13.07.2015 Views

TMdrive®-XL Series Family Product Application Guide TMdrive®-XL ...

TMdrive®-XL Series Family Product Application Guide TMdrive®-XL ...

TMdrive®-XL Series Family Product Application Guide TMdrive®-XL ...

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

TMdrive-<strong>XL</strong> <strong>Series</strong>TMdrive-<strong>XL</strong>85 – 30 MVA FramePower Rating: 30 MVA, expandable to 120 MVAOutput Voltage: 7.2 kVOutput Frequency: Rated 50-60 Hz, 50 to 200 HertzDimensions:Motor type:Width 8.1 mHeight: 2.6 mSynchronous or InductionGate Commutated Thyristor(GCT) with driver board.Rated 6,000 Volts, 6,000Amps - the world’s largestswitching devicePower Input/OutputPower CircuitsAny utility voltage usingInput Voltageseparate transformer input50/60 Hz ±10%Output Voltage7,200 VacOutput Current2400 A rmsOutput Frequency 50-60 HzOutput Chopping600 Hz (max)Efficiency 98%Cable EntryTop or bottomClean Motor Output WaveAs a result of the fivelevelPWM control, theoutput current waveformis close to a sine wave.Harmonic currents inthe motor windings areLine-to-Line Voltage at 100% Speedminimized so the heatloss is negligible andthere is very little torqueripple on the output shaft.U-phase Current at 100% SpeedProtective Functions Include:• Inverter overcurrent• Inverter overvoltage• Low system voltage• Motor ground fault• Motor overload• Cooling fan abnormal• Over-temperature• CPU error• Water cooling alarm• Exciter fault• DC voltage drop• Motor inverse rotation• Stall detection• Ground detectionConverter• AC-fed 36-pulse diode rectifier using externallymounted phase shifted transformer; no harmonic filterrequired to meet IEEE 519 guidelines• DC bus voltage: 3 x 5,450 Vdc• Power factor greater than 95% in speed control rangeInverter• Five-level inverter for motor friendly wave form• Uses 8 GCT devices for each of three phases• 7.2 kV output to motor – no output transformerrequired• Inverter power modules water cooled• Conservative design for expected 20 year MTBFMotor ControlFrequency Control• Volt/Hertz Control – standard• Sensorless vector control – optional• Power factor control for synchronous motorsOutput Voltage ModulationThe output switching modulation strategy is dynamicallyadjusted based on three speed zones to minimize motortorque pulsation.Drive Inputs• LAN Interface Options: Profibus-DP, DeviceNet,Modbus RTU, TOSLINE• Input/Output: 6 Analog I/O, 8 Digital I/O6

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!