13.07.2015 Views

Thermal Shock Chambers - MB Electronique

Thermal Shock Chambers - MB Electronique

Thermal Shock Chambers - MB Electronique

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

OPTIONSAmbient-temperature exposure (EL type only)Enables three-zone tests by adding adamper mechanism and an air circulator.· High temp. exposure range: +60 to 200°CRecorder terminalUsed to output the temperature within testarea, hot chamber, and cold chamber.ThermocoupleAt t a ched t o speci me n s t o measu respecimen temperature.· 2, 4, 6m· Thermocouple type T (Copper, copper-nickel)Exposure signal outputA signal is output via a contact switch whentest area temperature is within the userselectedrange. This signal can be used tocontrol peripheral instruments, likeapplying a voltage to specimens only duringhigh temperature exposure, or monitoringtest operation from a remote point.Preparation of a power cable, temperaturesensor, and conductor grounding wire foradditional installation in the future.Paperless recorderRecords the temperature of each section such asthe temperature inside the chamber.PL1S: Number of inputs: 1 (5 OFF*)Scan interval: 1 sec.PL3S: Number of inputs: 3 (3 OFF*)Scan interval: 1 sec.PL3L: Number of inputs: 3 (3 OFF*)Scan interval: 5 sec.PL4S: Number of inputs: 4 (2 OFF*)Scan interval: 1 sec.PL4L: Number of inputs: 4 (2 OFF*)Scan interval: 5 sec.PL5S: Number of inputs: 5 (1 OFF*)Scan interval: 1 sec.PL5L: Number of inputs: 5 (1 OFF*)Scan interval: 5 sec.· Temperature range: –100 to +220°C· External memoryCF memory card port(Includes a 256 <strong>MB</strong> CF card)USB memory port· Languages: English/Japanese, can be changed* Channels can be turned ONTemperature recorder (digital display)RK–61 1 penRK–63 3 pensRK–64 6 dots· Temperature range: –100 to +220°C· Effective recording chart width 100 mmRecorder wiringPreparation of a power cable, temperaturesensor, and conductor grounding wire foradditional installation in the future.Additional overheat protectorsAdditional preventive measures can betaken for excessive temperature rise in thechamber, in addition to the standardequipped overheat protector.External alarm terminalIf the safety device of the chamber isactivated, the external alarm terminal willnotify it to a remote point.Emergency stop pushbuttonStops the chamber immediately.Status indicator lightTo check the state of the chamber fromdistant locations.Total cycle counterIndicates cycle counts.· With reset function· Display range: 1 to 99999999Built-in air compressorSelect when there is no air supply source.Power meterAccumulates the amount of power the chamber uses.18

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!