13.07.2015 Views

Calibration for the Sensitivity Matrix of the Collins Strain Gauge ...

Calibration for the Sensitivity Matrix of the Collins Strain Gauge ...

Calibration for the Sensitivity Matrix of the Collins Strain Gauge ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

DSTO-TN-0583Page classification: UNCLASSIFIEDDEFENCE SCIENCE AND TECHNOLOGY ORGANISATIONDOCUMENT CONTROL DATA1. PRIVACY MARKING/CAVEAT (OF DOCUMENT)2. TITLE<strong>Calibration</strong> <strong>for</strong> <strong>the</strong> <strong>Sensitivity</strong> <strong>Matrix</strong> <strong>of</strong> <strong>the</strong> <strong>Collins</strong> <strong>Strain</strong> <strong>Gauge</strong>Balance4. AUTHOR(S)Adam Bland<strong>for</strong>d3. SECURITY CLASSIFICATION (FOR UNCLASSIFIED REPORTSTHAT ARE LIMITED RELEASE USE (L) NEXT TO DOCUMENTCLASSIFICATION)DocumentTitleAbstract5. CORPORATE AUTHOR(U)(U)(U)Plat<strong>for</strong>ms Sciences Laboratory506 Lorimer StFishermans Bend Victoria 3207 Australia6a. DSTO NUMBERDSTO-TN-05836b. AR NUMBERAR-013-2096c. TYPE OF REPORTTechnical Note7. DOCUMENT DATESeptember 20048. FILE NUMBER2003/482479. TASK NUMBERRDI 01/25510. TASK SPONSORRDI11. NO. OF PAGES2012. NO. OF REFERENCES313. URL on <strong>the</strong> World Wide Web14. RELEASE AUTHORITYhttp://www.dsto.defence.gov.au/corporate/reports/DSTO-TN-0583.pdfChief, Air Vehicles Division15. SECONDARY RELEASE STATEMENT OF THIS DOCUMENTApproved <strong>for</strong> public releaseOVERSEAS ENQUIRIES OUTSIDE STATED LIMITATIONS SHOULD BE REFERRED THROUGH DOCUMENT EXCHANGE, PO BOX 1500, EDINBURGH, SA 511116. DELIBERATE ANNOUNCEMENTNo Limitations17. CITATION IN OTHER DOCUMENTS Yes18. DEFTEST DESCRIPTORScalibration, strain gauges, balances, wind tunnels, low speed wind tunnels, loads (<strong>for</strong>ces), matrices (ma<strong>the</strong>matics), data acquisition,computer programs19. ABSTRACTDSTO operates a low speed wind tunnel within <strong>the</strong> Air Vehicles Division <strong>of</strong> <strong>the</strong> Plat<strong>for</strong>ms Sciences Laboratory.Air speeds up to approximately 90 m/s can be produced in <strong>the</strong> test section which is 2.7 m wide by 2.1 m high.A six-component <strong>Collins</strong> internal strain-gauge balance is used to measure <strong>for</strong>ces and moments on a modelunder test. A manual calibration <strong>of</strong> this balance has been carried out to determine <strong>the</strong> sensitivity matrix <strong>for</strong> <strong>the</strong>new amplifiers and wiring system integrated into <strong>the</strong> low speed wind tunnel data acquisition system followingits upgrade in 2000. With <strong>the</strong> new sensitivity matrix <strong>the</strong> maximum standard error <strong>of</strong> <strong>the</strong> loads measured by <strong>the</strong>strain-gauge balance was 0.19%.Page classification: UNCLASSIFIED

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!