Central venous<br />
catheter<br />
PiCCO plus Setup<br />
Injectate-temperature<br />
sensor cable<br />
PC80109<br />
Temperature-interface<br />
cable PC80150<br />
PULSIOCATH Arterial<br />
Thermodilution Catheter<br />
e.g. PV2015L20<br />
Injectate-temperature<br />
sensor housing PV4046<br />
(included PV8115)<br />
Pressure cable<br />
PMK-206<br />
<strong>PULSION</strong> <strong>Medical</strong> <strong>Systems</strong> AG • Joseph-Wild-Str. 20 • D-81829 Munich, Germany<br />
Tel. +49-(0)89-45 99 14-0 • Fax +49-(0)89-45 99 14-18 • info@pulsion.com • www.<strong>PULSION</strong>.com<br />
AUX Adapter cable<br />
PC81200<br />
<strong>PULSION</strong> disposable pressure transducer<br />
PiCCO Monitoring Kit PV8115<br />
PMK-XXX<br />
Connecting-cable<br />
to bedside monitor
02<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
Choose Yes for a new patient, old data will be<br />
deleted, modify with<br />
Confirm with<br />
Enter patient ID number, height and weight<br />
of the patient<br />
For safety reasons, change of the ID number<br />
will delete stored data<br />
Arterial catheter will be detected automatically<br />
The minimal required injectate volume is<br />
given in ( )<br />
15 ml iced NaCl 0,9% as the default setting<br />
for adult patients<br />
Enter CVP<br />
PiCCO plus Patient Admission<br />
Upper / lower limit of the display range of PCCO<br />
Upper / lower warning limits for range of PCCO<br />
1<br />
03<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
Open transducer to<br />
the atmosphere<br />
Press zero button<br />
Perform Zero Adjustment first<br />
on PiCCO plus then on bedside<br />
monitor<br />
Confirm with<br />
After pressing AP Correction Screen<br />
appears, default setting should be .<br />
(Difference in level of pressure transducer and<br />
patients heart can be corrected.)<br />
Thermodilution Screen<br />
Configuration Screen<br />
Input Screen<br />
Pulse-Contour Screen<br />
Pressure-Zeroing Screen<br />
PiCCO plus Zero Adjustment<br />
1 2<br />
3<br />
4 5 6 7 8
04<br />
Dräger Infinity ® PiCCO SmartPod PiCCO plus Configuration<br />
*For safety reasons, modification of date or time will delete patient related data<br />
Press to Configuration Screen and choose to access the Configure<br />
Display and select the most important PiCCO parameters<br />
Basic setup: Can not be changed and displays most common parameters as default<br />
Individual: User can configure own parameter selection
05<br />
1<br />
2<br />
3<br />
Press to Thermodilution Screen<br />
Press to perform a measurement<br />
Wait until appears<br />
PiCCO plus Thermodilution<br />
Perform a rapid and smooth injection<br />
3<br />
2<br />
1
06<br />
1<br />
2<br />
PiCCO plus Thermodilution II<br />
Press for further measurements<br />
Perform initially 3 thermodilution measurements<br />
In case of ELWI >10ml/kg it is recommended to<br />
use iced injectate for further measurements<br />
**If ΔT < 0,15°C, it may be necessary to use more<br />
and / or colder injectate.<br />
Select “injectate temperature
07<br />
1<br />
PiCCO plus Calibrate<br />
Deviating measurements should be selected with and , confirm<br />
by pressing once. Selected Thermodilution Curve is displayed.<br />
To delete this measurement press again<br />
It is only possible to delete the current measurements under the dashed line<br />
The mean results of the Thermodilution measurements of the last 10 minutes<br />
automatically calibrate the continuous cardiac output<br />
1
08<br />
1<br />
2<br />
3<br />
4<br />
5<br />
CI = Cardiac Index<br />
GEF = Global Ejection Fraction<br />
*GEDI or ITBI = Global End-Diastolic Volume<br />
Index or Intrathoracic Blood Volume Index<br />
ELWI = Extravascular Lung Water Index<br />
PCCI = Pulse Contour Cardiac Index<br />
Continuous Cardiac Output<br />
SVV = Stroke Volume Variation<br />
Press to display arterial pressure curve<br />
The display range of PCCI can be changed in<br />
the Input Screen<br />
NB: Values can be displayed as either indexed<br />
or absolute values by pressing<br />
*parameter selection in<br />
PiCCO plus Parameters<br />
Thermodilution Continuous<br />
results results<br />
4<br />
5<br />
5<br />
1<br />
2<br />
3