12.07.2015 Views

Test Tools Catalog - Brink Techniek

Test Tools Catalog - Brink Techniek

Test Tools Catalog - Brink Techniek

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

1555 and 1550C InsulationResistance <strong>Test</strong>ersSpecificationsPowerful troubleshooting andpredictive maintenance toolsThe new Fluke 1555 and redesigned Fluke1550C insulation resistance testers offerdigital insulation testing up to 10 kV, makingthem ideal for testing a wide range ofhigh voltage equipment including switchgear,motors, generators and cables.• <strong>Test</strong> voltages up to 5 kV (1550C) and10 kV (1555) provide solutions for allapplications• Warning function alerts the user that linevoltage is present and gives a voltagereading up to 600 V ac or dc for increaseduser safety• Measurements can be stored in up to 99memory locations, and each location isassigned a unique, user-defined label foreasy recall• Long battery life gives the user over 750tests between changes• Automatic calculation of Dielectric Absorption(DAR) and Polarization Index (PI) withno additional setup• Guard system eliminates the effect of surfaceleakage current on high-resistancemeasurements• Large digital/analog LCD for easy viewing• Capacitance and leakage currentmeasurement• Ramp function for breakdown testing• Three-year warrantyApplication noteInsulation resistance testingInsulationresistancetesters canbe used todeterminethe integrityof windingsor cablesin motors,transformers,switch-gear,and electricalinstallations.The testmethod isdetermined by the type of equipmentbeing tested and the reason fortesting. For instance, when testingelectrical cabling or switchgear(low-capacitance equipment) thetime-dependent capacitive leakageand absorption leakage currentsbecome insignificant and decreaseto zero almost instantly. A steadyconductive leakage current flow isreached almost instantly (a minute orless) providing perfect conditions forthe spot-reading/short-time resistancetest.www.fluke.com/IRTThe tester’s accuracy is specified for one year after calibration at operating temperatures of 0 °C to 35 °C. For operating temperaturesoutside the range (-20 °C to 0 °C and 35 °C to 50 °C), add ± .25 % per °C, except on the 20 % bands add ± 1 % per °C.Insulation resistance measurement<strong>Test</strong> voltage (dc) Range Accuracy (± reading)250 V < 200 kΩ200 kΩ to 5 GΩ5 GΩ to 50 GΩ> 50 GΩ500 V < 200 kΩ200 kΩ to 10 GΩ10 GΩ to 100 GΩ> 100 GΩ1000 V < 200 kΩ200 kΩ to 20 GΩ20 GΩ to 200 GΩ> 200 GΩ2500 V < 200 kΩ200 kΩ to 50 GΩ50 GΩ to 500 GΩ> 500 GΩ5000 V < 200 kΩ200 kΩ to 100 GΩ100 GΩ to 1 TΩ> 1 TΩ10000 V (1555 Only) < 200 kΩ200 kΩ to 200 GΩ200 GΩ to 2 TΩ>2TΩunspecified5 %20 %unspecifiedunspecified5 %20 %unspecifiedunspecified5 %20 %unspecifiedunspecified5 %20 %unspecifiedunspecified5 %20 %unspecifiedunspecified5 %20 %unspecifiedRecommended kits1550C/Kit includes:• 1550C insulation resistance tester• Ruggedized alligator clips• IP67 hard case• NIST traceable certificate of calibration1555/Kit includes:• 1555 insulation resistance tester• Ruggedized alligator clips• IP67 hard case• NIST traceable certificate of calibrationFunctions Range Accuracy (± reading)Leakage current 1 nA to 2 mA ± (5 % + 2 nA)Capacitance measurement 0.01 uF to 15.00 µF ± (15 % rdg + 0.03 µF)Live circuit indicator 30 V to 600 V ac/dc, 50/60 Hz ± (5 % + 2 V)Ordering informationIncluded accessories<strong>Test</strong> leads with alligator clips, ruggedized alligator clips(kits and 1555 only), infrared adapter with interfacecable, FlukeView Forms software, ac power cord, softcarrying case, quick reference guide, users manual.ModelsFLUKE-1550CFLUKE-1550C/KitFLUKE-1555FLUKE-1555/Kit5 kV Insulation <strong>Test</strong>er5 kV Insulation <strong>Test</strong>er Kit10 kV Insulation <strong>Test</strong>er10 kV Insulation <strong>Test</strong>er KitCheck price and availability atwww.fluke.com/wtbFor more information, go to www.fluke.com/1550Insulation Resistance <strong>Test</strong>ing25

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!