strong>S7</strong>, see above)X448Assignment123 B line, receive/transmit data P45678 A line, receive/transmit data N9Terminate the bus (only necessary if the drive is the first or last node):Via switch in SINEC L2 bus connector.6.2 Parameterization of the DP interfaceThe DP interface is parameterized during hardware configuration in STEP7. Be<strong>for</strong>e configuring the hardwareyou must install the DVA_<strong>S7</strong> object manager <strong>for</strong> drives as an add-on to STEP 7. Otherwise DPV1communication is not possible!When you select a CPU with integrated DP interface from the hardware catalog of STEP 7, a PROFIBUS-DPsystem is provided in the hardware configuration. Once the parameters of the master (eg, baud rate) havebeen set, the slaves must be selected from the hardware catalog <strong>and</strong> placed in the PROFIBUS line(PROFIBUS-DPà MASTERDRIVES CBP à Vector Control CU2)Only the station number has to be parameterized <strong>for</strong> the slaves. It does not matter which PPO type is used <strong>for</strong>DPV1 communication.The DP system is now parameterized <strong>for</strong> the program example <strong>and</strong> the data <strong>for</strong> the hardware configuration canbe loaded in the CPU.6.3 PLC programThe example program from library path EXAMPLE<strong>300</strong>+<strong>400</strong> can be loaded directly into the CPU memory.© Siemens AG 1998 All Rights Reserved <strong>SIMATIC</strong> <strong>S7</strong> PROFIBUS-DP <strong>Functions</strong>18 E20125-C0011-S302-A2-7600

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!