TECHNICAL DATAR407CCWW 182 202 262 302 364 404 524 604CoolingCooling capacity (1) kW 48,2 56,0 73,1 84,4 96,4 112,1 146,2 168,7Absorbed power (1) kW 13,0 15,0 19,7 22,9 26,0 30,0 39,4 45,7HeatingHeating capacity (2) kW 54,5 63,4 82,8 95,5 109,1 126,9 165,5 191,0Absorbed power (2) kW 15,2 17,7 23,2 26,8 30,6 35,6 46,4 53,6Quantity n° 2 2 2 2 4 4 4 4CompressorsType < - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Scroll - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ->Refrigerant circuits n° 2 2 2 2 4 4 4 4Capacity steps n° 2 2 2 2 4 4 4 4Water flow l/s 2,30 2,67 3,50 4,03 4,61 5,36 6,97 8,06Evaporator Pressure drops kPa 29 23 34 24 18 24 32 22Water connections ”G 1½” 2½” 2½” 2½” DN80 DN80 DN80 DN100Water flow l/s 2,92 3,39 4,43 5,13 5,85 6,79 8,87 10,24CondenserPressure drops kPa 15 14 27 35 15 14 27 35Water connections - IN ”G 2 x 1½” 2 x 1½” 2 x 1½” 2 x 1½” 4 x 1½” 4 x 1½” 4 x 1½” 4 x 1½”Water connections - OUT ”G 2” 2” 2” 2” 2 X 2” 2 X 2” 2 X 2” 2 X 2”Power supply V/Ph/Hz ElectricalMax. running current A 40 58 70 70 80 116 140 140characteristicsMax. inrush current A 150 159 210 210 190 217 280 280Sound pressure (3) STD dB(A) 60 63 70 70 62 65 73 72WeightsTransport weight Kg 611 617 663 688 902 918 1015 1084Operating weight Kg 630 640 690 720 940 960 1050 1130CWW 182÷604DIMENSIONSCWW 182 202 262 302 364 404 524 604LPHSTD mm 1950 2150 2380 2150 2150 2150 2400 2650SSL mm 1950 2150 2350 2150 2150 2150 2400 2650STD mm 810 810 810 810 810 810 810 830SSL mm 950 950 950 950 950 950 950 950STD mm 1400 1400 1400 1400 1500 1500 1500 1635SSL mm 1400 1400 1400 1400 1620 1620 1620 1750DIMENSIONALCLEREANCE AREACWW 182 ÷ 302A mm 1000B (*) () mm 800C mm 500D mm 500364 ÷ 604A mm 2100(*) () mm 800C mm 500D mm 500NOTES(1) Chilled <strong>water</strong> from 12° to 7°C. Condensing<strong>water</strong> from 30° to 35°C. With well <strong>water</strong>from 15 to 30°C, the cooling capacityincreases by 6% and the power inputdecreases by 12%.(2) Hot <strong>water</strong> from 40° to 45°C. Well <strong>water</strong>from 15 to 10°C.(3) Sound pressure level measured in freefield conditions at 1 m from the <strong>unit</strong>.According to ISO 3744.(*) B SIDE: Electrical board side.N.B. Weights of SSL and WP versions are indicatedon the technical book.89

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!