12.07.2015 Views

MiniMax® NT Series - H2Oco.com

MiniMax® NT Series - H2Oco.com

MiniMax® NT Series - H2Oco.com

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Section III.Installation11GAS CONNECTIONSGAS LINE INSTALLATIONSBefore installing the gas line, be sure to check which gas the heater has been designed to burn. This isimportant because different types of gas require different gas pipe sizes. The rating plate on the heater willindicate which gas the heater is designed to burn. The tables, shown on page 12, show which size pipe isrequired for the distance from the gas meter to the heater. The table is for natural gas at a specific gravityof .65 and propane at a specific gravity of 1.55.When sizing gas lines, calculate three (3) additional feet of straight pipe for every elbow used. Wheninstalling the gas line, avoid getting dirt, grease or other foreign material in the pipe as this may causedamage to the gas valve, which may result in heater failure.The gas meter should be checked to make sure that it will supply enough gas to the heater and any otherappliances that may be used on the same meter. The gas line from the meter will usually be of a larger sizethan the gas valve supplied with the heater. Therefore a reduction of the connecting gas pipe will benecessary. Make this reduction as close to the heater as possible.The heater and any other gas appliances must be disconnected from the gas supply piping system during anypressure testing on that system, (greater that ½ PSI). The heater and its gas connection must be leak testedbefore placing the heater in operation. Do not use flame to test the gas line. Use soapy water or anothernonflammable method.NOTEA manual main shut-off valve must be installed externally to the heater.WARNINGDO NOT INSTALL THE GAS LINE UNION INSIDE THE HEATER CABINET. THIS WILL VOID YOUR WARRA<strong>NT</strong>Y.SEDIME<strong>NT</strong> TRAPSInstall a sediment in front ofthe gas controls. The sedimenttrap shall be either a tee fittingwith a capped nipple in thebottom outlet which can beremoved for cleaning, asillustrated in Figure 3, or aother device recognized as aneffective sediment trap. Allgas piping should be testedafter installation in accordancewith local codes.GASSUPPLYMANUALSHUT OFFVALVENIPPLECAPUNIO<strong>NT</strong>EEFITTING3 INCHESMINIMUMGASVALVEHEATER CABINETFigure 3.Rev. D 12-22-04 P/N 472235

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!