12.07.2015 Views

potted history of rayburn solid fuel cookers post - Harworth Heating Ltd

potted history of rayburn solid fuel cookers post - Harworth Heating Ltd

potted history of rayburn solid fuel cookers post - Harworth Heating Ltd

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

THE SUPREMEwhich also altered the oven temperature byallowing more or less air to the fire grate.Available in a limited range <strong>of</strong> colours, it had abrown top-plate and enamelled lids and wasalso available in a Matt-finish black or brownenamel, the latter with brass colour fittings.Manufacture had ceased by 1992, beingreplaced by the Nouvelle, which had beenintroduced in the mid 1980's.RAYBURN SOLID FUEL NOUVELLERayburn 300W, 345W, 355S, 355M &355SFWThe Rayburn Supreme was introducedin 1982 for use with a range <strong>of</strong> <strong>solid</strong> <strong>fuel</strong>s andalso wood and peat. It provided cookingtogether with domestic hot water and heating.It was only produced with ovens on the righthand side.The fabricated steel boiler was originallyquoted as providing 35000BTU/Hr (10.3KW),based on a 4 hour re-<strong>fuel</strong>ling cycle, inaccordance with B.S. 1252. This was achievedby maintaining a high oven temperature andselecting the 'heating' position on the controldamper. The output figure reduced to20000BTU/Hr (5.8KW) when burning wood.During summer use when the firebrickpositions were changed, the output reduced to3.1KW (for <strong>solid</strong> <strong>fuel</strong> use) with the 'cooking'position <strong>of</strong> the control damper selected. Theboiler temperature was controlled using thethermostat sited at the rear <strong>of</strong> top plate.The appliance was fitted to a heating systemwith the circulating pump on the return pipebefore the junction <strong>of</strong> the return from theindirect cylinder. The domestic hot water isavailable constantly, while the appliance isalight, by using an open vented gravity feed190 Litre (40 gallon) cylinder. The pump canbe controlled by a programmer and/or roomthermostat, and it was recommended that aboiler low temperature return thermostat befitted.The hotplate had 2 hinged insulating lids, theheat being provided by the hot flue gasespassing across the underside. The temperaturebeing regulated by use <strong>of</strong> the spin wheel,The Rayburn Solid <strong>fuel</strong> Nouvelle wasintroduced in the mid 1980's, to initiate a newrange <strong>of</strong> central-heating <strong>cookers</strong> intended foruse with a range <strong>of</strong> <strong>solid</strong> <strong>fuel</strong>s and also woodand peat. Oil & Gas Nouvelle's weresubsequently introduced.Similar to the Rayburn Supreme, the Nouvelle<strong>of</strong>fered wider choice <strong>of</strong> colour options andchrome insulating covers.It provided cooking together with domestic hotwater and heating. It was only produced withovens on the right hand side.Advantage was taken to quote the boileroutput ratings in accordance with the newEuropean Standards, which permitted a 2 hourre-<strong>fuel</strong>ling cycle. Therefore, although thefabricated steel boiler was identical to theRayburn Supreme model, it was quoted ashaving the higher maximum output <strong>of</strong>16.1kw/hr (coal) 5.9kW/hr for wood. This was4

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!