12.07.2015 Views

InTrac 797 – the original retractable housing for ... - Mettler Toledo

InTrac 797 – the original retractable housing for ... - Mettler Toledo

InTrac 797 – the original retractable housing for ... - Mettler Toledo

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Retractable <strong>housing</strong>s <strong>InTrac</strong> <strong>797</strong><strong>InTrac</strong> <strong>797</strong> – <strong>the</strong> <strong>original</strong> <strong>retractable</strong> <strong>housing</strong> <strong>for</strong>sterilization of sensors in biotech processes.The <strong>InTrac</strong> <strong>797</strong> is a state-of-<strong>the</strong>art<strong>retractable</strong> <strong>housing</strong> specificallydesigned <strong>for</strong> on-line measuringapplications in <strong>the</strong> biotechnologyindustry.It enables safe insertion and withdrawalof sensors during an ongoingprocess without compromisingsterility.– Twin chamber lock enables easyelectrode/sensor maintenance orreplacement and steam-sterilizationin-situ, without process interruptionor compromise on sterility– Enhanced safety in combinationwith safety weld-in socket– Side-mounting in bioreactors andvessels through 25 mm standard(Ingold) or safety weld-in sockets– Suited <strong>for</strong> low-maintenance, gelfilledpH and redox electrodes, aswell as 12mm DO sensors– Versions <strong>for</strong> manual or pneumaticoperation– Pressure resistant up to 6 bar,allowing application in largescaleindustrial fermenters andprocess vessels<strong>InTrac</strong> <strong>797</strong> is designed to meet <strong>the</strong>specific application requirements ofbiotechnology processes.


Retractable <strong>housing</strong>s <strong>InTrac</strong> <strong>797</strong>∅ 50∅ 50∅ 50R1 1/4"∅ 25a = 32543H = 751 «OUT» position approx. 4652 approx. 4853 «IN» position approx. 41712 3Retractable <strong>housing</strong> <strong>for</strong> use in biotech.The electrode or sensor can be sterilized inside <strong>the</strong> <strong>housing</strong> when in retracted position, using<strong>the</strong> controlled environment of <strong>the</strong> twin-chamber lock. This double lock effectively protects <strong>the</strong>process from any intrusion of contamination after insertion of <strong>the</strong> electrode/ sensor. The <strong>housing</strong>also enables <strong>the</strong> electrode/sensor to be withdrawn from <strong>the</strong> process <strong>for</strong> maintenance purposesunder sterile conditions while <strong>the</strong> process is still running. After servicing or exchange,<strong>the</strong> electrode/ sensor can be steam-sterilized within <strong>the</strong> <strong>housing</strong> be<strong>for</strong>e reinsertion into <strong>the</strong>process medium, without any fear of contamination.The <strong>InTrac</strong> <strong>797</strong> is easily installed through <strong>the</strong> side of <strong>the</strong> reactor or vessel, using a 25 mmweld-in socket (Ingold type or METTLER TOLEDO safety socket). It is available ei<strong>the</strong>r as amanually operated version or with pneumatic drive.SpecificationsPressure in reactor:Temperature rangesRetractable member:Headpart:Weld-in socket:Insertion length:MaterialsProcess wetted:Headpart:Seals process wetted:O<strong>the</strong>r seals:Flushing connections:<strong>InTrac</strong> <strong>797</strong>-M/75, <strong>InTrac</strong> <strong>797</strong>-P/75, <strong>InTrac</strong> <strong>797</strong>-M/75 FSCdependant on sensor specification, but not more <strong>the</strong>n 6 bar0...130°C, steam-sterilizable0...80°CID = 25 mm, L = 40 mm, 15° chamferH = 75 mmStainless steel, DIN 1.4435 with 3.1b material certificatePOM (polyoxymethylene) and PP (polypropylene)Viton ® FDANitrile, BunaG 1 ⁄ 8 " threadINTERNEThttp://www.mtpro.comOrdering In<strong>for</strong>mationDesignationOrder no.<strong>InTrac</strong> <strong>797</strong>-M/75 (manual) 00 <strong>797</strong> 3007<strong>InTrac</strong> <strong>797</strong>-P/75 (pneumatic) 00 <strong>797</strong> 3009<strong>InTrac</strong> <strong>797</strong>-M/75 FSC (<strong>for</strong> turbidity measurements) 00 <strong>797</strong> 3012(Fitting sets <strong>for</strong> steam lines see «spare parts and accessories»)Standard-ElectrodesThe recommended gel-filled electrodes require little maintenance, because <strong>the</strong> electrolyte does not need to be refilled.Designation Order no. Designation Order no.pH electrode: InPro 3030/325 52 001 316 O 2 sensor InPro 6100/320/T/N 52 200 102pH electrode: 405-DPAS-SC-K8S/325 10 405 4482 O 2 sensor InPro 6100/320/S/N 52 200 118Redox el.: Pt4805-DPAS-SC-K8S/325 10 505 3337 O 2 sensor InPro 6100/320/T/P 52 200 110Turbidity sensor: OFS12S-297I 00 824 500 O 2 sensor InPro 6100/320/S/P 52 200 126For <strong>the</strong> <strong>retractable</strong> installation of liquid-filled electrodes we recommend <strong>the</strong> <strong>InTrac</strong> 796 <strong>housing</strong>.Spare parts and accessoriesDescriptionOrder no.Service kit, small 00 <strong>797</strong> 2003Service kit, large 00 <strong>797</strong> 2002Weld-in socket, inclined 15°, L = 40 mm, stainless steel DIN 1.4435 00 764 1014Safety weld-in socket, inclined 15°, L = 40 mm, stainless steel DIN 1.4435 52 400 462Fitting set <strong>for</strong> <strong>InTrac</strong> 796/<strong>797</strong> Serto, Material: 1.4571 00 <strong>797</strong> 2006Fitting set <strong>for</strong> <strong>InTrac</strong> 796/<strong>797</strong> Gyrolok, Material: 1.4401 00 <strong>797</strong> 2008Fitting set <strong>for</strong> <strong>InTrac</strong> 796/<strong>797</strong> Swagelok, Material: 1.4401 00 <strong>797</strong> 2007Conversion kit, manual to pneumatic operation 00 777 2004Gasket 20 305 1004Temperature sensor Pt100-764/5m 10 100 3104Sales and service:ISO9001certifiedISO14001certifiedThe <strong>retractable</strong> <strong>housing</strong> <strong>InTrac</strong> <strong>797</strong> toge<strong>the</strong>r with <strong>the</strong> appropriate electrode or sensor and atransmitter from METTLER TOLEDO offers a complete system <strong>for</strong> <strong>the</strong> accurate and reproduciblemeasurement of pH, redox, dissolved oxygen or turbidity values in biotechnology.Management Systemcertified according toISO 9001 / ISO 14001<strong>Mettler</strong>-<strong>Toledo</strong> GmbH, Process Analytics,Industrie Nord, CH-8902 Urdorf,Phone +41-1-736 22 11, Fax +41-1-736 26 36Subject to technical changes.© <strong>Mettler</strong>-<strong>Toledo</strong> GmbH 04/00Printed in Switzerland. 52 400 081

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!