If it is found that there is excessive draught in the chimney then either an adjustableflue damper or alternatively a draught stabiliser should be fitted. The adjustable fluedamper should not close off the flue entirely, but should in its closed position leave aminimum continuous opening free area of at least 20 % of the total cross sectionalarea of the flue or fluepipe.Adequate provision e.g. easily accessible soot door or doors must be provided <strong>for</strong>sweeping the chimney <strong>and</strong> connecting fluepipe.You should also familiarise yourself with the draught conditions <strong>for</strong> chimneys with 2flues.For strong draughts, the chimney or flue should be fitted with a draught stabiliser. Inwhich case, it is important to ensure that there is a free flow­through area of minimum20 cm 2 when the regulating gate is shut. Otherwise, the fuel energy may not be <strong>use</strong>doptimally.If, at any time, you are unsure about the condition of the chimney, you should contacta chimney sweep.Remember that access to the soot door should be kept clear.