12.07.2015 Views

Prod Sheet Venmar AVS HRV EKO 1.5 (91414):F.T. AVS SOLO 1.5 ...

Prod Sheet Venmar AVS HRV EKO 1.5 (91414):F.T. AVS SOLO 1.5 ...

Prod Sheet Venmar AVS HRV EKO 1.5 (91414):F.T. AVS SOLO 1.5 ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

HEAT RECOVERY VENTILATOR<strong>Venmar</strong> <strong>AVS</strong> <strong>HRV</strong> <strong>EKO</strong> <strong>1.5</strong>Part no. 4390080 to 157 CFM 53 to 106 CFM66 to 132 CFM 40 to 80 CFMCONTROLS•This unit is very simple to operate. Once it is installed, presson its push button, located under the unit, to activate it.Press once for low speed, once again for high speed, andonce more to stop it.•The Altitude main control no. 40440 is included and allows youto manage your ventilation with a new programmable mode.Also included, our unique and fully automated optimizer modecalled the Smart mode. The Altitude brings your ventilationexperience to new heights.•Also, one to 5 of the following optional controls can beadded:-20/40/60-min. Push-Button Timer No. 03364-60-min. Mechanical Timer No. 00910Discover the new generation of <strong>Venmar</strong>air exchangers: ultra-efficient andenvironmentally-friendly.The <strong>AVS</strong> <strong>HRV</strong> <strong>EKO</strong> <strong>1.5</strong> has been designed to be one of themost eco-friendly <strong>HRV</strong> air exchangers on the market. Itsinnovative design incorporates extremely high performanceECM* motors, which enable <strong>EKO</strong> to significantly lower energycosts without affecting its performance. Additional energyefficiency is found through its advanced heat recovery core,which can retain up to 80% of home’s heating. <strong>EKO</strong>surpasses energy-saving standards while providing effectiveheat recovery, ventilation and quiet operation. All aspectshave been designed to facilitate balancing of air flow andsimplify uses and installation.∙ Small-sized cabinet∙ High performance ECM* motors∙ Faster and easier installation of insulated flexible ductswith practical straps (exclusive to <strong>Venmar</strong>)∙ Integrated balancing dampers (exclusive to <strong>Venmar</strong>)∙ Integrated electronic board on motors∙ Homeshield defrosting system∙ Heat recovery core with superior capacity∙ Optimized drainage systemREPAIRS AND MAINTENANCEThe <strong>AVS</strong> <strong>HRV</strong> <strong>EKO</strong> <strong>1.5</strong> high output ECM* motor arepermanently lubricated. The electronic circuit board eliminateselectromechanical parts, reducing repair time to a minimum.WARRANTYThe <strong>AVS</strong> <strong>HRV</strong> <strong>EKO</strong> <strong>1.5</strong> unit is protected by a complete 5-yearwarranty on all parts. The heat recovery core is covered by alimited lifetime warranty, with the original proof of purchase.*Electronically Commutated MotorAvailable at:VB0122OPTIONS•Complete line of registers and diffusers•Electric duct heaterHOMESHIELD DEFROSTING SYSTEMThe <strong>AVS</strong> <strong>HRV</strong> <strong>EKO</strong> <strong>1.5</strong> uses a unique defrosting method. Nonegative pressure is created by air exhausted to the outside,as the air is recirculated into the house, thus avoiding anybackdraft from the chimney. Moreover, this defrost methodby air circulation ensures that no shortage of air is created forthe combustion units.VF0046STALE AIRFROM BUILDINGFILTERED AIRTO BUILDINGOUTSIDETEMPERATUREDEFROST CYCLEDEFROSTING MIN./°C °FOPERATING MIN.WARMERTHAN -5WARMERTHAN 23NODEFROST-5 to -27 23 to -17 7/25-27 &less-17 &less10/22HEAT RECOVERY COREDimensions: 10” x 10” x 14.25” (25.4 cm x 25.4 cm x 36.2 cm)Exchange surface: 110 ft² (10.2 m²)Weight: 7.36 lb (3.3 kg)Material: PolypropyleneType: Cross FlowWarranty: Limited LifetimeREQUIREMENTS AND STANDARDS•Complies with the UL 1812 requirements regulating theinstallation of Heat Recovery Ventilators.•Complies with the CSA C22.2 no. 113 Standard applicableto ventilators.•Complies with CSA C444 requirements regulating theinstallation of Heat Recovery Ventilators.•Technical data was obtained from published results oftests relating to CSA C439 Standards.•HVI certified.


DIMENSIONS AND SERVICE CLEARANCES: <strong>Venmar</strong> <strong>AVS</strong> <strong>HRV</strong> <strong>EKO</strong> <strong>1.5</strong>23 9 /16”(599 mm)2 ¹/16”(53 mm)3 13 /16”(97 mm)24 9 /16”(624 mm)22 ½”(572 mm)POWERCORD 3’137 7 /16”(189 mm)24VK0066A14 1 /16”(358 mm)14 15 /16”(380 mm)18 ¼”(464 mm)NOTE: Every port fits 6” round duct.1. EXHAUST AIR TO OUTSIDE2. FRESH AIR FROM OUTSIDE3. EXHAUST AIR FROM BUILDING4. FRESH AIR TO BUILDINGVENTILATION PERFORMANCEEXT. STATICNET SUPPLYPRESSURE AIR FLOWSUPPLYEXHAUSTPa in. w. g. l/s cfm m³/h l/s cfm m³/h l/s cfm m³/h25 0.1 89 189 320 89 190 320 87 185 31350 0.2 83 177 299 84 179 302 83 177 29975 0.3 79 167 284 79 169 284 79 167 284100 0.4 74 156 266 74 158 266 73 155 263125 0.5 69 136 248 69 148 248 68 146 245150 0.6 64 136 230 64 137 230 63 133 227175 0.7 59 126 212 60 127 216 58 123 209200 0.8 54 115 194 54 116 194 51 108 184225 0.9 47 110 169 47 101 169 45 96 162250 1.0 40 86 144 41 87 148 38 80 137275 1.1 35 74 126 35 75 126 31 65 112ENERGY PERFORMANCESUPPLYNET AIRTEMPERATURE FLOWºC ºF L/S CFMPOWERCONSUMEDWATTSSENSIBLERECOVERYEFFICIENCYSPECIFICATIONS AND RATINGSGROSS AIR FLOWAPPARENTSENSIBLEEFFECTIVENESSLATENT/RECOVERYMOISTURETRANSFERHEATING0 32 23 49 24 75 83 0.010 32 30 64 26 74 80 0.010 32 38 81 32 73 78 0.010 32 57 122 54 67 72 0.01-25 -13 29 61 40 64 89 0.02•Model: <strong>Venmar</strong> <strong>AVS</strong> <strong>HRV</strong> <strong>EKO</strong> <strong>1.5</strong>•Part Number: 43900•Total Assembled Weight (includingpolypropylene core): 52.4 lb (23.8 kg)•Oval shaped ports; fit 6” round ducts•Drains:1/2” (1.2 cm) fittings with10 ft (3 m) PVC drain•Core filters: 2 washable Merv 99.2” x 14.25” x 3.8” (23.4 x 36.2 x 9.6 cmNOTE:EXTERNAL STATIC PRESSUREin. w. g. (Pa= n x 248.36)1.21.00.80.60.40.20.0VG0083•Cabinet: Pre-painted steel•Insulation: Expanded polystyrene•Mounting: Suspension bychains and springs•Supply & Exhaust Blower Motors:2 ECM motors-Protection type: Thermally protected-Insulation class: B•Speed Control on unit:- Low and High speed.- Other modes available with Altitudemain control.Submitted by: Date: Project:Qty.: Model no.: Remarks: Location:Architect:Engineer:Contractor:4 3 2 10 25 50 75 100 125 150 175 200GROSS AIR FLOWCFM (l/s = cfm x 0.4719) (m³/h = l/s x 3.6)1. SPEED RANGE 1: 80 TO 157 CFM2. SPEED RANGE 2: 66 TO 132 CFM3. SPEED RANGE 3: 53 TO 106 CFM4. SPEED RANGE 4: 40 TO 80 CFMAll specifications are subject to changewithout notice.SUPPLY (CFM)EXHAUST (CFM)•Heat Recovery Core:- Heat Exchange Surface Area:110 ft² (10.2 m²)- Type: Cross Flow- Material: Polypropylene•Unit Electrical Characteristics:Volts Frequence Amperes Watts120 60 Hz 1.3 98Residential <strong>Prod</strong>uct Group, 550 Lemire Blvd., Drummondville, QC, Canada J2C 7W9 - Tel.: 1-800-567-3855 Fax: 1-800-567-1715R 2000www.venmar.ca 09/04 PRODUCT SHEET NO. <strong>91414</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!