Fluke 717, 718 and 719 Pressure CalibratorsAccurate and rugged, temperature calibration toolsPressureEnabledFluke 719SpecificationsFluke 719 Electric Pressure Calibrators• Electric pump enables one handed pressure pumping andmakes pressure calibration quicker and easier• Best in class 0.025 % pressure measurement accuracy• Programmable pump limit settings can eliminate overpressurization—set‘pump to’ pressure values• Two ranges, 30 PSI and 100 PSIFluke 718 Pressure Calibrators• 1, 30, 100 and 300 PSI ranges available• Pump to 300 PSI, 20 bar with internalpump (718-300G)• 718-1G includes special low volumepump and high measurement resolutionfor low pressure calibrationFluke 717 Pressure Calibrators• Measure up to 5000 PSI/345 bar sensor(5000G model)• Compatible with non-corrosive gasesand liquids718 and 719• Precision vernier for fine pressureadjustment• Variable release rate bleed valve forcontrolled pressure release717, 718 and 719 commonfeatures• Pressure switch test makes a difficulttask easy, captures set, reset and deadbandvalues of a pressure switch• 717 and 718, measure pressure to0.05 % of full scale with internal sensor• Measure mA with 0.015 % accuracyand 0.001 mA resolution, while sourcing24 V loop powerFluke 718Fluke 717Specialty modelFluke 700 Series Pressure Modules• 29 pressure modules• 8 intrinsically safepressure modules*• Ranges from1.000 in H 2 0(0.2491 kPa)to 10,000 psi(68.948 MPa)• Gage, differential,dual (compound),absolute, andvacuum modules• Rugged cases protect the modulesfrom harsh environments• Full-accuracy performance from0 °C to 50 °C*For use with 718Ex and 725Ex only(see page 39 for more information).PressureEnabledResourcesFluke Process Calibrators in this catalogdisplaying the Pressure Enabledsymbol display readings from the700 Series Pressure Modules.More info online atwww.fluke.com/processtoolsCheck out the 719 video atwww.fluke.com/719videoModels Range Resolution Comment717-1 +/- 1 psi, 27.5 in H 2 0, +0.0001 psi, 0.0001 kPa, Fluke-718 dry air only and includes on board718-1G717-30G(-7 - +7 kPa)0.0001 in H 2 0pump-12 to + 30 psi,0.001 psi, 0.001 kPa, 0.001 Fluke-718 and Fluke-719 dry air only and718-30G* and (-83 to 207 kPa)in H 2 0includes on board pump719-30G717-100G -12 to + 100 psi,Fluke-718 and Fluke-719 dry air only and0.01 psi, 0.01 kPa, 0.01 in H(-83 to 690 kPa)2 0718-100G*includes on board pump717-300G718-300G* and719-100G-12 to +300 psi,(-83 to +2070 kPa)Ordering information0.01 psi, 0.01 kPa, 0.01 in H 2 0Fluke-718 dry air only and includes on boardpump717-500G 0-500 psi, 0-3450 kPa 0.01 psi, 0.1 kPa Compatible with non-corrosive gases and fluids717-1000G 0-1000 psi, 0-6900 kPa 0.01 psi, 0.1 kPa Compatible with non-corrosive gases and fluids717-1500G 0-1500 psi, 0-10342 kPa 0.1 psi, 1 kPa Compatible with non-corrosive gases and fluids717-3000G 0-3000 psi, 0-20700 kPa 0.1 psi, 1 kPa Compatible with non-corrosive gases and fluids717-5000G 0-5000 psi, 0-34500 kPa 0.1 psi, 1 kPa Compatible with non-corrosive gases and fluidsPressure accuracy 0.05 % of range, one year for 717 and 718. 0.025 % for six months, 0.035 % of range, one year for the 719mA measurement 0-24 mA range 0.001 mA resolution Accuracy: ± 0.015 % + 1 countLoop power 24 V dc Accuracy: ± 10 %*Intrinsically safe models available, see page 39.Warranty: Three-year on calibrator, one-year on pump.Included accessories Models<strong>Test</strong> leads, alligator FLUKE-719-30G Electric Pressure Calibrator FLUKE-719-100G Electric Pressure Calibratorclips, holster, test hose(719), one 9 V alkalineFLUKE-718 1G Pressure Calibrator FLUKE-718 30US Pressure Calibratorbattery (two 9 V batteriesFLUKE-718 100US Pressure Calibrator FLUKE-718 300G Pressure Calibratorin 718 and 719), FLUKE-717 1G Pressure Calibrator FLUKE-717 30G Pressure Calibratorsafety sheet.FLUKE-717 100G Pressure Calibrator FLUKE-717 300G Pressure CalibratorFLUKE-717 500G Pressure Calibrator FLUKE-717 1000G Pressure CalibratorFLUKE-717 1500G Pressure Calibrator FLUKE-717 3000G Pressure CalibratorFLUKE-717 5000G Pressure CalibratorFor a full list of Fluke 700 Pressure Modules, visit www.fluke.com/pressure.Recommended kits700ILFIn-Line FilterSee page 59700LTP-1Low Pressure<strong>Test</strong> PumpSee page 59700HTP-1C116Hydraulic <strong>Test</strong> PumpLarge Soft CaseSee page 59 See page 54Check price and availability atwww.fluke.com/wtb38Process Calibration <strong>Tools</strong>For more information, go to www.fluke.com/pressure
Intrinsically Safe ProductsCalibrators, thermometers and multimetersdesigned to intrinsic safety standardsWhat is “Intrinsically Safe”?Intrinsic safety is a protection method employed in potentially explosive atmospheres.Devices that are certified as “intrinsically safe” are designed to be unable to releasesufficient energy, by either thermal or electrical means, to cause ignition of flammablematerial (gas or dust/particulates).There are no global intrinsically safe standards or certifications, but there are organizationsthat influence directives in certain world geographies.Fluke products87V Ex: IntrinsicallySafe True-rms MultimeterFactory Mutual – In the United States, Factory Mutual Research,managed by Factory Mutual (FM) Global, is a non-profit scientific andtesting organization that has tested and certified over 40,000 productsin the last 165 years. FM Research has set certification guidelines forequipment used in potentially explosive atmospheres.Canadian Standards Association (CSA) – Accreditation body forNorth American regulations, based in Toronto, Canada.ATEX – The primary intrinsically safe standard, which has been setin the European Union with the Directive 94/9/EC, commonly calledATEX (“Atmosphères Explosibles”), French for explosive atmospheres.For more information and detailed specifications, turn to the correspondingnon-intrinsically safe product pages (Fluke 707, 718, 725,574, 68) or go to www.fluke.com/ex.707Ex: IntrinsicallySafe mA Calibrator718Ex: IntrinsicallySafe Pressure CalibratorATEX certifiedNorth AmericanCertificationFor additionalproduct detailII 2 G Ex ia IIC T4 See page 12II 2 G Ex ia IIC T4 N.I. Class I, Div 2,Groups A-D T4See page 34Specialty modelsFluke 68IS Intrinsically SafeInfrared Thermometer• Laser guided sightingsystem with 1 % accuracy• 12-point data logging• Advanced optics• Adjustable emissivity• Selectable Max/Min/Dif/Avgfunctions that display valuesinstantly with Hi/Lo Alarm• Expanded measurementrange up to 760 °C (1400 °F)• RTD probe accessory included• Class I, Division 1, Groups A,B, C, D Class I, Zone 0, AEx ia IIC,T4 at 50 °C when used with 9 Valkaline batteryNot available for purchase in Europe.574-NINonincendiveThermometerFor data loadingand extra safetythe Fluke 574Nonincendive (NI)Thermometer hasthe same great features as the 574model thermometer with the extra confidenceof a Factory Mutual approvalfor use in hazardous environments.Class I, Division 2, Groups A, B, C, D: Class I, Zone 2 IIC;T4 Ta=50 °C when used with 1.5 V alkaline batteries.725Ex: Intrinsically SafeMultifunction CalibratorII 1 G Ex ia IIC T4Groups A-D T4See page 38ResourcesMore info online atwww.fluke.com/processtoolsII 1 G Ex ia IIB 171 °CGroups B-D, 171 °CSee page 36Take a look at all the intrinsically safemodels at www.fluke.com/insafety700PEx: IntrinsicallySafe Pressure ModulesII 1 G Ex ia IIC T4 I.S. Class I, Div 1,Groups A-D T4See page 38Fluke 574-NI NonincendiveInfrared ThermometerClass I, Division 2,Groups A, B, C, D;Class I, Zone 2 IICSee page 50All the information you need atwww.fluke.com/processsolutionsFluke 68IS Intrinsically SafeInfrared ThermometerClass I, Division 1,Groups A, B, C, DClass I, Zone 0 AExia IICOrdering informationModelsModelsFLUKE-87VEx IS True-rms Multimeter FLUKE-707Ex IS Loop CalibratorFLUKE-718Ex IS Pressure Calibrator FLUKE-725Ex IS Multifuction Process CalibratorFLUKE-700PEx Pressure Modules (700P: 01, 5, 6, 9, 24, 27,29, A4Ex)FLUKE-574-NI Precision Infrared Thermometer w/Logging SWNonincendiveFLUKE-68IS Infrared Thermometer Intrinsically SafeCheck price and availability atwww.fluke.com/wtbFor more information, go to www.fluke.com/exProcess Calibration <strong>Tools</strong>39