13.07.2015 Views

Transforming the healing environment - Dulux Trade

Transforming the healing environment - Dulux Trade

Transforming the healing environment - Dulux Trade

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

TECHNICALTechnical informationProductCoverage (approxper litre)Recoat(Hours)Application MethodVOCContentKeyBenefitsHTM 56CompliantSterishieldDiamond MattUp to 16m 2 /L 2-4 LowDurable, washable,silver bactericide1-6SterishieldQuick DryingEggshellUp to 17m 2 /L 2-4 LowDurable, washable,silver bactericide1-6Diamond Matt Up to 16m 2 /L 4-6 Low 10 x tougher 2-6DiamondEggshellUp to 16m 2 /L 4-6 Low10x morestain resistant2-6DiamondSatinwoodUp to 16m 2 /L 6 Low 10 x tougher 2-6Diamond Glaze Up to 25m 2 /L 2-4 Medium 10x tougher 2-6Light & SpaceFlat MattUp to 17m 2 /L 2-4 LowUses up to 22%**less light energy4-6Ecosure Matt Up to 17m 2 /L 2-4 MinimalVirtually zero VOC &zero solvent4-6EcosureQuick DryingEggshellUp to 16m 2 /L 4-6 MinimalVirtually zero VOC &zero solvent4-6Ecosure Gloss Up to 16m 2 /L 6 LowNon-yellowing,durable,high-sheen finish.2-6EcosureUndercoatUp to 16m 2 /L 6 LowGood opacity& adhesion2-6*HighPerformanceFloor PaintUp to 6m 2 /L 16-24 MediumFor heavycommercial<strong>environment</strong>s1-6Floorshield Up to 16m 2 /L 12-16 HighDurable &hard wearing1-6PyroshieldDurable MattUp to 12m 2 /L 2-4Minimal (white)Low (colour)Flame retardantdurable upgrade6Anti-graffitifinishUp to 10m 2 /L Minimum 16 MediumResistant to washing& cleaning1-6KEY Brush Roller Conventional Spray Airless Spray*Topcoat with Ecosure Gloss to achieve compliance.**This figure is based on <strong>the</strong>oretical calculations on pairs of bare rooms of dimensions 4 × 3 × 2.4m where <strong>the</strong> light incident on all surfaces is averaged.The rooms all have <strong>the</strong> same mid-grey floor colour (LRV 50). They have a white ceiling and a colour on <strong>the</strong> walls. In one of each pair, <strong>the</strong> colour used isfrom <strong>the</strong> Light & Space range. In <strong>the</strong> o<strong>the</strong>r, <strong>the</strong> colour used is from conventional products. The Light & Space and conventional colours have similar hue(colour family) and chroma (intensity of colour). The energy savings will not always equate to 22%. They will vary depending on <strong>the</strong> contents, dimensionsand floor colour of <strong>the</strong> room and will differ if lighting in particular areas needs to be controlled. The calculated figure varies from 14% to 28% dependingon <strong>the</strong> wall colour chosen. The actual light energy savings achieved in practice may differ from <strong>the</strong> calculations.| 31

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!