13.07.2015 Views

Operation - Weber Ultrasonics GmbH

Operation - Weber Ultrasonics GmbH

Operation - Weber Ultrasonics GmbH

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

SONIC DIGITAL LC - Ultrasonic generators4.) Signal “HF-DA ERROR” DSUB PIN 5/9Shared in/output for the internal relays “HF-DA” and “ERROR” (these PINs are connected internally).5.) Signal “HF-DA” DSUB PIN 6If the ultrasonic generator has been switched on via either of the signals “FS-24 V”, “FS-GND”or with the test button on the front panel and is emitting HF voltage (i.e. there is no malfunction),an internal floating relay contact is closed. (between PIN 6 und PIN 5/9)www.weber-ultrasonics.comThe “root” of this relay contact leads through to a PIN 5/9 (these pins are connected internally)in the DSUB socket. This relay contact can now be queried by an external control system.A voltage connected to Pin 5/9 can, of course, also be switched through (max. 24 VDC / 100 mA).It is useful to query this contact when a timer operation is being carried out and the generator switchesoff automatically when the time is up (normally closed contact default setting). The contact can also beswitched over to reverse polarity in the Settings menu.Standard factory setting: Contact closed when the generator outputs HF voltage.6.) Signal “Error” DSUB PIN 7This is the output of an internal relay (root to PIN 5/9).This relay reports generator malfunctions. This means that if the generator is switched on and,for some reason, the power output does not correspond to the set level, this relay is activated.Factory default settings: Closed in the event of a malfunction. It is possible to change the polarityin the Settings menu under the heading I/O Polarities (“Error detect”).An external voltage connected to “HF-DA-Error” can, of course, also beswitched through here (max. 24 VDC / 100 mA).7.) Signal “FAN-ON” DSUB PIN 12At this output, there is a control voltage (12 Volt) for monitoring the fan function when the internal fan is running.8.) Signal “FS-24 Volt” DSUB PIN 13Switching on the generator (Ultrasound On) by connecting a voltage between 15 – 24 Voltbetween PIN 13 and GND (PIN 4/15).9.) Signal “FS-GND” DSUB PIN 14Switching on the generator (ultrasound ON) with a relay contact or switch by connectingPIN 14 on the DSUB socket to GND (PIN 4 /15).10.) Signal “ Nominal” DSUB PIN 11Open Collector output: high signal if a window function is active and the generatoris operated outside the window set; low signal if a window function is active andthe generator is operated within the window set.11.) Signal “GND” DSUB PIN 4, 15The GND signal is available on multiple pins of the DSUB socket.It is the common reference point for all input and output signals.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!