<strong>H0300</strong> <strong>Event</strong> <strong>Logger</strong>The SELCO <strong>H0300</strong> <strong>Logger</strong> is a standalonelogger system for the SELCOM1000C Alarm Annunciator, theM3000-30 Analog Alarm Annunciator,the SELCO M4780 Indicator and theSELCO H1500 Indicator Panel.• Stand-alone logger unit• <strong>Event</strong> log in display• <strong>Event</strong> log on printer• Repeating events from one slave unitto another• Built-in siren relay• Supports M1000C, M3000-30,M4780 and H1500• RS485 interface for field-buscommunication• Standard MODBUS-RTU protocol• Cable length up to 1000 metres onthe bus• PC configuration via RS232 interfacePWRRUNNOYES<strong>H0300</strong> EVENT LOGGER02-04 10:24:05High Oil Temp.CFG12345Communication errorPrinter errorNonacknow. alarmInvalid responseNew alarmApplicationThe <strong>H0300</strong> <strong>Event</strong> <strong>Logger</strong> can log alarmsand events from SELCO alarm monitorsand indicator panels, connected to acommon 2-wire RS485 interface bus.Up to 63 units can be connected to thebus, where the maximum cable lengthis approximately 1000 metres.All events from the units are loggedwith related date and time. The latest 32events are stored in the internalmemory of the <strong>H0300</strong>.A standard Centronics printer can beused for printout of all events.The <strong>H0300</strong> can also be configured to actas an event repeater. It can transfer LEDindications from one unit to anotherthrough the common bus.Multiple relations between sourceunit - LEDs and destinationunits - LEDs, where to repeat theindications, can be defined.RS485 repeaters can be used forextension.The <strong>H0300</strong> can survey a total of 63 unitsand it provides instant visible andaudible alarm, should the communicationfail to any one of the connectedunits.The unit has a built-in siren relay foraudible annunciation. Alarms andevents can be acknowledged at the frontpanel.A back-lit display is provided for on-sitemonitoring of the latest 32 events. Eachevent is logged with date and time.The display will automatically showboth device number, channel number,LED state and a 32-character descriptivetext.The user can acknowledge each of thealarms located in the log by using thefront panel keyboard.FunctionThe <strong>H0300</strong> connects to the M1000,M3000, M4780 and the H1500 by themeans of a two-wire RS485 serialcommunication bus.The maximum length of the bus cable is1000 metres; however various kinds ofFig. 1. <strong>H0300</strong> print out.


Four arrow keys are provided fornavigation among the events in thememory log.By default the display will show actualdate and time plus the number ofunacknowledged events present in thememory log.The log has a battery backup system topreserve its contents during a possiblepower disruption.A standard parallel printer with aCentronics interface can be connecteddirectly to the <strong>H0300</strong>. The printer willprovide a hard copy of the log showingevery event captured by the <strong>H0300</strong>.Each event is logged with date, time,unit number, channel number and adescriptive text. The log will also showany change made to the configurationof the <strong>H0300</strong>.The correct function of the printer iscontinuously surveyed by the <strong>H0300</strong>.The printer must support 80 charactersper line.The <strong>H0300</strong> can also perform an eventrepeating function. This functionprovides the convenient feature oftransmitting a LED indication from oneunit to another (through the 2-wire busconnection).The user can define any number ofrelations between the LEDs of the unitsconnected to RS485 bus. Thereby it isnot necessary to hardwire outputs toinputs, as the indication is transmittedover the common two-wire busconnection.On the front panel of the <strong>H0300</strong> are fiveLEDs. These LEDs provide visibleindication of alarm status, communicationand printer errors.A retractable paper label is provided forlocal language descriptions. Two LEDswill show the operational status of the<strong>H0300</strong>.The <strong>H0300</strong> includes a real time clockand calendar. The date and time can beset directly on the unit. Summer andwinter times are adjusted automatically(can be disabled).Various logging functions can also beconfigured using the front facia LCDand keyboard.Advanced configuration is donethrough the built-in RS232 connectionusing any personal computer with anANSI terminal application (e.g.Windows HyperTerminal - see fig. 4).Various commands are available, forinstance text descriptions of all eventscan be copied from the computer’sstorage to the <strong>H0300</strong> using a simplewrite-text command.On the rear panel are four dipswitcheswith the following functions (see fig. 2.):Dipswitch no.:1 Master mode (OFF)2 No summer / winter time change (ON)3 Printer is not used (ON)4 Configuration from keyboard is denied (ON)Resampling dipswitch 1: <strong>H0300</strong> canonly operate in master mode.SupplyConnection terminalsfor the 24V DCpower supply.RS485 MODBUSRS485 interface for field-buscommunication with MODBUSslave unit. MODBUS-RTU protocol.SirenInternal siren relay with a potential freecontact, which is activated at any newalarm and at communication error andprinter error.+<strong>H0300</strong> <strong>Event</strong> <strong>Logger</strong>_ A BSUPPLYRS485 MODBUSSIRENONDIP1 2 3 4CENTRONICSPRINTERPC RS232CentronicsCentronics interface forconnection to a standardparallel printer.RS232RS232 interface for PCbased configuration.SwitchesDipswitches with the following functions:1. Slave mode2. No summer/winter time change (ON)3. Printer is not used (ON)4. Configuration from keyboard is denied (ON)Fig. 2. Rear panel of the <strong>H0300</strong>.


NOYESCommunication errorPrinter errorNonacknow. alarmInvalid responseNew alarmLocation 1 (e.g. Engine Room)Location 2 (e.g. Pilot Bridge)Location 3-4-5PC SetupMess RoomM1000M10002-wire RS485MODBUS -RTU(max.1000 metres)PWRRUN<strong>H0300</strong> EVENT LOGGER02-04 10:24:05High Oil Temp.CFG12345RS232Captain’sCabinM1000<strong>H0300</strong>H1500Engineer’sCabinM3000Centronics Line PrinterM4700-80Fig. 3. <strong>Event</strong> Logging.<strong>H0300</strong> EVENT LOGGERPWRRUN02-RS232Fig. 4. Configuration via RS232 Interface using the HyperTerminal.


Specifications<strong>H0300</strong> <strong>Event</strong> <strong>Logger</strong>Fig. 5. Dimensions.Voltage supply 24V DC -30%/+30%ConsumptionBus systemSlave unitsMax. 120mA (24V DC), 160mA (16V DC)2-wire RS485Relations Max. 512ProgrammingDisplayKeyboardSiren relayAlarm LEDsRS485 parametersScanning periodRS232 parametersPrinterOperating temperatureEMCBurn-inWeightSupport for 63 units, M1000C, M3000-30, M4780 &H1500.Note that M3000-30 occupies two addresses in the systemBy keyboard / display or through RS232 (ANSI Terminal)Backlit 2 x 16 characters8 keysND/NE220V AC/2A30 V DC/2A/30W5 LEDsCommunication error (flashing)Printer error (flashing)Non-acknowledged alarm (steady)Invalid response (flashing)New alarm (steady)9600 bits per secondNone parity8 data bits1 stop bitT S= number of units x 16 msec.T Smax= 63 x 16 msec. = 1 sec.9600 bits per secondNone parity8 data bits1 stop bitCentronics parallel printer (DB25), 80 characters per line-10 to +70°CCE according to EN50081-1, EN50082-1, EN50081-2,EN50082-250 hours before final test0.5kgDimensions 96 x 144 x 64 mm (H x W x D)Panel cut outProtection degree at front IP5292 x 138 mmThe specifications are subject to change without notice.SELCO WorldwideMain Office:SELCO A/SBetonvej 10DK- 4000 RoskildeDenmarkPhone: + 45 - 70 26 11 22Fax: + 45 - 70 26 25 22e-mail: selco.dk@selco.comwww.selco.comH 0 3 0 0 - 7 3 E