SUPPLY AND RETURN PIPING2. See Figure #8 for typical piping for domestic hot waterheater.• Automatic mixing valve must be installed on tanklessheater outlet. Install per valve manufacturer'sinstructions.• Install adjustable flow restrictor in cold water inletdue to varying water conditions.3. See Figures #9 and #10 for the suggested piping fora modular steam boiler.! DANGERWater temperatures exceeding 125°F will causesevere burns instantly or death by scalding.Figure #8PIPING FOR BUILT-INDOMESTIC HOT WATER HEATERUNTEMPEREDHOT WATERUNTEMPERED HOT WATER TOAUTOMATIC WASHERTEMPERING VALVEINSTALLED BELOW CENTERLINE OF BOILER HOTCONNECTIONFLOWCONTROLREGULATORDOMESTICHOT WATERT & P VALVECOLD WATERCOLD WATER IN10