13.07.2015 Views

Prisma Plus G - Schneider Electric

Prisma Plus G - Schneider Electric

Prisma Plus G - Schneider Electric

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Functional systemDistributionNon-Centralised distribution630 A insulated busbarPowerclip busbars 160 / 630 APD390545PD390546PD391009Tap-off blocks for 6 mm²and 10 mm² cableClip-on covers that block offthe connected cable lugsCompact busbars, IPxxB,ready for installation in theswitchboard (supplied withsupports and extremityobturators)ETP H12 channelled copperbars with threaded M6 holesevery 25 mm, can be cutevery 200 mmBars mounted on insulatedbases that screw to thefunctional upwrightsWide choice of prefabricatedand tested connectionsClip-on covers to protectagainst direct contacts fromthe front (IPxxB). They canbe easily cut for theconnections to the devicesPD390337200 A connection for Multiclipdistribution blockThe ends are protected byextremity obturators160 A 250 A 400 A 630 APowerclip busbars 3P W = 1000 mm 04111 04112 04113 04114W = 1400 mm 04116 04117 04118 041194P W= 1000 mm 04121 04122 04123 04124W = 1400 mm 04126 04127 04128 04129Additional accessories* 2 Powerclip supports01210 01210 01210 01211+ 2 extremity obturators+ mounting hardwareSpare parts* 2 IPxxB clip-on covers, L= 200 mm 01201 01201 01201 01201* For more information > see page 103<strong>Electric</strong>al characteristicsRating Rated withstand current max. Rated levelShort-time withstand current Icw Withstand peak Ipk Insulation Ui Impulse withstand voltage Uimp(kA rms / 1 s) (kÂ) (V) (kV)160 A 10 30 750 8250 A 13 30 750 8400 A 20 52,5 750 8630 A 25 52,5 1000 8Choice of connections depending on devicesDevice to connectCatalogue numbers (see details on next page)Compact NSX400 horizontal 04070NSX NSX630 horizontal 04071NSX400/630 vertical with or without Vigi 04074 + connection must be made (in enclosure) or 04074 + 04073 (in duct)NSX100/250 horizontal with or without Vigi 04060NSX100/250 vertical without Vigi 04061 + 04062 (in enclosure) or 04061 + connection must be made (with rotary handle in enclosure) or 04061+ 04064 (in duct)NSX100/250 vertical with Vigi04061 + connection must be made (in enclosure)04061 + 04064 (in duct)Interpact INS-INV250 horizontal 04060INS-INV INS-INV320/400 horizontal 04070INS-INV500/630 horizontal 04071INS-INV250 vertical04061 + 04062 (in enclosure) or 04061 + 04064 (in duct)INS-INV320/630 vertical04074 + connection must be made (in enclosure) or 04074 + 04073 (in duct)Fupact INF100/160 horizontal 04155 + connection must be made (3P) or 04156 + connection must be made (4P)INF100/160 vertical04061 + connection must be madeISFT 100/250 vertical or horizontal 04061 + connection must be madeINS INS40/125 3P 04145 + 289474P 04145 + 28948INS160 04147 or 04148 or 04146NG NG125 04145 or 04147 or 04148 or 04146NG160 04147 or 04148 or 04146Vigi NG160 04148NSA160 04147 or 04148 or 04146C120, iC120 04147 or 04148Multiclip 63/80/160 A 04151 or 04152200 A 04021Modular devices 04151 or 0415268

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!