1020P3SuggestedSchematicswith Control and Power Wiring detailsOutside SensorMount in a sheltered positionon North facing wallLocal tempcontrolUnder floor HTG230v SupplyMains cold waterDHWLocal tempcontrolCondensate22mmFlow22mmReturn22mm GasHigh Tempdiverting valveUnder floor HTGLow lossheaderSystempumpAVS0020


Benchmark places responsibilities on both manufacturers and installers. The purpose is to ensure thatcustomers are provided with the correct equipment for their needs, that it is installed, commissioned andserviced in accordance with the manufacturer’s instructions by competent persons and that it meets therequirements of the appropriate Building Regulations. The Benchmark Checklist can be used to demonstratecompliance with Building Regulations and should be provided to the customer for future reference. Installersare required to carry out installation, commissioning and servicing work in accordance with the BenchmarkCode of Practice which is available from the Heating and Hotwater Industry Council who manage andpromote the Scheme.Visit www.centralheating.co.uk for more information.ContentsAVANTA PLUS System Options ON / Off Control (Internal modulating)1. Typical “Y” plan Heating and DHW using 230v controls 52. Typical “W” plan Heating and Priority DHW using 230v controls 63. Typical “S” plan Heating and DHW using 230v controls 74. Internal time clock Heating and Priority DHW using Celcia 10 and 3 way diverting valve kit 8Weather Compensation Control Direct modulating using ‘OpenTherm®’5. Simple weather compensated Heating with Priority DHW 96. Simple weather compensated Heating with room thermostat override (230v) and Priority DHW 107. Simple weather compensated Heating with room thermostat override (Celcia10) and Priority DHW 118. Time / Weather compensated Heating with Priority DHW (Celcia 20 -Digital clock) 12Room Compensation Control Direct modulating using ‘OpenTherm®’9. Simple room compensated Heating using the Celcia 15 and Priority DHW 1310. Time / Room compensated Heating with Priority DHW (Celcia 20 - Digital clock) 14AVANTA PLUS Combi Options ON / Off Control (Internal modulating)11. Timed heating with constant DHW using external time clock and room thermostat (230v) 1512. Timed heating with constant DHW using internal time clock (230v) and room thermostat (Celcia 10) 16Weather Compensation Control Direct modulating using ‘OpenTherm®’13. External time clock with simple weather compensated Heating and constant DHW 1714. Internal time clock with simple weather compensated Heating and constant DHW 1815. Time / Room compensated Heating using the Celcia 20 (Digital clock) and constant DHW 19Room Compensation Control Direct modulating using ‘OpenTherm®’16. External time clock with simple room compensated Heating using the Celcia 15 and constant DHW 2017. Internal time clock with simple room compensated Heating using the Celcia 15 and constant DHW 2118. Time / Room compensated Heating with Priority DHW (Celcia 20 - Digital clock) 22AVANTA PLUS Underfloor Heating Options (Combi & System)Weather Compensation Control Direct modulating using ‘OpenTherm®’19. System boiler - Internal time clock with simple weather compensated UF Heating and priority DHW 2320. Combi boiler - Internal time clock with simple weather compensated UF Heating and constant DHW 24AVANTA 12v/18v/24v “Open Vented” Options (System only)1. Typical “Y” plan Heating and DHW using 230v controls 252. Typical “W” plan Heating and Priority DHW using 230v controls 263. Typical “S” plan Heating and DHW using 230v controls 27Weather Compensation Control Direct modulating using ‘OpenTherm®’4. Simple weather compensated Heating with Priority DHW 285. Simple weather compensated Heating with 230v room thermostat override and Priority DHW 296. Simple weather compensated Heating with volt free room thermostat override and Priority DHW 302


IMPORTANT NOTE:The layouts illustrated in this brochure are for guidance only and do not constitute a full system design. All Mechanical and Electricalequipment must be installed in accordance with the instructions supplied, by a suitably qualifi ed Engineer and to the currentregulationsControls for the AVANTA PLUS and AVANTA 12v/18v/24v BoilersThe AVANTA series are fully condensing boilers using gas / air ratio controls to provide full modulation and can be operated in thefollowing modes. All boilers require a permanent 230v single phase 3 amp fused power supply plus controls as below:NOTE:The boiler is phase / neutral sensitive when used with external 230v controls.ON / OFF Controlfi xed fl ow temperature where the boiler modulates it’s output to match a fi xed fl ow set point using simple 230v switching controls:• Single or Two channel time clock (internal only available on the 18s/24s/24c/30s/28c/35c/39c)• Room thermostat• Cylinder thermostat• Diverting / mixing or isolating valvesMODULATING Controlfl ow temperature is directly controlled by the outside weather or inside room compensator to provide comfort conditions at all timesusing “OpenTherm®” controls:• Outside sensor• DHW sensor or cylinder thermostat• Room compensator• Digital time/weather or room compensator• Mechanical time/ analogue weather or room compensatorControls available from Broag as optional extras• S62432 Internally mounted two channel digital time clock kit (not for the <strong>Avanta</strong> 12v/18v/24v)• S62432c Internally mounted single channel digital time clock (for the Combi series only)• 50153 Outside sensor• S43946 DHW sensor• S59475 Room thermostat - Celcia 10• S59161 Room compensator - Celcia 15• 58222 Wall mounted Digital Time / Weather compensator - Celcia 20 (outside sensor not included)• TG001 Wall mounted Analog Time / Weather compensator - Theben• DA001 Wall mounted two channel 24 hour time clock (230v switching)• DA002 Wall mounted two channel 7 day time clock (230v switching)• KT806 Wall wireless room thermostat kitTypical controls by others• External mounted simple two channel time clock providing, 230v switched supplies to time control heating and domestic hotwater eg. typical Honeywell ST699 or similar• Cylinder thermostat eg. typical Honeywell L641 or similar• Room thermostat eg. typical Honeywell T6360 or similar• HTG and DHW zone valves c/w a single end switch (closes on valve fully open) eg. Honeywell V4043H or similar• Wiring centre• “Y” / “W” / “S” Plan - complete kits• Other manufacturer’s compatible ‘OpenTherm®’ time and temperature controlsWhen fi tting the diverting valve on a DHW priority system note the orientation of the ports i,e AB, A, and B , they may not beconsistent with the instructions supplied with the valve.3


When using the AVANTA PLUS Combi boiler, DHW is always set for constant operation (not timed) but can if required be changedto allow for time restriction using a two channel time clock. If required the AVANTA series can report a common alarm or boiler runcondition to an external control panel or BMS by using the connections on terminal block X7.Terminals 1 and 2 - Common alarmTerminals 1 and 3 - Boiler run / external gas valve / external pump relayThese are both volt free (max capacity 230v 1 amp ) and are open contacts which close on common alarm or boiler run respectively(see Installation and Technical booklet for futher opions).Pre and After Sales ServiceOur dedicated pre-and-after-sales teams are ready to give you the support you need. It’s an integral part of the quality package thatBroag offers as standard with all products.Contact InformationSales: 0118 9743060After Sales: 0118 9743070Literature: 0118 9743043Training: 0118 9743020Technical: 0118 9743070Spares: 0118 9743070www.avantarange.com4


AVANTA PLUS System Option 1Typical “Y” plan Heating and DHW using 230v controls2 ChannelTime clockRoom Stat230v SupplyWiring Centre22mmReturnCondensate22mmFlow22mm Gas'A' HTGThree way Mid positionvalve - HTG and/orDHW'AB'high output Calorifierthermostat'B' DHWCheck valve maybe necessaryAVS0002WiringCentreL641 CylinderThermostat2CCALL19 10873 4 5 6ST699 ControlLNOFFONOFFONDHWHTGClockCALL2311 2T6360/T4360Room ThermostatRemove exist links123X2BlueG/YellowWhiteGreyOrange'B' DHWLNEELN45X6LN 230vPower SupplyABV4073Mid Position Valve230v - 1 - 503 amp Switched SpurBoilerAVW00025


AVANTA PLUS System Option 2Typical “W” plan Heating and Priority DHW using 230v controls2ChannelTime clockRoom Stat230v SupplyWiring Centre22mmReturnCondensate22mmFlow22mm Gas'A' HTGThree way Divertingvalve - HTG or DHW'AB'high output Calorifierc/w thermostat'B' DHWCheck valve maybe necessaryAVS0003L641 CylinderThermostat2CCALL1WiringCentre9 10873 4 5 6ST699 ControlLNOFFONOFFONDHWHTGClockCALL2311 2T6360/T4360Room ThermostatRemove exist links123X2BlueG/YellowBrownLN45'A' HTG'B' DHWLNEEX6LN 230vPower Supply6ABV4044cDiverting Valve230v - 1 - 503 amp Switched SpurBoilerAVW0003


AVANTA PLUS System Option 3Typical “S” plan Heating and DHW using 230v controls2 ChannelTime clockRoom Stat230v SupplyWiring Centre22mmReturnCondensateHTG Zone Valvec/w end switches22mmFlow22mm GasDHW Zone Valvec/w end switchesCylinder StatAVS0001L641 CylinderThermostat2CCall1WiringCentre9 10873 4 5 6ST699 ControlLNOFFONOFFONDHWHTGClock2Call311 2T6360/T4360Room ThermostatV4043HDHW Zone ValveEnd SwitchClose on fullyopenRemove exist links123X2L4V4043HHTG Zone ValveEnd SwitchCloseonfullyopenLNEEN5X6LN 230vPower Supply230v - 1 - 503 amp Switched SpurBoilerAVW00017


AVANTA PLUS System Option 4Internal time clock - Heating and Priority DHW using Celcia 10 and 3 way diverting valve kit8


AVANTA PLUS System Option 5Simple weather compensated Heating with Priority DHW9


AVANTA PLUS System Option 6Simple weather compensated Heating with room thermostat override (230v) and Priority DHW10


AVANTA PLUS System Option 7Simple weather compensated Heating with room thermostat override (Celcia 10) and Priority DHW11


AVANTA PLUS System Option 8Time / Weather compensated Heating with Priority DHW (Celcia 20 - Digital clock)12


AVANTA PLUS System Option 9Simple room compensated Heating using the Celcia 15 and Priority DHWNOTE:With a 230v switching time clock a frost thermostat, if required, must be connected in parallel with the time clock onterminal strip X2 connectors 1 and 4 (frost stat contacts to close on temperature fall)13


AVANTA PLUS System Option 10Time / Room compensated Heating with Priority DHW (Celcia 20 - Digital clock)14


AVANTA PLUS Combi Option 11Timed heating with constant DHW using external time clock and room thermostat (230v)NOTE:With a 230v switching time clock a frost thermostat, if required, must be connected in parallel with the time clock onterminal strip X2 connectors 1 and 4 (frost stat contacts to close on temperature fall)Two channeltime clockRoom thermostat (230v)Mount in a reference room1.5M above floor away fromany heat scource230v SupplyDHWMains cold waterCondensate22mmFlow22mm Gas22mmReturnAVS0013TerminalBlock X6230v - 3 AmpPower Supply(via switched spur)LNETerminalBlock X5123TerminalBlock X91Exist link2345Exist links678TerminalBlock X21CALL1 2Room thermostat(230v switching)External Time clockTwo channel - 230v switchingONHTG2OFFRemove link1 to 4L34N 5To provide time control over DHWremove link 3/4 in X2 and install wiringfrom time clock (DHW on control) toterminal 3LNONOFFDHW15AVW0013NOTE: Terminal blocks are not in line as shown - diagramatic only


AVANTA PLUS Combi Option 12Timed heating with constant DHW using internal time clock (230v) and room thermostat (Celcia 10)NOTE:With a 230v switching time clock a frost thermostat, if required, must be connected in parallel with the time clock onterminal strip X2 connectors 1 and 4 (frost stat contacts to close on temperature fall)Room thermostat (Celcia 10)Mount in a reference room1.5M above floor away fromany heat scource1020P3230v SupplyDHWMains cold waterCondensate22mmFlow22mm Gas22mmReturnAVS0014TerminalBlock X6L230v - 3 AmpPower Supply(via switched spur)NETerminalBlock X5123TerminalBlock X91Exist link23Exist linkRemoveExist link45678CALL1 2Room thermostat(volt free) ie: Celcia 10TerminalBlock X21234LInternal Time clock - Twin channel230v switching c/w cable and plugNote:Clock has DHW channel disabled for 24hr operation54321CH2 - DHWCH1- HTGNL165Remove ExistPlug from X2NPlug clockinto X2AVW0014NOTE: Terminal blocks are not in line as shown - diagramatic only


AVANTA PLUS Combi Option 13External time clock with simple weather compensated Heating and constant DHWTwo channeltime clockOutside SensorMount in a sheltered positionon North facing wall230v SupplyDHWMains cold waterCondensate22mmFlow22mm Gas22mmReturnAVS0011TerminalBlock X6230v - 3 AmpPower Supply(via switched spur)LNETerminalBlock X512TerminalBlock X93Outside Sensor(red band)1Exist link2345Exist links67TerminalBlock X2812External Time clockTwo channel - 230v switchingONOFFHTGLN345To provide time control over DHWremove link 3/4 in X2 and install wiringfrom time clock (DHW on control) toterminal 3LNONOFFDHWRemove link1 to 4AVW0011NOTE: Terminal blocks are not in line as shown - diagramatic only17


1020AVANTA PLUS Combi Option 14Internal time clock with simple weather compensated Heating and constant DHWOutside SensorMount in a sheltered positionon North facing wallP3230v SupplyMains cold waterDHWCondensate22mmFlow22mm Gas22mmReturnAVS0019TerminalBlock X6L230v - 3 AmpPower Supply(via switched spur)NTerminalBlock X5E12TerminalBlock X93Outside Sensor(red band)1Exist link2345Exist links678TerminalBlock X21234LInternal Time clock - Twin channel230v switching c/w cable and plugNote:Clock has DHW channel disabled for 24hr operation54321CH2 - DHWCH1- HTGNL5Remove ExistPlug from X2NPlug clockinto X218AVW0019NOTE: Terminal blocks are not in line as shown - diagramatic only


AVANTA PLUS Combi Option 15Time / Room compensated Heating using the Celcia 20 (Digital clock) and constant DHWTime / Weathercompensator (Celcia 20)Mount in a reference room1.5M above floor away fromany heat scourceOutside SensorMount in a sheltered positionon North facing wall230v SupplyMains cold waterDHWCondensate22mmFlow22mm Gas22mmReturnAVS0017TerminalBlock X6L230v - 3 AmpPower Supply(via switched spur)NETerminalBlock X512TerminalBlock X93Outside Sensor(red band)1RemoveExist link234Exist linkRemoveExist link5678TerminalBlock X212O-T BusExist linksL34Time/Weather compensatorCelcia 20N5AVW0017NOTE: Terminal blocks are not in line as shown - diagramatic only19


AVANTA PLUS Combi Option 16External time clock with simple room compensated Heating using the Celcia 15 and constant DHWNOTE:With a 230v switching time clock a frost thermostat, if required, must be connected in parallel with the time clock onterminal strip X2 connectors 1 and 4 (frost stat contacts to close on temperature fall)Two channeltime clockModulating thermostat(Celcia 15)Mount in a reference room1.5M above floor away fromany heat scource230v SupplyDHWMains cold waterCondensate22mmFlow22mm Gas22mmReturnAVS0012TerminalBlock X6230v - 3 AmpPower Supply(via switched spur)LNETerminalBlock X5123TerminalBlock X91Exist link234Exist linkRemoveExist link5678TerminalBlock X212ACRoom compensatorCelcia 15External Time clockTwo channel - 230v switchingONOFFHTG203L 4N 5To provide time control over DHWremove link 3/4 in X2 and install wiringfrom time clock (DHW on control) toterminal 3LNONOFFDHWRemove link1 to 4AVW0012NOTE: Terminal blocks are not in line as shown - diagramatic only


1020AVANTA PLUS Combi Option 17Internal time clock with simple room compensated Heating using the Celcia 15 and constant DHWNOTE:With a 230v switching time clock a frost thermostat, if required, must be connected in parallel with the time clock onterminal strip X2 connectors 1 and 4 (frost stat contacts to close on temperature fall)Room compensator(Celcia15)Mount in a reference room1.5M above floor away fromany heat scourceP3230v SupplyDHWMains cold waterCondensate22mmFlow22mm Gas22mmReturnAVS0015TerminalBlock X6L230v - 3 AmpPower Supply(via switched spur)NETerminalBlock X5123TerminalBlock X91Exist link23Room compensatorCelcia 154Exist link56ACRemoveExist link78TerminalBlock X21234LInternal Time clock - Twin channel230v switching c/w cable and plugNote:Clock has DHW channel disabled for 24hr operation54321CH2 - DHWCH1- HTGNL5Remove ExistPlug from X2NPlug clockinto X221AVW0015NOTE: Terminal blocks are not in line as shown - diagramatic only


AVANTA PLUS Combi Option 18Time / Room compensated Heating with Priority DHW (Celcia 20 - Digital clock)Time / Weathercompensator (Celcia 20)Mount in a reference room1.5M above floor away fromany heat scource230v SupplyDHWMains cold waterCondensate22mmFlow22mm Gas22mmReturnAVS0018TerminalBlock X6L230v - 3 AmpPower Supply(via switched spur)NTerminalBlock X5E123TerminalBlock X91RemoveExist link234Exist linkRemoveExist link5678TerminalBlock X212O-T BusExist linksL34Time/Weather compensatorCelcia 20N523AVW0018NOTE: Terminal blocks are not in line as shown - diagramatic only


AVANTA PLUS System Option 19System boiler - Internal time clock with simple weather compensated UF Heating and priority DHWNOTE:High temperature protection and local temperature controls for the under floor heating system not supplied by Broag24


1020AVANTA PLUS Combi Option 20Combi boiler - Internal time clock with simple weather compensated UF Heating and constant DHWNOTE:High temperature protection and local temperature controls for the under floor heating system not supplied by BroagOutside SensorMount in a sheltered positionon North facing wallLocal tempcontrolUnder floor HTGP3230v SupplyMains cold waterDHWLocal tempcontrolCondensate22mmFlow22mmReturn22mm GasHigh Tempdiverting valveUnder floor HTGLow lossheaderSystempumpAVS0020TerminalBlock X6L230v - 3 AmpPower Supply(via switched spur)NETerminalBlock X524RemoveExist linkExist linksTerminalBlock X9TerminalBlock X212345Remove ExistPlug from X2AVW0021LN12312345678Plug clockinto X2Outside Sensor(red band)Internal Time clock - Twin channel230v switching c/w cable and plugNote:Clock has DHW channel disabled for 24hr operationNOTE: Terminal blocks are not in line as shown - diagramatic only54321CH2 - DHWCH1- HTGNL4002 x 1" BSP(F)Boiler side90 x 90 SqSteel tube82.5235 ctrsSuggested design of a low loss headerBroag part No : GL001330 ctrs 352 x 11/2" BSP (System side


AVANTA 12v/18v/24v System Only - Option 1Typical “Y” plan Heating and DHW using 230v controls230v Supply2 ChannelTime clockCheck valve maybe necessaryWiring CentreDHW thermostat'B' DHWRoom Stat22mmFlow'AB''A' HTGThree way Mid positionvalve - HTG and/orDHW22mmReturnCondensateAOVS00222mm GasWiringCentreL641 CylinderThermostat2CCALL19 10873 4 5 6ST699 ControlLNOFFONOFFONDHWHTGClock2CALL311 2N1T6360/T4360Room ThermostatL23X44Remove exist linksSystem PumpMust be wired direct to boilerE123X2'A' HTGBlueG/YellowWhiteGreyOrange'B' DHWLNEELN45X6LN 230vPower SupplyABV4073Mid Position Valve230v - 1 - 503 amp Switched SpurBoilerAOVW00225


AVANTA 12v/18v/24v System Only - Option 2Typical “W” plan Heating and Priority DHW using 230v controls26


AVANTA 12v/18v/24v System Only - Option 3Typical “S” plan Heating and DHW using 230v controlsDHW thermostat230v Supply2 ChannelTime clockCheck valve maybe necessaryWiring CentreDHW Zone valvec/w end switchesRoom Stat22mmFlow22mmReturnHTG Zone valvec/w end switchesCondensate22mm GasAOVS003L641 CylinderThermostat2CCall1WiringCentre9 10873 4 5 6ST699 ControlLNOFFONOFFONDHWHTGClock2Call311 2N1T6360/T4360Room ThermostatL23X4V4043HDHW Zone ValveEnd SwitchClose on fullyopenESystem PumpMust be wired directto boilerRemove exist links4123X2L4V4043HHTG Zone ValveEnd SwitchClose on fullyopenLNEEN5X6LN 230vPower Supply230v - 1 - 503 amp Switched SpurBoilerAOVW00127


AVANTA 12v/18v/24v System Only Option 4Simple weather compensated Heating with Priority DHW28


AVANTA 12v/ 1218v/24v System Only Option 5Simple weather compensated Heating with 230v room thermostat override and Priority DHW29


AVANTA 12v/18v/24vSystem Only Option 6Simple weather compensated Heating with volt free room thermostat override and Priority DHW30


120575-050309The <strong>schematics</strong> in this brochure are for guidance only and do notconstitute a design. The content in this brochure is based on the latestinformation available at date of publication and may be subject torevisions. We reserve the right to continuous development in both designand manufacture, therefore any changes to the technology or equipmentemployed may not be retrospective nor may we be obliged to adjust earliersupplies accordingly.Broag Ltd.Remeha HouseMolly Millars LaneRG41 2QP WOKINGHAM,Berks.© CopyrightAll technical and technological information contained in thesetechnical instructions, as well as any drawings and technicaldescriptions furnished by us remain our property and may not bemultiplied without our prior consent in writing.Tel: +44 118 9783434Fax: +44 118 9786977Internet: uk.remeha.comwww.avantarange.comE-mail: boilers@broag-remeha.com