13.07.2015 Views

Operating Manual_DryCool HD.pdf - HTS

Operating Manual_DryCool HD.pdf - HTS

Operating Manual_DryCool HD.pdf - HTS

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

1.2.3.4.Disconnect power from the DRYCOOL <strong>HD</strong> unitRemove installation hole plug. This black plastic plugis located on the same end of the unit as the controlpanel and is above the condensate drain outlet.Insert support wire.Insert emitter into hole, ensuring that emitter ceramicend rests on support wire’s hook and that emitter collaris set firmly against hole perimeter.5.6.7.Cut spine in order to accommodate the support wire.Reinstall the spine pieces.Attach emitter extension cord to power supply, andplug power supply into the outlet on the DRYCOOL <strong>HD</strong>labeled “UV Light”.Power can now be reconnected to the MuntersDRYCOOL <strong>HD</strong> unit.2 Intended ApplicationThe DRYCOOL <strong>HD</strong> Dehumidifier is intended for installationin spaces that experience short or long term highhumidity conditions. Use of the DRYCOOL <strong>HD</strong> in poolareas will void warranty. In order to efficiently controlhumidity levels, the area in which the dehumidifier is tobe placed must be free of water intrusion or excessivefresh air infiltration. Before installation of the DRYCOOL<strong>HD</strong>, water intrusion or excess air infiltration shouldbe addressed.8”REACT INLETDO NOT place the DRYCOOL <strong>HD</strong> directly on structuralmembers.A secondary drain pan MUST be placed under the unit.The DRYCOOL <strong>HD</strong> should be located near the existing airhandling system to minimize the required ductwork. Thecontrols for the DRYCOOL <strong>HD</strong> are remote from the unit andmust be located in the space that is to be conditioned. Thecontrols are low voltage (24 volt) and should be connectedto the DRYCOOL <strong>HD</strong> with low voltage thermostat wire.8”SUPPLY OUTCOND. COILSQUARE TOROUND(OPTIONAL)If fresh air ventilation is desired, thought should be given tothe location for the fresh air ducting. An 8” round insulatedduct will have to be installed on the DRYCOOL <strong>HD</strong>and run to the outside of the structure to bring in fresh air.The unit is not meant to condition more than 75cfm of outside air. Consult local codes for necessarydistances from exhaust ports when installing fresh airreturn.SQUARE TOROUND(OPTIONAL)OPTIONALO.A. CONNECTIONDRAINEVAP.ELECT.UNIT DETAIL8”REACT OUTLETROUND OUTDO NOT use the DRYCOOL <strong>HD</strong> as a bench or table.2.1 SpecificationMODELElectricalCapacityEfficiency<strong>Operating</strong> Temp.Air FlowRefrigerantUnit SizeUnit WeightShipping WeightDRYCOOL <strong>HD</strong>115 / 60 / 1, 7 A @ AHAM120 Pints/day @ 80 °F DB / 60% RH3.3 L/kW50°FF – 95°FF250 CFM without external restrictionsRefrigerant Charge 28 oz. R41024 L x 36 W x 16.5 H95 lbs.110 lbs.5

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!