TECHNICAL DATAR407CMEA 802 902 1002 1102 1202 1502 1602CoolingCompressorsEvaporatorElectricalcharacteristicsSoundpressure (2)WeightsCooling capacity (1) kW 200 220 246 273 297 322 360Absorbed power (1) kW 65 71 80 88 96 104 117Quantity n° 2 2 2 2 2 2 2Type < - - - - - - - - - - - - - - - - - - - - - - - - - Semi-hermetics - - - - - - - - - - - - - - - - - - - - - - - - ->Refrigerant circuits n° 2 2 2 2 2 2 2Capacity steps n° 4 4 4 4 4 4 4Water flow l/s 9,56 10,51 11,75 13,04 14,19 15,38 17,20Pressure drops kPa 27 32 20 24 29 33 35Water connections ”G 100 100 125 125 125 125 125Power supply V/Ph/Hz Max. running current A 167 167 185 240 260 296 296Max. inrush current A 299 299 330 430 440 566 566STD dB(A) 65 65 65 65 66 66 66STD with SL accessory dB(A) 62 62 62 62 63 63 63SSL dB(A) 59 59 59 59 60 60 60Transport weight Kg 1050 1100 1135 1310 1330 1350 1410Operating weight Kg 1110 1160 1240 1415 1430 1450 1505MEA 802÷3204MEA 1604 1804 2004 2204 2404 3004 3204CoolingCompressorsEvaporatorElectricalcharacteristicsSoundpressure (2)WeightsCooling capacity (1) kW 401 439 492 546 595 644 720Absorbed power (1) kW 132 144 161 174 192 207 235Quantity n° 4 4 4 4 4 4 4Type < - - - - - - - - - - - - - - - - - - - - - - - - - Semi-hermetics - - - - - - - - - - - - - - - - - - - - - - - - ->Refrigerant circuits n° 2 2 2 2 2 2 2Capacity steps n° 4 4 4 4 4 4 4Water flow l/s 19,16 20,97 23,51 26,09 28,43 30,77 34,40Pressure drops kPa 41 30 48 49 57 40 43Water connections ”G 150 150 150 200 200 200 200Power supply V/Ph/Hz Max. running current A 335 335 371 480 520 592 592Max. inrush current A 466 466 516 670 700 862 862STD dB(A) 66 66 66 66 67 67 67STD with SL accessory dB(A) 63 63 63 63 64 64 64SSL dB(A) 60 60 60 60 61 61 61Transport weight Kg 1900 1940 1990 2550 2600 2650 2680Operating weight Kg 2045 2075 2115 2780 2830 2870 2900DIMENSIONSMEA 802 902 1002 1102 1202 1502 1602 1604 1804 2004 2204 2404 3004 3204LPHSTD 3100 3100 3100 3100 3100 3100 3100 3800 3800 3800 3800 3800 3800 3800SSL mm 3300 3300 3300 3300 3300 3300 3300 3800 3800 3800 3800 3800 3800 3800STD mm 780 780 780 780 780 780 780 1100 1100 1100 1100 1100 1100 1100SSL mm 780 780 780 780 780 780 780 1100 1100 1100 1100 1100 1100 1100STD mm 1400 1400 1400 1400 1400 1400 1400 1700 1700 1700 1700 1700 1700 1700SSL mm 1400 1400 1400 1400 1400 1400 1400 1700 1700 1700 1700 1700 1700 1700DIMENSIONALCLEREANCE AREAMEA 802 ÷ 1602A mm 500B mm 500C mm 500D () (*) mm 800MEA 1604 ÷ 3204A mm 500B (*) () mm 800C mm 500D mm 500NOTES(1) Chilled <strong>water</strong> from 12 to 7 °C, medium<strong>condensing</strong> temperature 45 °C.(2) Sound pressure level measured in freefield conditions at 1 m from the <strong>unit</strong>.According to ISO 3744.(*) D SIDE: Electrical board side.B SIDE: Electrical board side.N.B. Weights of SSL versions are indicated onthe technical book.105

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!