Product Data SheetEdition 27.01.2009Revision no: 0Identification no:01 09 01 01 124 01 50000<strong>Sikaplan</strong> ® -<strong>SGmA</strong> <strong>1.5</strong> (Trocal ® <strong>SGmA</strong>, <strong>1.5</strong> mm)<strong>Sikaplan</strong> ® -<strong>SGmA</strong> <strong>1.5</strong> (Trocal ® <strong>SGmA</strong>, <strong>1.5</strong>mm)Polymeric sheet for roof waterproofingProductDescriptionUses<strong>Sikaplan</strong> ® -SgmA <strong>1.5</strong> (Trocal ® SgmA, <strong>1.5</strong> mm) is a multi-layer, synthetic roofwaterproofing sheet based on premium-quality polyvinyl chloride (PVC) withinlay of glass non-woven.Roof waterproofing membrane for roofs with ballast (e.g gravel, concreteslabs, green roof (intensive, extensive), terraces with pedestrian traffic):• Loose laid with ballast• Green roofs• Utility roofsRoofingCharacteristics /AdvantagesTests• High resistance to ageing• Resistant to all common environmental influences• High resistance to mechanical influences• Resistant to micro-organisms• High tensile strength• High dimensional stability• Excellent flexibility in cold temperatures• High water vapour permeability• Outstanding weldability• Resistance against weathering during installation period• RecyclableApproval / Standards • Polymeric sheets for roof waterproofing according to <strong>EN</strong> 13956,certified by notified body 1213-CPD-4125/4127 and provided with theCE-mark.• Reaction to fire according to <strong>EN</strong> 13501-1, class E.• Root penetration resistance tested according to FLL-Test Procedure.• Official Quality Approvals and Aggrement Certificates and approvals.• Monitoring and assessment by approved laboratories.• Quality Management system in accordance with <strong>EN</strong> ISO 9001/14001.• Production according to Responsible Care policy of ChemicalIndustry.1 1/6<strong>Sikaplan</strong> ® -<strong>SGmA</strong> <strong>1.5</strong> (Trocal ® <strong>SGmA</strong>, <strong>1.5</strong> mm)


Product DataFormAppearance / ColoursSurface:Colours:Top surface:Bottom surface:slightly structuredbeigebeigePackagingPacking unit:11 or 20 rolls per pallet9 or 15 rolls per palletRoll length:15.00 m20.00 mRoll width:2.00 m2.00 mRoll weight:57.00 kg76.00 kgStorageStorage Conditions /Shelf-LifeRolls must be stored in horizontal position on pallet and protected fromdirect sunlight, rain and snow. Product does not expire during correctstorage.2 2/6<strong>Sikaplan</strong> ® -<strong>SGmA</strong> <strong>1.5</strong> (Trocal ® <strong>SGmA</strong>, <strong>1.5</strong> mm)


Technical DataProduct Declaration <strong>EN</strong> 13956Visible defects Pass <strong>EN</strong> 1850-2Length 15.00 / 20.00 (- 0% / +5 %) m <strong>EN</strong> 1848-2Width 2.00 (- 0.5 % / +1 % ) m <strong>EN</strong> 1848-2Straightness ≤ 30 mm <strong>EN</strong> 1848-2Flatness ≤ 10 mm <strong>EN</strong> 1848-2Effective thickness <strong>1.5</strong> (- 5 % / + 10 % ) mm <strong>EN</strong> 1849-2Mass per unit area 1.9 (- 5 % / + 10 % ) kg/m 2 <strong>EN</strong> 1849-2Water tightness Pass <strong>EN</strong> 1928Effects of liquidchemicals includingwaterOn request<strong>EN</strong> 1847Reaction to fire E <strong>EN</strong> ISO 11925-2, classification after <strong>EN</strong> 13501-1Joint shear resistance ≥ 500 N/50 mm <strong>EN</strong> 12317-2Water vapourtransmission propertiesµ = 20’000<strong>EN</strong> 1931Tensile stress <strong>EN</strong> 12311-2longitudinal (md) * ≥ 9.5 N/mm 2transversal (cmd) * ≥ 8.5 N/mm 2Elongation <strong>EN</strong> 12311-2longitudinal (md) * ≥ 200 %transversal (cmd) * ≥ 200 %Resistance to impact <strong>EN</strong> 12691hard substratesoft substrate≥ 600 mm≥ 1000 mmResistance to static <strong>EN</strong> 12730load soft substraterigid substrateResistance to rootpenetration≥ 20 kg≥ 20 kgPasspr<strong>EN</strong> 13948Dimension stability <strong>EN</strong> 1107-2longitudinal (md) * ≤ │0.3│ %transversal (cmd) * ≤ │0.3│ %Foldability at lowtemperature≤ -25 0 C<strong>EN</strong> 495-5*md =*cmd =machine directioncross machine direction3 3/6<strong>Sikaplan</strong> ® -<strong>SGmA</strong> <strong>1.5</strong> (Trocal ® <strong>SGmA</strong>, <strong>1.5</strong> mm)


SystemInformationSystem StructureAncillary products according to local price list:• <strong>Sikaplan</strong> ® -S <strong>1.5</strong> (Trocal S, <strong>1.5</strong> mm) unreinforced sheet for detailing• <strong>Sikaplan</strong> ® -SG <strong>1.5</strong> (Trocal SG, <strong>1.5</strong> mm) or <strong>Sikaplan</strong> ® -15G roofing sheetfor exposed connections and flashings• Moulded corner pieces, prefabricated corners and pipe flashings• Sika- Trocal Metal Sheet Type S• Sika- Trocal Cleaner 2000• Sika- Trocal Cleaner L 100• Sika- Trocal Welding Agent• Sika- Trocal Seam Sealant• Sika- Trocal C 733 (Contact adhesive)• Sika- Trocal CV 705/733 (Thinner for Sika-Trocal C 733)Application DetailsSubstrate QualityThe substrate surface must be uniform, smooth and free of any sharpprotrusions or burrs, etc.<strong>Sikaplan</strong> ® -<strong>SGmA</strong> <strong>1.5</strong> (Trocal ® <strong>SGmA</strong>, <strong>1.5</strong> mm) must be separated from anyincompatible substrates by an effective separation layer to preventaccelerated ageing. Prevent direct contact with bitumen, tar, fat, oil, solventcontaining materials and other plastic materials, e.g. expanded polystyrene(EPS), extruded polystyrene (XPS), polyurethane (PUR), polyisocyanurate(PIR) or phenolic foam (PF) as this could adversely affect the productproperties.ApplicationConditions /LimitationsTemperatureCompatibilityResistanceThe use of <strong>Sikaplan</strong> ® -<strong>SGmA</strong> <strong>1.5</strong> (Trocal ® <strong>SGmA</strong>, <strong>1.5</strong> mm) membrane islimited to geographical locations with average monthly minimumtemperatures of -25 °C.Permanent ambient temperature during use is limited to +50 °C.Not compatible with direct contact to other plastics, e.g. EPS, XPS, PUR,PIR, PF.Not resistant to tar, bitumen, oil and solvent containing materials.Not applicable for permanent exposure to UV irradiation.4 4/6<strong>Sikaplan</strong> ® -<strong>SGmA</strong> <strong>1.5</strong> (Trocal ® <strong>SGmA</strong>, <strong>1.5</strong> mm)


RoofingApplicationInstructionsApplication Method /ToolsNotes on Application /LimitationsProtective MeasuresTransportation ClassDisposalInstallation procedure:According to the valid installation instructions for <strong>Sikaplan</strong> ® <strong>SGmA</strong> (Trocal ®<strong>SGmA</strong>)-types for ballasted roof system.Fixing Method:Loosely laid and covered with ballast. Mechanical fixing at the roof perimeteris recommended to keep membrane in place.Roof waterproofing sheet is installed by loose laying and covered withballast according to local wind load situation. If ballast weight is insufficientto restrain against wind uplift the membrane may be fixed mechanically inseam overlap or independent from overlap.Welding Method:Overlap seams are welded by electric hot welding equipment, such asmanual hot air welding machines and pressure rollers or automatic hot airwelding machines with controlled hot air temperature capability of minimum600 °C.(Recommended type of equipment: LEISTER TRIAC PID for manual weldingand LEISTER VARIMAT for automatic welding.)Welding parameters including temperature, machine speed, air flow,pressure and machine settings must be evaluated, adapted and checked onsite according to the type of equipment and the climatic situation prior towelding works. The effective width of welded overlaps should be minimum20 mm.If local weather conditions allow cold welding of sheet overlaps with Sika-Trocal Welding Agent, it is permitted for <strong>Sikaplan</strong> ® -<strong>SGmA</strong> <strong>1.5</strong> (Trocal ®<strong>SGmA</strong>, <strong>1.5</strong> mm) system with ballast. The effective width of welded overlapby cold welding must be 30 mm.The seams must be mechanically tested with screw driver or steel needle toensure the integrity/completion of the weld. Any imperfections must berectified by hot air welding.Cold welded seam edges must be sealed by Sika-Trocal Seam Sealant aftertesting.Installation works must be carried out only by Sika ® Roofing instructedcontractors.Temperature limits for the installation of the membrane:Substrate temperature:Ambient temperature :-25 °C min. / +60 °C max. For hot air welding+5 °C min. / +60 °C max. For cold welding-25 °C min. / +60 °C max. For hot air welding+5 °C min. / +60 °C max. For cold weldingInstallation of some ancillary products, e.g. contact adhesives/thinners islimited to temperatures above +5 °C. Please refer to the respective ProductData Sheets.Special measures may be compulsory for installation below +5 °C ambienttemperature due to safety requirements in accordance with nationalregulations.Fresh air ventilation must be ensured when working (welding) in closedrooms. Local safety regulations must be observed.The product is not classified as hazardous good for transport.The material is recyclable. Disposal must be according to local regulations.Please contact your local Sika ® Roofing sales organisation for moreinformation.5 5/6<strong>Sikaplan</strong> ® -<strong>SGmA</strong> <strong>1.5</strong> (Trocal ® <strong>SGmA</strong>, <strong>1.5</strong> mm)


Value BaseAll technical data stated in this Product Data Sheet are based on laboratory tests.Actual measured data may vary due to circumstances beyond our control.Local Restrictions Please note that as a result of specific local regulations the performance of thisproduct may vary from country to country. Please consult the local Product DataSheet for the exact description of the application fields.Health and SafetyInformationLegal NotesFor information and advice on the safe handling, storage and disposal of chemicalproducts, users shall refer to the most recent Material Safety Data Sheet containingphysical, ecological, toxicological and other safety-related data.The information, and, in particular, the recommendations relating to the applicationand end-use of Sika products, are given in good faith based on Sika's currentknowledge and experience of the products when properly stored, handled andapplied under normal conditions in accordance with Sika’s recommendations. Inpractice, the differences in materials, substrates and actual site conditions are suchthat no warranty in respect of merchantability or of fitness for a particular purpose,nor any liability arising out of any legal relationship whatsoever, can be inferredeither from this information, or from any written recommendations, or from any otheradvice offered. The user of the product must test the product’s suitability for theintended application and purpose. Sika reserves the right to change the propertiesof its products. The proprietary rights of third parties must be observed. All ordersare accepted subject to our current terms of sale and delivery. Users must alwaysrefer to the most recent issue of the local Product Data Sheet for the productconcerned, copies of which will be supplied on request.Sika Yapı Kimyasalları A.Ş.Deri Org. San. Böl. 2. Yol J–7Parsel, Aydınlı, Orhanlı Mevkii,34957 Tuzla, İstanbul, TürkiyeÇağrı MerkeziTelefonFaksbilgi@tr.sika.com+90 216 444 74 52+90 216 581 06 00+90 216 581 06 99www.sika.com.tr6 6/6<strong>Sikaplan</strong> ® -<strong>SGmA</strong> <strong>1.5</strong> (Trocal ® <strong>SGmA</strong>, <strong>1.5</strong> mm)