Additional informationEnclosure characteristicsSelection of enclosuresaccording to the premisesThe IP and IK degrees of protection provided by an enclosure must be specified asa function of the various external influences defined by standard IEC 30364-5-51,in particular:bbpresence of foreign solid bodies (code AE)bbpresence of water (code AD)bbmechanical stress (code not specified)bbcapability of persons (code BA)b b...<strong>Prisma</strong> <strong>Plus</strong> switchboards are designed for indoor installation.Unless the rules, standards and regulations of a specific country stipulate otherwise,<strong>Schneider</strong> <strong>Electric</strong> recommends the following IP and IK values based on Frenchguide UTE C 15-103 (March 2004).Using the table1 Opposite the relevant premises, read the recommended IP and IK values.2 The b symbol indicates the enclosure or cubicle satisfying the criteria of the UTEguide.Any enclosure or cubicle with a higher degree of protection can also be used.3 If several degrees of protection are possible (refer to the standard for moredetails) and the v and b symbols are indicated (e.g. 24 v /25 b ), enclosures thatcorrespond to the higher degree of protection (b) are suitable for the lowerdegree of protection (v).Example:Selection of an enclosure for a laundry room.Minimum degree of protection: IP21/IK02A wall-mounted enclosure with a door (plain or transparent), a canopy and a gasketoffer IP43/IK08 degrees of protection and are therefore suitable for this application.Type of premisesEnclosuresWall-mountedenclosure without door with door with door + canopy with door + canopy +gasketFloor-standingenclosureMin. IP/IKrequiredIP IKwithout door with door with door + canopy with door + canopy+gasketIP30/IK07 IP30/IK08 IP31/IK08 IP43/IK08 IP55/IK10Domestic or comparable premises or locationsPorch 24 07 b bBathrooms (see washrooms)Bicycles, motorcycles, tricycles, etc.(premises for)Water, sewer and heatingconnections20 07 b b23 02 b bLaundries 21 02 b bCellars, garages, furnace rooms 20 02/07 b bBedrooms 20 02 b bTrash rooms 25 07 b bHalls in cellars 20 07Courtyards 24/25 02/07 b bKitchens 20 02 b bShower rooms (see washrooms)Indoor stairways and alleys 20 02/07 b bOutdoor stairways and outdoor 24 07alleys without roofsOutdoor alleys with roofs 21 02 b bAttics (roof space) 20 02 b bGarden shelters 24/25 02/07 b bLatrines 20 02 b bDustbin rooms 25 02/07 b bIroning room 20 02 b bAccess ramps to garages 25 07 b bN/AIP55151

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!