TECHNICAL DATAR407CRTA/ECO/REC-FX 301 401 501 601 801CoolingCooling capacity (1) kW 97,1 132,2 161,5 189,3 244,1Absorbed power (1) (3) kW 34,4 44,2 54,3 64,7 79,1HeatingHeating capacity (2) kW 103,1 141,0 172,3 200,3 258,7Absorbed power (2) (3) kW 27,8 35,6 43,5 52,5 65,4Air flow m³/s 4,84 6,32 8,20 9,79 12,31Air treatment Available static pressure Pa 250 250 250 250 250sectionFans n° 1 1 1 1 1Filters Air flow m³/s 4,84 6,32 8,20 9,79 12,31Air intake section Available static pressure Pa 100 100 100 100 100Fans n° 1 1 1 1 1Compressors n° 1 1 1 1 1Type 1 1 1 1 1Refrigerant circuits n° Condening sectionCapacity steps n° 2 2 2 2 2Fans n° 2 4 4 4 6Air flow m³/s 6,4 14,0 13,4 12,8 19,3Power supply V/Ph/Hz ElectricalMax. running current A 252 283 353 462 584characteristicsMax. inrush current A 85 108 127 148 190Heating capacity (4) Kg 150 200 250 300 350Air pressure drops Pa 31 36 35 35 35Hot <strong>water</strong> coil Water flow (4) l/s 3,58 4,78 5,97 7,17 8,36Water pressure drops kPa 24 27 26 27 35Water connections ”G 1½” 2” 2” 2½” 2½”Power supply V/Ph/Hz Electric heatingHeating capacity kW 27 41 41 48 45Max absorbed current A 39 59 59 69 65Steps n° 2 4 4 4 4Sound pressure (5) STD dB(A) 66 63 63 65 63Transport weight STD Kg 2829 3849 4076 4570 4870Transport weight WP Kg 2849 3899 4126 4620 4940RTA/ECO/REC-FX 301÷801DIMENSIONSRTA/ECO/REC-FX 301 401 501 601 801LSTD mm 7530 9130 9230 9730 13600COMPACT mm 6170 7970 8070 8770 11250P STD mm 2325 2325 2325 2325 2325H STD mm 2390 2580 2580 2600 2600DIMENSIONALCLEREANCE AREAECO/REC-FX 301A mm 800mm 800C mm 800D (**) mm 1700RTA/ECO/REC-FX 401 ÷ 801A (**)mm 1000B mm 1700C mm 800D mm 1700NOTES(1) Evaporator inlet air temperature 27 °Cd.b. 19 °C w.b.; Ambient air temperature35 °C;(2) Condensator inlet air temperature 20 °C;Ambient air temperature 7 °C d.b./6 °C w.b.(3) Excluded the power absorbed by centrifugalfans.(4) Inlet air temperature 20 °C; Inlet <strong>water</strong>temperature 70 °C; Outlet <strong>water</strong> temperature60 °C.(5) Sound pressure level measured in freefield conditions at 1 m from the <strong>unit</strong>.According to ISO 3744.(**) D SIDE: Coil side.A SIDE: Electrical board side.137

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!