13.07.2015 Views

Delay on Operate Type DAA01, PAA01 Timers - Carlo Gavazzi

Delay on Operate Type DAA01, PAA01 Timers - Carlo Gavazzi

Delay on Operate Type DAA01, PAA01 Timers - Carlo Gavazzi

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Timers</strong><str<strong>on</strong>g>Delay</str<strong>on</strong>g> <strong>on</strong> <strong>Operate</strong><strong>Type</strong> <strong>DAA01</strong>, <strong>PAA01</strong>• Time range 0.1 s to 100 h• Knob selecti<strong>on</strong> of time range• Knob adjustable time setting• Automatic start• Repeatability: ≤ 0.2%• Output: 8 A SPDT or 2 x 8 A SPDT relays• For mounting <strong>on</strong> DIN-rail in accordance with DIN/EN50 022 or Plug-in• 22.5 Eur<strong>on</strong>orm or 36 mm plug-in module housing• Combined AC and DC power supply• LED indicati<strong>on</strong> for relay status and power supply ON<strong>DAA01</strong><strong>PAA01</strong>Product Descripti<strong>on</strong>Multi-voltage delay <strong>on</strong> operatetimer with 7 selectabletime ranges within 0.1 s and<strong>Type</strong> Selecti<strong>on</strong>100 h. For mounting <strong>on</strong> DINrail(<strong>DAA01</strong>) or plug-in(<strong>PAA01</strong>).Ordering KeyHousingFuncti<strong>on</strong><strong>Type</strong>Item numberOutputPower supplyDAA 01 C M24Mounting Output Housing Supply: 24 VDC and 24 to 240 VAC Supply: 24 to 240 VAC/DCDIN-rail 1 x SPDT D-Housing <strong>DAA01</strong>CM242 x SPDT <strong>DAA01</strong>DM24Plug-in 1 x SPDT P-Housing <strong>PAA01</strong>CM242 x SPDT <strong>PAA01</strong>DM24Time Specificati<strong>on</strong>sTime rangesKnob selectable0.1 to 1 s1 to 10 s6 to 60 s60 to 600 s0.1 to 1 h1 to 10 h10 to 100 hSetting accuracy ≤ 5%Repeatability ≤ 0.2%Time variati<strong>on</strong>Within rated power supply ≤ 0.05%/VWithin ambient temperature ≤ 0.2%/°CResetPower supply interrupti<strong>on</strong> ≥ 200 msOutput Specificati<strong>on</strong>sOutput1 or 2 x SPDT relaysRated insulati<strong>on</strong> voltage 250 VAC (rms)C<strong>on</strong>tact Ratings (AgSnO 2) µResistive loads AC 1 8 A @ 250 VACDC 12 5 A @ 24 VDCSmall inductive loads AC 15 2.5 A @ 250 VACDC 13 2.5 A @ 24 VDCMechanical life≥ 30 x 10 6 operati<strong>on</strong>sElectrical life≥ 10 5 operati<strong>on</strong>s(at 8 A, 250 V, cos ϕ = 1)Operating frequency < 7200 operati<strong>on</strong>s/hDielectric strengthDielectric voltage2 kVAC (rms)Rated impulse withstandvoltage4 kV (1.2/50 µs)Specificati<strong>on</strong>s are subject to change without notice (16.10.02) 1Gross Automati<strong>on</strong> (877) 268-3700 · www.carlogavazzisales.com · sales@grossautomati<strong>on</strong>.com


<strong>DAA01</strong>, <strong>PAA01</strong>Supply Specificati<strong>on</strong>sPower supplyOvervoltage cat. IIIRated operati<strong>on</strong>al voltage (IEC 60664, IEC 60038)through terminals:(<strong>DAA01</strong>C) A1, A2 or 24 VDC ± 15% and(<strong>PAA01</strong>C) 2, 10 24 to 240 VAC + 10% -15%,45 to 65 Hz(<strong>DAA01</strong>D) A1, A2 or 24 to 240 VAC/DC(<strong>PAA01</strong>D) 2, 10 + 10% - 15%,45 to 65 HzVoltage interrupti<strong>on</strong>≤ 10 msRated operati<strong>on</strong>al powerAC supply4 VADC supply1.5 WTime SettingCentre knob:Time setting <strong>on</strong> relativescale: 1 to 10 with respectto the chosen rangeOperating DiagramLower knob:Setting of time rangeGeneral Specificati<strong>on</strong>sPower ON delay≤ 100 msReacti<strong>on</strong> timeInstantaneous c<strong>on</strong>tact < 20 ms from power ONIndicati<strong>on</strong> forPower supply status LED, greenOutput statusLED, yellow(flashing when timing)Envir<strong>on</strong>ment (EN 60529)Degree of protecti<strong>on</strong> IP 20Polluti<strong>on</strong> degree3 (<strong>DAA01</strong>), 2 (<strong>PAA01</strong>)(IEC 60664)Operating temperature -20° to +60°C, R.H. < 95%Storage temperature -30° to +80°C, R.H. < 95%WeightApprox. 130 gScrew terminals (<strong>DAA01</strong>)Tightening torqueMax. 0.5 Nm according toIEC EN 60947UL, CSAYesApprovalsCE markingEMCElectromagnetic CompatibillityImmunity According to EN 61000-6-2Emissi<strong>on</strong> According to EN 50081-1Timer Specificati<strong>on</strong>s According to EN 61812-1Mode of Operati<strong>on</strong>Power supplyRelay 1ONOFFRelay 2 ON(<str<strong>on</strong>g>Delay</str<strong>on</strong>g>ed)OFFRelay 2 ON(Istantaneous)OFFTTThe yellow LED, flashingwhen timing, is ON as so<strong>on</strong>as the relay turns ON.The sec<strong>on</strong>d relay can operateas instantaneous ordelayed changeover c<strong>on</strong>tact.The selecti<strong>on</strong> is made by aDIP-switch placed under theplastic door <strong>on</strong> the device’sfr<strong>on</strong>t.is c<strong>on</strong>nected. At the end ofthe set delay the relay operatesand does not releaseuntil the power supply isinterrupted for at least 200ms. If the power supply isinterrupted for at least 200ms before the relay operatesthe time is set to zero andthe circuit is ready for a newtime period.LEDThe set delay period beginsas so<strong>on</strong> as the power supplyWiring Diagrams<strong>DAA01</strong><strong>PAA01</strong>L(+)L(+)A116 18 26 2824 3 8 9A215 25101 11N(-)<strong>DAA01</strong>C...<strong>DAA01</strong>D...<strong>DAA01</strong>D...N(-)<strong>PAA01</strong>C...<strong>PAA01</strong>D...<strong>PAA01</strong>D...2 Specificati<strong>on</strong>s are subject to change without notice (16.10.02)Gross Automati<strong>on</strong> (877) 268-3700 · www.carlogavazzisales.com · sales@grossautomati<strong>on</strong>.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!