13.07.2015 Views

Report on certificate - Tuv-fs.com

Report on certificate - Tuv-fs.com

Report on certificate - Tuv-fs.com

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

5.4.3. The use of safety-related Counter Functi<strong>on</strong>ality is suitable for processes in which thecounter signal is changing within the sec<strong>on</strong>d-fault occurrence time. The planning andprogramming of the counter functi<strong>on</strong>ality shall <strong>com</strong>ply with the manual „Fail Safe C<strong>on</strong>trol,Technical Note, FSC Safety-Related Counter Functi<strong>on</strong>ality“.5.5 Communicati<strong>on</strong>; Product-Related C<strong>on</strong>diti<strong>on</strong>s5.5.1. Safety-related <strong>com</strong>municati<strong>on</strong> (FSC protocol) is <strong>on</strong>ly permitted within the Fail-SafeC<strong>on</strong>troller System Family.5.5.2. For safety-related <strong>com</strong>municati<strong>on</strong>, the safe c<strong>on</strong>diti<strong>on</strong> for transmissi<strong>on</strong> data shall be “zero”.5.5.3. To establish safety related <strong>com</strong>municati<strong>on</strong> via public tele<strong>com</strong>municati<strong>on</strong> services themodified RKE 3964R protocol may be used also but extra measures for data integrity mustbe programmed via FSC logic functi<strong>on</strong>s and must fulfill the requirements according SIL 2(see also chapter 2.6.2). This is realised with the following modules which must be usedfor the safety relevant <strong>com</strong>municati<strong>on</strong>:- MASTER_1, FIRST ISSUE, 07-26-1998- SLAVE_62, FIRST ISSUE, 07-26-19985.6 Special Operating Modes; N<strong>on</strong>-Product-Related C<strong>on</strong>diti<strong>on</strong>s5.6.1. Modificati<strong>on</strong>s during active operati<strong>on</strong> (<strong>on</strong>-line modificati<strong>on</strong>s) are permissible <strong>on</strong>ly afterc<strong>on</strong>sultati<strong>on</strong> with the inspecti<strong>on</strong> and testing centre resp<strong>on</strong>sible for approval of theapplicati<strong>on</strong>.5.6.2. Resp<strong>on</strong>sibility for m<strong>on</strong>itoring the process while <strong>on</strong>-line modificati<strong>on</strong>s are being carried outis that of the pers<strong>on</strong> resp<strong>on</strong>sible for the <strong>on</strong>-line modificati<strong>on</strong>s. All system messagesreceived while carrying out <strong>on</strong>-line modificati<strong>on</strong>s are to be treated with the utmost cauti<strong>on</strong>.5.6.3. On-line modificati<strong>on</strong>s presuppose applicati<strong>on</strong>s programs that have been subjected toparticularly thorough testing beforehand, e.g. at simulators. In the case of such thoroughlytested applicati<strong>on</strong> programs, as part of the <strong>on</strong>-line modificati<strong>on</strong> process, at least allfuncti<strong>on</strong>s reported by the functi<strong>on</strong> “Verify FSC Applicati<strong>on</strong> Software“ of the FSC Navigatoras having been modified shall be subjected to a full functi<strong>on</strong> test.The operator shall <strong>com</strong>pare all changes reported during the process of <strong>on</strong>-linemodificati<strong>on</strong> with the modificati<strong>on</strong>s he/she has made and investigate any discrepancies(i.e. apparently unmodified applicati<strong>on</strong> sheet reported as having been modified) anddocument the causes.5.6.4. The use of "maintenance override" shall <strong>com</strong>ply with the current versi<strong>on</strong> of the document"Maintenance Override" published by TÜV SÜD and TÜV Rheinland.5.6.5. Forcing of signals shall <strong>on</strong>ly be possible allowed under the supervisi<strong>on</strong> of a key-operatedswitch and is the resp<strong>on</strong>sibility of the operator al<strong>on</strong>e. Checking of which signals may beforced can be performed with the aid of a printout of the FSC variables.5.6.6. If the user program is stored in RAM or Flash, inadvertent alterati<strong>on</strong> of the user programshall be prevented by means of password protecti<strong>on</strong>.5.7 Special Operating Modes; Product-Related C<strong>on</strong>diti<strong>on</strong>sN<strong>on</strong>eTÜV SÜD Rail GmbH 717506225Generic Safety Systems HH84623C_Rev1.0.docx / Rev. 1.0Barthstraße 16 • D-80339 Munich • GermanyAuthor: Martin BraunPh<strong>on</strong>e: +49 (89) 5190 -2899, Fax: -2933 05.02.2013E-Mail: martin.braun@tuev-sued.de Page 31 of 33

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!