Kollmorgen 06/2012 Electrical installation8.14.3 Master-slave operation8.14.3.1 Connection to an S700 master, 5V signal level (X1)You can link two S700 amplifiers together in master-slave operation. One slave amplifiercan be controlled by the master, via the encoder output X1 (see p. 94).Master:Slave:position output to X1 (screen page "Encoder emulation")screen page "Electronic gearing" (GEARMODE)Frequency limit: 1.5 MHzExample for Master-Slave operation with two S700 amplifiers:Slave GEARMODE: 30Master ENCMODE:9S700S700If using SSI emulation, then the master must be set to ENCMODE 10 and the slave toGEARMODE 25.8.14.3.2 Connection to an S700 Master, 5V signal level (X5)If an expansion card PosI/O or PosI/O-Monitor (see p.140 ff) is built-in, you can use theencoder emulation via X5. With this interface up to 16 Slaves can be connected to oneMaster, because no internal termination resistors are built-in with X5. Wiring see p.145.S701x2-S724x2 Instructions Manual 93