13.07.2015 Views

Report on certificate - Tuv-fs.com

Report on certificate - Tuv-fs.com

Report on certificate - Tuv-fs.com

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

3 Certificati<strong>on</strong> Requirements3.1 Basis of Certificati<strong>on</strong>The certificati<strong>on</strong> of the FSC Versi<strong>on</strong> 710.x will be according to the regulati<strong>on</strong>s and standardslisted in clause 3.3 of this document. This will certify the successful <strong>com</strong>pleti<strong>on</strong> of the followingtest segments:I. Functi<strong>on</strong>al safety Analysis of the system structure (FMEA system) Analysis of the hardware (FMEA <strong>com</strong>p<strong>on</strong>ent, quantitative analysis) Analysis of the software Fault simulati<strong>on</strong>s and software tests Test of the fault preventi<strong>on</strong> measures Functi<strong>on</strong>al testII. Electrical safetyIII. Susceptibility to envir<strong>on</strong>mental errors Climate and temperature Mechanical effectsIV. Electromagnetic <strong>com</strong>patibilityV. Safety informati<strong>on</strong> in the product documentati<strong>on</strong> (safety manual, operating instructi<strong>on</strong>s)VI. Product-related Quality Management in manufacturing and product care.Certificati<strong>on</strong> is dependent <strong>on</strong> successful <strong>com</strong>pleti<strong>on</strong> of all above listed test segments. The testingfollows the basic certificati<strong>on</strong> scheme for Safety Comp<strong>on</strong>ents of TÜV SÜD Rail GmbH.3.2 Certificati<strong>on</strong> Documentati<strong>on</strong>[1] Technical <str<strong>on</strong>g>Report</str<strong>on</strong>g> of Modificati<strong>on</strong>sZ10 09 04 20160 010Fail-Safe C<strong>on</strong>troller System Family, FSC Versi<strong>on</strong> 710.x<str<strong>on</strong>g>Report</str<strong>on</strong>g> No.: HH84600T, Versi<strong>on</strong> 1.0, dated 2012-10-17 related toTechnical <str<strong>on</strong>g>Report</str<strong>on</strong>g>: HH80661T[2] Technical <str<strong>on</strong>g>Report</str<strong>on</strong>g>Fail-Safe C<strong>on</strong>troller System Family, FSC Versi<strong>on</strong> 710.x<str<strong>on</strong>g>Report</str<strong>on</strong>g> No HH84624T, Versi<strong>on</strong> 1.0 of 5. February 2013[3] <str<strong>on</strong>g>Report</str<strong>on</strong>g> of the type approval of the Safety Manager R150.1<str<strong>on</strong>g>Report</str<strong>on</strong>g>-No.: 968/EZ 195.18/12 of 13. August 2012Certificati<strong>on</strong> report <strong>on</strong> the most recently tested versi<strong>on</strong>:[4] <str<strong>on</strong>g>Report</str<strong>on</strong>g> to the CertificateFSC Fail-Safe C<strong>on</strong>troller System FamilyVersi<strong>on</strong> 710.x<str<strong>on</strong>g>Report</str<strong>on</strong>g> no. SH99495C Revisi<strong>on</strong> 7.10 of 14. March 2011TÜV SÜD Rail GmbH 717506225Generic Safety Systems HH84623C_Rev1.0.docx / Rev. 1.0Barthstraße 16 • D-80339 Munich • GermanyAuthor: Martin BraunPh<strong>on</strong>e: +49 (89) 5190 -2899, Fax: -2933 05.02.2013E-Mail: martin.braun@tuev-sued.de Page 24 of 33

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!