13.07.2015 Views

MVS and CVS-R - Optex FA

MVS and CVS-R - Optex FA

MVS and CVS-R - Optex FA

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

ParametersFunctionLCD Disp.BrightnessBRIGHTInitializingsetting valueINITIALOff delayOFF DLYOn delayON DLYOne shotONESHOTOutput reverseOUTSIDEResolutionRESOLUTSynchronousinputSYNCHROLCD DispLCD DispSetting range(Default)0 to 255(100)NO, YES(NO)0 to 5000(0)0 to 5000(0)OFF,ON(OFF)LOW,HIGH(LOW)LOW,HIGH(LOW)OFF,ON(OFF)DescriptionSpecifies the brightness of the screen (shutter time).The optimal value is set at teaching. The shutter timeis calculated with "the setting value x 54.5 µs."Initializes all the set values by setting "YES."Sets the Off delay time of output. When set to oneshot (ONESHOT = ON), the value means period ofoneshot output. (Unit: ms)Sets the On delay time of output. (Unit: ms)Switches to the oneshot output. The time isspecified by the value of OFF DLY.Switches the relationship between the area <strong>and</strong> theoutput.LOW: The output turns on when the area is equal toarea threshold or more than that.HIGH: The output turns on when the area is less thanarea threshold.Specifies the resolution of the image to be captured.LOW: Reduces the horizontal resolution <strong>and</strong>response time to half. Effective for fast moving objectthat doesn't need higher resolution.HIGH: Doesn't reduce the resolution.OFF: Capture continuously.ON: Capture at the rising point of synchronousinput (purple).displayed in yellow: the setting item is common to all banks.displayed in purple: the setting item switches to the specific value of each bank.When switching banks changing resolution <strong>and</strong> zoom rate, theimage sensor may take approx. 2 seconds to be stable. Set sameresolution <strong>and</strong> zoom rate when change banks continuously.Connection diagramPhoto couplerInternalcircuitPhoto couplerInternalcircuitProtection diodeInternalcircuitBank tableCable ColorOrange/BlackYellow/BlackPink7.5k7.5kProtection diodeInternalcircuit15k15kSignalBank selection 0 inputBank selection 1 inputBank selection 2 input0OFFOFFOFF12-24VDC (Brown)Bank select 0 (Orange/Black)Bank select 1 (Yellow/Black)Bank select 2 (Pink)Synch input (Purple)Output (Black)0V (Blue)0V (Blue)Bank select 0 (Orange/Black)Bank select 1 (Yellow/Black)Bank select 2 (Pink)Synch input (Purple)Output (Black)12-24VDC (Brown)1ONOFFOFF2OFFONOFFBank No.3 4ON OFFON OFFOFF ON5ONOFFON(NPN)(PNP)6OFFONON7ONONONField of View<strong>CVS</strong>1easy-N10-R Long range typeOFFONNPN: OPEN or connect with the brown line.PNP: OPEN or connect with the blue line.NPN: connect with the blue line.PNP: connect with the brown line.<strong>CVS</strong>1easy-N40-R Macro view type210mm270mmWorking distance40×50mm 55×65mm50mm100mmWorking distance50×65mm 100×115mm<strong>CVS</strong>1easy-N20-R St<strong>and</strong>ard type<strong>CVS</strong>1easy-N21-R Narrow view type35mm17×20mm90mm150mmWorking distance40×50mm 65×75mmVision Sensor 34

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!